Search NASA⌕ Search

SEARCH · Search NASA

Results for “Deployable Power Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

RFA for Solar/Geothermal Hybrid Thermal Energy Storage Modeling: Cooperative Research and Development Final Report, CRADA Number CRD-16-646

Hyperlight Energy is an innovative concentrated solar power (CSP) company whose business charter is to commercialize a disruptively low-cost, CSP collector system that is ultimately for providing heat for solar thermal/geothermal hybrid power plants, process heat applications (e.g., enhanced oil recovery), and solar thermal power generation. Hyperlight's CSP collector system utilizes a linear Fresnel reflector (LFR) configuration. This LFR configuration consists of mirrors mounted in low-cost, precision plastic extrusions, which are integrated into raft assemblies and floated on low-cost, sealed waterbeds. Hyperlight's CSP collector technology has been developed under private equity investment, government grant and commercial funding. Hyperlight has been awarded a 1.5-million DOE COLLECTS contract with an additional 1.6 million in matched funds from private investment and the California Energy Commission. This DOE project will support the final steps of product development for bulk commercialization and deployment of the Hyperlight CSP collector system. The work will culminate in a final operational deployment at a commercially relevant site. Several such site options are currently under evaluation, including two geothermal sites. Hyperlight identified a very low-cost way to put renewable energy electrons on the grid at peak times, upgrading underutilized geothermal plants with Hyperlight's low cost CSP and thermal energy storage (TES). While Hyperlight's CSP collector work is maturing quickly for commercial pilot launch, an optimal TES system for solar thermal/geothermal hybridization needs to be evaluated and ultimately developed so Hyperlight can develop commercial retrofit projects at a scale of hundreds of megawatts of renewable energy power output at sites across the United States, followed by greenfield projects in a multi-GW sized market.

15 GEOTHERMAL ENERGY↗

Impacts of Federal Tax Credit Extensions on Renewable Deployment and Power Sector Emissions

Federal tax credits for renewable energy (RE) have served as one of the primary financial incentives for RE deployment over the last two decades in the United States. In December 2015, the wind power production tax credit and solar investment tax credits were extended for five years as part of the Consolidated Appropriations Act of 2016. This report explores the impact that these tax credit extensions might have on future RE capacity deployment and power sector carbon dioxide (CO2) emissions. The analysis examines the impacts of the tax credit extensions under two distinct natural gas price futures as natural gas prices have been key factors in influencing the economic competitiveness of new RE development. The analysis finds that, in both natural gas price futures, RE tax credit extensions can spur RE capacity investments at least through the early 2020s and can help lower emissions from the U.S. electricity system. More specifically, the RE tax credit extensions are estimated to drive a net peak increase of 48-53 GW in installed RE capacity in the early 2020s -- longer term impacts are less certain. In the longer term after the tax credits ramp down, greater RE capacity is driven by a combination of assumed RE cost declines, rising fossil fuel prices, and other clean energy policies such as the Clean Power Plan. The tax credit extension-driven acceleration in RE capacity development can reduce fossil fuel-based generation and lower electric sector CO2 emissions. Cumulative emissions reductions over a 15-year period (spanning 2016-2030) as a result of the tax credit extensions are estimated to range from 540 to 1420 million metric tonnes CO2. These findings suggest that tax credit extensions can have a measurable impact on future RE deployment and electric sector CO2 emissions under a range of natural gas price futures.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Collaboration as a second thought.

Collaboration is often an afterthought to a project or development. In this paper we describe and analyze our experiences in developing collaborative technologies, most often involving the sharing of visual information. We have often developed these in a context that required us to retrofit existing analysis applications with collaboration capabilities. This approach, though fruitful, is time-consuming, expensive, and often difficult to re-apply elsewhere - it is just hard to change an existing application. One way to make such an effort easier is to package the collaborative components as a kit that can be leveraged on a case-by-case basis. The fixed interface provided by a well-designed toolkit eases the integration process by providing an unchanging and familiar set of components to deploy. Better still, we find, are approaches that require no modification of applications while providing rich and powerful means for sharing information with collaborators. We discuss three separate and illuminating examples that meet this criterion in different ways: (1) building the collaborative potential into the underlying abstractions on which operating systems are built, (2) building tools that live side-by-side with any application in the context provided by the operating system, or by (3) building information tools that use collaborative modalities to better integrate with our workflow. These are probably not the only options, but they all derive from an approach where collaboration is considered early in the design process and therefore manifests itself deep in the computing infrastructure giving it a wider cast.

