Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Measured dose rate constant from oncology patients administered 18F for positron emission tomography

Purpose: Patient exposure rate measurements verify published patient dose rate data and characterize dose rates near 2-18-fluorodeoxyglucose ({sup 18}F-FDG) patients. A specific dose rate constant based on patient exposure rate measurements is a convenient quantity that can be applied to the desired distance, injection activity, and time postinjection to obtain an accurate calculation of cumulative external radiation dose. This study reports exposure rates measured at various locations near positron emission tomography (PET) {sup 18}F-FDG patients prior to PET scanning. These measurements are normalized for the amount of administered activity, measurement distance, and time postinjection and are compared with other published data. Methods: Exposure rates were measured using a calibrated ionization chamber at various body locations from 152 adult oncology patients postvoid after a mean uptake time of 76 min following injection with a mean activity of 490 MBq {sup 18}F-FDG. Data were obtained at nine measurement locations for each patient: three near the head, four near the chest, and two near the feet. Results: On contact with, 30 cm superior to and 30 cm lateral to the head, the mean (75th percentile) dose rates per unit injected activity at 60 min postinjection were 0.482 (0.511), 0.135 (0.155), and 0.193 (0.223) {mu}Sv/MBq h, respectively. On contact with, 30 cm anterior to, 30 cm lateral to and 1 m anterior to the chest, the mean (75th percentile) dose rates per unit injected activity at 60 min postinjection were 0.623 (0.709), 0.254 (0.283), 0.190 (0.218), and 0.067 (0.081) {mu}Sv/MBq h respectively. 30 cm inferior and 30 cm lateral to the feet, the mean (75th percentile) dose rates per unit injected activity at 60 min postinjection were 0.024 (0.022) and 0.039 (0.044) {mu}Sv/MBq h, respectively. Conclusions: The measurements for this study support the use of 0.092 {mu}Sv m{sup 2}/MBq h as a reasonable representation of the dose rate anterior from the chest of patients immediately following injection. This value can then be reliably scaled to the desired time and distance for planning and staff dose evaluation purposes. At distances closer than 1 m, a distance-specific dose rate constant of 0.367 {mu}Sv/MBq h at 30 cm is recommended for accurate calculations. An accurate patient-specific dose rate constant that accounts for patient-specific variables (e.g., distribution and attenuation) will allow an accurate evaluation of the dose rate from a patient injected with an isotope rather than simply utilizing a physical constant.

07 ISOTOPE AND RADIATION SOURCES↗

Determinants of Toxicity, Patterns of Failure, and Outcome Among Adult Patients With Soft Tissue Sarcomas of the Extremity and Superficial Trunk Treated With Greater Than Conventional Doses of Perioperative High-Dose-Rate Brachytherapy and External Beam Radiotherapy

Purpose: The present study was undertaken to determine factors predictive of toxicity, patterns of failure, and survival in 60 adult patients with soft tissue sarcomas of the extremity and superficial trunk treated with combined perioperative high-dose-rate brachytherapy and external beam radiotherapy. Methods and Materials: The patients were treated with surgical resection and perioperative high-dose-rate brachytherapy (16 or 24 Gy) for negative and close/microscopically positive resection margins, respectively. External beam radiotherapy (45 Gy) was added postoperatively to reach a 2-Gy equivalent dose of 62.9 and 72.3 Gy, respectively. Adjuvant chemotherapy with ifosfamide and doxorubicin was given to patients with advanced high-grade tumors. Results: Grade 3 toxic events were observed in 18 patients (30%) and Grade 4 events in 6 patients (10%). No Grade 5 events were observed. A location in the lower limb was significant for Grade 3 or greater toxic events on multivariate analysis (p = .013), and the tissue volume encompassed by the 150% isodose line showed a trend toward statistical significance (p = .086). The local control, locoregional control, and distant control rate at 9 years was 77.4%, 69.5%, and 63.8%, respectively. On multivariate analysis, microscopically involved margins correlated with local control (p = .036) and locoregional control (p = .007) and tumor size correlated with distant metastases (p = .004). The 9-year disease-free survival and overall survival rate was 47.0% and 61.5%, respectively. Multivariate analysis showed poorer disease-free survival rates for patients with tumors >6 cm (p = .005) and microscopically involved margins (p = .043), and overall survival rates decreased with increasing tumor size (p = .011). Conclusions: Grade 3 or greater wound complications can probably be decreased using meticulous treatment planning to decrease the tissue volume encompassed by the 150% isodose line, especially in lower limb locations. Microscopically involved margins remain a predictor of local and locoregional failure, despite radiation doses >70 Gy. Patients with tumors {>=}6 cm and microscopically involved margins are at high risk of treatment failure and death from the development of distant metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Total dose performance of radiation hardened voltage regulators and references

