Search NASA⌕ Search

SEARCH · Search NASA

Results for “Approach”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

A new approach to semi-inclusive deep-inelastic scattering with QED and QCD factorization

We present the details of a new factorized approach to semi-inclusive deep-inelastic scattering which treats QED and QCD radiation on equal footing, and provides a systematically improvable approximation to the extraction of transverse momentum dependent parton distributions. We demonstrate how the QED contributions can be well approximated by collinear factorization, and illustrate the application of the factorized approach to QED radiation in inclusive scattering. For semi-inclusive processes, we show how radiation effects prevent a well-defined “photon-nucleon” frame, forcing one to use a two-step process to account for the radiation. We illustrate the utility of the new method by explicit application to the spin-dependent Sivers and Collins asymmetries.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A nonparametric approach to modeling dependence among production parameters for energy cost estimation

Dependence existing among production parameters can significantly affect energy costs. For material removal processes, processing times and material amounts to be cut have positive dependence, and the dependence can affect energy costs by varying a peak electricity load. Existing methods to model the dependence of production parameters are based on parametric approaches that cannot accurately represent the dependence due to the rigid nature of parametric models. To address this issue, this study proposes a method to quantify dependence among manufacturing parameters through the application of the empirical copula to the dependence between the milling processing time and the amount of volume to be cut. The proposed method is illustrated by a case study of a manufacturing facility consisting of milling machines; a total of 27 scenarios are simulated for energy cost estimations. The case study clearly shows that the proposed method can capture the dependence between the milling parameters more accurately than a conventional dependence measure from parametric correlation models. Furthermore, the findings from this study would be useful to estimate energy costs in that the proposed method provides a better fit to real production data than conventional parametric approaches can.

42 ENGINEERING↗

A combination interferometric and morphological image processing approach to rapid quality assessment of additively manufactured cellular truss core components

Advanced manufacturing (AM) processes such as laser powder bed fusion (LPBF) are increasingly capable of fabricating components with useful and unprecedented mechanical properties by incorporating complex internal bracing structures. From the standpoint of quality control and assessment, however, internally complex assemblies present significant build-verification challenges. Here we propose a hybrid approach to the inspection involving the application of computer-aided speckle interferometry (CASI) and morphological image processing as a rapid, inexpensive, and facile method for AM quality control. The described methodology has low capital equipment costs, is full-field and non-contact, can be used in an industrial setting, and has very low requirements in terms of operator training and expertise. Consisting primarily of the combination of image processing software with a simple optical system of variable sensitivity, the method is shown to be effective for inspection of a titanium honeycomb component subjected to differential pressure. Results are compared to those achieved with computed tomography (CT), immersion ultrasound testing (UT), and optical holographic interferometry. Here we propose several possible processing strategies for automated quality assessment based on this powerful hybrid approach.

36 MATERIALS SCIENCE↗

Interval Biliary Stent Placement Via Percutaneous Ultrasound Guided Cholecystostomy: Another Approach to Palliative Treatment in Malignant Biliary Tract Obstruction

Percutaneous cholecystostomy is a minimally invasive procedure for providing gallbladder decompression, often in critically ill patients. It can be used in malignant biliary obstruction following failed endoscopic retrograde cholangiopancreatography when the intrahepatic ducts are not dilated or when stent insertion is not possible via the bile ducts. In properly selected patients, percutaneous cholecystostomy in obstructive jaundice is a simple, safe, and rapid option for biliary decompression, thus avoiding the morbidity and mortality involved with percutaneous transhepatic biliary stenting. Subsequent use of a percutaneous cholecystostomy for definitive biliary stent placement is an attractive concept and leaves patients with no external drain. To the best of our knowledge, it has only been described on three previous occasions in the published literature, on each occasion forced by surgical or technical considerations. Traditionally, anatomic/technical considerations and the risk of bile leak have precluded such an approach, but improvements in catheter design and manufacture may now make it more feasible. We report a case of successful interval metal stent placement via percutaneous cholecystostomy which was preplanned and achieved excellent palliation for the patient. The pros and cons of the procedure and approach are discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transradial Approach for Transcatheter Selective Superior Mesenteric Artery Urokinase Infusion Therapy in Patients with Acute Extensive Portal and Superior Mesenteric Vein Thrombosis

