Search NASA⌕ Search

SEARCH · Search NASA

Results for “Excel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Robust metal-ceramic coaxial cable sensors for distributed temperature monitoring in fossil energy power systems

The project aims to develop a new type of low cost, robust metal-ceramic coaxial cable (MCCC) Fabry-Pérot interferometer (FPI) sensor and demonstrate the capability of cascading a series of FPI sensing points in a single MCCC for real-time distributed monitoring of temperature up to 1000°C. The technical accomplishments of this project include: (i) development of metal and ceramic materials for fabricating the MCCC suitable for use in high temperature (up to 1000oC) fossil fuel, (ii) design, construction and test of single point MCCC-FPI sensors for high temperature measurement at deviation within ±2.7%, (iv) demonstration of the MCCC-FPI sensors for real-time distributed temperature measurement with desired sensitivity, spatial resolution, stability, and response speed that are important to practical applications, and (v) development of a novel MCCC-FPI sensor platform for measuring high frequency dielectric constants for solids and liquids as function of temperature. Single point MCCC-FPI sensors are fabricated based on the FPI parameters, including the relationship between reflector width and reflectance as well as the inter-reflector distance for a FPI, estimated by model calculations. MCCC-FPI sensors have been made using insulators of packed ceramic powders, ceramic tubes, and air or inert gases; outer conductors of various metal tubes; inner conductors of wires of the same metal materials as the tubes used; and reflectors of dense ceramic discs, casted ceramic discs and air gaps. The insulator, conductor and reflector materials are investigated for their thermal, chemical, and structural stabilities under temperatures up to 1000°C in simulated coal-derived syngas. Based on the experimental findings, alumina tube and discs, and stainless steel tube and wire are selected for reflector, insulator and outer and inner conductors, respectively. Air or inert gases are found to be useful for reflectors (in the form of narrow groves) or insulators (in the form of empty chamber cavity between ceramic discs) in construction of MCCC-FPI sensors. Single point MCCC-FPI sensors have been fabricated using stainless steel as conductors, dense α-alumina tubes as dielectric insulators, and two air gaps in the insulator as reflectors. The MCCC-FPI sensor with air gap reflectors has been demonstrated for measuring temperature between 200 and 500°C using microwave as sensing signal in a frequency range of 2 – 8 GHz. The temperature measurement is achieved by monitoring the frequency shift (Δƒ) of a selected resonant peak of the microwave interferogram reflected from the pair of air gap reflectors. The MCCC-FPI sensor exhibited excellent linear temperature-dependence for Δƒ, good accuracy (deviation ±2.7%), and reasonable response speed (<180 s for stabilization). Thermal drifting of the sensing signal was also rather minimal for the MCCC-FPI sensors after operating for more than one week at around 500oC. MCCC-FPI sensors with each containing 2 or 3 pairs of reflectors (i.e. 2 or 3 FPIs in a single cable) have been fabricated and demonstrated for distributed temperature measurement between 250 and 550°C in a microwave frequency range of 3-6 GHz. The measurement is achieved by monitoring the frequency shift of a selected resonant peak of the reflected microwave interferogram, which is obtained by the join-time-domain signal processing method. The results demonstrate that the FPI sensing points in both the three-point and two-point MCCC sensors can measure distributed high temperature with good reproducibility and consistency in multiple runs of measurement tests. The sensor signal displays excellent linear dependence between temperature and the corresponding frequency shift. The 2-point and 3-point MCCC-FPI sensors also exhibit fast response to environmental temperature changes. A three-point MCCC-FPI sensor has been further examined for temperature measurement up to 1000°C for multiple heating-cooling cycles and the results prove that the sensor is suitable for distributed temperature measurement up to 1000°C. MCCC-FPI sensors with more than 4 FPIs point in a single line are made in two structures: the first uses alumina tube as insulation and air gaps as reflectors; and the second uses air chamber as insulation and complete circular alumina discs (2 mm-thick) as reflectors. MCCC-FPIs in neither of the two structures are able to exceed four FPIs in a cable because the reflections from the FPIs are too strong for the microwave to transmit through >4 FPIs over a long distance. Specially shaped alumina discs made by removing parts of the circular discs are found to decrease the microwave reflectance because of reduced reflection areas. However, the smallest reflectance (in terms of percentage of the incident signal) obtained in this work is as high as 7.5%, which is still too large to construct more than 10 FPIs in a single MCCC. Nevertheless, the feasibility of the proposed multipoint MCCC-FPI has been demonstrated using air insulation and 2 mm-thick low-ε r Teflon discs as reflectors on a 2 m-long cable containing 10 FPIs (with reflectance <5% on each FPI). These results indicate that the contrast of dielectric constant between the insulation and reflector has a more significant impact on the reflectance. Thus, future research efforts should also be directed to developing ceramic materials (dense or porous) with low dielectric constant values which, when used as insulation or reflector, can realize large numbers of FPIs in a single cable over a long distance. To assist the development of high temperature dielectric materials, a novel MCCC-FPI sensor platform is developed and successfully demonstrated for measuring high frequency dielectric constants for fluids, packed dielectric solids, and ceramic tube materials and determining ε r dependencies on temperature and chemical composition, etc..

