Search NASA⌕ Search

SEARCH · Search NASA

Results for “ADOPTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Effects of management and pore characteristics on organic matter composition of macroaggregates: evidence from characterization of organic matter and imaging

Macroaggregates are of interest because of their fast response to land management and their role in the loss or restoration of soil organic carbon (SOC). The study included two experiments. In Experiment I, we investigated the effect of long-term (27 years) land management on the chemical composition of organic matter (OM) of macroaggregates. Macroaggregates were sampled from topsoil under conventional cropping, cover cropping and natural succession systems. The OM of macroaggregates from conventional cropping was more decomposed than that of cover cropping and especially natural succession, based on larger δ 15 N values and decomposition indices determined by multiple magic-angle spinning nuclear magnetic resonance ( 13 C CP/MAS NMR) and Fourier transform infrared (FTIR) spectroscopy. Previous research at the sites studied suggested that this was mainly because of reduced diversity and activity of the decomposer community, change in nutrient stoichiometry from fertilization and contrasting formation pathways of macroaggregates in conventional cropping compared with cover cropping and, specifically, natural succession. In Experiment II, we investigated the relation between OM composition and pore characteristics of macroaggregates. Macroaggregates from the natural succession system only were studied. We determined 3-D pore-size distribution of macroaggregates with X-ray microtomography, for which we cut the macroaggregates into sections that had contrasting dominant pore sizes. Then, we characterized the OM of macroaggregate sections with FTIR and δ 15 N methods. The results showed that within a macroaggregate, the OM was less decomposed in areas where the small (13–32 µm) or large (136–260 µm) pores were abundant. This was attributed to the role of large pores in supplying fresh OM and small pores in the effective protection of OM in macroaggregates. Finally, previous research at the site studied had shown increased abundance of large and small intra-aggregate pores following adoption of less intensive management systems. It appears that land management can alter the OM composition of macroaggregates, partly by the regulation of OM turnover at the intra-aggregate scale.

54 ENVIRONMENTAL SCIENCES↗

Response of precipitation extremes to idealized global warming in an aqua-planet climate model: towards a robust projection across different horizontal resolutions

Current climate models produce quite heterogeneous projections for the responses of precipitation extremes to future climate change. To help understand the range of projections from multimodel ensembles, a series of idealized 'aquaplanet' Atmospheric General Circulation Model (AGCM) runs have been performed with the Community Atmosphere Model CAM3. These runs have been analysed to identify the effects of horizontal resolution on precipitation extreme projections under two simple global warming scenarios. We adopt the aquaplanet framework for our simulations to remove any sensitivity to the spatial resolution of external inputs and to focus on the roles of model physics and dynamics. Results show that a uniform increase of sea surface temperature (SST) and an increase of low-to-high latitude SST gradient both lead to increase of precipitation and precipitation extremes for most latitudes. The perturbed SSTs generally have stronger impacts on precipitation extremes than on mean precipitation. Horizontal model resolution strongly affects the global warming signals in the extreme precipitation in tropical and subtropical regions but not in high latitude regions. This study illustrates that the effects of horizontal resolution have to be taken into account to develop more robust projections of precipitation extremes.

54 ENVIRONMENTAL SCIENCES↗

Compositional control of radionuclide retention in hollandite-based ceramic waste forms for Cs-immobilization

Hollandite materials, as a class of crystalline nuclear waste forms, are promising candidates for the immobilization of radioactive elements, such as Cs, Ba, as well as a variety of lanthanide and transition-metal fission products. In this study, three Ga-doped titanate hollandite-type phases, Ba 1.33 Ga 2.67 Ti 5.33 O 16 , Ba 0.667 Cs 0.667 Ga 2 Ti 6 O 16 , and Cs 1.33 Ga 1.33 Ti 6.67 O 16 , were synthesized using a solid-state reaction route. All synthesized phases adopted a single phase tetragonal structure, as determined by powder X-ray diffraction (XRD), and elemental analysis confirmed the measured stoichiometries were close to targeted compositions. Extended X-ray absorption fine structure spectroscopy (EXAFS) was used to determine the local structural features for the framework of octahedrally coordinated cations. EXAFS data indicated that Cs 1.33 Ga 1.33 Ti 6.67 O 16 possessed the most disordered local structure centered around the Ga dopant. The enthalpies of formation of all three hollandite phases measured using high-temperature oxide melt solution calorimetry were found to be negative, indicating enthalpies of formation of these hollandites from oxides are thermodynamically stable with respect to their constituent oxides. Furthermore, the formation enthalpies were more negative and hence more favorable with increased Cs content. Finally, aqueous leaching tests revealed that high Cs content hollandite phases exhibited greater Cs retention as compared to low Cs content hollandite. While preliminary in nature, this work draws attention to the links between the capacity for radionuclide retention, atomistic level structural features and bulk thermodynamic properties of materials.

