Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerators, Computing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Enhancing predictive capabilities in fusion burning plasmas through surrogate-based optimization in core transport solvers

Abstract This work presents the PORTALS framework (Rodriguez-Fernandez et al 2022 Nucl. Fusion 62 076036), which leverages surrogate modeling and optimization techniques to enable the prediction of core plasma profiles and performance with nonlinear gyrokinetic simulations at significantly reduced cost, with no loss of accuracy. The efficiency of PORTALS is benchmarked against standard methods, and its full potential is demonstrated on a unique, simultaneous 5-channel (electron temperature, ion temperature, electron density, impurity density and angular rotation) prediction of steady-state profiles in a DIII-D ITER Similar Shape plasma with GPU-accelerated, nonlinear CGYRO (Candy et al 2016 J. Comput. Phys. 324 73–93). This paper also provides general guidelines for accurate performance predictions in burning plasmas and the impact of transport modeling in fusion pilot plants studies.

Physics↗

Explicit structure-preserving geometric particle-in-cell algorithm in curvilinear orthogonal coordinate systems and its applications to whole-device 6D kinetic simulations of tokamak physics

Explicit structure-preserving geometric particle-in-cell (PIC) algorithm in curvilinear orthogonal coordinate systems is developed. The work reported represents a further development of the structure-preserving geometric PIC algorithm achieving the goal of practical applications in magnetic fusion research. The algorithm is constructed by discretizing the field theory for the system of charged particles and electromagnetic field using Whitney forms, discrete exterior calculus, and explicit non-canonical symplectic integration. In addition to the truncated infinitely dimensional symplectic structure, the algorithm preserves exactly many important physical symmetries and conservation laws, such as local energy conservation, gauge symmetry and the corresponding local charge conservation. As a result, the algorithm possesses the long-term accuracy and fidelity required for first-principles-based simulations of the multiscale tokamak physics. The algorithm has been implemented in the SymPIC code, which is designed for high-efficiency massively-parallel PIC simulations in modern clusters. The code has been applied to carry out whole-device 6D kinetic simulation studies of tokamak physics. A self-consistent kinetic steady state for fusion plasma in the tokamak geometry is numerically found with a predominately diagonal and anisotropic pressure tensor. The state also admits a steady-state sub-sonic ion flow in the range of 10 km s -1 , agreeing with experimental observations and analytical calculations Kinetic ballooning instability in the self-consistent kinetic steady state is simulated. It is shown that high-n ballooning modes have larger growth rates than low-n global modes, and in the nonlinear phase the modes saturate approximately in 5 ion transit times at the 2% level by the E × B flow generated by the instability. These results are consistent with early and recent electromagnetic gyrokinetic simulations.

43 PARTICLE ACCELERATORS↗

Coincident learning for unsupervised anomaly detection of scientific instruments

Abstract Anomaly detection is an important task for complex scientific experiments and other complex systems (e.g. industrial facilities, manufacturing), where failures in a sub-system can lead to lost data, poor performance, or even damage to components. While scientific facilities generate a wealth of data, labeled anomalies may be rare (or even nonexistent), and expensive to acquire. Unsupervised approaches are therefore common and typically search for anomalies either by distance or density of examples in the input feature space (or some associated low-dimensional representation). This paper presents a novel approach called coincident learning for anomaly detection (CoAD), which is specifically designed for multi-modal tasks and identifies anomalies based on coincident behavior across two different slices of the feature space. We define an unsupervised metric, F ^ β , out of analogy to the supervised classification F β statistic. CoAD uses F ^ β to train an anomaly detection algorithm on unlabeled data , based on the expectation that anomalous behavior in one feature slice is coincident with anomalous behavior in the other. The method is illustrated using a synthetic outlier data set and a MNIST-based image data set, and is compared to prior state-of-the-art on two real-world tasks: a metal milling data set and our motivating task of identifying RF station anomalies in a particle accelerator.