Total dose test of commercially available radiation hardened bipolar voltage regulators and references show reduced sensitivity to dose rate and varying sensitivity to bias under pressure. Behavior of critical parameters in different dose rate and bias conditions is compared and the impact to hardness assurance methodology is discussed.

radiation total dose low dose rate bias effects re↗

Low-dose-rate Brachytherapy for Prostate Cancer in Low-resource Settings

Purpose: In areas with limited health care, it is important to identify and implement effective treatment methods and to optimize available resources. We investigated the implementation of a low-dose-rate (LDR) brachytherapy program for the treatment of prostate cancer (PCa) in a low-resource setting such as Puerto Rico (PR), where PCa is the main cause of cancer-associated death. Methods and Materials: After institutional approval, the medical records of patients with nonmetastatic PCa undergoing LDR brachytherapy from 2008 to 2013 were reviewed from PR. The factors analyzed included adequate D{sub 90} (radiation dose delivered to 90% of the target volume) coverage (≥140 Gy), early and late toxicity (Common Terminology Criteria for Adverse Events grade >2), and prostate-specific antigen failure. Freedom from biochemical failure was evaluated using Kaplan-Meier analysis. Results: The barriers to implementation of LDR brachytherapy in a country with limited resources were identified. These included lack of access to funding for startup costs, specific referral patterns, lack of trained support staff, such as dosimetrists and physicists, and initial opposition from insurance companies for reimbursement. The initial results from 191 patients were included in the present study with a median follow-up period of 26 months. Prostate-specific antigen failure occurred in 6 patients (3%). No early or late gastrointestinal toxicity (grade >2) developed. Only 3 (2%) and 2 (1%) patients experienced early and late genitourinary toxicity (grade >2), respectively. The 2- and 3-year freedom from biochemical failure in this population was 97% and 95.9%, respectively. Conclusions: At present, limited data are available delineating the barriers faced by low-resource settings in the implementation of LDR brachytherapy. Our data highlight the issues unique to this environment and support the use of LDR brachytherapy as a reliable and effective treatment modality for patients with PCa in low-resource settings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a Physical-Topological Model for the Response of a High-Power Vertical DMOS Transistor to the Effect of Pulsed Gamma-Radiation

A method for developing models of semiconductor devices with two-dimensional nonuniform concentration profiles of donors and acceptors in working regions of a semiconductor device structure is for the first time proposed based on a complex of physical-topological modeling of charge carrier transport and process simulation of the forming processes of the device structure. The application of process simulation is due to the need to correctly define the parameters of the semiconductor device structure, which are used as initial data to calculate the electron transport according to the physical-topological model. The parameters of production processes of ion implantation, diffusion, and lithography, which were refined during process simulation, are determined for a high-power metal—oxide—semiconductor (MOS) transistor forming by the double diffusion method in accordance with known electrical characteristics and measured geometrical sizes of the structure. This results in two-dimensional distribution profiles of donors and acceptors in p–n junctions necessary to calculate the transistor breakdown under the effect of pulsed γ radiation. Breakdown processes are modeled with the help of the physical-topological model based on the Poisson and continuity equations as well as expressions for the diffusion and drift current densities in the transistor. Accounting for carriers formed at the instant of γ irradiation is implemented by the introduction of the dependence of the generation coefficient of electron–hole pairs on the radiation-dose power. The results of calculations correlate well with the experimental data, which makes it possible to give a conclusion regarding the adequacy of the proposed complex model.

36 MATERIALS SCIENCE↗

Risks of Transportation Along Various Routes to the Nevada Test Site

Residents of Southern Nevada have expressed interest in the risks posed by transportation of radioactive materials to the Nevada Test Site for disposal. Residents of the urban sections of Clark County, in particular, are concerned because the trucks carrying this material pass through fairly densely populated areas on both primary and secondary highways. Excellent studies by the Desert Research Institute (Miller, et al, 2005; 2007) measured the external radiation doses from these trucks and provided a benchmark for estimating the doses sustained by the population along the transportation routes. The studies did not, however, assess the doses to the population in the event of an accident involving these trucks. The present study estimates doses to the population along these routes and to various individual receptors, both for routine, incident-free transportation and for transportation accidents.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

