Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Performance Storage Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

European Regional Climate Zone Modeling of a Commercial Absorption Heat Pump Hot Water Heater

High efficiency gas-burning hot water heating takes advantage of a condensing heat exchanger to deliver improved combustion efficiency over a standard non-condensing configuration. The water heating is always lower than the gas heating value. In contrast, Gas Absorption Heat Pump (GAHP) hot water heating combines the efficiency of gas burning with the performance increase from a heat pump to offer significant gas energy savings. An ammonia-water system also has the advantage of zero Ozone Depletion Potential and low Global Warming Potential. In comparison with air source electric heat pumps, the absorption system can maintain higher coefficients of performance in colder climates. In this work, a GAHP commercial water heating system was compared to a condensing gas storage system for a range of locations and climate zones across Europe. The thermodynamic performance map of a single effect ammonia-water absorption system was used in a building energy modeling software that could also incorporate the changing ambient air temperature and water mains temperature for a specific location, as well as a full-service restaurant water draw pattern.

Sharma, Vishaldeep↗

Novel thermal energy storage component: Development, performance, and phase transition diagnosis

Thermal energy storage (TES) using phase change materials (PCMs) is a promising technology for capturing and storing excess thermal energy for later use. However, challenges such as poor heat transfer efficiency and a lack of modular, scalable designs have limited widespread adoption of TES in real-world applications. This study developed and evaluated modular brick-type and blade-type TES prototypes featuring an aluminum housing, an embedded serpentine coil for active or passive thermal exchange, and a cost-effective metal mesh to enhance PCM thermal conductivity. The blade-type TES achieved notable geometric efficiency, with a thickness-to-length ratio of 0.03 and a thickness-to-width ratio of 0.08, enabling highly compact and modular thermal storage suitable for space-constrained applications. The paper presents a detailed evaluation of the TES prototypes’ performance. The comparative analysis indicated that the TES prototypes provide a highly cost-effective, thermally optimized alternative for compact energy storage and load shifting. A novel diagnostic technique was also introduced: using a portable endoscope to capture real-time visualizations of PCM phase transitions inside the TES. This method provides critical insights into internal heat transfer mechanisms, identifies potential issues, and offers valuable support for optimizing the TES design and developing the control algorithm. Overall, the modular brick-type and blade-type TES designs demonstrated in this work provide a scalable, efficient, and economically viable solution for advancing TES across residential, commercial, and industrial sectors. The designs’ compact structure, enhanced thermal performance, and integrated diagnostic capabilities make them strong candidates for future deployment in energy-efficient systems.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

Active and Transfer Learning of High-Dimensional Neural Network Potentials for Transition Metals

Classical molecular dynamics (MD) simulations represent a very popular and powerful tool for materials modeling and design. The predictive power of MD hinges on the ability of the interatomic potential to capture the underlying physics and chemistry. There have been decades of seminal work on developing interatomic potentials, albeit with a focus predominantly on capturing the properties of bulk materials. Such physics-based models, while extensively deployed for predicting the dynamics and properties of nanoscale systems over the past two decades, tend to perform poorly in predicting nanoscale potential energy surfaces (PESs) when compared to high-fidelity first-principles calculations. These limitations stem from the lack of flexibility in such models, which rely on a predefined functional form. Machine learning (ML) models and approaches have emerged as a viable alternative to capture the diverse size-dependent cluster geometries, nanoscale dynamics, and the complex nanoscale PESs, without sacrificing the bulk properties. Here, in this study, we introduce an ML workflow that combines transfer and active learning strategies to develop high-dimensional neural networks (NNs) for capturing the cluster and bulk properties for several different transition metals with applications in catalysis, microelectronics, and energy storage, to name a few. Our NN first learns the bulk PES from the high-quality physics-based models in literature and subsequently augments this learning via retraining with a higher-fidelity first-principles training data set to concurrently capture both the nanoscale and bulk PES. Our workflow departs from status-quo in its ability to learn from a sparsely sampled data set that nonetheless covers a diverse range of cluster configurations from near-equilibrium to highly nonequilibrium as well as learning strategies that iteratively improve the fingerprinting depending on model fidelity. All the developed models are rigorously tested against an extensive first-principles data set of energies and forces of cluster configurations as well as several properties of bulk configurations for 10 different transition metals. Our approach is material agnostic and provides a methodology to transfer and build upon the learnings from decades of seminal work in molecular simulations on to a new generation of ML-trained potentials to accelerate materials discovery and design.