43 PARTICLE ACCELERATORS↗

Integrable symplectic maps with a polygon tessellation

Identifying integrable dynamics remains a formidable challenge, and despite centuries of research, only a handful of examples are known to date. In this article, we explore a distinct form of area-preserving (symplectic) mappings derived from the stroboscopic Poincaré cross section of a kicked rotator—an oscillator subjected to an external force periodically switched on in short pulses. The significance of this class of problems extends to various applications in physics and mathematics, including particle accelerators, crystallography, and studies of chaos. Notably, Suris's theorem constrains the integrability within this category of mappings, outlining potential scenarios with analytic invariants of motion. In this paper, we challenge the assumption of the analyticity of the invariant by exploring piecewise linear transformations on a torus ( T 2 ) and associated systems on the plane ( R 2 ), incorporating arithmetic quasiperiodicity and discontinuities. Introducing a new automated technique, we discovered previously unknown scenarios featuring polygonal invariants that form perfect tessellations and, moreover, fibrations of the plane or torus. This work reveals a novel category of planar tilings characterized by discrete symmetries that emerge from the invertibility of transformations and are intrinsically linked to the presence of integrability. Our algorithm relies on the analysis of the Poincaré rotation number and its piecewise monotonic nature for integrable cases, contrasting with the noisy behavior in the case of chaos, thereby allowing for clear separation. Some of the newly discovered systems exhibit the peculiar behavior of “integrable diffusion,” characterized by infinite and quasirandom hopping between tiles while being confined to a set of invariant segments. Finally, through the implementation of a smoothening procedure, all mappings can be generalized to quasi-integrable scenarios with suppressed volume occupied by chaotic trajectories, thereby opening doors to potential practical applications. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Physics-constrained superresolution diffusion for six-dimensional phase space diagnostics

Adaptive physics-constrained superresolution diffusion is developed for noninvasive virtual diagnostics of the six-dimensional (6D) phase space density of charged particle beams. An adaptive variational autoencoder embeds initial beam condition images and scalar measurements to a low-dimensional latent space from which a 32 6 pixel 6D tensor representation of the beam's 6D phase space density is generated. Projecting from a 6D tensor generates physically consistent two-dimensional projections. Physics-guided superresolution diffusion transforms low-resolution images of the 6D density to high resolution 256 × 256 pixel images. Unsupervised adaptive latent space tuning enables tracking of time-varying beams without knowledge of time-varying initial conditions. The method is demonstrated with experimental data and multiparticle simulations at the HiRES UED. The general approach is applicable to a wide range of complex dynamic systems evolving in high-dimensional phase space. The method is shown to be robust to distribution shift without retraining. Published by the American Physical Society 2025

43 PARTICLE ACCELERATORS↗

Model-independent particle accelerator tuning

We present a new model-independent dynamic feedback technique, rotation rate tuning, for automatically and simultaneously tuning coupled components of uncertain, complex systems. The main advantages of the method are: 1) It has the ability to handle unknown, time-varying systems, 2) It gives known bounds on parameter update rates, 3) We give an analytic proof of its convergence and its stability, and 4) It has a simple digital implementation through a control system such as the Experimental Physics and Industrial Control System (EPICS). Because this technique is model independent it may be useful as a real-time, in-hardware, feedback-based optimization scheme for uncertain and time-varying systems. In particular, it is robust enough to handle uncertainty due to coupling, thermal cycling, misalignments, and manufacturing imperfections. As a result, it may be used as a fine-tuning supplement for existing accelerator tuning/control schemes. We present multi-particle simulation results demonstrating the scheme’s ability to simultaneously adaptively adjust the set points of twenty two quadrupole magnets and two RF buncher cavities in the Los Alamos Neutron Science Center Linear Accelerator’s transport region, while the beam properties and RF phase shift are continuously varying. The tuning is based only on beam current readings, without knowledge of particle dynamics. We also present an outline of how to implement this general scheme in software for optimization, and in hardware for feedback-based control/tuning, for a wide range of systems.

42 ENGINEERING↗

Latent diffusion can map beam loss to two-dimensional phase-space projections

Beam loss monitors (BLMs) and beam current monitors (BCMs) are ubiquitous at particle accelerators around the world. These simple devices provide noninvasive high-level beam measurements but give no insight into the detailed 6D (𝑥,𝑦,𝑧,𝑝 𝑥 ,𝑝 𝑦 ,𝑝 𝑧 ) beam phase-space distributions or dynamics. We show that generative conditional latent diffusion models can learn intricate patterns to solve the extreme inverse problem of mapping waveforms of tens of BLMs or BCMs along an accelerator to detailed 2D projections of a charged particle beam’s 6D phase-space density. This transformational method can be used at any particle accelerator to transform simple noninvasive devices into detailed beam phase-space diagnostics. We demonstrate this concept via multiparticle simulations of the high-intensity beam in the kilometer-long Los Alamos Neutron Science Center linear proton accelerator.