What a difference a delay makes! CT urogram: a pictorial essay

Purpose: The aim of this pictorial essay is to demonstrate several cases where the diagnosis would have been difficult or impossible without the excretory phase image of CT urography. Methods: A brief discussion of CT urography technique and dose reduction is followed by several cases illustrating the utility of CT urography. Results: CT urography has become the primary imaging modality for evaluation of hematuria, as well as in the staging and surveillance of urinary tract malignancies. CT urography includes a non-contrast phase and contrast-enhanced nephrographic and excretory (delayed) phases. While the three phases add to the diagnostic ability of CT urography, it also adds potential patient radiation dose. Several techniques including automatic exposure control, iterative reconstruction algorithms, higher noise tolerance, and split-bolus have been successfully used to mitigate dose. The excretory phase is timed such that the excreted contrast opacifies the urinary collecting system and allows for greater detection of filling defects or other abnormalities. Sixteen cases illustrating the utility of excretory phase imaging are reviewed. Conclusions: Excretory phase imaging of CT urography can be an essential tool for detecting and appropriately characterizing urinary tract malignancies, renal papillary and medullary abnormalities, CT radiolucent stones, congenital abnormalities, certain chronic inflammatory conditions, and perinephric collections.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation exposure and dose estimates for a nuclear-powered manned Mars sprint mission

A conceptual manned mission to Mars is analyzed in order to estimate potential ionizing radiation doses that may be incurred by crew members during the course of the mission. The scenario is set for a journey during the solar active period and includes a brief stay on the Martian surface. Propulsion is assumed to be provided by nuclear thermal rocket power, and estimates of the dose contributions from the reactors are included. However, due to effective shielding of the reactors by large propellant tanks, it is found that the incurred doses are principally due to the charged particle natural environment. Recent data (August-December 1989) for large solar proton events are used to simulate the flame environment, while standard models are used for the trapped particle and galactic cosmic ray contributions. Shield effectiveness for several candidate materials are investigated.

Nealy, John E.↗

Development of a Porcine Delayed Wound-Healing Model and Its Use in Testing a Novel Cell-Based Therapy

Purpose: A delayed full-thickness wound-healing model was developed and used for examining the capacity of adipose-derived stem cells (ASCs), either alone or in platelet-rich fibrin gels, to promote healing. Methods and Materials: Four pigs received electron beam radiation to the dorsal skin surface. Five weeks after radiation, subcutaneous fat was harvested from nonirradiated areas and processed to yield ASCs. Two weeks later, 28 to 30 full-thickness 1.5-cm{sup 2} wounds were made in irradiated and nonirradiated skin. Wounds were treated with either saline solution, ASCs in saline solution, platelet-rich plasma (PRP) fibrin gel, ASCs in PRP, or non-autologous green fluorescence protein-labeled ASCs. Results: The single radiation dose produced a significant loss of dermal microvasculature density (75%) by 7 weeks. There was a significant difference in the rate of healing between irradiated and nonirradiated skin treated with saline solution. The ASCs in PRP-treated wounds exhibited a significant 11.2% improvement in wound healing compared with saline solution. Enhancement was dependent on the combination of ASCs and PRP, because neither ASCs nor PRP alone had an effect. Conclusions: We have created a model that simulates the clinically relevant late radiation effects of delayed wound healing. Using this model, we showed that a combination of ASCs and PRP improves the healing rates of perfusion-depleted tissues, possibly through enhancing local levels of growth factors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nuclear imaging of the breast: Translating achievements in instrumentation into clinical use

Approaches to imaging the breast with nuclear medicine and/or molecular imaging methods have been under investigation since the late 1980s when a technique called scintimammography was first introduced. This review charts the progress of nuclear imaging of the breast over the last 20 years, covering the development of newer techniques such as breast specific gamma imaging, molecular breast imaging, and positron emission mammography. Key issues critical to the adoption of these technologies in the clinical environment are discussed, including the current status of clinical studies, the efforts at reducing the radiation dose from procedures associated with these technologies, and the relevant radiopharmaceuticals that are available or under development. The necessary steps required to move these technologies from bench to bedside are also discussed.

