Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Definition of Capabilities Needed for a Single Event Effects Test Facility

The Federal Aviation Administration (FAA) is contemplating new regulations mandating testing of the vulnerability of flight-critical avionics to single event effects (SEE). A limited number of high-energy neutron test facilities currently serve the SEE industrial and institutional research community. The FAA recognizes that existing facilities have insufficient test capacity to meet new demand from such mandates; it desires more flexible irradiation capabilities to test complete, large systems and would like capabilities to address greater concerns for thermal neutrons. For this reason, the FAA funded this study by Spallation Neutron Source (SNS) staff with the ultimate aim of developing options for SEE test facilities using high-energy neutrons at the SNS complex. After an investigation of current SEE test practices and assessment of future testing requirements, three concepts were identified covering a range of test functionality, neutron flux levels, and fidelity to the atmospheric neutron spectrum. The costs and times required to complete each facility were also estimated. SEE testing is generally performed by accelerating the event rate to a point where the effects are still dominated by single events and double event causes of failures are negligible. In practice, acceleration factors of as high as 10 6 are applicable for component testing, whereas for systems testing acceleration factors of 10 4 seem to be the upper limit. It is strongly desirable that the irradiation facility be tunable over a large range of high-energy neutron fluxes of 10 2 - 10 4 n/cm²/s for systems testing and from 10 4 - 10 7 n/cm²/s for components testing. The most capable, most flexible, and highest-test-capacity option is a new stand-alone target station named the High-Energy neutron Test Station (HETS). It is also the most expensive option, with a cost to complete of approximately $100 million. Dual test enclosures would allow for simultaneous testing activity effectively doubling overall test capacity per HETS operating hour. Using about 1 kilowatt (kW) of proton power extracted from the accelerator before injection in the accumulator ring, its operation would be unnoticeable by neutron scattering users at the SNS target station. The H beam laser stripping technique would allow for control of beam power on the HETS target independent from power delivered to the SNS. Large systems with frontal areas of up to 1 x 2 m² could be accommodated with integral high-energy flux values (above 10 megaelectron-volt, or MeV) to at most 10 4 n/cm²/s; components could also be tested with flux levels to at most 10 7 n/cm²/s on beam sizes of up to 0.2 x 0.2 m². Selectable moderating material and neutron filters would allow tailoring of the neutron spectrum to user demands; charged particle deflectors could be switched to allow or deflect protons, pions, and muons. It is estimated that HETS would take 5 years to complete after award of contract, including engineering design and construction. Commissioning would take at least another 6 months. Interference with SNS principal operations was not considered in the construction time estimate; connection of the proton transport line and tunnel from the accelerator high energy beam transport (HEBT) and construction around existing site utilities would require careful planning and coordination with beam operations at the SNS. A high-energy (HE) neutron test facility using an available beam line on the SNS target station is a technically and financially attractive option. Inspired by the new ChipIR instrument on the ISIS TS 2 spallation source in the UK, a similar facility could be placed on an unused beam line in the SNS instrument hall [e.g., on beam line 8 (both A and B channels would be needed) or on beam line 10]. The performance would approach that of an HETS (~80%), but it would be operationally more limited, with only a single user at a time. Space is more limited, so the maximum system size would be about half of that in an HETS. Flexibility to tailor the spectrum would be somewhat more limited. While this concept was not as fully developed and characterized, preliminary work indicates very high HE flux levels should be possible, with ample thermal neutrons as well. Flux control would be more difficult than at HETS because proton power on target be whatever the SNS was operating at for neutron scattering. Neutron attenuation devices would have to be employed with as-yet undetermined control resolution. However, no new buildings would be needed, and the necessary utilities are already present in the SNS Experiment Hall. The estimated cost for a beam line option is around $15 million; the time to complete would be 3 years after award of contract, plus at least 6 months for commissioning. Interference of construction activities with SNS operations should be negligible. This option would require negotiation with the Department of Energy Basic Energy Sciences (BES) office -- the primary stakeholder of SNS -- for an application outside the usual scope of neutron scattering sciences. Furthermore, these presently open beam lines are highly desirable locations for proposed neutron scattering instruments and obtaining one of them for an SEE test facility will come only with persuasive and timely arguments to SNS leadership and the DOE BES. The third option is a tunnel extension/target cave facility providing the most basic system-level irradiation capability with minimal flexibility. Again not as well developed a concept as HETS, it would use a laser-stripping technique like an HETS, redirecting protons to a tunnel similar to the initial HETS proton transport tunnel. Indeed, this concept is intended to be upgradable to a full HETS facility. Only a small fraction of a watt of proton power would be used in this basic configuration, though. An uncooled target and primitive shielding arrangement would provide beam on modestly sized systems that must be placed in close proximity to the target. The neutron fluence would be less uniform over the system than with the HETS or the beam line option. A data acquisition room and support area would be located on the ground level; access to the target cave would be via elevator and/or stairway. As a result of the required excavation, new tunnel construction, shielding, data acquisition building, utilities, and other items, the estimated cost is $30 million. The time to complete is expected be more than 3 years; here again construction interference with SNS operations has not been accounted for, but it could have a significant impact.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Control of sawtooth via ECRH on EAST tokamak