36 MATERIALS SCIENCE↗

Thermal cycling-driven microstructural changes of eutectic Al–Si phase change materials in SS304 containers revealed by multi-modal imaging

Aluminum-based Al–Si alloys are widely used as phase change materials (PCMs) in thermal energy storage (TES) systems owing to their high volumetric latent heat and superior thermal conductivity. However, their long-term reliability is limited by degradation processes that remain insufficiently understood. In this work, we employ a multimodal, correlative characterization framework to systematically resolve the degradation behavior of eutectic Al–Si PCMs in contact with SS304 containers under repeated thermal cycling. By integrating high-resolution electron microscopy, three-dimensional X-ray fluorescence (3D XRF) imaging, and differential scanning calorimetry (DSC), we directly link spatially resolved compositional and microstructural evolution to changes in thermophysical properties. The correlative analysis reveals that elemental leaching of Fe, Cr, and Ni from the stainless-steel container into the PCM drives the formation of intermetallic compounds (IMCs) both at the interface and within the bulk PCM, leading to pronounced compositional heterogeneity. These interfacial reactions and diffusion-induced transformations progressively destabilize the Al–Si eutectic, reducing the effective phase-transforming fraction. Consistent with these observations, DSC measurements show a decrease in melting temperature and latent heat of fusion with thermal cycling. These results underscore the critical influence of interfacial reactions and material compatibility on the stability, durability, and overall performance of Al–Si-based TES systems.

25 ENERGY STORAGE↗

Testing Low-Energy, High-Power Energy Storage Alternatives in a Full-Hybrid Vehicle (Presentation)

Automakers have been mass producing hybrid electric vehicles (HEVs) for well over a decade, and the technology has proven to be very effective at reducing per-vehicle gasoline use. However, the battery cost in HEVs contribute to higher incremental cost of HEVs (a few thousand dollars) than the cost of comparable conventional vehicles, which has limited HEV market penetration. Significant cost reductions/performance improvements to the energy storage system (ESS) can improve the vehicle-level cost vs. benefit relationship for HEVs. Such an improvement could lead to larger HEV market penetration and greater aggregate gasoline savings. After significant analysis by the National Renewable Energy Laboratory (NREL), the United States Advanced Battery Consortium (USABC) and Department of Energy (DOE) Energy Storage program suggested a new set of requirements for ESS for power-assist HEVs for cost reduction without impacting performance and fuel economy significantly. With support from DOE, NREL has developed an HEV test platform for in-vehicle performance and fuel economy validation testing of the hybrid system using such LEESS devices. This poster will describe development of the LEESS HEV test platform, and LEESS laboratory as well as in-vehicle evaluation results. The first LEESS technology tested was lithium-ion capacitors (LICs) - i.e., asymmetric electrochemical energy storage devices possessing one electrode with battery-type characteristics (lithiated graphite) and one with ultracapacitor-type characteristics (carbon). We will discuss the performance and fuel saving results with LIC with comparison with original NiMH battery.

