Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHASE IMAGING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Investigating the use of in situ liquid cell scanning transmission electron microscopy

Engineering nanoparticles with desired shape-dependent properties is the key to many applications in nanotechnology. Although many synthetic procedures exist to produce anisotropic gold nanoparticles, the dynamics of growth are typically unknown or hypothetical. In the case of seed-mediated growth in the presence of DNA into anisotropic nanoparticles, it is not known exactly how DNA directs growth into specific morphologies. A series of preliminary experiments were carried out to contribute to the investigation of the possible mechanism of DNA-mediated growth of gold nanoprisms into gold nanostars using liquid cell scanning transmission electron microscopy (STEM). Imaging in the liquid phase was achieved through the use of a liquid cell platform and liquid cell holder that allow the sample to be contained within a “chip sandwich” between two electron transparent windows. Ex situ growth experiments were performed using Au-T30 NPrisms (30-base thymine oligonucleotide-coated gold nanoprisms) that are expected to grow into gold nanostars. Growth to form these nanostars were imaged using TEM (transmission electron microscopy) and liquid cell STEM (scanning transmission electron microscopy). An attempt to perform in situ growth experiments with the same Au-T30 nanoprisms revealed challenges in obtaining desired morphology results due to the environmental differences within the liquid cell compared to the ex situ environment. Different parameters in the experimental method were explored including fluid line set up, simultaneous and alternating reagent addition, and the effect of different liquid cell volumes to ensure adequate flow of reagents into the liquid cell. Lastly, the binding affinities were compared for T30 and A30 DNA incubated with gold nanoparticles using zeta potential measurements, absorption spectroscopy, and isothermal titration calorimetry (ITC). It was previously reported thymine bases have a lower binding affinity to gold surfaces than adenine bases. However, the results reported here contradict the previously reported data. Future prospectives on this work are outlined.

36 MATERIALS SCIENCE↗

Photometric imaging of Mars during the 1973 opposition

The paper discusses imaging of Mars at 20 wavelengths in the spectral region from 0.35 to 1.10 microns performed during the 1973 opposition with a photometric imaging system that uses a silicon vidicon tube as the detector. The imaging system and data-reduction procedures are described in detail, and relative reflectance spectra for several small areas in the images are presented along with vidicon images obtained during early phases in the development of the 1973 dust storms. Several anomalous blue brightenings are examined and attributed to ground fog and H2O frost. It is suggested that anomalously large amounts of H2O were pulsed into the atmosphere from the regolith by the storm system. An apparent fading and recession of the north polar hood is noted, surface units revealed in contrast-enhanced ratio images are identified, and the need for higher-spatial-resolution orbital spectroscopy of dark areas is emphasized.

Mccord, T. B.↗

Motion detection, novelty filtering, and target tracking using an interferometric technique with a GaAs phase conjugate mirror

A method and apparatus is disclosed for detecting and tracking moving objects in a noise environment cluttered with fast-and slow-moving objects and other time-varying background. A pair of phase conjugate light beams carrying the same spatial information commonly cancel each other out through an image subtraction process in a phase conjugate interferometer, wherein gratings are formed in a fast photo-refractive phase conjugate mirror material. In the steady state, there is no output. When the optical path of one of the two phase conjugate beams is suddenly changed, the return beam loses its phase conjugate nature and the inter-ferometer is out of balance, resulting in an observable output. The observable output lasts until the phase conjugate nature of the beam has recovered. The observable time of the output signal is roughly equal to the formation time of the grating. If the optical path changing time is slower than the formation time, the change of optical path becomes unobservable, because the index grating can follow the change. Thus, objects traveling at speeds which result in a path changing time which is slower than the formation time are not observable and do not clutter the output image view.

Cheng, Li-Jen↗

Motion detection, novelty filtering, and target tracking using an interferometric technique with GaAs phase conjugate mirror

A method and apparatus for detecting and tracking moving objects in a noise environment cluttered with fast- and slow-moving objects and other time-varying background. A pair of phase conjugate light beams carrying the same spatial information commonly cancel each other out through an image subtraction process in a phase conjugate interferometer, wherein gratings are formed in a fast photorefractive phase conjugate mirror material. In the steady state, there is no output. When the optical path of one of the two phase conjugate beams is suddenly changed, the return beam loses its phase conjugate nature and the interferometer is out of balance, resulting in an observable output. The observable output lasts until the phase conjugate nature of the beam has recovered. The observable time of the output signal is roughly equal to the formation time of the grating. If the optical path changing time is slower than the formation time, the change of optical path becomes unobservable, because the index grating can follow the change. Thus, objects traveling at speeds which result in a path changing time which is slower than the formation time are not observable and do not clutter the output image view.

