Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface contamination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,567 records · Page 87

Selective deuterium ion acceleration using the Vulcan petawatt laser

We report on the successful demonstration of selective acceleration of deuterium ions by target-normal sheath acceleration (TNSA) with a high-energy petawatt laser. TNSA typically produces a multi-species ion beam that originates from the intrinsic hydrocarbon and water vapor contaminants on the target surface. Using the method first developed by Morrison et al. [Phys. Plasmas 19, 030707 (2012)], an ion beam with >99% deuterium ions and peak energy 14 MeV/nucleon is produced with a 200 J, 700 fs, >10{sup 20}W/cm{sup 2} laser pulse by cryogenically freezing heavy water (D{sub 2}O) vapor onto the rear surface of the target prior to the shot. Within the range of our detectors (0°–8.5°), we find laser-to-deuterium-ion energy conversion efficiency of 4.3% above 0.7 MeV/nucleon while a conservative estimate of the total beam gives a conversion efficiency of 9.4%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Iron plasma generation using a Nd:YAG laser pulse of several hundred picoseconds

We investigated the high intensity plasma generated by using a Nd:YAG laser to apply a laser-produced plasma to the direct plasma injection scheme. The capability of the source to generate high charge state ions strongly depends on the power density of the laser irradiation. Therefore, we focused on using a higher power laser with several hundred picoseconds of pulse width. The iron target was irradiated with the pulsed laser, and the ion current of the laser-produced iron plasma was measured using a Faraday cup and the charge state distribution was investigated using an electrostatic ion analyzer. We found that higher charge state iron ions (up to Fe{sup 21+}) were obtained using a laser pulse of several hundred picoseconds in comparison to those obtained using a laser pulse of several nanoseconds (up to Fe{sup 19+}). We also found that when the laser irradiation area was relatively large, the laser power was absorbed mainly by the contamination on the target surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effect of the MgO buffer layer thickness on magnetic anisotropy in MgO/Fe/Cr/MgO buffer/MgO(001)

The relationship between the magnetic properties and MgO buffer layer thickness d was studied in epitaxial MgO/Fe(t)/Cr/MgO(d) layers grown on MgO(001) substrate in which the Fe thickness t ranged from 0.4 nm to 1.1 nm. For 0.4 nm ≤ t ≤ 0.7 nm, a non-monotonic coercivity dependence on the MgO buffer thickness was shown by perpendicular magneto-optic Kerr effect magnetometry. For thicker Fe films, an increase in the buffer layer thickness resulted in a spin reorientation transition from perpendicular to the in-plane magnetization direction. Possible origins of these unusual behaviors were discussed in terms of the suppression of carbon contamination at the Fe surface and changes in the magnetoelastic anisotropy in the system. These results illustrate a method to control magnetic anisotropy in MgO/Fe/Cr/MgO(d) via an appropriate choice of MgO buffer layer thickness d.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reducing field emission in superconducting cavities with ozone

Contaminations on the active surface of high-power microwave resonators, such as radio-frequency accelerator cavities, can greatly enlarge electron field emission and reduce their performance. In this work, we demonstrate the use of ozone to clean the surface of niobium superconducting radio-frequency cavities resulting in reduced field emission and enhanced accelerating gradient before onset of field emission. We report results from processing four cavities.

43 PARTICLE ACCELERATORS↗

Measurement of neutron dose equivalent outside and inside of the treatment vault of GRID therapy

