Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

The Impact of Multiple-Site Interactions on the Energy Resolution of a High-Pressure Xenon Gamma-Ray Spectrometer

High-pressure xenon (HPXe) ionization chambers have generated interest as a radiation detection medium for purposes requiring good energy resolution, high detection efficiency, and uniform response over a broad temperature range, such as homeland security and well logging applications. These chambers generally exhibit a substantial degradation of the measured energy resolution relative to theoretical limits. This investigation studies the impact of the number of interaction sites in an event sequence on the measured energy resolution using a benchmarked simulation package. The prominence of single and multiple-site interactions is investigated in addition to the photopeak broadening due to each event class. A radial position-sensing technique developed for coplanar-anode HPXe chambers is shown to have benefit for only single-site events.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Numerical techniques for large cosmological N-body simulations

Techniques for carrying out large N-body simulations of the gravitational evolution of clustering in the fundamental cube of an infinite periodic universe are described and compared. The accuracy of the forces derived from several commonly used particle mesh schemes is examined, showing how submesh resolution can be achieved by including short-range forces between particles by direct summation techniques. The time integration of the equations of motion is discussed, and the accuracy of the codes for various choices of 'time' variable and time step is tested by considering energy conservation as well as by direct analysis of particle trajectories. Methods for generating initial particle positions and velocities corresponding to a growing mode representation of a specified power spectrum of linear density fluctuations are described. The effects of force resolution are studied and different simulation schemes are compared. An algorithm is implemented for generating initial conditions by varying the number of particles, the initial amplitude of density fluctuations, and the initial peculiar velocity field.

Efstathiou, G.↗

Damage Detection System with Sub-microsecond Resolution

Fiber optic grating sensors have been used to measure multi-dimensional strain, pressure, temperature, corrosion and moisture. This paper presents a method of using fiber grating sensors to measure the position and velocity of a very fast event associated with a blast wave. A chirped fiber grating of 50 mm length is placed in a highly energetic material. The action of the shock wave is to destroy the fiber grating as it propagates along it. By using a spectral filter such as a chirped fiber grating in combination with high speed detectors the position and velocity of the shock wave may be determined. A layout of a system used to experimentally verify this technique is described and results presented for two different highly energetic materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The early ALMA view of the FU Ori outburst system

We have obtained ALMA Band 7 observations of the FU Ori outburst system at a 0.″6 × 0.″5 resolution to measure the link between the inner disk instability and the outer disk through submillimeter continuum and molecular line observations. Our observations detect continuum emission that can be well-modeled by two unresolved sources located at the position of each binary component. The interferometric observations recover the entire flux reported in previous single-dish studies, ruling out the presence of a large envelope. Assuming that the dust is optically thin, we derive disk dust masses of 2 × 10{sup −4} M{sub ⊙} and 8×10{sup −5} M{sub ⊙} for the north and south components, respectively. We place limits on the disks’ radii of r < 45 AU. We report the detection of molecular emission from {sup 12}CO(3-2), HCO{sup +}(4-3), and from HCN(4-3). The {sup 12}CO appears widespread across the two binary components and is slightly more extended than the continuum emission. The denser gas tracer HCO{sup +} peaks close to the position of the southern binary component, while HCN appears to be peaked at the position of the northern component. This suggests that the southern binary component is embedded in denser molecular material, consistent with previous studies that indicate a heavily reddened object. At this angular resolution, any interaction between the two unresolved disk components cannot be disentangled. Higher-resolution images are vital for understanding the process of star formation via rapid accretion FU Ori-type episodes.

