Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D PRINTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Thermal Performance of Triply Periodic Minimal Surface Lattice Structures in Single-Phase Dielectric Fluid Cooling of Power Electronics

Additive manufacturing has transformed thermal management by enabling the production of complex, optimized geometries that conventional manufacturing methods cannot achieve. This study investigates the single-phase convective heat transfer performance of gyroid triply periodic minimal surface (TPMS) lattice structures with functional porosity. TPMS structures provide high surface area to volume ratios and are amenable to 3D printing. A gyroid numerical model was created and validated against an existing experimental study with a similar feature size to the investigated geometries. The TPMS structure has a periodic width of 1.6 mm, a length of 10 mm, and a height of 4 mm, with a functional porosity ranging from 0.5 to 0.8, decreasing with distance from the heated surface. Three different flow configurations were examined for an inlet fluid temperature of 70 °C. The inlet velocities range from 0.01 to 1.2 m/s, corresponding to a Reynolds number range of 10–900 with a heat flux of 50 W/cm 2 applied at the base. AmpCool ® AC-110 dielectric fluid (Prandtl number 59.5) was used as the coolant. Thermal performance and friction characteristics were studied for the three flow orientations. The parallel flow configuration was identified as the most efficient for heat removal. A detailed analysis of the numerical results highlights the underlying physics behind the thermal performance differences among the flow configurations.

33 ADVANCED PROPULSION SYSTEMS↗

Torch End-Effector and TIG Electrode Changeout Design for a TIG Welding Robot Used in Metal Big Area Additive Manufacturing

Metal Big Area Additive Manufacturing (mBAAM) is a promising approach to large-scale metal additive manufacturing (AM) or 3D printing. The mBAAM system uses an arc-based wire-fed welding robot to build metal parts. A multi-degree-of-freedom robotic arm is known for its extensive range of motion and reliable tool handling. Attaching a torch end-effector to a robotic arm gives it welding capabilities; however, this decreases the motion range and dynamics of the robot. As a result, build volume and printing accuracy are decreased. Additionally, only a portion of time is spent printing in an arc-based process. Maintenance leads to downtime on the system. In a tungsten inert gas (TIG)-based process, the torch electrode wears out over time and must be changed to avoid defective deposition. This paper proposes an approach for a compact torch end-effector to improve the robot’s build volume. This paper also proposes an approach to reducing non-printing process time by designing and implementing a semi-automated electrode changing system.

Masuo, Chris↗

Accelerating Large-Format Metal Additive Manufacturing: How Controls R&D is Driving Speed, Scale, and Efficiency

This article highlights work at Oak Ridge National Laboratory’s Manufacturing Demonstration Facility to develop closed-loop, feedback control for laser-wire based Directed Energy Deposition, a form of metal Big Area Additive Manufacturing (m-BAAM), a process being developed in partnership with GKN Aerospace specifically for the production of Ti-6Al-4V pre-forms for aerospace components. A large-scale structural demonstrator component is presented as a case-study in which not just control, but the entire 3D printing workflow for m-BAAM is discussed in detail, including design principles for large-format metal AM, toolpath generation, parameter development, process control, and system operation, as well as post-print net-shape geometric analysis and finish machining. In terms of control, a multi-sensor approach has been utilized to measure both layer height and melt pool size, and multiple modes of closed-loop control have been developed to manipulate process parameters (laser power, print speed, deposition rate) to control these variables. Layer height control and melt pool size control have yielded excellent local (intralayer) and global (component-level) geometry control, and the impact of melt pool size control in particular on thermal gradients and material properties is the subject of continuing research. Further, these modes of control have allowed the process to advance to higher deposition rates (exceeding 7.5 lb/hr), larger parts (1-meter scale), shorter build times, and higher overall efficiency. The control modes are examined individually, highlighting their development, demonstration, and lessons learned, and it is shown how they operate concurrently to enable the printing of a large-scale, near net shape Ti-6Al-4V component.