97 MATHEMATICS AND COMPUTING↗

Data-Driven Distribution System Coordinated PV Inverter Control Using Deep Reinforcement Learning

The deployment of distributed solar photovoltaic (PV) systems has increased consistently over the past decades. High penetrations of PVs could cause a series of adverse grid impacts, such as voltage violations. The recent development of smart inverter technologies rises the incentives of developing PV control solutions that regulate the inverter output power and seeking the optimization on system operational objectives. This paper proposes a data-driven control solution based on deep reinforcement learning (DRL) to optimize PV inverters for voltage regulation. The proposed solution can minimize PV real power curtailment while maintaining network voltage at an acceptable range. Comparison results between the proposed DRL control algorithms with deep deterministic policy gradient (DDPG) and volt-var control on a real feeder in west Colorado highlight the advantage of the proposed framework in controlling the system voltage while minimizing the PV real power curtailment.

deep reinforcement learning↗

System Design of Dynamic Wireless Power Transfer for Automated Highways

Dynamic wireless power transfer (DWPT) has been proposed as a solution to power electric vehicles (EVs)on future electrified highways. However, there has been little consideration of how the coordination of electric connected and automated vehicles (CAVs) could impact DWPT system designs in future scenarios. In this paper, a DWPT system design is optimized for a future highway where CAVs travel in coordinated groups, with each CAV in the group powered by the same DWPT section. As the distribution of smaller light-duty vehicles (LDVs) and larger heavy-duty vehicles (HDVs) in each group is varied, the DWPT system power level, transmitter length, and the equivalent receiver loads are adjusted to minimize the infrastructure requirements and energy losses of the DWPT system. The outputs from this analysis are used to determine the optimal groupings of vehicles for a given DWPT system. The analysis suggests that CAV coordination could aid the deployment of DWPT systems and reduce the overall infrastructure and energy losses of DWPT systems.

Foote, Andrew↗

High-fidelity kinetic modeling of plasmas in Z-pinch and pulsed power configurations (18-ERD-048)

Plasma dynamics can be strongly influenced by fine-scale kinetic physics, which is not captured by standard fluid treatments, is challenging to simulate, and is poorly understood. The aim of this research was to investigate the fundamental fine-scale properties of collisionless plasmas in Z-pinch and pulsed power configurations by deploying novel noisefree high-accuracy computational algorithms. Significant advances were achieved through the development of robust numerical capabilities to exploit axisymmetry in kinetic simulations, the development of new methodologies to construct kinetic equilibria, and the theoretical and computational study of kinetic sheared-flow-driven transport in pulsed power systems. These new capabilities shed light on the anisotropies that can develop in Z-pinches and the transport processes that can lead to parasitic currents in pulsed power inertial confinement fusion experiments. The use of cutting-edge massively-parallel numerical algorithms to address outstanding scientific questions in plasma physics advances the mission of Lawrence Livermore National Laboratory in the areas of high energy density science and high performance computing. By bringing together kinetic theory, high-order numerical methods, high performance computing, and experimental applications, this research advances the state of the art in plasma physics modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

R$\&$D of Power Over Fiber in harsh environments and its novel application for the DUNE Photon Detection System

The Deep Underground Neutrino Experiment (DUNE) is a next generation long-baseline neutrino experiment that will send an intense beam of neutrinos through two detector complexes: a near detector complex located at Fermilab (Chicago), and a far detector complex located $\sim$ 1.5 km underground at Sanford Underground Research Facility (SURF) in South Dakota. One of the DUNE Far Detector (FD) modules will employ the Vertical Drift (VD) Technology, which will vertically drift the ionized electrons from the cathode plane suspended at the mid-height of the active volume of the cryostat. The Photon Detection System (PDS) will be installed along the cathode and behind the field cage to increase the photon detection coverage. Due to the high voltage ($\sim$300 kV) present at the cathode, conventional copper cables cannot be used to power the photon detectors. Therefore, Power-over-Fiber (PoF) technology will be deployed to power the PDS based on optical power transmission over optical fibers. This poster presents the R$&$D campaign on different PoF components under harsh environments and its novel application in the DUNE PDS.

