At least 1,585 records · Page 88

The impact of contaminants on laser-driven light ion acceleration

The impact of contaminants on laser-driven ion acceleration is investigated using particle-in-cell simulations. The conventional ion acceleration mechanism, target normal sheath acceleration, has been revisited for targets with proton-rich contaminants in the form of water vapor. The targets considered have a deuterated plastic layer on the rear surface of an aluminum target, and the influence of the contaminant layer on the deuteron acceleration is investigated. In the early stage of ion acceleration, the space-charge electrostatic field on the rear target surface accelerates only the outermost, proton-rich layer of ions, which inhibits the deuteron acceleration by shielding it from the field. When the proton layer is depleted, the deuterons become exposed to the space-charge field and are promptly accelerated. This scenario was tested with a two-dimensional particle-in-cell simulation model by varying the contaminant layer thickness and laser fluence (laser energy per unit area). For laser fluences F{sub laser}<1 J/{mu}m{sup 2}, the contamination layer over the surface inhibits the deuteron acceleration from the rear surface, while in the opposite case of laser fluences F{sub laser}>1 J/{mu}m{sup 2} deuterons and heavier ions can be successfully accelerated with conversion efficiency of laser energy into ions of more than 1%. Experimental data from a 6 {mu}m thick aluminum foil coated with a 1 {mu}m deuterated plastic layer on the back surface are suggestive of the detrimental role of contaminants on deuteron acceleration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of Mission Profiles for Humidity Models in the Reliability Testing of PV Inverters: Preprint

To understand the impacts of humidity on PV inverters, mission profiles were developed to accurately describe the different processes and rates based on the environmental factors of temperature, relative humidity, and irradiance. The operating environment of the device introduces stress factors dependent on component temperature, relative humidity, and component voltage. The development of profiles started from looking at historical climate conditions at Cocoa, Florida, a hot and humid location. The profile developed from field location was compared with existing humidity test profiles in industrial and military standards to determine acceleration factors. Prior to the evaluation of the mission profiles, critical components in the PV inverter were identified based on vendor discussions along with failure modes of interest. The profiles considered in this study was demonstrated using a 4-kVA string inverter. The measurements from the devices were substituted in device manufacturer specified equation to determine the severity of each test. The severity of each test was compared against the severity of the 24-hour result to determine the acceleration factor of each test. The acceleration factors were determined to be over a range of 1.2-6 for the existing humidity tests from standards, when compared against the mission profile developed from field data. This optimal humidity/thermal profile will be passed to the IEC standards development for inverter qualification testing.

humidity models↗

Aging of Concrete for the Evaluation of Repair Materials to Protect the Walls of the HCAEX Tunnel at Savannah River - 20301

H-Canyon, located in the Savannah River site, is a unique facility for chemical reprocessing of plutonium, highly-enriched uranium, and other radioactive materials. The exhaust gases of the H-Canyon are sent through the H-Canyon Exhaust (HCAEX) tunnel for contamination removal. Robotic inspections of the tunnel revealed significant degradation of the reinforced concrete structure that was associated with acid attack, and could compromise the structural stability of the tunnel. Thus, the identification and evaluation of potential repair materials that could be applied on the degraded walls to mitigate and prevent further degradation is of significant interest to the Department of Energy and the Savannah River representatives. This research effort has been divided into two phases: 1) Development and evaluation of aged concrete under accelerated aging conditions (which is the focus of this paper) and 2) Evaluation of potential repair materials applied on aged and non-aged concrete under simulated aggressive conditions. In order to develop and evaluate concrete samples exposed to accelerated aging conditions in simulated aggressive environments, a literature review of the HCAEX tunnel was conducted that included 1) characterization and extent of the concrete damage, 2) environmental conditions inside the tunnel and 3) primary deterioration mechanisms. In addition, potential coatings and/or repair materials for degraded concrete surfaces exposed to aggressive environments (primarily acidic) were selected from the literature review and the most common testing and measurements for evaluating acid attack phenomena, erosion, etc. were reviewed. From the literature review findings, a preliminary bench-scale test plan for the concrete aging was developed, including accelerated aging tests with aggressive conditions (acid fumes, humidity, etc.). Concrete samples were exposed to the aging accelerated conditions (e.g. immersion in acid solutions) and visual inspection, mass loss and pH change (acid solution) were recorded over time. Correlations between the visual inspection, mass loss and pH changes results and the aging time or the aging conditions were developed. Specimens submitted to the highest acid concentration showed the fastest and most intense degradation. The type of coarse aggregate (limestone) used for the concrete seemed to be the cause of the fastest aging observed, compared to the cement paste. The research findings created the foundation for the ongoing investigation, in which new concrete samples with a mix design similar to the HCAEX tunnel will be tested and will serve as the substrate for testing the selected coatings and /or repair materials. In this paper, the literature review and preliminary results from the aging tests are provided. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Artificial intelligence–powered biofoundries for protein engineering and metabolic engineering