The purpose of this investigation was to assess the feasibility and effectiveness of transradial approach for transcatheter superior mesenteric artery (SMA) urokinase infusion therapy in patients with acute extensive portal and superior mesenteric venous thrombosis. During a period of 7 years, 16 patients with acute extensive thrombosis of the portal (PV) and superior mesenteric veins (SMV) were treated by transcatheter selective SMA urokinase infusion therapy by way of the radial artery. The mean age of the patients was 39.5 years. Through the radial sheath, a 5F Cobra catheter was inserted into the SMA, and continuous infusion of urokinase was performed for 5-11 days (7.1 {+-} 2.5 days). Adequate anticoagulation was given during treatment, throughout hospitalization, and after discharge. Technical success was achieved in all 16 patients. Substantial clinical improvement was seen in these 16 patients after the procedure. Minor complications at the radial puncture site were observed in 5 patients, but trans-SMA infusion therapy was not interrupted. Follow-up computed tomography scan before discharge demonstrated nearly complete disappearance of PV-SMV thrombosis in 9 patients and partial recanalization of PV-SMV thrombosis in 7 patients. The 16 patients were discharged 9-19 days (12 {+-} 6.0 days) after admission. Mean duration of follow-up after hospital discharge was 44 {+-} 18.5 months, and no recurrent episodes of PV-SMV thrombosis developed during that time period. Transradial approach for transcatheter selective SMA urokinase infusion therapy in addition to anticoagulation is a safe and effective therapy for the management of patients with acute extensive PV-SMV thrombosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility and Safety of Vascular Closure Devices in an Antegrade Approach to Either the Common Femoral Artery or the Superficial Femoral Artery

Introduction: The purpose of the present study was to analyze complications following antegrade puncture of the common femoral artery (CFA) and the superficial femoral artery (SFA) using vascular closure systems (VCS). Methods: A single-center, retrospective study was performed after obtaining approval from the institutional review board and informed consent from all patients. At our center, the CFA or SFA are used for arterial access. All patients were evaluated clinically on the same day. If there was any suspicion of an access site problem, Duplex ultrasound was performed. Results: Access location was the CFA in 50 patients and the SFA in 130 patients. The sheath size ranged from 4F to 10F. Two patients had to be excluded because of lack of follow-up. Successful hemostasis was achieved in 162 of 178 cases (91 %). The following complications were observed in 16 patients (8.9 %): 4 pseudoaneurysms (2.2 %), 11 hematomas (6.2 %), and 1 vascular occlusion (0.5 %). The two pseudoaneurysms healed spontaneously, in one case an ultrasound-guided thrombin injection was performed, and one aneurysm was compressed manually. No further medical therapy was needed for the hematomas. The one vascular occlusion was treated immediately with angioplasty using a contralateral approach. No significant difference was noted between the CFA and the SFA group with respect to complications (p = 1.000). Conclusions: The use of closure devices for an antegrade approach up to 10F is feasible and safe. No differences in low complication rates were observed between CFA and SFA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transretroperitoneal CT-guided Embolization of Growing Internal Iliac Artery Aneurysm after Repair of Abdominal Aortic Aneurysm: A Transretroperitoneal Approach with Intramuscular Lidocaine Injection Technique