36 MATERIALS SCIENCE↗

Summary of Expansions, Updates, and Results in GREET 2017 Suite of Models

This report provides a technical summary of the expansions and updates to the 2017 release of Argonne National Laboratory’s Greenhouse Gases, Regulated Emissions, and Energy Use in Transportation (GREET®) model, including references and links to key technical documents related to these expansions and updates. The GREET 2017 release includes an updated version of the GREET1 (the fuel-cycle GREET model) and GREET2 (the vehicle-cycle GREET model), both in the Microsoft Excel platform and in the GREET.net modeling platform. Figure 1 shows the structure of the GREET Excel modeling platform. The .net platform integrates all GREET modules together seamlessly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Highly Stable Anion Exchange Membranes for High-Voltage Redox-Flow Batteries

In this work, multiple polymer backbones were screened for oxidation resistance and multiple chemistries were explored for tethering tris(2,4,6-trimethylphenyl)phosphonium (9MeTTP + ) to the selected polymer backbones. A new tethering strategy through brominated 9MeTTP+ cation was developed and used to obtain the desired 9MeTTP + -functionalized polysulfone (PSf) and hexafluoro polybenzimidazole (F 6 PBI) polymer. The crosslinked 9MeTTP+-functionalized hexafluoro polybenzimidazole (9MeTTP-F 6 PBI) polymer demonstrated excellent oxidation stability that met the go-no-go milestone of the first year. However, large-scale bromination inevitably involved multi-bromination products, which led to polymer crosslinking in the next tethering. A new synthesis strategy with diiodobutane as linker was developed to overcome the crosslinking problem. The prepared 9MeTTP + -F 6 PBI membrane without crosslinking showed only 3.58% water uptake and less than 1 mS/cm OH - conductivity in water at 20°C, possibly due to the hydrophobic 9MeTTP + cation. In order to improve the conductivity, hydrophilic tris(2,4,6-trimethoxylphenyl)phosphonium (9MeOTTP+) cation was tethered to an F 6 PBI backbone, and a 9MeOTTP + -F 6 PBI PTFE reinforced membrane was prepared with 17.4% water uptake to increase the mechanical strength and durability in cerium (IV) solution. A 9MeOTTP+-F 6 PBI PTFE reinforced membrane had less than 20% conductivity loss during an accelerated stability test in 0.5 M cerium (IV) and 1.3 M HClO 4 at 55°C for 100 hours. Moreover, a 9MeOTTP + -F 6 PBI PTFE reinforced membrane had more than double the lifetime of commercial FAS-30 and FAB-PK-130 AEMs during an accelerated stability test in 0.5 M cerium (IV) and 1.3 M HClO 4 at 55°C. Low area specific resistance (ASR) of a 9MeOTTP + -F 6 PBI PTFE reinforced membrane in the sulfuric acid system was also achieved due to the high acid doping ability of the polymer structure. The cationic 9MeOTTP + -F 6 PBI PTFE reinforced membrane shows a cerium (IV) permeability that is 27-fold lower than that of Nafion 212. Excellent voltage and energy efficiencies with a 9MeOTTP + -F 6 PBI PTFE reinforced membrane were demonstrated in an all-vanadium redox flow battery (VRFB).

25 ENERGY STORAGE↗

Assessment of CO 2 Storage Resources in Depleted Oil and Gas Fields in the Ship Shoal Area, Gulf of Mexico

