Search NASA⌕ Search

SEARCH · Search NASA

Results for “Signal generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Free-Flying Magnetometer Data System

The Free-Flying Magnetometer (FFM) is an autonomous "sensorcraft" developed at the Jet Propulsion Laboratory (JPL) for the Enstrophy sounding rocket mission. This mission was a collaborative project between the University of New Hampshire, Cornell University and JPL. The science goal of the mission was the study of current filamentation phenomena in the northern auroral region through multipoint measurements of magnetic field. The technical objective of the mission was the proof of concept of the JPL FFM design and the demonstration of an in-situ multipoint measurement technique employing many free-flying spacecraft. Four FFMs were successfully deployed from a sounding rocket launched from Poker Flats, Alaska on February 11, 1999. These hockey-puck-sized (80 mm diameter, 38 mm. height, 250 gram mass) free flyers each carry a miniature 3-axis flux-gate magnetometer that output +/- 2 V signals corresponding to a +/- 60,000 nT measurement range for each axis. The FFM uses a synchronized four-channel Sigma(Delta) Analog-to-Digital Converter (ADC) having a dynamic range of +/- 2.5V and converting at a rate of 279 samples/second/channel. Three channels are used to digitize the magnetometer signals to 17-bit (1.144 nT/bit) resolution. The fourth ADC channel is multiplexed for system monitoring of four temperature sensors and two battery voltages. The FFM also contains two sun sensors, a laser diode which emits a fan-shaped beam, a miniature S-band transmitter for direct communication to the ground station antennas, an ultra-stable Temperature Compensated Crystal Oscillator (TCXO) clock, an integrated data subsystem implemented in a Field-Programmable Gate Array (FPGA), a 4 Mbit Static Random Access Memory (SRAM) for data storage and Lithium Thionyl Chloride batteries for power. Communicating commands to the FFM prior to deployment is achieved with an infrared (IR) link. The FFM IR receiver responds to 9-bit pulse coded signals that are generated by an IR Light Emitting Diode (LED) in the payload for turning FFM power on or off and placing the FFM in a test mode or flight mode. The IR links are also used to synchronize (zero) the clocks onboard all the FFMs through a reset pulse originating from the payload GPS receiver that is issued when the FFMs are in flight mode. The FPGA based data subsystem manages continuous data collection from the four ADC channels and sun sensors, formatting and storing the data to SRAM, and controlling downlink transmission. The transmitter is powered only after a 2547 frame SRAM buffer has been filled (approx. 5 minutes of data). The data is Viterbi encoded and sent to the S-band transmitter via a First-In-First-Out (FIFO) buffer who's output is clocked at 100 bits/second. After the 26-second transmission, the transmitter is turned off to reduce noise coupling to the sensitive magnetometer. The data subsystem control consists of a master state machine that performs data flow management and is interfaced through a prioritized interrupt scheme to state machines that service the ADC, sun sensors and transmitter FIFO. Continuous data collection prevents the missing of data during transmission and provides implicit time tagging of the data acquired by the ADC because of synchronization with the TCXO clock.

