Search NASA⌕ Search

SEARCH · Search NASA

Results for “Rejection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

High performance CaS solar-blind ultraviolet photodiodes fabricated by seed-layer-assisted growth

CaS, with a direct bandgap of 5.38 eV, is expected to be a strong candidate as the active-layer of high performance solar-blind UV photodiodes that have important applications in both civilian and military sectors. Here, we report that a seed-layer-assisted growth approach via molecular beam epitaxy can result in high crystalline quality rocksalt CaS thin films on zincblende GaAs substrates. The Au/CaS/GaAs solar-blind photodiodes demonstrated , more than five orders in its visible rejection power, a photoresponse of 36.8 mA/w at zero bias and a corresponding quantum efficiency as high as 19% at 235 nm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Unraveling irradiation induced grain growth with in situ transmission electron microscopy and coordinated modeling

Nanostructuring has been proposed as a method to enhance radiation tolerance, but many metallic systems are rejected due to significant concerns regarding long term grain boundary and interface stability. This work utilized recent advancements in transmission electron microscopy (TEM) to quantitatively characterize the grain size, texture, and individual grain boundary character in a nanocrystalline gold model system before and after in situ TEM ion irradiation with 10 MeV Si. The initial experimental measurements were fed into a mesoscale phase field model, which incorporates the role of irradiation-induced thermal events on boundary properties, to directly compare the observed and simulated grain growth with varied parameters. The observed microstructure evolution deviated subtly from previously reported normal grain growth in which some boundaries remained essentially static. In broader terms, the combined experimental and modeling techniques presented herein provide future avenues to enhance quantification and prediction of the thermal, mechanical, or radiation stability of grain boundaries in nanostructured crystalline systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-performance ultraviolet detection and visible-blind photodetector based on Cu{sub 2}O/ZnO nanorods with poly-(N-vinylcarbazole) intermediate layer

This study reports a high-performance hybrid ultraviolet (UV) photodetector with visible-blind sensitivity fabricated by inserting a poly-(N-vinylcarbazole) (PVK) intermediate layer between low-cost processed Cu{sub 2}O film and ZnO nanorods (NRs). The PVK layer acts as an electron-blocking/hole-transporting layer between the n-ZnO and p-Cu{sub 2}O films. The Cu{sub 2}O/PVK/ZnO NR photodetector exhibited a responsivity of 13.28 A/W at 360 nm, a high detectivity of 1.03 × 10{sup 13} Jones at a low bias of −0.1 V under a low UV light intensity of 24.9 μW/cm{sup 2}. The photo-to-dark current ratios of the photodetector with and without the PVK intermediate layer at a bias of −0.5 V are 1.34 × 10{sup 2} and 3.99, respectively. The UV-to-visible rejection ratios (R{sub 360 nm}/R{sub 450 nm}) are 350 and 1.735, respectively. Several features are demonstrated: (a) UV photo-generated holes at the ZnO NRs can effectively be transported through the PVK layer to the p-Cu{sub 2}O layer; (b) the insertion of a PVK buffer layer significantly minimizes the reverse-bias leakage current, which leads to a larger amplification of the photocurrent; and (c) the PVK buffer layer greatly improves the UV-to-visible responsivity ratio, allowing the device to achieve high UV detection sensitivity at a low bias voltage using a very low light intensity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low-voltage harmonic multiplying gyrotron traveling-wave amplifier in G band