Synthetic biology is rapidly evolving through the integration of artificial intelligence (AI) and automated biofoundries. This convergence accelerates the design–build–test–learn cycle, shifting protein engineering and metabolic engineering from labor-intensive manual experimentation to autonomous experimentation. This review summarizes recent advances in workflow development, AI models, and their integration with biofoundries for automated or autonomous protein engineering and metabolic engineering. Particularly, we highlight the potential of AI-powered biofoundries for accelerated scientific discovery and innovation in synthetic biology.

Chen, Junyu [Univ. of Illinois at Urbana-Champaign↗

SU-F-T-459: ArcCHECK Machine QA : Highly Efficient Quality Assurance Tool for VMAT, SRS & SBRT Linear Accelerator Delivery

Purpose: Quality assurance (QA) of complex linear accelerators is critical and highly time consuming. ArcCHECK Machine QA tool is used to test geometric and delivery aspects of linear accelerator. In this study we evaluated the performance of this tool. Methods: Machine QA feature allows user to perform quality assurance tests using ArcCHECK phantom. Following tests were performed 1) Gantry Speed 2) Gantry Rotation 3) Gantry Angle 4)MLC/Collimator QA 5)Beam Profile Flatness & Symmetry. Data was collected on trueBEAM stX machine for 6 MV for a period of one year. The Gantry QA test allows to view errors in gantry angle, rotation & assess how accurately the gantry moves around the isocentre. The MLC/Collimator QA tool is used to analyze & locate the differences between leaf bank & jaw position of linac. The flatness & Symmetry test quantifies beam flatness & symmetry in IEC-y & x direction. The Gantry & Flatness/Symmetry test can be performed for static & dynamic delivery. Results: The Gantry speed was 3.9 deg/sec with speed maximum deviation around 0.3 deg/sec. The Gantry Isocentre for arc delivery was 0.9mm & static delivery was 0.4mm. The maximum percent positive & negative difference was found to be 1.9 % & – 0.25 % & maximum distance positive & negative diff was 0.4mm & – 0.3 mm for MLC/Collimator QA. The Flatness for Arc delivery was 1.8 % & Symmetry for Y was 0.8 % & X was 1.8 %. The Flatness for gantry 0°,270°,90° & 180° was 1.75,1.9,1.8 & 1.6% respectively & Symmetry for X & Y was 0.8,0.6% for 0°, 0.6,0.7% for 270°, 0.6,1% for 90° & 0.6,0.7% for 180°. Conclusion: ArcCHECK Machine QA is an useful tool for QA of Modern linear accelerators as it tests both geometric & delivery aspects. This is very important for VMAT, SRS & SBRT treatments.

43 PARTICLE ACCELERATORS↗

Extended Pulse-Powered Humidity-Freeze Cycling for Testing Module-Level Power Electronics

An EMI suppression capacitor (polypropylene film type) failed by 'popcorning' due to vapor outgassing in pulse powered humidity-freeze cycles. No shorts or shunts could be detected despite mildly corroded metallization visible in the failed capacitor. Humidity-freeze cycling is optimized to break into moisture barriers. However, further studies will be required on additional module level power electronic (MLPE) devices to optimize the stress testing for condensation to precipitate any weakness to short circuiting and other humidity/bias failure modes.

