Search NASA⌕ Search

SEARCH · Search NASA

Results for “PROGRAM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Superhydrophobic Powder Additives to Enhance Chemical Agent Resistant Coating Systems for Military Equipment for the US Marine Corps (USMC) Corrosion Prevention and Control (CPAC) Program

The primary goal of the CPAC program at ORNL was to explore the feasibility of introducing various silica-based superhydrophobic (SH) powder additives as a way to improve the corrosion resistance of US Department of Defense (DOD) military-grade chemical agent resistant coating (CARC) systems. ORNL had previously developed and patented several SH technologies of interest to the USMC, and one of the objectives of this program was to identify methods to incorporate these technologies into the USMC’s corrosion-resistance strategy. This report discusses findings of the CPAC and their application.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Low-E Retrofit Demonstration and Educational Program

The objective of this project was to demonstrate the capability of low-emissivity (low-E) storm windows / panels and low-E retrofit glazing systems to significantly and cost effectively improve the energy efficiency of both existing residential and commercial buildings. The key outcomes are listed below: RESIDENTIAL CASE STUDIES: (a) A residential case study in two large multifamily apartment buildings in Philadelphia showed a substantial 18-22% reduction in heating energy use and a 9% reduction in cooling energy use by replacing old clear glass storm windows with modern low-E storm windows. Furthermore, the new low-E storm windows reduced the overall apartment air leakage by an average of 10%. (b) Air leakage testing on interior low-E panels installed in a New York City multifamily building over windows with and without AC units showed that the effective leakage area of the windows was reduced by 77-95%. (c) To study the use of low-E storm windows in a warmer mixed climate with a balance of both heating and cooling, 10 older homes near Atlanta with single pane windows were tested with three types of exterior storm windows: clear glass, low-E glass with high solar heat gain, and low-E glass with lower solar heat gain. The storm windows significantly reduced the overall home air leakage by an average of 17%, or 3.7 ACH50. Considerably high variability in the data made it difficult to draw strong conclusions about the overall energy usage, but for heating periods, the low-E storm windows showed approximately 15% heating energy savings, whereas clear storm windows were neutral in performance. For cooling periods, the low-E storm windows showed a wide range of performance from 2% to over 30% cooling energy savings. Overall, the study showed the potential for significantly more energy savings from using low-E glass versus no storm window or clear glass storm windows in warmer mixed climates, but it is difficult to conclusively say whether one type of low-E performed better than the other. COMMERCIAL CASE STUDIES: (a) A 12-story office building in Philadelphia was retrofitted by adding a double-pane low-E insulating glass unit to the existing single pane windows, to create a triple glazed low-E system. A detailed side-by-side comparison in two pairs of perimeter offices facing north and east showed a 39-60% reduction in heating energy use, a 9-36% reduction in cooling energy use, and a 10% reduction in peak electrical cooling demand. An analysis of utility bills estimated the whole building heating and cooling energy use was reduced by over 25%. Additionally, the retrofit window temperatures were commonly 20 degrees warmer on winter days, and 10-20 degrees cooler on summer days, leading to increased occupant comfort. (b) Two large 4-story office buildings in New Jersey were retrofitted with a similar system, but using two low-E coatings in the retrofit system. The energy savings are being monitored by a separate GPIC project; this work quantified the changes in glass surface temperatures, thermal comfort, and potential glass thermal stress. The low-E retrofit panels greatly reduced daily variations in the interior window surface temperatures, lowering the maximum temperature and raising the minimum temperature by over 20F compared to the original single pane windows with window film. The number of hours of potential thermal discomfort, as measured by deviation between mean radiant temperature and ambient air temperature by more than 3F, were reduced by 93 percent on the south orientation and over two-thirds on the west orientation. Overall, the low-E retrofit led to substantially improved occupant comfort with less periods of both overheating and feeling cold. (c) No significant thermal stress was observed in the New Jersey office building test window when using the low-E retrofit system over a variety of weather conditions. The surface temperature difference only exceeded 10F (500 psi thermal stress) for less than 1.5% of the monitored time, and in all cases, the maximum surface temperature difference never exceeded 35F (1,750 psi thermal stress). LOW-E STORM WINDOW OUTREACH AND EDUCATION PROGRAM: (a) The project team assisted the State of Pennsylvania in adding low-E storm windows as a cost effective weatherization measure on its priority list for the state weatherization assistance program. (b) No technical barriers that could hinder widespread application were identified in the case studies. However, educational barriers have been identified, in that weatherization personnel commonly misunderstand how the application of low-E storm windows is very different than much more expensive full window replacement. (c) A package of educational materials was developed to help communicate the benefits of low-E storm windows and retrofits as a cost effective tool for weatherization personnel. (d) Using detailed thermal simulations, more accurate U-factor and solar heat gain coefficient (SHGC) values were determined for low-E storm windows installed over different primary windows. IN SUMMARY, this work confirmed the potential for low-E storm windows, panels, and retrofit systems to provide significant energy savings, reductions in air leakage, and improvements in thermal comfort in both residential and commercial existing buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of Tank 51H (HTF-51-15- 77) Subsurface Supernatant Sample in Support of Enrichment and Corrosion Control Programs

