Search NASA⌕ Search

SEARCH · Search NASA

Results for “source configuration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Planned Use of Pulsed Crab Cavities for Short X-Ray Pulse Generation at the Advanced Photon Source

Recently, we have explored application to the Advanced Photon Source (APS) of Zholents'[1] crab cavity scheme for production of short x-ray pulses. We assumed use of superconducting (SC) cavities in order to have a continuous stream of crabbed bunches and flexibility of operating modes. The challenges of the SC approach are related to the size, cost, and development time of the cavities and associated systems. A good case can be made [2] for a pulsed system using room-temperature cavities. APS has elected to pursue such a system in the near term, with the SC-based system planned for a later date. This paper describes the motivation for the pulsed system and gives an overview of the planned implementation and issues. Among these are overall configuration options and constraints, cavity design options, frequency choice, cavity design challenges, tolerances, instabilities, and diagnostics plans.

43 PARTICLE ACCELERATORS↗

Formation of a pinched electron beam and an intense x-ray source in radial foil rod-pinch diodes

Low-impedance rod-pinch diode experiments were performed on the MIG generator at Institute of High Current Electronics using an aluminum foil placed between concentric electrodes of a rod-pinch diode. The J × B force accelerates the foil plasma in the axial and radial directions. After the foil plasma is pushed beyond the tip of the rod, a vacuum gap and a pinched electron beam form. The anode and cathode plasmas expansion and the following plasmas sweeping up by the J × B force can result in repetitive gap formations and closures, which are evident in the several successive intense x-ray pulses. A 0.7-mm-size point-like x-ray source was realized using a 1-mm-diameter tungsten rod, tapered to a point over the last 10 mm. The results of experiments show that the foil-shorted rod-pinch diode configuration has the potential to form low-impedance diodes, to shorten x-ray pulse duration and to realize submillimeter spot-size x-ray sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Milky Way as a Kiloparsec-Scale Axionscope

Very high energy gamma-rays are expected to be absorbed by the extragalactic background light over cosmological distances via the process of electron-positron pair production. Recent observations of cosmologically distant gamma-ray emitters by ground based gamma-ray telescopes have, however, revealed a surprising degree of transparency of the universe to very high energy photons. One possible mechanism to explain this observation is the oscillation between photons and axion-like-particles (ALPs). Here we explore this possibility further, focusing on photon-ALP conversion in the magnetic fields in and around gamma-ray sources and in the magnetic field of the Milky Way, where some fraction of the ALP flux is converted back into photons. We show that this mechanism can be efficient in allowed regions of the ALP parameter space, as well as in typical configurations of the Galactic Magnetic Field. As case examples, we consider the spectrum observed from two HESS sources: 1ES1101-232 at redshift z = 0.186 and H 2356-309 at z = 0.165. We also discuss features of this scenario which could be used to distinguish it from standard or other exotic models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gamma ray astrophysics, the extragalactic background light, and new physics

Very high energy gamma-rays are expected to be absorbed by the extragalactic background light over cosmological distances via the process of electron-positron pair production. However, recent observations of cosmologically distant emitters by ground based gamma-ray telescopes might be indicative of a higher-than-expected degree of transparency of the universe. One mechanism to explain this observation is the oscillation between photons and axion-like-particles (ALPs). Here we explore this possibility, focusing on photon-ALP conversion in the magnetic fields in and round gamma-ray sources and in the magnetic field of the Milky Way, where some fraction of the ALP flux is converted back into photons. We show that this mechanism can be efficient in allowed regions of the ALP parameter space, as well as in typical configurations of the Galactic Magnetic Field. As case example, we consider the spectrum observed from a HESS source. We also discuss features of this scenario which could be used to distinguish it from standard or other exotic models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Open‐Source Anaerobic Digestion Modeling Platform, Anaerobic Digestion Model No. 1 Fast (ADM1F)