14 SOLAR ENERGY↗

Multicloud: Multigrid convergence with a meshless operator

The primary objective of this work is to develop and test a new convergence acceleration technique we call multicloud. Multicloud is well-founded in the mathematical basis of multigrid, but relies on a meshless operator on coarse levels. The meshless operator enables extremely simple and automatic coarsening procedures for arbitrary meshes using arbitrary fine level discretization schemes. The performance of multicloud is compared with established multigrid techniques for structured and unstructured meshes for the Euler equations on two-dimensional test cases. Results indicate comparable convergence rates per unit work for multicloud and multigrid. However, because of its mesh and scheme transparency, multicloud may be applied to a wide array of problems with no modification of fine level schemes as is often required with agglomeration techniques. The implication is that multicloud can be implemented in a completely modular fashion, allowing researchers to develop fine level algorithms independent of the convergence accelerator for complex three-dimensional problems.

97 MATHEMATICS AND COMPUTING↗

HTS Dipole Magnet With Mechanical Energy Transfer in the Magnetic Field

Several high-temperature superconducting (HTS) model magnets for particle accelerators were designed and successfully tested at Fermilab. Some worked in a persistent current mode by continuously generating magnetic fields in the iron-dominated magnet gap. This paper investigated a novel HTS dipole magnet concept with a mechanical energy transfer in the magnetic field. To pump the energy in the superconducting HTS dipole magnet, a detachable magnetizer was used. The HTS dipole magnet was built and successfully tested at a liquid nitrogen temperature. We discuss the magnet design, test results, the proposed approach limits, and efficiency.

43 PARTICLE ACCELERATORS↗

A high efficiency and low vibration liquid nitrogen cooling system for silicon crystal based x-ray optics

A compact low-cost cryocooling system has been designed, constructed, and tested at SLAC National Accelerator Laboratory. The cooling power is provided by natural convection and phase change of the liquid nitrogen. The initial application was to cool silicon crystal optics to the sub-100 K range. A silicon crystal of dimension (width × depth × height) 50 × 50 × 30 mm3 has been used with an electric heater on the top surface in this prototyping test. This system can effectively provide more than 80 W of cooling power to the optics with a consumption of liquid nitrogen less than 2.1 l/h. The vibration of the silicon crystal was monitored during the tests with added electric heater power on the crystal. We note the vibration of the silicon crystal due to liquid nitrogen boiling is negligible.

47 OTHER INSTRUMENTATION↗

In situ baking method for degassing of a kicker magnet in accelerator beam line

In this study, the authors propose a new in situ degassing method by which only kicker magnets in the accelerator beam line are baked out without raising the temperature of the vacuum chamber to prevent unwanted thermal expansion of the chamber. By simply installing the heater and thermal radiation shield plates between the kicker magnet and the chamber wall, most of the heat flux from the heater directs toward the kicker magnet. The result of the verification test showed that each part of the kicker magnet was heated to above the target temperature with a small rise in the vacuum chamber temperature. A graphite heater was selected in this application to bake-out the kicker magnet in the beam line to ensure reliability and easy maintainability of the heater. The vacuum characteristics of graphite were suitable for heater operation in the beam line. A preliminary heat-up test conducted in the accelerator beam line also showed that each part of the kicker magnet was successfully heated and that thermal expansion of the chamber was negligibly small.

43 PARTICLE ACCELERATORS↗

Centrifuge modeling of lateral bearing behavior of offshore wind turbine with suction bucket foundation in sand

Suction bucket foundation is a promising alternative for offshore wind turbine foundations. The lateral bearing behavior and failure mechanism are significant topics for optimizing its design criteria. In this study, a group of centrifuge tests were performed to investigate the lateral bearing capacity of suction bucket foundation with three aspect ratios. Force-controlled lateral static and cyclic tests were performed at a centrifuge acceleration of 50g. Four soil conditions were considered in centrifuge tests with a combination of loose/dense and dry/saturated sand. The load-displacement and the stiffness-displacement relationships are presented in the paper, and it is concluded that the lateral bearing capacity can be reached when the normalized lateral displacement (displacement divided by the bucket diameter) reached 3% as the first method. Displacement rates are plotted against the lateral load to give the second method for defining the ultimate lateral capacity. In cyclic tests, the lateral displacement and stiffness are correlated to the cycle numbers in the first 5 cycles, but the change is less apparent in the rest. The results demonstrated the behavior of bucket foundation in service conditions. Finally, a simplified calculation method is used as the third method and checked with tests results.