43 PARTICLE ACCELERATORS↗

SU-E-J-126: Respiratory Gating Quality Assurance: A Simple Method to Achieve Millisecond Temporal Resolution

Purpose: Low temporal latency between a gating on/off signal and a linac beam on/off during respiratory gating is critical for patient safety. Although, a measurement of temporal lag is recommended by AAPM Task Group 142 for commissioning and annual quality assurance, there currently exists no published method. Here we describe a simple, inexpensive, and reliable method to precisely measure gating lag at millisecond resolutions. Methods: A Varian Real-time Position Management™ (RPM) gating simulator with rotating disk was modified with a resistive flex sensor (Spectra Symbol) attached to the gating box platform. A photon diode was placed at machine isocenter. Output signals of the flex sensor and diode were monitored with a multichannel oscilloscope (Tektronix™ DPO3014). Qualitative inspection of the gating window/beam on synchronicity were made by setting the linac to beam on/off at end-expiration, and the oscilloscope's temporal window to 100 ms to visually examine if the on/off timing was within the recommended 100-ms tolerance. Quantitative measurements were made by saving the signal traces and analyzing in MatLab™. The on and off of the beam signal were located and compared to the expected gating window (e.g. 40% to 60%). Four gating cycles were measured and compared. Results: On a Varian TrueBeam™ STx linac with RPM gating software, the average difference in synchronicity at beam on and off for four cycles was 14 ms (3 to 30 ms) and 11 ms (2 to 32 ms), respectively. For a Varian Clinac™ 21EX the average difference at beam on and off was 127 ms (122 to 133 ms) and 46 ms (42 to 49 ms), respectively. The uncertainty in the synchrony difference was estimated at ±6 ms. Conclusion: This new gating QA method is easy to implement and allows for fast qualitative inspection and quantitative measurements for commissioning and TG-142 annual QA measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-252: On the Evaluation of Patient Specific IMRT QA Using EPID, Dynalog Files and Patient Anatomy

Purpose: This research, investigates the viability of using the Electronic portal imaging device (EPID) coupled with the treatment planning system (TPS), to calculate the doses delivered and verify agreement with the treatment plan. The results of QA analysis using the EPID, Delta4 and fluence calculations using the multi-leaf collimator (MLC) dynalog files on 10 IMRT patients are presented in this study. Methods: EPID Fluence Images in integrated mode and Dynalog files for each field were acquired for 10 IMRT (6MV) patients and processed through an in house MatLab program to create an opening density matrix (ODM) which was used as the input fluence for dose calculation with the TPS (Pinnacle3, Philips). The EPID used in this study was the aSi1000 Varian on a Novalis TX linac equipped with high definition MLC. The resulting dose distributions were then exported to VeriSoft (PTW) where a 3D gamma was calculated using 3mm-3% criteria. The Scandidos Delta4 phantom was also used to measure a 2D dose distribution for all 10 patients and a 2D gamma was calculated for each patient using the Delta4 software. Results: The average 3D gamma for all 10 patients using the EPID images was 98.2% ± 2.6%. The average 3D gamma using the dynalog files was 94.6% ± 4.9%. The average 2D gamma from the Delta4 was 98.1% ± 2.5%. The minimum 3D gamma for the EPID and dynalog reconstructed dose distributions was found on the same patient which had a very large PTV, requiring the jaws to open to the maximum field size. Conclusion: Use of the EPID, combined with a TPS is a viable method for QA of IMRT plans. A larger ODM size can be implemented to accommodate larger field sizes. An adaptation of this process to Volumetric Arc Therapy (VMAT) is currently under way.

60 APPLIED LIFE SCIENCES↗

SU-E-T-142: Automatic Linac Log File: Analysis and Reporting

Purpose: End to end QA for IMRT/VMAT is time consuming. Automated linac log file analysis and recalculation of daily recorded fluence, and hence dose, distribution bring this closer. Methods: Matlab (R2014b, Mathworks) software was written to read in and analyse IMRT/VMAT trajectory log files (TrueBeam 1.5, Varian Medical Systems) overnight, and are archived on a backed-up network drive (figure). A summary report (PDF) is sent by email to the duty linac physicist. A structured summary report (PDF) for each patient is automatically updated for embedding into the R&V system (Mosaiq 2.5, Elekta AG). The report contains cross-referenced hyperlinks to ease navigation between treatment fractions. Gamma analysis can be performed on planned (DICOM RTPlan) and treated (trajectory log) fluence distributions. Trajectory log files can be converted into RTPlan files for dose distribution calculation (Eclipse, AAA10.0.28, VMS). Results: All leaf positions are within +/−0.10mm: 57% within +/−0.01mm; 89% within 0.05mm. Mean leaf position deviation is 0.02mm. Gantry angle variations lie in the range −0.1 to 0.3 degrees, mean 0.04 degrees. Fluence verification shows excellent agreement between planned and treated fluence. Agreement between planned and treated dose distribution, the derived from log files, is very good. Conclusion: Automated log file analysis is a valuable tool for the busy physicist, enabling potential treated fluence distribution errors to be quickly identified. In the near future we will correlate trajectory log analysis with routine IMRT/VMAT QA analysis. This has the potential to reduce, but not eliminate, the QA workload.

