Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Silicon-tungsten Electromagnetic Calorimetry

A highly granular silicon-tungsten electromagnetic calorimeter has been designed and modelled, and a partial prototype was constructed, tested and evaluated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary Survey on the Effectiveness of an Electromagnetic Dampener to Improve System Shielding Effectiveness

This report explores the potential for reducing the fields and the quality factor within a system cavity by introducing microwave absorbing materials. Although the concept of introducing absorbing (lossy) materials within a cavity to drive the interior field levels down is well known, increasing the loading into a complex weapon cavity specifically for improved electromagnetic performance has not, in general, been considered, and this will be the subject of this work. We compare full-wave simulations to experimental results, demonstrating the applicability of the proposed method.

42 ENGINEERING↗

High Voltage Modeling and Testing of Transformer, Line Interface Devices, and Bulk System Components Under Electromagnetic Pulse, Geomagnetic Disturbance, and other Abnormal Transients

This project aims at quantitatively analyzing possible knowledge gaps related to the risk of Electromagnetic Pulse (EMP) impact on high-voltage, power transformers (transmission-class), that represent the most critical power grid assets. In relation to the electric infrastructure, some past studies indicate that the grid is overall fairly robust and resilient against most EMP threats. This assessment stems, in part, from estimates of the peak voltage that can be induced on a transmission power line for a nominal EMP fast-transient, compared with the typically very high basic insulation level that is featured by the high-voltage infrastructure. The project provides additional insight toward a more comprehensive risk evaluation of the grid EMP and Geomagnetic Disturbances (GMD) vulnerabilities. This work is aligned with the U.S. Dept. of Energy current research thrust in support of the development of a highly secure and resilient power infrastructure. Project milestones have been devised to address the fundamental technical issues in support of protection of large power transformer against EMP threats. More specifically, this project included parallel research tasks focused on the following topics: analysis of EMP-induced, fast-transient, current and voltages on a variety of power line configurations and EMP impact scenarios, detailed characterization of EMP damage potential due to the voltage surge, from the impact on the power line, to the transformer windings, GMD and EMP slow transients and impact from harmonics generation and reactive power flow on a complex grid layout, and identification of risk mitigation paths, with emphasis on GIC damage prevention for large power transformers, and on impact protection options from a grid stability perspective.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electromagnetic Prediction and Propagation

An electromagnetic finite volume forward solver is implemented to create a suite of forward models that provide the expected response for an air-filled buried structure constructed of concrete and rebar. Model parameters considered are the conductivities and thicknesses of a two-layer subsurface and the nature of VLF plane wave source. By building this suite of models, the results can be packaged into a data set that is both easily callable and requires minimal storage. More importantly, the user is relieved of the time required to manually execute a large number of models. Instead the results are already provided along with an interpolation tool for immediately data access. This document is written in compliance the LDRD reporting requirements for a close-out report on Project 180848.

42 ENGINEERING↗

Localized Electromagnetic Probing for Failure Analysis in Noisy Environments

Local electromagnetic probing was developed to allow investigation of a variety of devices in noisy electrical environments. The quality and applicability of this technique was assessed during this one year LDRD. To obtain details about the experimental setup, the devices imaged, and the experimental details, please refer to the classified report from the project manager, Will Zortman, or the NSP IA lead, Kristina Czuchlewski.

42 ENGINEERING↗

High Momentum Transfer Nucleon Elastic Electromagnetic Form Factor Measurements Using Super BigBite Spectrometer at Jefferson Lab

