Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron Experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Pulse Shape Discrimination in JSNS 2

JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment that is searching for sterile neutrinos via the observation of $\overline{ν}$ μ → $\overline{ν}$ e appearance oscillations using neutrinos from muon decay-at-rest. For this search, rejecting cosmic-ray-induced neutron events by Pulse Shape Discrimination (PSD) is essential because the JSNS2 detector is located above ground, on the third floor of the building. We have achieved 94.95% ± 0.15% rejection of neutron events while keeping 92.82% ± 1.77% of signal, electron-like events using a data-driven likelihood method. This article will report the PSD technique using the full fiducial volume of the JSNS2 detector.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

C$^{7}$LYC: A New Scintillator for Fast Neutron Spectroscopy

The scintillator Cs 2 LiYCl 6 (CLYC) has emerged as a versatile detector for both gammas and neutrons, with excellent pulse shape discrimination. Originally developed as a thermal neutron counter, the discovery of its unexpected and unprecedented ~10% pulse height resolution for fast neutrons in the few MeV range has prompted studies to benchmark its use in low-energy nuclear science and applications. Since the typical long time-of-flight arms are not needed for achieving good energy resolution, geometrical efficiency can be enhanced by positioning the detectors much closer to the target. We have constructed a 16-element array of 1” × 1”7Li-enriched C 7 LYC, to eliminate the dominant peak in the spectrum from thermal neutron capture on 6Li, leaving the energy region above 3 MeV with a clean baseline for fast neutron spectroscopy. We have also procured the first ever 3” × 3” C 7 LYC crystal. Test experiments under way with C 7 LYC include elastic and inelastic neutron scattering cross sections at Los Alamos with a pulsed white neutron source, efficiency measurements using mono-energetic neutron beams up to a few MeV at UMass Lowell, and fission neutron measurements with GRETINA and CHICO detector arrays at Argonne. Beta-delayed neutron spectroscopy experiments have also been initiated at the CARIBU and NSCL facilities, to evaluate C 7 LYC as a possible candidate for auxiliary scintillator arrays for stopped beam physics at the next generation rare isotope accelerators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Weapons Radiochemistry: Trinity and Beyond

On July 16, 1945, the Trinity nuclear test exploded in the desert near Alamogordo, New Mexico. A variety of new diagnostic experiments were fielded in an effort to understand the detailed performance of the nuclear device. This paper describes a series of radiochemical experiments that were designed to measure the efficiency and neutron fluence of the test. These experiments, and the scientists who led them, laid the foundation of weapons radiochemistry for decades to come.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

MEASUREMENT OF THE NEUTRON FLUENCE-RATES IN THE ADVANCED TEST REACTOR

The axial neutron fluence-rate distribution at the Advanced Test Reactor (ATR) is determined using a combination of pure nickel and cobalt-aluminium alloy dosimeter wires. Most irradiation programs at ATR need to know the fast neutron fluence-rate surrounding their experiment to correlate post-irradiation examination results with neutron dose. The activated dosimeter wires, which extend beyond the full fuelled region of the reactor core, are highly radioactive following the full cycle in ATR and must therefore be measured in the ATR canal. The system that is employed for these measurements is mechanical scanning mechanism is used to scan the activated wires across the face of a columnated shield and a NaI detector. This detector is not sufficiently calibrated to provide absolute activity measurements, therefore, the count-rate is recorded and normalized to the highest activity for that wire. Then, an approximately 3-mm long portion of the wire is removed from the highest activity region in the wire. The wires are then transferred, and an absolute activity measurement is made using a calibrated ionization chamber. These measurements are combined with corrections for decay, neutron energy spectrum, burnup, dosimeter composition, reactor power fluctuations, and reactor outages to determine the average axial neutron fluence-rate at various locations within ATR during the cycle.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

From Existing and New Nuclear and Astrophysical Constraints to Stringent Limits on the Equation of State of Neutron-Rich Dense Matter

