Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

A Proton-Cyclotron Wave Storm Generated by Unstable Proton Distribution Functions in the Solar Wind

We use audification of 0.092 seconds cadence magnetometer data from the Wind spacecraft to identify waves with amplitudes greater than 0.1 nanoteslas near the ion gyrofrequency (approximately 0.1 hertz) with duration longer than 1 hour during 2008. We present one of the most common types of event for a case study and find it to be a proton-cyclotron wave storm, coinciding with highly radial magnetic field and a suprathermal proton beam close in density to the core distribution itself. Using linear Vlasov analysis, we conclude that the long-duration, large-amplitude waves are generated by the instability of the proton distribution function. The origin of the beam is unknown, but the radial field period is found in the trailing edge of a fast solar wind stream and resembles other events thought to be caused by magnetic field footpoint motion or interchange reconnection between coronal holes and closed field lines in the corona.

instabilities - plasmas↗

A spectral method for halo particle definition in intense mismatched beams

An advanced spectral analysis of a mismatched charged particle beam propagating through a periodic focusing transport lattice is utilized in particle-in-cell (PIC) simulations. It is found that the betatron frequency distribution function of a mismatched space-charge-dominated beam has a bump-on-tail structure attributed to the beam halo particles. Based on this observation, a new spectral method for halo particle definition is proposed that provides the opportunity to carry out a quantitative analysis of halo particle production by a beam mismatch. In addition, it is shown that the spectral analysis of the mismatch relaxation process provides important insights into the emittance growth attributed to the halo formation and the core relaxation processes. Finally, the spectral method is applied to the problem of space-charge transport limits.

43 PARTICLE ACCELERATORS↗

Analysis of {sup 25}Al energy levels observed in the {sup 28}Si(p,{alpha}){sup 25}Al reaction

The level structure of {sup 25}Al has been studied at the ORNL Holifield Radioactive Ion Beam Facility by measuring the angular and energy distributions of {alpha} particles from the {sup 28}Si(p,{alpha}){sup 25}Al reaction. Proton beams ({approx}10 nA) at laboratory energies of 40 and 42 MeV were generated by the 25 MV tandem accelerator and bombarded a natural silicon target (50 {mu}g/cm{sup 2}). Seventeen levels were observed and spins for several were constrained through a distorted-wave Born approximation analysis of the angular distributions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SEYFERT GALAXIES: NUCLEAR RADIO STRUCTURE AND UNIFICATION

A radio study of a carefully selected sample of 20 Seyfert galaxies that are matched in orientation-independent parameters, which are measures of intrinsic active galactic nucleus power and host galaxy properties, is presented to test the predictions of the unified scheme hypothesis. Our sample sources have core flux densities greater than 8 mJy at 5 GHz on arcsec scales due to the feasibility requirements. These simultaneous parsec-scale and kiloparsec-scale radio observations reveal (1) that Seyfert 1 and Seyfert 2 galaxies have an equal tendency to show compact radio structures on milliarcsecond scales, (2) the distributions of parsec-scale and kiloparsec-scale radio luminosities are similar for both Seyfert 1 and Seyfert 2 galaxies, (3) there is no evidence for relativistic beaming in Seyfert galaxies, (4) similar distributions of source spectral indices in spite of the fact that Seyferts show nuclear radio flux density variations, and (5) the distributions of the projected linear size for Seyfert 1 and Seyfert 2 galaxies are not significantly different as would be expected in the unified scheme. The latter could be mainly due to a relatively large spread in the intrinsic sizes. We also find that a starburst alone cannot power these radio sources. Finally, an analysis of the kiloparsec-scale radio properties of the CfA Seyfert galaxy sample shows results consistent with the predictions of the unified scheme.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-778: Use of the 2D MatriXX Detector for Measuring Scanned Ion Beam Parameters