The Gulf of Mexico is one of the most important regions in the United States for energy resources and infrastructure. Gulf of Mexico federal offshore oil and gas production accounts for 17% of total U.S. crude oil production and 5% of total U.S. gas production (EIA Gulf of Mexico Fact Sheet). This region presents an excellent combination of high need and significant opportunity for large scale geologic storage of CO 2 . The Ship Shoal Area is located about 20 miles offshore Louisiana within the Gulf Coast federal waters. Miocene and Pliocene sediments in the Ship Shoal Area are proven to provide excellent and secure traps for oil and gas. The Ship Shoal Area contains a large number of depleted oil and gas fields either currently abandoned, or planned for abandonment by 2025, which may provide very significant potential CO 2 storage capacity. GeoMechanics Technologies conducted a comprehensive research project to better characterize Neogene sediments in the Ship Shoal Area for high volume CO 2 storage. The data generated from literature, well data, well log, and formation evaluation were input into Rockwork 16 geologic software to create a detailed geologic model for the Ship Shoal study area. The geologic grids were then fed into TOUGH2, the gas migration model software and FLAC 3D, the geomechanical model software. The fluid flow modeling for both the Miocene and Pliocene simulation from both Block 107 and Block 84 indicated that Pliocene and Miocene are a good reservoir for the CO 2 sequestration. Thirty years of CO 2 injection (at a rate of 1 million metric tons CO 2 per year) and 30 years of observation simulations were run with the fluid flow modeling. The 3D geomechanical modeling for Ship Shoal Block 107 and Block 84 were developed to evaluate induced surface deformation and potential fault reactivation after 30 years CO 2 injection at base of Pliocene and at upper Miocene injection locations. Evaluation results indicate low to no risks for fault slips or fault reactivation. Twelve well bores and 76 well bores for Ship Shoal Blocks 84 and 107 respectively were reviewed for their cement history. Most wells (57 out of 76 and 7 out of 12 wells in Ship Shoal Block 107 and 84 respectively) have good integrity. Nineteen and 5 wells (in Ship Shoal Block 107 and 84 respectively) with no top plug, incomplete cement or Plug and Abandonment information are given yellow cautionary indicators. These cautionary wells may provide leakage paths of CO 2 through the well bores to the USDWs. Using our Quantitative Risk & Decision Analysis Tool (QRDAT) for caprock integrity evaluation, we compared Ship Shoal’s risk to that of In Salah, Sleipner, Kevin Dome, Loudon, Illinois Industrial CCS and Wilmington Graben. We found the risk at the Ship Shoal Blocks 84 and 107 fields are similar to the known CO 2 active sequestration sites, but lower than the Wilmington Graben turbidities offshore California studied site. The risk of natural seismicity in the Gulf of Mexico is relatively low. Geomechanics Technologies has documented the top 25 CO 2 emission sources within the close proximity of the Ship Shoal Block 84 and 107 fields. All the offshore and onshore pipelines have been digitized and can be viewed in an interactive website (http://www.geomechanicstech.com/shipshoal.html). We also performed a feasibility study on the potential for converting existing oil or gas pipelines for CO 2 transport. There are abandoned, idled and retired onshore and offshore pipelines. However, there is no standard specification for maximum pipeline pressures needed for CO 2 transport. It is a function of design, materials, and testing provided; thus it will be the responsibility of the pipeline operator to correctly determine, maintain and operate within the limits of the pipelines. There are a few transit corridors extending from onshore Louisiana (Cailou Bay) to offshore trunk-lines. The cost for constructing a pipeline has increased about 46% from 2015 to an average cost of $5,064,046 per mile in 2016. We use the NETL CO 2 storage resource mass estimate to calculate the potential resources for Ship Shoal Block 84 and 107 fields using the depleted oil and gas reservoir volume and sand volume generated from our geologic modeling. The estimated storage resource results are greater when using the sand volumes derived through geologic modeling than the oil and gas reservoir data. The difference is due to the depleted oil and gas reservoir information not accounting for the water-flooded sand located below the oil/gas-water contact or unproductive sand units. Resource calculation using the sand volume obtained through geologic modeling overestimate the storage capacity as the model accounts for all sand within the formation, not just the interconnected sand.

02 PETROLEUM↗

Institutional Transformation (IX) 2.5 Building Module Help Manual

The Institutional Transformation (IX) building module is a software tool developed at Sandia National Laboratories to evaluate energy conservation measures (ECMs) on hundreds of DOE-2 building energy models simultaneously. In IX, ECMs can be designed through parameterizing DOE-2 building models and doing further processing via visual basic for applications subroutines. IX provides the functionality to handle multiple building models for different years, which enables incrementally changing a site of hundreds of buildings over time. It also enables evaluation of the effects of changing climate, comparisons between data and modeling results, and energy use of centralized utility buildings (CUBs). IX consists of a Microsoft Excel® user interface, Microsoft Access® database, and Microsoft Excel® CUB build utility whose functionalities are described in detail in this report. In addition to descriptions of the user interfaces, descriptions of every ECM already designed in IX is included.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Theoretical Investigations of Nano and Bio Structures