The nucleons - protons and neutrons - are the basic building blocks of atomic nuclei. We now know that the nucleon consists of fundamental particles called quarks and gluons. The quarks interact with each other by exchanging gluons via the strong interaction. Understanding the quark-gluon structure of the nucleon, especially the confinement of quarks within the nucleon in its ground state, remains one of the main unsolved puzzles of particle physics. The nucleon electromagnetic form factors are directly related to the internal structure of the nucleon. A new generation of high precision experiments, GEp-V, GEn-II, GEn-RP, and GMn, measuring the ground state nucleon space-like electro-magnetic form factor at high momentum transfer is underway at Jefferson Lab experimental Hall-A as part of the Super Bigbite Spectrometer (SBS) program. This series of experiments will provide a new level of understanding of the nucleon structure. These experiments are highly demanding due to the extremely fast drop off of the elastic cross section with the increasing four-momentum transfer squared(Q2). This thesis provides an overview of the SBS physics program and reports on the extensive R&D program carried out to achieve the high rate running conditions essential for carrying out the SBS experiments. SBS will provide an intermediate solid angle of approximately 35 msr, which is significantly larger than the solid angle of other dipole based spectrometers at Jefferson lab. Of course, there are much larger acceptance spectrometers at Jefferson Lab, CLAS12 for example. What is special about SBS is that it provides a sizable acceptance while operating at the highest possible luminosity at Jefferson Lab. With this combination of medium acceptance and the highest available luminosity, SBS provides an unparalleled opportunity to explore the nucleon in its ground state with unprecedented resolution. The relatively large acceptance of SBS is achieved by using a large gap dipole magnet and placing it close to the target. An unavoidable consequence of this is that the SBS GEM trackers and other detectors have a clear line-of-sight view of the target and a portion of the beam-line. As a result, the background hit rate in the SBS front GEM trackers is expected to be up to 500 kHz/cm2, over the entire active area of 6000 cm2. To the best of our knowledge, this extremely high rate over such a large area is unprecedented in any particle tracking system used anywhere in the world before. Correctly reconstructing the particle tracks of interest in this very high background environment is achieved by using especially adapted high rate techniques at every step of the tracking process: optimizing the GEM module and tracker design at the hardware level, using high bandwidth electronics and real time Field Programmable Gate Array (FPGA) based background suppression techniques at the Data Acquisition (DAQ) level, and developing highly specialized tracking algorithms to pick out the signal hits from among the vast amount of background hits. In order to ensure a smooth start and running of the SBS experiments, it is extremely crucial that these techniques are developed, implemented, and tested under realistic conditions well before the actual start of the SBS experimental program. A detailed Geant4 simulation of the experiment was combined with a digitization package to generate the detector level pseudodata similar to what is expected in the actual experiments. The digitization procedures were calibrated against actual GEM data from cosmic-ray runs, X-ray tests, beam test runs in experimental Hall-A, and the PRad experiment in Hall B. Then, optimized tracking algorithms were developed and implemented in an analysis program used to analyze these pseudo-data and to extract expected high-level parameters. These extracted quantities were then compared with the input parameters from the simulation to verify and determine the performance characteristics for the SBS tracker. From this work, a final tracking efficiency of 69% at 25% occupancy was achieved, with the required reconstruction accuracy, for the GMn experiment, the first experiment in the SBS program, with background level at 100 kHz/cm2. These demonstrated parameters are adequate for the successful running of not only the GMn experiment but as well as for GEn-RP and GEn-II experiments, the second and third experiments in the program. This work builds the solid ground to further improve the tracking performance for these experiments and achieve similar conditions for the running of the GEp-V experiment, the most demanding experiment in the SBS program, with an expected background level at 500 kHz/cm2.

Di, Danning↗

Substation Configuration Survey for Electromagnetic Coupling Analysis

Impacts of a high-altitude electromagnetic pulse (HEMP) on the power grid are a growing concern due to the increased reliance on the power grid. A critical area of research is quantifying power system equipment response to HEMP since this is not known in general. Substation site surveys were performed at seven high voltage substations across the United States to gather substation layout and construction details pertinent to HEMP coupling calculations and component vulnerability assessments. The primary objective for the survey was to gather information on cable layouts and cable construction within substations. Additional information was also gathered on equipment present within the substations and control house layouts. This report provides information gathered from the substation surveys.

24 POWER TRANSMISSION AND DISTRIBUTION↗

2020 State of the Science Report, Chapter 5: Risk to Animals from Electromagnetic Fields Emitted by Electric Cables and Marine Renewable Energy Devices

Interest in the potential effects of anthropogenic electromagnetic fields (EMFs) within the marine environment has increased in recent years, in part as a result of advanced knowledge gained from conducting dedicated research studies. To understand and interpret the potential environmental interactions of marine renewable energy (MRE)-related EMF emissions, it is necessary to consider the source of the EMFs and address the source within the context of the knowledge about the electro- and magneto-sensitivity of marine species. https://tethys.pnnl.gov/publications/state-of-the-science-2020-chapter-5-electromagnetic-fields

54 ENVIRONMENTAL SCIENCES↗

Prediction of Circuit Response to an Electromagnetic Environment (ASC IC FY2020 Milestone 7179)

This report covers the work performed in support of the ASC Integrated Codes FY20 Milestone 7179. For the Milestone, Sandia's Xyce analog circuit simulator was enhanced to enable a loose coupling to Sandia's EIGER electromagnetic (EM) simulation tool. A device was added to Xyce that takes as its input network parameters (representing the impedance response) and short-circuit current induced in a wire or other element, as calculated by an EM simulator such as EIGER. Simulations were performed in EIGER and in Xyce (using Harmonic Balance analysis) for a variety of linear and nonlinear circuit problems, including various op amp circuits. Results of those simulations are presented and future work is also discussed.