This report provides the results of analyses on Tank 51H subsurface supernatant liquid sample in support of the Enrichment Control Program (ECP) and the Corrosion Control Program (CCP). The purpose of the ECP sample taken from Tank 51H in early June was to determine if the later decants would be “acceptable feed” to the 2H and 3H evaporator systems.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Tank 51H (HTF-51-15-77) Subsurface Supernatant Sample in Support of Enrichment and Corrosion Control Programs

This report provides the results of analyses on Tank 51H subsurface supernatant liquid sample in support of the Enrichment Control Program (ECP) and the Corrosion Control Program (CCP).The purpose of the ECP sample taken from Tank 51H in early June was to determine if the later decants would be “acceptable feed” to the 2H and 3H evaporator systems.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FY 2009 Annual Progress Report for Advanced Vehicle Technology Analysis and Evaluation Activities and Heavy Vehicle Systems Optimization Program

The AVTAE team’s mission is to evaluate the technologies and performance characteristics of advanced automotive powertrain components and subsystems in an integrated vehicle systems context, covering light to heavy platforms. This work is directed toward evaluating and verifying the targets of the VT technology R&D teams and to providing guidance in establishing roadmaps for achievement of these goals. The prime objective of the AVTAE team activities is to evaluate VT Program targets and associated data that will enable the VT technology R&D teams to focus research on specific technology areas. The areas of interest are technologies that will maximize the potential for fuel efficiency improvements, as well as petroleum displacement, and tailpipe emissions reduction. AVTAE accomplishes this objective through a tight union of computer modeling and simulation, integrated component testing and emulation, and laboratory and field testing of vehicles and systems. AVTAE also supports the VT Program goals of fuel consumption reduction by developing and evaluating vehicle system technologies in the area of vehicle ancillary loads reduction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Wireless Success Story - Industrial Technologies Program (ITP)

This success story presents the results of wireless research by Sensors & Automation, a sub-program of the U.S. Department of Energy (DOE) Industrial Technologies Program (ITP). The prioritized research resulted in success with realized energy and cost savings.

Industry↗

2010 Wind Program Peer Review Report

This report documents the evaluation of the technical, scientific, and business results of over 80 projects of the Wind Program, as well as the productivity and management effectiveness of the Wind Program itself.

17 WIND ENERGY↗

Geothermal Technologies Program Blue Ribbon Panel Recommendations

The Geothermal Technologies Program assembled a geothermal Blue Ribbon Panel on March 22-23, 2011 in Albuquerque, New Mexico for a guided discussion on the future of geothermal energy in the United States and the role of the DOE Program. The Geothermal Blue Ribbon Panel Report captures the discussions and recommendations of the experts. An addendum is available here: http://www.eere.energy.gov/geothermal/pdfs/gtp_blue_ribbon_panel_report_addendum10-2011.pdf

blue ribbon↗

Northwest Energy Efficient Manufactured Housing Program Specification Development

The DOE research team Building America Partnership for Improved Residential Construction (BA-PIRC), Bonneville Power Administration (BPA), and Northwest Energy Works (NEW), the current Northwest Energy Efficient Manufactured Home Program (NEEM) program administrator, collaborated to research a new specification that would reduce the energy requirements of a NEEM home.This research identified and developed combinations of cost-effective high performance building assemblies and mechanical systems that can readily can be deployed in the manufacturing setting that reduce energy used for space conditioning, water heating and lighting by 50% over the present NEEM specifications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2014 Water Power Program Peer Review Report

The Water Power Peer Review Meeting was held February 24-28, 2014 in Arlington, VA. Principle investigators from the Energy Department National Laboratories, academic, and industry representatives presented the progress of their DOE-funded research. This report documents the formal, rigorous evaluation process and findings of nine independent reviewers who examined the technical, scientific, and business results of 96 projects of the Water Power Program, as well as the productivity and management effectiveness of the Water Power Program itself.