The PI was supported by the DOE grant entitled “Theoretical Investigations of Nano and Bio Structures,” 3/1/13-2/28/17, $440,000, and a one-year no cost extension, 3/1/17-2/28/18. Its main emphasis was on nonequilibrium electron transport and novel nanoscale materials and devices, such as graphene nanoribbons, nanotube-based sensors, nanocircuits able to detect DNA replication, and DNA nanowires. We have also made major enhancements to our RMG suite of electronic structure codes, leading to much increased scalability, excellent parallelization of across both CPU and GPU nodes, and cleaner, refactored code base. For example, RMG performs excellently on Summit, DOE’s flagship supercomputer and the fastest supercomputer in the world. It scales to over 100,000 CPU cores and 20,000 GPUs, and can use multiple GPUs per node. It performs 80x faster per node than on DOE’s previous flagship supercomputer, Titan. This is the final report for grant DE-FG02-98ER45685.

36 MATERIALS SCIENCE↗

Benchmark Analysis of the HTR-10 with the MAMMOTH Reactor Physics Application

This report documents a set of benchmarks used to validate the Serpent and MAMMOTH neutron transport models of the HTR-10 reactor developed at Idaho National Laboratory. The high-fidelity Serpent Monte Carlo models of the HTR-10 critical and full core configurations include both random, discrete distributions of TRISO particles in the pebbles and random, discrete pebble distributions in the pebble bed core. The Serpent results agree very well with the critical and control rod worth measurements provided in the International Re- actor Physics Experiment Evaluation Project (IRPhEP) report if the ENDF/B-VII.r1 data- set is used. These Serpent models are subsequently used to prepare cross sections and flux tallies in a 10 coarse energy group structure for the MAMMOTH Reactor Physics MOOSE- based application. We find that MAMMOTH can reproduce the Monte Carlo solution for the HTR-10 reactor by using the PJFNK-SPH equivalence method. In all cases studied, the MAMMOTH results are within 120 pcm of the Monte Carlo reference calculation and the maximum errors in neutron absorption and generation rates are within 0.536% and 0.215% from the reference calculation, respectively. A set of benchmark exercises from the International Atomic Energy Agency (IAEA) HTR-10 benchmark in IAEA-TECDOC-1382 were conducted including parts B1 (critical), B2 (temperature coefficient) and B3 (control rod worth). The results we obtain for the critical core are in excellent agreement with the expected value and we confirm that with ENDF/B-VII.r1 data we match the critical eigen- value keff=1 to within 100 pcm. Our temperature coefficient calculation is consistent with the VSOP results generated by the German participants. The Chinese and South African VSOP models produce lower temperature coefficients, a fact that was noted in the original IAEA benchmark, but for which no explanation was provided. Both a full and single control rod worth calculations with Serpent and MAMMOTH agree well with the results from the IAEA benchmark. Finally, and most importantly, this work demonstrates that MAM- MOTH can recover the Monte Carlo high-fidelity solutions to an excellent accuracy using the PJFNK-SPH method. This sets the stage for the ultimate goal of using MAMMOTH in transient, multi-physics scenarios where correction of the cross sections is obtained for steady-state conditions and then used in the transient scenario for which no Monte-Carlo solution is available.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Commercial Building Technology Demonstration (Final Scientific/Technical Report)