60 APPLIED LIFE SCIENCES↗

SU-E-T-277: Dose Calculation Comparisons Between Monaco, Pinnacle and Eclipse Treatment Planning Systems

Purpose: Monaco treatment planning system (TPS) version 5.0 uses a Monte-Carlo based dose calculation engine. The aim of this study is to verify and compare the Monaco based dose calculations with both Pinnacle{sup 3} collapsed cone convolution superposition (CCC) and Eclipse analytical anisotropic algorithm (AAA) calculations. Methods: For this study, previously treated SBRT lung, head and neck and abdomen patients were chosen to compare dose calculations between Pinnacle, Monaco and Eclipse. Plans were chosen from those that had been treated using the Elekta VersaHD or a NovalisTX linac. The plans included 3D conventional and IMRT beams using 6MV and 6MV Flattening filter free (FFF) photon beams. The original plans calculated with CCCS or AAA along with the recalculated ones using MC from the three TPS were exported into Velocity software for inter-comparison. Results: To compare the dose calculations, Mean Lung Dose (MLD), lung V5 and V20 values, and PTV Heterogeneity indexes (HI) and Conformity indexes (CI) were all calculated and recorded from the dose volume histograms (DVH). For each patient, the CI values were identical but there were differences in all other parameters. The HI was computed higher by 5 and 4% for calculated plans AAA and CCCS respectively, compared to the MC ones. The DVH graphs showed large differences between the CCCS and AAA and Monaco for 3D FFF, VMAT and IMRT plans. Better DVH agreement between was observed for 3D conventional plans. Conclusion: Better agreement was observed between CCCS and MC calculations than AAA and MC calculations. Those differences were more profound as the field size was decreasing and in the presence of inhomogeneities.

60 APPLIED LIFE SCIENCES↗

TU-A-304-01: Introduction and Workflow of Image-Guided SBRT

Increased use of SBRT and hypo fractionation in radiation oncology practice has posted a number of challenges to medical physicist, ranging from planning, image-guided patient setup and on-treatment monitoring, to quality assurance (QA) and dose delivery. This symposium is designed to provide updated knowledge necessary for the safe and efficient implementation of SBRT in various linac platforms, including the emerging digital linacs equipped with high dose rate FFF beams. Issues related to 4D CT, PET and MRI simulations, 3D/4D CBCT guided patient setup, real-time image guidance during SBRT dose delivery using gated/un-gated VMAT or IMRT, and technical advancements in QA of SBRT (in particular, strategies dealing with high dose rate FFF beams) will be addressed. The symposium will help the attendees to gain a comprehensive understanding of the SBRT workflow and facilitate their clinical implementation of the state-of-art imaging and planning techniques. Learning Objectives: Present background knowledge of SBRT, describe essential requirements for safe implementation of SBRT, and discuss issues specific to SBRT treatment planning and QA. Update on the use of multi-dimensional (3D and 4D) and multi-modality (CT, beam-level X-ray imaging, pre- and on-treatment 3D/4D MRI, PET, robotic ultrasound, etc.) for reliable guidance of SBRT. Provide a comprehensive overview of emerging digital linacs and summarize the key geometric and dosimetric features of the new generation of linacs for substantially improved SBRT. Discuss treatment planning and quality assurance issues specific to SBRT. Research grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-F-J-145: MRI-Guided Interventional Boost Radiotherapy for Rectal Cancer: Investigating the Feasibility of Adapting the Anatomy