17 WIND ENERGY↗

Federal Emergency Management Agency Mobile Housing Unit Running Gear Testing (Final Report)

The Federal Emergency Management Agency (FEMA) stages manufactured housing units (MHUs) at key locations to be used during disasters when other housing accommodations cannot be arranged for individuals or families. Due to the unpredictability of natural disasters and the limitations of the manufactured housing industry to produce large numbers of MHUs in very short periods of time, it is necessary for FEMA to store a large number of units for many months or years. With these long storage periods come degradation issues with frames, tires, bearing, and braking systems. These types of issues are also of interest to the U.S. Department of Transportation (DOT) Federal Motor Carrier Safety Administration (FMCSA) because regulated carriers normally transport these units and 49 CFR 393.75 Tires specifies tire loading restrictions for manufactured homes. To compare the running gear (tires, brakes, drums, bearings, axles, springs, and spring mounting hardware) currently specified in the 2014 Rugged Based Performance Requirements (RBPR) and the newly recommended running gear specified in the upcoming revision to the RBPR, the Oak Ridge National Laboratory (ORNL) outlined a Longevity Test Plan, which focused on the assessment of component longevity (failure rates by component type). The Test Plan also studied the forces imparted to the MHU from the running gear from interaction with the roadway for both the running gear in the 2014 RBPR and the running gear specified in the upcoming RBPR revision. Since the assessment of component longevity and failures are also issues of concern for FMCSA, both agencies collaborated to support the research presented in this report. The tests and data collection were conducted at the Navistar Proving Grounds (NPG) in New Carlisle (near South Bend), Indiana, during the May-November 2018 period. Four alternatives for the suspension system of a typical three-bedroom MHU were considered in this test. Alternative 0 was the MHU that was selected from the FEMA staging area in Selma, Alabama. Empirical data had shown that, on average, this alternative experiences one tire failure every 150 miles (or 0.0067 tire failures per mile traveled). Before testing, Alternative 0 was equipped with similar running gear hardware, although in new condition and installed following the manufacturer’s specifications. This became the Baseline Unit, or Alternative 1. Another unit, also selected from the FEMA staging area in Selma, Alabama, was equipped with better axles (i.e., axles that were rated for 7,000lbs as opposed to 6,000lbs for the Baseline Unit) and better tires. This became the Upgrade Unit, or Alternative 2. At the end of the Longevity Test, the Upgrade Unit was mounted with radial tires. This became Alternative 3.Alternative 1 (Baseline Unit) had, on average, one tire failure every 251 miles (or 0.0040 tire failures per mile traveled). So, by simply following the correct manufacturer’s specifications for the assembly of the transportation system, a reduction of 41% in the per mile tire failure was achieved. In the same test, Alternative 2 (Upgrade Unit) showed, on average, one tire failure every 728 miles traveled (or 0.0014 tire failure s per mile traveled). When the Upgrade Unit was mounted with radial tires in the last part of the test, no tire failures were observed for the 2,400 miles tested. That is, in the case of the radial tires (Alternative 3) the tire failure was less than one per 2,400 miles traveled (or less than 0.0004 tire failures per mile traveled). The data collected for the Longevity Test showed that the maximum accelerations were registered in all cases at the center of the MHU in the vertical direction. The overall maximum was registered by the Baseline Unit, Alternative 1. If that value is normalized to 100%, then the Upgrade Unit (Alternative 2) showed, on average, 81% at the same location, and Alternative 3 (radial-tire test) 59%. That is, the upgraded transportation system showed a reduction of 19% and 41% in the vertical accelerations transmitted to MHU at its center when regular and radial tires, respectively, were used. As part of the Test Protocol, NPG conducted a visual inspection of the MHUs and transportation system at the end of each test day. ORNL reviewed all the inspection reports in an attempt to determine if there was any difference in the damage that the Baseline and Upgrade MHUs showed during the test. The Upgrade Unit always showed lower accelerations transmitted to the MHU than the Baseline Unit. In most cases, these differences were statistically significant. The FEMA inspection report, conducted by a FEMA certified inspector at the end of the tests, included a shorter list of damaged items for the Baseline Unit than for the Upgrade Unit, although similar type of damages was described for both units. This may be an indication that, although lower than those of the Baseline Unit, the accelerations transmitted by the Upgrade Unit were above the threshold at which MHU elements start to fail.