Blaes, B.↗

Ecosystem Modeling of Biological Processes to Global Budgets

From an ecological perspective, the search for life on distant planets begins from several key assumptions. The first of these is that, viewed from a remote location in space, the signature of life on a distant planet will be the result of net gas exchange of organisms with their environment. On the basis of extensive biogeochemical measurements and biogenic trace gas fluxes in modem Earth environments, it is probable that certain groups of organisms both produce and consume the same trace gas(es) within a single bioprofile of Solid (porous) substrate or surface water. The net gas exchange rate with the atmosphere measured at the living surface is frequently the result of competing metabolic reactions, which may carried out by different functional groups of organisms located at dissimilar 'climatic' or chemical microsites within the same bioprofile. Biogenic gases produced at one (deep) level of a bioprofile may be consumed by another functional group of organisms located closer to the level of surface exchange with the atmosphere. A second key assumption is that the net biogenic fluxes of atmospheric gases on Earth can be used to infer relative abundance and functional composition of the major organisms on a distant planet. Examples of this principle include the presence of methanogenic microorganisms abundant today in freshwater ecosystems worldwide, which are major source of atmospheric methane and its seasonal variability in Earth's atmosphere. A third assumption is that scaling up biogenic gas fluxes from a single biological community to the planetary level requires flux measurements at the whole ecosystem level. This implies that measurements of biogenic gas exchange with the global atmosphere cannot be easily inferred from measurements of gas production rates of single organisms, which may have been isolated in some manner from the setting of their native ecosystem. Hence, the unit of biological organization used in modern Earth Science for scaling up to biosphere effects on atmospheric composition is the ecosystem level. These assumptions are the foundation for developing modern emission budgets for biogenic gases such as carbon dioxide, methane, carbon monoxide, isoprene, nitrous and nitric oxide, and ammonia. Such emission budgets commonly include information on seasonal flux patterns, typical diurnal profiles, and spatial resolution of at least one degree latitude/longitude for the globe. On the basis of these budgets, it is possible to compute 'base emission rates' for the major biogenic trace gases from both terrestrial and ocean sources, which may be useful benchmarks for defining the gas production rates of organisms, especially those from early Earth history, which are required to generate a detectable signal on a global atmosphere. This type of analysis is also the starting point for evaluation of the 'biological processes to global gas budget' extrapolation procedure described above for early Earth ecosystems.

Christopher, Potter S.↗

Albedo in the ATIC Experiment

ATIC(Advanced Thin Ionization Calorimeter) is a balloon borne experiment designed to measure the cosmic ray composition for elements from hydrogen to iron and their energy spectra from approx.50 GeV to near 100 TeV. It consists of a Si-matrix detector to determine the charge of a CR particle, a scintillator hodoscope for tracking, carbon interaction targets and a fully active BGO calorimeter. ATIC had its first 16-day flight from McMurdo, Antarctica from 28/12/2000 to 13/01/2000. The ATIC flight collected approximately 25 million events. To measure charge of primary particle in presence of radiation scattered back from the interaction and subsequent shower development in the calorimeter a charge detector must be a mosaic of small detector pads so that the pad containing the signal from the incident particle has no additional signal from albedo particles. Therefore the silicon matrix was built of 4480 individual silicon pads each 2 cm x 1.5 cm. The matrix consists of four planes of detectors and the active detector area, in these planes are partially overlapped to completely cover the aperture. The lateral and amplitude distributions of albedo signals in Si-matrix are analyzed for different primary nuclei and different energy deposits in BGO calorimeter. The greater part of albedo signals has Q near 1, where Q = square root of Amplitude(MIP). The albedo distribution exponentially decreases up to Q near 8. These high values are produced by slow protons and plans. There are also a small number of signals of Q > 8, mainly for heavy nucleus primaries. These signals are apparently generated by neutrons. The comparison of the experimental data and simulations with GEANT 3-21 code using QGSM generator for nucleus-nucleus interactions is presented.

Sokolskaya, N. V.↗

Self Injury Inhibitor

There are approximately 50,000 autistic and retarded people in the United States alone, and many of them engage in self-injurious behavior, principally compulsive headbanging. Hope is offered by an automated unit, manufactured at Johns Hopkins University, called the Self-Injurious Behavior Inhibiting System (SIBIS). Components of SIBIS are stimulus module which is worn on upper arm or leg, and headgear which includes an impact detector and a transmitter on back of head. When there is a blow to the head it is sensed by impact detector which generates a coded signal that is automatically transferred to stimulus module which delivers a mild electrical stimulus to the skin for less than 1/10 of a second. Stimulus is sufficient to halt headbanging. Microprocessor computes impacts allowing measurement of patient progress.