Localized electron heating produced by electron cyclotron resonant heating (ECRH) system has been proven to be powerful tools for controlling sawtooth instabilities, because such system allows to directly modify the local plasma parameters that determine the evolution of sawtooth periods. In this paper, we present the experimental results carried out on experimental advanced superconducting tokamak (EAST) with regard to sawtooth period control via ECRH. The electron cyclotron heating system on EAST was capable of inject electron cyclotron wave toward certain locations inside or outside q = 1 magnetic surface on the poloidal cross section, which renders us able to investigate the evolution of sawtooth period against the ECRH deposition position. It is found that when ECRH deposition position is inside the q = 1 surface, the sawtooth oscillation is destabilized (characterized by reduced sawtooth period). So far, inside the q = 1 surface, there are not enough EAST experiment data that can reveal more detailed information about the relation between ECRH deposition position and sawtooth period. When ECRH deposition is outside the q = 1 surface, the sawtooth oscillation is stabilized (characterized by prolonged sawtooth period), and the sawtooth periods gradually decrease as ECRH deposition position sweeps away from q = 1 surface. The sawtooth periods reach maximum when ECRH deposition position falls around q = 1 surface. The magnetic shear at q = 1 surface is calculated to offer insights for the temporal evolution of sawtooth. The result has been found consistent with the Porcelli model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling and Compensation Design for a Power Hardware-in-the-Loop Simulation of an AC Distribution System

Power hardware-in-the-loop (PHIL) simulation, where actual hardware under text is coupled with a real-time digital model in closed loop, is a powerful tool for analyzing new methods of control for emerging distributed power systems. However, without careful design and compensation of the interface between the simulated and actual systems, PHIL simulations may exhibit instability and modeling inaccuracies. This paper addresses issues that arise in the PHIL simulation of a hardware battery inverter interfaced with a simulated distribution feeder. Both the stability and accuracy issues are modeled and characterized, and a methodology for design of PHIL interface compensation to ensure stability and accuracy is presented. The stability and accuracy of the resulting compensated PHIL simulation is then shown by experiment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of Model Simplification on Optimal Control of Combustion Engine and Electric Vehicles Considering Control Input Constraints

This paper analyzes the impact of model simplification on optimal control for electric and conventional engine-powered vehicles. An optimal control problem is formulated to minimize energy/fuel consumption subject to control input constraints and solved analytically using the Pontryagin's Minimum Principle. We found that simplified solutions without nonlinear aerodynamic drag are sub-optimal, and their loss of optimality increases with average travel speed. The energy/fuel savings of each control approach are evaluated using the intelligent driver model to capture driving behavior of a driver. Simulation case studies are presented for illustration.

Han, Jihun↗

TidGen LCOE Workbooks

Workbooks showing Annualized Energy Production, Cost Breakdown Structure, Levelized Cost of Electricity for DOE Refernce Tidal Project 1) Baseline TidGen Power System 2) TidGen Power System with the application of Advanced Controls 3) Advanced TidGen Power System with several enhancements These files are provided as a zipped set. Files are linked together and must be viewed in the same folder.