42 ENGINEERING↗

Accelerated Self-Healing and Property Recovery in Brush Particle Solids Featuring Brush Dispersity

Brush particles, hybrid materials consisting of polymer chains tethered to particle surfaces, offer tunable properties that make them promising candidates for advanced functional materials. This study investigated the role of chain dispersity in the viscoelastic self-healing of poly (methyl acrylate) (PMA)-based brush particle solids. Increasing the molecular weight dispersity of grafted chains significantly enhanced both strain-to-fracture and toughness of brush particle solids, while the elastic modulus and glass transition temperature were independent of chain dispersity. Cut-and-adhere testing revealed a significant acceleration of the rate of toughness recovery in high-dispersity systems as compared to low-dispersity analogs for which toughness recovery markedly lagged the recovery of Young’s modulus. The results suggest that structure and property recovery in brush particle solids are sensitive to the dynamical heterogeneity of brush canopies and highlight the role of molecular weight dispersity as a design parameter to enable hybrid materials with advanced self-healing ability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of Mid-Level Ethanol Blends on Conventional Vehicle Emissions

Tests were conducted in 2008 on 16 late-model conventional vehicles (1999-2007) to determine short-term effects of mid-level ethanol blends on performance and emissions. Vehicle odometer readings ranged from 10,000 to 100,000 miles, and all vehicles conformed to federal emissions requirements for their federal certification level. The LA92 drive cycle, also known as the Unified Cycle, was used for testing because it more accurately represents real-world acceleration rates and speeds than the Federal Test Procedure. Test fuels were splash-blends of up to 20 volume percent ethanol with federal certification gasoline. Both regulated and unregulated air-toxic emissions were measured. For the 16-vehicle fleet, increasing ethanol content resulted in reductions in average composite emissions of both nonmethane hydrocarbons and carbon monoxide and increases in average emissions of ethanol and aldehydes.

09 BIOMASS FUELS↗

Auto Stop-Start Fuel Consumption Benefits

With increasingly stringent regulations mandating the improvement of vehicle fuel economy, automotive manufacturers face growing pressure to develop and implement technologies that improve overall system efficiency. One such technology is an automatic (auto) stop-start feature. Auto stop-start reduces idle time and reduces fuel use by temporarily shutting the engine off when the vehicle comes to a stop and automatically re-starting it when the brake is released, or the accelerator is pressed. As mandated by the U.S. Congress, the U.S. Environmental Protection Agency (EPA) is required to keep the public informed about fuel saving practices. This is done, in partnership with the U.S. Department of Energy (DOE), through the fueleconomy.gov website. The “Fuel-Saving Technologies” and “Gas Mileage Tips” sections of the website are focused on helping the public make informed purchasing decisions and encouraging fuel-saving driving habits. Here, in order to provide users with accurate information about the auto stop-start feature, experiments were conducted to determine its fuel economy effect. Four vehicles were tested both with and without the feature enabled under three test cycles: the Federal Test Procedure (FTP) city fuel economy test, the US06 high acceleration aggressive driving schedule that is often identified as the “Supplemental FTP” driving schedule, and the EPA New York City Cycle (NYCC). The results were compared to measure the fuel economy and consumption effects of using the auto stop-start feature. It was found that the fuel economy improvement varied significantly between drive cycles depending on the amount and percentage of idle time during the test. The largest fuel economy improvements were 7.27% and 26.4% for the FTP and NYCC, respectively.