Harmonic multiplying operation in a gyrotron traveling-wave amplifier (gyro-TWA) permits for magnetic field reduction and frequency multiplication. Lowering a beam voltage is an important step toward miniaturization of a harmonic multiplying gyro-TWA. However, the additional degree of freedom that is provided by the multitude cyclotron harmonics in a low-voltage harmonic multiplying gyro-TWA still easily generates various competing modes. An improved mode-selective circuit, using circular waveguides with various radii, can provide the rejection points within the frequency range to suppress competing modes. Simulated results reveal that the mode-selective circuit can provide an attenuation of more than 14 dB to suppress the competing modes. Furthermore, the performance of the gyro-TWA is analyzed for studying the sensitivity of the saturated output power and full width at half maximum bandwidth of the gyro-TWA to the beam voltage and the magnetic field. A stable low-voltage harmonic multiplying gyro-TWA with the mode-selective circuit is predicted to yield a peak output power of 24 kW at 200.4 GHz, corresponding to a saturated gain of 56 dB at an interaction efficiency of 20%. The full width at half maximum bandwidth is 3.0 GHz.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Daniell method for power spectral density estimation in atomic force microscopy

An alternative method for power spectral density (PSD) estimation—the Daniell method—is revisited and compared to the most prevalent method used in the field of atomic force microscopy for quantifying cantilever thermal motion—the Bartlett method. Both methods are shown to underestimate the Q factor of a simple harmonic oscillator (SHO) by a predictable, and therefore correctable, amount in the absence of spurious deterministic noise sources. However, the Bartlett method is much more prone to spectral leakage which can obscure the thermal spectrum in the presence of deterministic noise. By the significant reduction in spectral leakage, the Daniell method leads to a more accurate representation of the true PSD and enables clear identification and rejection of deterministic noise peaks. This benefit is especially valuable for the development of automated PSD fitting algorithms for robust and accurate estimation of SHO parameters from a thermal spectrum.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The radiation protection principles model as a tool in the e-waste procedures

The electrical and electronic waste (e-waste) management is a global environmental problem dominated by the precautionary principle application, resulted to preliminary and ambiguous potential adverse effects, of extensive scientific uncertainty. In order to overcome the detected stochastic effects confusions in this field, we propose the inclusion of the principles of justification-optimization-limitation and of prudent avoidance. This model is already, established in radiation protection, so that toxicity as a result of the e-waste management would decrease, whilst the precious metals would be saved. We, further, resolve the classification of rejected items as reusable or as waste, so that the procedure of dismantling and recycling becomes easier, and the collecting-transporting-placement at an e-waste landfill would be safer. In conclusion, our proposing pattern in the e-waste management enforces the sustainable reducing-reusing-recycling, saves time/money and advances safety by including more sources of e-waste (military, medical etc) that were excluded previously.

54 ENVIRONMENTAL SCIENCES↗

Realization of highly efficient hexagonal boron nitride neutron detectors

Here, we report the achievement of highly efficient 10 B enriched hexagonal boron nitride (h- 10 BN) direct conversion neutron detectors. These detectors were realized from freestanding 4-in. diameter h- 10 BN wafers 43 μm in thickness obtained from epitaxy growth and subsequent mechanical separation from sapphire substrates. Both sides of the film were subjected to ohmic contact deposition to form a simple vertical “photoconductor-type” detector. Transport measurements revealed excellent vertical transport properties including high electrical resistivity (>10 13 Ω cm) and mobility-lifetime (μτ) products. A much larger μτ product for holes compared to that of electrons along the c-axis of h- BN was observed, implying that holes (electrons) behave like majority (minority) carriers in undoped h- BN. Exposure to thermal neutrons from a californium-252 ( 252 Cf) source moderated by a high density polyethylene moderator reveals that 43 μm h- 10 BN detectors possess 51.4% detection efficiency at a bias voltage of 400 V, which is the highest reported efficiency for any semiconductor-based neutron detector. The results point to the possibility of obtaining highly efficient, compact solid-state neutron detectors with high gamma rejection and low manufacturing and maintenance costs.

