Characterization of dangling bond defects at the crystalline Si/SiO x interface in a polycrystalline Si passivating contact solar cell at room temperature with electrically detected magnetic resonance spectroscopy

Monocrystalline silicon solar cells can achieve photoconversion efficiencies exceeding 26%; however, performance-limiting defects that trap carriers continue to be a challenge. In this work, we have characterized Si solar cells with tunneling SiO x /polycrystalline-Si (poly-Si) passivating contacts (TOPCon) on As-doped Czochralski Si wafers with electrically detected magnetic resonance (EDMR) spectroscopy. We fabricated 2 × 20 mm 2 TOPCon-like mini solar cells with edge passivation alongside larger 4 cm 2 sister cells and obtained similar device characteristics. We performed EDMR spectroscopy at 300 K on two minicells with different degrees of surface passivation based on the recombination parameter, J o , values of 40 and 310 fA/cm2. We optimized the resolution and the signal-to-noise ratio of the EDMR response of the minicells by varying the forward bias voltage and the magnetic field modulation amplitude. We detect two distinct signals with EDMR spectroscopy, an axial-like signal at g = 2.009, 2.0087, and 2.0015, and an isotropic signal at g = 2.0024, which we attribute to Si dangling bonds (P b0 and P b centers) and boron–oxygen related defects, respectively, at or near the c-Si/SiO x interface. The EDMR signals were lower for the cell with a lower value of J o , while the ratio of the two defect populations was very similar. The EDMR signal increases with forward bias but drops to zero at bias voltages >0.5 V, consistent with interface defects within or near the boron-doped emitter depletion region. Our study demonstrates a method to fabricate minicells that can be characterized with EDMR spectroscopy to detect industrially relevant defects in TOPCon cells.

14 SOLAR ENERGY↗

Understanding the Mechanism of Light and Elevated Temperature Induced Degradation of p-type Silicon Solar Cells (Final Report)

Light- and elevated-temperature-induced degradation (LeTID) was first discovered in multicrystalline Si (mc-Si) solar cells and was initially attributed to metal impurities. Later, LeTID was reported in Czochralski (Cz) and float-zone (FZ) Si, and is considered as an important efficiency loss mechanism in p-type passivated emitter rear contact (p-PERC) Cz Si solar cells. LeTID causes ~10% relative and permeant efficiency losses in these cells in warmer climate regions where the module temperature is > 50 °C. Unlike light-induced degradation (LID), which is also observed in p-PERC cells, LeTID is slower and takes weeks to months in the field to saturate. Another difference compared to LID is that regeneration in LeTID proceeds very slowly, and field regeneration could take > 25 years — essentially the life of the module. Unlike B-O defects that are responsible for LID, neither B nor O impurities are directly involved in LeTID. LeTID appears to be unique to p-type Si, and is also observed in Ga-doped Si. Currently, most experimental evidence relates LeTID to the injection of hydrogen present in the dielectric surface passivation layers, such as SiN x and Al 2 O 3 , into the monocrystalline Si (c-Si) bulk during the fast-firing step. The involvement of hydrogen is further strengthened by controlled studies that show that increasing the amount of hydrogen in the dielectric during fast-firing increases the degree of LeTID. Similar to LID, a regeneration process has been discovered for LeTID. Regeneration of LeTID defects occurs when samples are exposed to 2–4 Suns illumination at elevated temperatures of 140–220 °C for 2–15 hr. Given the slower kinetics of LeTID and sample regeneration compared to LID, this poses a challenge for the manufacturing and field reliability of p-PERC cells, which will be the leading photovoltaic technologies over the next decade. Therefore, there is a need to understand LeTID and develop strategies to mitigate this effect. The defect responsible for LeTID has been extensively studied with over 100 publications, but direct spectroscopic evidence of this defect’s structure is lacking. Without an atomistic understanding of the LeTID defect, it is difficult to assess the long-term efficacy of the current industrial mitigation strategies. This, in turn, has implications on energy production for tens of gigawatts of these cells that will be deployed yearly worldwide. Using electron paramagnetic resonance, we identified a defect associated with LeTID with a g-value of 2.006, which we attribute to an Si dangling bond in an extended defect such as a vacancy agglomerate with H possibly within or in close vicinity. These vacancy agglomerates are likely created during the firing process, during which time H atoms are also injected into the bulk from the hydrogenated SiN x dielectric layer. Our atomistic-level insight shows that the LeTID defect can be mitigated by targeted intrinsic defect engineering of the c-Si material through a slower pull rate of the Cz ingot or 1000 °C oxygen ambient processing of the Si wafer to reduce the vacancy concentration. This project was a collaborative effort between the Colorado School of Mines and the National Renewable Energy Laboratory.

14 SOLAR ENERGY↗

Spread Spectrum Time Domain Reflectivity for String Monitoring in PV Power Plants (Final Technical Report)

This final report describes the methods and results of applying Spread Spectrum Time Domain Reflectivity (SSTDR) for String Monitoring in PV Power Plants for DE-EE0008169. The project created a new system for both detecting and locating electrical faults in photovoltaic systems. In this work, we address photovoltaic electric faults that are both common and costly. Based on interviews with photovoltaic power plant owners, operators, and maintainers, three types of faults are common and of significant interest: disconnects, ground faults, and arc faults. Disconnects can originate from many sources. They are often due to everyday events, such as lawnmowing (accidentally running over a cable), animals eating through the cables, or degradation that occurs over time due to corrosion or general degradation. Ground faults occur when the cables (for example, due to frayed insolation) connect to the ground, relaying current into the ground. These faults are particularly problematic since the ground faults are often intermittent. That is, ground faults commonly appear during rain storms due to a change in soil conductivity and then disappear when the rain ends. This makes the ground fault difficult to find because while current systems can detect the overall change in voltage and current associated with a ground fault, technicians are necessary to locate the fault. As a result, ground faults may disappear before the technician arrives at the power plant. Hence, locating and fixing ground faults often require multiple trips. We also study arc faults, which can result when nearby conductors create an arc of electrical current through the air. While less common, arc faults can be extremely dangerous. The energetic electrical arc can cause fires and destroy equipment, costing significant damage. Overall all three types of faults cost owners and operators money, either from the destruction of equipment or from technician time. Furthermore, while devices exist for detecting ground faults (ground fault circuit interrupters) and arc faults (arc fault circuit interrupter), these systems only search patterns of electrical current that correspond to each fault. This information cannot be used to locate the fault. In addition, these protection systems experience nuisance trips due to nearby electromagnetic interference, such as from a lawn mower or other motors that produce significant amounts of electromagnetic radiation. Hence, the overall goal of this project is to create an SSTDR tool that provides photovoltaic power plants with more reliable fault detection in addition to the localization of faults. SSTDR works by transmitting electrical signals into the photovoltaic string. Those signals reflect from impedance discontinuities (i.e., disconnects, ground faults, and arc faults). These faults are then detected by measuring the presence of a reflection at the SSTDR and can be located by identifying the location of that reflection in time. In addition, unlike current protection systems, these systems do not experience nuisance trips since their low amplitude, high frequency, and coded signal can by analyzed without interference from the regular operational voltage on the photovoltaic string.

14 SOLAR ENERGY↗