nuclear (including radiation effects), materials a↗

Unveiling and Mapping Polymorphs in Fluorite Y2TiO5 Using 4D-STEM and Unsupervised Machine Learning

Y2TiO5 belongs to the Ln2TiO5 (Ln = lanthanide or Y) family of ceramic materials and exhibits a range of desirable material properties such as radiation tolerance, frustrated magnetism, and large dielectric constant. However, understanding the complex crystal structure of Y2TiO5 remains elusive, given that Y2TiO5 can adopt multiple polymorphs such as cubic, orthorhombic, and hexagonal phases within the lattice. In this work, we report a detailed structural analysis of Y2TiO5 using four-dimensional scanning transmission electron microscopy coupled with unsupervised machine learning. The pyrochlore nanodomains, characterized by the ordered arrangement of yttrium cations on the A site of their A2BO5 structure, are present within the matrix of a predominantly fluorite-structured Y2TiO5 along with a third polymorph, the hexagonal phase. The pyrochlore phase is found to form 2 nm boundary regions around hexagonal phase stacking faults, highlighting the potential influence of the hexagonal phase on the occurrence and distribution of the pyrochlore phase. Lastly, we identify a unique pyrochlore phase with asymmetric arrangement of cation ordering along a single planar direction. Our findings provide invaluable insights into the possible mechanisms stabilizing pyrochlore nanodomains within the fluorite lattice of Y2TiO5.

36 MATERIALS SCIENCE↗

The Vertebrate Breed Ontology: Toward Effective Breed Data Standardization

Abstract Background Limited universally-adopted data standards in veterinary medicine hinder data interoperability and therefore integration and comparison; this ultimately impedes the application of existing information-based tools to support advancement in diagnostics, treatments, and precision medicine. Hypothesis/Objectives A single, coherent, logic-based standard for documenting breed names in health, production, and research-related records will improve data use capabilities in veterinary and comparative medicine. Animals No live animals were used. Methods The Vertebrate Breed Ontology (VBO) was created from breed names and related information compiled from the Food and Agriculture Organization of the United Nations, breed registries, communities, and experts, using manual and computational approaches. Each breed is represented by a VBO term that includes breed information and provenance as metadata. VBO terms are classified using description logic to allow computational applications and Artificial Intelligence–readiness. Results VBO is an open, community-driven ontology representing over 19 500 livestock and companion animal breed concepts covering 49 species. Breeds are classified based on community and expert conventions (e.g., cattle breed) and supported by relations to the breed's genus and species indicated by National Center for Biotechnology Information (NCBI) Taxonomy terms. Relationships between VBO terms (e.g., relating breeds to their foundation stock) provide additional context to support advanced data analytics. VBO term metadata includes synonyms, breed identifiers/codes, and attributed cross-references to other databases. Conclusion and Clinical Importance The adoption of VBO as a standard for breed names in databases and veterinary electronic health records enhances veterinary data interoperability and computability, supporting precision medicine.

Veterinary Sciences↗

Robust biological nitrogen fixation in a model grass–bacterial association

Summary Nitrogen‐fixing rhizobacteria can promote plant growth; however, it is controversial whether biological nitrogen fixation ( BNF ) from associative interaction contributes to growth promotion. The roots of Setaria viridis , a model C 4 grass, were effectively colonized by bacterial inoculants resulting in a significant enhancement of growth. Nitrogen‐13 tracer studies provided direct evidence for tracer uptake by the host plant and incorporation into protein. Indeed, plants showed robust growth under nitrogen‐limiting conditions when inoculated with an ammonium‐excreting strain of Azospirillum brasilense . 11 C‐labeling experiments showed that patterns in central carbon metabolism and resource allocation exhibited by nitrogen‐starved plants were largely reversed by bacterial inoculation, such that they resembled plants grown under nitrogen‐sufficient conditions. Adoption of S. viridis as a model should promote research into the mechanisms of associative nitrogen fixation with the ultimate goal of greater adoption of BNF for sustainable crop production.