The background for this project was a unique and innovative concept that had been proposed and demonstrated by enVerid Systems, reducing the energy consumption in HVAC systems in commercial and public buildings by up to 50% at peak loads. The concept involves selective scrubbing of gas contaminants from indoor air as a practical substitute for outside air ventilation, the latter being the conventional practice today. This scrubbing enables recycling of most of the indoor air and significantly decreasing the amount of outside air, resulting in a reduced HVAC load and commensurate energy savings for the facility. Key to our approach is low cost scrubbing of all gas contaminants from indoor air using novel, efficient and regenerable sorbent materials. The total solution, labeled HLR (HVAC Load Reduction) is implemented by means of compact modules that can be retrofitted onto virtually any building, and utilizes novel sorbents that have been developed and brought to scale production by enVerid. Although the technology had been deployed and demonstrated, the US commercial building and HVAC markets, famously conservative with respect to innovation and new technologies, had yet to embrace the idea or the product. The overarching goal of the project was to help overcome market hesitancy and enable widespread adoption, by creating a critical mass of success stories across different regions and building types, all under oversight and verification of the DOE and NREL, to ensure credibility and accuracy. The project, overall, was a resounding success. Several installations were deployed and tested comprehensively for the impact on both energy consumption and indoor air quality, and results were not only excellent, but quantitatively in line with expectations. A total number of eight (8) installations were attempted, with 2 aborted due to building issues. Of the six successful installations, however, complete M&V was performed by NREL on 2 (Miami and NYC) and partial analysis on a third site (ArcBest), and these three, along with their results, were therefore presented from a financial and reporting standpoint. Although the number of case studies fell short of the original target of 10, we nevertheless had excellent demonstrations in vastly different climate zones: Southeast, Northeast and Midwest, and in very different building types. This included a modern high-rise office building in New York City and a University Campus health center in Miami, and a mid-rise high-density office in Arkansas. The cooling load reduction was shown to be significant, averaging 37% during the final cooling season in the Miami site. In the NYC site, the cooling energy savings were generally less, at around 12%, as expected. While this is a lower number for average/total savings, two comments are important to note: (i) the outside airflow (OA) reduction was not consistent during the data collection period, at least in part understating the attainable savings through incorrect measurement of the “high energy” reference state; and (ii) the peak impact in NYC is almost certainly as high as Miami, with critical ramifications for peak load reduction and equipment downsizing ability. Importantly, the measured energy savings in all locations were related to the outdoor climate conditions and the actual achievable reduction in outside air, very much in line with models and calculations; this leaves us with increased confidence in our understanding of the interaction between the technology and the building, and our ability to project the impact of this innovation in the future, through broad adoption. Simply put: the energy savings and load reduction impact of the HLR solution has been confirmed quantitatively. The results also confirmed the air quality objective. This may be even more significant, in that air quality is more complex and harder to measure and quantify, and the performance of the HLR as an air scrubber is the linchpin of the entire solution. In all sites, indoor air quality met or exceeded the required parameters, in terms of achieving the target (low) levels of indoor pollutants. Furthermore, the concentrations of outdoor sourced pollutants were markedly lower, as expected, mostly due to the reduction in outside air intake although in part also due to the scrubbing. The success was not immediate nor easy, and early challenges with the systems, especially (but not only) around controls and communication, caused delays in commissioning and undermined some of our M&V schedules. The good news is no fundamental issues were encountered and the number of such glitches was declining quickly by the end of the project. Other challenges had to do with coordinating the control of the building OA dampers, which the HLR needs to have in order to deliver the load reduction, but which the facility manager controls regularly and independently. This is not necessarily a problem for normal HLR operation but interferes with accurate M&V, where switching OA settings back and forth on a precise timetable is essential for clean data. The project provided valuable experience in retrofitting buildings that had been originally designed to operate with less recirculation and more outside air, and some key learnings related to the cyclical regeneration of the sorbents in the operational environment of the building. Some of these learnings gave already been incorporated into ongoing improvements in the design of the HLR module as well as the software that is used to control its operation. The cost and time of retrofit installations is much better understood; so is the test and balance procedure of the building that determines the available range of outside air reduction, which in turn determines the amount of load reduced. We had also implemented at least one annual cycle of sorbent cartridge replacement in the field, after which we tested the used sorbent to assess the rate of degradation of sorbent potency – an important factor affecting the long-term economics of HLR deployments. A notable shortfall of the project, other than the fact that the number of sites was below target, was that we had not (yet) completed testing to measure and verify (M&V) the winter energy savings. This is primarily due to late start on the NYC sites (Miami does not portend any heating savings associated with reduced outside air), combined with the issues of OA damper control. It is by no means suggested that such savings cannot be captured, only that the M&V with respect to winter in NYC has been incomplete. The value of this project and its interest to the general public are hard to overstate. The case studies created from Miami and especially from NYC have, without a doubt, opened up the interest of the broad HVAC industry to HLR in the past year. Major manufacturer reps have signed up to represent and promote the product, and dozens of top tier engineering consultants have introduced HLR as a base of design in upcoming construction and renovation projects – precisely the overarching goal of this project. These would not have happened without the highly visible installation in NYC and its ultimately satisfied customer. Furthermore, the DOE itself issued a report in late 2017 analyzing hundreds of candidate technologies for reducing energy consumption in HVAC; remarkably, the budding HLR solution ranked among the top 3(!); no doubt, its status as a viable and significant contender on this list is informed by the success of these demonstrations. And furthermore, in the wake of these demos, several major energy utilities, led by ConEdison in NYC, have endorsed the HLR solution and now routinely provide substantial cash rebates for customers choosing to incorporate the HLR in their buildings and reap the benefit of the reduced peak load as well as reduced cumulative energy demand. Last but not least, in January of 2019, as this report was being written, the HLR module won the AHR Expo Innovation Award for Green Buildings and, remarkably, the prestigious and only Product of the Year 2019, being selected by an independent professional panel of judges from AHR and ASHRAE. Given the confirmation of the enormous energy saving potential of HLR in widescale deployment, as well as ancillary but significant benefits in terms of equipment downsizing and indoor air quality, the benefit of this effort to the public speaks for itself. Accelerating adoption of HLR, without dependence on subsidies and driven by the private sector, is well under way. There is still much work to be done in terms of educating the HVAC and construction ecosystems and improving the product’s robustness and simplicity, to further facilitate the adoption of this technology and the capture of its potential value. But the American public will greatly benefit both directly and indirectly in the immediate future and beyond.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Low Cost Rare Earth Element (REE) Recovery from Acid Mine Drainage Sludge