13 HYDRO ENERGY↗

FY 2014 Continuation of Solicitation for the Office of Science Financial Assistance Program

On January 28-30, 2014, the National Council for Science and the Environment (NCSE) hosted its 14th National Confrerence and Global Forum on Science, Policy and the Environment: Building Climate Solutions. The conference was held at the Hyatt Regency Crystal City near the Washington, DC National Airport. The conference engaged over 1,100 key individuals from a variety of fields, including natural and social sciences, humanities and engineering and government and policy, as well as business and civil society. They developed actionable partnerships, strategies and tactics that advanced solutions minimizing the impacts of anthropogenic climate change. The conference was organized around the two major areas where climate actions are necessary: [1] The Built Environment; and, [2] Agriculture and Natural Resources. This “multi-sector approach” of the conference enables participants to work across traditional boundaries of discipline, science, policy and application by engaging a diverse team of scientists, public- and private-sector program managers, and policy-makers. The confernce was two and a half days long. During this time, over 200 speakers presented in 8 keynote addresses, 7 plenary roundtable discussions, 30 symposia and 23 workshops. The goal of the workshops was to generate additional action through development of improved strategies, tools, and partnerships. During the workshops, participants developed actionable outcomes, committed to further collaboration and implementation, and outlined follow-up activities for post-conference. A list of recommendations from the workshop follows this summary. NCSE’s annual conference has become a signature event for the organization, recognized for its notable presenters, innovative programming, and outcome-oriented approach. Each year, over 1,100 participants attend the event, representing federal agencies, higher education institutions, state and local governments, non-governmental and civic organizations, businesses, and international entities.

54 ENVIRONMENTAL SCIENCES↗

The Use of Underground Research Laboratories to Support Repository Development Programs. A Roadmap for the Underground Research Facilities Network.

Under the auspices of the International Atomic Energy Agency (IAEA), nationally developed underground research laboratories (URLs) and associated research institutions are being offered for use by other nations. These facilities form an Underground Research Facilities (URF) Network for training in and demonstration of waste disposal technologies and the sharing of knowledge and experience related to geologic repository development, research, and engineering. In order to achieve its objectives, the URF Network regularly sponsors workshops and training events related to the knowledge base that is transferable between existing URL programs and to nations with an interest in developing a new URL. This report describes the role of URLs in the context of a general timeline for repository development. This description includes identification of key phases and activities that contribute to repository development as a repository program evolves from an early research and development phase to later phases such as construction, operations, and closure. This information is cast in the form of a matrix with the entries in this matrix forming the basis of the URF Network roadmap that will be used to identify and plan future workshops and training events.

MacKinnon, Robert J.↗

2014 DOE Hydrogen and Fuel Cells Program Annual Merit Review and Peer Evaluation Report

This report summarizes comments from the Peer Review Panel at the 2014 DOE Hydrogen and Fuel Cells Program Annual Merit Review, held on June 16-20, 2014, in Washington, DC. It covers the program areas of hydrogen production and delivery; hydrogen storage; fuel cells; manufacturing R&D; technology validation; safety, codes, and standards; market transformation; and systems analysis.

amr↗

2011 DOE Hydrogen and Fuel Cells Program Annual Merit Review and Peer Evaluation Report

This report summarizes comments from the Peer Review Panel at the 2011 DOE Hydrogen and Fuel Cells Program Annual Merit Review, held on May 9-13, 2011, in Arlington, Virginia. It covers the program areas of hydrogen production and delivery; hydrogen storage; fuel cells; manufacturing R&D; technology validation; safety, codes, and standards; education; market transformation; and systems analysis.

hydrogen, fuel cell, amr↗

2010 DOE Hydrogen Program Annual Merit Review and Peer Evaluation Report

This report summarizes comments from the Peer Review Panel at the 2010 DOE Hydrogen Program Annual Merit Review, held on June 7-11, 2010, in Washington, DC. It covers the program areas of hydrogen production and delivery; hydrogen storage; fuel cells; manufacturing R&D; technology validation; safety, codes, and standards; education; and systems analysis.

amr↗