25 ENERGY STORAGE↗

A New Family of Proton‐Conducting Electrolytes for Reversible Solid Oxide Cells: BaHf x Ce 0.8− x Y 0.1 Yb 0.1 O 3− δ

Abstract Reversible solid oxide cells based on ceramic proton conductors have potential to be the most efficient system for large‐scale energy storage. The performance and long‐term durability of these systems, however, are often limited by the ionic conductivity or stability of the proton‐conducting electrolyte. Here new family of solid oxide electrolytes, BaHf x Ce 0.8− x Y 0.1 Yb 0.1 O 3− δ (BHCYYb), which demonstrate a superior ionic conductivity to stability trade‐off than the state‐of‐the‐art proton conductors, BaZr x Ce 0.8− x Y 0.1 Yb 0.1 O 3− δ (BZCYYb), at similar Zr/Hf concentrations, as confirmed by thermogravimetric analysis, Raman, and X‐ray diffraction analysis of samples over 500 h of testing are reported. The increase in performance is revealed through thermodynamic arguments and first‐principle calculations. In addition, lab scale full cells are fabricated, demonstrating high peak power densities of 1.1, 1.4, and 1.6 W cm −2 at 600, 650, and 700 °C, respectively. Round‐trip efficiencies for steam electrolysis at 1 A cm −2 are 78%, 72%, and 62% at 700, 650, and 600 °C, respectively. Finally, CO 2 H 2 O electrolysis is carried out for over 700 h with no degradation.

Murphy, Ryan↗

Fe-single atom catalysts facilitate fast electron transfer with MoS 2 /SnS 2 cathodes in lithium–sulfur batteries

Lithium–sulfur batteries (LSBs) emerge as promising next-generation energy storage systems offering cost-effectiveness, environmental friendliness, and high theoretical energy density. The practical implementation of LSBs faces significant hindrances due to the shuttle effect and sluggish redox reactions. To address these challenges, single-atom catalyst (SAC) based combination materials from d-block elements can offer increased active catalytic sites, rapid charge transfer, accelerated electron migration, and fast sulfur redox conversion kinetics of lithium polysulfides (LiPSs). In this study, we fabricated three different LSB cathodes: pure S, S@MoS 2 /SnS 2 , and S@Fe–MoS 2 /SnS 2 . These cathodes were then used to explore the cycle life, capacity, rate capability, and redox kinetic reactions of LiPSs while assessing the influence of Fe-SACs on their performance. As a result, LSBs with S@Fe–MoS 2 /SnS 2 cathodes demonstrate an extended cycle life of 1000 cycles at a C-rate of 0.2C, maintaining a capacity close to 500 mA h g −1 , the highest initial discharge capacity of 1622 mA h g −1 and 1066 mA h g −1 at 0.05C and 0.2C, and excellent rate capabilities of 708 mA h g −1 and 558 mA h g −1 at 1C and 2C, respectively. The synergistic effect of the Fe-SAC-based combination cathode (S@Fe–MoS 2 /SnS 2 ) creates plentiful adsorptive and highly active catalytic sites, resulting in substantially enhanced capacity for adsorbing soluble long-chain LiPSs. This facilitates ultra-fast redox kinetics, surpassing the performance of the S@MoS 2 /SnS 2 and pure S cathodes. In the ex situ analysis, results from powder X-ray diffraction (XRD) to observe the new phase, soft X-ray absorption spectroscopy (XAS) to investigate the electronic structure, and hard X-ray photoelectron microscopy (HAXPES) with different energies (900 eV, 2000 eV, and 6000 eV) to track the chemical-state evolution of Fe-SACs in MoS 2 /SnS 2 cathodes displayed notable electrochemical reversibility involving S 8 ⇄ LiPSs ⇄ Li 2 S conversion even after 1000 cycles. Additionally, in situ, operando Raman analysis can unveil a novel catalytic mechanism of Fe-SACs in MoS 2 /SnS 2 “facilitating rapid electron transfer” during the discharge and charge processes of LSBs involving the conversion of S 8 ⇄ long-chain LiPSs ⇄ Li 2 S 2 /Li 2 S. This study elucidates the working mechanism of Fe-SAC cathodes, offering insights into overcoming the shuttle effect and facilitating sulfur redox kinetics to advance commercial LSBs.

