Search NASA⌕ Search

SEARCH · Search NASA

Results for “Concurrent effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

HPV Genotypes Predict Survival Benefits From Concurrent Chemotherapy and Radiation Therapy in Advanced Squamous Cell Carcinoma of the Cervix

Purpose: To study the prognostic value of human papillomavirus (HPV) genotypes in patients with advanced cervical cancer treated with radiation therapy (RT) alone or concurrent chemoradiation therapy (CCRT). Methods and Materials: Between August 1993 and May 2000, 327 patients with advanced squamous cell carcinoma of the cervix (International Federation of Gynecology and Obstetrics stage III/IVA or stage IIB with positive lymph nodes) were eligible for this study. HPV genotypes were determined using the Easychip Registered-Sign HPV genechip. Outcomes were analyzed using Kaplan-Meier survival analysis and the Cox proportional hazards model. Results: We detected 22 HPV genotypes in 323 (98.8%) patients. The leading 4 types were HPV16, 58, 18, and 33. The 5-year overall and disease-specific survival estimates for the entire cohort were 41.9% and 51.4%, respectively. CCRT improved the 5-year disease-specific survival by an absolute 9.8%, but this was not statistically significant (P=.089). There was a significant improvement in disease-specific survival in the CCRT group for HPV18-positive (60.9% vs 30.4%, P=.019) and HPV58-positive (69.3% vs 48.9%, P=.026) patients compared with the RT alone group. In contrast, the differences in survival with CCRT compared with RT alone in the HPV16-positive and HPV-33 positive subgroups were not statistically significant (P=.86 and P=.53, respectively). An improved disease-specific survival was observed for CCRT treated patients infected with both HPV16 and HPV18, but these differenced also were not statistically significant. Conclusions: The HPV genotype may be a useful predictive factor for the effect of CCRT in patients with advanced squamous cell carcinoma of the cervix. Verifying these results in prospective trials could have an impact on tailoring future treatment based on HPV genotype.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Digital Multicasting of Multiple Audio Streams

The Mission Control Center Voice Over Internet Protocol (MCC VOIP) system (see figure) comprises hardware and software that effect simultaneous, nearly real-time transmission of as many as 14 different audio streams to authorized listeners via the MCC intranet and/or the Internet. The original version of the MCC VOIP system was conceived to enable flight-support personnel located in offices outside a spacecraft mission control center to monitor audio loops within the mission control center. Different versions of the MCC VOIP system could be used for a variety of public and commercial purposes - for example, to enable members of the general public to monitor one or more NASA audio streams through their home computers, to enable air-traffic supervisors to monitor communication between airline pilots and air-traffic controllers in training, and to monitor conferences among brokers in a stock exchange. At the transmitting end, the audio-distribution process begins with feeding the audio signals to analog-to-digital converters. The resulting digital streams are sent through the MCC intranet, using a user datagram protocol (UDP), to a server that converts them to encrypted data packets. The encrypted data packets are then routed to the personal computers of authorized users by use of multicasting techniques. The total data-processing load on the portion of the system upstream of and including the encryption server is the total load imposed by all of the audio streams being encoded, regardless of the number of the listeners or the number of streams being monitored concurrently by the listeners. The personal computer of a user authorized to listen is equipped with special- purpose MCC audio-player software. When the user launches the program, the user is prompted to provide identification and a password. In one of two access- control provisions, the program is hard-coded to validate the user s identity and password against a list maintained on a domain-controller computer at the MCC. In the other access-control provision, the program verifies that the user is authorized to have access to the audio streams. Once both access-control checks are completed, the audio software presents a graphical display that includes audiostream-selection buttons and volume-control sliders. The user can select all or any subset of the available audio streams and can adjust the volume of each stream independently of that of the other streams. The audio-player program spawns a "read" process for the selected stream(s). The spawned process sends, to the router(s), a "multicast-join" request for the selected streams. The router(s) responds to the request by sending the encrypted multicast packets to the spawned process. The spawned process receives the encrypted multicast packets and sends a decryption packet to audio-driver software. As the volume or muting features are changed by the user, interrupts are sent to the spawned process to change the corresponding attributes sent to the audio-driver software. The total latency of this system - that is, the total time from the origination of the audio signals to generation of sound at a listener s computer - lies between four and six seconds.

Macha, Mitchell↗

Teamwork for Oversight of Processes and Systems (TOPS). Implementation guide for TOPS version 2.0, 10 August 1992