In this research effort, three core technologies were evaluated for REE concentration and recovery: (1) Nanofiltration (NF), (2) Electrically conductive membranes for induced rare earth oxide (REO) precipitation, (3) dendrimer-based sorbents for REE capture. The NF showed excellent selectivity between REE components and monovalent ionic salts such as K and Na. For all AMD samples, iron selectivity is a critical challenge since it is the highest concentration bulk constituent. Membrane electrodeposition approach shows promise for scandium and cerium recovery, but iron selectivity not observed. This technology may therefore be more appropriate REE recovery technology for non-iron rich streams such as coal ash. P-dendrimer derived sorbent shows promise for aqueous application, with high sorption capacity for iron demonstrated, and pH tunable selectivity against REE sorption. Although in some cases excellent selectivity for REE was observed, the REE concentrations from all four AMD sites was low enough that the 2wt% final goal was not attained.

01 COAL, LIGNITE, AND PEAT↗

Adiabatic Cooling System Spreadsheet Model for sCO 2

The attached cost and performance spreadsheet model is for an adiabatic cooling system, one of four cooling system models developed for use in optimizing indirectly-heated supercritical CO 2 (sCO 2 ) power cycles. Running the model requires that the user has REFPROP version 9 or below installed, as well as the Microsoft Excel REFPROP Add-In. Upon opening, use Excel’s Edit Links feature to link to the user’s installed REFPROP.xla or REFPROP.xlam file. For the spreadsheet model compatible with REFPROP version 10 and above, contact Nathan Weiland at nathan.weiland@netl.doe.gov. Technical documentation for the model can be found here: https://www.netl.doe.gov/energy-analysis/details?id=3199.

30 DIRECT ENERGY CONVERSION↗

Direct Dry Cooling System Spreadsheet Model for sCO 2

The attached cost and performance spreadsheet model is for a direct dry cooling system, one of four cooling system models developed for use in optimizing indirectly-heated supercritical CO 2 (sCO 2 ) power cycles. Running the model requires that the user has REFPROP version 9 or below installed, as well as the Microsoft Excel REFPROP Add-In. Upon opening, use Excel’s Edit Links feature to link to the user’s installed REFPROP.xla or REFPROP.xlam file. For the spreadsheet model compatible with REFPROP version 10 and above, contact Nathan Weiland at nathan.weiland@netl.doe.gov. Technical documentation for the model can be found here: https://www.netl.doe.gov/energy-analysis/details?id=3199.

30 DIRECT ENERGY CONVERSION↗

Indirect Dry Cooling System Spreadsheet Model for sCO2

The attached cost and performance spreadsheet model is for an indirect dry cooling system, one of four cooling system models developed for use in optimizing indirectly-heated supercritical CO2 (sCO2) power cycles. Running the model requires that the user has REFPROP version 9 or below installed, as well as the Microsoft Excel REFPROP Add-In. Upon opening, use Excel’s Edit Links feature to link to the user’s installed REFPROP.xla or REFPROP.xlam file. For the spreadsheet model compatible with REFPROP version 10 and above, contact Nathan Weiland at nathan.weiland@netl.doe.gov. Technical documentation for the model can be found here: https://www.netl.doe.gov/energy-analysis/details?id=3199.

30 DIRECT ENERGY CONVERSION↗

Wet Cooling Tower Cooling System Spreadsheet Model for sCO2

The attached cost and performance spreadsheet model is for a wet cooling tower system, one of four cooling system models developed for use in optimizing indirectly-heated supercritical CO2 (sCO2) power cycles. Running the model requires that the user has REFPROP version 9 or below installed, as well as the Microsoft Excel REFPROP Add-In. Upon opening, use Excel’s Edit Links feature to link to the user’s installed REFPROP.xla or REFPROP.xlam file. For the spreadsheet model compatible with REFPROP version 10 and above, contact Nathan Weiland at nathan.weiland@netl.doe.gov. Technical documentation for the model can be found here: https://www.netl.doe.gov/energy-analysis/details?id=3199.