Cheng, Li-Jen↗

PIV Measurements of a Low-noise Top-mounted Propulsion Installation for a Supersonic Airliner

A model-scale exhaust system was tested to validate low-noise propulsion concepts and noise prediction methods. The tests involved far-field acoustics, phased array, and particle image velocimetry (PIV). This paper covers the particle image velocimetry portion. Data was acquired at NASA Glenn's Aero-Acoustic Propulsion Lab for a series of nozzles with different chevron designs, both uninstalled and installed on a representative aircraft planform. The impact of the various chevron treatments on the turbulent velocity field was documented, along with the impact of the pylon and planform. When correlated with far-field acoustic measurements and phased array measurements, reported in companion papers, the explanation of acoustic benefits from top-mounted propulsion is clear as is the path toward optimization of the concept.

Propulsion Airframe Integration↗

The application of cinematic rendering to CT evaluation of upper tract urothelial tumors: principles and practice

Upper tract urothelial carcinoma (UTUC) is a relatively uncommon but aggressive genitourinary malignancy for which multi-phase contrast-enhanced computed tomography (CT) plays an important role in evaluation and staging. 3D imaging with maximum intensity projection (MIP) and volume-rendered (VR) images has been described as a useful means of evaluating UTUC. In this study, we describe the technique of a novel 3D methodology known as cinematic rendering (CR) and provide clinical examples of UTUC visualized with CR. CR utilizes a complex universal lighting model in order to create photorealistic images with improved detail and depth in comparison to MIP or VR images. In the case of UTUC, CR can be used in different contrast phases to show abnormally thickened and enhancing urothelium or filling defects in the renal collecting system or ureters in the excretory phase. CR images can also be manipulated in order to generate translucent views of the upper urinary tract in order to add conspicuity to intraluminal findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Jet formation in cerium metal to examine material strength

Examining the evolution of material properties at extreme conditions advances our understanding of numerous high-pressure phenomena from natural events like meteorite impacts to general solid mechanics and fluid flow behavior. Recent advances in synchrotron diagnostics coupled with dynamic compression platforms have introduced new possibilities for examining in-situ, spatially resolved material response with nanosecond time resolution. In this work, we examined jet formation from a Richtmyer-Meshkov instability in cerium initially shocked into a transient, high-pressure phase, and then released to a low-pressure, higher-temperature state. Cerium's rich phase diagram allows us to study the yield stress following a shock induced solid-solid phase transition. X-ray imaging was used to obtain images of jet formation and evolution with 2–3 μm spatial resolution. From these images, an analytic method was used to estimate the post-shock yield stress, and these results were compared to continuum calculations that incorporated an experimentally validated equation-of-state (EOS) for cerium coupled with a deviatoric strength model. Reasonable agreement was observed between the calculations and the data illustrating the sensitivity of jet formation on the yield stress values. The data and analysis shown here provide insight into material strength during dynamic loading which is expected to aid in the development of strength aware multi-phase EOS required to predict the response of matter at extreme conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Entanglement Enabled Intensity Interferometry of different wavelengths of light

Highlights: • We use quantum entanglement to erase the color of photons for a new imaging method. • Can achieve higher resolution imaging by accessing hidden phase information. • We detail practical experimental designs to implement our theoretical protocols. We propose methods to perform intensity interferometry of photons having two different wavelengths. Distinguishable particles typically cannot interfere with each other, but we overcome that obstacle by processing the particles via entanglement and projection so that they lead to the same final state at the detection apparatus. Specifically, we discuss how quasi-phase-matched nonlinear crystals can be used to convert a quantum superposition of light of different wavelengths onto a common wavelength, while preserving the phase information essential for their meaningful interference. We thereby gain access to a host of new observables, which can probe subtle frequency correlations and entanglement. Further, we generalize the van Cittert–Zernike formula for the intensity interferometry of extended sources, demonstrate how our proposal supports enhanced resolution of sources with different spectral character, and suggest potential applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Polar Cap Area and Boundary Motion During Substorms

The area of the polar cap as a function of local time and substorm phase was measured using images from the Polar Ultraviolet Imager (UVI) for different interplanetary magnetic field (IMF) orientations during three substorms in January 1997. We measured changes in the polar cap area and motion of the poleward and equatorward boundary of the auroral oval as determined by UVI images. It was found that the polar cap boundary is strongly influenced by thinning of the oval, decrease in polar cap structures, the poleward expansion of the substorm at midnight and the fading of luminosity below the instrument sensitivity threshold. Generally these effects dominate over the latitudinal motion of the auroral oval at its equatorward edge. A new feature is that the polar cap region clears of precipitation during the substorm growth phase, which expands the size of the polar cap but may not necessarily be related to an expansion of the open flux. We present a new finding that the increase in polar cap area prior to onset and the decrease in the area following it are independent of the strength of the southward IMF component. For one case the polar cap area increased while the southward component of the IMF was no less than -0.5 nT. These observations have strong implications for models that use the polar cap area to estimate the magnitude of energy storage in the lobe magnetic field and loss during substorms.

