At least 1,585 records · Page 88

Application of the Langley plot method to the calibration of the solar backscattered ultraviolet instrument on the Nimbus 7 satellite

The concept of the well-known Langley plot technique, used for the calibration of ground-based instruments, has been generalized for application to satellite instruments. In polar regions, near summer solstice, the solar backscattered ultraviolet (SBUV) instrument on the Nimbus 7 satellite samples the same ozone field at widely different solar zenith angles. These measurements are compared to assess the long-term drift in the instrument calibration. Although the technique provides only a relative wavelength-to-wavelength calibration, it can be combined with existing techniques to determine the drift of the instrument at any wavelength. Using this technique, we have generated a 12-year data set of ozone vertical profiles from SBUV with an estimated accuracy of +/- 5% at 1 mbar and +/- 2% at 10 mbar (95% confidence) over 12 years. Since the method is insensitive to true changes in the atmospheric ozone profile, it can also be used to compare the calibrations of similar SBUV instruments launched without temporal overlap.

Bhartia, P. K.↗

Calibration Of Partial-Pressure-Of-Oxygen Sensors

Report and analysis of, and discussion of improvements in, procedure for calibrating partial-pressure-of-oxygen sensors to satisfy Spacelab calibration requirements released. Sensors exhibit fast drift, which results in short calibration period not suitable for Spacelab. By assessing complete process of determining total drift range available, calibration procedure modified to eliminate errors and still satisfy requirements without compromising integrity of system.

Yount, David W.↗

Automatic releveling of calibration stands for wind tunnel force and moment measurement instrumentation

Wind tunnel force and moment measuring instrumentation at NASA LaRC are calibrated by applying NIST certified dead loads, to generate forces and moments in three orthogonal axes, in twenty five percent increments, up to full-load and down to no-load in a nine point continuous procedure, using specially built calibration stands. The measuring instruments deflect upon the application of loads. These deflections must be cancelled to minimize loading interactions. The older calibration stands, integrated with AC induction motors, or DC motors, have provisions for manually releveling the loading point after each load. A newer stand, with integrated DC stepper motors, relevels automatically under software control. It was proposed to extend automation to the old stands. An algorithm to control the unwieldy induction motors to relevel a calibration stand, to within two arcseconds of horizontal direction automatically, was developed. The system developed uses coasting prediction and load adaptation in a general type robust stability control configuration with noncoincidental feedback. Automatic releveling cuts the releveling time to approximately half of the time required to do it manually. The principal constraint for shorter times is the time constant of the angular position feedback transducer.

Perazza, Manuel Rodriguez↗

Nimbus-7 TOMS Version 7 Calibration

This report describes an improved instrument characterization used for the Version 7 processing of the Nimbus-7 Total Ozone Mapping Spectrometer (TOMS) data record. An improved internal calibration technique referred to as spectral discrimination is used to provide long-term calibration precision of +/- 1%/decade in total column ozone amount. A revised wavelength scale results in a day one calibration that agrees with other satellite and ground-based measurements of total ozone, while a wavelength independent adjustment of the initial radiometric calibration constants provides good agreement with surface reflectivity measured by other satellite-borne ultraviolet measurements. The impact of other aspects of the Nimbus-7 TOMS instrument performance are also discussed. The Version 7 data should be used in all future studies involving the Nimbus-7 TOMS measurements of ozone. The data are available through the NASA Goddard Space Flight Center's Distributive Active Archive Center (DAAC).

Wellemeyer, C. G.↗

Inter-Satellite Calibration Linkages for the Visible and Near-Infrared Channels of the Advanced Very High Resolution Radiometer on the NOAA-7, -9, and -11 Spacecraft

The post-launch degradation of the visible (channel 1: 0.58- 068 microns) and near-infrared (channel 2: approx. 0.72 - l.l microns) channels of the Advanced Very High Resolution Radiometer (AVHRR) on the NOAA-7, -9, and -11 Polar-orbiting Operational Environmental Satellites (POES) was estimated using the south-eastern part of the Libyan Desert as a radiometrically stable calibration target. The relative annual degradation rates, in per cent, for the two channels are, respectively: 3.6 and 4.3 (NOAA-7); 5.9 and 3.5 (NOAA-9); and 1.2 and 2.0 (NOAA-11). Using the relative degradation rates thus determined, in conjunction with absolute calibrations based on congruent path aircraft/satellite radiance measurements over White Sands, New Mexico (USA), the variation in time of the absolute gain or slope of the AVHRR on NOAA-9 was evaluated. Inter-satellite calibration linkages were established, using the AVHRR on NOAA-9 as a normalization standard. Formulae for the calculation of calibrated radiances and albedos (AVHRR usage), based on these interlinkages, are given for the three AVHRRs.

