Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operational Reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Cryogenic control system operational experience at SNS

Abstract The helium cryogenic system at Spallation Neutron Source (SNS) provides cooling to 81 superconducting radio frequency cavities. To support the operation of the cryogenic facility, a highly reliable control system consisting of software, hardware, and Human Machine Interface (HMI) has been developed and improved during the first fifteen years of operation. Integrating the cryogenic control system with other subsystems of the SNS complex is an important aspect to the success of the operation. The operating experience, lessons learned and recommendations to consider for future facilities will be detailed in this paper.

Howell, M. (ORCID:0000000310360707)↗

Direct Mapping of Charge Distribution during Lithiation of Ge Nanowires Using Off-Axis Electron Holography

The successful operation of rechargeable batteries relies on reliable insertion/ extraction of ions into/from the electrodes. The battery performance and the response of the electrodes to such ion insertion and extraction are directly related to the spatial distribution of the charge and its dynamic evolution. However, it remains unclear how charge is distributed in the electrodes during normal battery operation. In this work, we have used offaxis electron holography to measure charge distribution during lithium ion insertion into a Ge nanowire (NW) under dynamic operating conditions. We discovered that the surface region of the Ge core is negatively charged during the core-shell lithiation of the Ge NW, which is counterbalanced by positive charge on the inner surface of the lithiated LixGe shell. The remainder of the lithiated LixGe shell is free from net charge, consistent with its metallic characteristics. The present work provides a vivid picture of charge distribution and dynamic evolution during Ge NW lithiation and should form the basis for tackling the response of these and related materials under real electrochemical conditions.

25 ENERGY STORAGE↗

Materials Characterization using the Facilities of the Center for Synchrotron Radiation Research and Instrumentation (CSRRI), a NSUF Partner Facility

Advanced nuclear energy systems are envisioned to operate at high temperatures, high burn-up, harsh neutron irradiation, and corrosive environments. New materials and nuclear fuels with improved performance, safety and reliability are needed for the increasingly demanding operating conditions. The fundamental challenge in developing new materials with improved irradiation, temperature, and corrosion resistance is to understand and control chemical and physical phenomena in complex systems over multiple time and length scales. Solving these scientific and technical challenges will require an integrated approach of all available computational and experimental capabilities. This talk will focus on the application of synchrotron radiation techniques to characterize materials of interest to nuclear material science at the facilities operated by the Center For Synchrotron Radiation Research and Instrumentation (CSRRI) at the Illinois Institute of Technology. The CSRRI is a partner facility with the U. S. Department of Energy's Nuclear Science User Facility (NSUF). Using the CSRRI facilities, such as the Materials Research Collaborative Access Team (MRCAT) beamline, we can study the materials science of irradiated and model materials to improve the understanding of the performance of materials in nuclear reactors. (author)

36 MATERIALS SCIENCE↗

Enhanced Component Performance Study: Air-Operated Valves 1998–2012

This report presents an enhanced performance evaluation of air-operated valves (AOVs) at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience failure reports from fiscal year 1998 through 2012 for the component reliability as reported in the Equipment Performance and Information Exchange (EPIX). Results (beta distributions for failure probabilities upon demand and gamma distributions for rates) are used as inputs to the U.S. Nuclear Regulatory Commission standardized plant analysis risk models of U.S. commercial nuclear power plants. The AOV failure modes considered are failure-to-open/close, failure to operate or control, and spurious operation. The component reliability estimates and the reliability data are trended for the most recent 10-year period while yearly estimates for reliability are provided for the entire active period. No statistically significant increasing trends were identified in the AOV results. Statistically significant decreasing trends were identified in two areas: AOV operation demands less than or equal to 20 demands per year and greater than 20 demands.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Increasing the Reliability, Service Life, and Ecological Safety of the Stuffing Boxes of Wellhead Equipment of Wells that Operate by Means of Deep-Well Sucker-Rod Pumping Units

A novel design of an axial (self-centering) blowout prevention well-head seal that eliminates a number of the drawbacks in the wellhead equipment which is used today and whicuh possesses high services qualities, reliability indicators, and service life is proposed. The design is protected by Russian Patent No. 2573887.

