At least 1,585 records · Page 88

Measurement Of The Neutron Spectrum Of A DD Electronic Neutron Generator

A Cuttler-Shalev (C-S){sup 3}He proportional counter has been used to measure the energy spectrum of neutrons from a portable deuterium-deuterium electronic neutron generator. To improve the analysis of results from the C-S detector digital pulse shape analysis techniques have been used to eliminate neutron recoil artifacts in the recorded data. Data was collected using a 8-GHz, 10-bit waveform digitizer with its full scale corresponding to approximately 6-MeV neutrons. The measurements were made with the detector axis perpendicular to the direction of ions in the ENG in a plane 0.5-m to the side of the ENG, measuring neutrons emitted at an angle from 87.3 deg. to 92.7 deg. with respect to the path of ions in the ENG. The system demonstrated an energy resolution of approximately 0.040 MeV for the thermal peak and approximately 0.13 MeV at the DD neutron energy. In order to achieve the ultimate resolution capable with this type of detector it is clear that a higher-precision digitizer will be needed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance Characteristics Of An Intensity Modulated Advanced X-Ray Source (IMAXS) For Homeland Security Applications

X-ray cargo inspection systems for the detection and verification of threats and contraband must address stringent, competitive performance requirements. High x-ray intensity is needed to penetrate dense cargo, while low intensity is desirable to minimize the radiation footprint, i.e. the size of the controlled area, required shielding and the dose to personnel. In a collaborative effort between HESCO/PTSE Inc., XScell Corp., Stangenes Industries, Inc. and Rapiscan Laboratories, Inc., an Intensity Modulated Advanced X-ray Source (IMAXS) was designed and produced. Cargo inspection systems utilizing such a source have been projected to achieve up to 2 inches steel-equivalent greater penetration capability, while on average producing the same or smaller radiation footprint as present fixed-intensity sources. Alternatively, the design can be used to obtain the same penetration capability as with conventional sources, but reducing the radiation footprint by about a factor of three. The key idea is to anticipate the needed intensity for each x-ray pulse by evaluating signal strength in the cargo inspection system detector array for the previous pulse. The IMAXS is therefore capable of changing intensity from one pulse to the next by an electronic signal provided by electronics inside the cargo inspection system detector array, which determine the required source intensity for the next pulse. We report on the completion of a 9 MV S-band (2998 MHz) IMAXS source and comment on its performance.

07 ISOTOPE AND RADIATION SOURCES↗

Following Dynamic Processes by X-ray Tomographic Microscopy with Sub-second Temporal Resolution

Several non-destructive imaging techniques offer the possibility to observe rapid phenomena in real time, yet most of these techniques fail when it comes to bulky samples and micrometer precision in three dimensions. Therefore there is clearly a need to develop approaches that address such conditions. We identified the large potential that lies in synchrotron-based x-rays as a probe and developed a direct-space tomographic instrument suitable to provide sub-second temporal resolution with several-micrometers spatial resolution. Selected applications from the field of biology and material science are shown in order to demonstrate the unique capabilities in generating three-dimensional images with very high quality making image segmentation and analysis possible for samples that could, until now, only be studied in two dimensions due to the occurrence of rapid structural changes.

07 ISOTOPE AND RADIATION SOURCES↗

Perspectives on Gamma-Ray Pulsar Emission

Pulsars are powerful sources of radiation across the electromagnetic spectrum. This paper highlights some theoretical insights into non-thermal, magnetospheric pulsar gamma-ray radiation. These advances have been driven by NASA's Fermi mission, launched in mid-2008. The Large Area Telescope (LAT) instrument on Fermi has afforded the discrimination between polar cap and slot gap/outer gap acceleration zones in young and middle-aged pulsars. Altitude discernment using the highest energy pulsar photons will be addressed, as will spectroscopic interpretation of the primary radiation mechanism in the LAT band, connecting to both polar cap/slot gap and outer gap scenarios. Focuses will mostly be on curvature radiation and magnetic pair creation, including population trends that may afford probes of the magnetospheric accelerating potential.

79 ASTRONOMY AND ASTROPHYSICS↗

eA Pion Production at CLAS Aimed at Neutrinos

Preliminary results on semi-inclusive charged pion production in eA collisions at E{sub beam} = 5 GeV/c{sup 2} are presented. The data were collected using the CLAS detector, which is a multipurpose, large acceptance, magnetic spectrometer located in Hall B at the Thomas Jefferson National Accelerator Facility. Distributions in W, Q{sup 2}, p{sub {pi}}, and {theta}{sub {pi}} are shown for data produced using deuterium and carbon targets. Preliminary comparisons with data simulated using the GENIE generator are made. The motivation for this work is to provide distributions useful for tuning the hadronic production models used in extracting results from current and next-generation neutrino oscillation experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Deceleration, precooling, and multi-pass stopping of highly charged ions in Be{sup +} Coulomb crystals