16 TIDAL AND WAVE POWER↗

Measurement of the QE Map

113 MHz SRF gun utilized CsK 2 Sb and Na 2 KSb cathodes, which were irradiated with a pulsed green laser with a wavelength of 0.53 microns. The drive laser generated 78 kHz pulses with an acousto-optic modulator selecting the desired number of pulses reaching the cathode. The operator can select the aperture size, defining the laser spot diameter on the cathode, and the power level, which is controlled by a rotating polarizer. The laser power reaching the cathode can be measured with a meter based on a photodiode. The quantum efficiency (QE) of a photocathode serves as a primary indicator of its state. Small QE renders the cathode unusable when the desired bunch charge cannot be achieved. Strong variations in the quantum efficiency on the cathode surface might lead to the growth of the beam emittance due to the space charge effects. We have created a routine to measure the distribution of the QE on the cathode. The operator selects the aperture size, the central spot location, and the scan ranges for both planes. The scan starts from the central spots and proceeds along a spiral-like trajectory, making N rounds. The number of rounds can be chosen, and the total number of measured points is (2N+1) 2 . The laser spot movement is shown in Fig. 1.

43 PARTICLE ACCELERATORS↗

Modeling and Compensation Design for a Power Hardware-in-the-Loop Simulation of an AC Distribution System: Preprint

Power hardware-in-the-loop (PHIL) simulation, where actual hardware under text is coupled with a real-time digital model in closed loop, is a powerful tool for analyzing new methods of control for emerging distributed power systems. However, without careful design and compensation of the interface between the simulated and actual systems, PHIL simulations may exhibit instability and modeling inaccuracies. This paper addresses issues that arise in the PHIL simulation of a hardware battery inverter interfaced with a simulated distribution feeder. Both the stability and accuracy issues are modeled and characterized, and a methodology for design of PHIL interface compensation to ensure stability and accuracy is presented. The stability and accuracy of the resulting compensated PHIL simulation is then shown by experiment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ELECTRICAL BREAKDOWN STRENGTH AND AC WITHSTAND IN HARVESTED EPR INSULATIONS FOR NUCLEAR POWER PLANTS

While the operating voltages for some instrument and control (I&C) cables can be greater than 4 kV to operate pumps, controls, and provide auxiliary power, the operating voltage for most I&C cables is near 600 V. Although the electrical stress is not nearly as high in the insulation of these cables, an ac withstand two and one-half times greater than the operating voltage after a simulated design basis exposure (DBE) has been used in environmental qualification (EQ) to determine the ability of an insulation to meet a 40-year lifetime at an operating voltage. While multiple cable lengths greater than 10 feet are needed to replicate this EQ, systematic measurement of the electrical insulation strength in harvested cable insulations can be beneficial to better understand the remaining useful life of the insulation. This understanding can only be realized through systematic comparison to some level of DBE, and electrical insulation strength measurement can provide a baseline for comparison with other mechanical, chemical, and electrical characterizations that have been utilized. Accelerated aging of two types of ethylene propylene rubber (EPR) insulations from harvested cables was carried out, and the electrical breakdown strength and indenter modulus for both insulations were determined. Results showed that degradation of electrical breakdown strength occurred in only one type of BIW insulation and that this degradation did track with that measured by indenter modulus. The methodology for using Weibull statistics for electrical breakdown strength relative to time to failure is discussed.

Duckworth, Robert↗

Synchronous micromechanically resonant programmable photonic circuits

Abstract Programmable photonic integrated circuits (PICs) are emerging as powerful tools for control of light, with applications in quantum information processing, optical range finding, and artificial intelligence. Low-power implementations of these PICs involve micromechanical structures driven capacitively or piezoelectrically but are often limited in modulation bandwidth by mechanical resonances and high operating voltages. Here we introduce a synchronous, micromechanically resonant design architecture for programmable PICs and a proof-of-principle 1×8 photonic switch using piezoelectric optical phase shifters. Our design purposefully exploits high-frequency mechanical resonances and optically broadband components for larger modulation responses on the order of the mechanical quality factor Q m while maintaining fast switching speeds. We experimentally show switching cycles of all 8 channels spaced by approximately 11 ns and operating at 4.6 dB average modulation enhancement. Future advances in micromechanical devices with high Q m , which can exceed 10000, should enable an improved series of low-voltage and high-speed programmable PICs.