Martinez caicedo, David Alejandro [South Dakota Sc↗

Performance Evaluation of Hierarchical Controls for Advanced Distribution Management System-Centered Grid Operations: Preprint

This paper presents a hardware-in-the-loop (HIL) platform to evaluate the performance of voltage regulation using an advanced distribution management system (ADMS) for grid operations to control legacy and grid-edge voltage control devices and coordinate with distributed energy management systems (DERMS) to manage high penetrations of photovoltaics (PV) on a utility distribution system. The HIL platform provides realistic laboratory testing, including accurate modeling (legacy devices, grid-edge devices, and PV) of the real-world distribution system from a utility partner, a real controller (ADMS), software controller DERMS, hardware grid-edge devices, and standard communications protocols. The test results show proper functionalities of the integrated platform and the performance of voltage regulation of the coordinated control systems. Based on laboratory testing, the utility can set up the same grid-automation system to manage DERs, legacy devices, and grid-edge devices to achieve their system-level control and operation objectives (e.g., voltage regulation), thus de-risking potential issues (e.g., instability) for field deployment.

ADMS↗

Zero-power wireless system for crop water content monitoring

Zero power wireless sensors, devices, and systems are used for crop water content monitoring. The sensors consume no power while monitoring for the presence of dry crop conditions. Infrared reflectance from plants is measured and when selected spectral conditions are met, a circuit is closed, activating an alarm, an RFID tag, or a radio transmitter. The deployed sensors consume no power while monitoring, reducing or eliminating the need to change batteries.

Rinaldi, Matteo↗

ADX: a high field, high power density, advanced divertor and RF tokamak

The MIT Plasma Science and Fusion Center and collaborators are proposing a high-performance Advanced Divertor and RF tokamak eXperiment (ADX) – a tokamak specifically designed to address critical gaps in the world fusion research program on the pathway to next step devices: fusion nuclear science facility (FNSF), fusion pilot plant (FPP), and/or demonstration power plant (DEMO). This high field (≥ 6.5 tesla, 1.5 MA), high power density facility (P/S ~ 1.5 MW/m2) will test innovative divertor ideas, including an ‘X-point target divertor’ concept, at the required performance parameters – reactor-level boundary plasma pressures, magnetic field strengths and parallel heat flux densities entering into the divertor region – while simultaneously producing high performance core plasma conditions that are prototypical of a reactor: equilibrated electrons and ions, regimes with low or no torque, and no fueling from external heating and current drive systems. Equally important, the experimental platform will test innovative concepts for lower hybrid current drive (LHCD) and ion-cyclotron range of frequency (ICRF) actuators with the unprecedented ability to deploy launch structures both on the lowmagnetic- field side and the high-magnetic-field side – the latter being a location where energetic plasma-material interactions can be controlled and favorable RF wave physics leads to efficient current drive, current profile control, heating and flow drive. This triple combination – advanced divertors, advanced RF actuators, reactor-prototypical core plasma conditions – will enable ADX to explore enhanced core confinement physics, such as made possible by reversed central shear, using only the types of external drive systems that are considered viable for a fusion power plant. Such an integrated demonstration of high-performance core-divertor operation with steady state sustainment would pave the way toward an attractive pilot plant, as envisioned in the ARC concept (Affordable, Robust, Compact) [B. N. Sorbom, et al., submitted to Fusion Engineering Design, 2014] that makes use of high-temperature superconductor technology – a high-field (9.25 tesla) tokamak the size of the Joint European Torus that produces 270 MW of net electricity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence on Structural Loading of a Wave Energy Converter by Controlling Variable-Geometry Components and the Power Take-Off: Preprint