Purpose: To evaluate the neutron and photon dose equivalent rates at the treatment vault entrance (H{sub n,D} and H{sub G}), and to study the secondary radiation to the patient in GRID therapy. The radiation activation on the grid was studied.Methods: A Varian Clinac 23EX accelerator was working at 18 MV mode with a grid manufactured by .decimal, Inc. The H{sub n,D} and H{sub G} were measured using an Andersson–Braun neutron REM meter, and a Geiger Müller counter. The radiation activation on the grid was measured after the irradiation with an ion chamber γ-ray survey meter. The secondary radiation dose equivalent to patient was evaluated by etched track detectors and OSL detectors on a RANDO{sup ®} phantom.Results: Within the measurement uncertainty, there is no significant difference between the H{sub n,D} and H{sub G} with and without a grid. However, the neutron dose equivalent to the patient with the grid is, on average, 35.3% lower than that without the grid when using the same field size and the same amount of monitor unit. The photon dose equivalent to the patient with the grid is, on average, 44.9% lower. The measured average half-life of the radiation activation in the grid is 12.0 (±0.9) min. The activation can be categorized into a fast decay component and a slow decay component with half-lives of 3.4 (±1.6) min and 15.3 (±4.0) min, respectively. There was no detectable radioactive contamination found on the surface of the grid through a wipe test.Conclusions: This work indicates that there is no significant change of the H{sub n,D} and H{sub G} in GRID therapy, compared with a conventional external beam therapy. However, the neutron and scattered photon dose equivalent to the patient decrease dramatically with the grid and can be clinical irrelevant. Meanwhile, the users of a grid should be aware of the possible high dose to the radiation worker from the radiation activation on the surface of the grid. A delay in handling the grid after the beam delivery is suggested.

61 RADIATION PROTECTION AND DOSIMETRY↗

HE Production Update at JLab - Introducing an Enhanced Nitrogen Purge for Clean String Assembly

A major limitation to cryomodule performance is field emission caused by particulates within the superconducting cavities. To reduce contamination of the inner surfaces during assembly in a cleanroom, the whole string can be connected to a purge system, which maintains a constant overpressure of dry, clean nitrogen gas. Following successes of similar systems at XFEL and Fermilab, Jefferson Lab followed this example for the production of LCLS-II HE cryomodules. Implementing this system required new procedures, infrastructure, and hardware, as well as significant testing of the system before production began. This paper will summarize the implemented controls and procedures, including lessons learned from Fermilab, as well as the results of mock-up tests. Based on the latter, the system was used to assemble the first article string in April 2022, and was also used during a rework required due to issues with cold FPC ceramics two months later. The benefits of using a purge system with regards to procedure, time savings, and added flexibility for potential rework have already proven to provide a significant improvement for the production of LCLS-II-HE cryomodules at Jefferson Lab.

Owen, P. D.↗

Standardized beamline particulate characterization analysis: Initial application to CEBAF and LCLS-II cryomodule components

Despite continuously evolving efforts to minimize and manage the occurrence of particulates in operational SRF accelerator systems, the presence of electron field emission from contaminating particulates on SRF surfaces with high surface electric fields remains a consistent challenge. Jefferson Lab has recently initiated a standardized particulate sampling and characterization practice in order to gain more specific and systematic knowledge of the particulates actually present. It is expected that patterns emerging from such sampling will strengthen source attribution and guide improvement efforts. Initial samples were gathered from a cryomodule and adjoining warm girders that were removed from the CEBAF tunnel for reprocessing. The collection and analysis techniques were also used to characterize particulates on the inside of LCLS-II string components. Samples are transferred to clean industry-standard forensic GSR carbon tape spindles and examined via automated cleanroom SEM scanning for particle localization trends and sizing. The particulates are subsequently analyzed with EDS for elemental composition. A catalogue of found particle types is being accumulated. The methods used and results obtained from these initial applications will be presented.

Reece, Charles↗

Closure Report for Corrective Action Unit 116: Area 25 Test Cell C Facility, Nevada National Security Site, Nevada

This Closure Report (CR) presents information supporting closure of Corrective Action Unit (CAU) 116, Area 25 Test Cell C Facility. This CR complies with the requirements of the Federal Facility Agreement and Consent Order (FFACO) that was agreed to by the State of Nevada; the U.S. Department of Energy (DOE), Environmental Management; the U.S. Department of Defense; and DOE, Legacy Management (FFACO, 1996 [as amended March 2010]). CAU 116 consists of the following two Corrective Action Sites (CASs), located in Area 25 of the Nevada National Security Site: (1) CAS 25-23-20, Nuclear Furnace Piping and (2) CAS 25-41-05, Test Cell C Facility. CAS 25-41-05 consisted of Building 3210 and the attached concrete shield wall. CAS 25-23-20 consisted of the nuclear furnace piping and tanks. Closure activities began in January 2007 and were completed in August 2011. Activities were conducted according to Revision 1 of the Streamlined Approach for Environmental Restoration Plan for CAU 116 (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office [NNSA/NSO], 2008). This CR provides documentation supporting the completed corrective actions and provides data confirming that closure objectives for CAU 116 were met. Site characterization data and process knowledge indicated that surface areas were radiologically contaminated above release limits and that regulated and/or hazardous wastes were present in the facility.