As the nation redefines priorities to deal with a rapidly changing world order, both government and industry require new approaches for oversight of management systems, particularly for high technology products. Declining defense budgets will lead to significant reductions in government contract management personnel. Concurrently, defense contractors are reducing administrative and overhead staffing to control costs. These combined pressures require bold approaches for the oversight of management systems. In the Spring of 1991, the DPRO and TRW created a Process Action Team (PAT) to jointly prepare a Performance Based Management (PBM) system titled Teamwork for Oversight of Processes and Systems (TOPS). The primary goal is implementation of a performance based management system based on objective data to review critical TRW processes with an emphasis on continuous improvement. The processes are: Finance and Business Systems, Engineering and Manufacturing Systems, Quality Assurance, and Software Systems. The team established a number of goals: delivery of quality products to contractual terms and conditions; ensure that TRW management systems meet government guidance and good business practices; use of objective data to measure critical processes; elimination of wasteful/duplicative reviews and audits; emphasis on teamwork--all efforts must be perceived to add value by both sides and decisions are made by consensus; and synergy and the creation of a strong working trust between TRW and the DPRO. TOPS permits the adjustment of oversight resources when conditions change or when TRW systems performance indicate either an increase or decrease in surveillance is appropriate. Monthly Contractor Performance Assessments (CPA) are derived from a summary of supporting system level and process-level ratings obtained from objective process-level data. Tiered, objective, data-driven metrics are highly successful in achieving a cooperative and effective method of measuring performance. The teamwork-based culture developed by TOPS proved an unequaled success in removing adversarial relationships and creating an atmosphere of continuous improvement in quality processes at TRW. The new working relationship does not decrease the responsibility or authority of the DPRO to ensure contract compliance and it permits both parties to work more effectively to improve total quality and reduce cost. By emphasizing teamwork in developing a stronger approach to efficient management of the defense industrial base TOPS is a singular success.

Strand, Albert A.↗

Trends in Human Spaceflight: Failure Tolerance, High Reliability and Correlated Failure History

In a half century of human spaceflight, NASA has continuously refined agency safety and reliability requirements in response to mission demands, critical failures, and technology development. Early spacecraft, including Mercury, Gemini and Apollo vehicles, were highly reliant on dissimilar redundancy and demonstrated test margins. Later programs, such as the reusable Space Transportation System (STS) and International Space Station (ISS), introduced probabilistic studies and isolated two-failure tolerance to improve robustness at the expense of added complexity. More recently, the Orion Multi-Program Crew Vehicle (MPCV) program adopted universal single-failure tolerance with two categorical exceptions; Zero-Failure Tolerant (0FT) and Design for Minimum Risk (DFMR) hardware. Failure tolerance variances are defined and managed in accordance with agency human-rating requirements, and require concurrence from program Technical Authorities (TA) as well as the MPCV Safety and Mission Assurance Safety and Engineering Review Panel (MSERP). To understand and reaffirm standards applied to Apollo, Space Shuttle and Orion vehicles, Orion and Deep Space Gateway Safety and Mission Assurance (S&MA) representatives conducted accelerated research to compare unique safety and reliability criteria against ground and flight anomalies, based on information contained in post-mission reports and the Problem Reporting and Corrective Action (PRACA) database. In some cases, high-profile failures and narrow escapes have reinforced decisions to maintain or adapt safety requirements. In others, empirical trends have highlighted the need for vigilance and innovative safety guidelines. Given the inability to achieve absolute compliance with evolving safety and reliability requirements, the team conducted a targeted review of DFMR and 0FT propulsion elements within the framework of changing system design, inspection, materials and process developments to formulate conclusions on technological maturity, failure density, and net changes in safety risk. Based on the aggregate performance of high-reliability and failure-tolerant systems, the authors have attempted to establish best practices and guidelines to inform future program decisions. On a somewhat cautionary note, this study is not intended to direct a universal set of requirements for future missions based on prior lessons learned. Spacecraft safety is a multi-variable problem, and attempts to mitigate past failures will not guarantee future success. However, this assessment offers a retrospective review of policy changes, implementation and effectiveness. In the future, NASA, European Space Agency (ESA) and industry partners may benefit from a more robust correlation between requirements and performance, as space-faring nations work toward more challenging, complex and long-duration commercial and deep-space ventures.

Green, Carrie↗

Optimized FPGA Implementation of Multi-Rate FIR Filters Through Thread Decomposition

Multi-rate finite impulse response (MRFIR) filters are among the essential signal-processing components in spaceborne instruments where finite impulse response filters are often used to minimize nonlinear group delay and finite precision effects. Cascaded (multistage) designs of MRFIR filters are further used for large rate change ratio in order to lower the required throughput, while simultaneously achieving comparable or better performance than single-stage designs. Traditional representation and implementation of MRFIR employ polyphase decomposition of the original filter structure, whose main purpose is to compute only the needed output at the lowest possible sampling rate. In this innovation, an alternative representation and implementation technique called TD-MRFIR (Thread Decomposition MRFIR) is presented. The basic idea is to decompose MRFIR into output computational threads, in contrast to a structural decomposition of the original filter as done in the polyphase decomposition. A naive implementation of a decimation filter consisting of a full FIR followed by a downsampling stage is very inefficient, as most of the computations performed by the FIR state are discarded through downsampling. In fact, only 1/M of the total computations are useful (M being the decimation factor). Polyphase decomposition provides an alternative view of decimation filters, where the downsampling occurs before the FIR stage, and the outputs are viewed as the sum of M sub-filters with length of N/M taps. Although this approach leads to more efficient filter designs, in general the implementation is not straightforward if the numbers of multipliers need to be minimized. In TD-MRFIR, each thread represents an instance of the finite convolution required to produce a single output of the MRFIR. The filter is thus viewed as a finite collection of concurrent threads. Each of the threads completes when a convolution result (filter output value) is computed, and activated when the first input of the convolution becomes available. Thus, the new threads get spawned at exactly the rate of N/M, where N is the total number of taps, and M is the decimation factor. Existing threads retire at the same rate of N/M. The implementation of an MRFIR is thus transformed into a problem to statically schedule the minimum number of multipliers such that all threads can be completed on time. Solving the static scheduling problem is rather straightforward if one examines the Thread Decomposition Diagram, which is a table-like diagram that has rows representing computation threads and columns representing time. The control logic of the MRFIR can be implemented using simple counters. Instead of decomposing MRFIRs into subfilters as suggested by polyphase decomposition, the thread decomposition diagrams transform the problem into a familiar one of static scheduling, which can be easily solved as the input rate is constant.