Preparing highly charged ions (HCIs) in a cold and strongly localized state is of particular interest for frequency metrology and tests of possible spatial and temporal variations of the fine structure constant. Our versatile preparation technique is based on the generic modular combination of a pulsed ion source with a cryogenic linear Paul trap. Both instruments are connected by a compact beamline with deceleration and precooling properties. We present its design and commissioning experiments regarding these two functionalities. A pulsed buncher tube allows for the deceleration and longitudinal phase-space compression of the ion pulses. External injection of slow HCIs, specifically Ar{sup 13+}, into the linear Paul trap and their subsequent retrapping in the absence of sympathetic cooling is demonstrated. The latter proved to be a necessary prerequisite for the multi-pass stopping of HCIs in continuously laser-cooled Be{sup +} Coulomb crystals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a strip-shaped X-ray mapping system for 9-cell superconducting cavities

Electrons emitted via field emission during superconducting (SC) radio-frequency (RF) cavity tests at vertical test stands often collide with the iris region inside the cavity, generating X-rays at these locations. In 1.3 GHz 9-cell SC RF cavities designed for the International Linear Collider (ILC), stiffener rings located outside the iris region between cells can interfere with X-ray detection, complicating the precise identification of field emission sites. Hence, in this study, we developed a high-density strip X-ray mapping systems (sX-map) that can be inserted into the iris region of ILC-type 9-cell SC RF cavities. This sX-map facilitates efficient and accurate detection of X-rays generated near the irises, unaffected by the presence of stiffener rings. The sX-map consisted of 32 sensors per strip, with sensors spaced approximately 10 mm apart. It was deployed in every iris of the 9-cell cavity, using a total of 320 sensors. A multiplexer was employed to facilitate the readout of a large number of detectors using a minimal number of signal lines, connecting the strips inside within the vertical test cryostat. In a vertical test conducted at Jefferson Lab (JLab), we demonstrated the capability of sX-map to detect X-rays despite the presence of a stiffener ring. This paper presents the detailed design of the sX-map and the results from the vertical test at JLab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, development and commissioning of a multi-alkali semiconductor photocathode deposition system for the IUAC Delhi light source photoinjector

A fourth-generation light source, called Delhi Light Source (DLS) based on photocathode-based RF gun has been commissioned at Inter-University Accelerator Centre, New Delhi. Presently, the electron beam is being generated from copper photocathode and the beam is being used for scheduled experiments. Soon, the semiconductor photocathode will be used to produce higher beam current. Here, to develop the semiconductor photocathode, a dedicated photocathode deposition facility was developed in collaboration with Brookhaven national Laboratory (BNL) and has been successfully commissioned and becomes operational at IUAC. This deposition facility is an integrated system with the electron gun and is a unique system as it is capable of producing, preserving (without residual gas poisoning) and in-vacuum transfer of the deposited photocathodes from the deposition chamber up to the RF electron gun. The system is designed to operate under ultra-high vacuum (UHV) and is equipped with load-lock chambers, substrate heating assembly, thickness monitoring via a quartz crystal microbalance (QCM), and an in-situ setup for quantum efficiency (QE) measurements. After testing of all the subsystems and a detailed calibration, the first deposition of a cesium telluride (Cs 2 Te) photocathode was successfully performed on a copper (Cu) substrate. This successful commissioning and initial deposition mark a significant step toward the indigenous photocathode development and lays the groundwork for further research into advanced photo emissive materials at IUAC. This paper will discuss the salient features, installation, commissioning, first semiconductor photocathode deposition and its results.

47 OTHER INSTRUMENTATION↗

Higgs boson hadronic branching ratios at the ILC

We present a study of the Higgs boson decay branching ratios to bb, cc, and gluons, one of the cornerstones of the physics program at the International Linear Collider. A standard model Higgs boson of 120 GeV mass, produced in the Higgs-strahlung process at {radical}(s)=250 GeV, was investigated using the full detector simulation and reconstruction procedures. The analysis was performed in the framework of the Silicon Detector concept with full account of inclusive standard model backgrounds. The selected decay modes contained two heavy flavor jets in the final state and required excellent flavor tagging through precise reconstruction of interaction and decay vertices in the detector. A new signal discrimination technique using correlations of neural network outputs was used to determine the branching ratios and estimate their uncertainties, 4.8%, 8.4%, and 12.2% for bb, cc, and gluons, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Kinematical correlations of dielectrons from semileptonic decays of heavy mesons and Drell-Yan processes at BNL RHIC