60 APPLIED LIFE SCIENCES↗

A New Orally Active, Aminothiol Radioprotector-Free of Nausea and Hypotension Side Effects at Its Highest Radioprotective Doses

Purpose: A new aminothiol, PrC-210, was tested for orally conferred radioprotection (rats, mice; 9.0 Gy whole-body, which was otherwise lethal to 100% of the animals) and presence of the debilitating side effects (nausea/vomiting, hypotension/fainting) that restrict use of the current aminothiol, amifostine (Ethyol, WR-2721). Methods and Materials: PrC-210 in water was administered to rats and mice at times before irradiation, and percent-survival was recorded for 60 days. Subcutaneous (SC) amifostine (positive control) or SC PrC-210 was administered to ferrets (Mustela putorius furo) and retching/emesis responses were recorded. Intraperitoneal amifostine (positive control) or PrC-210 was administered to arterial cannulated rats to score drug-induced hypotension. Results: Oral PrC-210 conferred 100% survival in rat and mouse models against an otherwise 100% lethal whole-body radiation dose (9.0 Gy). Oral PrC-210, administered by gavage 30-90 min before irradiation, conferred a broad window of radioprotection. The comparison of PrC-210 and amifostine side effects was striking because there was no retching or emesis in 10 ferrets treated with PrC-210 and no induced hypotension in arterial cannulated rats treated with PrC-210. The tested PrC-210 doses were the ferret and rat equivalent doses of the 0.5 maximum tolerated dose (MTD) PrC-210 dose in mice. The human equivalent of this mouse 0.5 MTD PrC-210 dose would likely be the highest PrC-210 dose used in humans. By comparison, the mouse 0.5 MTD amifostine dose, 400 {mu}g/g body weight (equivalent to the human amifostine dose of 910 mg/m{sup 2}), when tested at equivalent ferret and rat doses in the above models produced 100% retching/vomiting in ferrets and 100% incidence of significant, progressive hypotension in rats. Conclusions: The PrC-210 aminothiol, with no detectable nausea/vomiting or hypotension side effects in these preclinical models, is a logical candidate for human drug development to use in healthy humans in a wide variety of radioprotection settings, including medical radiation, space travel, and nuclear accidents.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation-Induced Cataractogenesis: A Critical Literature Review for the Interventional Radiologist

Extensive research supports an association between radiation exposure and cataractogenesis. New data suggests that radiation-induced cataracts may form stochastically, without a threshold and at low radiation doses. We first review data linking cataractogenesis with interventional work. We then analyze the lens dose typical of various procedures, factors modulating dose, and predicted annual dosages. We conclude by critically evaluating the literature describing techniques for lens protection, finding that leaded eyeglasses may offer inadequate protection and exploring the available data on alternative strategies for cataract prevention.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simultaneous {sup 68}Ga-DOTATOC-PET/MRI for IMRT Treatment Planning for Meningioma: First Experience

Purpose: To evaluate intensity-modulated radiotherapy (IMRT) treatment planning based on simultaneous positron-emission tomography and magnetic resonance imaging (PET/MRI) of meningioma. Methods and Materials: A meningioma patient was examined prior to radiotherapy with dedicated planning computed tomography (CT), MRI, PET/CT with gallium-68-labeled DOTATOC ({sup 68}Ga-DOTATOC), and simultaneous {sup 68}Ga-DOTATOC-PET/MRI. The first gross target volume (GTV) was defined based on a combination of separate MR and {sup 68}Ga-DOTATOC-PET/CT imaging (GTV{sub PET/CT+MR}). Then, the simultaneous PET/MR images were used to delineate a second GTV (GTV{sub PET/MR}) by following exactly the same delineation strategy. After an isotropic expansion of those volumes by a 4-mm safety margin, the resulting planning target volumes (PTVs) were compared by calculating the intersection volume and the relative complements. A cross-evaluation of IMRT plans was performed, where the treatment plan created for the PTV{sub PET/CT+MR} was applied to the PET/MR-based PTV{sub PET/MR}. Results: Generally, target volumes for IMRT treatment planning did not differ between MRI plus {sup 68}Ga-DOTATOC-PET/CT and simultaneous PET/MR imaging. Only in certain regions of the GTV were differences observed. The overall volume of the PET/MR-based PTV was approximately the same as that obtained from PET/CT data. A small region of infiltrative tumor growth next to the main tumor mass was better visualized with combined PET/MR due to smaller PET voxel sizes and improved recovery. An IMRT treatment plan was optimized for the PTV{sub PET/CT+MR}. The evaluation of this plan with respect to the PTV{sub PET/MR} showed parts of the target volume that would not have received the full radiation dose after delineation of the tumor, based on simultaneous PET/MR. Conclusion: This case showed that differences in target volumes delineated on the basis of separate MR and PET/CT and simultaneous PET/MR may be observed that can have significant consequences for an effectively applied radiotherapy treatment plan.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantifying the gantry sag on linear accelerators and introducing an MLC-based compensation strategy