Kobayashi, Kayla N.↗

From iron(III) precursor to magnetite and vice versa

The syntheses of nanosize magnetite particles by wet-chemical oxidation of Fe{sup 2+} have been extensively investigated. In the present investigation the nanosize magnetite particles were synthesised without using the Fe(II) precursor. This was achieved by {gamma}-irradiation of water-in-oil microemulsion containing only the Fe(III) precursor. The corresponding phase transformations were monitored. Microemulsions (pH {approx} 12.5) were {gamma}-irradiated at a relatively high dose rate of {approx}22 kGy/h. Upon 1 h of {gamma}-irradiation the XRD pattern of the precipitate showed goethite and unidentified low-intensity peaks. Upon 6 h of {gamma}-irradiation, reductive conditions were achieved and substoichiometric magnetite ({approx}Fe{sub 2.71}O{sub 4}) particles with insignificant amount of goethite particles found in the precipitate. Hydrated electrons (e{sub aq}{sup -}), organic radicals and hydrogen gas as radiolytic products were responsible for the reductive dissolution of iron oxide in the microemulsion and the reduction Fe{sup 3+} {yields} Fe{sup 2+}. Upon 18 h of {gamma}-irradiation the precipitate exhibited dual behaviour, it was a more oxidised product than the precipitate obtained after 6 h of {gamma}-irradiation, but it contained magnetite particles in a more reduced form ({approx}Fe{sub 2.93}O{sub 4}). It was presumed that the reduction and oxidation processes existed as concurrent competitive processes in the microemulsion. After 18 h of {gamma}-irradiation the pH of the medium shifted from the alkaline to the acidic range. The high dose rate of {approx}22 kGy/h was directly responsible for this shift to the acidic range. At a slightly acidic pH a further reduction of Fe{sup 3+} {yields} Fe{sup 2+} resulted in the formation of more stoichiometric magnetite particles, whereas the oxidation conditions in the acidic medium permitted the oxidation Fe{sup 2+} {yields} Fe{sup 3+}. The Fe{sup 3+} was much less soluble in the acidic medium and it hydrolysed and recrystallised as goethite. The {gamma}-irradiation of the microemulsion for 25 h at a lower dose rate of 16 kGy/h produced pure substoichiometric nanosize magnetite particles of about 25 nm in size and with the stoichiometry of Fe{sub 2.83}O{sub 4}.

36 MATERIALS SCIENCE↗

Neoadjuvant Sandwich Treatment With Oxaliplatin and Capecitabine Administered Prior to, Concurrently With, and Following Radiation Therapy in Locally Advanced Rectal Cancer: A Prospective Phase 2 Trial

Purpose: Systemic failure remains the major challenge in management of locally advanced rectal cancer (LARC). To optimize the timing of neoadjuvant treatment and enhance systemic control, we initiated a phase 2 trial to evaluate a new strategy of neoadjuvant sandwich treatment, integrating induction chemotherapy, concurrent chemoradiation therapy, and consolidation chemotherapy. Here, we present preliminary results of this trial, reporting the tumor response, toxicities, and surgical complications. Methods and Materials: Fifty-one patients with LARC were enrolled, among which were two patients who were ineligible because of distant metastases before treatment. Patients were treated first with one cycle of induction chemotherapy consisting of oxaliplatin, 130 mg/m² on day 1, with capecitabine, 1000 mg/m² twice daily for 14 days every 3 weeks (the XELOX regimen), followed by chemoradiation therapy, 50 Gy over 5 weeks, with the modified XELOX regimen (oxaliplatin 100 mg/m²), and then with another cycle of consolidation chemotherapy with the XELOX regimen. Surgery was performed 6 to 8 weeks after completion of radiation therapy. Tumor responses, toxicities, and surgical complications were recorded. Results: All but one patent completed the planned schedule of neoadjuvant sandwich treatment. Neither life-threatening blood count decrease nor febrile neutropenia were observed. Forty-five patents underwent optimal surgery with total mesorectal excision (TME). Four patients refused surgery because of clinically complete response. There was no perioperative mortality in this cohort. Five patients (11.1%) developed postoperative complications. Among the 45 patients who underwent TME, pathologic complete response (pCR), pCR or major regression, and at least moderate regression were achieved in 19 (42.2%), 37 (82.2%), and 44 patients (97.8%), respectively. Conclusions: Preliminary results suggest that the strategy of neoadjuvant sandwich treatment using XELOX regimen as induction, concomitant, and consolidation chemotherapy to the conventional radiation is well tolerated. The strategy is highly effective in terms of pCR and major regression, which warrants further investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Changes in Liver Volume Observed Following Sorafenib and Liver Radiation Therapy