42 ENGINEERING↗

Policies Get Smart

Successfully achieving a smart electric infrastructure that delivers reliability and quality in today’s operating environment demands more than just good technology. Utlities are faced with growing demand and increased carbon constraints. To help mitigate these market conditions, deployment of a smart electic infrastructure is needed. Regulatory support, consumer acceptance and industry leadership are critical to the deployment of this smart electric infrastructure that can deliver reliable power under increased system constraints.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Air Corrosivity in U.S. Outdoor-Air-Cooled Data Centers is Similar to That in Conventional Data Centers

There is a concern that environmental-contamination caused corrosion may negatively affect Information Technology (IT) equipment reliability. Nineteen data centers in the United States and two in India were evaluated using Corrosion Classification Coupons (CCC) to assess environmental air quality as it may relate IT equipment reliability. The data centers were of two basic types: closed and outside-air cooled. A closed data center provides cool air to the IT equipment using air conditioning in which only a small percent age of the recirculation air is make-up air continuously supplied from outside to meet human health requirements. An outside-air cooled data center uses outside air directly as the primary source for IT equipment cooling. Corrosion measuring coupons containing copper and silver metal strips were placed in both closed and outside-air cooled data centers. The coupons were placed at each data center (closed and outside-air cooled types) with the location categorized into three groups: (1) Outside - coupons sheltered, located near or at the supply air inlet, but located before any filtering, (2) Supply - starting just after initial air filtering continuing inside the plenums and ducts feeding the data center rooms, and (3) Inside located inside the data center rooms near the IT equipment. Each coupon was exposed for thirty days and then sent to a laboratory for a corrosion rate measurement analysis. The goal of this research was to investigate whether gaseous contamination is a concern for U.S. data center operators as it relates to the reliability of IT equipment. More specifically, should there be an increased concern if outside air for IT equipment cooling is used To begin to answer this question limited exploratory measurements of corrosion rates in operating data centers in various locations were undertaken. This study sought to answer the following questions: (1) What is the precision of the measurements (2) What are the approximate statistical distributions of copper and silver corrosion rates in the sampled data centers(3) To what extent are copper and silver corrosion measurements related (4) What is the relationship of corrosion rate measurements between outside-air cooled data centers compared to closed data centers (5) How do corrosivity measurements relate to IT equipment failure rates The data from our limited sample size suggests that most United States data center operators should not be concerned with environmental gaseous contamination causing high IT equipment failure rates even when using outside-air cooling. The research team recommends additional basic research on how environmental conditions, specifically gaseous contamination, affect electronic equipment reliability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Root Causes of Field Emitters in SRF Cavities Placed in CEBAF Tunnel

It has been suspected that appearance of new field emitters can occur in SRF cavities after their placement in accelerator tunnel for long term beam operation. This apparently has been the case for CEBAF. However, no physical evidence has been shown in the past. In this contribution, we will report on the recent results concerning the root cause of field emitters in SRF cavities placed in CEBAF tunnel. We will discuss these results in the context of high-reliability and low-cryogenic-loss operation of CEBAF.