Brittnacher, M.↗

Breast tumor segmentation in high resolution x-ray phase contrast analyzer based computed tomography

Purpose: Phase contrast computed tomography has emerged as an imaging method, which is able to outperform present day clinical mammography in breast tumor visualization while maintaining an equivalent average dose. To this day, no segmentation technique takes into account the specificity of the phase contrast signal. In this study, the authors propose a new mathematical framework for human-guided breast tumor segmentation. This method has been applied to high-resolution images of excised human organs, each of several gigabytes. Methods: The authors present a segmentation procedure based on the viscous watershed transform and demonstrate the efficacy of this method on analyzer based phase contrast images. The segmentation of tumors inside two full human breasts is then shown as an example of this procedure’s possible applications. Results: A correct and precise identification of the tumor boundaries was obtained and confirmed by manual contouring performed independently by four experienced radiologists. Conclusions: The authors demonstrate that applying the watershed viscous transform allows them to perform the segmentation of tumors in high-resolution x-ray analyzer based phase contrast breast computed tomography images. Combining the additional information provided by the segmentation procedure with the already high definition of morphological details and tissue boundaries offered by phase contrast imaging techniques, will represent a valuable multistep procedure to be used in future medical diagnostic applications.

60 APPLIED LIFE SCIENCES↗

High resolution imaging at Palomar

For the last two years we have embarked on a program of understanding the ultimate limits of ground-based optical imaging. We have designed and fabricated a camera specifically for high resolution imaging. This camera has now been pressed into service at the prime focus of the Hale 5 m telescope. We have concentrated on two techniques: the Non-Redundant Masking (NRM) and Weigelt's Fully Filled Aperture (FFA) method. The former is the optical analog of radio interferometry and the latter is a higher order extension of the Labeyrie autocorrelation method. As in radio Very Long Baseline Interferometry (VLBI), both these techniques essentially measure the closure phase and, hence, true image construction is possible. We have successfully imaged binary stars and asteroids with angular resolution approaching the diffraction limit of the telescope and image quality approaching that of a typical radio VLBI map. In addition, we have carried out analytical and simulation studies to determine the ultimate limits of ground-based optical imaging, the limits of space-based interferometric imaging, and investigated the details of imaging tradeoffs of beam combination in optical interferometers.

Kulkarni, Shrinivas R.↗

Phase retrieval of diffraction from highly strained crystals

An important application of phase retrieval methods is to invert coherent x-ray diffraction measurements to obtain real-space images of nanoscale crystals. The phase information is currently recovered from reciprocal-space amplitude measurements by the application of iterative projective algorithms that solve the nonlinear and nonconvex optimization problem. Various algorithms have been developed each of which apply constraints in real and reciprocal space on the reconstructed object. In general, these methods rely on experimental data that is oversampled above the Nyquist frequency. To date, support-based methods have worked well, but are less successful for highly strained structures, defined as those which contain (real-space) phase information outside the range of {+-}{pi}/2. As a direct result the acquired experimental data is, in general, inadvertently subsampled below the Nyquist frequency. In recent years, a new theory of 'compressive sensing' has emerged, which dictates that an appropriately subsampled (or compressed) signal can be recovered exactly through iterative reconstruction and various routes to minimizing the l{sub 1} norm or total variation in that signal. This has proven effective in solving several classes of convex optimization problems. Here we report on a 'density-modification' phase reconstruction algorithm that applies the principles of compressive sensing to solve the nonconvex phase retrieval problem for highly strained crystalline materials. The application of a nonlinear operator in real-space minimizes the l{sub 1} norm of the amplitude by a promotion-penalization (or 'propenal') operation that confines the density bandwidth. This was found to significantly aid in the reconstruction of highly strained nanocrystals. We show how this method is able to successfully reconstruct phase information that otherwise could not be recovered.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A revolutionary concept to improve the efficiency of IC antennas