Gibson, Brian↗

Optical information transfer through random unknown diffusers using electronic encoding and diffractive decoding

Free-space optical information transfer through diffusive media is critical in many applications, such as biomedical devices and optical communication, but remains challenging due to random, unknown perturbations in the optical path. We demonstrate an optical diffractive decoder with electronic encoding to accurately transfer the optical information of interest, corresponding to, e.g., any arbitrary input object or message, through unknown random phase diffusers along the optical path. This hybrid electronic-optical model, trained using supervised learning, comprises a convolutional neural network-based electronic encoder and successive passive diffractive layers that are jointly optimized. After their joint training using deep learning, our hybrid model can transfer optical information through unknown phase diffusers, demonstrating generalization to new random diffusers never seen before. The resulting electronic-encoder and optical-decoder model was experimentally validated using a 3D-printed diffractive network that axially spans <70λ, where λ = 0.75 mm is the illumination wavelength in the terahertz spectrum, carrying the desired optical information through random unknown diffusers. The presented framework can be physically scaled to operate at different parts of the electromagnetic spectrum, without retraining its components, and would offer low-power and compact solutions for optical information transfer in free space through unknown random diffusive media.

36 MATERIALS SCIENCE↗

SU-E-T-463: Quantification of Rotational Variation in Mouse Setup for IGRT

Purpose: New small-animal irradiators include extremely precise IGRT capabilities. However, mouse immobilization and localization remains a challenge. In particular, unlike week-to-week translational displacements, rotational changes in positioning are not easily corrected for in subject setup. Using two methods of setup, we aim to quantify week-to-week rotational variation in mice for the purpose of IGRT planning in small animal studies. Methods: Ten mice were imaged weekly using breath-hold CBCT (X-RAD 225 Cx), with the mouse positioned in a half-pipe support, providing 40 scans. A second group of two mice were positioned in a 3D printed immobilization device, which was created using a CT from a similarly shaped mouse, providing 10 scans. For each mouse, the first image was taken to be the reference image. Subsequent CT images were then rigidly registered, based on bony anatomy. Rotations in the axial (roll), sagittal (pitch), and coronal (yaw) planes were recorded and used to quantify variation in angular setup. Results: For the mice imaged in the half pipe, average magnitude of roll was found to be 5.4±4.6° (range: −12.9:18.86°), of pitch 1.6±1.3° (range: −1.4:4.7°), and of yaw 1.9±1.5° (range −5.4:1.1°). For the mice imaged in the printed setup; average magnitude of roll was found to be 0.64±0.6° (range: −2.1:1.0°), of pitch 0.6±0.4° (range: 0.0:1.3°), and of yaw 0.2±0.1° (range: 0.0:0.4°). The printed setup provided reduction in roll, pitch, and yaw by 88, 62, and 90 percent, respectively. Conclusion: For the typical setup routine, roll in mouse position is the dominant source of rotational variation. However, when a printed device was used, drastic improvements in mouse immobilization were seen. This work provides a promising foundation for mouse immobilization, required for full scale small animal IGRT. Currently, we are making improvements to allo±w the use of a similar system for MR, PET, and bioluminescence.

60 APPLIED LIFE SCIENCES↗

Quantum noise properties of CT images with anatomical textured backgrounds across reconstruction algorithms: FBP and SAFIRE

Purpose: Quantum noise properties of CT images are generally assessed using simple geometric phantoms with uniform backgrounds. Such phantoms may be inadequate when assessing nonlinear reconstruction or postprocessing algorithms. The purpose of this study was to design anatomically informed textured phantoms and use the phantoms to assess quantum noise properties across two clinically available reconstruction algorithms, filtered back projection (FBP) and sinogram affirmed iterative reconstruction (SAFIRE). Methods: Two phantoms were designed to represent lung and soft-tissue textures. The lung phantom included intricate vessel-like structures along with embedded nodules (spherical, lobulated, and spiculated). The soft tissue phantom was designed based on a three-dimensional clustered lumpy background with included low-contrast lesions (spherical and anthropomorphic). The phantoms were built using rapid prototyping (3D printing) technology and, along with a uniform phantom of similar size, were imaged on a Siemens SOMATOM Definition Flash CT scanner and reconstructed with FBP and SAFIRE. Fifty repeated acquisitions were acquired for each background type and noise was assessed by estimating pixel-value statistics, such as standard deviation (i.e., noise magnitude), autocorrelation, and noise power spectrum. Noise stationarity was also assessed by examining the spatial distribution of noise magnitude. The noise properties were compared across background types and between the two reconstruction algorithms. Results: In FBP and SAFIRE images, noise was globally nonstationary for all phantoms. In FBP images of all phantoms, and in SAFIRE images of the uniform phantom, noise appeared to be locally stationary (within a reasonably small region of interest). Noise was locally nonstationary in SAFIRE images of the textured phantoms with edge pixels showing higher noise magnitude compared to pixels in more homogenous regions. For pixels in uniform regions, noise magnitude was reduced by an average of 60% in SAFIRE images compared to FBP. However, for edge pixels, noise magnitude ranged from 20% higher to 40% lower in SAFIRE images compared to FBP. SAFIRE images of the lung phantom exhibited distinct regions with varying noise texture (i.e., noise autocorrelation/power spectra). Conclusions: Quantum noise properties observed in uniform phantoms may not be representative of those in actual patients for nonlinear reconstruction algorithms. Anatomical texture should be considered when evaluating the performance of CT systems that use such nonlinear algorithms.

