Search NASA⌕ Search

SEARCH · Search NASA

Results for “LINAC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Development of stripper options for FRIB

The US Department of Energy Facility for Rare Isotope Beams (FRIB) at Michigan State University includes a heavy ion superconducting linac capable of accelerating all ions up to uranium with energies higher than 200 MeV/u and beam power up to 400 kW. To achieve these goals with present ion source performance it is necessary to accelerate simultaneously two charge states of uranium from the ion source in the first section of the linac. At an energy of approximately 16.5 MeV/u it is planned to strip the uranium beam to reduce the voltage needed in the rest of the linac to achieve the final energy. Up to five different charge states are planned to be accelerated simultaneously after the stripper. The design of the stripper is a challenging problem due to the high power deposited (approximately 0.7 kW) in the stripper media by the beam in a small spot. To assure success of the project we have established a research and development program that includes several options: carbon or diamond foils, liquid lithium films, gas strippers and plasma strippers. We present in this paper the status of the different options.

43 PARTICLE ACCELERATORS↗

Multiple bunch HOM evaluation for ERL cavities

In this paper we investigate the effect of the bunch pattern in a linac on the Higher Order Mode (HOM) power generation. The future ERL-based electron–ion collider eRHIC at BNL is used as an illustrative example. This ERL has multiple high current Superconducting Radiofrequency (SRF) 5-cell cavities. The HOM power generated when a single bunch traverses the cavity is estimated by the corresponding loss factor. Multiple re-circulations through the Energy Recovery Linac (ERL) create a specific bunch pattern. In this case the loss factor can be different than the single bunch loss factor. HOM power can vary dramatically when the ERL bunch pattern changes. The HOM power generation can be surveyed in the time and frequency domains. We estimate the average HOM power in a 5-cell cavity with different ERL bunch patterns.

43 PARTICLE ACCELERATORS↗

Bi-resonant klynac

Here in this work, we present the first analysis of a new device called the bi-resonant klynac, which is a combined klystron and linac. In a bi-resonant klynac, all RF cells, except for the cell that acts as the input for the klystron section, belong to a single resonant circuit. This resonant coupling configuration leads to increased operational stability and can tolerate significant temperature variations. In this paper, a basic analysis of this device is presented, including discussions of how it operates and of the advantages of resonantly coupling the RF generation directly to the linac. We additionally describe the approach used to numerically model the klynac and we include detailed simulations of a 50-kV, 10-A klynac that produces a 1-MeV, 0.1-A output beam. In conclusion, this type of device may be especially useful for situations where an electron beam is needed at low cost.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radioisotope replacement with compact electron linear accelerators

The replacement of radioactive sources with alternative technologies has been identified as a priority by international authorities, due to the risk of accidents and diversion by terrorists for use in Radiological Dispersal Devices. Many of these sources can be replaced with the X-rays produced by electron beams accelerated to MeV energies. However, the size, weight and costs of electron linacs must be significantly reduced to be considered for radioisotope replacement. RadiaBeam Technologies, LLC is developing a series of inexpensive compact electron accelerators in the 1–10 MeV range for radioisotope replacement such as Ir-192, Cs-137 and Co-60 for various applications. The dramatic level of miniaturization and cost-reduction was achieved thanks to the implementation of such innovative technologies as high-frequency magnetrons, split accelerating structure fabrication technology and solid-state Marx modulators. Here, in this paper, we overview RadiaBeam's compact linac developments, discuss the enabling technologies, and report on the current progress.

43 PARTICLE ACCELERATORS↗

Particle simulation for direct plasma injection in a radio frequency quadrupole matching section

We have been investigating direct plasma injection scheme (DPIS) for high-intensity heavy-ion beam acceleration. In the DPIS, laser-produced plasma is directly injected into a radio frequency quadrupole (RFQ) linac. To study the beam dynamics of the ion injection in the DPIS, we tracked particle motions in the RFQ matching section using three-dimensional particle-in-cell method. As a result of the numerical simulation, we found that the electrostatic field generated by the extraction electrode reduces the transmission efficiency. To avoid the radially defocusing force, the input beam into the RFQ has to be initially convergent. In the DPIS, further optimization of the plasma density is required for better matching.