An open‐source modeling platform, called Anaerobic Digestion Model No. 1 Fast (ADM1F), is introduced to achieve fast and numerically stable simulations of anaerobic digestion processes. ADM1F is compatible with an iPython interface to facilitate model configuration, simulation, data analysis, and visualization. Faster simulations and more stable results are accomplished by implementing an advanced open‐source library of numerical methods called Portable Extensive Toolkit for Scientific Computation (PETSc) to solve the ADM1 system of equations. Leveraging PETSc, ADM1F can consistently complete a steady‐state simulation under 0.2 s, over 99% faster than a benchmark ADM1 model implemented with MATLAB while achieving agreement of model outputs within 1% of those obtained with the benchmark model. For dynamic simulations, however, ADM1F has a computational speed advantage only when the influent characteristics update more frequently than every 4 h. The ability of ADM1F to be useful as a tool to study anaerobic digestion systems is demonstrated through two example implementations of ADM1F: (1) a two‐phase co‐digestion scenario evaluating the impact of the organic loading rate and the substrate composition on reactor performance and stability, and (2) a conventional digester scenario assessing the effectiveness of recovery strategies after disruptions that led to instability. These examples demonstrate how the high simulation speed and the convenience of the iPython interface allow ADM1F to complete complex analyses within minutes, much faster than computational strategies currently reported in the literature.

anaerobic co-digestion↗

Improvement of a plasma uniformity of the 2nd ion source of KSTAR neutral beam injector

The 2nd ion source of KSTAR (Korea Superconducting Tokamak Advanced Research) NBI (Neutral Beam Injector) had been developed and operated since last year. A calorimetric analysis revealed that the heat load of the back plate of the ion source is relatively higher than that of the 1st ion source of KSTAR NBI. The spatial plasma uniformity of the ion source is not good. Therefore, we intended to identify factors affecting the uniformity of a plasma density and improve it. We estimated the effects of a direction of filament current and a magnetic field configuration of the plasma generator on the plasma uniformity. We also verified that the operation conditions of an ion source could change a uniformity of the plasma density of an ion source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Roper Resonance in 2+1 Flavor QCD

The low-lying even-parity states of the nucleon are explored in lattice QCD using the PACS-CS collaboration 2+1-flavor dynamical-QCD gauge-field configurations. The established correlation-matrix approach is used, in which various fermion source and sink smearings are utilized to provide an effective basis of interpolating fields to span the space of low-lying energy eigenstates. Of particular interest is the nature of the first excited state of the nucleon, the N(1/2){sup +} Roper resonance of P{sub 11} pion-nucleon scattering. The Roper state of the present analysis approaches the physical mass, displaying significant chiral curvature at the lightest quark mass. These full QCD results, providing the world's first insight into the nucleon mass spectrum in the light-quark regime, are significantly different from those of quenched QCD and provide interesting insights into the dynamics of QCD.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optical Design of VLS-PGM Soft X-Ray Beamline on Indus-2

The optical design of a soft x-ray beamline on the bending magnet of Indus-2 synchrotron source is presented. A Varied Line Spacing Plane Grating Monochromator (VLS-PGM) was adopted with Hettrick type optics. The VLS-PGM consists of a spherical mirror and three interchangeable gratings of line densities 1200 l/mm, 400 l/mm and 150 l/mm to efficiently cover the energy region 50-1500 eV. The VLS groove parameters were obtained by minimizing defocus aberration, coma and spherical aberration. The overall performance of the beamline was estimated by detailed raytracing calculations. The beamline design, results of the raytracing calculations and the expected performances are presented.