Pankievicz, Vânia C. S.↗

System-Level Thermal Management and Reliability of Automotive Electronics: Goals and Opportunities Using Phase-Change Materials

Abstract Electronic packaging for automotive applications are at particular risk of thermomechanical failure due to the naturally harsh conditions it is exposed to. With the rise of electric and hybrid electric vehicles (EVs and HEVs), combined with a desire to miniaturize, the challenge of removing enough heat from electronic devices in automotive vehicles is evolving. This paper closely examines the new challenges in thermal management in various driving environments and aims to classify each existing cooling method in terms of performance. Particular focus is placed upon emerging solutions regarded to hold great potential, such as phase-change materials (PCMs). PCMs have been regarded for some time as a means of transferring heat quickly away from the region with the electronic components and are widely regarded as a possible means of carrying out cooling in large scale from small areas, because of their high latent heat of fusion, high specific heat, temperature stability, and small volume change during phase change, etc. They have already been utilized as a method of passive cooling in electronics in various ways, but their adoption in automotive power electronics, such as in traction inverters, has yet to be fulfilled. A brief discussion is made on some of the potential areas of application and challenges relating to more widespread adoption of PCMs, with reference to a case study using computational model of a commercially available power module used in automotive applications.

Engineering↗

A Novel Approach for Bounding the Stress Experienced by the Core of Utility-Scale Printed Circuit Heat Exchangers Under Thermohydraulic Loads

Printed circuit heat exchangers (PCHEs) have rapidly gained popularity since being introduced nearly three decades ago, and they are currently widely deployed in the petrochemical and aviation industry. Their compactness, thermohydraulic efficiency, inherent suitability for high temperature/pressure fluids containment, and demonstrated durability are some of the reasons the nuclear industry is seeking to adopt this technology as well. However, the relatively strict nuclear-related regulatory design code, especially when classified as critical to the safety of the reactors, is posing challenges to adopting the technology. From stress analysis point of view, one undesirable feature of PCHEs is their geometrical complexity, which is implied by their multilength-scale features. As a result, a full-scale model of a utility-scale exchanger cannot simply be solved on a computer because meshing such components results in a vast number of degrees-of-freedom. Here, this work seeks to address the challenge of stress analyses to PCHEs by presenting a method to simplify the geometry of PCHE designs. The models proposed by this work can be practically analyzed on a standard computer and provide a path for implementing ASME design rules. The analyses presented herein are divided into five separate investigations. Each is carried out to incrementally simplify the analyzed model by addressing features such as the shapes of the flow passages, the complex distribution of stress in large components, the three-dimensionality of the stress and strain, the thermal stresses caused by thermohydraulic operation observed experimentally and more.

42 ENGINEERING↗

Investigating the Combustion Performance of Dual Fuel Combustion with Diesel and Port Injected Hydrogen in a Large Bore Locomotive Engine

The heavy-duty transportation sector has primarily relied on conventional diesel combustion engines given their reliability and high thermal efficiency relative to spark ignition engines, but increased focus on reducing greenhouse gas emissions has led to investigation into alternative fuels. Gaseous hydrogen fuel has garnered a great deal of recent interest in the engine community given it has zero carbon, but hydrogen is not available at the scale and cost that petroleum fuels are currently available, and this is a barrier to adoption for industries that are looking to decarbonize their operations. Because of the fuel flexibility provided, dual fuel technology offers a pathway for some industries to adopt hydrogen as a fuel source while maintaining sufficient flexibility in times and locations where the new fuel is not yet available. This computational study investigates dual fuel combustion in a large bore locomotive engine architecture using direct injected diesel and port injected gaseous hydrogen fuel. With an optimal port fuel injection configuration from previous work, simulations of varying substitution ratio, compression ratio, manifold air temperature, diesel injection timing, and diesel injection pressure were performed to understand their effect on combustion performance. Results indicated that both increased substitution ratio and higher intake air temperature accelerates hydrogen flame propagation and can result in high peak cylinder pressures. Additionally, diesel injection timing and injection pressure were demonstrated as effective methods for controlling dual fuel combustion heat release rates.