36 MATERIALS SCIENCE↗

Parametric Modeling and Economic Analysis of a 2MW th 3-Stream sCO 2 Heat Exchanger

Here, this paper presents the design and cost optimization of a novel 2MW th 3-stream sCO2 plate-fin heat exchanger. This heat exchanger design is unique in that it uses reduced metal oxide particle-to-sCO2 heat exchanger for cost-effective energy storage applications. The design uses low velocity, laminar air as the re-oxidizing reactant to transfer the heat of the re-oxidizing reaction to a sCO2 power loop. The design of the heat exchanger is based on a 2-D, 3-fluid plate/fin heat transfer model. The model parameterizes the size, shape, and number of passages of the heat exchanger to calculate the temperature profile, pressure drop, and fluid velocities of all three fluids. Global heat exchanger parameters such as the effectiveness and total heat transferred to the sCO2 are then calculated for overall performance. Due to the value and increased use of sCO2 heat exchangers in power cycles, a cost model of the system based on the unique high temperature/high pressure operating conditions was created using quotes from reference projects and market analysis. These quoted air-to-sCO2 heat exchangers are then processed using multiple weighting factors pertinent to heat exchanger design, including heat exchanger type, maximum temperature, differential pressures, fluids, duty, and more. These factors are then used in an exponential function in order to generate a parameterized cost curve. The design and cost of the heat exchanger are then optimized using the SMPSO genetic algorithm in Python. The optimization objectives for the system are to maximize the overall system effectiveness, including an air recuperator for preheating, and to minimize unit costs. Additional constraints are added to the system for the sCO2 and air pressure drops, air velocity to reduce particle entrainment, and the length and volume of the heat exchanger.

Cost Model↗

Implementation of Increased Salt and Decreased Sludge Volumes in the Defense Waste Processing Facility - 19597

The Savannah River Site (SRS) Liquid Waste System (LWS) safely stores and treats high-level radioactive waste. The LWS consists of 51 waste storage tanks (eight of which are operationally closed and filled with grout), waste evaporators, treatment facilities, and solidification facilities such as the Defense Waste Processing Facility (DWPF) and Saltstone Production Facility (SPF). The disposition of high-level waste (HLW) into a glass waste form poured into canisters at the DWPF began in 1996. DWPF processed a sludge only flowsheet until 2008 when the Actinide Removal Process (ARP) and Modular Caustic Side Solvent Extraction Unit (MCU) began treating the salt waste from the underground liquid storage tanks by striking with monosodium titanate (MST) to remove actinides, when necessary to meet downstream acceptance criteria, and removing the MST and entrained sludge solids (SS) by filtration before using an organic solvent to strip the cesium from the salt, creating two new concentrated HLW streams. This change caused the DWPF to begin processing under both a sludge-only and a coupled operations flowsheet where salt streams would only be added when available. This strategy allows for continuous glass canister production at DWPF. Recently, DWPF completed a 10-month melter replacement in December 2017 and the Concentrate, Storage, and Transfer Facility (CSTF) has completed repairs to the 3H Evaporator system. These facility outages have caused delays in preparing the next batch of sludge feed for DWPF. Concurrent with these facility outages, the Salt Waste Processing Facility (SWPF) has been undergoing system testing and commissioning, working toward startup. SWPF is designed to process salt waste in the same manner as ARP/MCU, but with much higher throughput volumes produced per unit time. In order to process the SWPF salt streams efficiently, DWPF will implement a coupled operation only flowsheet. Based on the facility outages mentioned above, efforts have been made to identify strategies to minimize sludge volumes and maximize salt volumes in the DWPF until the next sludge batch is ready for processing in DWPF. Savannah River Remediation (SRR) recently performed an evaluation that examines the effects of reducing the volume of sludge and maximizing the addition of the cesium-rich concentrated salt solution in each Sludge Receipt and Adjustment Tank (SRAT) batch in order to extend the existing sludge batch as long as possible until the next sludge batch is ready. These effects include a reduction of weight percent solids in the DWPF processing vessels, an increase in cycle time, a new canister heat generation value that remains within regulatory limits, and higher gamma source that remains within bulk facility gamma shielding. Balancing the above parameters resulted in a small reduction of sludge volume per SRAT batch under SWPF operation and maximizing the salt volumes for both ARP/MCU and SWPF operation. This slight reduction in sludge volume and increase in salt volumes allows SRR to mitigate some of the schedule impact incurred by the facility outages. This strategy was evaluated for both ARP/MCU and SWPF operation. This strategy has been successfully implemented under ARP/MCU operation using small step changes in the current process. This paper provides an overview of the evaluation performed for DWPF with ARP/MCU and DWPF with SWPF operations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Corrective Maintenance Paradigm Shift at Hanford's Tank Farms - 20077