NagarajaRao, C. R.↗

Spectral Irradiance Calibration in the Infrared: 1.2-35 micrometer Spectra of Six Standard Stars - Part 4

Five new absolutely calibrated continuous stellar spectra from 1.2 to 35 microns are presented. The spectra were constructed as far as possible from actual observed spectral fragments taken from the ground, the Kuiper Airborne Observatory (KAO), and the IRAS Low Resolution Spectrometer (LRS). These stars (beta Peg, alpha Boo, beta And, beta Gem, and alpha Hya) augment the author's already created complete absolutely calibrated spectrum for alpha Tau. All these spectra have a common calibration pedigree. The wavelength coverage is ideal for calibration of many existing and proposed ground-based, airborne, and satellite sensors.

Cohen, Martin↗

Calibration of NASA Turbulent Air Motion Measurement System

A turbulent air motion measurement system (TAMMS) was integrated onboard the Lockheed 188 Electra airplane (designated NASA 429) based at the Wallops Flight Facility in support of the NASA role in global tropospheric research. The system provides air motion and turbulence measurements from an airborne platform which is capable of sampling tropospheric and planetary boundary-layer conditions. TAMMS consists of a gust probe with free-rotating vanes mounted on a 3.7-m epoxy-graphite composite nose boom, a high-resolution inertial navigation system (INS), and data acquisition system. A variation of the tower flyby method augmented with radar tracking was implemented for the calibration of static pressure position error and air temperature probe. Additional flight calibration maneuvers were performed remote from the tower in homogeneous atmospheric conditions. System hardware and instrumentation are described and the calibration procedures discussed. Calibration and flight results are presented to illustrate the overall ability of the system to determine the three-component ambient wind fields during straight and level flight conditions.

Barrick, John D. W.↗

Spectral Irradiance Calibration in the Infrared: New Composite Spectra, Comparison with Model Atmospheres, and Far-Infrared Extrapolations - Part 7

We present five new absolutely calibrated continuous stellar spectra constructed as far as possible from spectral fragments observed from the ground, the Kuiper Airborne Observatory (KAO), and the IRAS Low Resolution Spectrometer. These stars-alpha Boo, gamma Dra, alpha Cet, gamma Cru, and mu UMa-augment our six, published, absolutely calibrated spectra of K and early-M giants. All spectra have a common calibration pedigree. A revised composite for alpha Boo has been constructed from higher quality spectral fragments than our previously published one. The spectrum of gamma Dra was created in direct response to the needs of instruments aboard the Infrared Space Observatory (ISO); this star's location near the north ecliptic pole renders it highly visible throughout the mission. We compare all our low-resolution composite spectra with Kurucz model atmospheres and find good agreement in shape, with the obvious exception of the SiO fundamental, still lacking in current grids of model atmospheres. The CO fundamental seems slightly too deep in these models, but this could reflect our use of generic models with solar metal abundances rather than models specific to the metallicities of the individual stars. Angular diameters derived from these spectra and models are in excellent agreement with the best observed diameters. The ratio of our adopted Sirius and Vega models is vindicated by spectral observations. We compare IRAS fluxes predicted from our cool stellar spectra with those observed and conclude that, at 12 and 25 microns, flux densities measured by IRAS should be revised downwards by about 4.1% and 5.7%, respectively, for consistency with our absolute calibration. We have provided extrapolated continuum versions of these spectra to 300 microns, in direct support of ISO (PHT and LWS instruments). These spectra are consistent with IRAS flux densities at 60 and 100 microns.

Cohen, Martin↗

Spectral Irradiance Calibration in the Infrared: 1.2 - 35 microns Spectra of Six Standard Stars - Part 4

We present five new absolutely calibrated continuous stellar spectra from 1.2 to 35 microns, constructed as far as possible from actual observed spectral fragments taken from the ground, the Kuiper Airborne Observatory (KAO), and the IRAS Low Resolution Spectrometer (LRS). These stars- beta Peg, alpha Boo, beta And, beta Gem, and alpha Hya-augment our already created complete absolutely calibrated spectrum for alpha Tau. All these spectra have a common calibration pedigree. The wavelength coverage is ideal for calibration of many existing and proposed ground-based, airborne, and satellite sensors.