ODonnell, Patrick Christopher↗

Readout optimization of multi-amplifier sensing charge-coupled devices for single-quantum measurement

The non-destructive readout capability of the Skipper Charge Coupled Device (CCD) has been demonstrated to reduce the noise limitation of conventional silicon devices to levels that allow single-photon or single-electron counting. The noise reduction is achieved by taking multiple measurements of the charge in each pixel. These multiple measurements come at the cost of extra readout time, which has been a limitation for the broader adoption of this technology in particle physics, quantum imaging, and astronomy applications. This work presents recent results of a novel sensor architecture that uses multiple non-destructive floating-gate amplifiers in series to achieve sub-electron readout noise in a thick, fully-depleted silicon detector to overcome the readout time overhead of the Skipper-CCD. This sensor is called the Multiple-Amplifier Sensing Charge-Coupled Device (MAS-CCD) can perform multiple independent charge measurements with each amplifier, and the measurements from multiple amplifiers can be combined to further reduce the readout noise. We will show results obtained for sensors with 8 and 16 amplifiers per readout stage in new readout operations modes to optimize its readout speed. The noise reduction capability of the new techniques will be demonstrated in terms of its ability to reduce the noise by combining the information from the different amplifiers, and to resolve signals in the order of a single photon per pixel. The first readout operation explored here avoids the extra readout time needed in the MAS-CCD to read a line of the sensor associated with the extra extent of the serial register. The second technique explore the capability of the MAS-CCD device to perform a region of interest readout increasing the number of multiple samples per amplifier in a targeted region of the active area of the device.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration of the Gamma Knife Perfexion using TG-21 and the solid water Leksell dosimetry phantom

Purpose: To calibrate a Gamma Knife (GK) Perfexion using TG-21 with updated chamber-dependent values for modern microionization chambers in the new solid water Leksell dosimetry phantom. This work illustrates a calibration method using commercially available equipment, instruments, and an established dosimetry protocol that may be adopted at any GK center, thus reducing the interinstitutional variation in GK calibration. The calibration was verified by three third-party dosimetry checks. In addition, measurements of the relative output factors are presented and compared to available data and the new manufacturer-provided relative output factors yet to be released. Methods: An absolute dose calibration based on the TG-21 formalism, utilizing recently reported phantom material and chamber-dependent factors, was performed using a microionization chamber in a spherical solid water phantom. The result was compared to other calibration protocols based on TG-51. Independent verification of the machine output was conducted through M.D. Anderson Dosimetry Services (MDADS), using thermoluminescent dosimeters (TLDs) in an anthropomorphic head phantom; the Radiological Physics Center (RPC), using TLDs in the standard Elekta ABS plastic calibration phantom (gray phantom), included with the GK; and through a collaborative international calibration survey by the University of Pittsburgh Medical Center (UPMC) using alanine dosimeters, also in the gray phantom. The alanine dosimeters were read by the National Institute of Standards and Technology. Finally, Gafchromic EBT film was used to measure relative output factors and these factors were compared to values reported in the literature as well as new values announced for release by Elekta. The films were exposed in the solid water phantom using an included film insert accessory. Results: Compared to the TG-21 protocol in the solid water phantom, the modified and unmodified TG-51 calibrations resulted in dose rates which were 1.8% and 1.3% lower, respectively. Ratios of the doses measured by third parties to the dose reported showed excellent agreement. MDADS returned ratios of 1.00 and 0.98 for the two TLDs irradiated. The RPC returned a mean ratio of 0.98 of the dose reported and the UPMC alanine study returned a mean ratio of 1.008. Relative output factors were found to be 0.817{+-}0.009 and 0.897{+-}0.008 for the 4 and 8 mm collimators, respectively, which are in excellent agreement with revised Monte Carlo-derived relative output factors Elekta is expected to recommend with the next version of the GK treatment planning software (GAMMAPLAN version 10). Conclusions: The TG-21 dosimetry protocol, performed in a solid water phantom in conjunction with modern dosimeters and phantom material and chamber-dependent factors, can yield an accurate dose measurement in the unique GK treatment geometry. The technique described here can be easily adopted by institutions worldwide since all equipment and instruments used are commercially available, thus reducing the existing interinstitutional variation in GK calibration techniques. Relative output factor measurements made in this same solid water phantom were used to verify the relative output factors provided by Elekta and agreed excellently with output factors expected to be released in conjunction with GAMMAPLAN version 10.