We discuss kinematical correlations between charged leptons from semileptonic decays of open charm/bottom leptons produced in the Drell-Yan mechanism as well as some other mechanisms not included so far in the literature in proton-proton scattering at Brookhaven National Laboratory (BNL) Relativistic Heavy Ion Collider (RHIC). The distributions of charm and bottom quarks/antiquarks are calculated in the framework of the k{sub t}-factorization approach. For this calculation we use different unintegrated parton distributions from the literature. The hadronization of heavy quarks is done with the help of well-known fragmentation functions. Uncertainties of our predictions related to heavy quark masses, factorization, and renormalization scales as well as due to the choice of fragmentation model are also discussed. We use semileptonic decay functions found by fitting recent semileptonic data obtained by the CLEO and BABAR collaborations. The Drell-Yan processes were calculated including transverse momenta of quarks and antiquarks, using the Kwiecinski parton distributions. We have also taken into consideration reactions initiated by purely QED {gamma}{sup *{gamma}*} fusion in elastic and inelastic pp collisions as well as a recently proposed diffractive mechanism of exclusive charm-anticharm production. The contribution of the latter mechanism is rather small. We get a good description of the dilepton invariant mass spectrum measured recently by the PHENIX Collaboration and present predictions for the dilepton pair transverse momentum distribution as well as the distribution in the azimuthal angle between electron and positron.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cryptotomography: Reconstructing 3D Fourier Intensities from Randomly Oriented Single-Shot Diffraction Patterns

We reconstructed the 3D Fourier intensity distribution of monodisperse prolate nanoparticles using single-shot 2D coherent diffraction patterns collected at DESY's FLASH facility when a bright, coherent, ultrafast x-ray pulse intercepted individual particles of random, unmeasured orientations. This first experimental demonstration of cryptotomography extended the expansion-maximization-compression framework to accommodate unmeasured fluctuations in photon fluence and loss of data due to saturation or background scatter. This work is an important step towards realizing single-shot diffraction imaging of single biomolecules.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Emission Spectroscopy of the 4X Source Discharge With and Without N 2 Gas

This tech note summarizes the December, 1988 emission spectroscopy measurements made on the 4X source discharge with and without N₂ gas added to the H + Cs discharge. This study is motivated by the desire to understand why small amounts of N₂ gas added to the source discharge results in a reduction in the H⁻ beam noise. The beneficial effect of N₂ gas on H⁻ beam noise was first discovered by Bill Ingalls and Stu Orbesen on the ATS SAS source. For the 4X source the observed effect is that when N2 gas is added to the discharge the H⁻ beam noise is reduced about a factor of 2.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Target Window Reliability

The target window design implemented and tested in experiments at ANL have performed without failure for the available beam of 6 mm FWHM on a 12 mm diameter target. However, scaling that design to a 25 mm diameter target size for a 12 mm FWHM beam has proven problematic. Combined thermal and mechanical (pressure induced) stresses and strains are too high to maintain the small coolant gaps and provide adequate fatigue lifetime.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Target Housing Material Options

With gas cooling, heat transfer coefficients are low compared to water. The benefit of gas from a heat transfer point of view is that there is really no upper temperature limit for the coolant, as compared to water, which is limited ultimately by the critical point, and in practice the critical heat flux. In our case with parallel flow channels, water is limited to even lower operating limits by nucleate boiling. So gas can get as hot as the containment material will allow, but to get the density and heat transfer up to something reasonable, we must also increase pressure, thus increasing stress on the containment, namely the front and back faces. We are designing to ASME BPVC, which, for most materials allows a maximum stress of UTS/3. So we want the highest possible UTS. For reference, the front face stress in the 12 mm target at 300 psi was about 90 MPa. The inconel 718 allowable stress at 900°C is 1/3 of 517 or 172 MPa. So we are in a very safe place, but the uTS is dropping rapidly with temperature above 900°C. As we increase target diameter, the challenge will be to keep the stress down. We are probably looking at keeping the allowable at or above the present value, and at as high a temperature as possible.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FOCAL Campaign II/III: Applying Active Hull Controls Using Tuned-mass Dampers/Hull Flexibility and Internal Loads

Campaign II and III of the Floating Offshore-wind Controls Advanced Laboratory Experimental Program (FOCAL) aimed to generate a dataset enabling the validation of the performance and loads of a scaled hull, with and without structural hull control. The floating platform was subjected to a variety of wave environments and controlled using tuned-mass dampers (TMDs) tuned to two of the systems natural frequencies (Platform Pitch and Tower-bending). The floating platform is fully instrumented to record a variety of parameters in real time such as platform dynamics, accelerations, and loads at different points in the structure. The test data considered was generated at the University of Maine's Harold Alfond Wind and Wave (W2) testing facility. This testing was focused only on validation of wave loading, and wind conditions were not considered. As such the platform does not support a working turbine, and instead supports a structure designed to have the same mass properties as the 1:70 IEA 15MW Reference turbine. The Load Cases (LC) considered in this testing campaign are as follows: LC 1.X - Platform Static Offset (TMD off); LC 2.X - Platform Free-decays (TMD off); LC 3.X - Wave Cases (Regular Wave, Irregular Wave, Pink Noise Wave) with and without TMDs active. Detailed properties on the model system are found in the following reference: Lenfest E., Floating Offshore-wind Controls Advanced Laboratory (FOCAL) Experimental Program - Campaigns 2 and 3: 1:70 Model-scale Testing of the IEA-Wind 15MW Reference Turbine and the VolturnUS-S Hull. UMaine ASCC Report Number 23-56-1183.

17 WIND ENERGY↗