43 PARTICLE ACCELERATORS↗

Optimizing Laser-accelerated Ion Beams for a Collimated Neutron Source

High-flux neutrons for imaging and materials analysis applications have typically been provided by accelerator- and reactor-based neutron sources. A novel approach is to use ultraintense (>1018W/cm2) lasers to generate picosecond, collimated neutrons from a dual target configuration. In this article, the production capabilities of present and upcoming laser facilities are estimated while independently maximizing neutron yields and minimizing beam divergence. A Monte-Carlo code calculates angular and energy distributions of neutrons generated by D-D fusion events occurring within a deuterated target for a given incident beam of D+ ions. Tailoring of the incident distribution via laser parameters and microlens focusing modifies the emerging neutrons. Projected neutron yields and distributions are compared to conventional sources, yielding comparable on-target fluxes per discharge, shorter time resolution, larger neutron energies and greater collimation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

HIREGS observations of the Galactic center and Galactic plane: Separation of the diffuse Galactic hard X-ray continuum from the point source spectra

The balloon-borne high resolution gamma ray and X-ray germanium spectrometer (HIREGS) was used to observe the Galactic center and two positions along the Galactic plane from Antarctica in January 1995. For its flight, the collimators were configured to measure the Galactic diffuse hard X-ray continuum between 20 and 200 keV by directly measuring the point source contributions to the wide field of view flux for subtraction. The hard X-ray spectra of GX 1+4 and GRO J1655-40 were measured with the diffuse continuum subtracted off. The analysis technique for source separation is discussed and the preliminary separated spectra for these point sources and the Galactic diffuse emission are presented.

Boggs, S. E.↗

The development and evaluation of a medical imaging training immersive environment

A novel realistic 3D virtual reality (VR) application has been developed to allow medical imaging students at Queensland University of Technology to practice radiographic techniques independently outside the usual radiography laboratory. A flexible agile development methodology was used to create the software rapidly and effectively. A 3D gaming environment and realistic models were used to engender presence in the software while tutor-determined gold standards enabled students to compare their performance and learn in a problem-based learning pedagogy. Students reported high levels of satisfaction and perceived value and the software enabled up to 40 concurrent users to prepare for clinical practice. Student feedback also indicated that they found 3D to be of limited value in the desktop version compared to the usual 2D approach. A randomised comparison between groups receiving software-based and traditional practice measured performance in a formative role play with real equipment. The results of this work indicated superior performance with the equipment for the VR trained students (P = 0.0366) and confirmed the value of VR for enhancing 3D equipment-based problem-solving skills. Students practising projection techniques virtually performed better at role play assessments than students practising in a traditional radiography laboratory only. The application particularly helped with 3D equipment configuration, suggesting that teaching 3D problem solving is an ideal use of such medical equipment simulators. Ongoing development work aims to establish the role of VR software in preparing students for clinical practice with a range of medical imaging equipment.

07 ISOTOPE AND RADIATION SOURCES↗

Impact of static magnetic fields on the radial line slot antenna plasma source

The radial line slot antenna plasma source is used in semiconductor device fabrication. As is the case for all plasma sources, ever more strict uniformity control requirements are driven by the precision demands of new device technologies. Large volume diffusion plasmas, of which the radial line slot antenna source is one type, must overcome transport effects or diffusion modes that tend to 'center peak' the plasma density near the wafer being processed. One way to resolve problematic transport effects is the insertion of magnetic fields into the plasma region. In this paper, the impact of the magnetic field on plasma properties is parameterized as a function of slot configuration. The magnetic field orientation and the magnitude of magnetic field are varied in a computational study in which the source is modeled as a two-dimensional axisymmetric quasineutral plasma. This work employs a finite element model simulation. The magnitude of magnetic fields considered is 50 Gauss maximum with a microwave power of 3000 W at a pressure of 20 mTorr. 20 mTorr is chosen as this is a condition where diffusion effects are challenging to counteract. The study showed that there are specific conditions for slot configuration and magnetic field that improve the plasma controllability and some that do not. Plasma property modulation is most effective when the plasma source region is placed at large radius with axial magnetic fields. There are synergistic effects between the slot location and magnetic field that are important and placing large magnetic fields at the chamber edge alone does not result in improved uniformity. Electron cyclotron resonance (ECR) heating and the impact of pulsing the magnetic fields are presented. ECR heating is not important for the conditions relevant to this paper and pulsing is shown to have benefit.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Three-dimensional photogrammetric measurement of magnetic field lines in the WEGA stellarator