Source record↗

An Implementation of a Tracking Filter

For Goddard's new Matlab-based data analysis system, a Hilbert transform is used to generate a quadrature signal directly from the COLA signal. This differs from the usual practice of synthesizing the sine and cosine components after determining the sweep characteristics from the COLA signal. The original and quadrature signals are in turn mixed with the signal to be analyzed and then filtered to determine the frequency spectrum. This new technique appears to be more accurate in determining frequency and is insensitive to variations in COLA amplitude.

Worth, Daniel B.↗

Design and Flight Tests of an Adaptive Control System Employing Normal-Acceleration Command

An adaptive control system employing normal-acceleration command has been designed with the aid of an analog computer and has been flight tested. The design of the system was based on the concept of using a mathematical model in combination with a high gain and a limiter. The study was undertaken to investigate the application of a system of this type to the task of maintaining nearly constant dynamic longitudinal response of a piloted airplane over the flight envelope without relying on air data measurements for gain adjustment. The range of flight conditions investigated was between Mach numbers of 0.36 and 1.15 and altitudes of 10,000 and 40,000 feet. The final adaptive system configuration was derived from analog computer tests, in which the physical airplane control system and much of the control circuitry were included in the loop. The method employed to generate the feedback signals resulted in a model whose characteristics varied somewhat with changes in flight condition. Flight results showed that the system limited the variation in longitudinal natural frequency of the adaptive airplane to about half that of the basic airplane and that, for the subsonic cases, the damping ratio was maintained between 0.56 and 0.69. The system also automatically compensated for the transonic trim change. Objectionable features of the system were an exaggerated sensitivity of pitch attitude to gust disturbances, abnormally large pitch attitude response for a given pilot input at low speeds, and an initial delay in normal-acceleration response to pilot control at all flight conditions. The adaptive system chatter of +/-0.05 to +/-0.10 of elevon at about 9 cycles per second (resulting in a maximum airplane normal-acceleration response of from +/-0.025 g to +/- 0.035 g) was considered by the pilots to be mildly objectionable but tolerable.

McNeill, Water E.↗

Method and Apparatus for Characterizing Pressure Sensors using Modulated Light Beam Pressure

Embodiments of apparatuses and methods are provided that use light sources instead of sound sources for characterizing and calibrating sensors for measuring small pressures to mitigate many of the problems with using sound sources. In one embodiment an apparatus has a light source for directing a beam of light on a sensing surface of a pressure sensor for exerting a force on the sensing surface. The pressure sensor generates an electrical signal indicative of the force exerted on the sensing surface. A modulator modulates the beam of light. A signal processor is electrically coupled to the pressure sensor for receiving the electrical signal.

Robert C Youngquist↗

Separation of circadian and wake duration-dependent modulation of EEG activation during wakefulness

The separate contribution of circadian rhythmicity and elapsed time awake on electroencephalographic (EEG) activity during wakefulness was assessed. Seven men lived in an environmental scheduling facility for 4 weeks and completed fourteen 42.85-h 'days', each consisting of an extended (28.57-h) wake episode and a 14.28-h sleep opportunity. The circadian rhythm of plasma melatonin desynchronized from the 42.85-h day. This allowed quantification of the separate contribution of circadian phase and elapsed time awake to variation in EEG power spectra (1-32 Hz). EEG activity during standardized behavioral conditions was markedly affected by both circadian phase and elapsed time awake in an EEG frequency- and derivation-specific manner. The nadir of the circadian rhythm in alpha (8-12 Hz) activity in both fronto-central and occipito-parietal derivations occurred during the biological night, close to the crest of the melatonin rhythm. The nadir of the circadian rhythm of theta (4.5-8 Hz) and beta (20-32 Hz) activity in the fronto-central derivation was located close to the onset of melatonin secretion, i.e. during the wake maintenance zone. As time awake progressed, delta frequency (1-4.5 Hz) and beta (20-32 Hz) activity rose monotonically in frontal derivations. The interaction between the circadian and wake-dependent increase in frontal delta was such that the intrusion of delta was minimal when sustained wakefulness coincided with the biological day, but pronounced during the biological night. Our data imply that the circadian pacemaker facilitates frontal EEG activation during the wake maintenance zone, by generating an arousal signal that prevents the intrusion of low-frequency EEG components, the propensity for which increases progressively during wakefulness.