42 ENGINEERING↗

High Fidelity Interface Modeling to Enable Enhanced Electromagnetics ModSim Capabilities

Years of work by 1350 and others has shown that the phenomenology behind EM penetration of joints and seams is a major driver in the shielding effectiveness of ND systems. Via analysis of a canonical cylindrical geometry and comparison against experimental data, we will provide evidence supporting the theory that proper treatment of contact phenomenology including joint deformation, asperity-induced contact impedance, and appropriate treatment of machining tolerance values is required to match electromagnetics modeling and simulation results to experimental data.

36 MATERIALS SCIENCE↗

Early-Time (E1) High-Altitude Electromagnetic Pulse Effects on Trip Coils

A High-Altitude Electromagnetic Pulse (HEMP) is a potential threat to the power grid. HEMP can couple to transmission lines and cables, causing significant overvoltages which can be harmful to line connected equipment. The effects of overvoltages on various types of power systems components need to be understood. HEMP effects on trip coils were tested and presented in this report. A high voltage pulser was built to replicate the induced voltage waveform from a HEMP. The pulser was used to test breaker trip coils with increasing pulse magnitudes ranging from 20 kV to 80 kV. The State-of-Health of each trip coils was measured via mechanical operation and impedance measurements before and after each insult to identify any damage or degradation to the trip coils. Dielectric breakdown was observed at the conductor leads during testing, causing the HEMP insult to be diverted to the grounded casing. However, the dielectric breakdown did not cause interference with regular device operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sandia Electromagnetic Environment Simulator Facilities

Sandia National Laboratories’ (Sandia’s) Electrical Sciences Group (1350) provides a spectrum of solutions for electromagnetic (EM) environment effects on electrical systems to advance physical understanding including experiments, analytical and numerical model development leveraging first-principles physics, and high-performance computational modeling and simulation (M&S). The six departments in the Electrical Sciences Group provide analysis, design guidance, and experiments in support of nuclear weapons qualification in normal, abnormal, and hostile environments, as well as research and development for advanced electrical systems that can operate through these environments. This document is intended to provide a quick summary of Sandia’s EM experimental facilities, most of which provide unique national capabilities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Early-Time (E1) High-Altitude Electromagnetic Pulse Effects on Transient Voltage Surge Suppressors

Determining the effectiveness of surge and pulse protection devices in the United States power grid against effects of a High-Altitude Electromagnetic Pulse (HEMP) is crucial in determining the present state of grid resilience. Transient Voltage Surge Suppressors (TVSS) are used to protect loads in substations from transient overvoltages. Designed to mitigate the effects of lightning, their response to a HEMP event is unknown and was determined. TVSSs were tested in two unique configurations using a pulser that generates pulses in the tens of nanoseconds scale to determine their protective capability as well as to determine their self-resilience against HEMP pulses. Testing concluded that TVSS devices adequately protect against microsecond scale pulses like lightning but do not protect against pulses resembling HEMP events. It suggests that TVSS devices should not be relied upon to mitigate the effects of HEMP pulses.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Suitability of Altair FEKO's Computational Electromagnetic Techniques for Tree Model Scattering and Penetration at Ku-band

Foliage penetration (FOPEN) radar at lower frequencies (VHF, UHF) is a well-studied area with many contributions. However, there is growing interest in using higher Ku-band frequencies (12-18 GHz) for FOPEN. Specifically, the reduced wavelength sizes provide some key saliencies for developing more optimized detection solutions. The disadvantage is that exploiting Ku-band for FOPEN is complicated because higher frequencies have pronounced scattering effects due to their smaller wavelengths. A methodology h as been developed to model and simulate FOPEN problems that characterize the phenomenology of Ku-band electromagnetic ( EM ) wave transmissions through moderate foliage. The details of this research (i.e. the realistic tree models, simulation setup and results) are documented in multiple reports. The main focus of this report is to describe the preliminary validation and verification of Altair FEKO, the computational EM (CEM) software used for this research, as well as present a simplified symmetrical tree model and an introductory CAD tree model.

42 ENGINEERING↗

Literature Review of Electromagnetic Pulse (EMP) and Geomagnetic Disturbance (GMD) Effects on Oil and Gas Pipeline Systems

This document summarizes the findings of a review of published literature regarding the potential impacts of electromagnetic pulse (EMP) and geomagnetic disturbance (GMD) phenomena on oil and gas pipeline systems. The impacts of telluric currents on pipelines and their associated cathodic protection systems has been well studied. The existing literature describes implications for corrosion protection system design and monitoring to mitigate these impacts. Effects of an EMP on pipelines is not a thoroughly explored subject. Most directly related articles only present theoretical models and approaches rather than specific analyses and in-field testing. Literature on SCADA components and EMP is similarly sparse and the existing articles show a variety of impacts to control system components that range from upset and damage to no effect. The limited research and the range of observed impacts for the research that has been published suggests the need for additional work on GMD and EMP and natural gas SCADA components.

02 PETROLEUM↗