Purpose: Gantry sag is one of the well-known sources of mechanical imperfections that compromise the spatial accuracy of radiation dose delivery. The objectives of this study were to quantify the gantry sag on multiple linear accelerators (linacs), to investigate a multileaf collimator (MLC)-based strategy to compensate for gantry sag, and to verify the gantry sag and its compensation with film measurements. Methods: The authors used the Winston-Lutz method to measure gantry sag on three Varian linacs. A ball bearing phantom was imaged with megavolt radiation fields at 10 deg. gantry angle intervals. The images recorded with an electronic portal imaging device were analyzed to derive the radiation isocenter and the gantry sag, that is, the superior-inferior wobble of the radiation field center, as a function of the gantry angle. The authors then attempted to compensate for the gantry sag by applying a gantry angle-specific correction to the MLC leaf positions. The gantry sag and its compensation were independently verified using film measurements. Results: Gantry sag was reproducible over a six-month measurement period. The maximum gantry sag was found to vary from 0.7 to 1.0 mm, depending on the linac and the collimator angle. The radiation field center moved inferiorly (i.e., away from the gantry) when the gantry was rotated from 0 deg. to 180 deg. After the MLC leaf position compensation was applied at 90 deg. collimator angle, the maximum gantry sag was reduced to <0.2 mm. The film measurements at gantry angles of 0 deg. and 180 deg. verified the inferior shift of the radiation fields and the effectiveness of MLC compensation. Conclusions: The results indicate that gantry sag on a linac can be quantitatively measured using a simple phantom and an electronic portal imaging device. Reduction of gantry sag is feasible by applying a gantry angle-specific correction to MLC leaf positions at 90 deg. collimator angle.

61 RADIATION PROTECTION AND DOSIMETRY↗

TU-G-201-00: Imaging Equipment Specification and Selection in Radiation Oncology Departments

This session will update therapeutic physicists on technological advancements and radiation oncology features of commercial CT, MRI, and PET/CT imaging systems. Also described are physicists’ roles in every stage of equipment selection, purchasing, and operation, including defining specifications, evaluating vendors, making recommendations, and optimal and safe use of imaging equipment in radiation oncology environment. The first presentation defines important terminology of CT and PET/CT followed by a review of latest innovations, such as metal artifact reduction, statistical iterative reconstruction, radiation dose management, tissue classification by dual energy CT and spectral CT, improvement in spatial resolution and sensitivity in PET, and potentials of PET/MR. We will also discuss important technical specifications and items in CT and PET/CT purchasing quotes and their impacts. The second presentation will focus on key components in the request for proposal for a MRI simulator and how to evaluate vendor proposals. MRI safety issues in radiation Oncology, including MRI scanner Zones (4-zone design), will be discussed. Basic MR terminologies, important functionalities, and advanced features, which are relevant to radiation therapy, will be discussed. In the third presentation, justification of imaging systems for radiation oncology, considerations in room design and construction in a RO department, shared use with diagnostic radiology, staffing needs and training, clinical/research use cases and implementation, will be discussed. The emphasis will be on understanding and bridging the differences between diagnostic and radiation oncology installations, building consensus amongst stakeholders for purchase and use, and integrating imaging technologies into the radiation oncology environment. Learning Objectives: Learn the latest innovations of major imaging systems relevant to radiation therapy Be able to describe important technical specifications of CT, MRI, and PET/CT Understand the process of budget request, equipment justification, comparisons of technical specifications, site visits, vendor selection, and contract development.

60 APPLIED LIFE SCIENCES↗

TU-G-201-01: What Therapy Physicists Need to Know About CT and PET/CT: Terminology and Latest Developments

