Search NASA⌕ Search

SEARCH · Search NASA

Results for “Standard Problem”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Linear and non-linear perturbations in dark energy models

In this work we discuss observational aspects of three time-dependent parameterisations of the dark energy equation of state w ( z ). In order to determine the dynamics associated with these models, we calculate their background evolution and perturbations in a scalar field representation. After performing a complete treatment of linear perturbations, we also show that the non-linear contribution of the selected w ( z ) parameterisations to the matter power spectra is almost the same for all scales, with no significant difference from the predictions of the standard ΛCDM model.

79 ASTRONOMY AND ASTROPHYSICS↗

Utilizing Adjoint-Based Error Estimates for Surrogate Models to Accurately Predict Probabilities of Events

In thist study, we develop a procedure to utilize error estimates for samples of a surrogate model to compute robust upper and lower bounds on estimates of probabilities of events. We show that these error estimates can also be used in an adaptive algorithm to simultaneously reduce the computational cost and increase the accuracy in estimating probabilities of events using computationally expensive high-fidelity models. Specifically, we introduce the notion of reliability of a sample of a surrogate model, and we prove that utilizing the surrogate model for the reliable samples and the high-fidelity model for the unreliable samples gives precisely the same estimate of the probability of the output event as would be obtained by evaluation of the original model for each sample. The adaptive algorithm uses the additional evaluations of the high-fidelity model for the unreliable samples to locally improve the surrogate model near the limit state, which significantly reduces the number of high-fidelity model evaluations as the limit state is resolved. Numerical results based on a recently developed adjoint-based approach for estimating the error in samples of a surrogate are provided to demonstrate (1) the robustness of the bounds on the probability of an event, and (2) that the adaptive enhancement algorithm provides a more accurate estimate of the probability of the QoI event than standard response surface approximation methods at a lower computational cost.

97 MATHEMATICS AND COMPUTING↗

Modern sensitivity analysis - 15651

Sensitivity analysis has been applied to complex models, such as performance assessment models, since at least the advent of computational tools to support such an approach to model evaluation. Initially, sensitivity analysis methods were applied to deterministic models and focused on changing one input variable at a time. Probabilistic modeling opened the door to evaluating changes in all input variables simultaneously. Standardized rank regression methods were primarily used in the last century to evaluate probabilistic models. These methods assume linearity in the rank response of the model to the inputs. At the very least this assumes monotonicity in the response, but for the most part the response needs to be near-linear. This is highly unlikely for performance assessment models that are based on differential equations, multiplication and division of variables that are usually not correlated, and conservatism that is not well understood. There are better statistical methods for evaluating highly non-linear and dynamic probabilistic models. Some of these methods were founded in the data mining industry. This century has seen a rapid development of the internet that led directly to the development of data mining techniques for massive databases. Although the goals were different, these techniques can be adapted to sensitivity analysis for complex probabilistic models, which, also, form large, or even massive, databases. These modern sensitivity analysis procedures assess the importance of every explanatory variable (input parameters) used in a probabilistic model. In practice, this means that for each endpoint of interest, every explanatory variable in the model is associated with a quantitative measure of importance. For a given explanatory variable, the importance value depends on the endpoint of interest. This global approach to sensitivity analysis allows all levels of interactions to be evaluated, so that the variation in the output can be measured at every level of possible interaction. The effects are collected together during sensitivity analysis processing, and then separated out to attribute the overall contribution of each input parameter to the model output. These global sensitivity analysis procedures have the ability to characterize non-linear and non-monotonic relationships between explanatory variables and endpoints of interest. This is critically important because of the need to characterize complex interactions among multiple explanatory variables in PA models that often have non-linear and non-monotonic effects. The options for sensitivity analysis are fully explored, including an evaluation of several methods when applying them to a well-known complex non-linear non-monotonic model. The results clearly demonstrate the relative benefit of using data mining methods over simple statistical approaches such as standardized rank regression. (authors)

97 MATHEMATICS AND COMPUTING↗

Cumulant methods for electron-phonon problems. II. The self-consistent cumulant expansion

Here in this paper we present a self-consistent cumulant expansion (SC-CE) and investigate its accuracy for the one-dimensional Holstein model with and without phonon dispersion. We show that for finite lattice sizes, the numerical integration of the SC-CE equations becomes unstable at long times. This defect is partially ameliorated when studying systems in the thermodynamic limit, enabling the demonstration that the SC-CE corrects many deficits of the standard perturbative CE in the (nondispersive) Holstein model. The natural phonon damping that arises in the more realistic dispersed Holstein model renders the SC-CE stable, allowing for a complete assessment of the method. Here, we find that self-consistency dramatically corrects many of the failures found in the perturbative CE, but also introduces some unphysical features. Finally, we comment on the potential use of SC-CE as a tool for calculating Green's functions in generic many-body problems.