Purpose: The purpose of this study was to quantify unexpected liver volume reductions in patients treated with sorafenib prior to and during liver radiation therapy (RT). Methods and Materials: Fifteen patients were treated in a phase 1 study of sorafenib for 1 week, followed by concurrent sorafenib-RT (in 6 fractions). Patients had either focal cancer (treated with stereotactic body RT [SBRT]) or diffuse disease (treated with whole-liver RT). Liver volumes were contoured and recorded at planning (day 0) from the exhale CT. After 1 week of sorafenib (day 8), RT image guidance at each fraction was performed using cone beam CT (CBCT). Planning liver contours were propagated and modified on the reconstructed exhale CBCT. This was repeated in 12 patients treated with SBRT alone without sorafenib. Three subsequent patients (2 sorafenib-RT and 1 non-sorafenib) were also assessed with multiphasic helical breath-hold CTs. Results: Liver volume reductions on CBCT were observed in the 15 sorafenib-RT patients (median decrease of 68 cc, P=.02) between day 0 and 8; greater in the focal (P=.025) versus diffuse (P=.52) cancer stratum. Seven patients (47%) had reductions larger than the 95% intraobserver contouring error. Liver reductions were also observed from multiphasic CTs in the 2 additional sorafenib-RT patients between days 0 and 8 (decreases of 232.5 cc and 331.7 cc, respectively) and not in the non-sorafenib patient (increase of 92 cc). There were no significant changes in liver volume between planning and first RT in 12 patients with focal cancer treated with SBRT alone (median increase, 4.8 cc, P=.86). Conclusions: Liver volume reductions were observed after 7 days of sorafenib, prior to RT, most marked in patients with focal liver tumors, suggesting an effect of sorafenib on normal liver. Careful assessment of potential liver volume changes immediately prior to SBRT may be necessary in patients in sorafenib or other targeted therapies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-Dimensional Conformal Radiotherapy in Prostate Cancer Patients: Rise in Interleukin 6 (IL-6) but not IL-2, IL-4, IL-5, Tumor Necrosis Factor-{alpha}, MIP-1-{alpha}, and LIF Levels

Purpose: To investigate the effect of radiotherapy (RT) on serum levels of interleukin-2 (IL-2), IL-4, IL-5, IL-6, tumor necrosis factor alpha (TNF-{alpha}), macrophage inflammatory protein-1-alpha (MIP-1-{alpha}) and leukemia inhibitory factor (LIF) in patients with prostate cancer. Methods and Materials: Forty eight patients with prostate cancer received three-dimensional conformal blocking radiation therapy with a linear accelerator. IL-2, IL-4, IL-5, IL-6, TNF-{alpha}, MIP-1-{alpha}, and LIF levels were measured by the related immunoassay kit 1 day before the beginning of RT and during RT at days 15 and 30. Results: The mean IL-2 values were elevated before and during the RT in contrast with those of IL-4, IL-5, IL-6, TNF-{alpha}, MIP-1-{alpha}, and LIF, which were within the normal range under the same conditions. Regarding markers IL-2, IL-4, IL-5, TNF-{alpha}, MIP-1-{alpha}, and LIF, comparisons among the three groups (before treatment and 15 and 30 days during RT) did not show significant differences. Although values were within the normal range, there was a significant rise in IL-6 levels at day 15 of RT (p = 0.0049) and a decline at day 30 to levels that were similar to those observed before RT. Conclusions: IL-6 appeared to peak after 15 days of RT before returning to pre-RT levels. In contrast, IL-2, IL-4, IL-5, TNF-{alpha}, MIP-1-{alpha}, and LIF levels were not sensitive to irradiation. The increased levels of IL-6 following RT without the concurrent elevation of other cytokines involved in the acute phase reaction did not suggest a classical inflammatory response to radiation exposure. Further studies should be designed to elucidate the role of IL-6 levels in patients with prostate cancer treated with RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficacy Endpoints of Radiation Therapy Group Protocol 0247: A Randomized, Phase 2 Study of Neoadjuvant Radiation Therapy Plus Concurrent Capecitabine and Irinotecan or Capecitabine and Oxaliplatin for Patients With Locally Advanced Rectal Cancer