This study was designed to evaluate the efficacy and safety of CT-guided embolization of internal iliac artery aneurysm (IIAA) after repair of abdominal aortic aneurysm by transretroperitoneal approach using the lidocaine injection technique to iliacus muscle, making window for safe needle path for three patients for whom CT-guided embolization of IIAA was performed by transretroperitoneal approach with intramuscular lidocaine injection technique. Transretroperitoneal access to the IIAA was successful in all three patients. In all three patients, the IIAA was first embolized using microcoils. The aneurysmal sac was then embolized with glue and coils without complication. With a mean follow-up of 7 months, the volume of the IIAAs remained stable without residual endoleaks. Transretroperitoneal CT-guided embolization of IIAA using intramuscular lidocaine injection technique is effective, safe, and results in good outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hybrid Approach for Biliary Interventions Employing MRI-Guided Bile Duct Puncture with Near-Real-Time Imaging

ObjectiveTo assess the feasibility of a hybrid approach employing MRI-guided bile duct (BD) puncture for subsequent fluoroscopy-guided biliary interventions in patients with non-dilated (≤3 mm) or dilated BD (≥3 mm) but unfavorable conditions for ultrasonography (US)-guided BD puncture.MethodsA total of 23 hybrid interventions were performed in 21 patients. Visualization of BD and puncture needles (PN) in the interventional MR images was rated on a 5-point Likert scale by two radiologists. Technical success, planning time, BD puncture time and positioning adjustments of the PN as well as technical success of the biliary intervention and complication rate were recorded.ResultsVisualization even of third-order non-dilated BD and PN was rated excellent by both radiologists with good to excellent interrater agreement. MRI-guided BD puncture was successful in all cases. Planning and BD puncture times were 1:36 ± 2.13 (0:16–11:07) min. and 3:58 ± 2:35 (1:11–9:32) min. Positioning adjustments of the PN was necessary in two patients. Repeated capsular puncture was not necessary in any case. All biliary interventions were completed successfully without major complications.ConclusionA hybrid approach which employs MRI-guided BD puncture for subsequent fluoroscopy-guided biliary intervention is feasible in clinical routine and yields high technical success in patients with non-dilated BD and/or unfavorable conditions for US-guided puncture. Excellent visualization of BD and PN in near-real-time interventional MRI allows successful cannulation of the BD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Re-examination of the In Situ Stress Measurements on the 240 Level of the AECL’s URL Using Tensor-Based Approaches

In situ stress is an important parameter in rock mechanics and often displays significant variability in fractured rock masses. Therefore, rigorous statistical approaches for stress variability characterisation are essential components and prerequisites for adequate interpretation of stress measurements. However, currently in rock mechanics, stresses are customarily processed by analysing the principal stress magnitude and orientation separately. As previous works show, these customary scalar/vector approaches violate the tensorial nature of stress and may yield erroneous results.

42 ENGINEERING↗

Particle tracking approach for transport in three-dimensional discrete fracture networks: Particle tracking in 3-D DFNs

The discrete fracture network (DFN) model is a method to mimic discrete pathways for fluid flow through a fractured low-permeable rock mass, and may be combined with particle tracking simulations to address solute transport. However, experience has shown that it is challenging to obtain accurate transport results in three-dimensional DFNs because of the high computational burden and difficulty in constructing a high-quality unstructured computational mesh on simulated fractures. We present a new particle tracking capability, which is adapted to control volume (Voronoi polygons) flow solutions on unstructured grids (Delaunay triangulations) on three-dimensional DFNs. The locally mass-conserving finite-volume approach eliminates mass balance-related problems during particle tracking. The scalar fluxes calculated for each control volume face by the flow solver are used to reconstruct a Darcy velocity at each control volume centroid. The groundwater velocities can then be continuously interpolated to any point in the domain of interest. The control volumes at fracture intersections are split into four pieces, and the velocity is reconstructed independently on each piece, which results in multiple groundwater velocities at the intersection, one for each fracture on each side of the intersection line. This technique enables detailed particle transport representation through a complex DFN structure. Verified for small DFNs, the new simulation capability enables numerical experiments on advective transport in large DFNs to be performed. As a result, we demonstrate this particle transport approach on a DFN model using parameters similar to those of crystalline rock at a proposed geologic repository for spent nuclear fuel in Forsmark, Sweden.