43 PARTICLE ACCELERATORS↗

Recent Progress at the Photon Factory Storage Ring

The present status of the Photon Factory storage ring (PF ring) at High Energy Accelerator Research Organization (KEK), including recent progress for the machine developments, is reported. Due to the establishment of the simultaneous injection to the three rings (PF, HER, LER) from the KEK injector linac since April 2009, the PF ring currently operates almost all the time in a top-up mode available to users at a stored current of 450 mA in multi-bunch mode, and at a stored current of 51 mA in single-bunch mode, except the time while the KEK linac injection to the PF-AR twice daily. The third in-vacuum short gap undulator was installed at PF ring in September 2009.

43 PARTICLE ACCELERATORS↗

Experimental study of new laser-based alignment system at the KEK B-factory injector linear accelerator

A new laser-based alignment system for the precise alignment of accelerator components along an ideal straight line at the KEK B-factory injector linear accelerator (linac) is under development. This system is strongly required in the next generation of B-factories for the stable acceleration of high-brightness electron and positron beams with high bunch charges and also for maintaining the stability of injection beams with high quality. A new laser optics for the generation of a so-called Airy beam has been developed for the laser-based alignment system. The laser propagation characteristics both in vacuum and at atmospheric pressure have been systematically investigated in an 82-m-long straight section of the injector linac. The laser-based alignment measurements based on the new laser optics have been carried out with a measurement resolution of {+-}0.1 mm level by using an existing laser detection electronics. The horizontal and vertical displacements from a reference laser line measured using this system are in good agreement with those measured using a standard telescope-based optical alignment technique. In this report, we describe the experimental study in detail along with the basic designs and the recent developments in the new laser-based alignment system.

43 PARTICLE ACCELERATORS↗

H{sup -} radio frequency source development at the Spallation Neutron Source

The Spallation Neutron Source (SNS) now routinely operates nearly 1 MW of beam power on target with a highly persistent {approx}38 mA peak current in the linac and an availability of {approx}90%. H{sup -} beam pulses ({approx}1 ms, 60 Hz) are produced by a Cs-enhanced, multicusp ion source closely coupled with an electrostatic low energy beam transport (LEBT), which focuses the 65 kV beam into a radio frequency quadrupole accelerator. The source plasma is generated by RF excitation (2 MHz, {approx}60 kW) of a copper antenna that has been encased with a thickness of {approx}0.7 mm of porcelain enamel and immersed into the plasma chamber. The ion source and LEBT normally have a combined availability of {approx}99%. Recent increases in duty-factor and RF power have made antenna failures a leading cause of downtime. This report first identifies the physical mechanism of antenna failure from a statistical inspection of {approx}75 antennas which ran at the SNS, scanning electron microscopy studies of antenna surface, and cross sectional cuts and analysis of calorimetric heating measurements. Failure mitigation efforts are then described which include modifying the antenna geometry and our acceptance/installation criteria. Progress and status of the development of the SNS external antenna source, a long-term solution to the internal antenna problem, are then discussed. Currently, this source is capable of delivering comparable beam currents to the baseline source to the SNS and, an earlier version, has briefly demonstrated unanalyzed currents up to {approx}100 mA (1 ms, 60 Hz) on the test stand. In particular, this paper discusses plasma ignition (dc and RF plasma guns), antenna reliability, magnet overheating, and insufficient beam persistence.

43 PARTICLE ACCELERATORS↗

Improvements to the internal and external antenna H{sup −} ion sources at the Spallation Neutron Source

The Spallation Neutron Source (SNS), a large scale neutron production facility, routinely operates with 30–40 mA peak current in the linac. Recent measurements have shown that our RF-driven internal antenna, Cs-enhanced, multi-cusp ion sources injects ∼55 mA of H{sup −} beam current (∼1 ms, 60 Hz) at 65-kV into a Radio Frequency Quadrupole (RFQ) accelerator through a closely coupled electrostatic Low-Energy Beam Transport system. Over the last several years a decrease in RFQ transmission and issues with internal antennas has stimulated source development at the SNS both for the internal and external antenna ion sources. This report discusses progress in improving internal antenna reliability, H{sup −} yield improvements which resulted from modifications to the outlet aperture assembly (applicable to both internal and external antenna sources) and studies made of the long standing problem of beam persistence with the external antenna source. The current status of the external antenna ion source will also be presented.