Geng, Rongli↗

Optimal Power Flow Pursuit

Past works that focused on addressing power-quality and reliability concerns related to renewable energy resources (RESs) operating with business-as-usual practices have looked at the design of Volt/VAr and Volt/Watt strategies to regulate real or reactive powers based on local voltage measurements, so that terminal voltages are within acceptable levels. These control strategies have the potential of operating at the same time scale of distribution-system dynamics, and can therefore mitigate disturbances precipitated fast time-varying loads and ambient conditions; however, they do not necessarily guarantee system-level optimality, and stability claims are mainly based on empirical evidences. On a different time scale, centralized and distributed optimal power flow (OPF) algorithms have been proposed to compute optimal steady-state inverter setpoints, so that power losses and voltage deviations are minimized and economic benefits to end-users providing ancillary services are maximized. However, traditional OPF schemes may offer decision making capabilities that do not match the dynamics of distribution systems. Particularly, during the time required to collect data from all the nodes of the network (e.g., loads), solve the OPF, and subsequently dispatch setpoints, the underlying load, ambient, and network conditions may have already changed; in this case, the DER output powers would be consistently regulated around outdated setpoints, leading to suboptimal system operation and violation of relevant electrical limits. The present work focuses on the synthesis of distributed RES-inverter controllers that leverage the opportunities for fast feedback offered by power-electronics interfaced RESs. The overarching objective is to bridge the temporal gap between long-term system optimization and real-time control, to enable seamless RES integration in large scale with stability and efficiency guarantees, while congruently pursuing system-level optimization objectives. The design of the control framework is based on suitable linear approximations of the AC power-flow equations as well as Lagrangian regularization methods. The proposed controllers enable an update of the power outputs at a time scale that is compatible with the underlying dynamics of loads and ambient conditions, and continuously drive the system operation towards OPF-based solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

U.S. Laws and Regulations for Renewable Energy Grid Interconnections

Rapidly declining costs of wind and solar energy technologies, increasing concerns about the environmental and climate change impacts of fossil fuels, and sustained investment in renewable energy projects all point to a not-so-distant future in which renewable energy plays a pivotal role in the electric power system of the 21st century. In light of public pressures and market factors that hasten the transition towards a low-carbon system, power system planners and regulators are preparing to integrate higher levels of variable renewable generation into the grid. Updating the regulations that govern generator interconnections and operations is crucial to ensure system reliability while creating an enabling environment for renewable energy development. This report presents a chronological review of energy laws and regulations concerning grid interconnection procedures in the United States, highlighting the consequences of policies for renewable energy interconnections. Where appropriate, this report places interconnection policies and their impacts on renewable energy within the broader context of power market reform.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Design and Field Testing of Manufacturable Advanced Low-Cost Receiver for Parabolic Trough Solar Power

This project addresses the 30-yr service life, ease of manufacturability for low cost, and low Operations and Maintenance (O&M) costs for our novel parabolic trough receiver, SunTrap. Current trough-based commercial power plants operate at 400°C or below, in part due to poor performance and lifetime of existing receivers at higher temperatures. Thermal losses from such receivers are dominated by radiation; by the Stefan- Boltzmann law, radiative losses have a component that scales as T 4, challenging high-temperature efficiency. Our novel SunTrap receiver offers increased reliability by eliminating the need to operate in a vacuum, while improving performance at higher temperatures by using high-performance insulation on exposed sections of the receiver that absorb negligible solar flux. As a result, SunTrap offers comparable optical efficiency to currently available technology while reducing thermal losses at higher temperatures. In this project, our novel receiver and all subcomponents have been designed to be compatible with molten salts to enable operation at next generation trough-based exit temperatures between 500 and 550°C. Norwich Technologies, with collaborators from Creare, Thermodyne, Solar Dynamics (previously Abengoa Solar), and the University of Louisiana – Lafayette successfully iterated the design of the SunTrap receiver through a series of modelling efforts, cost analyses, prototype builds, and performance and lifetime tests to minimize the levelized cost of energy (LCOE). The final design (1) realized predicted receiver performance in a series of field optical efficiency, laboratory thermal efficiency and freeze/thaw recovery tests, (2) optimized the receiver with respect to integration with standard collector systems, receiver-to-receiver connections, and receiver-to-mirror connections, (3) demonstrated 30-yr service life of receiver and all components of the receiver, (4) developed commercialization and manufacturing plans to enable rapid deployment, and (5) demonstrated durability of an air-stable solar-selective coating. NT’s disruptive technology marshals diverse advances in design, materials and coatings to revolutionize key aspects of the CSP trough solar field. By enabling significant operational and cost advances, this technology offers potential decreases in LCOE of over 20% compared to traditional parabolic trough systems.