Non-NASA Center↗

Root gravitropism: a complex response to a simple stimulus?

Roots avoid depleting their immediate environment of essential nutrients by continuous growth. Root growth is directed by environmental cues, including gravity. Gravity sensing occurs mainly in the columella cells of the root cap. Upon reorientation within the gravity field, the root-cap amyloplasts sediment, generating a physiological signal that promotes the development of a curvature at the root elongation zones. Recent molecular genetic studies in Arabidopsis have allowed the identification of genes that play important roles in root gravitropism. Among them, the ARG1 gene encodes a DnaJ-like protein involved in gravity signal transduction, whereas the AUX1 and AGR1 genes encode proteins involved in polar auxin transport. These studies have important implications for understanding the intra- and inter-cellular signaling processes that underlie root gravitropism.

Review, Tutorial↗

Modelling protein functional domains in signal transduction using Maude

Modelling of protein-protein interactions in signal transduction is receiving increased attention in computational biology. This paper describes recent research in the application of Maude, a symbolic language founded on rewriting logic, to the modelling of functional domains within signalling proteins. Protein functional domains (PFDs) are a critical focus of modern signal transduction research. In general, Maude models can simulate biological signalling networks and produce specific testable hypotheses at various levels of abstraction. Developing symbolic models of signalling proteins containing functional domains is important because of the potential to generate analyses of complex signalling networks based on structure-function relationships.

Signal Transduction↗

Multifrequency Ultra-High Resolution Miniature Scanning Microscope Using Microchannel And Solid-State Sensor Technologies And Method For Scanning Samples

A miniature, ultra-high resolution, and color scanning microscope using microchannel and solid-state technology that does not require focus adjustment. One embodiment includes a source of collimated radiant energy for illuminating a sample, a plurality of narrow angle filters comprising a microchannel structure to permit the passage of only unscattered radiant energy through the microchannels with some portion of the radiant energy entering the microchannels from the sample, a solid-state sensor array attached to the microchannel structure, the microchannels being aligned with an element of the solid-state sensor array, that portion of the radiant energy entering the microchannels parallel to the microchannel walls travels to the sensor element generating an electrical signal from which an image is reconstructed by an external device, and a moving element for movement of the microchannel structure relative to the sample. Discloses a method for scanning samples whereby the sensor array elements trace parallel paths that are arbitrarily close to the parallel paths traced by other elements of the array.

Wang, Yu↗

Global Ionospheric Perturbations Monitored by the Worldwide GPS Network

Based on the delays of these (Global Positioning System-GPS)signals, we have generated high resolution global ionospheric TEC (Total Electronic Changes) maps at 15-minute intervals. Using a differential method comparing storm time maps with quiet time maps, we find that the ionopshere during this time storm has increased significantly (the percentage change relative to quiet times is greater than 150 percent) ...These preliminary results (those mentioned above plus other in the paper)indicate that the differential maping method, which is based on GPS network measurements appears to be a useful tool for studying the global pattern and evolution process of the entire ionospheric perturbation.

Global Positioning System GPS TEC Total Electronic↗

Global Ionosphere Perturbations Monitored by the Worldwide GPS Network

For the first time, measurements from the Global Positioning System (GPS) worldwide network are employed to study the global ionospheric total electron content(TEC) changes during a magnetic storm (November 26, 1994). These measurements are obtained from more than 60 world-wide GPS stations which continuously receive dual-frequency signals. Based on the delays of the signals, we have generated high resolution global ionospheric maps (GIM) of TEC at 15 minute intervals. Using a differential method comparing storm time maps with quiet time maps, we find that significant TEC increases (the positive effect ) are the major feature in the winter hemisphere during this storm (the maximum percent change relative to quiet times is about 150 percent).