60 APPLIED LIFE SCIENCES↗

Development of realistic physical breast phantoms matched to virtual breast phantoms based on human subject data

Purpose: Physical phantoms are essential for the development, optimization, and evaluation of x-ray breast imaging systems. Recognizing the major effect of anatomy on image quality and clinical performance, such phantoms should ideally reflect the three-dimensional structure of the human breast. Currently, there is no commercially available three-dimensional physical breast phantom that is anthropomorphic. The authors present the development of a new suite of physical breast phantoms based on human data. Methods: The phantoms were designed to match the extended cardiac-torso virtual breast phantoms that were based on dedicated breast computed tomography images of human subjects. The phantoms were fabricated by high-resolution multimaterial additive manufacturing (3D printing) technology. The glandular equivalency of the photopolymer materials was measured relative to breast tissue-equivalent plastic materials. Based on the current state-of-the-art in the technology and available materials, two variations were fabricated. The first was a dual-material phantom, the Doublet. Fibroglandular tissue and skin were represented by the most radiographically dense material available; adipose tissue was represented by the least radiographically dense material. The second variation, the Singlet, was fabricated with a single material to represent fibroglandular tissue and skin. It was subsequently filled with adipose-equivalent materials including oil, beeswax, and permanent urethane-based polymer. Simulated microcalcification clusters were further included in the phantoms via crushed eggshells. The phantoms were imaged and characterized visually and quantitatively. Results: The mammographic projections and tomosynthesis reconstructed images of the fabricated phantoms yielded realistic breast background. The mammograms of the phantoms demonstrated close correlation with simulated mammographic projection images of the corresponding virtual phantoms. Furthermore, power-law descriptions of the phantom images were in general agreement with real human images. The Singlet approach offered more realistic contrast as compared to the Doublet approach, but at the expense of air bubbles and air pockets that formed during the filling process. Conclusions: The presented physical breast phantoms and their matching virtual breast phantoms offer realistic breast anatomy, patient variability, and ease of use, making them a potential candidate for performing both system quality control testing and virtual clinical trials.

60 APPLIED LIFE SCIENCES↗

SU-E-J-58: Comparison of Conformal Tracking Methods Using Initial, Adaptive and Preceding Image Frames for Image Registration

Purpose: Accounting for tumor motion during radiation therapy is important to ensure that the tumor receives the prescribed dose. Increasing the field size to account for this motion exposes the surrounding healthy tissues to unnecessary radiation. In contrast to using motion-encompassing techniques to treat moving tumors, conformal radiation therapy (RT) uses a smaller field to track the tumor and adapts the beam aperture according to the motion detected. This work investigates and compares the performance of three markerless, EPID based, optical flow methods to track tumor motion with conformal RT. Methods: Three techniques were used to track the motions of a 3D printed lung tumor programmed to move according to the tumor of seven lung cancer patients. These techniques utilized a multi-resolution optical flow algorithm as the core computation for image registration. The first method (DIR) registers the incoming images with an initial reference frame, while the second method (RFSF) uses an adaptive reference frame and the third method (CU) uses preceding image frames for registration. The patient traces and errors were evaluated for the seven patients. Results: The average position errors for all patient traces were 0.12 ± 0.33 mm, −0.05 ± 0.04 mm and −0.28 ± 0.44 mm for CU, DIR and RFSF method respectively. The position errors distributed within 1 standard deviation are 0.74 mm, 0.37 mm and 0.96 mm respectively. The CU and RFSF algorithms are sensitive to the characteristics of the patient trace and produce a wider distribution of errors amongst patients. Although the mean error for the DIR method is negatively biased (−0.05 mm) for all patients, it has the narrowest distribution of position error, which can be corrected using an offset calibration. Conclusion: Three techniques of image registration and position update were studied. Using direct comparison with an initial frame yields the best performance. The authors would like to thank Dr.YeLin Suh for making the Cyberknife dataset available to us. Scholarship funding from the Natural Sciences and Engineering Research Council of Canada (NSERC) and CancerCare Manitoba Foundation is acknowledged.

