Search NASA⌕ Search

SEARCH · Search NASA

Results for “Infrared techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Characterization of Composite Damage Using Passive Thermography

Passive thermography is used to monitor small increases in temperature on a composite structure during loading. A rise in temperature can be attributed to damage formation due to matrix cracking and fiber breaks. An infrared camera allows for imaging the damage location, size, and shape. Recently, a technique has been developed to estimate the depth of the damage in a composite hat-stiffened panel during quasi-static loading. This technique is based on two heat generation components. The first component is an instantaneous thermoelastic response due to a strain release. The second component is mechanical heating, at the interface of failure, due to fracture damage. This second component produces a transient rise in temperature that is a function of the damage depth and thermal diffusivity. The first component defines the thermal start time for the transient response. A one-dimensional thermal model is used to determine the damage depth for a known thermal diffusivity. The results are compared to ultrasonic and X-ray CT data and show good agreement for damage depth.

Thermal nondestructive evaluation↗

Laser Timing Jitter Measurements using a Dual-Sweep Streak Camera at the A0 Photoinjector

Excellent phase stability of the drive laser is a critical performance specification of photoinjectors such as Fermilab's A0 photoinjector (A0PI). Previous efforts based on the measurement of the power spectrum of the signal of a fast photodiode illuminated by the mode locked infrared laser pulse component indicated a phase jitter of less than 1.4 ps (technique limited). A recently procured dual sweep plugin unit and existing Hamamatsu C5680 streak camera were used to study the phase stability of the UV laser pulse component. Initial measurements with the synchroscan vertical sweep unit locked to 81.25 MHz showed that the phase slew through the micropulse train and the phase jitter micropulse to micropulse were two key aspects that could be evaluated. The phase slew was much less than 100 fs per micropulse, and the total phase jitter (camera, trigger, and laser) was approximately 300 fs RMS for measurements of 50-micropulse trains. Data on the macropulse phase stability were also obtained. A possible upgrade to achieve better phase stability will be also discussed.

43 PARTICLE ACCELERATORS↗

Compact TDLAS based optical sensor for ppb-level ethane detection by use of a 3.34 μm room-temperature CW interband cascade laser

A mid-infrared ethane (C 2 H 6 ) sensor based on a wavelength modulation spectroscopy (WMS) technique was developed using a thermoelectrically cooled (TEC), continuous-wave (CW) interband cascade laser (ICL) emitting at 3.34 μm and a dense multi-pass gas cell (MPGC, 17 × 6.5 × 5.5 cm 3 ) with a 54.6 m optical path length. A compact optical sensor system with a physical size of 35.5 × 18 × 12.5 cm 3 was designed and constructed. An ICL was employed for targeting a strong C 2 H 6 line at 2996.88 cm -1 at <100 Torr gas pressure in the fundamental absorption band of C 2 H 6 . The sensor performance, including the minimum detection limit (MDL) and the stability were improved by reducing the effect of laser power drift by means of the 2f/1f-WMS technique. A MDL of ~1.2 parts per billion (ppbv) for 2f-WMS and ~1.0 ppbv for 2f/1f-WMS were achieved, respectively, with a measurement time of 4 s. The MDL was further improved from 299 pptv (@108 s for 2f-WMS) to 239 pptv (@208 s for 2f/1f-WMS), based on an Allan deviation analysis.The rise time (@0 → 100 ppbv) and fall time (@100 → 0 ppbv) were determined to be ~64 s and ~48 s,respectively, at a gas pressure of <100 Torr for the C 2 H 6 sensor operation.

03 NATURAL GAS↗

Kinetics for the Sequential Infiltration Synthesis of Alumina in Poly(methyl methacrylate): An Infrared Spectroscopic Study