The successful design of an Ion Cyclotron (IC) antenna mainly relies on the capability of coupling high power to the plasma (MW), feature that is currently reached by allowing rather high voltages (tens of kV) on the unavoidable unmatched part of the feeding lines. This requirement is often responsible of arcs along the transmission lines and other unwanted phenomena that considerably limit the usage of IC launchers. In this work, we suggest and describe a revolutionary approach based on high impedance surfaces, which allows to increase the antenna radiation efficiency and, hence, to highly reduce the imposed voltages to couple the same level of power to the plasma. High-impedance surfaces are periodic metallic structures (patches) displaced usually on top of a dielectric substrate and grounded by means of vertical posts usually embedded inside a dielectric, in a mushroom-like shape. In terms of working properties, high impedance surfaces are electrically thin in-phase reflectors, i.e. they present a high impedance, within a given frequency band, such that the image currents are in-phase with the currents of the antenna itself, thus determining a significant efficiency increase. While the usual design of a high impedance surface requires the presence of a dielectric layer, some alternative solutions can be realized in vacuum, taking advantage of double layers ofmetallic patches. After an introductory part on the properties of high impedance surfaces, this work documents both their design by means of numerical codes and their implementation on a scaled mock-up.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A revolutionary concept to improve the efficiency of ion cyclotron antennas

The successful design of an ion cyclotron (IC) antenna mainly relies on the capability of coupling high power to the plasma (MW), feature that is currently reached by allowing rather high voltages (tens of kV) on the unavoidable unmatched part of the feeding lines. This requirement is often responsible of arcs along the transmission lines and other unwanted phenomena, such as rectification discharges or hotspots, that considerably limit the usage of IC launchers. In this work, we suggest and describe a revolutionary approach based on high impedance surfaces, which allows to increase the antenna radiation efficiency and, hence, to highly reduce the imposed voltages to couple the same level of power to the plasma. High-impedance surfaces are periodic metallic structures (patches) displaced usually on top of a dielectric substrate and grounded by means of vertical posts usually embedded inside a dielectric, in a mushroom-like shape. In terms of working properties, high impedance surfaces are electrically thin in-phase reflectors, i.e., they present a high impedance, within a given frequency band, such that the image currents are in-phase with the currents of the antenna itself, thus determining a significant efficiency increase. While the usual design of a high impedance surface requires the presence of a dielectric layer, some alternative solutions can be realised in vacuum, taking advantage of double layers of metallic patches. After an introductory part on the properties of high impedance surfaces, this work documents both their design by means of numerical codes and their implementation on a scaled mock-up.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TH-E-17A-09: High Quality and Artifact-Free 4D Cone Beam CT and Its Application in Adaptive Treatment Planning

Purpose: To develop a high quality 4D cone beam CT (4DCBCT) method that is immune to patient/couch truncations and to investigate its application in adaptive replanning of lung XRT. Methods: In this study, IRB-approved human subject CBCT data was acquired using a Varian on-board imager with 1 minute rotation time. The acquired projection data was retrospectively sorted into 20 respiratory phase bins, from which 4DCBCT images with high SNR and high temporal resolution were generated using Prior Image Constrained Compressed Sensing (PICCS). Couch and patient truncations generate strong data inconsistency in the projection data and artifacts in the 4DCBCT image. They were addressed using an adaptive PICCS method. The artifact-free PICCS-4DCBCT images were used to generate adaptive treatment plans for the same patient at the 10th (day 21) and 30th (day 47) fractions. Dosimetric impacts with and without PICCS- 4DCBCT were evaluated by isodose distributions, DVHs, and other dosimetric factors. Results: The adaptive PICCS-4DCBCT method improves image quality by removing residue truncation artifacts; measured universal image quality increased 37%. The isodose lines and DVHs with PICCS-4DCBCT-based adaptive replanning were significantly more conformal to PTV than without replanning due to changes in patient anatomy caused by progress of the treatment. The mean dose to PTV at the 10th fraction was 63.1Gy with replanning and 64.2Gy without replanning, where the prescribed dose was 60Gy, in 2Gy × 30 fractions. The mean dose to PTV at the 30th fraction was 61.6Gy with replanning and 64.9Gy without replanning. Lung V20 was 37.1%, 41.9% and 43.3% for original plan, 10th fraction plan and 30th fraction plan; with re-planning, Lung V20 was 37.1%, 32%, 27.8%. Conclusion: 4DCBCT imaging using adaptive PICCS is able to generate high quality, artifact-free images that potentially can be used to create replanning for improving radiotherapy of the lung. K Niu, K Li, J Smilowitz: Nothing to Disclose. G Chen: General Electric Company Research funded, Siemens AG Research funded, Varian Medical Systems Research funded, Hologic Research funded.