The magnetic confinement of plasmas in fusion experiments can significantly degrade due to perturbations of the magnetic field. A precise analysis of the magnetic field in a stellarator-type experiment utilizes electrons as test particles following the magnetic field line. The usual fluorescent detector for this electron beam limits the provided information to two-dimensional cut views at certain toroidal positions. However, the technique described in this article allows measuring the three-dimensional structure of the magnetic field by means of close-range photogrammetry. After testing and optimizing the main diagnostic components, measurements of the magnetic field lines were accomplished with a spatial resolution of 5 mm. The results agree with numeric calculations, qualifying this technique as an additional tool to investigate magnetic field configurations in a stellarator. For a possible future application, ways are indicated on how to reduce experimental error sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Parallelizing AT with MatlabMPI

The Accelerator Toolbox (AT) is a high-level collection of tools and scripts specifically oriented toward solving problems dealing with computational accelerator physics. It is integrated into the MATLAB environment, which provides an accessible, intuitive interface for accelerator physicists, allowing researchers to focus the majority of their efforts on simulations and calculations, rather than programming and debugging difficulties. Efforts toward parallelization of AT have been put in place to upgrade its performance to modern standards of computing. We utilized the packages MatlabMPI and pMatlab, which were developed by MIT Lincoln Laboratory, to set up a message-passing environment that could be called within MATLAB, which set up the necessary pre-requisites for multithread processing capabilities. On local quad-core CPUs, we were able to demonstrate processor efficiencies of roughly 95% and speed increases of nearly 380%. By exploiting the efficacy of modern-day parallel computing, we were able to demonstrate incredibly efficient speed increments per processor in AT's beam-tracking functions. Extrapolating from prediction, we can expect to reduce week-long computation runtimes to less than 15 minutes. This is a huge performance improvement and has enormous implications for the future computing power of the accelerator physics group at SSRL. However, one of the downfalls of parringpass is its current lack of transparency; the pMatlab and MatlabMPI packages must first be well-understood by the user before the system can be configured to run the scripts. In addition, the instantiation of argument parameters requires internal modification of the source code. Thus, parringpass, cannot be directly run from the MATLAB command line, which detracts from its flexibility and user-friendliness. Future work in AT's parallelization will focus on development of external functions and scripts that can be called from within MATLAB and configured on multiple nodes, while expending minimal communication overhead with the integrated MATLAB library.

43 PARTICLE ACCELERATORS↗

Numerical weather prediction in low latitudes

Based on the results of a number of numerical prediction experiments, the differential heating between land and ocean is an important and critical factor for investigation of phenomenon such as the onset of monsoons over the Indian subcontinent. The pre-onset period during the month of May shows a rather persistent flow field in the monsoon region. At low levels the circulation exhibits anticyclonic excursions over the Arabian Sea, flowing essentially parallel to the west coast of India from the north. Over the Indian subcontinent the major feature is a shallow heat low over northern India. As the heat sources commence a rapid northwestward movement toward the southern edge of the Tibetan Plateau, an interesting configuration of the large-scale divergent circulation occurs. A favorable configuration for a rapid exchange of energy from the divergent to the rotational kinetic energy develops. Strong low level monsoonal circulations evolve, attendant with that the onset of monsoon rains occurs. In order to test this observational sequence, a series of short-range numerical prediction experiments were initiated to define the initial heat sources.