Sequential infiltration synthesis (SIS) is a method for growing inorganic materials within polymers in an atomically controlled fashion. This technique can increase the etch resistance of optical, electron-beam, and block copolymer (BCP) lithography resists and is also a flexible strategy for nanomaterials synthesis. Despite this broad utility, the kinetics of SIS remain poorly understood, and this knowledge gap must be bridged in order to gain firm control over the growth of inorganic materials inside polymer films at a large scale. In this paper, we explore the reaction kinetics for Al 2 O 3 SIS in PMMA using in situ Fourier transform infrared spectroscopy. First, we establish the kinetics for saturation adsorption and desorption of trimethyl aluminum (TMA) in PMMA over a range of PMMA film thicknesses deposited on silicon substrates. These observations guide the selection of TMA dose and purge times during SIS lithography to achieve robust organic/inorganic structures. Next, we examine the effects of TMA desorption on BCP lithography by performing SIS on silicon surfaces coated with polystyrene-block-poly(methyl methacrylate) films. After etching the organic components, the substrates are examined using scanning electron microcopy to evaluate the resulting Al 2 O 3 patterns. Finally, we examine the effects of temperature on Al 2 O 3 SIS in PMMA to elucidate the infiltration kinetics. The insights provided by these measurements will help extend SIS lithography to larger substrate sizes for eventual commercialization and expand our knowledge of precursor-polymer interactions that will benefit the SIS of a wide range of inorganic materials in the future.

Biswas, Mahua↗

Metrology and Failure Analysis for 3D IC Integration

At the same time as research in 3D TSV technology is advancing quickly, the analytical techniques used in the evaluation of 3D stacks must also advance in capability. Microscopy techniques for which silicon is opaque such as scanning acoustic microscopy (SAM) and confocal infrared (IR) microscopy are capable of inspecting the interface between bonded wafer pairs, while high resolution X-ray computed tomography (XCT) is used to detect voids in TSVs. With nano-XCT, voids in copper TSVs with sub-100 nm size can be visualized. For more detailed failure characterization, a target Focused Ion Beam (FIB) cross-section through the localized region of interest (defect) and subsequent scanning electron microscopy (SEM) imaging is proposed. Currently, the most important requirement is to reduce the so-called time-to-data, e. g. for defect localization using nano-XCT and for cross-section characterization.

36 MATERIALS SCIENCE↗

Spectral identification of minerals using imaging spectrometry data: Evaluating the effects of signal to noise and spectral resolution using the tricorder algorithm

The rapid development of sophisticated imaging spectrometers and resulting flood of imaging spectrometry data has prompted a rapid parallel development of spectral-information extraction technology. Even though these extraction techniques have evolved along different lines (band-shape fitting, endmember unmixing, near-infrared analysis, neural-network fitting, and expert systems to name a few), all are limited by the spectrometer's signal to noise (S/N) and spectral resolution in producing useful information. This study grew from a need to quantitatively determine what effects these parameters have on our ability to differentiate between mineral absorption features using a band-shape fitting algorithm. We chose to evaluate the AVIRIS, HYDICE, MIVIS, GERIS, VIMS, NIMS, and ASTER instruments because they collect data over wide S/N and spectral-resolution ranges. The study evaluates the performance of the Tricorder algorithm, in differentiating between mineral spectra in the 0.4-2.5 micrometer spectral region. The strength of the Tricorder algorithm is in its ability to produce an easily understood comparison of band shape that can concentrate on small relevant portions of the spectra, giving it an advantage over most unmixing schemes, and in that it need not spend large amounts of time reoptimizing each time a new mineral component is added to its reference library, as is the case with neural-network schemes. We believe the flexibility of the Tricorder algorithm is unparalleled among spectral-extraction techniques and that the results from this study, although dealing with minerals, will have direct applications to spectral identification in other disciplines.

Swayze, Gregg A.↗

Finite field of view effects on inversion of limb thermal emission observations

It is pointed out that the technique of thermal emission spectroscopy provides an effective means for remote sounding of stratospheric temperature structure and constituent distributions. One procedure for measuring the stratospheric infrared spectrum involves the conduction of observations along ray paths tangent to the stratospheric limb. Thermal emission limb tangent observations have certain advantages compared to other types of observations. The techniques for determining temperature and trace gas distributions from limb thermal emission radiances are based on the assumption that the bulk of opacity lies near the tangent point. Ideally, the field of view (FOV) of the observing instrument should be very small. The effect of a finite FOV is to reduce the spatial resolution of the retrieved temperature and constituent profiles. The present investigation is concerned with the effects of the FOV on the inversion of infrared thermal emission measurements for balloon platforms. Attention is given to a convenient method for determining the weighting functions.