42 ENGINEERING↗

Co-Simulation of Detailed Whole Building with the Power System to Study Smart Grid Applications

Modernization of the power system in a way that ensures a sustainable energy system is arguably one of the most pressing concerns of our time. Buildings are important components in the power system. First, they are the main consumers of electricity and secondly, they do not have constant energy demand. Conventionally, electricity has been difficult to store and should be consumed as it is generated. Therefore, maintaining the demand and supply is critical in the power system. However, to reduce the complexity of power models, buildings (i.e., end-use loads) are traditionally modeled and represented as aggregated “dumb” nodes in the power system. This means we lack effective detailed whole building energy models that can support requirements and emerging technologies of the smart power grid. To gain greater insight into the relationship between building energy demand and power system performance, it is important to constitute a co-simulation framework to support detailed building energy modeling and simulation within the power system to study capabilities promised by the modern power grid. This paper discusses ongoing work at Pacific Northwest National Laboratory and presents underlying tools and framework needed to enable co-simulation of building, building energy systems and their control in the power system to study applications such as demand response, grid-based HVAC control, and deployment of buildings for ancillary services. The optimal goal is to develop an integrated modeling and simulation platform that is flexible, reusable, and scalable. Results of this work will contribute to future building and power system studies, especially those related to the integrated ‘smart grid’. Results are also expected to advance power resiliency and local (micro) scale grid studies where several building and renewable energy systems transact energy directly. This paper also reviews some applications that can be supported and studied using the framework introduced to understand their implications before they can be successfully implemented in the power system.

Makhmalbaf, Atefe↗

Balancing Power Absorption and Structural Loading for a Novel Fixed-Bottom Wave Energy Converter with Nonideal Power Take-Off in Regular Waves: Preprint

In this work, the net power delivered to the grid from a nonideal power take-off (PTO) is introduced followed by a review of the pseudo-spectral control theory. A power-to-load ratio, used to evaluate the pseudo-spectral controller performance, is discussed, and the results obtained from optimizing a multiterm objective function are compared against results obtained from maximizing the net output power to the grid. Simulation results are then presented for four different oscillating wave energy converter geometries to highlight the potential of combing both geometry and PTO control to maximize power while minimizing loads.

16 TIDAL AND WAVE POWER↗

Systems usability case in stepwise control room validation - 125

We present a Systems Usability Case (SUC) approach enabling a requirement-based human factors evaluation of complex technical systems. The approach is especially suitable for stepwise verification and validation (V and V) of nuclear power plant (NPP) control room (CR) systems. A SUC is based on the Safety Case approach and on the Systems Usability (SU) construct. A series of V and V test activities carried throughout the design process and constructed according to SUC enables us to monitor how evaluation evidence is aggregated over variety of V and V steps and how the design solution is maturing towards a tool of a good quality and usability. The paper demonstrates an application of the SUC approach to real data from a stepwise CR validation. The results suggest that SUC has some clear advantages. It makes it easier to conduct the V and V activities in a more systematic fashion and it makes the reasoning process more explicit and transparent. Moreover, it enables building a longitudinal view of the progress of the design process. Most importantly, constructing the SUC enables monitoring of the fulfilment of the requirements from the human factors (i.e., SU) perspective. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Critical values of cyber parameters in a dynamic microgrid system

An islanded microgrid can be used to serve critcal load as a resiliency source when a severe outage occurs. In an islanded mode, control of a microgrid relies on the communication system significantly. Hence, microgrids are cyberphysical systems and, therefore, the cyber system plays a crucial role in the performance of the cyber-power system. A microgrid control scheme is proposed for power dispatch and regulation based on the droop and proportional-integral (PI) feedback control. The proposed control strategy is validated for transient stability following dynamic events. To evaluate the impact of a networked control system on control performance, a cyber model is developed to represent data acquisition periods and communication delays. An analytical method is proposed to determine the critical values for the data reporting periods and communication delays. The analytical method based on a state space model of a networked control system is applicable for large-scale systems. A 2-dimensional stability region of a microgrid in the space of cyber parameters can be obtained by the proposed method, and the critical values of cyber parameters are determined based on the stability region. Simulation results validate that the design of a microgrid as a cyber-physical system needs to be guided by critical values for the data reporting period and communication delay to prevent system instability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid Forming Fast Frequency Response for PMSG-Based Wind Turbines

Electric power systems are undergoing a rapid transition from fuel-based generation using synchronous generators to renewable generation interfaced by power electronics. In this context, a key challenge is using renewable generation with limited controllability to contribute to power system stability. In this work, we investigate grid-forming control of permanent magnet synchronous generator (PMSG) wind turbines. The proposed control and curtailment strategy supports the entire spectrum of standard functions of grid-following (e.g. maximum power point tracking (MPPT) and grid-forming control (e.g., primary frequency control) without explicit mode switching. A detailed case study is used to compare the performance of the proposed control at operating points corresponding to MPPT and frequency control with standard grid-forming and grid-following controls. Further, the results demonstrate that (i) the proposed energy balancing grid forming control is self-synchronizing in MPPT mode, (ii) the (limited) energy storage and controllability of wind turbines can be adequately utilized to provide grid support, and (ii) the proposed control exhibits good performance under variable wind speeds and does not result in a significant increase of wind turbine fatigue loads.