Krishnamurti, T. N.↗

Detection of Anomalous Gamma-Ray Spectra for On-Site Inspection

This work aims to solve some of the technical and logistical challenges inherent in performing On Site Inspection activities under the authority of the Comprehensive Nuclear-Test-Ban Treaty. Inspectors require equipment that can reliably identify the radionuclide signatures of nuclear test explosions amid a background of environmental contamination. Detection of these radiation anomalies by mobile search teams in the air or on the ground can narrow the search field and target specific areas for more detailed inspection or sampling. The need to protect confidential information of the inspected State Party, especially regarding past nuclear testing activities, suggests that full access to measured gamma-ray spectra should be limited. Spectral blinding techniques---in which only a fraction of the information derived from the spectra is displayed and stored---have the potential to meet the needs of both the OSI team and the State Party. In this paper, we describe one such algorithm that we have developed for identifying anomalous spectra from handheld, mobile, or aerial sensors. The algorithm avoids potential sensitivities by reducing the gamma-ray spectrum into a single number that is displayed and stored. A high value indicates that the spectrum is anomalous. The proposed technique does not rely on identifying specific radionuclides, operates well in the presence of high background variability, and can be configured to ignore specific spectral components. In previous work, the algorithm has proven very effective in classifying gamma-ray spectra as anomalous or not, even with poor statistical information. We performed a limited simulation of an airborne search scenario to demonstrate the potential algorithm for OSI missions. The technique successfully detected an injected source of interest whose count rate was an order of magnitude below background levels. We also configured the algorithm to ignore 137Cs as irrelevant to the mission. The resulting alarm metrics were unaffected by the presence of injected 137Cs contamination.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

w22_laser_radiography - Laser-Based MeV Radiography

This project seeks to develop novel x-ray sources based on high-power short-pulse lasers with unique advantages, including small spot size, flexible configuration, and tailorable spectra. Kinetic plasma simulations using the VPIC particle in cell code will be performed to support the R&D goals of this project. If successful, this effort will allow LANL to deploy flexible, compact x-ray sources for static tomographic radiography and dynamic multi-axis radiography at our firing sites and facilities such as pRad and U1a. The higher resolution, shorter pulse duration, and tunability of our proposed sources will enable new applications in the weapons program and broader scientific community. This effort advances the LANL FY22 Strategic Investment Plan priority of “[r]adiographic tools for dynamic and static imaging with improved spatial and temporal resolution, sensitivity, and dose.”

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct comparison of wire, foil, and hybrid X-pinches on a 200 kA, 150 ns current driver

Wire X-pinches (WXPs) have been studied comprehensively as fast (~1 ns pulse width), small (~1 μm) x-ray sources, created by twisting two or more fine wires into an “X” to produce a localized region of extreme magnetic pressure at the cross-point. Recently, two alternatives to the traditional WXP have arisen: the hybrid X-pinch (HXP), composed of two conical electrodes bridged by a thin wire or capillary, and the laser-cut foil X-pinch (LCXP), cut from a thin foil using a laser. We present a comparison of copper wire, hybrid, and laser-cut foil X-pinches on a single experimental platform: UC San Diego’s ~200 kA, 150 ns rise time GenASIS driver. All configurations produced 1–2 ns pulse width, ≤5 μm soft x-ray (Cu L-shell, ~1 keV) sources (resolutions diagnostically limited) with comparable fluxes. WXP results varied with linear mass and wire count, but consistently showed separate pinch and electron-beam-driven sources. LCXPs produced the brightest (~1 MW), smallest (≤5 μm) Cu K-shell sources, and spectroscopic data showed both H-like Cu K α lines indicative of source temperatures ≥2 keV, and cold K α (~8050 eV) characteristic of electron beam generated sources, which were not separately resolved on other diagnostics (within 1–2 ns and ≤200 μm). HXPs produced minimal K-shell emission and reliably single, bright, and small L-shell sources after modifications to shape the early current pulse through them. Benefits and drawbacks for each configuration are discussed to provide potential X-pinch users with the information required to choose the configuration best suited to their needs.

42 ENGINEERING↗