Hanford's Tank Farms facilities have been used to safely store waste for over 70 years, with the first single-shell tanks being constructed in 1943. Tank Farm facilities consist of 149 single-shell tanks, 28 double-shell tanks, an evaporator facility, and wastewater treatment facilities. Tank Farm facilities are aging, with a tremendous corrective maintenance burden on the Tank Farm contractor. The mission of Tank Farm facilities is soon changing from waste storage to waste staging for the Hanford Waste Treatment and Immobilization Plant (WTP). WTP operations will demand a significant increase in Tank Farm facility operations, in which corrective maintenance outage windows will shrink drastically. This realization has forced the Tank Farm contractor to consider a paradigm shift in Tank Farm facilities Maintenance planning, and the use of reliability Engineering tools. The Tank Farm Production Operations Engineering Cognizant System Engineering (CSE) organization has led the way in motivating this paradigm shift. This shift has been realized through the use of: 1) technical exchange with other Department of Energy (DOE) contractors to develop improvements in the CSE program, 2) a shift from the use of lagging to leading system health indicators, and 3) a Plant Health Committee to unite Engineering, Operations, and Maintenance personnel toward a productive maintenance strategy. The CSE organization has held several technical exchanges with other DOE contractors to discuss CSE concepts, and how to better maintain aging infrastructure. The technical exchange with other contractors has greatly reduced the time required to make improvements in the Tank Farm CSE program. Other DOE contractors have already faced issues surrounding aging infrastructure, and have vast experience in improving the reliability and usable life of structures and components in nuclear facilities. The past CSE program used lagging health indicators to determine the health of systems. The key lagging indicator used to determine system health was availability, which is the percentage of time that a facility was ready for operation compared to the time the facility was demanded for operation. Availability was a good indicator of health in the waste storage mission of Tank Farms, where safe storage was the most important function of the facility, and where maintenance outage windows were typically long-duration. In current and future operations, outage windows are reducing, resulting in the need for much more reliable systems. Systems that have had high availability may suddenly become inoperable due to a failed component or sub-system. In several instances, the use of availability as an indicator of system health failed to predict system/equipment failure before its occurrence. In discussions with other DOE contractors, a set of reliability tools, including leading indicators of health, has been implemented in the CSE program. This primarily involves the use of failure modes and effects analysis and the study of equipment failure to develop system monitoring plans that focus on trending data to detect oncoming equipment failure ahead of time. In addition, the use of a Plant Health Committee has added significantly to the paradigm shift from a corrective maintenance philosophy to the use of predictive and preventive maintenance. The Plant Health Committee is a chartered team consisting of Engineering, Operations, and Maintenance personnel. CSEs use this forum to present the results of their performance monitoring, including the presentation of health via leading health indicators. The most positive aspect of this committee is the communication that it creates within these critical organizations. The Operations and Maintenance organization benefit from focusing maintenance on the reliability-centered focus provided by Engineering. Engineering benefits from the operational experience of the Operations organization and from the failure data that can be provided by Maintenance personnel. The continued use of the Plant Health Committee is expected to further decrease maintenance outage times, in better support of oncoming 24/7 operations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Successful Deployment of System for the Storage and Retrieval of Spent/Used Nuclear Fuel from Hanford K-West Fuel Storage Basin-13051