17 WIND ENERGY↗

Development of a diversity and defense-in-depth strategy for the CNNC Fuqing, Fangjiashan and Hainan nuclear plants - 379

The purpose of this paper is to provide an overview of the development of the Diversity and Defense-in- Depth (D3) strategy for the China National Nuclear Corporation Fuqing, Fangjiashan, and Hainan Nuclear Plants. The Nuclear Power Plant (NPP) Digital Control System (DCS) and advanced control room was completed by Invensys and China Nuclear Power Engineering (CNPE)/Nuclear Power Institute of China (NPIC) for these eight new Chinese built Pressurized Water Reactor plants. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A State-Space Model of an Inverter-Based Microgrid for Multivariable Feedback Control Analysis and Design

In this work, a synchronous model for grid-connected and islanded microgrids is presented. The grid-connected model is based on the premise that the reference frame is synchronized with the AC bus. The quadrature component of the AC bus voltage can be cancelled, which allows to express output power as a linear equation for nominal values in the AC bus amplitude voltage. The model for the islanded microgrid is developed by integrating all the inverter dynamics using a state-space model for the load currents. This model is presented in a comprehensive way such that it could be scalable to any number of inverter-based generators using inductor–capacitor–inductor (LCL) output filters. The use of these models allows designers to assess microgrid stability and robustness using modern control methods such as eigenvalue analysis and singular value diagrams. Both models were tested and validated in an experimental setup to demonstrate their accuracy in describing microgrid dynamics. In addition, three scenarios are presented: non-controlled model, Linear-Quadratic Integrator (LQI) power control, and Power-Voltage (PQ/Vdq) droop–boost controller. Experimental results demonstrate the effectiveness of the control strategies and the accuracy of the models to describe microgrid dynamics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Vehicle electrical system state controller

A motor vehicle electrical power distribution system includes a plurality of distribution sub-systems, an electrical power storage sub-system and a plurality of switching devices for selective connection of elements of and loads on the power distribution system to the electrical power storage sub-system. A state transition initiator provides inputs to control system operation of switching devices to change the states of the power distribution system. The state transition initiator has a plurality of positions selection of which can initiate a state transition. The state transition initiator can emulate a four position rotary ignition switch. Fail safe power cutoff switches provide high voltage switching device protection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Way Beyond Widgets: Delivering Integrated Lighting Design in Actionable Solutions

Previously, energy-efficiency strategies for commercial spaces have focused on using efficient equipment without providing specific detailed instructions. Designs by experts in their fields are an energy-efficiency product in its own right. A new national program has developed interactive application-specific lighting designs for widespread use in four major commercial sectors. This paper will describe the technical basis for the solutions, energy efficiency and cost-savings methodology, and installations and measurement/verification to-date. Lighting designs have been developed for five types of retail stores (big box, small box, grocery, specialty market, and pharmacy) and are planned for the office, healthcare, and education sectors as well. Nationally known sustainable lighting designers developed the designs using high-performance commercially available products, daylighting, and lighting controls. Input and peer review was received by stakeholders, including manufacturers, architects, utilities, energy-efficiency program sponsors (EEPS), and end-users (i.e., retailers). An interactive web tool delivers the lighting solutions and analyzes anticipated energy savings using project-specific inputs. The lighting solutions were analyzed against a reference building using the space-by-space method as allowed in the Energy Standard for Buildings Except Low-Rise Residential Buildings (ASHRAE 2004) co-sponsored by the American Society of Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE) and the Illuminating Engineering Society of North America (IESNA). The results showed that the design vignettes ranged from a 9% to 28% reduction in the allowed lighting power density. Detailed control strategies are offered to further reduce the actual kilowatt-hour power consumption. When used together, the lighting design vignettes and control strategies show a modeled decrease in energy consumption (kWh) by 33% to 50% below the baseline design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