60 APPLIED LIFE SCIENCES↗

A generalized linear-quadratic model incorporating reciprocal time pattern of radiation damage repair

Purpose: It has been conventionally assumed that the repair rate for sublethal damage (SLD) remains constant during the entire radiation course. However, increasing evidence from animal studies suggest that this may not the case. Rather, it appears that the repair rate for radiation-induced SLD slows down with increasing time. Such a slowdown in repair would suggest that the exponential repair pattern would not necessarily accurately predict repair process. As a result, the purpose of this study was to investigate a new generalized linear-quadratic (LQ) model incorporating a repair pattern with reciprocal time. The new formulas were tested with published experimental data. Methods: The LQ model has been widely used in radiation therapy, and the parameter G in the surviving fraction represents the repair process of sublethal damage with T{sub r} as the repair half-time. When a reciprocal pattern of repair process was adopted, a closed form of G was derived analytically for arbitrary radiation schemes. The published animal data adopted to test the reciprocal formulas. Results: A generalized LQ model to describe the repair process in a reciprocal pattern was obtained. Subsequently, formulas for special cases were derived from this general form. The reciprocal model showed a better fit to the animal data than the exponential model, particularly for the ED50 data (reduced {chi}{sup 2}{sub min} of 2.0 vs 4.3, p = 0.11 vs 0.006), with the following gLQ parameters: {alpha}/{beta} = 2.6-4.8 Gy, T{sub r} = 3.2-3.9 h for rat feet skin, and {alpha}/{beta} = 0.9 Gy, T{sub r} = 1.1 h for rat spinal cord. Conclusions: These results of repair process following a reciprocal time suggest that the generalized LQ model incorporating the reciprocal time of sublethal damage repair shows a better fit than the exponential repair model. These formulas can be used to analyze the experimental and clinical data, where a slowing-down repair process appears during the course of radiation therapy.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Vision 20/20: Automation and advanced computing in clinical radiation oncology

This Vision 20/20 paper considers what computational advances are likely to be implemented in clinical radiation oncology in the coming years and how the adoption of these changes might alter the practice of radiotherapy. Four main areas of likely advancement are explored: cloud computing, aggregate data analyses, parallel computation, and automation. As these developments promise both new opportunities and new risks to clinicians and patients alike, the potential benefits are weighed against the hazards associated with each advance, with special considerations regarding patient safety under new computational platforms and methodologies. While the concerns of patient safety are legitimate, the authors contend that progress toward next-generation clinical informatics systems will bring about extremely valuable developments in quality improvement initiatives, clinical efficiency, outcomes analyses, data sharing, and adaptive radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric evaluation of the interplay effect in respiratory-gated RapidArc radiation therapy

Purpose: Volumetric modulated arc therapy (VMAT) with gating capability has had increasing adoption in many clinics in the United States. In this new technique, dose rate, gantry rotation speed, and the leaf motion speed of multileaf collimators (MLCs) are modulated dynamically during gated beam delivery to achieve highly conformal dose coverage of the target and normal tissue sparing. Compared with the traditional gated intensity-modulated radiation therapy technique, this complicated beam delivery technique may result in larger dose errors due to the intrafraction tumor motion. The purpose of this work is to evaluate the dosimetric influence of the interplay effect for the respiration-gated VMAT technique (RapidArc, Varian Medical Systems, Palo Alto, CA). Our work consisted of two parts: (1) Investigate the interplay effect for different target residual errors during gated RapidArc delivery using a one-dimensional moving phantom capable of producing stable sinusoidal movement; (2) Evaluate the dosimetric influence in ten clinical patients’ treatment plans using a moving phantom driven with a patient-specific respiratory curve. Methods: For the first part of this study, four plans were created with a spherical target for varying residual motion of 0.25, 0.5, 0.75, and 1.0 cm. Appropriate gating windows were applied for each. The dosimetric effect was evaluated using EDR2 film by comparing the gated delivery with static delivery. For the second part of the project, ten gated lung stereotactic body radiotherapy cases were selected and reoptimized to be delivered by the gated RapidArc technique. These plans were delivered to a phantom, and again the gated treatments were compared to static deliveries by the same methods. Results: For regular sinusoidal motion, the dose delivered to the target was not substantially affected by the gating windows when evaluated with the gamma statistics, suggesting the interplay effect has a small role in respiratory-gated RapidArc therapy. Varied results were seen when gated therapy was performed on the patient plans that could only be attributed to differences in patient respiratory patterns. Patients whose plans had the largest percentage of pixels failing the gamma statistics exhibited irregular breathing patterns including substantial interpatient variation in depth of respiration. Conclusions: The interplay effect has a limited impact on gated RapidArc therapy when evaluated with a linear phantom. Variations in patient breathing patterns, however, are of much greater clinical significance. Caution must be taken when evaluating patients’ respiratory efforts for gated arc therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-08: A Hybrid Three Dimensional Registration Framework for Image-Guided Accurate Radiotherapy System ARTS-IGRT