GPS global positioning system TEC total electron c↗

MEMS Based Acoustic Array

Embodiments of the present invention described and shown in the specification aid drawings include a combination responsive to an acoustic wave that can be utilized as a dynamic pressure sensor. In one embodiment of the present invention, the combination has a substrate having a first surface and an opposite second surface, a microphone positioned on the first surface of the substrate and having an input and a first output and a second output, wherein the input receives a biased voltage, and the microphone generates an output signal responsive to the acoustic wave between the first output and the second output. The combination further has an amplifier positioned on the first surface of the substrate and having a first input and a second input and an output, wherein the first input of the amplifier is electrically coupled to the first output of the microphone and the second input of the amplifier is electrically coupled to the second output of the microphone for receiving the output sinual from the microphone. The amplifier is spaced from the microphone with a separation smaller than 0.5 mm.

Sheplak, Mark↗

New Help for the Sightless

Duke Lumsden operates a candy shop in Tacoma, Wash. Duke is blind, yet he has no trouble differentiating between the values of currency he handles in the course of business. He is aided by a spinoff from space-developed optical-electronic scanning technology known as the Paper Money Identifier. The PMI is manufactured by EMR Ltd., Los Angeles. It's not distinguishable by the human eye, but each denomination of American currency has a unique distribution of colors. This fact enables the PMI to tell the difference between different denominations of paper money. The device, the size of a cigarette pack, emits a narrow beam of invisible infrared light. This beam reacts to the reflectivity of the colors on the bill and causes an oscillator to generate an audible signal. As Duke passes his PMI lengthwise along the back of a bill, he hears a distinctive series of tones that identifies each denomination. Duke Lumsden is very pleased with the paper money identifier, which he got through Tacoma's Technology Transfer Center. He not only handles paper money with ease, but he has discovered another use for the device. Before receiving the PMI, he had difficulty operating his tape recorder because he couldn't determine which track the tape was using; now his PMI tells him, by reacting to the different colors on the switch button light.

Source record↗

Chemometric analysis for extraction of individual fluorescence spectrum and lifetimes from a target mixture

The present invention is a system for chemometric analysis for the extraction of the individual component fluorescence spectra and fluorescence lifetimes from a target mixture. The present invention combines a processor with an apparatus for generating an excitation signal to transmit at a target mixture and an apparatus for detecting the emitted signal from the target mixture. The present invention extracts the individual fluorescence spectrum and fluorescence lifetime measurements from the frequency and wavelength data acquired from the emitted signal. The present invention uses an iterative solution that first requires the initialization of several decision variables and the initial approximation determinations of intermediate matrices. The iterative solution compares the decision variables for convergence to see if further approximation determinations are necessary. If the solution converges, the present invention then determines the reduced best fit error for the analysis of the individual fluorescence lifetime and the fluorescence spectrum before extracting the individual fluorescence lifetime and fluorescence spectrum from the emitted signal of the target mixture.

Hallidy, William H.↗

Radial displacement sensor for non-contact bearings

A radial position sensor includes four capacitive electrodes oriented about a shaft, arranged in two diametrically opposite pairs. Sensor circuitry generates an output signal in proportion to the capacitance between the electrodes and the shaft; the capacitance between an electrode and the shaft increases as the shaft approaches the electrode and decreases as the shaft recedes from the electrode. The sensor circuitry applies an alternating voltage to one electrode of a pair and a 180 degree out of phase alternating voltage to the other electrode of the pair. The electrical responses of the two electrodes to their respective input signals are summed to form a radial deviation signal which is relatively free from the alternating voltage and accurately represents the position of the shaft relative to the electrodes of the pair.

McCormick, John A.↗