Through continuous progress in nuclear theory and experiment and an increasing number of neutron-star (NS) observations, a multitude of information about the equation of state (EOS) for matter at extreme densities is available. To constrain the EOS across its entire density range, this information needs to be combined consistently. However, the impact and model dependency of individual observations vary. Given their growing number, assessing the various methods is crucial to compare the respective effects on the EOS and discover potential biases. For this purpose, we present a broad compendium of different constraints and apply them individually to a large set of EOS candidates within a Bayesian framework. Specifically, we explore different ways of how chiral effective field theory and perturbative quantum chromodynamics can be used to place a likelihood on EOS candidates. We also investigate the impact of nuclear experimental constraints, as well as different radio and x-ray observations of NS masses and radii. This is augmented by reanalyses of the existing data from binary neutron star coalescences, in particular of GW170817, with improved models for the tidal waveform and kilonova light curves, which we also utilize to construct a tight upper limit of 2.39 M ⊙ on the TOV mass based on GW170817’s remnant. Our diverse set of constraints is eventually combined to obtain stringent limits on NS properties. We organize the combination in a way to distinguish between constraints where the systematic uncertainties are deemed small and those that rely on less conservative assumptions. For the former, we find the radius of the canonical 1.4 M ⊙ neutron star to be R 1.4 = 12.2 6 − 0.91 + 0.80 km and the TOV mass at M TOV = 2.2 5 − 0.22 + 0.42 M ⊙ (95% credibility). Including all the presented constraints yields R 1.4 = 12.2 0 − 0.48 + 0.50 km and M TOV = 2.3 0 − 0.20 + 0.07 M ⊙ . When comparing these limits to individual data points, we find that the quoted radius of HESS J1731-347 displays noticeable tension with other constraints. Constraining microphysical properties of the EOS proves more challenging. For instance, the symmetry energy slope is restricted to L sym = 48 − 25 + 21 MeV , where this constraint is mainly dominated by our reanalysis of the PREX-II and CREX experiment. Published by the American Physical Society 2025

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Integral Experiment Request 554 CED-1 Summary Report

This Critical Engineering Decision 1 report for the Integral Experiment Request 554 describes the effects of adding a commercially available neutron absorber material to a known light-water low-enriched uranium assembly. The assembly in question is the Seven Percent Critical Experiments at Sandia National Laboratories. The neutron absorber plates considered for the experiment are called Boralcan, which are made of boron carbide (B 4 C) particles embedded in 1100 aluminum alloy. The concentrations of B 4 C and 1100 aluminum, as well as the thickness and size of the plates, were changed, and the fuel rod configuration was adapted to ensure that the assembly would be critical in each case studied. A total of 10 critical configurations with a neutron absorber plate inserted are described in this report. No results of high-quality integral experiments involving neutron absorbers made with B 4 C and 1100 aluminum plates are currently publicly available. Sensitivity to the neutron absorber plate material definition, isotopes, and cross sections of specific regions and configurations are also analyzed. The study results indicate that these experiments are achievable with sufficiently low uncertainties and minimal modification to the assembly. The experimental uncertainty can be further decreased with an additional characterization of the plates by x-ray computerized tomography or neutron radiography methods.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantum transport equation for systems with rough surfaces and its application to ultracold neutrons in a quantizing gravity field

We discuss transport of particles along random rough surfaces in quantum size effect conditions. As an intriguing application, we analyze gravitationally quantized ultracold neutrons in rough waveguides in conjunction with GRANIT experiments (ILL, Grenoble). We present a theoretical description of these experiments in the biased diffusion approximation for neutron mirrors with both one- and two-dimensional (1D and 2D) roughness. All system parameters collapse into a single constant which determines the depletion times for the gravitational quantum states and the exit neutron count. This constant is determined by a complicated integral of the correlation function (CF) of surface roughness. The reliable identification of this CF is always hindered by the presence of long fluctuation-driven correlation tails in finite-size samples. We report numerical experiments relevant for the identification of roughness of a new GRANIT waveguide and make predictions for ongoing experiments. We also propose a radically new design for the rough waveguide.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determination of the parahydrogen fraction in a liquid hydrogen target using energy-dependent slow neutron transmission