14 SOLAR ENERGY↗

The Shortwave Spectral Radiometer for Atmospheric Science: Capabilities and Applications from the ARM User Facility

Industry advances have greatly reduced the cost and size of ground-based shortwave (SW) sensors for the ultraviolet, visible, and near-infrared spectral ranges that make up the solar spectrum, while simultaneously increasing their ruggedness, reliability, and calibration accuracy needed for outdoor operation. These sensors and collocated meteorological equipment are an important part of the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) User Facility, which has supported parallel integrated measurements of atmospheric and surface properties for more than two decades at fixed and mobile sites around the world. The versatile capability of these ground-based measurements includes 1) rich spectral information required for retrieving cloud and aerosol microphysical properties, such as cloud phase, cloud particle size, and aerosol size distributions, and 2) high temporal resolution needed for capturing fast evolution of cloud microphysical properties in response to rapid changes in meteorological conditions. Here we describe examples of how ARM's spectral radiation measurements are being used to improve understanding of the complex processes governing microphysical, optical, and radiative properties of clouds and aerosol.

54 ENVIRONMENTAL SCIENCES↗

An Operational Resilience Metric for Modern Power Distribution Systems

The electrical power system is the backbone of our nations critical infrastructure. It has been designed to withstand single component failures based on a set of reliability metrics which have proven acceptable during normal operating conditions. However, in recent years there has been an increasing frequency of extreme weather events. Many have resulted in widespread long-term power outages, proving reliability metrics alone do not provide adequate energy security. As a result, researchers have focused their efforts on a new set of metrics based on the concept of resilience to ensure efficient operation of power systems during extreme events. A resilient system has the ability to resist, adapt, and recover from disruptions. Therefore, resilience has demonstrated itself as a promising concept for currently faced challenges in power distribution systems. In this work, we propose a real-time resilience metric for modern power distribution systems. The metric is an aggregation of the controllable assets adaptive capacity, or their temporal flexibility in real and reactive power. This metric gives information to the magnitude and duration of a disturbance which the system can respond to without having to drop loads or have stability issues in voltage or frequency. We demonstrate the impact to resilience in a case study under normal operation and during a power contingency on a microgrid. In the future, this information can be used by operators to make more informed decisions based on system resilience in an effort to prevent power outages.

42 ENGINEERING↗

Use of Systems Engineering in Repurposing Coal-Fired Power Plants with Malta Pumped Thermal Energy Storage System

he electric sector across North America is facing a transition. Both economics and policy decisions have pointed towards a broad retirement of fossil assets across markets. Owners are facing the problem of how to evolve the base of the electric sector from fossil asset to greener alternative. Coal-fired power plants built the modern electricity grid. Their rotating machinery are the beating heart of the grid, providing essential resiliency and reliability services. Power plant retirements are disruptive to plant workforces and cause outsized impacts on surrounding communities. The transition from thermal power plants that use rotating machinery to generate electricity (e.g., coal- and gas-fired plants) to variable, inverter-based generation (e.g., solar and wind) is affecting the reliability of the electric grid. Grid operators and national regulators have issued warnings about known and anticipated risk. In 2021, Malta Inc. was awarded a Department of Energy (DOE) grant to study how to integrate a Malta 100MW Pumped Heat Energy Storage (PHES) system with a retiring coal-fired power plant to meet emissions requirements, retain plant workforces, preserve communities, and maintain grid reliability. This presentation provides a summary of this study, focusing on how systems engineering approach was used to arrive at a proposed design concept that met multiple objectives and requirements. There will be three main parts for this presentation. The first part of the presentation will focus on how different systems engineering was applied for this work. In particular, the following areas: stakeholder engagement, site selection process, developing requirements and use cases for the integrated system, defining the system and its boundary, coming up with different system architecture/option, performing a techno-economic analysis to compare the different options and down selection of the preferred option, will be discusses. For these areas, discussion on the decisions on how much breadth and depth to go into each area will be provided. These discussions provide good insights into how to apply systems engineering. The second part of the presentation will provide a deeper dive into the two recommended integration options that repurpose coal-fired power plants with Malta PHES system. The comparison of the two options and general guidance of how to choose an option will be provided. This is particularly useful for utilities who are facing coal-plant retirements. The two options will be compared based on its performance (such as power output, efficiency), complexity, and cost. The social impact on local communities of the two options will also be discussed. The final part of the presentation will discuss the impact that this work has had, including Malta Inc. being invited to the White House to discuss progress and outcomes of this work with the Interagency Working Group on Coal and Power Plant Communities and Economic Revitalization. In summary, this presentation aims to provide a showcase of how sy