Purpose: The quality assurance (QA) procedure has to check the most relevant beam parameters to ensure the delivery of the correct dose to patients. Film dosimetry, which is commonly used for scanned ion beam QA, does not provide immediate results. The purpose of this work is to answer whether, for scanned ion beam therapy, film dosimetry can be replaced with the 2D MatriXX detector as a real-time tool. Methods: MatriXX, equipped with 32×32 parallel plate ion-chambers, is a commercial device intended for pre-treatment verification of conventional radiation therapy.The MatriXX, placed at the isocenter, and GAFCHROMIC films, positioned on the MatriXX entrance, were exposed to 131.44 MeV proton and 221.45 MeV/u Carbon-ion beams.The OmniPro-I’mRT software, applied for the data taking of MatriXX, gives the possibility of acquiring consecutive snapshots. Using the NI LabVIEW, the data from snapshots were logged as text files for further analysis. Radiochromic films were scanned with EPSON scanner and analyzed using software programs developed in-house for comparative purposes. Results: The field dose uniformity, flatness, beam position and beam width were investigated. The field flatness for the region covering 6×6 cm{sup 2} square field was found to be better than 2%. The relative standard deviations, expected to be constant over 2×2, 4×4 and 6×6 pixels from MatriXX measurement gives a uniformity of 1.5% in good agreement with the film results.The beam center position is determined with a resolution better than 200 µm for Carbon and less than 100 µm for proton beam.The FWHM determination for a beam wider than 10 mm is satisfactory, whilst for smaller beams the determination is uncertain. Conclusion: Precise beam position and fast 2D dose distribution can be determined in real-time using MatriXX detector. The results show that MatriXX is quick and accurate enough to be used in charged-particle therapy QA.

60 APPLIED LIFE SCIENCES↗

Fast BPM data distribution for global orbit feedback using commercial gigabit ethernet technology

In order to correct beam perturbations in RHIC around 10Hz, a new fast data distribution network was required to deliver BPM position data at rates several orders of magnitude above the capability of the existing system. The urgency of the project limited the amount of custom hardware that could be developed, which dictated the use of as much commercially available equipment as possible. The selected architecture uses a custom hardware interface to the existing RHIC BPM electronics together with commercially available Gigabit Ethernet switches to distribute position data to devices located around the collider ring. Using the minimum Ethernet packet size and a field programmable gate array (FPGA) based state machine logic instead of a software based driver, real-time and deterministic data delivery is possible using Ethernet. The method of adapting this protocol for low latency data delivery, bench testing of Ethernet hardware, and the logic to construct Ethernet packets using FPGA hardware will be discussed. A robust communications system using almost all commercial off-the-shelf equipment was developed in under a year which enabled retrofitting of the existing RHIC BPM system to provide 10 KHz data delivery for a global orbit feedback scheme using 72 BPMs. Total latencies from data acquisition at the BPMs to delivery at the controller modules, including very long transmission distances, were kept under 100 {micro}s, which provide very little phase error in correcting the 10 Hz oscillations. Leveraging off of the speed of Gigabit Ethernet and wide availability of Ethernet products enabled this solution to be fully implemented in a much shorter time and at lower cost than if a similar network was developed using a proprietary method.