79 ASTRONOMY AND ASTROPHYSICS↗

Structural Basis of Substrate Recognition in Thiopurine S-Methyltransferase

Thiopurine S-methyltransferase (TPMT) modulates the cytotoxic effects of thiopurine prodrugs such as 6-mercaptopurine by methylating them in a reaction using S-adenosyl-l-methionine as the donor. Patients with TPMT variant allozymes exhibit diminished levels of protein and/or enzyme activity and are at risk for thiopurine drug-induced toxicity. We have determined two crystal structures of murine TPMT, as a binary complex with the product S-adenosyl-l-homocysteine and as a ternary complex with S-adenosyl-l-homocysteine and the substrate 6-mercaptopurine, to 1.8 and 2.0 {angstrom} resolution, respectively. Comparison of the structures reveals that an active site loop becomes ordered upon 6-mercaptopurine binding. The positions of the two ligands are consistent with the expected S{sub N}2 reaction mechanism. Arg147 and Arg221, the only polar amino acids near 6-mercaptopurine, are highlighted as possible participants in substrate deprotonation. To probe whether these residues are important for catalysis, point mutants were prepared in the human enzyme. Substitution of Arg152 (Arg147 in murine TPMT) with glutamic acid decreases V{sub max} and increases K{sub m} for 6-mercaptopurine but not K{sub m} for S-adenosyl-l-methionine. Substitution at this position with alanine or histidine and similar substitutions of Arg226 (Arg221 in murine TPMT) result in no effect on enzyme activity. The double mutant Arg152Ala/Arg226Ala exhibits a decreased V{sub max} and increased K{sub m} for 6-mercaptopurine. These observations suggest that either Arg152 or Arg226 may participate in some fashion in the TPMT reaction, with one residue compensating when the other is altered, and that Arg152 may interact with substrate more directly than Arg226, consistent with observations in the murine TPMT crystal structure.

59 BASIC BIOLOGICAL SCIENCES↗

Assessment of the displacement field along a surface crack in a flat plate using optical techniques

Structural components may contain cracks, and for these components a crack tip represents a highly singular stress. The evaluation of the associated strain gradient is difficult to achieve with experimental discrete methods. An efficient alternative are the optical techniques which are non-contact, and so delivering continuous information of the displacement fields and associated derivatives for strain evaluation. This paper describes some experimental methods to fully characterize the displacement field near a crack tip existing in flat plates. Three optical field techniques based on image analysis were used in the present work; respectively, Electronic Speckle Pattern Interferometry, Moiré Interferometry, and Digital Image Correlation. These methods allow different resolutions which can be adjusted according to the expected strain gradient. While the first method depends on the laser wavelength and position of the illumination sources, the second depends on the grating pitch and the last on the surface texture or painted speckle. Algorithms to derivate and filtering the displacement field are developed to compute the strain field and will be used for further works.

36 MATERIALS SCIENCE↗

CONNECTING THE SUN'S HIGH-RESOLUTION MAGNETIC CARPET TO THE TURBULENT HELIOSPHERE

The solar wind is connected to the Sun's atmosphere by flux tubes that are rooted in an ever-changing pattern of positive and negative magnetic polarities on the surface. Observations indicate that the magnetic field is filamentary and intermittent across a wide range of spatial scales. However, we do not know to what extent the complex flux-tube topology seen near the Sun survives as the wind expands into interplanetary space. In order to study the possible long-distance connections between the corona and the heliosphere, we developed new models of turbulence-driven solar wind acceleration along empirically constrained field lines. We used a potential field model of the quiet Sun to trace field lines into the ecliptic plane with unprecedented spatial resolution at their footpoints. For each flux tube, a one-dimensional model was created with an existing wave/turbulence code that solves equations of mass, momentum, and energy conservation from the photosphere to 4 AU. To take account of stream-stream interactions between flux tubes, we used those models as inner boundary conditions for a time-steady magnetohydrodynamic description of radial and longitudinal structure in the ecliptic. Corotating stream interactions smear out much of the smallest-scale variability, making it difficult to see how individual flux tubes on granular or supergranular scales can survive out to 1 AU. However, our models help clarify the level of ''background'' variability with which waves and turbulent eddies should be expected to interact. Also, the modeled fluctuations in magnetic field magnitude were seen to match measured power spectra quite well.