Purpose: To report secondary efficacy endpoints of Radiation Therapy Oncology Group protocol 0247, primary endpoint analysis of which demonstrated that preoperative radiation therapy (RT) with capecitabine plus oxaliplatin achieved a pathologic complete remission prespecified threshold (21%) to merit further study, whereas RT with capecitabine plus irinotecan did not (10%). Methods and Materials: A randomized, phase 2 trial evaluated preoperative RT (50.4 Gy in 1.8-Gy fractions) with 2 concurrent chemotherapy regimens: (1) capecitabine (1200 mg/m{sup 2}/d Monday-Friday) plus irinotecan (50 mg/m{sup 2}/wk × 4); and (2) capecitabine (1650 mg/m{sup 2}/d Monday-Friday) plus oxaliplatin (50 mg/m{sup 2}/wk × 5) for clinical T3 or T4 rectal cancer. Surgery was performed 4 to 8 weeks after chemoradiation, then 4 to 6 weeks later, adjuvant chemotherapy (oxaliplatin 85 mg/m{sup 2}; leucovorin 400 mg/m{sup 2}; 5-fluorouracil 400 mg/m{sup 2}; 5-fluorouracil 2400 mg/m{sup 2}) every 2 weeks × 9. Disease-free survival (DFS) and overall survival (OS) were estimated univariately by the Kaplan-Meier method. Local–regional failure (LRF), distant failure (DF), and second primary failure (SP) were estimated by the cumulative incidence method. No statistical comparisons were made between arms because each was evaluated individually. Results: A total of 104 patients (median age, 57 years) were treated; characteristics were similar for both arms. Median follow-up for RT with capecitabine/irinotecan arm was 3.77 years and for RT with capecitabine/oxaliplatin arm was 3.97 years. Four-year DFS, OS, LRF, DF, and SP estimates for capecitabine/irinotecan arm were 68%, 85%, 16%, 24%, and 2%, respectively. The 4-year DFS, OS, LRF, DF, and SP failure estimates for capecitabine/oxaliplatin arm were 62%, 75%, 18%, 30%, and 6%, respectively. Conclusions: Efficacy results for both arms are similar to other reported studies but suggest that pathologic complete remission is an unsuitable surrogate for traditional survival metrics of clinical outcome. Although it remains uncertain whether the addition of a second cytotoxic agent enhances the effectiveness of fluorouracil plus RT, these results suggest that further study of irinotecan may be warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Timing the Flames: Geostationary Satellite Detection of Diurnally Shifting Stubble Burning in Northwestern India

Post-monsoon open-field stubble burning in northwestern (NW) India—a key agricultural region known as the “breadbasket”—is a longstanding practice used to clear fields. Satellite observations spanning over two decades have revealed significant upward trends in crop production, vegetative greenness, and the frequency of post-harvest fires, with this last contributing to hazardous air quality during the peak burning season (mid-October to mid-November). Since 2022, thermal anomaly data from Aqua-MODIS and SNPP-VIIRS sensors have shown a sharp decline in reported fire events—an observation that contrasts starkly with the concurrent rise in regional aerosol loading detected from space. This apparent discrepancy became particularly pronounced in 2024–2025, prompting a closer examination using high-temporal-resolution imagery from the Advanced Meteorological Imager (AMI) on the geostationary satellite GEO-KOMPSAT-2A. These observations revealed a clear spike in fire-related signals occurring around and after 4:00 p.m. local time, i.e., outside the typical noon to 2:00 p.m. detection window of the MODIS and VIIRS. A fire detection algorithm exploiting the fire-sensitive shortwave-infrared 3.8 μm signal and its contrast to 11.2 μm infrared observations is designed to adopt AMI observations and applied to its multi-year observations (2019–2025). The resulting fire dataset unambiguously shows a gradual shift in stubble burning activity toward the late afternoon hours beginning in 2022 which is underreported by polar-orbiting satellites. The orbital drift of NASA’s MODIS sensor on the Aqua platform allows detection of some of the gradually shifting fires during afternoon hours, but the MODIS still misses a large number of fires occurring around and after 4 p.m. The AMI’s relatively coarse spatial resolution (~4 km), a consequence of its slant viewing geometry over NW India, imposes inherent limitations on quantifying the full extent of fire occurrences. The operational air quality forecasting models currently assimilate satellite fire detections predominantly captured during early afternoon overpasses of the MODIS and VIIRS. The temporal shift in fire activity complicates such forecast, leading to a substantial underestimation of emissions. Intense stubble burning and the resulting air pollution highlight the need for effective crop residue management practices for mitigating the frequency of open biomass burning and thereby reducing episodic degradation of air quality and its associated public health and economic impacts.

post-monsoon stubble burning; northwestern India;↗

Human Capabilities Assessments for Autonomous Missions: A Multi-Team Research Effort to Reduce Risk in the Human-System Integration Architecture for Future Deep-Space Missions