43 PARTICLE ACCELERATORS↗

Dosimetric uncertainty in prostate cancer proton radiotherapy

Purpose: The authors we evaluate the uncertainty in proton therapy dose distribution for prostate cancer due to organ displacement, varying penumbra width of proton beams, and the amount of rectal gas inside the rectum. Methods and Materials: Proton beam treatment plans were generated for ten prostate patients with a minimum dose of 74.1 cobalt gray equivalent (CGE) to the planning target volume (PTV) while 95% of the PTV received 78 CGE. Two lateral or lateral oblique proton beams were used for each plan. The authors we investigated the uncertainty in dose to the rectal wall (RW) and the bladder wall (BW) due to organ displacement by comparing the dose-volume histograms (DVH) calculated with the original or shifted contours. The variation between DVHs was also evaluated for patients with and without rectal gas in the rectum for five patients who had 16 to 47 cc of visible rectal gas in their planning computed tomography (CT) imaging set. The uncertainty due to the varying penumbra width of the delivered protons for different beam setting options on the proton delivery system was also evaluated. Results: For a 5 mm anterior shift, the relative change in the RW volume receiving 70 CGE dose (V{sub 70}) was 37.9% (5.0% absolute change in 13.2% of a mean V{sub 70}). The relative change in the BW volume receiving 70 CGE dose (V{sub 70}) was 20.9% (4.3% absolute change in 20.6% of a mean V{sub 70}) with a 5 mm inferior shift. A 2 mm penumbra difference in beam setting options on the proton delivery system resulted in the relative variations of 6.1% (0.8% absolute change) and 4.4% (0.9% absolute change) in V{sub 70} of RW and BW, respectively. The data show that the organ displacements produce absolute DVH changes that generally shift the entire isodose line while maintaining the same shape. The overall shape of the DVH curve for each organ is determined by the penumbra and the distance of the target in beam's eye view (BEV) from the block edge. The beam setting option producing a 2 mm sharper penumbra at the isocenter can reduce the magnitude of maximal doses to the RW by 2% compared to the alternate option utilizing the same block margin of 7 mm. The dose to 0.1 cc of the femoral head on the distal side of the lateral-posterior oblique beam is increased by 25 CGE for a patient with 25 cc of rectal gas. Conclusion: Variation in the rectal and bladder wall DVHs due to uncertainty in the position of the organs relative to the location of sharp dose falloff gradients should be accounted for when evaluating treatment plans. The proton beam delivery option producing a sharper penumbra reduces maximal doses to the rectal wall. Lateral-posterior oblique beams should be avoided in patients prone to develop a large amount of rectal gas.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Elastic scattering of {sup 6}Li on {sup 64}Zn at near-barrier energies

Elastic-scattering angular distributions for the {sup 6}Li+{sup 64}Zn system were measured at eight beam energies from below to above the Coulomb barrier, 12.0{<=}E{sub lab}{<=}22.0 MeV. The experimental data were analyzed within the optical model to study the energy dependence of the interaction potential and to obtain total reaction cross sections. The results obtained using several optical model potentials show similar behavior. The energy dependence of the strengths of the real and imaginary potentials suggests the presence of the breakup threshold anomaly. It is shown that the extracted energy dependence of the interaction potential at sub-barrier energies is very sensitive to possible experimental errors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental evaluation of a spatial resampling technique to improve the accuracy of pencil-beam dose calculation in proton therapy

Purpose: In proton therapy, pencil-beam algorithms (PBAs) are the most widely used dose calculation methods. However, the PB calculations that employ one-dimensional density scaling neglect the effects of lateral density heterogeneity on the dose distributions, whereas some particles included in such pencil beams could overextend beyond the interface of the density heterogeneity. We have simplified a pencil-beam redefinition algorithm (PBRA), which was proposed for electron therapy, by a spatial resampling technique toward an application for proton therapy. The purpose of this study is to evaluate the calculation results of the spatial resampling technique in terms of lateral density heterogeneity by comparison with the dose distributions that were measured in heterogeneous slab phantoms. Methods: The pencil beams are characterized for multiple residual-range (i.e., proton energy) bins. To simplify the PBRA, the given pencil beams are resampled on one or two transport planes, in which smaller sub-beams that are parallel to each other are generated. We addressed the problem of lateral density heterogeneity comparing the calculation results to the dose distributions measured at different depths in heterogeneous slab phantoms using a two-dimensional detector. Two heterogeneity slab phantoms, namely, phantoms A and B, were designed for the measurements and calculations. In phantom A, the heterogeneity slab was placed close to the surface. On the other hand, in phantom B, it was placed close to the Bragg peak in the mono-energetic proton beam. Results: In measurements, lateral dose profiles showed a dose reduction and increment in the vicinity of x= 0 mm in both phantoms at depths z= 142 and 161 mm due to lateral particle disequilibrium. In phantom B, these dose reduction/increment effects were higher/lower, respectively, than those in phantom A. This is because a longer distance from the surface to the heterogeneous slab increases the strength of proton scattering. Sub-beams, which were generated from the resampling plane, formed a detouring/overextending path that was different from that of elemental pencil beams. Therefore, when the spatial resampling was implemented at the surface and immediately upstream of the lateral heterogeneity, the calculation could predict these dose reduction/increment effects. Without the resampling procedure, these dose reduction/increment effects could not be predicted in both phantoms owing to the blurring of the pencil beam. We found that the PBA with the spatial resampling technique predicted the dose reduction/increment at the dose profiles in both phantoms when the sampling plane was defined immediately upstream of the heterogeneous slab. Conclusions: We have demonstrated the implementation of a spatial resampling technique for pencil-beam calculation to address the problem of lateral density heterogeneity. While further validation is required for clinical use, this study suggests that the spatial resampling technique can make a significant contribution to proton therapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