36 MATERIALS SCIENCE↗

Applying the new gamma ray imager diagnostic to measurements of runaway electron Bremsstrahlung radiation in the DIII-D Tokamak (invited)

A new gamma ray imager (GRI) is developed to probe the electron distribution function with 2D spatial resolution during runaway electron (RE) experiments at the DIII-D tokamak. The diagnostic is sensitive to 0.5–100 MeV gamma rays, allowing characterization of the RE distribution function evolution during RE growth and dissipation. The GRI consists of a lead “pinhole camera” mounted on the DIII-D midplane with 123 honeycombed tangential chords 20 cm wide that span the vessel interior. Up to 30 bismuth germanate (BGO) scintillation detectors capture RE bremsstrahlung radiation for Pulse Height Analysis (PHA) capable of discriminating up to 20 000 pulses per second. Digital signal processing routines combining shaping filters are performed during PHA to reject noise and record gamma ray energy. The GRI setup and PHA algorithms will be described and initial data from experiments will be presented. A synthetic diagnostic is developed to generate the gamma ray spectrum of a GRI channel given the plasma information and a prescribed distribution function. Magnetic reconstructions of the plasma are used to calculate the angle between every GRI sightline and orient and discriminate gamma rays emitted by a field-aligned RE distribution function.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel, cost-effective, multi-point Thomson scattering system on the Pegasus Toroidal Experiment (invited)

Here, a novel, cost-effective, multi-point Thomson scattering system has been designed, implemented, and operated on the Pegasus Toroidal Experiment. Leveraging advances in Nd:YAG lasers, high-efficiency volume phase holographic transmission gratings, and increased quantum-efficiency Generation 3 image-intensified charge coupled device (ICCD) cameras, the system provides Thomson spectra at eight spatial locations for a single grating/camera pair. The on-board digitization of the ICCD camera enables easy modular expansion, evidenced by recent extension from 4 to 12 plasma/background spatial location pairs. Stray light is rejected using time-of-flight methods suited to gated ICCDs, and background light is blocked during detector readout by a fast shutter. This –10 3 reduction in background light enables further expansion to up to 24 spatial locations. The implementation now provides single-shot T e (R) for n e > 5 × 10 18 m –3 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhanced configurational sampling with hybrid non-equilibrium molecular dynamics–Monte Carlo propagator

Molecular dynamics (MD) trajectories based on classical equations of motion can be used to sample the configurational space of complex molecular systems. However, brute-force MD often converges slowly due to the ruggedness of the underlying potential energy surface. Several schemes have been proposed to address this problem by effectively smoothing the potential energy surface. However, in order to recover the proper Boltzmann equilibrium probability distribution, these approaches must then rely on statistical reweighting techniques or generate the simulations within a Hamiltonian tempering replica-exchange scheme. The present work puts forth a novel hybrid sampling propagator combining Metropolis-Hastings Monte Carlo (MC) with proposed moves generated by non-equilibrium MD (neMD). This hybrid neMD-MC propagator comprises three elementary elements: (i) an atomic system is dynamically propagated for some period of time using standard equilibrium MD on the correct potential energy surface; (ii) the system is then propagated for a brief period of time during what is referred to as a “boosting phase,” via a time-dependent Hamiltonian that is evolved toward the perturbed potential energy surface and then back to the correct potential energy surface; (iii) the resulting configuration at the end of the neMD trajectory is then accepted or rejected according to a Metropolis criterion before returning to step 1. A symmetric two-end momentum reversal prescription is used at the end of the neMD trajectories to guarantee that the hybrid neMD-MC sampling propagator obeys microscopic detailed balance and rigorously yields the equilibrium Boltzmann distribution. The hybrid neMD-MC sampling propagator is designed and implemented to enhance the sampling by relying on the accelerated MD and solute tempering schemes. It is also combined with the adaptive biased force sampling algorithm to examine. Illustrative tests with specific biomolecular systems indicate that the method can yield a significant speedup.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Light propagation in a neutron detector based on 6 Li glass scintillator particles in an organic matrix