In future exploration missions beyond low earth-orbit, crew will have to execute complex operations and respond to off-nominal events, without real-time support from Mission Control. It is anticipated that increased reliance on automated systems, including human-centric vehicle and information architecture, will need to be designed to support the crew; increased risk to performance, health, and safety may occur if these are not implemented appropriately. The Human Factors and Behavioral Performance Element (HFBP) in the NASA Human Research Program supports research to characterize and mitigate such human health and performance risks, including the Risk of Adverse Outcome Due to Inadequate Human Systems Integration Architecture (HSIA). The HSIA risk addresses the integration of onboard capability and the crew roles and responsibilities necessary to enable the crew to respond effectively and efficiently in the increasingly autonomous mission operations environment. In 2017, HFBP released the “Human Capabilities Assessments for Autonomous Missions” (HCAAM) research topic to address HSIA related questions. HCAAM is a major NASA research effort that has assembled a multidisciplinary team from seven institutions to work closely with design and engineering efforts on research towards developing and refining human performance standards, guidelines and automation tools. The scientific focus is on quantitative assessment of human capabilities relevant to future deep-space missions during which earth/spacecraft communication is so delayed and intermittent that the crew must be able to function autonomously. The integrated strategy of the HCAAM project characterizes human capabilities and limitations related to potential performance decrements during long duration exploration mission spaceflight as relevant to both routine and complex task performance; defines system characteristics that reduce the likelihood or impact of potential decrements in human performance capabilities; performs integrated assessment of intelligent system responses within the context of an operational environment with relevant NASA tools, systems, and data structures in order to determine positive or negative interactions and validate recommended approaches; and proposes specific updates to existing standards and guidelines for inclusion in NASA handbooks for the design of future spacecraft intelligent systems that provide crew performance assessment/feedback, and to also serve as decision-support aids for the onboard crew (i.e., NASA-STD-3001, and NASA/SP-Human Integration Design Handbook (HIDH)). The scientific research vectors being addressed by the seven HCAAM teams include: - crew task performance (accuracy, efficiency) (crew + automation) - crew performance (accuracy, efficiency) - crew Situation Awareness - procedure design and multi-modal enhancement - concurrent tasking (mixed manual + some level of autonomy) - task handover - crew self-planning and time-lining - task design - trust in automation, real-time calibration - human multi-sensory feedback and guidance - human trust in on-board software-based intelligent assistants - virtual assistants The presentation will highlight plans and progress made in each of these research areas as well as the methods by which surrogate astronaut crews in the NASA JSC HERA spaceflight analog facility will function as human test subjects for all of the HCAAM research projects.

HCAAM VNSCOR↗

An Instrument to Enable Identification of Anthropogenic CO2 Emissions Using Concurrent CO Measurements

We have developed an instrument concept that will enable the measurement of CO from the top of the atmosphere to the Earth's surface with very high sensitivity and at the high spatial and temporal resolutions required by the NRC Decadal Survey mission Active Sensing of Carbon Dioxide (CO2) over Nights, Days and Seasons (ASCENDS). We are developing an innovative CO sensor that will enable the ASCENDS mission to differentiate between anthropogenic and natural sources and sinks of global carbon. The NRC Decadal Survey places particular emphasis on retrieving CO information for the planetary boundary layer. Measurement made using both the 2.3 micron and 4.7 micron channels are needed to achieve the sensitivity required in the lower atmosphere where the degree of CO - CO2 correlation is indicative of anthropogenic sources of CO2. Measurements made using only the 4.7 micron channel cannot provide sufficient sensitivity to CO in the very lowest layers of the atmosphere. The fundamental method we use is Gas Filter Correlation Radiometry (GFCR), a highly successful technique used in other airborne and space-based missions for detecting trace species in the Earth's atmosphere. Our version of GFCR overcomes many of the limitations encountered by prior and existing instruments, allowing us to measure weak signals from small targets very quickly and with extremely high specificity by employing a new dual beam radiometer concept using a focal plane array. Our design will provide a means to make the desired CO measurements for the ASCENDS mission. A simple change in gas filter cell contents would allow the same hardware to measure CH4 with high precision under the nominal ASCENDS mission spatial and temporal constraints. All critical components in the sensor design are mature, many subsystems tested, and the system has been extensively modeled, bringing it to a present Technology Readiness Level (TRL) of 3 (though some individual components are at TRLs 6-9). We are presently developing critical components for the new spectrometer and advancing our understanding of the measurement requirements for both CO and CH4. This new GFCR technique/sensor will enable measurements of trace gases with high sensitivity while maintaining the inherent robustness and simplicity of the more traditional radiometer hardware. Initial estimates of cost/risk of a spacebased 2-channel GFCR indicate that our design is extremely cost effective and will fit within existing ASCENDS mission budget constraints as determined by the NRC Decadal Survey and a NASA-sponsored mission study.

Cook, William B.↗

A GPS-Based Pitot-Static Calibration Method Using Global Output-Error Optimization

Pressure-based airspeed and altitude measurements for aircraft typically require calibration of the installed system to account for pressure sensing errors such as those due to local flow field effects. In some cases, calibration is used to meet requirements such as those specified in Federal Aviation Regulation Part 25. Several methods are used for in-flight pitot-static calibration including tower fly-by, pacer aircraft, and trailing cone methods. In the 1990 s, the introduction of satellite-based positioning systems to the civilian market enabled new inflight calibration methods based on accurate ground speed measurements provided by Global Positioning Systems (GPS). Use of GPS for airspeed calibration has many advantages such as accuracy, ease of portability (e.g. hand-held) and the flexibility of operating in airspace without the limitations of test range boundaries or ground telemetry support. The current research was motivated by the need for a rapid and statistically accurate method for in-flight calibration of pitot-static systems for remotely piloted, dynamically-scaled research aircraft. Current calibration methods were deemed not practical for this application because of confined test range size and limited flight time available for each sortie. A method was developed that uses high data rate measurements of static and total pressure, and GPSbased ground speed measurements to compute the pressure errors over a range of airspeed. The novel application of this approach is the use of system identification methods that rapidly compute optimal pressure error models with defined confidence intervals in nearreal time. This method has been demonstrated in flight tests and has shown 2- bounds of approximately 0.2 kts with an order of magnitude reduction in test time over other methods. As part of this experiment, a unique database of wind measurements was acquired concurrently with the flight experiments, for the purpose of experimental validation of the optimization method. This paper describes the GPS-based pitot-static calibration method developed for the AirSTAR research test-bed operated as part of the Integrated Resilient Aircraft Controls (IRAC) project in the NASA Aviation Safety Program (AvSP). A description of the method will be provided and results from recent flight tests will be shown to illustrate the performance and advantages of this approach. Discussion of maneuver requirements and data reduction will be included as well as potential applications.