This session will update therapeutic physicists on technological advancements and radiation oncology features of commercial CT, MRI, and PET/CT imaging systems. Also described are physicists’ roles in every stage of equipment selection, purchasing, and operation, including defining specifications, evaluating vendors, making recommendations, and optimal and safe use of imaging equipment in radiation oncology environment. The first presentation defines important terminology of CT and PET/CT followed by a review of latest innovations, such as metal artifact reduction, statistical iterative reconstruction, radiation dose management, tissue classification by dual energy CT and spectral CT, improvement in spatial resolution and sensitivity in PET, and potentials of PET/MR. We will also discuss important technical specifications and items in CT and PET/CT purchasing quotes and their impacts. The second presentation will focus on key components in the request for proposal for a MRI simulator and how to evaluate vendor proposals. MRI safety issues in radiation Oncology, including MRI scanner Zones (4-zone design), will be discussed. Basic MR terminologies, important functionalities, and advanced features, which are relevant to radiation therapy, will be discussed. In the third presentation, justification of imaging systems for radiation oncology, considerations in room design and construction in a RO department, shared use with diagnostic radiology, staffing needs and training, clinical/research use cases and implementation, will be discussed. The emphasis will be on understanding and bridging the differences between diagnostic and radiation oncology installations, building consensus amongst stakeholders for purchase and use, and integrating imaging technologies into the radiation oncology environment. Learning Objectives: Learn the latest innovations of major imaging systems relevant to radiation therapy Be able to describe important technical specifications of CT, MRI, and PET/CT Understand the process of budget request, equipment justification, comparisons of technical specifications, site visits, vendor selection, and contract development.

60 APPLIED LIFE SCIENCES↗

TU-G-201-02: An MRI Simulator From Proposal to Operation

This session will update therapeutic physicists on technological advancements and radiation oncology features of commercial CT, MRI, and PET/CT imaging systems. Also described are physicists’ roles in every stage of equipment selection, purchasing, and operation, including defining specifications, evaluating vendors, making recommendations, and optimal and safe use of imaging equipment in radiation oncology environment. The first presentation defines important terminology of CT and PET/CT followed by a review of latest innovations, such as metal artifact reduction, statistical iterative reconstruction, radiation dose management, tissue classification by dual energy CT and spectral CT, improvement in spatial resolution and sensitivity in PET, and potentials of PET/MR. We will also discuss important technical specifications and items in CT and PET/CT purchasing quotes and their impacts. The second presentation will focus on key components in the request for proposal for a MRI simulator and how to evaluate vendor proposals. MRI safety issues in radiation Oncology, including MRI scanner Zones (4-zone design), will be discussed. Basic MR terminologies, important functionalities, and advanced features, which are relevant to radiation therapy, will be discussed. In the third presentation, justification of imaging systems for radiation oncology, considerations in room design and construction in a RO department, shared use with diagnostic radiology, staffing needs and training, clinical/research use cases and implementation, will be discussed. The emphasis will be on understanding and bridging the differences between diagnostic and radiation oncology installations, building consensus amongst stakeholders for purchase and use, and integrating imaging technologies into the radiation oncology environment. Learning Objectives: Learn the latest innovations of major imaging systems relevant to radiation therapy Be able to describe important technical specifications of CT, MRI, and PET/CT Understand the process of budget request, equipment justification, comparisons of technical specifications, site visits, vendor selection, and contract development.

60 APPLIED LIFE SCIENCES↗

TU-G-201-03: Imaging Systems in Radiotherapy: Buying, Installing, and Using

This session will update therapeutic physicists on technological advancements and radiation oncology features of commercial CT, MRI, and PET/CT imaging systems. Also described are physicists’ roles in every stage of equipment selection, purchasing, and operation, including defining specifications, evaluating vendors, making recommendations, and optimal and safe use of imaging equipment in radiation oncology environment. The first presentation defines important terminology of CT and PET/CT followed by a review of latest innovations, such as metal artifact reduction, statistical iterative reconstruction, radiation dose management, tissue classification by dual energy CT and spectral CT, improvement in spatial resolution and sensitivity in PET, and potentials of PET/MR. We will also discuss important technical specifications and items in CT and PET/CT purchasing quotes and their impacts. The second presentation will focus on key components in the request for proposal for a MRI simulator and how to evaluate vendor proposals. MRI safety issues in radiation Oncology, including MRI scanner Zones (4-zone design), will be discussed. Basic MR terminologies, important functionalities, and advanced features, which are relevant to radiation therapy, will be discussed. In the third presentation, justification of imaging systems for radiation oncology, considerations in room design and construction in a RO department, shared use with diagnostic radiology, staffing needs and training, clinical/research use cases and implementation, will be discussed. The emphasis will be on understanding and bridging the differences between diagnostic and radiation oncology installations, building consensus amongst stakeholders for purchase and use, and integrating imaging technologies into the radiation oncology environment. Learning Objectives: Learn the latest innovations of major imaging systems relevant to radiation therapy Be able to describe important technical specifications of CT, MRI, and PET/CT Understand the process of budget request, equipment justification, comparisons of technical specifications, site visits, vendor selection, and contract development.

60 APPLIED LIFE SCIENCES↗