33 ADVANCED PROPULSION SYSTEMS↗

Lower-Energy Energy Storage System (LEESS) Component Evaluation

Alternate hybrid electric vehicle (HEV) energy storage systems (ESS) such as lithium-ion capacitors (LICs) and electrochemical double-layer capacitor (EDLC) modules have the potential for improved life, superior cold temperature performance, and lower long-term cost projections relative to traditional battery storage systems. If such lower-energy ESS (LEESS) devices can also be shown to maintain high HEV fuel savings, future HEVs designed with these devices could have an increased value proposition relative to conventional vehicles. NREL's vehicle test platform is helping validate the in-vehicle performance capability of alternative LEESS devices and identify unforeseen issues. NREL created the Ford Fusion Hybrid test platform for in-vehicle evaluation of such alternative LEESS devices, bench testing of the initial LIC pack, integration and testing of the LIC pack in the test vehicle, and bench testing and installation of an EDLC module pack. EDLC pack testing will continue in FY15. The in-vehicle LIC testing results suggest technical viability of LEESS devices to support HEV operation. Several LIC configurations tested demonstrated equivalent fuel economy and acceleration performance as the production nickel-metal-hydride ESS configuration across all tests conducted. The lowest energy LIC scenario demonstrated equivalent performance over several tests, although slightly higher fuel consumption on the US06 cycle and slightly slower acceleration performance. More extensive vehicle-level calibration may be able to reduce or eliminate these performance differences. The overall results indicate that as long as critical attributes such as engine start under worst case conditions can be retained, considerable ESS downsizing may minimally impact HEV fuel savings.

25 ENERGY STORAGE↗

Impact of Testing Method on Safety Assessment of Aged Li-Ion Cells: Part II – Aged Cells Without Li Plating

Understanding the safety profile of aged Li-ion batteries is essential for developing effective battery management and hazard mitigation strategies. However, most safety assessments have focused on fresh batteries, with just a few calorimetry studies on aged batteries with metal oxide positive electrodes. This study provides a broad assessment of commercial 18650-type Li-ion batteries with NCA, NMC, and LFP positive electrodes, both uncycled and aged under conditions that promoted solid electrolyte interphase (SEI) growth as the dominant degradation mechanism. The cells underwent mechanical (nail penetration, crush), electrical (overcharge, overdischarge), and thermal (accelerating rate calorimetry) abuse tests. Safety was rated on general characteristics such as mass loss, maximum temperature, and EUCAR (European Council for Automotive R&D) hazard level, as well as characteristics specific to individual abuse tests. Generally, aged cells with SEI growth exhibited similar or improved safety compared to uncycled cells, contrasting with our previous findings on NCA cells with Li plating as the dominant aging mechanism (Part I of this series). Yet, some tests and characteristics indicated reduced aged cell safety, such as earlier triggering of mechanical failure. These results emphasize the need to examine aged battery safety across diverse empirical techniques, degradation modes, and chemistries.

Lithium-ion cells↗

Evolution of dislocation substructures in metals via high-strain-rate nanoindentation

Deformation at high strain rates often results in high stresses on many engineering materials, potentially leading to catastrophic failure without proper design. High-strain-rate mechanical testing is thus needed to improve the design of future structural materials for a wide range of applications. Although several high-strain-rate mechanical testing techniques have been developed to provide a fundamental understanding of material responses and microstructural evolution under high-strain-rate deformation conditions, these tests are often very time consuming and costly. In this work, we utilize a high-strain-rate nanoindentation testing technique and system in combination with transmission electron microscopy to reveal the deformation mechanisms and dislocation substructures that evolve in pure metals from low (10 –2 s –1 ) to very high indentation strain rates (10 4 s –1 ), using face-centered cubic aluminum and body-centered cubic molybdenum as model materials. The results help to establish the conditions under which micro- and macro-scale tests can be compared with validity and also provide a promising pathway that could lead to accelerated high-strain-rate testing at substantially reduced costs.

36 MATERIALS SCIENCE↗