Composite materials consisting of 6 Li scintillator particles in an organic matrix can enable thermal neutron detectors with excellent rejection of gamma-ray backgrounds. The efficiency of transporting scintillation light through such a composite is critical to the detector performance. This optical raytracing study of a composite thermal neutron detector quantifies the various sources of scintillation light loss and identifies favorable photomultiplier tube (PMT) readout schemes. The composite material consisted of scintillator cubes within an organic matrix shaped as a right cylinder. The cylinder surface was surrounded by an optical reflector, and the light was detected by PMTs attached to the cylinder end faces. A reflector in direct contact with the composite caused 53% loss of scintillation light. This loss was reduced 8-fold by creating an air gap between the composite and the reflector to allow a fraction of the scintillation light to propagate by total internal reflection. Replacing a liquid mineral oil matrix with a solid acrylic matrix decreased the light transport efficiency by only ~10% for the benefit of creating an all-solid-state device. The light propagation loss was found to scale exponentially with the distance between the scintillation event and the PMT along the cylinder main axis. This enabled a PMT readout scheme that corrects for light propagation loss on an event-by-event basis and achieved a 4.0% energy resolution that approached Poisson-limited performance. These results demonstrate that composite materials can enable practical thermal neutron detectors for a wide range of nuclear non-proliferation and safeguard applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hammerhead, an ultrahigh resolution ePix camera for wavelength-dispersive spectrometers

Wavelength-dispersive spectrometers (WDS) are often used in synchrotron and FEL applications where high energy resolution (in the order of eV) is important. Increasing WDS energy resolution requires increasing spatial resolution of the detectors in the dispersion direction. The common approaches are not ideal: using strip detectors loses the 2D position sensitivity (important for, e.g., background estimation) and the high counting rate; using pixel detectors with a small pitch results in complex charge sharing behaviour and typically have a small size. Developing pixel detectors with high aspect ratio and a small pitch in the wavelength dispersive direction would be ideal, however, it would require a substantial ASIC development. We present a new approach, with a novel sensor design using rectangular pixels with a high aspect ratio (between strips and pixels, further called “strixels”), and strixel redistribution to match the square pixel arrays of typical ASICs. This results in a sensor area of 17.4 mm × 77 mm, with a fine pitch of 25 µm in the horizontal direction resulting in 3072 columns and 176 rows. The sensors use ePix100 readout ASICs, leveraging their low noise (43 e - , or 180 eV rms). We present results obtained with a Hammerhead ePix100 camera, showing that the small pitch (25 µm) in the dispersion direction maximizes performance for both high and low photon occupancies, resulting in optimal WDS energy resolution. The low noise level at high photon occupancy allows precise photon counting, while at low occupancy, both the energy and the subpixel position can be reconstructed for every photon, allowing an ultrahigh resolution (in the order of 1 µm) in the dispersion direction and rejection of scattered beam and harmonics. Using strixel sensors with redistribution and flip-chip bonding to standard ePix readout ASICs results in ultrahigh position resolution (~1 µm) and low noise in WDS applications, leveraging the advantages of hybrid pixel detectors (high production yield, good availability, relatively inexpensive) while minimizing development complexity through sharing the ASIC, hardware, software and DAQ development with other versions of ePix cameras.

47 OTHER INSTRUMENTATION↗

Radiative cooling resource maps for the contiguous United States

Passive cooling devices take advantage of the partially transparent properties of the atmosphere in the longwave spectral band from 8 to 13 μ m (the so-called “atmospheric window”) to reject radiation to outer space. Spectrally designed thermophotonic devices have raised substantial attention recently for their potential to provide passive and carbon-free alternatives to air conditioning. However, the level of transparency of the atmospheric window depends on the local content of water vapor in the atmosphere and on the optical depth of clouds in the local sky. Thus, the radiative cooling capacity of solar reflectors not only depends on the optical properties of their surfaces but also on local meteorological conditions. In this work, detailed radiative cooling resource maps for the contiguous United States are presented with the goal of determining the best climates for large-scale deployment of passive radiative cooling technologies. The passive cooling potential is estimated based on ideal optical properties, i.e., zero shortwave absorptance (maximum reflectance) and blackbody longwave emittance. Both annual and season-averaged maps are presented. Daytime and nighttime cooling potential are also computed and compared. The annual average cooling potential over the contiguous United States is 50.5 m -2 . The southwestern United States has the highest annual averaged cooling potential, over 70 W m -2 , due to its dry and mostly clear sky meteorological conditions. The southeastern United States has the lowest potential, around 30 W m -2 , due to frequent humid and/or overcast weather conditions. In the spring and fall months, the Arizona and New Mexico climates provide the highest passive cooling potential, while in the summer months, Nevada and Utah exhibit higher potentials. Passive radiative cooling is primarily effective in the western United States, while it is mostly ineffective in humid and overcast climates elsewhere.