25 ENERGY STORAGE↗

Aging Assessment of an Oak Ridge National Laboratory High Flux Isotope Reactor (HFIR) Service Cable

Nuclear energy is one industry where aging of safety-related materials and components is of great concern. Many U.S. nuclear power plants are approaching, or have already exceeded, 40 years of age. Analysis comparing the cost of new plant construction versus long-term operation under extended plant licensing through 60 years strongly favors the latter option. To ensure the safe, reliable, and cost-effective long-term operation of nuclear power plants, many systems, structures, and components must be evaluated. Furthermore, as new analytical techniques and testing approaches are developed, it is imperative that we also validate, and if necessary, improve upon the previously employed Institute of Electrical and Electronic Engineers (IEEE) qualification standards originally written in 1974. Fortunately, this daunting task has global support, particularly in light of the new social and political climate surrounding nuclear energy in a post-Fukushima era.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Nonconvex Robust Optimization for the Design and Operation of Advanced Energy Systems Using PyROS

This work discusses recent advances of the two-stage robust optimization (RO) solver PyROS and applications to advanced energy systems optimization. To demonstrate the computational performance and reliability of PyROS, a study on a monoethanolamine (MEA)-based CO2 absorption flowsheet is presented. (Near-)robust feasible designs for CO2 absorption flowsheet at high carbon capture are obtained with the PyROS solver. The results demonstrate that the PyROS solver, including recent extensions to multi-stage RO settings, provides a reliable avenue to optimize the design and operation of advanced energy systems subject to various sources of parametric uncertainty.

Sherman, Jason↗

Evaluation of Reformer Produced Synthesis Gas for Emissions Reductions in Natural Gas Reciprocating Engines

Rolls-Royce Fuel Cell Systems (US) Inc. (RRFCS) has developed a system that produces synthesis gas from air and natural gas. A near-term application being considered for this technology is synthesis gas injection into reciprocating engines for reducing NOx emissions. A proof of concept study using bottled synthesis gas and a two-stroke reciprocating engine showed that injecting small amounts of highflammables content synthesis gas significantly improved combustion stability and enabled leaner engine operation resulting in over 44% reduction in NOx emissions. The actual NOx reduction that could be achieved in the field is expected to be engine specific, and in many cases may be even greater. RRFCS demonstrated that its synthesis gas generator could produce synthesis gas with the flammables content that was successfully used in the engine testing. An economic analysis of the synthesis gas approach estimates that its initial capital cost and yearly operating cost are less than half that of a competing NOx reduction technology, Selective Catalytic Reduction. The next step in developing the technology is an integrated test of the synthesis gas generator with an engine to obtain reliability data for system components and to confirm operating cost. RRFCS is actively pursuing opportunities to perform the integrated test. A successful integrated test would demonstrate the technology as a low-cost option to reduce NOx emissions from approximately 6,000 existing two-stroke, natural gas-fired reciprocating engines used on natural gas pipelines in North America. NOx emissions reduction made possible at a reasonable price by this synthesis gas technology, if implemented on 25% of these engines, would be on the order of 25,000 tons/year.

03 NATURAL GAS↗

Operation of the H- Linac at FNAL

The Fermi National Accelerator Laboratory (FNAL) Linac has been in operation for 52 years. In approximately four years, it will be replaced by a new 800 MeV superconducting machine, the PIP-II SRF Linac. In the current configuration, the Linac delivers H- ions at 400 MeV and injects protons by charge exchange into the Booster synchrotron. Despite its age, the Linac is the most stable accelerator in the FNAL complex, reliably sending 22 mA in daily operations. We will discuss the status of the operation, beam studies, and plans.

43 PARTICLE ACCELERATORS↗