In 2012, a system was deployed to remove, transport, and interim store chemically reactive and highly radioactive sludge material from the Hanford Site's 105-K West Fuel Storage Basin that will be managed as spent/used nuclear fuel. The Knockout Pot (KOP) sludge in the 105-K West Basin was a legacy issue resulting from the spent nuclear fuel (SNF) washing process applied to 2200 metric tons of highly degraded fuel elements following long-term underwater storage. The washing process removed uranium metal and other non-uranium constituents that could pass through a screen with 0.25-inch openings; larger pieces are, by definition, SNF or fuel scrap. When originally retrieved, KOP sludge contained pieces of degraded uranium fuel ranging from 600 microns (μm) to 6350 μm mixed with inert material such as aluminum hydroxide, aluminum wire, and graphite in the same size range. In 2011, a system was developed, tested, successfully deployed and operated to pre-treat KOP sludge as part of 105-K West Basin cleanup. The pretreatment process successfully removed the vast majority of inert material from the KOP sludge stream and reduced the remaining volume of material by approximately 65 percent, down to approximately 50 liters of material requiring management as used fuel. The removal of inert material resulted in significant waste minimization and project cost savings because of the reduced number of transportation/storage containers and improvement in worker safety. The improvement in worker safety is a result of shorter operating times and reduced number of remote handled shipments to the site fuel storage facility. Additionally in 2011, technology development, final design, and cold testing was completed on the system to be used in processing and packaging the remaining KOP material for removal from the basin in much the same manner spent fuel was removed. This system was deployed and successfully operated from June through September 2012, to remove and package the last of the SNF fragments from the 105-K West Basin, ending the long and complex history of the KOP sludge materials. The planning and execution of this project demonstrated how the graded application of DOE O 413.3B, Program and Project Management for the Acquisition of Capital Assets[1], DOE-STD-1189-2008, Integration of Safety into the Design Process[2], and DOE G 413.3-4, U.S. Department of Energy Technology Readiness Assessment Guide[3], can positively affect the outcome of project implementation in the DOE Complex. Provided herein are relevant information, ideas, and tools for use by other projects facing similar issues in managing high risk waste streams in a complex regulatory environment. Positive aspects are also provided of appropriate time spent in detailed planning, design, and testing in non-hazardous environments to reduce project risks in both cost and safety performance, as well as improving confidence in meeting project goals through predictable and reliable performance. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced Drying Cycle Simulator Thermal Response to Commercial Drying Conditions