60 APPLIED LIFE SCIENCES↗

Experimentally-Derived Phase Function Approximations in Support of the Orbital Debris Program Office

The NASA Orbital Debris Program Office (ODPO) has used various optical assets to acquire photometric data of Earth-orbiting objects to define the orbital debris environment. To better characterize and model optical data acquired from ground-based telescopes, the Optical Measurements Center (OMC) at NASA Johnson Space Center emulates illumination conditions seen in space by using equipment and techniques that parallel telescopic observations and source-target-sensor orientations. One of the OMC goals is to improve the size calculation used for optical data by developing an optical-based Size Estimation Model. The current size estimation requires applying a Lambertian phase function, a set albedo value, and range to the observed magnitude. The first step to improving the sampled brightness of laboratory targets is to remove aspect-angle dependencies. Then, the volume of possible object viewing angles is sampled at 21 combinations of azimuth and elevation angles for each solar phase angle. Finally, the acquired images are input into an image processing program that generates approximations for the object’s Bidirectional Reflectance Distribution Function (BRDF) and phase function. The BRDF is a radiometric concept that identifies an object’s material composition by matching a BRDF approximated with photometric data collected by ground-based telescopes with a BRDF generated experimentally from a known object in the laboratory. This paper presents the initial BRDF and phase function approximations for various fragments/targets acquired in the OMC and how the findings will be incorporated into ODPO models. A Lambertian sphere is used as a baseline for initial size estimation calculations and phase function comparisons. Spacecraft materials and fragments from hypervelocity laboratory impact tests are also presented to compare against the current assumed Lambertian phase function used for size estimates. This paper presents the preliminary phase function analysis and plan forward to utilize a laboratory-based phase function to improve the current optical size estimates using BRDF measurements for a large volume of targets composed of various shapes, sizes, and materials.

Hostetler, J.↗

Topological Defects Coupling Smectic Modulations to Intra–Unit-Cell Nematicity in Cuprates

We study the coexisting smectic modulations and intra-unit-cell nematicity in the pseudogap states of underdoped Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8+{delta}}. By visualizing their spatial components separately, we identified 2{pi} topological defects throughout the phase-fluctuating smectic states. Imaging the locations of large numbers of these topological defects simultaneously with the fluctuations in the intra-unit-cell nematicity revealed strong empirical evidence for a coupling between them. From these observations, we propose a Ginzburg-Landau functional describing this coupling and demonstrate how it can explain the coexistence of the smectic and intra-unit-cell broken symmetries and also correctly predict their interplay at the atomic scale. This theoretical perspective can lead to unraveling the complexities of the phase diagram of cuprate high-critical-temperature superconductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Invasive intraductal papillary mucinous neoplasms of the pancreas: relationships between mural nodules detected on thin-section contrast-enhanced MDCT and invasive components

Purpose: To elucidate the relationships between mural nodules (MNs) and invasive components in patients with invasive intraductal papillary mucinous neoplasm (IPMN) on the basis of thin-section contrast-enhanced multidetector CT (CE-MDCT) and pathologic findings. Methods: This retrospective study included 28 patients with surgically confirmed invasive IPMN. Two radiologists independently evaluated the thin-section (1-mm section thickness, no overlap) triple-phase CE-MDCT images for MNs, invasive components, and the continuity between them using a five-point scale (confidence scores of 1–3 as negative, 4 and 5 as positive). Kappa statistic was used to evaluate interobserver agreement. The CE-MDCT findings were correlated with pathologic findings. Results: Interobserver agreement was good or excellent. MNs consisting of tumor cells were recognized in 12 (42.9%) of 28 patients with no discrepancy between the two radiologists. Invasive components were detected in 85.7% and 82.1% in the pancreatic parenchymal phase for radiologist 1 and 2, respectively, and recognized as hypoattenuating areas. Pathologic continuities between MNs and invasive components were confirmed in five (41.7%) of 12 patients with MNs and these were detected on CE-MDCT. When combined seven patients without continuities between MNs and invasive components and 16 patients without MNs, the invasive components pathologically derived from non-nodular low-height papillary epithelium in 23 (82.1%) of 28 patients. Conclusions: The invasive components derived more often from low-height papillary epithelium without MN appearance on CE-MDCT than from MN. Careful attention should be paid to the existence of an invasive component even in the absence of an enhancing MN.

62 RADIOLOGY AND NUCLEAR MEDICINE↗