60 APPLIED LIFE SCIENCES↗

SU-E-T-124: Anthropomorphic Phantoms for Confirmation of Linear Accelerator Based Small Animal Irradiation

Purpose: To document the support of radiobiological small animal research by a modern radiation oncology facility. This study confirms that a standard, human use linear accelerator can cover the range of experiments called for by researchers performing animal irradiation. A number of representative, anthropomorphic murine phantoms were made. The phantoms confirmed the small field photon and electron beams dosimetry validated the use of the linear accelerator for rodents. Methods: Laser scanning a model, CAD design and 3D printing produced the phantoms. The phantoms were weighed and CT scanned to judge their compatibility to real animals. Phantoms were produced to specifically mimic lung, gut, brain, and othotopic lesion irradiations. Each phantom was irradiated with the same protocol as prescribed to the live animals. Delivered dose was measured with small field ion chambers, MOS/FETs or TLDs. Results: The density of the phantom material compared to density range across the real mice showed that the printed material would yield sufficiently accurate measurements when irradiated. The whole body, lung and gut irradiations were measured within 2% of prescribed doses with A1SL ion chamber. MOSFET measurements of electron irradiations for the orthotopic lesions allowed refinement of the measured small field output factor to better than 2% and validated the immunology experiment of irradiating one lesion and sparing another. Conclusion: Linacs are still useful tools in small animal bio-radiation research. This work demonstrated a strong role for the clinical accelerator in small animal research, facilitating standard whole body dosing as well as conformal treatments down to 1cm field. The accuracy of measured dose, was always within 5%. The electron irradiations of the phantom brain and flank tumors needed adjustment; the anthropomorphic phantoms allowed refinement of the initial output factor measurements for these fields which were made in a large block of solid water.

60 APPLIED LIFE SCIENCES↗

SU-E-T-652: Quantification of Dosimetric Uncertainty of I-125 COMS Eye Plaque

Purpose: To compare dosimetrically three plan calculation systems (Plato, Varian Brachytherapy, and in-house-made Excel) available for I-125 COMS eye plaque treatment with measurement. Methods: All systems assume homogeneous media and calculations are based on a three-dimensional Cartesian coordinates, Plato and Brachytherapy Planning are based on AAPM TG-43 and the in-house Excel program only on inverse square corrections. Doses at specific depths were measured with EBT3 Gafchromic film from a fully loaded and a partially loaded 16 mm plaque (13 and 8 seeds respectively, I-125, model 6711 GE, Oncura). Measurements took place in a water tank, utilizing solid water blocks and a 3D-printed plaque holder. Taking advantage that gafchromic film has low energy dependence, a dose step wedge was delivered with 6 MV photon beam from a Varian 2100 EX linac for calibration. The gray-scale to dose in cGy was obtained with an Epson Expression 10000 XL scanner in the green channel. Treatment plans were generated for doses of 2200 cGy to a depth of 7 mm, and measurements were taken on a sagittal plane. Results: The calculated dose at the prescription point was 2242, 2344, and 2211 cGy with Excel, Brachyvision and Plato respectively for a fully loaded plaque, for the partially loaded plaque the doses were 2266, 2477, and 2193 cGy respectively. At 5 mm depth the doses for Brachyvision and Plato were comparable (3399 and 3267 cGy respectively), however, the measured dose in film was 3180 cGy which was lower by as much as 6.4% in the fully loaded plaque and 7.6% in the partially loaded plaque. Conclusion: Careful methodology and calibration are essential when measuring doses at specific depth due to the sensitivity and rapid dose fall off of I-125.