54 ENVIRONMENTAL SCIENCES↗

Solid electrolytes for solid-state and lithium-sulfur batteries

The stringent demands placed on batteries by emerging vehicle technologies such as plug-in and battery electric vehicles suggest that improvements in the safety and performance of electrochemical energy storage devices, as well as concurrent reductions in their cost, are highly desirable. Current strategies for improving performance have largely focused on Li-ion battery chemistries. In this project went beyond the state of the art by pursuing electrolyte chemistries that will enable the use of Li metal anodes and sulfur cathodes, either concurrently in a solid state Li-S battery, or as a means to achieve a Li metal anode which is stable upon cycling. More specifically, our effort advanced strategies to enable Li metal anodes for myriad beyond Li-ion chemistries . LLZO garnet (Li 7 La 3 Zr 2 O 12 ) is the first bulk-scale ceramic electrolyte to exhibit the combination of superionic conductivity (1mS/cm at 298K), high shear modulus (61 GPa) to suppress Li dendrite penetration, and apparent electrochemical stability (0-6V vs Li/Li + ), thus enabling Li metal anodes. However, to date there are no reports confirming LLZO can tolerate current densities > 1mA/cm 2 , thus demonstrating relevance to PHEV/EV batteries. Our goal was to investigate the mechanisms that govern the Li-LLZO interfacial stability as a function of current density. We determined that defects in polycrystalline LLZO reduce the critical current density (CCD). Primarily contaminants on the LLZO surface and grain boundaries were the primary defects the limited the CCD. Using our experience with synthesis and processing (Sakamoto and Wolfenstine) and sophisticated materials characterization (Nanda), we precisely controlled atomistic and microstructural defects and correlated their effects on controlling the critical current density. These data fed into multi-scale computation models (Siegel and Monroe) to isolate and quantify the roles that each defect played in controlling the critical current density. Bridging this knowledge gap allowed us to demonstrate that LLZO can withstand > 1mA/cm 2 .

25 ENERGY STORAGE↗

Preliminary Deposition Modeling: For Determining the Deposition of Corrosive Contaminants on SNF Canisters

This report fulfills the M3 milestone M3SF-20PN010207045. During fiscal year (FY) 2019, Pacific Northwest National Laboratory (PNNL) worked to develop initial deposition and particle tracking models which could be used to better understand how corrosive contaminants deposit on the surfaces of spent nuclear fuel (SNF) canisters during dry storage. These models may be useful in understanding the likelihood of chloride induced stress corrosion cracking (CISCC) on SNF canisters

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Phased Construction Completion Report for Decontamination Laundry Demolition at the Oak Ridge National Laboratory

This Phased Construction Completion Report (PCCR) documents completion of demolition, waste disposition, and slab stabilization activities of Building 2523 (Decontamination Laundry) for the Oak Ridge National Laboratory (ORNL). The Decontamination Laundry is located directly north of the intersection of White Oak Avenue and the 2519 Access Road. This demolition scope included the removal of the above-grade structures and facility components associated with Building 2523. This scope included the removal of Building 2523 (and all remaining contents inside), Trailer 2523A (and all remaining contents inside), an above-grade wastewater tank, and a wooden access porch connecting Buildings 2523 and Trailer 2523A. On the north side of Building 2523, above-grade portions of selected remaining foundations/stairs were removed from former Building 2517 to make room to stage waste containers. Building 2621 is west of the Laundry Building and Buildings 2547 and 2649 are to the east, while Building 2525 is to the north. Building 2523 is located within Bethel Valley Exposure Unit (EU) 3. The total area of the EU is approximately 39 acres. The area within EU 3 is bounded by First Street on the west, Central Avenue on the north, Third Street on the east and south. The slab of Building 2523 has been stabilized with a cap of flowable fill concrete and asphalt to contain residual radiological contamination and to provide surface suitable for vehicle parking. No below-grade demolition actions were performed during this task.