30 DIRECT ENERGY CONVERSION↗

Pixel Array Germanium Detectors for Nuclear Physics (Final Technical Report)

The Department of Energy (DOE) Office of Nuclear Physics supports the development and maintenance of germanium gamma-ray detector arrays at national laboratories and universities. Germanium gamma-ray detectors provide state-of-the-art gamma-ray energy resolution, making them critical for gamma-ray and x-ray spectroscopy in Nuclear Physics. Furthermore, detector segmentation and charge-signal waveform processing enables 3-dimensional (3D) measurement of gamma-ray interaction locations needed for the highest-fidelity Nuclear Physics experiments. Attaining and maintaining excellent gamma-ray energy resolution depends largely on the naturally excellent charge-collection properties of germanium crystals. However, the optimal method for achieving the best practical 3D spatial resolution within the detector volume at high counting rates is less clear.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Los Alamos National Laboratory Hazardous Waste Facility Permit Community Relations Plan

The requirements of the Hazardous Waste Facility Permit are fulfilled through execution of LANL's fourth strategic goal: “Enabling mission delivery through next-generation facility, infrastructure, and operational excellence.” With input from our stakeholders, we will continue to fulfill those requirements and to improve our waste operations. In 2015, the Laboratory purpose statement focused waste management efforts by directing delivery of mission success through operational effectiveness and scientific excellence. This Plan advances that purpose through community involvement. In the process of achieving our national security mission, Los Alamos National Laboratory generates some hazardous and mixed waste. Hazardous waste is solid waste that is dangerous or potentially harmful to human health or the environment. Hazardous wastes can be liquids, solids, gases, or sludges. They can be discarded as commercial products, such as cleaning fluids or pesticides, or as the byproducts of operations. Specific substances are listed in 40 Code of Federal Regulations (CFR), Part 261: 40 CFR Part 261. Hazardous waste management activities are regulated by the U. S. Environmental Protection Agency and the New Mexico Environment Department (NMED) pursuant to New Mexico Hazardous Waste Act (HWA; Chapter 74, Article 4 NMSA 1978) and regulations under the Act. In 1989, NMED issued the Hazardous Waste Facility Permit (EPA ID Number NM0890010515-1) that established standards for the Laboratory to manage, store, and treat hazardous wastes on-site and to undertake the closure, post closure care, and cleanup as necessary, of permitted waste management units. On November 30, 2010, NMED renewed the Hazardous Waste Facility Permit (the Permit). In June 2020 the Permittees submitted a permit renewal application to the NMED for their review and approval. The Hazardous Waste Facility Permit Community Relations Plan (CRP) describes the scope of public involvement in the activities of the Permit. The CRP is specifically designed to facilitate the community outreach, engagement, and relations activities concerning the Laboratory’s Hazardous Waste Facility Permit and coordinates with but does not include public involvement for other Laboratory programs, initiatives, or environmental activities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cardinal: A Lower Length-scale Simulator for Fluoride Cooled High Temperature Reactors

The new DOE-NE “Center of Excellence for Thermal-fluids applications in Nuclear Energy” inaugurated in April 2018 considers and researches novel new solution strategies for historically challenging flow issues that still plague the current fleet of deployed Light Water Reactor (LWR) nuclear reactors as well as predicting various fluid flow and fluid related issues with advanced reactor technologies. Our advanced thermal-fluids research and development approach synergistically combines three natural, though overlapping, length and time scales in a hierarchal multi-scale approach to avoid the temptation and pitfalls of attempting to develop a single “solve all” algorithm for physical fluid flow problems that will span 109 in spatial and temporal scales. The demonstrate the multi-scale philosophy of the center we focus first on Fluoride Cooled High Temperature Reactors (FHRs), and in particular on the Berkeley’s PB-FHR design Mark-I design. The Fluoride salt cooled High temperature Reactor (FHR) is a class of advanced nuclear reactors that combine the robust coated particle fuel form from high temperature gas cooled reactors, direct reactor auxiliary cooling system (DRACS) passive decay removal of liquid metal fast reactors, and the transparent, high volumetric heat capacitance liquid fluoride salt working fluids - Flibe - from molten salt reactors. This combination of fuel and coolant enables FHRs to operate in a high-temperature low-pressure design space that has beneficial safety and economic implications. The PB-FHR reactor relies on a pebble bed approach and pebble bed reactors are in a sense the poster child for multiscale analysis. The lower length-scale simulator for pebble reactor cores comprises three physics: neutronics (OpenMC), thermal-fluids (Nek5000) and fuel performance (BISON). As part of center of excellence ongoing research efforts we have developed “Cardinal”, a new tool platform for lower length-scale simulation. Cardinal tightly couples all three physics and leverages advances in MOOSE such as the MultiApp system and the concept of MOOSE-wrapped Apps. Moreover it is designed from the ground-up to scale on massively parallel architectures and perform well on world-class super-computing architectures. In this report we describe the design of Cardinal and present a demo of the application of Cardinal to an FHR.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Proceedings of the 10th US/German Workshop on Salt Repository Research Design and Operation. Rev. 1