Purpose: The purpose of this work was to develop a registration framework and method based on the software platform of ARTS-IGRT and implement in C++ based on ITK libraries to register CT images and CBCT images. ARTS-IGRT was a part of our self-developed accurate radiation planning system ARTS. Methods: Mutual information (MI) registration treated each voxel equally. Actually, different voxels even having same intensity should be treated differently in the registration procedure. According to their importance values calculated from self-information, a similarity measure was proposed which combined the spatial importance of a voxel with MI (S-MI). For lung registration, Firstly, a global alignment method was adopted to minimize the margin error and achieve the alignment of these two images on the whole. The result obtained at the low resolution level was then interpolated to become the initial conditions for the higher resolution computation. Secondly, a new similarity measurement S-MI was established to quantify how close the two input image volumes were to each other. Finally, Demons model was applied to compute the deformable map. Results: Registration tools were tested for head-neck and lung images and the average region was 128*128*49. The rigid registration took approximately 2 min and converged 10% faster than traditional MI algorithm, the accuracy reached 1mm for head-neck images. For lung images, the improved symmetric Demons registration process was completed in an average of 5 min using a 2.4GHz dual core CPU. Conclusion: A registration framework was developed to correct patient's setup according to register the planning CT volume data and the daily reconstructed 3D CBCT data. The experiments showed that the spatial MI algorithm can be adopted for head-neck images. The improved Demons deformable registration was more suitable to lung images, and rigid alignment should be applied before deformable registration to get more accurate result. Supported by National Natural Science Foundation of China (NO.81101132) and Natural Science Foundation of Anhui Province (NO.11040606Q55)

60 APPLIED LIFE SCIENCES↗

Systematic calibration of an integrated x-ray and optical tomography system for preclinical radiation research

Purpose: The cone beam computed tomography (CBCT) guided small animal radiation research platform (SARRP) has been developed for focal tumor irradiation, allowing laboratory researchers to test basic biological hypotheses that can modify radiotherapy outcomes in ways that were not feasible previously. CBCT provides excellent bone to soft tissue contrast, but is incapable of differentiating tumors from surrounding soft tissue. Bioluminescence tomography (BLT), in contrast, allows direct visualization of even subpalpable tumors and quantitative evaluation of tumor response. Integration of BLT with CBCT offers complementary image information, with CBCT delineating anatomic structures and BLT differentiating luminescent tumors. This study is to develop a systematic method to calibrate an integrated CBCT and BLT imaging system which can be adopted onboard the SARRP to guide focal tumor irradiation. Methods: The integrated imaging system consists of CBCT, diffuse optical tomography (DOT), and BLT. The anatomy acquired from CBCT and optical properties acquired from DOT serve as a priori information for the subsequent BLT reconstruction. Phantoms were designed and procedures were developed to calibrate the CBCT, DOT/BLT, and the entire integrated system. Geometrical calibration was performed to calibrate the CBCT system. Flat field correction was performed to correct the nonuniform response of the optical imaging system. Absolute emittance calibration was performed to convert the camera readout to the emittance at the phantom or animal surface, which enabled the direct reconstruction of the bioluminescence source strength. Phantom and mouse imaging were performed to validate the calibration. Results: All calibration procedures were successfully performed. Both CBCT of a thin wire and a euthanized mouse revealed no spatial artifact, validating the accuracy of the CBCT calibration. The absolute emittance calibration was validated with a 650 nm laser source, resulting in a 3.0% difference between simulated and measured signal. The calibration of the entire system was confirmed through the CBCT and BLT reconstruction of a bioluminescence source placed inside a tissue-simulating optical phantom. Using a spatial region constraint, the source position was reconstructed with less than 1 mm error and the source strength reconstructed with less than 24% error. Conclusions: A practical and systematic method has been developed to calibrate an integrated x-ray and optical tomography imaging system, including the respective CBCT and optical tomography system calibration and the geometrical calibration of the entire system. The method can be modified and adopted to calibrate CBCT and optical tomography systems that are operated independently or hybrid x-ray and optical tomography imaging systems.