79 ASTRONOMY AND ASTROPHYSICS↗

First Measurements and Results With a Stretched Wire Test Setup

The LINAC Coherent Light Source [LCLS] is a free electron laser, designed to produce high brilliant X-ray beams using Self Amplified Spontaneous Emission [SASE]. Due to the physics of SASE, the electron beam has to be held very precisely on the same trajectory as the X-ray light beam generated by the undulator magnets. To optimize the SASE output, trajectory deviations between both beams have to be minimized to a few micrometers along the entire undulator section and held stable over the time period between beam-based-alignment processes. Consequently, extremely high position stability of all magnets in the undulator section is required to operate the LCLS successfully. The knowledge of any magnet movement exceeding few micrometers during periods of several weeks is essential for efficient X-ray generation. A well known principle of monitoring transverse component positions along beam lines is the application of stretched wires, associated with suitable wire position sensors and electronics. The particular challenge at LCLS is the required wire system performance in conjunction with the length of the undulator section and the large number of monitors. Verification of system stability and resolution under real conditions is the primary goal of this test setup. A stretched wire test setup has been implemented to gain experience for the final design of a wire system, which will meet the position monitoring requirements in the LCLS undulator section. The report briefly introduces the system's architecture and describes first measurements and results.

43 PARTICLE ACCELERATORS↗

High-resolution and site-specific scanning spreading resistance microscopy and its applications to silicon devices

Due to the continuous reduction of the critical dimensions of semiconductor devices, it becomes very important to know the two dimensional (2D) doping profile for improving device performance. Scanning spreading resistance microscopy (SSRM) performed in high vacuum is a powerful technique for quantitative 2D-doping profiling, with high spatial resolution and wide dynamic range of carrier concentration, as well as capability of site-specific analysis for accurate position. In this paper, we review SSRM applications to source/drain engineering in Si devices and their correlation with device characteristics by demonstrating several case studies. Direct observation of (110)/(100) CMOSFETs clarified significant differences between both pFETs and nFETs on (110) and (100) silicon substrates, revealing 2D channeling effect of boron ion implantation in pFETs; as well as silicidation impact on junction leakage-current characteristics in nFETs. Furthermore, our sample-preparation breakthrough enables site-specific SSRM characterization within 60 nm ultra thin samples and therefore failure analysis of real SRAM devices, demonstrating the high potential of SSRM technology for further device scaling and for failure analysis.

36 MATERIALS SCIENCE↗

High resolution Fourier interferometer-spectrophotopolarimeter

A high-resolution Fourier interferometer-spectrophotopolarimeter is provided using a single linear polarizer-analyzer the transmission axis azimuth of which is positioned successively in the three orientations of 0 deg, 45 deg, and 90 deg, in front of a detector; four flat mirrors, three of which are switchable to either of two positions to direct an incoming beam from an interferometer to the polarizer-analyzer around a sample cell transmitted through a medium in a cell and reflected by medium in the cell; and four fixed focussing lenses, all located in a sample chamber attached at the exit side of the interferometer. This arrangement can provide the distribution of energy and complete polarization state across the spectrum of the reference light entering from the interferometer; the same light after a fixed-angle reflection from the sample cell containing a medium to be analyzed; and the same light after direct transmission through the same sample cell, with the spectral resolution provided by the interferometer.

Fymat, A. L.↗

TH-CD-201-07: Experimentally Investigating Proton Energy Deposition On the Microscopic Scale Using Fluorescence Nuclear Track Detectors