The purpose of this report is to document updates on testing of the apparatus built to simulate commercial drying procedures for spent nuclear fuel at the Nuclear Energy Work Complex at Sandia National Laboratories. Validation of the extent of water removal in a dry spent nuclear fuel storage system based on drying procedures used at nuclear power plants is needed to close existing technical gaps. Operational conditions leading to incomplete drying may have potential impacts on the fuel, cladding, and other components in the system during subsequent storage and disposal. A general lack of data suitable for model validation of commercial nuclear canister drying processes necessitates well-designed investigations of drying process efficacy and water retention that incorporate relevant physics and well-controlled boundary conditions. This report documents testing updates for the Advanced Drying Cycle Simulator (ADCS). This apparatus was built to simulate commercial drying procedures and quantify the amount of residual water remaining in a pressurized water reactor (PWR) fuel assembly after drying. The ADCS was constructed with a prototypic 17×17 PWR fuel skeleton and waterproof heater rods to simulate decay heat. These waterproof heaters are the next generation design to heater rods developed and tested at Sandia National Laboratories in FY20. This report describes preliminary testing of the ADCS through measurement and analysis of the thermal response of the system to a subset of commercial drying conditions that exclude the introduction of water, namely simulated decay heats and pressures relevant to commercial drying. This test series, referred to as a “dry” test series in this report, spans three uniform waterproof heater rod powers (representing spent fuel decay heats), four helium fill pressures, and six vacuum levels. This test series was conducted to cover the range of expected ADCS testing conditions for upcoming “wet” testing, where water will be introduced and a simulated commercial drying cycle will be performed. The dry test conditions were derived from the commercial drying conditions seen in the High Burnup Demonstration and the vacuum drying conditions chosen for a smaller scale Dashpot Drying Apparatus tested at Sandia National Laboratories in FY22. For a given uniform power and pressure/vacuum level, the ADCS was operated at constant power and pressure and allowed to reach steady state conditions. The thermal data obtained from these tests were analyzed, and the results can inform computational models built to simulate commercial drying processes by providing baseline thermal data prior to the introduction of water. Following the preliminary dry tests, a test plan for the ADCS will be developed to implement a drying procedure that begins with the introduction of water to the system and is based on measurements from the drying process used for the High Burnup Demonstration Project. While applying power to the simulated fuel rods, this procedure is expected to consist of filling the ADCS vessel with water, draining the water with applied pressure and multiple helium blowdowns, evacuating additional water with a vacuum drying sequence at successively lower pressures, and backfilling the vessel with helium. Additional investigations are expected to feature failed fuel rod simulators with engineered cladding defects and guide tubes with obstructed dashpots to challenge the drying system with multiple water retention sites. The data from these investigations is expected to inform the efficacy of commercial drying operations through the quantification of residual water in a prototypic-length dry storage canister.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Atomic Layer Deposition for Lithium-Based Batteries

With the increasing demand for energy at a low cost and minimal environmental impact, the development of next-generation high-performance batteries has drawn considerable attention. Owing to the capability of forming conformal coatings of thin films and nanoparticles, atomic layer deposition (ALD) has shown great potential in deposition and surface modification of electrode materials with various nanostructures, deposition of solid-state electrolyte, and fabrication of electrochemical catalysts. This paper reviews the recent development and applications of ALD in Li-based batteries, especially beyond Li-ion systems, and provides suggestions for further development of ALD techniques for these batteries.

25 ENERGY STORAGE↗

The Influence of Charge Correlation and Ion Solvation on the Phase Behavior of Single-Ion Conducting Polymer Blend Electrolytes Using SAXS/SANS

Single-ion conducting polymer blends (SICPBs) have demonstrated exceptional electrochemical performance as solid-state battery electrolytes; however, their nanoscale morphology and thermodynamic behavior remain unexplored. In this work, we investigate blends composed of deuterated poly(ethylene oxide) and poly[lithium sulfonyl(trifluoromethane sulfonyl)imide methacrylate], dPEO/P(LiMTFSI), and report the first experimental study of the nanostructures of charge-neutral polymer blends using small-angle neutron scattering (SANS) and small-angle X-ray scattering (SAXS). Despite the macroscopic miscibility indicated by a single glass-transition temperature, SANS and SAXS results reveal disordered, charge-correlated nanostructures that are strongly influenced by blend composition and temperature. At low concentrations of charge polymer, the scattering is dominated by concentration fluctuations, and the random phase approximation is applied to extract values of the Flory–Huggins interaction parameter, χ SC . At higher charged polymer content, concentration fluctuations are suppressed, and a correlation model is used to characterize the nanostructures of the charge correlations. We find that the structures of the charge correlations are highly dependent on blend composition─consistent with predictions from Sing’s self-consistent field theory-liquid state models. Understanding these features is essential for uncovering the ion transport mechanism that leads to improved electrochemical performance previously reported in SICPB systems.