60 APPLIED LIFE SCIENCES↗

WE-AB-201-00: Treatment Planning System Commissioning and QA

Treatment planning systems (TPS) are a cornerstone of modern radiation therapy. Errors in their commissioning or use can have a devastating impact on many patients. To support safe and high quality care, medical physicists must conduct efficient and proper commissioning, good clinical integration, and ongoing quality assurance (QA) of the TPS. AAPM Task Group 53 and related publications have served as seminal benchmarks for TPS commissioning and QA over the past two decades. Over the same time, continuing innovations have made the TPS even more complex and more central to the clinical process. Medical goals are now expressed in terms of the dose and margins around organs and tissues that are delineated from multiple imaging modalities (CT, MR and PET); and even temporally resolved (i.e., 4D) imaging. This information is passed on to optimization algorithms to establish accelerator movements that are programmed directly for IMRT, VMAT and stereotactic treatments. These advances have made commissioning and QA of the TPS much more challenging. This education session reviews up-to-date experience and guidance on this subject; including the recently published AAPM Medical Physics Practice Guideline (MPPG) #5 “Commissioning and QA of Treatment Planning Dose Calculations: Megavoltage Photon and Electron Beams”. Treatment Planning System Commissioning and QA: Challenges and Opportunities (Greg Salomons) This session will provide some key background and review publications describing prominent incidents relating to TPS commissioning and QA. Traditional approaches have been hardware and feature oriented. They aim to establish a functional configuration and establish specifications for regular testing of features (like dose calculation) to assure stable operation and detect failures. With the advent of more complex systems, more patient-specific testing has also been adopted. A number of actual TPS defects will be presented along with heuristics for identifying similar defects in the future. Finally, the Gamma test has become a popular metric for reporting TPS Commissioning and QA results. It simplifies complex testing into a numerical index, but noisy data and casual application can make it misleading. A brief review of the issues around the use of the Gamma test will be presented. TPS commissioning and QA: A process orientation and application of control charts (Michael Sharpe) A framework for commissioning a treatment planning system will be presented, focusing on preparations, practical aspects of configuration, priorities, specifications, and establishing performance. The complexity of the modern TPS make modular testing of features inadequate, and modern QA tools can provide “too much information” about the performance of techniques like IMRT and VMAT. We have adopted a process orientation and quality tools, like control charts, for ongoing TPS QA and assessment of patient-specific tests. The trending nature of these tools reveals the overall performance of the TPS system, and quantifies the variations that arise from individual plans, discrete calculations, and experimentation based on discrete measurements. Examples demonstrating application of these tools to TPS QA will be presented. TPS commissioning and QA: Incorporating the entire planning process (Sasa Mutic) The TPS and its features do not perform in isolation. Instead, the features and modules are key components in a complex process that begins with CT Simulation and extends to treatment delivery, along with image guidance and verification. Most importantly, the TPS is used by people working in a multi-disciplinary environment. It is very difficult to predict the outcomes of human interactions with software. Therefore, an interdisciplinary approach to training, commissioning and QA will be presented, along with an approach to the physics chart check and end-to-end testing as a tool for TPS QA. The role of standardization and automation in QA will also be discussed. The recommendations of MPPG #5 and practical implementation strategies (Jennifer Smilowitz) The recently published recommendations from Task Group No. 244, Medical Physics Practice Guideline on Commissioning and QA of Treatment Planning Dose Calculations: Megavoltage Photon and Electron Beams will be presented. The recommendations focus on the validation of commissioning data and dose calculations. Tolerance values for non-IMRT beam configurations are summarized based on established criteria and data collected by the IROC. More stringent evaluation criteria for IMRT dose calculations are suggested to test the limitations of the TPS dose algorithms for advanced delivery conditions. The MPPG encourages users to create a suite of validation tests for dose calculation for various conditions for static photon beams, heterogeneities, IMRT/VMAT and electron beams. This test suite is intended to be used for subsequent testing, including TPS software upgrades. In the past, the recommendations of some reports have not been widely implemented due to practical limitations. Implementation strategies, tools and processes developed by multiple centers for efficient and “do-able” MPPG # 5 testing will be presented, as well as a discussion on the overall validation experience. Learning Objectives: Identify some of the key documents relevant for TPS commissioning and QA Understand strategies for testing TPS software Gain a practical knowledge of the Gamma test criteria Increase familiarity with the process of commissioning a TPS Learn about the use of Control Charts for TPS QA Review the role of the TPS in the overall planning process Increase awareness of the link between TPS QA and chart checking Gain an increased appreciation for the importance of interdisciplinary communication Understand the new recommendations from MPPG #5 on TPS Dose Algorithm Commissioning and QC/QA Learn practical implementation processes and tools for MPPG #5 validation recommendations.