61 RADIATION PROTECTION AND DOSIMETRY↗

TU-AB-201-10: Novel Conformal Skin Brachytherapy Device

Purpose: A novel conformal skin brachytherapy (CSBT) device was developed to provide patient specific treatment for small inoperable lesions and irregular surfaces that are not good candidates for electron external beam, e.g. eyelids, nose, lips, ears, etc. Methods: A prototype was built and tested using radioactive seeds spaced by 1.5 mm attached to a 3D printed template. Seeds were allowed to move independently at treatment surface to conform to target geometry. Beta-emitter Praseodymium-142 (half-life: 19.12 h, average beta energy: 809 keV) and Iodine-125 Model 6711 (half-life: 59.4 days, average gamma energy: 28 keV) seeds were used to test the feasibility of the device in solid water phantom for different prescription depths and surface areas. Percent depth doses and dose profiles were analyzed. MCNPX2.6 Monte Carlo Simulation and Gafchromic EBT3 film measurements were performed for a single Pr-142 seed. Treatment with nineteen I-125 seeds was planned in BrachyVision and measured experimentally for a total dose of 500 cGy at 5.0 mm depth. Results: For a single Pr-142 seed, dose was 500.0 cGy at surface and 17.4 cGy at 5.00 mm. BrachyVision planned and film doses for I-125 seed matrix were 500 cGy and 473.5 cGy at 5 mm depth and 171.0 cGy and 201.0 cGy at 10 mm depth. Total covered surface area for Pr-142 and I-125 were 2.35 mm{sup 2} and 88.24 mm{sup 2} respectively. Profile dose fall-off showed to be very conformal to contact area with 50% of the total surface dose from a single Pr-142 and array of I-125 seeds being deposited at 0.72 mm and 0.65 mm respectively from the central axis. Conclusion: CSBT device provides a high conformal dose to small surfaces. BrachyVision can be used to predict clinical dose distributions for multiple seeds matrix. Different radioactive seeds can be used to suit prescription depth and treatment area.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRB-02: Development of a Micro-Sized Dosimeter for Real-Time Dose Monitoring and Small Field Dosimetry

Purpose: To investigate a miniature optical dosimeter for real-time, high-resolution dosimetry, and explore its potential applications for in vivo measurements and small field dosimetry. Methods: A micro-sized hemispherical (400 µm radius) scintillating detector was constructed from lanthanide activated phosphors doped with Europium (GOS:Eu) and encapsulated in a 17 gauge plastic catheter. A photon counting PMT and CCD-chip spectrometer were used to detect signals emitted from the detector. A single band-passing spectral approach (630nm) was implemented to discriminate the micro-phosphor optical signal from background signals (Cerenkov radiation) in the optical fiber. To test real-time monitoring capabilities, a 3D-printed phantom was used to detect an 192Ir HDR brachytherapy source at locations ranging from 1 to 4 cm radially and 12 cm along the travel axis of the HDR wire. To test the application of the micro-sized detector for small field dosimetry, the linearity of detector was characterized through irradiation of 6MV photon beam at dose-rates ranging from 100 to 600 MU, and the effect of field size was characterized through detections of beams ranging from 30×30 to 1×1 cm2 size. Results: With a 1 second integration time for the spectrometer, the recorded measurements indicated that the micro-sized detector allowed accurate detection of source position at distances of up to 6 cm along the axis of travel in water. EB measurements showed that the detected signal was linearly correlated with dose rate (R{sup 2} = 0.99). The crossbeam profile was determined with a step size of ∼500 µm. Conclusion: Miniaturization of optical dosimeters is shown to be possible through the construction of lanthanide activated doped phosphors detectors. The small size of the detector makes it amenable to a variety of applications, including real-time dose delivery verification during HDR brachytherapy and EB beam calibrations in small fields.