43 PARTICLE ACCELERATORS↗

The status of the SNS external antenna ion source and spare RFQ test facility

The Oak Ridge National Laboratory operates the Spallation Neutron Source, consisting of a H{sup −} ion source, a 1 GeV linac and an accumulator ring. The accumulated <1 μs-long, ∼35 A beam pulses are extracted from the ring at 60 Hz and directed onto a liquid Hg target. Spalled neutrons are directed to ∼20 world class instruments. Currently, the facility operates routinely with ∼1.2 MW of average beam power, which soon will be raised to 1.4 MW. A future upgrade with a second target station calls for raising the power to 2.8 MW. This paper describes the status of two accelerator components expected to play important roles in achieving these goals: a recently acquired RFQ accelerator and the external antenna ion source. Currently, the RFQ is being conditioned in a newly constructed 2.5 MeV Integrated Test Facility (ITF) and the external antenna source is also being tested on a separate test stand. This paper presents the results of experiments and the testing of these systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The ATLAS multi-user upgrade and potential applications

With the recent integration of the CARIBU-EBIS charge breeder into the ATLAS accelerator system to provide for more pure and efficient charge breeding of radioactive beams, a multi-user upgrade of the ATLAS facility is being proposed to serve multiple users simultaneously. ATLAS was the first superconducting ion linac in the world and is the US DOE low-energy Nuclear Physics National User Facility. The proposed upgrade will take advantage of the continuous-wave nature of ATLAS and the pulsed nature of the EBIS charge breeder in order to simultaneously accelerate two beams with very close mass-to-charge ratios; one stable from the existing ECR ion source and one radioactive from the newly commissioned EBIS charge breeder. In addition to enhancing the nuclear physics program, beam extraction at different points along the linac will open up the opportunity for other potential applications; for instance, material irradiation studies at ~ 1 MeV/u and isotope production at ~ 6 MeV/u or at the full ATLAS energy of ~ 15 MeV/u. Furthermore, the concept and proposed implementation of the ATLAS multi-user upgrade will be presented. Future plans to enhance the flexibility of this upgrade will also be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

KLYNAC: Compact linear accelerator with integrated power supply

Accelerators and accelerator-based light sources have a wide range of applications in science, engineering technology and medicine. Today the scienti c community is working towards improving the quality of the accelerated beam and its parameters while trying to develop technology for reducing accelerator size. This work describes a design of a compact linear accelerator (linac) prototype, resonant Klynac device, which is a combined linear accelerator and its power supply - klystron. The intended purpose of a Klynac device is to provide a compact and inexpensive alternative to a conventional 1 to 6 MeV accelerator, which typically requires a separate RF source, an accelerator itself and all the associated hardware. Because the Klynac is a single structure, it has the potential to be much less sensitive to temperature variations than a system with separate klystron and linac. We start by introducing a simpli ed theoretical model for a Klynac device. We then demonstrate how a prototype is designed step-by-step using particle-in-cell simulation studies for mono- resonant and bi-resonant structures. Finally, we discuss design options from a stability point of view and required input power as well as behavior of competing modes for the actual built device.

43 PARTICLE ACCELERATORS↗

Preliminary Design of a LAMP DTL

A preliminary Drift Tube Linac (DTL) layout was designed to create an algorithm for developing the conceptual design of the proposed LANSCE Accelerator Modernization Project (LAMP) final section: the proton linear accelerator from 3 MeV to 100 MeV. Preceding reports describe the proposed layouts of the LEBT, the RFQ, and the MEBT subsections of the linac. Initial estimates of the needed RF power for the DTL are also presented in the report. Present report describes the initial layout of the DTL and the first longitudinal beam dynamics results of the simulations n simplified models. The follow-up reports will include the transverse focusing scheme and beam dynamics in details. Present report in the last section will only describe the planned focusing scheme, based on the existing LANCE DTL.

43 PARTICLE ACCELERATORS↗

Preliminary Design of a LAMP DTL (Update)

Present report is a continuation of the previously published report LA-UR-23-26600 from 19-Jun-2023 and incorporates the mentioned report as its part. All the additional information is contained in the part III of this report, the DTL Transverse Focusing Scheme. A preliminary Drift Tube Linac (DTL) layout was designed to create an algorithm for developing the conceptual design of the proposed LANSCE Accelerator Modernization Project (LAMP) final section: the proton linear accelerator from 3 MeV to 100 MeV. Preceding reports describe the proposed layouts of the LEBT, the RFQ, and the MEBT subsections of the linac. Initial estimates of the needed RF power for the DTL are also presented in the report. Present report describes the initial layout of the DTL and the first longitudinal beam dynamics (BD) results of the simulations in simplified models. The part III of this report includes the transverse focusing scheme and transverse BD in details.