Foster, John V.↗

Whole-Pelvis or Bladder-Only Chemoradiation for Lymph Node-Negative Invasive Bladder Cancer: Single-Institution Experience

Purpose: Whole-pelvis (WP) concurrent chemoradiation (CCRT) is the standard bladder preserving option for patients with invasive bladder cancer. The standard practice is to treat elective pelvic lymph nodes, so our aim was to evaluate whether bladder-only (BO) CCRT leads to results similar to those obtained by standard WP-CCRT. Methods and Materials: Patient eligibility included histopathologically proven muscle-invasive bladder cancer, lymph nodes negative (T2-T4, N-) by radiology, and maximal transurethral resection of bladder tumor with normal hematologic, renal, and liver functions. Between March 2005 and May 2006, 230 patients were accrued. Patients were randomly assigned to WP-CCRT (120 patients) and BO-CCRT (110 patients). Data regarding the toxicity profile, compliance, initial complete response rates at 3 months, and occurrence of locoregional or distant failure were recorded. Results: With a median follow-up time of 5 years (range, 3-6), WP-CCRT was associated with a 5-year disease-free survival of 47.1% compared with 46.9% in patients treated with BO-CCRT (p = 0.5). The bladder preservation rates were 58.9% and 57.1% in WP-CCRT and BO-CCRT, respectively (p = 0.8), and the 5-year overall survival rates were 52.9% for WP-CCRT and 51% for BO-CCRT (p = 0.8). Conclusion: BO-CCRT showed similar rates of bladder preservation, disease-free survival, and overall survival rates as those of WP-CCRT. Smaller field sizes including bladder with 2-cm margins can be used as bladder preservation protocol for patients with muscle-invasive lymph node-negative bladder cancer to minimize the side effects of CCRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Iron site occupancies in magnetite-ulvospinel solid solution: A new approach using XMCD

Ordering of Fe{sup 3+} and Fe{sup 2+} between octahedral (Oh) and tetrahedral (Td) sites in synthetic members of the magnetite (Fe{sub 3}O{sub 4}) - ulvoespinel (Fe{sub 2}TiO{sub 4}) solid-solution series was determined using Fe L{sub 2,3}-edge X-ray magnetic circular dichroism (XMCD) coupled with electron microprobe and chemical analysis, Ti L-edge spectroscopy, Fe K-edge EXAFS and XANES, Fe{sub 57} Moessbauer spectroscopy, and unit cell parameters. Microprobe analysis, cell edges and chemical FeO determinations showed that the bulk compositions of the samples were stoichiometric magnetite-ulvoespinel solid-solutions. Surface sensitive XMCD showed that the surfaces of these oxide minerals were more sensitive to redox conditions and some samples required re-equilibration with suitable solid-solid buffers. Detailed site-occupancy analysis of these samples gave XMCD-Fe{sup 2+}/Fe{sup 3+} ratios very close to stoichiometric values. L{sub 2,3}-edge spectroscopy showed that Ti{sup 4+} was restricted to Oh sites. XMCD results showed that significant Fe{sup 2+} only entered Td when the Ti content was > 0.40 apfu while Fe{sup 2+} in Oh increased from 1 a.p.f.u in magnetite to a maximum of {approx}1.4 apfu in USP45. As the Ti content increased from this point, the steady increase in Fe{sup 2+} in Td sites was clearly observable in the XMCD spectra, concurrent with a slow decrease in Fe{sup 2+} in Oh sites. Calculated magnetic moments showed a steady decrease from magnetite (4.06 {mu}{sub B}) to USP45 (1.5 {mu}{sub B}) and then a slower decrease towards the value for ulvoespinel (0 {mu}{sub B}). Two of the synthesized samples were also partially maghemitized by re-equilibrating with an oxidizing Ni-NiO buffer and XMCD showed that Fe{sup 2+} oxidation only occurred at Oh sites, with concomitant vacancy formation restricted to this site. This study shows the advantage of using XMCD as a direct measurement of Fe oxidation state in these complex magnetic spinels. These results can be used to rationalize the magnetic properties of titanomagnetites, and their oxidized titanomaghemitized analogues, in Earth's crustal rocks.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hyperthermia and Radiation Therapy in Locoregional Recurrent Breast Cancers: A Systematic Review and Meta-analysis