58 GEOSCIENCES↗

Solving Stochastic Dynamic Programming Problems: A Mixed Complementarity Approach

We detail a mixed complementarity problem (MCP) formulation of continuous state dynamic programming problems (DP-MCP). We write the solution to projection methods in value function iteration (VFI) as a joint set of optimality conditions that characterize maximization of the Bellman equation; and approximation of the value function. The MCP approach replaces the iterative component of projection based VFI with a one-shot solution to a square system of complementary conditions. We provide three numerical examples to illustrate our approach.

97 MATHEMATICS AND COMPUTING↗

Sandia fracture challenge 2: Sandia California's modeling approach

The second Sandia Fracture Challenge illustrates that predicting the ductile fracture of Ti-6Al-4V subjected to moderate and elevated rates of loading requires thermomechanical coupling, elasto-thermo-poro-viscoplastic constitutive models with the physics of anisotropy and regularized numerical methods for crack initiation and propagation. We detail our initial approach with an emphasis on iterative calibration and systematically increasing complexity to accommodate anisotropy in the context of an isotropic material model. Blind predictions illustrate strengths and weaknesses of our initial approach. We then revisit our findings to illustrate the importance of including anisotropy in the failure process. Furthermore, mesh-independent solutions of continuum damage models having both isotropic and anisotropic yields surfaces are obtained through nonlocality and localization elements.

36 MATERIALS SCIENCE↗

Droplet Evaporation-Based Approach for Microliter Fuel Property Measurements

Small-volume, high-throughput screening techniques are sought to enable downselection from a large candidate pool of bio-blendstocks to a select few, having physical properties consistent with requirements of downsized, turbo-boosted internal combustion engines. Herein, this work presents a droplet evaporation-based approach to predict heat of vaporization, vapor pressure, diffusion coefficient, and Lennard–Jones parameters for an unknown fuel. Two different schemes, considering the isothermal evaporation of a moving droplet in ambient air, are proposed, which combine droplet velocity and temperature measurements, with some known properties to predict unknown properties. The schemes utilize an inverse solution of a transient model of droplet evaporation solved in an iterative fashion. A baseline scheme, which only requires droplet size change measurements, is evaluated using test data for three liquid fuels, comprising of alkanes and alcohols, as obtained in a temperature-controlled chamber. Results yield temperature-dependent heat of vaporization and vapor pressure predictions within 10 % and 22 %, respectively, of reference values. The advanced scheme, which additionally requires droplet temperature measurement, is numerically evaluated in the current work and will be experimentally validated in future efforts. The advanced scheme is found to significantly improve prediction quality, with deviations less than 2 % and 1 % for heat of vaporization and vapor pressure, while also predicting diffusion coefficient and Lennard–Jones parameters within 5 % and 8 %, respectively. The combined set of approaches, which primarily track droplet evaporation, can be incorporated into a small-volume, high-throughput fuel screening process.

09 BIOMASS FUELS↗

An Alternative Approach to the Extended Drude Model

The original Drude model, proposed over a hundred years ago, is still used today for the analysis of optical properties of solids. Within this model, both the plasma frequency and quasiparticle scattering rate are constant, which makes the model rather inflexible. In order to circumvent this problem, the so-called extended Drude model was proposed, which allowed for the frequency dependence of both the quasiparticle scattering rate and the effective mass. In this work we will explore an alternative approach to the extended Drude model. Here, one also assumes that the quasiparticle scattering rate is frequency dependent; however, instead of the effective mass, the plasma frequency becomes frequency-dependent. This alternative model is applied to the high T{sub c} superconductor Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8+δ} (Bi2212) with T{sub c} = 92 K, and the results are compared and contrasted with the ones obtained from the conventional extended Drude model. The results point to several advantages of this alternative approach to the extended Drude model.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Review of computational approaches to predict the thermodynamic stability of inorganic solids