99 GENERAL AND MISCELLANEOUS↗

Closure Report for Corrective Action Unit 116: Area 25 Test Cell C Facility, Nevada National Security Site, Nevada with ROTC-1

CR loaded to this OSTI record. Just adding new file which includes CR plus new ROTC 1 and update the metadata to the following: This Closure Report (CR) presents information supporting closure of Corrective Action Unit (CAU) 116, Area 25 Test Cell C Facility. This CR complies with the requirements of the Federal Facility Agreement and Consent Order (FFACO) that was agreed to by the State of Nevada; the U.S. Department of Energy (DOE), Environmental Management; the U.S. Department of Defense; and DOE, Legacy Management (FFACO, 1996 [as amended March 2010]). CAU 116 consists of the following two Corrective Action Sites (CASs), located in Area 25 of the Nevada National Security Site: (1) CAS 25-23-20, Nuclear Furnace Piping and (2) CAS 25-41-05, Test Cell C Facility. CAS 25-41-05 consisted of Building 3210 and the attached concrete shield wall. CAS 25-23-20 consisted of the nuclear furnace piping and tanks. Closure activities began in January 2007 and were completed in August 2011. Activities were conducted according to Revision 1 of the Streamlined Approach for Environmental Restoration Plan for CAU 116 (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office [NNSA/NSO], 2008). This CR provides documentation supporting the completed corrective actions and provides data confirming that closure objectives for CAU 116 were met. Site characterization data and process knowledge indicated that surface areas were radiologically contaminated above release limits and that regulated and/or hazardous wastes were present in the facility. The Record of Technical Change 1 updated the use restriction information.

54 ENVIRONMENTAL SCIENCES↗

Corrective Action Decision Document for Corrective Action Unit 563: Septic Systems, Nevada Test Site, Nevada, Revision 0

This Corrective Action Decision Document has been prepared for Corrective Action Unit (CAU) 563, Septic Systems, in accordance with the Federal Facility Agreement and Consent Order (FFACO, 1996; as amended January 2007). The corrective action sites (CASs) for CAU 563 are located in Areas 3 and 12 of the Nevada Test Site, Nevada, and are comprised of the following four sites: •03-04-02, Area 3 Subdock Septic Tank •03-59-05, Area 3 Subdock Cesspool •12-59-01, Drilling/Welding Shop Septic Tanks •12-60-01, Drilling/Welding Shop Outfalls The purpose of this Corrective Action Decision Document is to identify and provide the rationale for the recommendation of a corrective action alternative (CAA) for the four CASs within CAU 563. Corrective action investigation (CAI) activities were performed from July 17 through November 19, 2007, as set forth in the CAU 563 Corrective Action Investigation Plan (NNSA/NSO, 2007). Analytes detected during the CAI were evaluated against appropriate final action levels (FALs) to identify the contaminants of concern (COCs) for each CAS. The results of the CAI identified COCs at one of the four CASs in CAU 563 and required the evaluation of CAAs. Assessment of the data generated from investigation activities conducted at CAU 563 revealed the following: •CASs 03-04-02, 03-59-05, and 12-60-01 do not contain contamination at concentrations exceeding the FALs. •CAS 12-59-01 contains arsenic and chromium contamination above FALs in surface and near-surface soils surrounding a stained location within the site. Based on the evaluation of analytical data from the CAI, review of future and current operations at CAS 12-59-01, and the detailed and comparative analysis of the potential CAAs, the following corrective actions are recommended for CAU 563.

Evenson, Grant↗

Insert sleeve prevents tube soldering contamination

Teflon sleeve insert prevents contamination of internal tube surfaces by solder compound during soldering operations that connect and seal the tube ends. The sleeve insert is pressed into the mating tube ends with a slight interference fit.

Stein, J.↗

Organic analyses of selected areas of Surveyor III recovered on the Apollo 12 mission.

Results of organic analyses of certain parts of the Surveyor 3 television camera retrieved from the moon by the Apollo 12 astronauts. Organic contamination of the mirror surface and camera exterior (shroud) is reported and is attributed to spacecraft outgassing, Lunar Module descent engine blasting, possible Surveyor 3 engine exhaust products, and unknown sources.

Simoneit, B. R.↗