Purpose: In order to further understand the interplay between proton physics and radiobiology it is necessary to consider proton energy deposition on the microscopic scale. In this work we used Fluorescent Nuclear Track Detectors (FNTDs) to experimentally investigate proton energy deposition, track-by-track. Methods: We irradiated 8×4×0.5mm{sup 3} FNTD chips (Landauer Inc) at seven water depths along a pristine proton Bragg peak with range=12cm. After irradiation, the FNTDs were scanned using a confocal microscope (FV1200, Olympus) with a high-power red laser and an oil-immersion objective lens (UPLSAPO60XO, NA=1.35). 10 slice image stacks were acquired with a slice-thickness of 2µm at multiple positions across each FNTD. Image-based analyses of track radius and track “mass” (integrated signal intensity) were performed using trackpy. For comparison, Monte Carlo simulated data were obtained using TOPAS and TOPAS-nBio. Results: Excellent correlation was observed between median track mass and TOPAS dose-averaged linear energy transfer. The resolution of the imaging system was determined insufficient to detect a relationship between track radius and exposure depth. Histograms of track mass (i) displayed strong repeatability across positions within an FNTD and (ii) varied in peak position and shape as a function of depth. TOPAS-nBio simulations implemented on the nanometer scale using physics lists from GEANT4-DNA yielded energy deposition distributions for individual protons and electrons scored within a virtual FNTD. Good agreement was found between these simulated datasets and the FNTD track mass distributions. Conclusion: Robust experimental measurements of the integral energy deposited by individual proton tracks can be performed using FNTDs. Monte Carlo simulations offer an exceedingly powerful approach to the quantification of proton energy deposition on the microscopic scale, but whilst they have been well validated at the macroscopic level, their microscopic validation is far from complete. Our results demonstrate that FNTD-based study can play an important role in addressing this deficit. Tracy Underwood gratefully acknowledges the support of the European Commission under an FP7 Marie Curie International Outgoing Fellowship for Career Development (#630064).

60 APPLIED LIFE SCIENCES↗

A second‐generation virtual‐pinhole PET device for enhancing contrast recovery and improving lesion detectability of a whole‐body PET/CT scanner

Purpose We have developed a second‐generation virtual‐pinhole (VP) positron emission tomography (PET) device that can position a flat‐panel PET detector around a patient's body using a robotic arm to enhance the contrast recovery coefficient (CRC) and detectability of lesions in any region‐of‐interest using a whole‐body PET/computed tomography (CT) scanner. Methods We constructed a flat‐panel VP‐PET device using 32 high‐resolution detectors, each containing a 4 4 MPPC array and 16 16 LYSO crystals of 1.0 1.0 3.0 mm 3 each. The flat‐panel detectors can be positioned around a patient's body anywhere in the imaging field‐of‐view (FOV) of a Siemens Biograph 40 PET/CT scanner by a robotic arm. New hardware, firmware and software have been developed to support the additional detector signals without compromising a scanner's native functions. We stepped a 22 Na point source across the axial FOV of the scanner to measure the sensitivity profile of the VP‐PET device. We also recorded the coincidence events measured by the scanner detectors and by the VP‐PET detectors when imaging phantoms of different sizes. To assess the improvement in the CRC of small lesions, we imaged an elliptical torso phantom measuring 316 228 162 mm 3 that contains spherical tumors with diameters ranging from 3.3 to 11.4 mm with and without the VP‐PET device. Images were reconstructed using a list mode Maximum‐Likelihood Estimation‐Maximization algorithm implemented on multiple graphics processing units (GPUs) to support the unconventional geometries enabled by a VP‐PET system. The mean and standard deviation of the CRC were calculated for tumors of different sizes. Monte Carlo simulation was also conducted to image clusters of lesions in a torso phantom using a PET/CT scanner alone or the same scanner equipped with VP‐PET devices. Receiver operating characteristic (ROC) curves were analyzed for three system configurations to evaluate the improvement in lesion detectability by the VP‐PET device over the native PET/CT scanner. Results The repeatability in positioning the flat‐panel detectors using a robotic arm is better than 0.15 mm in all three directions. Experimental results show that the average CRC of 3.3, 4.3, and 6.0 mm diameter tumors was 0.82%, 2.90%, and 5.25%, respectively, when measured by the native scanner. The corresponding CRC was 2.73%, 6.21% and 10.13% when imaged by the VP‐PET insert device with the flat‐panel detector under the torso phantom. These values may be further improved to 4.31%, 9.65% and 18.01% by a future dual‐panel VP‐PET insert device if DOI detectors are employed to triple its detector efficiency. Monte Carlo simulation results show that the tumor detectability can be improved by a VP‐PET device that has a single flat‐panel detector. The improvement is greater if the VP‐PET device employs a dual‐panel design. Conclusions We have developed a prototype flat‐panel VP‐PET device and integrated it with a clinical PET/CT scanner. It significantly enhances the contrast of lesions, especially for those that are borderline detectable by the native scanner, within regions‐of‐interest specified by users. Simulation demonstrated the enhancement in lesion detectability with the VP‐PET device. This technology may become a cost‐effective solution for organ‐specific imaging tasks.