60 APPLIED LIFE SCIENCES↗

WE-EF-210-07: Development of a Minimally Invasive Photo Acoustic Imaging System for Early Prostate Cancer Detection

Purpose: The objective of this work is to design, implement and characterize a catheter-based ultrasound/photoacoustic imaging probe for early-diagnosis of prostate cancer and to aid in image-guided radiation therapy. Methods: The need to image across 6–10cm of tissue to image the whole prostate gland limits the resolution achievable with a transrectal ultrasound approach. In contrast, the urethra bisects the prostate gland, providing a minimally invasive pathway for deploying a high resolution ultrasound transducer. Utilizing a high-frequency (20MHz) ultrasound/photoacoustic probe, high-resolution structural and molecular imaging of the prostate tissue is possible. A custom 3D printed probe containing a high-frequency single-element ultrasound transducer is utilized. The diameter of the probe is designed to fit inside a Foley catheter and the probe is rotated around the central axis to achieve a circular B-scan. A custom ultrasound amplifier and receiver was set up to trigger the ultrasound pulse transmission and record the reflected signal. The reconstructed images were compared to images generated by traditional 5 MHz ultrasound transducers. Results: The preliminary results using the high-frequency ultrasound probe show that it is possible to resolve finely detailed information in a prostate tissue phantom that was not achievable with previous low-frequency ultrasound systems. Preliminary ultrasound imaging was performed on tissue mimicking phantom and sensitivity and signal-to-noise ratio of the catheter was measured. Conclusion: In order to achieve non-invasive, high-resolution, structural and molecular imaging for early-diagnosis and image-guided radiation therapy of the prostate tissue, a transurethral catheter was designed. Structural/molecular imaging using ultrasound/photoacoustic of the prostate tissue will allow for localization of hyper vascularized areas for early-stage prostate cancer diagnosis.

60 APPLIED LIFE SCIENCES↗

SU-G-201-03: Automation of High Dose Rate Brachytherapy Quality Assurance: Development of a Radioluminescent Detection System for Simultaneous Detection of Activity, Timing, and Positioning

Purpose: Accuracy of positioning, timing and activity is of critical importance for High Dose Rate (HDR) brachytherapy delivery. Respective measurements via film autoradiography, stop-watches and well chambers can be cumbersome, crude or lack dynamic source evaluation capabilities. To address such limitations, a single device radioluminescent detection system enabling automated real-time quantification of activity, position and timing accuracy is presented and experimentally evaluated. Methods: A radioluminescent sheet was fabricated by mixing Gd?O?S:Tb with PDMS and incorporated into a 3D printed device where it was fixated below a CMOS digital camera. An Ir-192 HDR source (VS2000, VariSource iX) with an effective active length of 5 mm was introduced using a 17-gauge stainless steel needle below the sheet. Pixel intensity values for determining activity were taken from an ROI centered on the source location. A calibration curve relating intensity values to activity was generated and used to evaluate automated activity determination with data gathered over 6 weeks. Positioning measurements were performed by integrating images for an entire delivery and fitting peaks to the resulting profile. Timing measurements were performed by evaluating source location and timestamps from individual images. Results: Average predicted activity error over 6 weeks was .35 ± .5%. The distance between four dwell positions was determined by the automated system to be 1.99 ± .02 cm. The result from autoradiography was 2.00 ± .03 cm. The system achieved a time resolution of 10 msec and determined the dwell time to be 1.01 sec ± .02 sec. Conclusion: The system was able to successfully perform automated detection of activity, positioning and timing concurrently under a single setup. Relative to radiochromic and radiographic film-based autoradiography, which can only provide a static evaluation positioning, optical detection of temporary radiation induced luminescence enables dynamic detection of position enabling automated quantification of timing with millisecond accuracy.

60 APPLIED LIFE SCIENCES↗

MO-FG-BRA-05: Dosimetric and Radiobiological Validation of Respiratory Gating in Conventional and Hypofractionated Radiotherapy of the Lung: Effect of Dose, Dose Rate, Gating Window and Breathing Pattern