Purpose: To conduct a systematic review and meta-analysis to evaluate the outcome of hyperthermia (HT) and radiation therapy (RT) in locally recurrent breast cancers (LRBCs). Methods and Materials: A total of 708 abstracts were screened from 8 databases according to the PRISMA guidelines. Single-arm and 2-arm studies, treating LRBCs with HT and RT but without surgery (for local recurrence) or concurrent chemotherapy were considered. The evaluated endpoint was complete response (CR). Results: Thirty-one full text articles, pertaining to 34 studies, were shortlisted for the meta-analysis. Eight were 2-arm (randomized, n=5; nonrandomized, n=3), whereas 26 were single-arm studies. In all, 627 patients were enrolled in 2-arm and 1483 in single-arm studies. Patients were treated with a median of 7 HT sessions, and an average temperature of 42.5°C was attained. Mean RT dose was 38.2 Gy (range, 26-60 Gy). Hyperthermia was most frequently applied after RT. In the 2-arm studies, a CR of 60.2% was achieved with RT + HT versus 38.1% with RT alone (odds ratio 2.64, 95% confidence interval [CI] 1.66-4.18, P<.0001). Risk ratio and risk difference were 1.57 (95% CI 1.25-1.96, P<.0001) and 0.22 (95% CI 0.11-0.33, P<.0001), respectively. In 26 single-arm studies, RT + HT attained a CR of 63.4% (event rate 0.62, 95% CI 0.57-0.66). Moreover, 779 patients had been previously irradiated (696 from single-arm and 83 from 2-arm studies). A CR of 66.6% (event rate 0.64, 95% CI 0.58-0.70) was achieved with HT and reirradiation (mean ± SD dose: 36.7 ± 7.7 Gy). Mean acute and late grade 3/4 toxicities with RT + HT were 14.4% and 5.2%, respectively. Conclusions: Thermoradiation therapy enhances the likelihood of CR rates in LRBCs over RT alone by 22% with minimal acute and late morbidities. For even those previously irradiated, reirradiation with HT provides locoregional control in two-thirds of the patients. Thermoradiation therapy could therefore be considered as an effective and safe palliative treatment option for LRBCs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Singular value decomposition utilizing parallel algorithms on graphical processors

One of the current challenges in underwater acoustic array signal processing is the detection of quiet targets in the presence of noise. In order to enable robust detection, one of the key processing steps requires data and replica whitening. This, in turn, involves the eigen-decomposition of the sample spectral matrix, Cx = 1/K xKX(k)XH(k) where X(k) denotes a single frequency snapshot with an element for each element of the array. By employing the singular value decomposition (SVD) method, the eigenvectors and eigenvalues can be determined directly from the data without computing the sample covariance matrix, reducing the computational requirements for a given level of accuracy (van Trees, Optimum Array Processing). (Recall that the SVD of a complex matrix A involves determining V, , and U such that A = U VH where U and V are orthonormal and is a positive, real, diagonal matrix containing the singular values of A. U and V are the eigenvectors of AAH and AHA, respectively, while the singular values are the square roots of the eigenvalues of AAH.) Because it is desirable to be able to compute these quantities in real time, an efficient technique for computing the SVD is vital. In addition, emerging multicore processors like graphical processing units (GPUs) are bringing parallel processing capabilities to an ever increasing number of users. Since the computational tasks involved in array signal processing are well suited for parallelization, it is expected that these computations will be implemented using GPUs as soon as users have the necessary computational tools available to them. Thus, it is important to have an SVD algorithm that is suitable for these processors. This work explores the effectiveness of two different parallel SVD implementations on an NVIDIA Tesla C2050 GPU (14 multiprocessors, 32 cores per multiprocessor, 1.15 GHz clock - peed). The first algorithm is based on a two-step algorithm which bidiagonalizes the matrix using Householder transformations, and then diagonalizes the intermediate bidiagonal matrix through implicit QR shifts. This is similar to that implemented for real matrices by Lahabar and Narayanan ("Singular Value Decomposition on GPU using CUDA", IEEE International Parallel Distributed Processing Symposium 2009). The implementation is done in a hybrid manner, with the bidiagonalization stage done using the GPU while the diagonalization stage is done using the CPU, with the GPU used to update the U and V matrices. The second algorithm is based on a one-sided Jacobi scheme utilizing a sequence of pair-wise column orthogonalizations such that A is replaced by AV until the resulting matrix is sufficiently orthogonal (that is, equal to U ). V is obtained from the sequence of orthogonalizations, while can be found from the square root of the diagonal elements of AH A and, once is known, U can be found from column scaling the resulting matrix. These implementations utilize CUDA Fortran and NVIDIA's CUB LAS library. The primary goal of this study is to quantify the comparative performance of these two techniques against themselves and other standard implementations (for example, MATLAB). Considering that there is significant overhead associated with transferring data to the GPU and with synchronization between the GPU and the host CPU, it is also important to understand when it is worthwhile to use the GPU in terms of the matrix size and number of concurrent SVDs to be calculated.

99 GENERAL AND MISCELLANEOUS↗