The 10th US/German Workshop on Salt Repository Research, Design, and Operation was hosted by RESPEC and South Dakota School of Mines & Technology, both located in the Black Hills of South Dakota. Over 60 registered participants representing Germany, United States, the Netherlands, and the United Kingdom availed themselves to excellent facilities on the School of Mines campus. As the 10th annual workshop, this occasion is a milestone of the modern era of collaboration between the US and Germany, which has extended to other countries with potential for radioactive waste disposal in salt. Thrust areas covered in the annual workshops are selected by participants and typically include elements of continuity from year to year. This year's themes included siting, modeling challenges, seal systems and materials, operational safety, and special topics. Two major breakout sessions addressed test sample conditioning and natural closure of salt openings. When the new-generation US/German workshops were conceived, one goal was to identify challenging issues related to salt repository sciences and then conduct open discussions in special breakout sessions. These timely sessions achieve the workshop paradigm and provide in-depth dialogue on important salt repository considerations. In many respects, general themes of these salt repository workshops reflect advances in the scientific basis for nuclear-waste disposal in salt formations and develop naturally as a consequence of unremitting attention largely as a result of the workshop commitment. Technical capabilities in the laboratory and field continue to improve in concert with accumulating experience. Because we are working together, mechanical deformation at the micro-scale can be interpreted at a large scale, which is fundamental to predictive modeling of salt repository evolution. This document records the Proceedings of the 2019 gathering of salt repository nations and has been compiled by RESPEC, demonstrating an adopted protocol in which the host organization creates that year's Proceedings. To assist with organization and compilation, individual chapters are summarized by volunteer subject-matter experts from the participatory audience; these contributors are recognized in the Acknowledgements. All formal presentations are included in this document, thus providing a resource for referencing and many excellent photographic images. Appendices include the agenda, list of participants, abstracts, and presentations. A primary purpose for recording workshop activities is to create and sustain an accessible record of salt repository research. These archives also illustrate transparent development of research areas each year.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An Update on Cardinal: Toward Full Core Pebble Simulations

The new DOE-NE Center of Excellence for Thermal-fluids applications in Nuclear Energy inaugurated in April 2018 considers and researches novel new solution strategies for historically challenging flow issues that still plague the current fleet of deployed Light Water nuclear Reactors (LWRs) as well as predicting various fluid flow and fluid related issues with advanced reactor technologies. Our advanced thermal-fluids research and development approach synergistically combines three natural, though overlapping, length and time scales in a hierarchal multi-scale approach to avoid the temptation and pitfalls of attempting to develop a single solve-all algorithm for physical fluid flow problems that will span nine orders of magnitude in spatial and temporal scales. To demonstrate the multi-scale philosophy of the center we focus on Fluoride Cooled High Temperature Reactors (FHRs), and in particular on the Berkley’s PB-FHR Mark-I design. The Fluoride salt cooled High temperature Reactor (FHR) is a class of advanced nuclear reactors that combine the robust coated particle fuel form from high temperature gas cooled reactors, direct reactor auxiliary cooling system (DRACS) passive decay removal of liquid metal fast reactors, and the transparent, high volumetric heat capacitance liquid Fluoride salt working fluids - such as Flibe - from molten salt reactors. This combination of fuel and coolant enables FHRs to operate in a high-temperature low-pressure design space that has beneficial safety and economic implications. The PB-FHR reactor relies on a pebble bed approach and pebble bed reactors are in a sense the poster child for multi-scale analysis. The lower length-scale simulator for pebble reactor cores comprises three physics: neutronics (OpenMC), thermal-fluids (Nek5000/NekRS) and fuel performance (BISON). As part of Center of Excellence ongoing research efforts we have developed Cardinal, a new tool platform for lower length-scale simulation. Cardinal tightly couples all three physics and leverages advances in MOOSE such as the MultiApp system and the concept of MOOSE-wrapped Apps. The present report provides an update on the development of Cardinal with an extension of Cardinal to GPUs. We also perform a first-of-a-kind demonstration simulation on Summit representing a 10x capability increase in terms of pebble count for Cardinal.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