A simple model of electron beam initiated dielectric breakdown

A steady state model that describes the internal charge distribution of a planar dielectric sample exposed to a uniform electron beam was developed. The model includes the effects of charge deposition and ionization of the beam, separate trap-modulated mobilities for electrons and holes, electron-hole recombination, and pair production by drifting thermal electrons. If the incident beam current is greater than a certain critical value (which depends on sample thickness as well as other sample properties), the steady state solution is non-physical.

Beers, B. L.↗

Level structure of {sup 164}Dy from the (n, n′γ) reaction

By employing a beam of reactor fast neutrons, gamma-ray spectra and angular distributions of gamma rays with respect to the neutron-beam axis were measured in the reaction {sup 164}Dy(n, n′γ). The scheme of levels and gamma transitions in {sup 164}Dy was composed on the basis of data published earlier and new levels, rotational bands, gamma transitions, and multipole-mixing parameters. It is concluded that the scheme of J = 0–4 levels is complete up to the excitation energy of 1.95 MeV. The commonly accepted rule in constructing K{sub n}{sup π} = 0{sub 2}{sup +} and 1{sub 1}{sup +} rotational bands is found to be violated. The nature of the 2{sup +} level at the energy of 1796.68 keV is discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Back-to-back pair correlation of Majorana neutrinos with transit magnetic moments

The pair production of Majorana neutrinos with transit magnetic moments from the annihilation of charged particles in colliding experiments is discussed using the Pauli interaction, through which the neutral neutrinos with magnetic moments can be probed by the photon. The pair of neutrinos with different flavors are produced due to the transit magnetic moment coupling. We discuss the correlations of flavors in pairs produced back-to-back in the center of the mass frame, where the angular distribution peaks at {theta}={pi}/2 with respect to the beam direction. We demonstrate that the flavor mixing angle can be inferred by measuring the flavor correlation in pairs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A discrete-continuum coupled finite element modelling approach for fibre reinforced concrete

Highlights: • An easy-to-implement but effective meso-scale modelling approach is developed for FRC. • It is capable of simulating and interpreting all main failure mechanisms in FRC. • It is critically validated by experiments with single or multiple random fibres under various loading conditions. • It can be used to optimise key design factors of FRC at meso/material scale by parametric studies. - Abstract: Fibre reinforced concrete (FRC) exhibits complicated failure modes such as fibre breakage, mortar cracking, crushing and spalling, fibre-mortar interfacial debonding, depending on many material properties, geometric dimensions, boundary and loading conditions. Most existing numerical models are unable to reproduce these failure modes that may occur simultaneously or sequentially in a specimen, mainly due to difficulties in generating finite element meshes with a large number of randomly-oriented fibres. Herein we develop a discrete-continuum coupled finite element modelling approach for FRC materials capable of effectively simulating all the major failure modes. The continuum damaged plasticity model is used to simulate damage and fracture behaviour of the mortar, while debonding of fibre-mortar interfaces is modelled by nonlinear cohesive interfacial elements. Unique techniques are devised to generate conforming meshes between fibres and the surrounding mortar so that the randomly-oriented fibres are easily modelled. The modelling approach is validated by simulating single fibre pullout tests with different inclination angles, notched and non-notched direct tensile tests and three-point bending beam tests with randomly-distributed multiple fibres.