Improvements in the efficiency and availability of quantum chemistry codes, supercomputing centers, and open materials databases have transformed the accessibility of computational materials design approaches. Thermodynamic stability predictions play a central role in the efficacy of these approaches and should be considered carefully. This review covers the fundamentals of calculating thermodynamic stability using first-principles methods. Stability is delineated into two main topics — stability with respect to decomposition into competing phases and stability with respect to phase transition into alternative structures at fixed composition. For each topic, a summary of the state-of-the-art is provided along with a tutorial overview of practical considerations. The application of machine learning to both kinds of stability predictions is also covered. Finally, the limitations of thermodynamic stability predictions are discussed within the context of predicting the synthesizability of materials.

36 MATERIALS SCIENCE↗

Chemical preintercalation synthesis approach for the formation of new layered tungsten oxides

Tungsten oxide, WO 3 ·nH 2 O, is a unique layered oxide material that offers enhanced performance in electrochromic and energy storage applications. Herein, we report the formation of a new, never previously synthesized, Na-containing layered tungsten oxide phase, Na 0.20 WO 3 ·0.81H 2 O, using a chemical preintercalation approach. The structure and composition of this novel phase were investigated via microscopy, spectroscopy, and diffraction methods. Electrochemical cycling of Na 0.20 WO 3 ·0.81H 2 O electrodes revealed initial discharge capacities of 37.43 mAh g -1 , 480.8 mAh g -1 , and 253.2 mAh g -1 in aqueous H 2 SO 4 cells (potential window of - 0.2–0.8 V vs. Ag/AgCl), non-aqueous Li-ion cells (potential window of 0.1–4.0 V vs. Li/Li + ), and non-aqueous Na-ion cells (potential window of 0.1–4.0 V vs. Na/Na + ), respectively. Additionally, a reversible, pressure-induced color change from pale yellow to dark brown/black was observed for the Na 0.20 WO 3 ·0.81H 2 O sample when it was placed under pressures of 1000 psi or higher. Our results demonstrate the viability of chemical preintercalation synthesis approach to produce new oxide phases with interesting functional properties.

36 MATERIALS SCIENCE↗

Highly Selective Detection of Cr{sup 3+} Ion with Colorimetric & Fluorescent Response Via Chemodosimetric Approach in Aqueous Medium

So far, very few numbers of chemosensors for Cr{sup 3+} ion have been reported. However, the main drawback of reported receptors are the lack of selectivity and other trivalent cations such as Fe{sup 3+}, Al{sup 3+} and anions like F{sup −} and {sup −}OAc frequently interfere with such assays. This paper present the synthesis, characterization & sensor studies of Schiff base containing naphthalene moiety which selectively detect Cr{sup 3+} ion by chemodosimetric approach. Using FT-IR, {sup 1}H NMR, {sup 13}C NMR and ESI mass spectroscopic techniques the probe was characterized. This receptor exhibit more selectivity and sensitivity towards Cr{sup 3+} than other divalent and trivalent cations like Mn{sup 2+}, Zn{sup 2+}, Co{sup 2+}, Ni{sup 2+}, Cd{sup 2+}, Cu{sup 2+}, Hg{sup 2+}, Fe{sup 3+}, and Al{sup 3+} ions. After the addition of chromium ion the receptor get change from yellow to colorless in aqueous medium. But no color change was observed on the addition of other metal ions. Using UV-Vis and PL studies, it was confirmed that the selective hydrolysis of imine group of receptor by Cr{sup 3+} ions takes place with high fluorescence enhancement that is corresponding to 1-naphthylamine. Receptor acts as selective chemodosimeter for Cr{sup 3+} ions with 2:1 stoichiometry and micro molar detection limit. This chemodosimetric approach was applied successfully for bio-imaging of HeLa cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