Oceans are a harsh environment and can impose significant loads on deployed structures. Deployment of wave energy converters (WECs) faces a design challenge with apparently contradictory goals. A WEC should be designed to maximize the energy absorbed while ensuring the operating wave condition does not exceed the failure limits of the device itself. Therefore, the loads endured by the support structure are a design constraint for the system. Adaptability to different sea states is, therefore, highly desirable. This work uses a WEC-Sim model of a Variable Geometry Oscillating Wave Energy Converter (VGOSWEC) mounted on a support structure simulated under different wave scenarios. A VGOSWEC resembles a paddle pitching about a fixed hinge perpendicular to the incoming waves-fronts. Therefore, the hinge experiences loads perpendicular to its axis as it maintains its position. The geometry of the VGOSWEC was varied by opening a series of controllable flaps on the pitching paddle when the structure experiences threshold loads. Since opening the flaps lets the waves transmit through the paddle, it is hypothesized that opening the flaps should result in load shedding at the base of the support structure. This load shedding is achieved by reducing the moments about the hinge axis. This work compares the hydrodynamic coefficients, natural periods, and Response Amplitude Operators (RAOs) from completely closed to completely open configurations of the controllable flaps. These comparisons quantify the effects of letting the waves transmit through the VGOSWEC. This work shows that the completely open configuration can reduce the pitch and surge loads on the base of the support structure by as much as 80%. It was observed that at the paddle's resonance frequency, the loads on the structure increased substantially. This increase in loads can be mitigated by a rotational Power Take-off (PTO) damping about the hinge axis. Changing the rotational PTO damping was identified as an additional design parameter that can be used to control the loads experienced by the WEC's support structure.

fixed and floating structures↗

Transient Stability Study of a Real-World Microgrid with 100% Renewables

This paper performs a transient stability study of a real-world microgrid that can operate with 100% renewables to better understand the stability and reliability of the microgrid under various dynamic scenarios. In particular, the operation of multiple grid-forming (GFM) and grid-following (GFL) inverters in such a power system is not well understood under dynamic operation conditions, such as islanding and black start; therefore, in this paper, an electromagnetic transient model of the microgrid is developed to investigate the stability of the system under various dynamic operating conditions and to identify potential reliability risks. The PSCAD/EMTDC simulation with the high-fidelity model provides helpful insights into the optimal operation modes of GFM and GFL inverters as well as the stability and reliability of the microgrid. It can also inform field deployment in terms of inverter control parameters and coordination as well as the expected performance of black start and unplanned islanding.

black start↗

Northwest Open Automated Demand Response Technology Demonstration Project

The Lawrence Berkeley National Laboratory (LBNL) Demand Response Research Center (DRRC) demonstrated and evaluated open automated demand response (OpenADR) communication infrastructure to reduce winter morning and summer afternoon peak electricity demand in commercial buildings the Seattle area. LBNL performed this demonstration for the Bonneville Power Administration (BPA) in the Seattle City Light (SCL) service territory at five sites: Seattle Municipal Tower, Seattle University, McKinstry, and two Target stores. This report describes the process and results of the demonstration. OpenADR is an information exchange model that uses a client-server architecture to automate demand-response (DR) programs. These field tests evaluated the feasibility of deploying fully automated DR during both winter and summer peak periods. DR savings were evaluated for several building systems and control strategies. This project studied DR during hot summer afternoons and cold winter mornings, both periods when electricity demand is typically high. This is the DRRC project team's first experience using automation for year-round DR resources and evaluating the flexibility of commercial buildings end-use loads to participate in DR in dual-peaking climates. The lessons learned contribute to understanding end-use loads that are suitable for dispatch at different times of the year. The project was funded by BPA and SCL. BPA is a U.S. Department of Energy agency headquartered in Portland, Oregon and serving the Pacific Northwest. BPA operates an electricity transmission system and markets wholesale electrical power at cost from federal dams, one non-federal nuclear plant, and other non-federal hydroelectric and wind energy generation facilities. Created by the citizens of Seattle in 1902, SCL is the second-largest municipal utility in America. SCL purchases approximately 40% of its electricity and the majority of its transmission from BPA through a preference contract. SCL also provides ancillary services within its own balancing authority. The relationship between BPA and SCL creates a unique opportunity to create DR programs that address both BPA's and SCL's markets simultaneously. Although simultaneously addressing both market could significantly increase the value of DR programs for BPA, SCL, and the end user, establishing program parameters that maximize this value is challenging because of complex contractual arrangements and the absence of a central Independent System Operator or Regional Transmission Organization in the northwest.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing the system value of optimal load shifting