Purpose: to evaluate the dosimetric and radiobiological consequences from having different gating windows, dose rates, and breathing patterns in gated VMAT lung radiotherapy. Methods: A novel 3D-printed moving phantom with central high and peripheral low tracer uptake regions was 4D FDG-PET/CT-scanned using ideal, patient-specific regular, and irregular breathing patterns. A scan of the stationary phantom was obtained as a reference. Target volumes corresponding to different uptake regions were delineated. Simultaneous integrated boost (SIB) 6 MV VMAT plans were produced for conventional and hypofractionated radiotherapy, using 30–70 and 100% cycle gating scenarios. Prescribed doses were 200 cGy with SIB to 240 cGy to high uptake volume for conventional, and 800 with SIB to 900 cGy for hypofractionated plans. Dose rates of 600 MU/min (conventional and hypofractionated) and flattening filter free 1400 MU/min (hypofractionated) were used. Ion chamber measurements were performed to verify delivered doses. Vials with A549 cells placed in locations matching ion chamber measurements were irradiated using the same plans to measure clonogenic survival. Differences in survival for the different doses, dose rates, gating windows, and breathing patterns were analyzed. Results: Ion chamber measurements agreed within 3% of the planned dose, for all locations, breathing patterns and gating windows. Cell survival depended on dose alone, and not on gating window, breathing pattern, MU rate, or delivery time. The surviving fraction varied from approximately 40% at 2Gy to 1% for 9 Gy and was within statistical uncertainty relative to that observed for the stationary phantom. Conclusions: Use of gated VMAT in PET-driven SIB radiotherapy was validated using ion chamber measurements and cell survival assays for conventional and hypofractionated radiotherapy.

60 APPLIED LIFE SCIENCES↗

TU-C-HORIZONS-01: The Expanding Horizons Travel Grant Program: ePosters and Discussion

The Expanding Horizons travel grant program provides opportunity for students and trainees to broaden the scope of scientific meetings they attend and gain insight from research outside traditional domains of medical physics. Through participation in such conferences, early-career researchers are introduced to new topics with relevance to medical physics research as a means to expand the scientific horizons of our discipline. This year, 21 Expanding Horizons travel grants were awarded, granting travel to 17 conferences, including: Radiomics, the World Molecular Imaging Society (WMIS), the 3D Printing Conference and Expo, the GPU Technology Conference, the SIAM Imaging Science Conference, the Human Brain Mapping Conference, the OSA Conference on Clinical and Translational Biophotonics, the Society for Neuroscience, the AACR Conference on Tumor Microenvironment, and the Conference on Knowledge Discovery and Data Mining. The Expanding Horizons electronic poster session gives a venue for AAPM conference attendees to meet and discuss with awardees, learn the hot topics and emerging research areas presented at these conferences, and understand the relevance to future medical physics research.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-DE-BRA-04: A Cost-Effective Pixelated EPID Scintillator for Enhanced Contrast and DQE

Purpose: Beams-eye-view imaging applications such as real-time soft-tissue motion estimation and MV-CBCT are hindered by the inherently low image contrast of electronic portal imaging devices (EPID) currently in clinical use. We investigate a cost effective scintillating glass that provides substantially increased detective quantum efficiency (DQE) and contrast to noise ratio (CNR). Methods: A pixelated scintillator prototype was built from LKH-5 glass. The array is 12mm thick; 42.4×42.4cm2 wide and features 1.51mm pixel pitch with 20µm separation (glue+septa). The LKH-5 array was mounted on the active matrix flat panel imager (AMPFI) of an AS-1200 (Varian) with the GdO2S2:Tb removed. A second AS-1200 was utilized as reference detector. The prototype EPID was characterized in terms of CNR, modulation transfer function (MTF) and DQE. Additionally, the visibility of various fiducial markers typically used in the clinic as well as a realistic 3D-printed lung tumor model was assessed. All items were placed in a 12cm thick solid water phantom. CNR is estimated using a Las Vegas contrast phantom, presampled MTF is estimated using a slanted slit technique and the DQE is calculated from measured normalized noise power spectra (NPS) and the MTF. Results: DQE(0) for the LKH-5 prototype increased by a factor of 8× to about 10%, compared to the AS-1200 equipped with its standard GdO2S2:Tb scintillator. CNR increased by a factor of 5.3×. Due to the pixel size the MTF50 decreased by about 55% to 0.23lp/mm. The visibility of all fiducial markers as well as the tumor model were however markedly improved in comparison to an acquisition with the same parameters using the GdO2S2:Tb scintillator. Conclusion: LKH-5 scintillating glasses allow the cost effective construction of thick pixelated scintillators for portal imaging which can yield a substantial increase in DQE and CNR. Soft tissue and fiducial marker visibility was found to be markedly improved. The project was supported in part by NIH grant R01CA188446-01 and a grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