Thermo optic effects↗

A study of defect structures in Fe-alloyed ZnO: Morphology, magnetism, and hyperfine interactions

In order to study the effect of Fe cation substitution on the local structure, defect formation, and hyperfine interactions in ZnO, Mössbauer spectroscopy measurements of the microwave processed Zn 1 - x Fe x O (x = 0.05, 0.10, 0.15, and 0.20) nanoparticles, together with ab initio calculations, were performed. Complementary information on the distribution of particle size and morphology, as well as magnetic properties, were obtained by X-ray diffraction, transmission electron microscopy, and squid-magnetometry. The selected model for analyzing the Mössbauer spectra of our samples is a distribution of quadrupole splittings. The fitting model with two Lorentz doublets was rejected due to its failure to include larger doublets. The Fe 3 + ions do not yield magnetic ordering in the samples at room temperature. The results from first-principles calculations confirm that the major component of the Mössbauer spectra corresponds to the Fe-alloyed ZnO with Zn vacancy in the next nearest neighbor environment. The magnetic measurements are consistent with the description of the distribution of iron ions over the randomly formed clusters in the ZnO host lattice. While at room temperature all the samples are paramagnetic, magnetic interactions cause a transition into a cluster spin-glass state at low temperatures. © 2019 Author(s).

60 APPLIED LIFE SCIENCES↗

Frequency-domain hot-wire sensor and 3D model for thermal conductivity measurements of reactive and corrosive materials at high temperatures

High temperature solids and liquids are becoming increasingly important in next-generation energy and manufacturing systems that seek higher efficiencies and lower emissions. Accurate measurements of thermal conductivity at high temperatures are required for the modeling and design of these systems, but commonly employed time-domain measurements can have errors from convection, corrosion, and ambient temperature fluctuations. Here, we describe the development of a frequency-domain hot-wire technique capable of accurately measuring the thermal conductivity of solid and molten compounds from room temperature up to 800 °C. Therefore, by operating in the frequency-domain, we can lock into the harmonic thermal response of the material and reject the influence of ambient temperature fluctuations, and we can keep the probed volume below 1 µl to minimize convection. The design of the microfabricated hot-wire sensor, electrical systems, and insulating wire coating to protect against corrosion is covered in detail. Furthermore, we discuss the development of a full three-dimensional multilayer thermal model that accounts for both radial conduction into the sample and axial conduction along the wire and the effect of wire coatings. The 3D, multilayer model facilitates the measurement of small sample volumes important for material development. A sensitivity analysis and an error propagation calculation of the frequency-domain thermal model are performed to demonstrate what factors are most important for thermal conductivity measurements. Finally, we show thermal conductivity measurements including model data fitting on gas (argon), solid (sulfur), and molten substances over a range of temperatures.