36 MATERIALS SCIENCE↗

Evidence for the multiverse in the standard model and beyond

In any theory it is unnatural if the observed values of parameters lie very close to special values that determine the existence of complex structures necessary for observers. A naturalness probability P is introduced to numerically evaluate the degree of unnaturalness. If P is very small in all known theories, corresponding to a high degree of fine-tuning, then there is an observer naturalness problem. In addition to the well-known case of the cosmological constant, we argue that nuclear stability and electroweak symmetry breaking represent significant observer naturalness problems. The naturalness probability associated with nuclear stability depends on the theory of flavor, but for all known theories is conservatively estimated as P{sub nuc} < or approx. (10{sup -3}-10{sup -2}), and for simple theories of electroweak symmetry breaking P{sub EWSB} < or approx. (10{sup -2}-10{sup -1}). This pattern of unnaturalness in three different arenas, cosmology, nuclear physics, and electroweak symmetry breaking, provides evidence for the multiverse, since each problem may be easily solved by environmental selection. In the nuclear case the problem is largely solved even if the multiverse distribution for the relevant parameters is relatively flat. With somewhat strongly varying distributions, it is possible to understand both the close proximity to neutron stability and the values of m{sub e} and m{sub d}-m{sub u} in terms of the electromagnetic mass difference between the proton and neutron, {delta}{sub EM}{approx_equal}1{+-}0.5 MeV. It is reasonable that multiverse distributions are strong functions of Lagrangian parameters, since they depend not only on the landscape of vacua, but also on the population mechanism, ''integrating out'' other parameters, and on a density of observers factor. In any theory with mass scale M that is the origin of electroweak symmetry breaking, strongly varying multiverse distributions typically lead either to a little hierarchy v/M{approx_equal}(10{sup -2}-10{sup -1}), or to a large hierarchy v<<M. In certain multiverses, where electroweak symmetry breaking occurs only if M is below some critical value, we find that a little hierarchy develops with the value of v{sup 2}/M{sup 2} suppressed by an extra loop factor, as well as by the strength of the distribution. Since the correct theory of electroweak symmetry breaking is unknown, our estimate for P{sub EWSB} is theoretical. The LHC will lead to a much more robust determination of P{sub EWSB}, and, depending on which theory is indicated by the data, the observer naturalness problem of electroweak symmetry breaking may be removed or strengthened. For each of the three arenas, the discovery of a natural theory would eliminate the evidence for the multiverse; but in the absence of such a theory, the multiverse provides a provisional understanding of the data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sequential ensemble transform for Bayesian inverse problems

In this work, we present the Sequential Ensemble Transform (SET) method, an approach for generating approximate samples from a Bayesian posterior distribution. The method explores the posterior distribution by solving a sequence of discrete optimal transport problems to produce a series of transport plans which map prior samples to posterior samples. We prove that the sequence of Dirac mixture distributions produced by the SET method converges weakly to the true posterior as the sample size approaches infinity. Furthermore, our numerical results indicate that, when compared to standard Sequential Monte Carlo (SMC) methods, the SET approach is more robust to the choice of Markov mutation kernels and requires less computational efforts to reach a similar accuracy when used to explore complex posterior distributions. Finally, we describe adaptive schemes that allow to completely automate the use of the SET method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A robust and efficient finite volume method for compressible inviscid and viscous two-phase flows [A robust and efficient finite volume method for compressible viscous two-phase flows]