60 APPLIED LIFE SCIENCES↗

WE-AB-201-01: Treatment Planning System Commissioning and QA: Challenges and Opportunities

Treatment planning systems (TPS) are a cornerstone of modern radiation therapy. Errors in their commissioning or use can have a devastating impact on many patients. To support safe and high quality care, medical physicists must conduct efficient and proper commissioning, good clinical integration, and ongoing quality assurance (QA) of the TPS. AAPM Task Group 53 and related publications have served as seminal benchmarks for TPS commissioning and QA over the past two decades. Over the same time, continuing innovations have made the TPS even more complex and more central to the clinical process. Medical goals are now expressed in terms of the dose and margins around organs and tissues that are delineated from multiple imaging modalities (CT, MR and PET); and even temporally resolved (i.e., 4D) imaging. This information is passed on to optimization algorithms to establish accelerator movements that are programmed directly for IMRT, VMAT and stereotactic treatments. These advances have made commissioning and QA of the TPS much more challenging. This education session reviews up-to-date experience and guidance on this subject; including the recently published AAPM Medical Physics Practice Guideline (MPPG) #5 “Commissioning and QA of Treatment Planning Dose Calculations: Megavoltage Photon and Electron Beams”. Treatment Planning System Commissioning and QA: Challenges and Opportunities (Greg Salomons) This session will provide some key background and review publications describing prominent incidents relating to TPS commissioning and QA. Traditional approaches have been hardware and feature oriented. They aim to establish a functional configuration and establish specifications for regular testing of features (like dose calculation) to assure stable operation and detect failures. With the advent of more complex systems, more patient-specific testing has also been adopted. A number of actual TPS defects will be presented along with heuristics for identifying similar defects in the future. Finally, the Gamma test has become a popular metric for reporting TPS Commissioning and QA results. It simplifies complex testing into a numerical index, but noisy data and casual application can make it misleading. A brief review of the issues around the use of the Gamma test will be presented. TPS commissioning and QA: A process orientation and application of control charts (Michael Sharpe) A framework for commissioning a treatment planning system will be presented, focusing on preparations, practical aspects of configuration, priorities, specifications, and establishing performance. The complexity of the modern TPS make modular testing of features inadequate, and modern QA tools can provide “too much information” about the performance of techniques like IMRT and VMAT. We have adopted a process orientation and quality tools, like control charts, for ongoing TPS QA and assessment of patient-specific tests. The trending nature of these tools reveals the overall performance of the TPS system, and quantifies the variations that arise from individual plans, discrete calculations, and experimentation based on discrete measurements. Examples demonstrating application of these tools to TPS QA will be presented. TPS commissioning and QA: Incorporating the entire planning process (Sasa Mutic) The TPS and its features do not perform in isolation. Instead, the features and modules are key components in a complex process that begins with CT Simulation and extends to treatment delivery, along with image guidance and verification. Most importantly, the TPS is used by people working in a multi-disciplinary environment. It is very difficult to predict the outcomes of human interactions with software. Therefore, an interdisciplinary approach to training, commissioning and QA will be presented, along with an approach to the physics chart check and end-to-end testing as a tool for TPS QA. The role of standardization and automation in QA will also be discussed. The recommendations of MPPG #5 and practical implementation strategies (Jennifer Smilowitz) The recently published recommendations from Task Group No. 244, Medical Physics Practice Guideline on Commissioning and QA of Treatment Planning Dose Calculations: Megavoltage Photon and Electron Beams will be presented. The recommendations focus on the validation of commissioning data and dose calculations. Tolerance values for non-IMRT beam configurations are summarized based on established criteria and data collected by the IROC. More stringent evaluation criteria for IMRT dose calculations are suggested to test the limitations of the TPS dose algorithms for advanced delivery conditions. The MPPG encourages users to create a suite of validation tests for dose calculation for various conditions for static photon beams, heterogeneities, IMRT/VMAT and electron beams. This test suite is intended to be used for subsequent testing, including TPS software upgrades. In the past, the recommendations of some reports have not been widely implemented due to practical limitations. Implementation strategies, tools and processes developed by multiple centers for efficient and “do-able” MPPG #5 testing will be presented, as well as a discussion on the overall validation experience. Learning Objectives: Identify some of the key documents relevant for TPS commissioning and QA Understand strategies for testing TPS software Gain a practical knowledge of the Gamma test criteria Increase familiarity with the process of commissioning a TPS Learn about the use of Control Charts for TPS QA Review the role of the TPS in the overall planning process Increase awareness of the link between TPS QA and chart checking Gain an increased appreciation for the importance of interdisciplinary communication Understand the new recommendations from MPPG #5 on TPS Dose Algorithm Commissioning and QC/QA Learn practical implementation processes and tools for MPPG #5 validation recommendations.

60 APPLIED LIFE SCIENCES↗