Cohen, Martin↗

Design and Calibration of the X-33 Flush Airdata Sensing (FADS) System

This paper presents the design of the X-33 Flush Airdata Sensing (FADS) system. The X-33 FADS uses a matrix of pressure orifices on the vehicle nose to estimate airdata parameters. The system is designed with dual-redundant measurement hardware, which produces two independent measurement paths. Airdata parameters that correspond to the measurement path with the minimum fit error are selected as the output values. This method enables a single sensor failure to occur with minimal degrading of the system performance. The paper shows the X-33 FADS architecture, derives the estimating algorithms, and demonstrates a mathematical analysis of the FADS system stability. Preliminary aerodynamic calibrations are also presented here. The calibration parameters, the position error coefficient (epsilon), and flow correction terms for the angle of attack (delta alpha), and angle of sideslip (delta beta) are derived from wind tunnel data. Statistical accuracy of' the calibration is evaluated by comparing the wind tunnel reference conditions to the airdata parameters estimated. This comparison is accomplished by applying the calibrated FADS algorithm to the sensed wind tunnel pressures. When the resulting accuracy estimates are compared to accuracy requirements for the X-33 airdata, the FADS system meets these requirements.

Whitmore, Stephen A.↗

Spectral Irradiance Calibration in the Infrared. 7. 5-14 microns Spectroscopy of the Asteroids Ceres, Vesta, and Pallas

We describe our efforts to seek "closure" in our infrared absolute calibration scheme by comparing spectra of asteroids, absolutely calibrated through reference stars, with "Standard Thermal Models" and "Thermophysical Models" for these bodies. Our use of continuous 5-14 microns airborne spectra provides complete sampling of the rise to, and peak, of the infrared spectral energy distribution and constrains these models. Such models currently support the absolute calibration of ISO-PHOT at far-infrared wave- lengths (as far as 300 microns), and contribute to that of the Mid-Infrared Spectrometer on the "Infrared Telescope in Space" in the 6-12 microns region. The best match to our observed spectra of Ceres and Vesta is a, standard thermal model using a beaming factor of unity. We also report the presence of three emissivity features in Ceres which may complicate the traditional model extrapolation to the far-infrared from contemporaneous ground-based N-band photometry that is used to support calibration of, for example, ISO-PHOT. While identification of specific materials that cause these features is not made, we discuss families of minerals that may be responsible.

Cohen, Martin↗

Calibration of the AXAF Observatory: Overview

The Advanced X-ray Astrophysics Facility (AXAF) will soon begin its exploration of the x-ray universe, providing unprecedented angular and spectral resolution. Also unprecedented is the ambitious goal of calibrating the AXAF observatory to an accuracy of a few percent. Toward this end, AXAF science and engineering teams undertook an extensive calibration program at component, subsystem, and system levels. This paper is an overview of the system-level calibration activities, conducted over the past year at the Marshall Space Flight Center (MSFC) X-Ray Calibration Facility (XRCF).

Weisskopf, M.C.↗

Calibration of the AXAF Observatory: Overview

The Advanced X-ray Astrophysics Facility (AXAF) will soon begin its exploration of the x-ray universe, providing unprecedented angular and spectral resolution. Also unprecedented is the ambitious goal of calibrating the AXAF observatory to an accuracy of a few percent. Toward this end, AXAF science and engineering teams undertook an extensive calibration program at component, subsystem, and system levels. This paper is an overview of the system-level calibration activities, conducted over the past year at the Marshall Space Flight Center (MSFC) X-Ray Calibration Facility (XRCF).

Weisskopf, M. C.↗

Spectral Irradiance Calibration in the Infrared: 5-14 Micron Spectroscopy of the Asteroids Ceres, Vesta, and Pallas - 8

We describe our efforts to seek "closure" in our infrared absolute calibration scheme by comparing spectra of asteroids, absolutely calibrated through reference stars, with "standard thermal models" and "thermophysical models" for these bodies. Our use of continuous 5-14 microns airborne spectra provides complete sampling of the rise to, and peak, of the infrared spectral energy distribution and constrains these models. Such models currently support the absolute calibration of the Infrared Space Observatory Imaging Photopolarimeter (ISOPHOT) at far-infrared wavelengths (as far as 300 microns) and contribute to that of the Mid-Infrared Spectrometer on the Infrared Telescope in Space in the 6 - 12 microns region. The best match to our observed spectra of Ceres and Vesta is a standard thermal model using a beaming factor of unity. We also report the presence of three emissivity features in Ceres that may complicate the traditional model extrapolation to the far-infrared from contemporaneous ground-based N-band photometry that is used to support calibration of, for example, ISOPHOT. While identification of specific materials that cause these features is not made, we discuss families of minerals that may be responsible.

Cohen, Martin↗

On the Use of Monochromators for the Calibration of AXAF

Data acquired, during the AXAF calibration at MSFC's X-Ray Calibration Facility (XRCF), using monochromators requires special analysis owing to potentially large spatial variations in the monochromators' beams and to higher-order contributions to the spectral content. A description of the monochromators -- the Double-Crystal Monochromator (DCM) and the HIgh-Resolution Erect-Field Spectrometer (HIREFS\TM) reflection-grating monochromator --- is given, followed by a discussion of the spectral and spatial content as monitored by Beam-Normalization Detector (BND) flow proportional counters (FPCs). Emphasis is given to the methodology employed in determining the spatial content through fits to Beam Uniformity (BU) measurements made nonsimultaneously, either during calibration or during pre-calibration source characterization. We present an interpolation scheme which adequately represents the beam properties over a wide range of source conditions.