A robust and efficient density-based finite volume method is developed for solving the six-equation single pressure system of two-phase flows at all speeds on hybrid unstructured grids. Unlike conventional approaches where an expensive exact Riemann solver is normally required for computing numerical fluxes at the two-phase interfaces in addition to AUSM-type fluxes for single-phase interfaces in order to maintain stability and robustness in cases involving interactions of strong pressure and void-fraction discontinuities, a volume-fraction coupling term for the AUSM + -up fluxes is introduced in this work to impart the required robustness without the need of the exact Riemann solver. The resulting method is significantly less expensive in regions where otherwise the Riemann solver would be invoked. A transformation from conservative variables to primitive variables is presented and the primitive variables are then solved in the implicit method in order for the current finite volume method to be able to solve, effectively and efficiently, low Mach number flows in traditional multiphase applications, which otherwise is a great challenge for the standard density-based algorithms. Here, a number of benchmark test cases are presented to assess the performance and robustness of the developed finite volume method for both inviscid and viscous two-phase flow problems. The numerical results indicate that the current density-based method provides an attractive and viable alternative to its pressure-based counterpart for compressible two-phase flows at all speeds.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

2D grating simulation for X-ray phase-contrast and dark-field imaging with a Talbot interferometer

Talbot interferometry is a recently developed and an extremely powerful X-ray phase-contrast imaging technique. Besides giving access to ultra-high sensitivity differential phase contrast images, it also provides the dark field image, which is a map of the scattering power of the sample. In this paper we investigate the potentialities of an improved version of the interferometer, in which two dimensional gratings are used instead of standard line grids. This approach allows to overcome the difficulties that might be encountered in the images produced by a one dimensional interferometer. Among these limitations there are the phase wrapping and quantitative phase retrieval problems and the directionality of the differential phase and dark-field signals. The feasibility of the 2D Talbot interferometer has been studied with a numerical simulation on the performances of its optical components under different circumstances. The gratings can be obtained either by an ad hoc fabrication of the 2D structures or by a superposition of two perpendicular linear grids. Through this simulation it has been possible to find the best parameters for a practical implementation of the 2D Talbot interferometer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Bayesian calibration of coarse-grained forces: Efficiently addressing transferability

Generating and calibrating forces that are transferable across a range of state-points remains a challenging task in coarse-grained (CG) molecular dynamics. In this work, we present a coarse-graining workflow, inspired by ideas from uncertainty quantification and numerical analysis, to address this problem. The key idea behind our approach is to introduce a Bayesian correction algorithm that uses functional derivatives of CG simulations to rapidly and inexpensively recalibrate initial estimates f{sub 0} of forces anchored by standard methods such as force-matching. Taking density-temperature relationships as a running example, we demonstrate that this algorithm, in concert with various interpolation schemes, can be used to efficiently compute physically reasonable force curves on a fine grid of state-points. Importantly, we show that our workflow is robust to several choices available to the modeler, including the interpolation schemes and tools used to construct f{sub 0}. In a related vein, we also demonstrate that our approach can speed up coarse-graining by reducing the number of atomistic simulations needed as inputs to standard methods for generating CG forces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The cosmological backreaction: gauge (in)dependence, observers and scalars

We discuss several issues related to a recent proposal for defining classical spatial averages to be used in the so-called cosmological backreaction problem. In the large averaging-volume limit all gauge dependence disappears and different averages can be univocally characterized by the observers associated with different scalar fields. The relation between such averaging procedure and the standard one is emphasized and a gauge invariant way to select different observers is presented. For finite averaging volumes we show that, within our proposal, a residual gauge dependence is left, but is suppressed by several effects.

79 ASTRONOMY AND ASTROPHYSICS↗

Coupled Boltzmann computation of mixed axion neutralino dark matter in the SUSY DFSZ axion model

The supersymmetrized DFSZ axion model is highly motivated not only because it offers solutions to both the gauge hierarchy and strong CP problems, but also because it provides a solution to the SUSY μ-problem which naturally allows for a Little Hierarchy. We compute the expected mixed axion-neutralino dark matter abundance for the SUSY DFSZ axion model in two benchmark cases—a natural SUSY model with a standard neutralino underabundance (SUA) and an mSUGRA/CMSSM model with a standard overabundance (SOA). Our computation implements coupled Boltzmann equations which track the radiation density along with neutralino, axion, axion CO (produced via coherent oscillations), saxion, saxion CO, axino and gravitino densities. In the SUSY DFSZ model, axions, axinos and saxions go through the process of freeze-in—in contrast to freeze-out or out-of-equilibrium production as in the SUSY KSVZ model—resulting in thermal yields which are largely independent of the re-heat temperature. We find the SUA case with suppressed saxion-axion couplings (ξ=0) only admits solutions for PQ breaking scale f{sub a}∼< 6× 10{sup 12} GeV where the bulk of parameter space tends to be axion-dominated. For SUA with allowed saxion-axion couplings (ξ =1), then f{sub a} values up to ∼ 10{sup 14} GeV are allowed. For the SOA case, almost all of SUSY DFSZ parameter space is disallowed by a combination of overproduction of dark matter, overproduction of dark radiation or violation of BBN constraints. An exception occurs at very large f{sub a}∼ 10{sup 15}–10{sup 16} GeV where large entropy dilution from CO-produced saxions leads to allowed models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Newton constant and gravitational waves in some vector field adjusting mechanisms