Abbas, M. M.↗

Evaluation of Methods to Estimate the Surface Downwelling Longwave Flux during Arctic Winter

Surface longwave radiation fluxes dominate the energy budget of nighttime polar regions, yet little is known about the relative accuracy of existing satellite-based techniques to estimate this parameter. We compare eight methods to estimate the downwelling longwave radiation flux and to validate their performance with measurements from two field programs in thc Arctic: the Coordinated Eastern Arctic Experiment (CEAREX ) conducted in the Barents Sea during the autumn and winter of 1988, and the Lead Experiment performed in the Beaufort Sea in the spring of 1992. Five of the eight methods were developed for satellite-derived quantities, and three are simple parameterizations based on surface observations. All of the algorithms require information about cloud fraction, which is provided from the NASA-NOAA Television and Infrared Observation Satellite (TIROS) Operational Vertical Sounder (TOVS) polar pathfinder dataset (Path-P): some techniques ingest temperature and moisture profiles (also from Path-P): one-half of the methods assume that clouds are opaque and have a constant geometric thickness of 50 hPa, and three include no thickness information whatsoever. With a somewhat limited validation dataset, the following primary conclusions result: (1) all methods exhibit approximately the same correlations with measurements and rms differences, but the biases range from -34 W sq m (16% of the mean) to nearly 0; (2) the error analysis described here indicates that the assumption of a 50-hPa cloud thickness is too thin by a factor of 2 on average in polar nighttime conditions; (3) cloud-overlap techniques. which effectively increase mean cloud thickness, significantly improve the results; (4) simple Arctic-specific parameterizations performed poorly, probably because they were developed with surface-observed cloud fractions; and (5) the single algorithm that includes an estimate of cloud thickness exhibits the smallest differences from observations.

Chiacchio, Marc↗

Temperature control of silica mirrors for cryogenically-cooled telescopes in space

The SIRTF (Space Infrared Telescope Facility) optical subsystem, including the primary mirror, has been modeled using lumped-parameter techniques and a thermal and cryogenic transient analysis program developed previously. Since silica mirrors have been shown to have significantly less distortion due to cryogenic cooldown, a silica primary mirror of approximately 1 m diameter is being considered. Thermal responses to variations in aperture heat load and heat sink temperature have been explored. Calculations have been made of system noise components from primary mirror spatial and temporal temperature variations. Background-limited infrared observations can be made at wavelengths out to 200 micrometers. Mirror thermal performance with and without copper wires for cooling is also considered.

Melugin, R. K.↗

Multi-technique characterization of iron reduction by an Antarctic Shewanella : an analog system for putative Martian biosignature identification

ABSTRACT Microbes from terrestrial extreme environments enable testing of biosignature production in conditions relevant to astrobiological targets. Mars, which was likely more conducive to life during early warmer and wetter epochs, has inspired missions that search for signs of early life in the surficial rock record, including mineral or organic biosignatures. Microbial iron reduction is a common and ancient metabolism that may have also operated on other rocky celestial bodies. To investigate biosignature production during iron reduction, aShewanellasp. (strain BF02_Schw) isolated from a subglacial discharge known as Blood Falls, Antarctica, was incubated with the electron acceptor ferrihydrite (Fh). Biosignatures associated with Fh reduction were identified using a suite of techniques currently utilized or proposed for Mars missions, including X-ray diffraction and infrared, Mössbauer, and Raman spectroscopy. The biotic origin of features was validated by transcriptional changes observed between treatments with and without Fh and comparison to killed controls. In live treatments, Fh was reduced to magnetite and goethite, both detected in Martian lacustrine basins. Several soluble and volatile metabolites were also detected, including riboflavin and dimethyl sulfide (DMS), which could be astrobiological indicators of active microbial processes. While none of the identified biosignatures individually would serve as definitive proof of life (past or present), detecting concomitant features associated with known terrestrial biotic processes would provide compelling rationale for more targeted life detection missions. Terrestrial extremophiles can support the exploration of astrobiologically relevant microbial processes, validation of life detection instrumentation, and potentially the discovery of new biomarkers. IMPORTANCE Culture-based experiments with terrestrial extremophiles can elucidate biosignatures that may be analogous to those produced under extraterrestrial conditions, and thus inform sampling and technology strategies for future missions. Here, we demonstrate the production of several biosignatures under iron-reducing conditions byShewanellasp. BF02_Schw, originally isolated from an Antarctic analog feature. These biosignatures could be detectable using flight-ready instrumentation. Growth experiments with terrestrial extremophiles can identify biosignatures measurable by current methodologies and inform the development and optimization of techniques for detecting extant or extinct life on other worlds.