25 ENERGY STORAGE↗

Advanced Grid Simulator for Multi-Megawatt Power Converter Testing and Certification

Grid integration testing of inverter-coupled renewable energy technologies is an essential step in the qualification of renewable energy and energy storage systems to ensure the stability of the power system. New types of devices must be thoroughly tested and validated for compliance with relevant grid codes and interconnection requirements. For this purpose, highly specialized custom-made testing equipment is needed to emulate various types of realistic grid conditions that are required by certification bodies or for research purposes. For testing multi-megawatt converters, a high power grid simulator capable of creating controlled grid conditions and meeting both power quality and dynamic characteristics is needed. This paper describes the new grid simulator concept based on ABB's medium voltage ACS6000 drive technology that utilizes advanced modulation and control techniques to create an unique testing platform for various multi-megawatt power converter systems. Its performance is demonstrated utilizing the test results obtained during commissioning activities at the National Renewable Energy Laboratory in Colorado, USA.

17 WIND ENERGY↗

Heavy-Duty Hydrogen Station Equipment Performance Device (HD HyStEP) Specifications and Design Considerations

The original Hydrogen Station Equipment Performance (HyStEP) device was commissioned in 2015 and was critical for the rapid validation of light-duty (LD) hydrogen fueling stations. As applications for hydrogen as a heavy-duty (HD) transportation fuel continue to grow, new heavy-duty stations are being developed to fuel these vehicles that require larger onboard storage tank systems to meet HD transportation demands and drive cycles. The differences in size and geometry from LD vehicles have driven the creation of new hydrogen fueling protocols that will enable safe and economical fueling of HD vehicles. With the new requirements that are set out in HD fueling protocols like SAE J601-5, a new HyStEP-like device is needed to evaluate the capabilities of high-flow hydrogen stations to fuel HD vehicles to the new protocol standard. To create a heavy-duty HyStEP (HD HyStEP) device, an effort has been undertaken to evaluate the requirements that would form the basis for the design of a successful HD HyStEP device. The primary design goal of this HD HyStEP device is its capability of following a test methodology similar to what is outlined in CSA HGV 4.3, which guides the validation of LD fueling dispensers but with adjustments to verify adherence to the HD fueling protocols (SAE J2601-5) for 70 MPa and 35 MPa pressure class vehicles rather than the LD fueling protocols (SAE J2601). The design presented here aims to provide information that enables the creation of an HD HyStEP device that achieves the primary design goal while being informed by the years of experience from the current HyStEP operators.

08 HYDROGEN↗

TRANSIENT ACCIDENT ANALYSIS OF THE GLOVEBOX SYSTEM IN A LARGE PROCESS ROOM

Local transient hydrogen concentrations were evaluated inside a large process room when the hydrogen gas was released by three postulated accident scenarios associated with the process tank leakage and fire leading to a loss of gas confinement. The three cases considered in this work were fire in a room, loss of confinement from a process tank, and loss of confinement coupled with fire event. Based on these accident scenarios in a large and unventilated process room, the modeling calculations of the hydrogen migration were performed to estimate local transient concentrations of hydrogen due to the sudden leakage and release from a glovebox system associated with the process tank. The modeling domain represented the major features of the process room including the principal release or leakage source of gas storage system. The model was benchmarked against the literature results for key phenomena such as natural convection, turbulent behavior, gas mixing due to jet entrainment, and radiation cooling because these phenomena are closely related to the gas driving mechanisms within a large air space of the process room. The modeling results showed that at the corner of the process room, the gas concentrations migrated by the Case 2 and Case 3 scenarios reached the set-point value of high activity alarm in about 13 seconds, while the Case 1 scenario takes about 90 seconds to reach the concentration. The modeling results were used to estimate transient radioactive gas migrations in an enclosed process room installed with high activity alarm monitor when the postulated leakage scenarios are initiated without room ventilation.

08 HYDROGEN↗