Jiang, Jianyong↗

Probing Light Atoms at Subnanometer Resolution: Realization of Scanning Transmission Electron Microscope Holography

Atomic resolution imaging of light elements in electron-transparent materials has long been a challenge. Biomolecular materials, for example, are rapidly altered by incident electrons. We demonstrate a scanning transmission electron microscopy (STEM) technique, called STEM holography, capable of efficient structural analysis of beam-sensitive nanomaterials. STEM holography measures the absolute phase and amplitude of electrons passed through a specimen via interference with a vacuum reference wave. We use an amplitude-dividing nanofabricated grating to prepare multiple beams focused at the sample. We configure the postspecimen microscope imaging system to overlap the beams, forming an interference pattern. We record and analyze the pattern at each 2D-raster-scan-position, reconstructing the complex object wave. As a demonstration, we image gold nanoparticles on an amorphous carbon substrate at 2.4 Å resolution. In conclusion STEM holography offers higher contrast of the carbon while maintaining gold atomic lattice resolution compared to high angle annular dark field STEM.

4D-STEM↗

CONSTRAINING THE TRUE NATURE OF AN EXOTIC BINARY IN THE CORE OF NGC 6624

We report on the identification of the optical counterpart to Star1, the exotic object serendipitously discovered by Deutsch et al. in the core of the Galactic globular cluster NGC 6624. Star1 has been classified by Deutsch et al. as either a quiescent cataclysmic variable or a low-mass X-ray binary. Deutsch et al. proposed StarA as a possible optical counterpart to this object. We used high-resolution images obtained with the Hubble Space Telescope to perform a variability analysis of the stars close to the nominal position of Star1. While no variability was detected for StarA, we found another star, referred to here as COM{sub S}tar1, showing a clear sinusoidal light modulation with amplitude Δm {sub F435W} ∼ 0.7 mag and an orbital period of P {sub orb} ∼ 98 minutes. The shape of the light curve is likely caused by strong irradiation by the primary heating of one hemisphere of the companion, thus suggesting a quite hot primary.

79 ASTRONOMY AND ASTROPHYSICS↗

SeaWiFS technical report series. Volume 15: The simulated SesWiFS data set, version 2

This document describes the second version of the simulated SeaWiFS data set. A realistic simulated data set is essential for mission readiness preparations and can potentially assist in all phases of ground support for a future mission. The second version improves on the first version primarily through additional realism and complexity. This version incorporates a representation of virtually every aspect of the flight mission. Thus, it provides a high-fidelity data set for testing several aspects of the ground system, including data acquisition, data processing, data transfers, calibration and validation, quality control, and mission operations. The data set is constructed for a seven-day period, 25-31 March 1994. Specific features of the data set include Global Area coverage (GAC), recorded Local Area Coverage (LAC), and realtime High Resolution Picture Transmission (HRPT) data for the seven-day period. A realistic orbit, which is propagated using a Brouwer-Lyddane model with drag, is used to simulate orbit positions. The simulated data corresponds to the command schedule based on the orbit for this seven-day period. It includes total (at-satellite) radiances not only for ocean, but for land, clouds, and ice. The simulation also utilizes a high-resolution land-sea mask. It includes the April 1993 SeaWiFS spectral responses and sensor saturation responses. The simulation is formatted according to July 1993 onboard data structures, which include corresponding telemetry (instrument and spacecraft) data. The methods are described and some examples of the output are given. The instrument response functions made available in April 1993 have been used to produce the Version 2 simulated data. These response functions will change as part of the sensor improvements initiated in July-August 1993.