47 OTHER INSTRUMENTATION↗

Validation of heat transport modeling using directly driven beryllium spheres

Recent experiments involving directly driven beryllium spheres are reported. Plasma conditions are measured using Thomson scattering with the probe beam pointed 200, 300, and 400 μ m from the surface of the sphere. Laser coupling is assessed using calorimeters that collect scattered light placed at various locations within the target chamber. Laser intensities of 1 0 14 W / c m 2 and 2.5 × 1 0 14 W / c m 2 are chosen to minimize unmodeled laser-plasma interactions (LPIs) that lead to laser-target decoupling. Two-dimensional simulations are compared to the interpreted data using the radiation-hydrodynamics code Lasnex. Heat transport is simulated using flux-limited Spitzer–Harm with both high ( f = 0.15) and low ( f = 0.03) flux limiters and the Schurtz–Nicolai-Busquet (SNB) model. At 1 0 14 W / c m 2 , all three heat transport models agree well with the measurement, demonstrating that the heat flux is local at low intensities near the measurement locations. At 2.5 × 1 0 14 W / c m 2 , the SNB and high flux model roughly match the plasma conditions but predict 2% uncoupled light compared to 10% measured. Additionally, the use of drive multipliers to match the measured coupled light does not alter the agreement between measured and simulated plasma conditions, suggesting that decoupling due to LPI is unlikely to alter this agreement. The low flux model cannot match the plasma conditions and results in 19% scattered light. The use of a resonant absorption model can be used to bring the simulated scattered light into agreement, but the simulated plasma conditions are still in disagreement with the measurement. For this reason, the low flux model is rejected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A 1D Lyman-alpha profile camera for plasma edge neutral studies on the DIII-D tokamak

A one dimensional, absolutely calibrated pinhole camera system was installed on the DIII-D tokamak to measure edge Lyman-alpha (Ly-α) emission from hydrogen isotopes, which can be used to infer neutral density and ionization rate profiles. The system is composed of two cameras, each providing a toroidal fan of 20 lines of sight, viewing the plasma edge on the inboard and outboard side of DIII-D. The cameras’ views lie in a horizontal plane 77 cm below the midplane. At its tangency radius, each channel provides a radial resolution of ~2 cm full width at half maximum (FWHM) with a total coverage of 22 cm. Each camera consists of a rectangular pinhole, Ly-α reflective mirror, narrow-band Ly-α transmission filter, and a 20 channel AXUV photodetector. The combined mirror and transmission filter have a FWHM of 5 nm, centered near the Ly-α wavelength of 121.6nm and is capable of rejecting significant, parasitic carbon-III (C-III) emission from intrinsic plasma impurities. To provide a high spatial resolution measurement in a compact footprint, the camera utilizes advanced engineering and manufacturing techniques including 3D printing, high stability mirror mounts, and a novel alignment procedure. Absolutely calibrated, spatially resolved Ly-α brightness measurements utilize a bright, isolated line with low parasitic surface reflections and enable quantitative comparison to modeling to study divertor neutral leakage, main chamber fueling, and radial particle transport.

Ionization Rate↗

Radio frequency mixing modules for superconducting qubit room temperature control systems

As the number of qubits in nascent quantum processing units increases, the connectorized RF (radio frequency) analog circuits used in first generation experiments become exceedingly complex. The physical size, cost, and electrical failure rate all become limiting factors in the extensibility of control systems. We have developed a series of compact RF mixing boards to address this challenge by integrating I/Q quadrature mixing, intermediate frequency/LO (local oscillator)/RF power level adjustments, and direct current bias fine tuning on a 40 × 80 mm 2 four-layer printed circuit board with electromagnetic interference shielding. The RF mixing module is designed to work with RF and LO frequencies between 2.5 and 8.5 GHz. The typical image rejection and adjacent channel isolation are measured to be ~27 dBc and ~50 dB. By scanning the drive phase in a loopback test, the module short-term amplitude and phase linearity are typically measured to be 5 ×10 -4 (V pp /V mean ) and 1 ×10 -3 radian (pk-pk). The operation of the RF mixing board was validated by integrating it into the room temperature control system of a superconducting quantum processor and executing randomized benchmarking characterization of single and two qubit gates. We measured a single-qubit process infidelity of 9.3(3) × 10 -4 and a two-qubit process infidelity of 2.7(1) × 10 -2 .

47 OTHER INSTRUMENTATION↗