We analyze a competitive electricity market, where consumers exhibit optimal load shifting behavior to maximize utility and producers/suppliers maximize their profit under supply capacity constraints. The associated computationally tractable formulation can be used to inform market design or policy analysis in the context of increasing availability of the smart grid technologies that enable optimal load shifting. Through analytic and numeric assessment of the model, we assess the equilibrium value of optimal electricity load shifting, including how the value changes as more electricity consumers adopt associated technologies. For our illustrative numerical case, derived from the Current Trends scenario of the ERCOT Long Term System Assessment, the average energy arbitrage value per ERCOT customer of optimal load shifting technologies is estimated to be $3 for the 2031 scenario year. We assess the sensitivity of this result to the flexibility of load, along with its relationship to the deployment of renewables. Finally, the model presented can also be a starting point for designing system operation infrastructure that communicates with the devices that schedule loads in response to price signals.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Post-Deployment Characterization of Glass Fiber-Reinforced Thermoset and Thermoplastic Composite Tidal Turbine Blades: Preprint

In 2021, the National Renewable Energy Laboratory (NREL) supported Verdant Power with the most successful tidal energy deployment in U.S. history. Three of their tidal turbines were deployed as part of the Roosevelt Island Tidal Energy project. Initially, the three rotors were manufactured from glass fiber-reinforced epoxy composites. Midway through the deployment, one rotor was replaced with one manufactured at NREL. Instead, it was infused with a novel, infusible thermoplastic resin system. Since the deployment, one epoxy rotor and one thermoplastic rotor were returned to NREL for continued materials and manufacturing research. The two rotors underwent full-scale structural testing before being sectioned and cut into specimens for a variety of manufacturing quality tests, thermos-mechanical characterization, and evaluation of material performance in marine environments, to understand the key differences between the fiberglass reinforced epoxy and Elium composites used for the respective rotors. Matrix burnoff tests showed that the Elium blades had a considerably higher fiber volume fraction compared to the epoxy blades (61% vs. 49%). Environmental aging of the specimens showed that the epoxy laminates absorbed more water over the conditioning period, however, it was determined that the Elium laminates had higher diffusion coefficients, so initially absorbed water faster. Finally, one full epoxy blade and one full Elium blade were conditioned at ambient temperatures for up to 11 months, while taking periodic mass measurements. The datasets were extrapolated out to assume a full 20 year operational life span and it was determined that the blades would not reach full saturation during that time span.

composite manufacturing↗

Atmospheric Radiation Measurement program climate research facility operations quarterly report October 1 - December 31, 2007.