Swartz, Douglas A.↗

Calibration of the AXAF Observatory: Overview

The Advanced X-ray Astrophysics Facility (AXAF) will soon begin its exploration of the X-ray universe, providing unprecedented angular and spectral resolution. Also unprecedented is the ambitious goal of calibrating the AXAF observatory to an accuracy of a few percent. Toward this end, AXAF science and engineering teams undertook an extensive calibration program at component, subsystem, and system levels. This paper is an overview of the system-level calibration activities, conducted over the past year at the Marshall Space Flight Center (MSFC) X-Ray Calibration Facility (XRCF).

Weisskopf, M. C.↗

Numerical Analysis of a Radiant Heat Flux Calibration System

A radiant heat flux gage calibration system exists in the Flight Loads Laboratory at NASA's Dryden Flight Research Center. This calibration system must be well understood if the heat flux gages calibrated in it are to provide useful data during radiant heating ground tests or flight tests of high speed aerospace vehicles. A part of the calibration system characterization process is to develop a numerical model of the flat plate heater element and heat flux gage, which will help identify errors due to convection, heater element erosion, and other factors. A 2-dimensional mathematical model of the gage-plate system has been developed to simulate the combined problem involving convection, radiation and mass loss by chemical reaction. A fourth order finite difference scheme is used to solve the steady state governing equations and determine the temperature distribution in the gage and plate, incident heat flux on the gage face, and flat plate erosion. Initial gage heat flux predictions from the model are found to be within 17% of experimental results.

Jiang, Shanjuan↗

Cepheid Calibration of the Peak Brightness of SNe Ia.: SN 1989B in NGC 3627 - 9

Repeated imaging observations have been made of NGC 3627 with the Hubble Space Telescope in 1997/98, over an interval of 58 days. Images were obtained on 12 epochs in the F555W band and on five epochs in the F8141,V band. The galaxy hosted the prototypical, "Branch normal", type la supernova SN 1989B. A total of 83 variables have been found, of which 68 are definite Cepheid variables with periods ranging from 75 days to 3.85 days. The de-reddened distance modulus is determined to be (m - M)(sub 0) = 30.22 +/- 0.12 (internal uncertainty) using a subset of the Cepheid data whose reddening and error parameters are secure. The photometric data of Wells et al. (1994), combined with the Cepheid data for NGC 3627 give MB(max) = -19.36 +/- 0.18 and M(sub V)(max) = -19.34 +/- 0.16 for SN 1989B. Combined with the previous six calibrations in this program, plus two additional calibrations determined by others gives the mean absolute magnitudes at maximum of (M(sub B)) = -19.48 +/- 0.07 for "Brunch normal" SNe Ia at this interim stage in the calibration program. Using the argument by Wells et al. (1994) that SN 1989B here is virtually identical in decay rate and colors at maximum with SN 198ON in NGC 1316 in the Fornax cluster, and that such identity means nearly identical absolute magnitude, it follows that the difference in the distance modulus of NGC 3627 and NGC 1316 is 1.62 +/- 0.03 mag. Thus the NGC 3627 modulus implies that (m - M)(sub 0) = 31.84 for NGC 1316. The second parameter correlations of M(max) of blue SNe la with decay rate, color at maximum, and Hubble type are re-investigated. The dependence of (M(max)) on decay rate is non-linear, showing a minimum for decay rates between 1.0 less than ADelta(sub m)15 less than 1.6. Magnitudes corrected for decay rate show no dependence on Hubble type, but a dependence on color remains. Correcting both the fiducial sample of 34 SNe la with decay-rate data and the current eight calibrating SNe la for the correlation with decay rate as well as color gives H(sub 0) = 60 +/- 2 (internal) km/s Mpc, in both B and V. The same value to within 4% is obtained if only the SNe la in spirals (without second parameter corrections) are considered. The correlation of SNe la color at maximum with M(max) cannot be due to internal absorption because the slope coefficients in B, V, and I with the change in magnitude are far from or even opposite to the canonical reddening values. The color effect must be intrinsic to the supernova physics. "Absorption" corrections of distant blue SNe la will lead to incorrect values of H(sub 0). The Cepheid distances used in this series are insensitive to metallicity differences. The zeropoint of the P-L relation is based on an assumed LMC modulus of (m - M)(sub 0) = 18.50. As this may have to be increased by 0(sup m).06 to 0(sup m).08, all distances in this paper will follow and Ho will decrease by 3 - 4%.

Saha, A.↗