36 MATERIALS SCIENCE↗

Combined effect of injected interstitials and He implantation, and cavities inside dislocation loops in high purity Fe-Cr alloys

High purity Fe-Cr alloys with Cr content ranging from 3 to 14 wt% were irradiated by self-ions at 500 °C in dual-beam mode up to 157 displacements per atom (dpa), 17 appm He/dpa. Transmission electron microscopy (TEM) on focused ion beam foils revealed the depth distribution of irradiation induced cavities and dislocation loops. A detailed quantitative analysis of cavity microstructure was performed on Fe14%Cr, while Fe(3, 5, 10, 12)%Cr were analyzed qualitatively. A homogeneous distribution of small cavities were observed up to the damage peak. From surface to the damage peak, cavity number density increased almost linearly. The cavity microstructure changed drastically at and after the damage peak, where the size increased and number density decreased. Most notably, the microstructure consisted of a striking mixture of heterogeneously nucleated cavities inside dislocation loops and freely nucleated cavities in the matrix. Further, the depth-dependent void swelling increased continuously along the damage depth. This contrasts with most ion irradiation results where suppression of void swelling occurs adjacent to the damage peak due the injected interstitial effect. We hypothesize a plausible mechanism of the observed swelling variation based on a combined effect of the injected interstitials and helium implantation near the damage peak by comparing the results with those in pure iron irradiated under same conditions. This synergistic effect may develop cavity microstructures which do not necessarily reflect microstructures expected due to injected interstitial effect and can be easily wrongly interpreted. The depth dependent dislocation loop microstructure was studied qualitatively in Fe14%Cr sample. Up to the damage peak, a complex dense network of dislocations formed due to the interaction/impingement of the dislocation loops. Individually resolvable loops were only observed after the damage peak, where their association with cavities was noted. Furthermore helium also induced heterogeneous cavity nucleation on dislocations constituting a grain boundary and on pre-existing dislocation lines.

36 MATERIALS SCIENCE↗

Energy and system size dependence of {phi} meson production in Cu+Cu and Au+ Au collisions.

We study the beam-energy and system-size dependence of {phi} meson production (using the hadronic decay mode {phi} {yields} K{sup +}K{sup -}) by comparing the new results from Cu+Cu collisions and previously reported Au+Au collisions at {radical}s{sub NN} = 62.4 and 200 GeV measured in the STAR experiment at RHIC. Data presented in this Letter are from mid-rapidity (|y|<0.5) for 0.4 < p{sub T} < 5 GeV/c. At a given beam energy, the transverse momentum distributions for mesons are observed to be similar in yield and shape for Cu+Cu and Au+Au colliding systems with similar average numbers of participating nucleons. The {phi} meson yields in nucleus-nucleus collisions, normalized by the average number of participating nucleons, are found to be enhanced relative to those from p+p collisions. The enhancement for {phi} mesons lies between strange hadrons having net strangeness = 1 (K{sup -} and {bar {Lambda}}) and net strangeness =2 ({Theta}). The enhancement for {phi} mesons is observed to be higher at {radical}s{sub NN} = 200 GeV compared to 62.4 GeV. These observations for the produced {phi}(s{bar s}) mesons clearly suggest that, at these collision energies, the source of enhancement of strange hadrons is related to the formation of a dense partonic medium in high energy nucleus-nucleus collisions and cannot be alone due to canonical suppression of their production in smaller systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