In this study, the NPDGamma collaboration is performing a measurement of the very small parity-violating asymmetry in the angular distribution of the 2.2 MeV γ-rays from the capture of polarized cold neutrons on protons (A γ ). The estimated size of A γ is 5×10 -8 , and the measured asymmetry is proportional to the neutron polarization upon capture. Since the interaction of polarized neutrons with one of the two hydrogen molecular states (orthohydrogen) can lead to neutron spin-flip scattering, it is essential that the hydrogen in the target is mostly in the molecular state that will not depolarize the neutrons (≥99.8% parahydrogen). For that purpose, in the first stage of the NPDGamma experiment at the Los Alamos Neutron Science Center (LANSCE), we operated a 16-l liquid hydrogen target, which was filled in two different occasions. The parahydrogen fraction in the target was accurately determined in situ by relative neutron transmission measurements. The result of these measurements indicate that the fraction of parahydrogen in equilibrium was 0.9998±0.0002 in the first data taking run and 0.9956±0.0002 in the second. We describe the parahydrogen monitor system, relevant aspects of the hydrogen target, and the procedure to determine the fraction of parahydrogen in the target. In addition, assuming thermal equilibrium of the target, we extract the scattering cross-section for neutrons on parahydrogen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity Upgrades to the Idaho Accelerator Center Neutron Time of Flight Spectrometer

Past experiments have shown that discrimination between between fissionable and non-fissionable materials is possible using an interrogation technique that monitors for high energy prompt fission neutrons. Several recent upgrades have been made to the neutron time of flight spectrometer at the Idaho Accelerator Center with the intent of increasing neutron detection sensitivity, allowing for system use in nonproliferation and security applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resonant neutron scattering lengths

Unlike most of the periodic table, many rare-earth elements display considerable resonant scattering for thermal neutrons. Although this property is accompanied by strong neutron absorption, modern high-intensity neutron sources make diffraction experiments possible with these elements. Computation of scattering intensities is accomplished by fitting the variation in resonant scattering lengths ( b 0 , b ′ and b ′′) to a semi-empirical Breit–Wigner formalism, which can be evaluated over the range of neutron energies useful for diffraction, typically E = 10–600 meV; λ = 0.4–2.8 Å (with good extrapolation to longer wavelengths).

Von Dreele, Robert B. (ORCID:0000000253390634)↗

Reactor Engineering: Experimental Investigation of Alpha Convection

This report summarizes the progress on DE-FG07-07ID14806 project funded by the US Department of Energy under Nuclear Engineering Education Research (NEER) program. During the project a test apparatus was designed and manufactured for experimental investigation of Alpha Convection. Benchmark testing of the new apparatus without the neutron radiation was performed and numerical simulations were conducted to validate the experimental results on natural convection. These results were reported in a journal publication. Subsequently, we conducted the experiment at Missouri S&T research reactor in the beam port to investigate the phenomenon of Alpha Convection. Unfortunately, these experiments were inconclusive. No observable effect of neutron beam was noticed. Insufficient neutron flux as it passes through the borated water is responsible for the unsuccessful experiments. A number of new experiments are designed and manufactured to investigate the phenomenon. A new experiment using shadowgraphy is designed and manufactured to investigate and visualize the natural convection and the impact of neutron on the phenomenon. Moreover, to continue with the original and newly designed experiments a neutron generator was needed to supply a vertical beam of neutrons. This new source of neutron is acquired using DOE NEUP General Scientific Infrastructure number DE-FOA-0000321. The new facility is installed and tested but is yet to be licensed by NRC for regular use and continuation of the experiments.

Conduction convection transition.↗

Adsorption and molecular siting of CO 2 , water, and other gases in the superhydrophobic, flexible pores of FMOF-1 from experiment and simulation

FMOF-1 is a flexible, superhydrophobic metal–organic framework with a network of channels and side pockets decorated with –CF 3 groups. CO 2 adsorption isotherms measured between 278 and 313 K and up to 55 bar reveal a maximum uptake of ca. 6.16 mol kg –1 (11.0 mol L –1 ) and unusual isotherm shapes at the higher temperatures, suggesting framework expansion. We used neutron diffraction and molecular simulations to investigate the framework expansion behaviour and the accessibility of the small pockets to N 2 , O 2 , and CO 2 . Neutron diffraction in situ experiments on the crystalline powder show that CO 2 molecules are favourably adsorbed at three distinct adsorption sites in the large channels of FMOF-1 and cannot access the small pockets in FMOF-1 at 290 K and oversaturated pressure at 61 bar. Stepped adsorption isotherms for N 2 and O 2 at 77 K can be explained by combining Monte Carlo simulations in several different crystal structures of FMOF-1 obtained from neutron and X-ray diffraction under different conditions. A similar analysis is successful for CO 2 adsorption at 278 and 283 K up to ca. 30 bar; however, at 298 K and pressures above 30 bar, the results suggest even more substantial expansion of the FMOF-1 framework. The measured contact angle for water on an FMOF-1 pellet is 158°, demonstrating superhydrophobicity. Simulations and adsorption measurements also show that FMOF-1 is hydrophobic and water is not adsorbed in FMOF-1 at room temperature. Simulated mixture isotherms of CO 2 in the presence of 80% relative humidity predict that water does not influence the CO 2 adsorption in FMOF-1, suggesting that hydrophobic MOFs could hold promise for CO 2 capture from humid gas streams.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Visualizing MCNP Tally Segment Geometry and Coupling Results with ABAQUS