Individual raw data streams from instrumentation at the Atmospheric Radiation Measurement (ARM) Program Climate Research Facility (ACRF) fixed and mobile sites are collected and sent to the Data Management Facility (DMF) at Pacific Northwest National Laboratory (PNNL) for processing in near real time. Raw and processed data are then sent daily to the ACRF Archive, where they are made available to users. For each instrument, we calculate the ratio of the actual number of data records received daily at the Archive to the expected number of data records. The results are tabulated by (1) individual data stream, site, and month for the current year and (2) site and fiscal year (FY) dating back to 1998. Table 1 shows the accumulated maximum operation time (planned uptime), actual hours of operation, and variance (unplanned downtime) for the period October 1 - December 31, 2007, for the fixed sites and the mobile site. The AMF has been deployed to Germany and this was the final operational quarter. The first quarter comprises a total of 2,208 hours. Although the average exceeded our goal this quarter, a series of severe weather events (i.e., widespread ice storms) disrupted utility services, which affected the SGP performance measures. Some instruments were covered in ice and power and data communication lines were down for more than 10 days in some areas of Oklahoma and Kansas, which resulted in lost data at the SGP site. The Site Access Request System is a web-based database used to track visitors to the fixed sites, all of which have facilities that can be visited. The NSA locale has the Barrow and Atqasuk sites. The SGP site has a central facility, 23 extended facilities, 4 boundary facilities, and 3 intermediate facilities. The TWP locale has the Manus, Nauru, and Darwin sites. The AMF completed its mission at the end of this quarter in Haselback, Germany (FKB designation). NIM represents the AMF statistics for the Niamey, Niger, Africa, past deployment in 2006. PYE represents just the AMF Archive statistics for the Point Reyes, California, past deployment in 2005. In addition, users who do not want to wait for data to be provided through the ACRF Archive can request an account on the local site data system. The eight research computers are located at the Barrow and Atqasuk sites; the SGP central facility; the TWP Manus, Nauru, and Darwin sites; the DMF at PNNL; and the AMF, currently in Germany. In addition, the ACRF serves as a data repository for a long-term Arctic atmospheric observatory in Eureka, Canada (80 degrees 05 minutes N, 86 degrees 43 minutes W) as part of the multiagency Study of Environmental Arctic Change (SEARCH) Program. NOAA began providing instruments for the site in 2005, and currently cloud radar data are available. The intent of the site is to monitor the important components of the Arctic atmosphere, including clouds, aerosols, atmospheric radiation, and local-scale atmospheric dynamics. Due to the similarity of ACRF NSA data streams, and the important synergy that can be formed between a network of Arctic atmospheric observations, much of the SEARCH observatory data are archived in the ARM archive. Instruments will be added to the site over time. For more information, please visit http://www.db.arm.gov/data. The designation for the archived Eureka data is YEU and is now included in the ACRF user metrics. This quarterly report provides the cumulative numbers of visitors and user accounts by site for the period January 1, 2007 - December 31, 2007. Table 2 shows the summary of cumulative users for the period January 1, 2007 - December 31, 2007. For the first quarter of FY 2008, the overall number of users was up significantly from the last reporting period. For the fourth consecutive reporting period, a record high number of Archive users was recorded. In addition, the number of visitors and visitor days set a new record this reporting period particularly due to the large number of field campaign activities in conjunction with the AMF deployment in Germany. It is interesting to note this quarter that 22% (a slight decrease from last quarter) of the Archive users are ARM Science funded principal investigators and 35% (the same as last quarter) of all other facility users are either ARM Science-funded principal investigators or ACRF infrastructure personnel. For reporting purposes, the three ACRF sites and the AMF operate 24 hours per day, 7 days per week, and 52 weeks per year. Time is reported in days instead of hours. If any lost work time is incurred by any employee, it is counted as a workday loss. Table 3 reports the consecutive days since the last recordable or reportable injury or incident causing damage to property, equipment, or vehicle for the period October 1 - December 31, 2007. There were no incidents this reporting period.

54 ENVIRONMENTAL SCIENCES↗

Systems Integration (Fact Sheet)

The Systems Integration (SI) subprogram works closely with industry, universities, and the national laboratories to overcome technical barriers to the large-scale deployment of solar technologies. To support these goals, the subprogram invests primarily in four areas: grid integration, technology validation, solar resource assessment, and balance of system development.

systems integration, grid integration, solar, sola↗

Transient Stability Study of a Real-World Microgrid with 100% Renewables

This paper performs a transient stability study of a real-world microgrid that can operate with 100% renewables to better understand the stability and reliability of the microgrid under various dynamic scenarios. In particular, the operation of multiple grid-forming (GFM) and grid-following (GFL) inverters in such a power system is not well understood under dynamic operation conditions, such as islanding and black start; therefore, in this paper, an electromagnetic transient model of the microgrid is developed to investigate the stability of the system under various dynamic operating conditions and to identify potential reliability risks. The PSCAD/EMTDC simulation with the high-fidelity model provides helpful insights into the optimal operation modes of GFM and GFL inverters as well as the stability and reliability of the microgrid. It can also inform field deployment in terms of inverter control parameters and coordination as well as the expected performance of black start and unplanned islanding.

black start↗