43 PARTICLE ACCELERATORS↗

Ion colliders

Ion colliders are research tools for high-energy nuclear physics, and are used to test the theory of Quantum Chromo Dynamics (QCD). The collisions of fully stripped high-energy ions create matter of a temperature and density that existed only microseconds after the Big Bang. Ion colliders can reach higher densities and temperatures than fixed target experiments although at a much lower luminosity. The first ion collider was the CERN Intersecting Storage Ring (ISR), which collided light ions [77Asb1, 81Bou1]. The BNL Relativistic Heavy Ion Collider (RHIC) is in operation since 2000 and has collided a number of species at numerous energies. The CERN Large Hadron Collider (LHC) started the heavy ion program in 2010. Table 1 shows all previous and the currently planned running modes for ISR, RHIC, and LHC. All three machines also collide protons, which are spin-polarized in RHIC. Ion colliders differ from proton or antiproton colliders in a number of ways: the preparation of the ions in the source and the pre-injector chain is limited by other effects than for protons; frequent changes in the collision energy and particle species, including asymmetric species, are typical; and the interaction of ions with each other and accelerator components is different from protons, which has implications for collision products, collimation, the beam dump, and intercepting instrumentation devices such a profile monitors. In the preparation for the collider use the charge state Z of the ions is successively increased to minimize the effects of space charge, intrabeam scattering (IBS), charge change effects (electron capture and stripping), and ion-impact desorption after beam loss. Low charge states reduce space charge, intrabeam scattering, and electron capture effects. High charge states reduce electron stripping, and make bending and acceleration more effective. Electron stripping at higher energies is generally more efficient. Table 2 shows the charge states and energies in the RHIC and LHC injector chains for the heaviest ion species used to date. The RHIC pulsed sputter source (PSC) and Tandem electrostatic accelerator are being replaced by an Electron Beam Ion Source (EBIS), Radio Frequency Quadrupole (RFQ) and short linac [08Ale1]. With EBIS beams of any element can be prepared for RHIC including uranium and spin-polarized 3He. At CERN an ECR ion source is used, followed by an RFQ and Linac. The ions are then accumulated, electron cooled, and accelerated in LEIR. After transfer to and acceleration in the PS, ion beams are injected into the SPS.

43 PARTICLE ACCELERATORS↗

Radiography Capabilities for Matter-Radiation Interactions in Extremes

The Matter-Radiation Interactions in Extremes (MaRIE) experimental facility will be used to discover and design the advanced materials needed to meet 21st century national security and energy security challenges. This new facility will provide the new tools scientists need to develop next-generation materials that will perform predictably and on-demand for currently unattainable lifetimes in extreme environments. The MaRIE facility is based on upgrades to the existing LANSCE 800-MeV proton linac and a new 12-GeV electron linac and associated X-ray FEL to provide simultaneous multiple probe beams, and new experimental areas. In addition to the high-energy photon probe beam, both electron and proton radiography capabilities will be available at the MaRIE facility. Recently, detailed radiography system studies have been performed to develop conceptual layouts of high-magnification electron and proton radiography systems that can meet the experimental requirements for the expected first experiments to be performed at the facility. A description of the radiography systems, their performance requirements, and a proposed facility layout are presented.

43 PARTICLE ACCELERATORS↗

Claudio Pellegrini and the World’s First Hard X-ray Free-Electron Laser

President Obama welcomed SLAC's Claudio Pellegrini inside the Oval Office on Tuesday morning as a recipient of the Enrico Fermi Award, one of the highest honors the U.S. government can give to a scientist. Pellegrini, a visiting scientist and consulting professor at SLAC and distinguished professor emeritus at the University of California, Los Angeles, received the award for research that aided in the development of X-ray free-electron lasers (XFELs) including SLAC's Linac Coherent Light Source (LCLS), a DOE Office of Science User Facility that started up in 2009. Here, Pellegrini describes his efforts that contributed to the realization of SLAC’s Linac Coherent Light Source, the world’s first hard X-ray free-electron laser.

43 PARTICLE ACCELERATORS↗

Small scale electron linear accelerators for industrial applications

Linear accelerators (linacs), producing electron or X-ray radiation in the MeV range, are critical tools for industrial irradiation, medical device sterilization, food pasteurization, non-destructive testing, security, medical, and many other applications. Many of these applications require compact and flexible radiation sources. In this paper, we present new technologies for small-scale electron linear accelerators and examples of their practical implementations. Furthermore, these developments include low energy accelerators with self-shielding options and form factors, ranging from cabinet-size to hand-portable generators; medium-energy accelerators for novel radiotherapy and security applications; and high-energy 10 MeV linacs capable of reaching 20–35 kW beam power for emerging industrial and phytosanitary applications

43 PARTICLE ACCELERATORS↗