The Advanced Graphite Creep test, AGC-1, is planned for irradiation in the Advanced Test Reactor (ATR) in support of the Next Generation Nuclear Plant program. The experiment requires very detailed neutronics and thermal hydraulics analyses to show compliance with programmatic and ATR safety requirements. The MCNP model used for the neutronics analysis required hundreds of tally regions to provide the desired detail. A method for visualizing the hundreds of tally region geometries and the tally region results in 3 dimensions has been created to support the AGC-1 irradiation. Additionally, a method was created which would allow ABAQUS to access the results directly for the thermal analysis of the AGC-1 experiment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The new cold neutron chopper spectrometer at the Spallation Neutron Source: Design and performance

The design and performance of the new cold neutron chopper spectrometer (CNCS) at the Spallation Neutron Source in Oak Ridge are described. CNCS is a direct-geometry inelastic time-of-flight spectrometer, designed essentially to cover the same energy and momentum transfer ranges as IN5 at ILL, LET at ISIS, DCS at NIST, TOFTOF at FRM-II, AMATERAS at J-PARC, PHAROS at LANSCE, and NEAT at HZB, at similar energy resolution. Measured values of key figures such as neutron flux at sample position and energy resolution are compared between measurements and ray tracing Monte Carlo simulations, and good agreement (better than 20% of absolute numbers) has been achieved. The instrument performs very well in the cold and thermal neutron energy ranges, and promises to become a workhorse for the neutron scattering community for quasielastic and inelastic scattering experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutronic Tests of Fluoride Salt Based MSR/FHR Coolants

Research on molten salt reactor (MSR) technology based on fluoride salts as a convenient way of higher actinides incineration and/or utilization of thorium fuel has been performed at UJV Rez and later Research Centre Rez in Czech Republic since 1999. Necessary steps towards to the deployment and possible commercialization were examined in past investigations. Neutronic testing is an inseparable part of the development and was at first carried out in a series of experiments with LiF-NaF salt (60 mol% LiF, 40 mol% NaF) subjected to a neutron field shaped by different moderators within the framework of the EROS experiments. Later, neutron spectrum was measured in this salt and significant variations in calculation to experiment C/E comparison were discovered. Further tests were performed with Flibe (66 mol% LiF, 33 mol% BeF{sub 2}) reactor coolant salt containing enriched lithium (99.994 mol% Li-7), which was provided by Oak Ridge National Laboratory (ORNL). This Flibe salt originally comes from the Molten Salt Reactor Experiment (MSRE) and was supplied to the Czech Republic within the framework of a collaborative agreement on MSR and fluoride-salt-cooled high-temperature reactor (FHR) research and development (R and D) concluded between the Czech Ministry of Industry and Trade and US Department of Energy in 2012. All experiments in this work were carried out at the LR-0 reactor at Research Centre Rez. The LR-0 is a pool-type zero power light water reactor with large and flexible experimental capabilities due to its design and fuel construction.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Biomembranes research using thermal and cold neutrons

In 1932 James Chadwick discovered the neutron using a polonium source and a beryllium target (Chadwick, 1932). In a letter to Niels Bohr dated February 24, 1932, Chadwick wrote: “whatever the radiation from Be may be, it has most remarkable properties.” Where it concerns hydrogen-rich biological materials, the “most remarkable” property is the neutron’s differential sensitivity for hydrogen and its isotope deuterium. Such differential sensitivity is unique to neutron scattering, which unlike X-ray scattering, arises from nuclear forces. Consequently, the coherent neutron scattering length can experience a dramatic change in magnitude and phase as a result of resonance scattering, imparting sensitivity to both light and heavy atoms, and in favorable cases to their isotopic variants. Furthermore, this article describes recent biomembranes research using a variety of neutron scattering techniques.

59 BASIC BIOLOGICAL SCIENCES↗