Biotechnology & Applied Microbiology↗

Comparison of Spectroscopic Techniques for Determining the Peroxide Value of 19 Classes of Naturally Aged, Plant-Based Edible Oils

The peroxide value of edible oils is a measure of the degree of oxidation, which directly relates to the freshness of the oil sample. Several studies previously reported in the literature have paired various spectroscopic techniques with multivariate analyses to rapidly determine peroxide values using field portable and process instrumentation; those efforts presented “best-case scenarios” with oils from narrowly defined training and test sets. The purpose of this paper is to evaluate the use of near- and mid-infrared absorption and Raman scattering spectroscopies on oil samples from different oil classes, including seasonal and vendor variations, to determine which measurement technique or combination thereof is best for predicting peroxide values. Following peroxide value assays of each oil class using an established titration-based method, global and global-subset calibration models were constructed from spectroscopic data collected on the 19 oil classes used in this study. Spectra from each optical technique were used to create partial least squares regression calibration models to predict the peroxide value of unknown oil samples. A global peroxide value model based on near-infrared (8 mm optical path length) oil measurements produced the lowest RMSEP (4.9), followed by 24 mm optical path length near infrared (5.1), Raman (6.9) and 50 µm optical path length mid-infrared (7.3). However, it was determined that the Raman RMSEP resulted from chance correlations. Global peroxide value models based on low-level fusion of the NIR (8 and 24 mm optical path length) data and all infrared data produced the same RMSEP of 5.1. Global subset models, based on any of the spectroscopies and olive oil training sets from any class (pure, extra light, extra virgin), all failed to extrapolate to the non-olive oils. However, the near-infrared global subset model built on extra virgin olive oil could extrapolate to test samples from other olive oil classes. This work demonstrates the difficulty of developing a truly global method for determining peroxide value of oils.

36 MATERIALS SCIENCE↗

SEARCHING FOR THE HIGHEST REDSHIFT SOURCES IN 250-500 {mu}m SUBMILLIMETER SURVEYS

We explore a technique for identifying the highest redshift (z>4) sources in Herschel/SPIRE and BLAST submillimeter surveys by localizing the position of the far-infrared dust peak. Just as Spitzer/IRAC was used to identify stellar 'bump' sources, the far-IR peak is also a redshift indicator; although the latter also depends on the average dust temperature. We demonstrate the wide range of allowable redshifts for a reasonable range of dust temperatures and show that it is impossible to constraint the redshift of individual objects using solely the position of the far-IR peak. By fitting spectral energy distribution models to simulated Herschel/SPIRE photometry we show the utility of radio and/or far-infrared data in breaking this degeneracy. With prior knowledge of the dust temperature distribution it is possible to obtain statistical samples of high redshift submillimeter galaxy (SMG) candidates. We apply this technique to the BLAST survey of ECDFS to constrain the number of dusty galaxies at z>4. We find 8 {+-} 2 galaxies with flux density ratios of S {sub 500}>S {sub 350}; this sets an upper limit of 17 {+-} 4 deg{sup -2} if we assume all are at z>4. This is <35 % of all 500 {mu}m-selected galaxies down to S {sub 500}>45 mJy (L {sub IR}>2 x 10{sup 13} L {sub sun} for z>4). Modeling with conventional temperature and redshift distributions estimates the percentage of these 500 {mu}m peak galaxies at z>4 to be between 10% and 85%. Our results are consistent with other estimates of the number density of very high redshift SMGs and follow the decline in the star formation rate density at z>4.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantum Mechanical Modeling of the Vibrational Spectra of Minerals with a Focus on Clays

We present an overview of how to use quantum mechanical calculations to predict vibrational frequencies of molecules and materials such as clays and silicates. Other methods of estimating vibrational frequencies are mentioned, such as classical molecular dynamics simulations; references are given for additional information on these approaches. Herein, we discuss basic vibrational theory, calculating Raman and infrared intensities, steps for creating realistic models, and applications to spectroscopy, thermodynamics, and isotopic fractionation. There are a wide variety of programs and methods that can be employed to model vibrational spectra, but this work focuses on hybrid density functional theory (DFT) approaches. Many of the principles are the same when used in other programs and DFT methods, so a novice can benefit from simple examples that illustrate key points to consider when modeling vibrational spectra. Other methods and programs are listed to give the beginner a starting point for exploring and choosing which approach will be best for a given problem. The modeler should also be aware of the numerous analytical methods available for obtaining information on vibrations of atoms in molecules and materials. In addition to traditional infrared and Raman spectroscopy, sum-frequency generation (SFG) and inelastic neutron scattering (INS) are also excellent techniques for obtaining vibrational frequency information in certain circumstances.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