Hooker, Stanford B.↗

Resolving the Inner Parsec of the Blazar J1924–2914 with the Event Horizon Telescope

The blazar J1924–2914 is a primary Event Horizon Telescope (EHT) calibrator for the Galactic center’s black hole Sagittarius A*. Here we present the first total and linearly polarized intensity images of this source obtained with the unprecedented 20 μas resolution of the EHT. J1924–2914 is a very compact flat-spectrum radio source with strong optical variability and polarization. In April 2017 the source was observed quasi-simultaneously with the EHT (April 5–11), the Global Millimeter VLBI Array (April 3), and the Very Long Baseline Array (April 28), giving a novel view of the source at four observing frequencies, 230, 86, 8.7, and 2.3 GHz. These observations probe jet properties from the subparsec to 100 pc scales. We combine the multifrequency images of J1924–2914 to study the source morphology. We find that the jet exhibits a characteristic bending, with a gradual clockwise rotation of the jet projected position angle of about 90° between 2.3 and 230 GHz. Linearly polarized intensity images of J1924–2914 with the extremely fine resolution of the EHT provide evidence for ordered toroidal magnetic fields in the blazar compact core.

79 ASTRONOMY AND ASTROPHYSICS↗

Direct comparison between X-ray nanotomography and scanning electron microscopy for the microstructure characterization of a solid oxide fuel cell anode

X-ray computed nanotomography (nano-CT) and scanning electron microscopy (SEM) have been applied to characterize the microstructure of a Solid Oxide Fuel Cell (SOFC) anode. A direct comparison between the results of both methods is conducted on the same region of the microstructure to assess the spatial resolution of the nano-CT microstructure, SEM being taken as a reference. A registration procedure is proposed to find out the position of the SEM image within the nano-CT volume. It involves a second SEM observation, which is taken along an orthogonal direction and gives an estimate reference SEM image position, which is then refined by an automated optimization procedure. This enables an unbiased comparison between the cell porosity morphologies provided by both methods. In the present experiment, nano-CT is shown to underestimate the number of pores smaller than 1 μm and overestimate the size of the pores larger than 1.5 μm. - Highlights: ► X-ray computed nanotomography (nano-CT) and SEM are used to characterize an SOFC anode. ► A methodology is proposed to compare the nano-CT and SEM data on the same region. ► The spatial resolution of the nano-CT data is assessed from that comparison.

36 MATERIALS SCIENCE↗

High-count-rate effects in event processing for the XRISM/Resolve X-ray microcalorimeter. II. Energy scale and resolution in orbit

The Resolve instrument on the X-ray Imaging and Spectroscopy Mission (XRISM) uses a 36 pixel microcalorimeter designed to deliver high-resolution, non-dispersive X-ray spectroscopy. Although it is optimized for extended sources with low count rates, Resolve observations of bright point sources are still able to provide unique insights into the physics of these objects, as long as high-count-rate effects are addressed in the analysis. These effects include the loss of exposure time for each pixel, changes in the energy scale, and changes in the energy resolution. To investigate these effects under realistic observational conditions, we observed the bright X-ray source, the Crab Nebula, with XRISM at several offset positions with respect to the Resolve field of view and with continuous illumination from 55 Fe sources on the filter wheel. For the spectral analysis, we excluded data where exposure-time loss was too significant to ensure reliable spectral statistics. The energy scale at 6 keV shows a slight negative shift in the high-count-rate regime. The energy resolution at 6 keV worsens as the count rate in electrically neighboring pixels increases, but can be restored by applying a nearest-neighbor coincidence cut (“cross-talk cut”). We examined how these effects influence the observation of bright point sources, using GX 13+1 as a test case, and identified an eV-scale energy offset at 6 keV between the inner (brighter) and outer (fainter) pixels. Users who seek to analyze velocity structures on the order of tens of km s–1 should account for such high-count-rate effects. These findings will aid in the interpretation of Resolve data from bright sources and provide valuable considerations for designing and planning for future microcalorimeter missions.