Purpose: The recent development of an MRI-linac allows adaptation of treatments to the anatomy of the moment. This anatomy, in turn, could be altered into a more favorable situation for radiotherapy purposes. The purpose of this study is to investigate the potential dosimetric benefits of manipulating rectal anatomy in MRI-guided interventional external-beam radiotherapy for rectal cancer. Methods: For this retrospective analysis, four patients (1M/3F) diagnosed with rectal cancer were included. These underwent MR-imaging using sonography transmission gel as endorectal contrast at time of diagnosis and standard, non-contrast, MR-imaging prior to radiotherapy planning. In the contrast scan, the rectum is inflated by the inserted contrast gel, thereby potentially increasing the distance between tumor and the organs-at-risk (OAR). Both anatomies were delineated and 7- beam IMRT-plans were calculated for both situations (RT-standard and RT-inflated), using in-house developed treatment planning software. Each plan was aimed to deliver 15Gy to the planning target volume (PTV; tumor+3mm margin) with a D99>95% and Dmax<120% of the planned dose. The D2cc dose to the OAR were then compared for both situations. Results: At equal (or better) target coverage, we found a mean reduction in D2cc of 4.1Gy/237% [range 2.6Gy–6.3Gy/70%–621%] for the bladder and of 2.0Gy/145% [range −0.7Gy–7.9Gy/−73%–442%] for the small-bowel, for the RT-inflated compared to the RT-standard plans. For the three female patients, a reduction in D2cc of 5.2Gy/191% [range 3.2Gy–9.2Gy/44%–475%] for the gynecological organs was found. We found all D2cc doses to be better for the RT-inflated plans, except for one patient for whom the bladder D2cc dose was slightly increased. Conclusion: Reduction of OAR dose by manipulation of anatomy is feasible. Inflation of the rectum results in more distance between OAR and PTV. This leads to a substantial reduction in dose to OAR at equal or better target coverage.

60 APPLIED LIFE SCIENCES↗

SU-F-T-308: Mobius FX Evaluation and Comparison Against a Commercial 4D Detector Array for VMAT Plan QA

Purpose: To evaluate the use of MobiusFX as a pre-treatment verification IMRT QA tool and compare it with a commercial 4D detector array for VMAT plan QA. Methods: 15 VMAT plan QA of different treatment sites were delivered and measured by traditional means with the 4D detector array ArcCheck (Sun Nuclear corporation) and at the same time measurement in linac treatment logs (Varian Dynalogs files) were analyzed from the same delivery with MobiusFX software (Mobius Medical Systems). VMAT plan QAs created in Eclipse treatment planning system (Varian) in a TrueBeam linac machine (Varian) were delivered and analyzed with the gamma analysis routine from SNPA software (Sun Nuclear corporation). Results: Comparable results in terms of the gamma analysis with 99.06% average gamma passing with 3%,3mm passing rate is observed in the comparison among MobiusFX, ArcCheck measurements, and the Treatment Planning System dose calculated. When going to a stricter criterion (1%,1mm) larger discrepancies are observed in different regions of the measurements with an average gamma of 66.24% between MobiusFX and ArcCheck. Conclusion: This work indicates the potential for using MobiusFX as a routine pre-treatment patient specific IMRT method for quality assurance purposes and its advantages as a phantom-less method which reduce the time for IMRT QA measurement. MobiusFX is capable of produce similar results of those by traditional methods used for patient specific pre-treatment verification VMAT QA. Even the gamma results comparing to the TPS are similar the analysis of both methods show that the errors being identified by each method are found in different regions. Traditional methods like ArcCheck are sensitive to setup errors and dose difference errors coming from the linac output. On the other hand linac log files analysis record different errors in the VMAT QA associated with the MLCs and gantry motion that by traditional methods cannot be detected.

60 APPLIED LIFE SCIENCES↗

SU-F-T-494: A Multi-Institutional Study of Independent Dose Verification Using Golden Beam Data

Purpose: In general, beam data of individual linac is measured for independent dose verification software program and the verification is performed as a secondary check. In this study, independent dose verification using golden beam data was compared to that using individual linac’s beam data. Methods: Six institutions were participated and three different beam data were prepared. The one was individual measured data (Original Beam Data, OBD) .The others were generated by all measurements from same linac model (Model-GBD) and all linac models (All-GBD). The three different beam data were registered to the independent verification software program for each institute. Subsequently, patient’s plans in eight sites (brain, head and neck, lung, esophagus, breast, abdomen, pelvis and bone) were analyzed using the verification program to compare doses calculated using the three different beam data. Results: 1116 plans were collected from six institutes. Compared to using the OBD, the results shows the variation using the Model-GBD based calculation and the All-GBD was 0.0 ± 0.3% and 0.0 ± 0.6%, respectively. The maximum variations were 1.2% and 2.3%, respectively. The plans with the variation over 1% shows the reference points were located away from the central axis with/without physical wedge. Conclusion: The confidence limit (2SD) using the Model-GBD and the All-GBD was within 0.6% and 1.2%, respectively. Thus, the use of golden beam data may be feasible for independent verification. In addition to it, the verification using golden beam data provide quality assurance of planning from the view of audit. This research is partially supported by Japan Agency for Medical Research and Development(AMED)

60 APPLIED LIFE SCIENCES↗