IS THERE A METALLICITY CEILING TO FORM CARBON STARS?-A NOVEL TECHNIQUE REVEALS A SCARCITY OF C STARS IN THE INNER M31 DISK

We use medium-band near-infrared (NIR) Hubble Space Telescope WFC3 photometry with model NIR spectra of asymptotic giant branch (AGB) stars to develop a new tool for efficiently distinguishing carbon-rich (C-type) AGB stars from oxygen-rich (M-type) AGB stars in galaxies at the edge of and outside the Local Group. We present the results of a test of this method on a region of the inner disk of M31, where we find a surprising lack of C stars, contrary to the findings of previous C star searches in other regions of M31. We find only one candidate C star (plus up to six additional, less certain C star candidates), resulting in an extremely low ratio of C to M stars (C/M= (3.3{sup +20}{sub -0.1}) Multiplication-Sign 10{sup -4}) that is one to two orders of magnitude lower than other C/M estimates in M31. The low C/M ratio is likely due to the high metallicity in this region which impedes stars from achieving C/O > 1 in their atmospheres. These observations provide stringent constraints to evolutionary models of metal-rich AGB stars and suggest that there is a metallicity threshold above which M stars are unable to make the transition to C stars, dramatically affecting AGB mass loss and dust production and, consequently, the observed global properties of metal-rich galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Infrared upconversion for astronomy

The basic theory of upconversion is presented, along with a brief historical summary of upconversion techniques. Upconverters were used in astronomical studies, but have met with only modest success. Upconversion will become a useful detection method for astronomy only if substantial but perhaps forseeable, improvements can be realized.

Boyd, R. W.↗

Preliminary study of temperature measurement techniques for Stirling engine reciprocating seals

Methods of determining the contact surface temperature in reciprocating seals are investigated. Direct infrared measurement of surface temperatures of a rod exiting a loaded cap seal or simulated seal are compared with surface thermocouple measurements. Significant cooling of the surface requires several milliseconds so that exit temperatures may be considered representative of internal contact temperatures.

Wilcock, D. F.↗

Precision Lower Stratospheric Temperature Monitoring with the MSU: Technique, Validation, and Results, 1979-1991

Microwave Sounding Unit channel 4 data from the TIROS-N (Television and Infrared Operational Satellite)-N series of NOAA (National Oceanic and Atmospheric Administration) satellites are intercalibrated to provide a continuous global record of deep-layer averaged lower stratospheric temperatures during 1979-1991. A 13-year record of temperature anomalies is time averaged into pentads and months on a 2.5 deg. grid. The monthly gridpoint anomalies are validated with ten years of radiosonde data during 1979-88. The calibration stability of each satellite's measurements is evaluated during satellite overlap periods, the longest of which reveal no measurable instrumental drift at the level of 0.01 C yr (exp -1). Intercomparisons between NOAA-6 and NOAA- 7 anomalies indicate monthly gridpoint precision of 0.05 C in the tropics to around 0.10 C in the extratropics, and signal-to-noise ratios precision and stability statistics are much better than have been previously reported by other investigators for MSU channel 4. Pentad precision is about 0.10 C in the tropics to around 0.25 C at high latitudes and signal-to- noise ratios generally over 250 in the tropics and high latitudes, but 100-200 in the middle latitudes. Radiosonde comparisons to the monthly gridpoint anomalies have correlations ranging from 0.90 in the tropics (where the interannual variability is smallest) to as high as 0.99 at high-latitude stations. The corresponding standard error of estimate is generally around 0.3 C. A significant difference in decadal trends is found between the satellite and radiosonde systems, with a step change of 0.21 C (sondes cooler) compared to the satellite measurements. Investigations of the possible sources of the discrepancy lead us to suspect that the gradual transition from on-site calibration of sondes with thermometers to factory calibration of sondes around 1982 might have caused a change in the calibration, although this conclusion must be viewed as tentative. The largest globally averaged temperature variations during 1979-91 occur after the El Chichon (1982) and Pinatubo (1991) volcanic eruptions. These warm events are superimposed upon a net downward trend in temperatures during the period. This cooling trend has more of a step function than linear character, with the step occurring during the El Chichon warm event. It is strongest in polar regions and the Northern Hemisphere middle latitudes. These characteristics are qualitatively consistent with radiative adjustments expected to occur with observed ozone depletions.

Spencer, Roy W.↗