At the present, there exist some Lorentz breaking scenarios which explain the smallness of the cosmological constant at the present era [1]–[2]. An important aspect to analyze is the propagation of gravitational waves and the screening or enhancement of the Newton constant G {sub N} in these models. The problem is that the Lorentz symmetry breaking terms may induce an unacceptable value of the Newton constant G {sub N} or introduce longitudinal modes in the gravitational wave propagation. Furthermore this breaking may spoil the standard dispersion relation ω= ck . In [3] the authors have presented a model suggesting that the behavior of the gravitational constant is correct for asymptotic times. In the present work, an explicit checking is made and we finally agree with these claims. Furthermore, it is suggested that the gravitational waves are also well behaved for large times. In the process, some new models with the same behavior are obtained, thus enlarging the list of possible adjustment mechanisms.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Unified origin of inflation, baryon asymmetry, and neutrino mass

In this work, we present a unified theoretical framework that simultaneously addresses some of the most intriguing puzzles in particle physics and cosmology, namely the origins of neutrino mass, baryon asymmetry, and cosmic inflation. In our model, inflation is driven by a combination of the Standard Model Higgs, the type II seesaw Higgs responsible for neutrino mass generation, and the unified symmetry-breaking Higgs field. During inflation, nonzero values of the latter field ensure the absence of the monopole problem. The baryon asymmetry is generated through the Affleck-Dine mechanism, facilitated by the nonzero angular motion in the phase of a complex scalar field, which is part of the inflaton. We find that the successful parameter region for generating baryon asymmetry through a renormalizable term in the scalar potential requires a rather heavy type II seesaw triplet, with a mass well beyond the TeV scale. Inflationary observables, in particular, the spectral index is in excellent agree with experimental observation, whereas tensor-to scalar ratio is expected to be probed by the future LiteBIRD and CMB-S4 missions. Published by the American Physical Society 2024

Kaladharan, Ajay (ORCID:0000000165096427)↗

A Precision, Low-Cost GPS-Based Transmitter Synchronization Scheme for Improved AM Reception

This paper describes a highly accurate carrier-frequency synchronization scheme for actively, automatically locking multiple, remotely located AM broadcast transmitters to a common frequency/timing reference source such as GPS. The extremely tight frequency lock (to {approx}1 part in 10{sup 9} or better) permits the effective elimination of audible and even sub-audible beats between the local (desired) station's carrier signal and the distant stations carriers, usually received via skywave propagation during the evening and nighttime hours. These carrier-beat components cause annoying modulations of the desired station's audio at the receiver and concurrent distortion of the audio modulation from the distant station(s) and often cause listeners to ldquotune outrdquo due to the low reception quality. Significant reduction or elimination of the beats and related effects will greatly enlarge the effective (interference-limited) listening area of the desired station (from 4 to 10 times as indicated in our tests) and simultaneously reduce the corresponding interference of the local transmitter to the distant stations as well. In addition, AM stereo (CQUAM) reception will be particularly improved by minimizing the phase shifts induced by co-channel interfering signals; hybrid digital (HD) signals will also benefit via reduction in beats from analog signals. The automatic frequency-control hardware described is inexpensive ($1000-$2000), requires no periodic recalibration, has essentially zero long-term drift, and could employ alternate wide-area frequency references of suitable accuracy, including broadcasts from WWVB, LORAN-C, and equivalent sources. The basic configuration of the GPS-disciplined oscillator which solves this problem is extremely simple. The main oscillator is a conventional high-stability quartz-crystal type. To counter long- term drifts, the oscillator is slightly adjusted to track a high-precision source of standard frequency obtained from a specialized GPS receiver (or other source), usually at 10.000 MHz. This very stable local reference frequency is then used as a clock for a standard digitally implemented frequency synthesizer, which is programmed to generate the specific carrier frequency desired. The stability of the disciplining source, typically {approx}1 part in 10{sup 9} to 10{sup 11}, is thus transferred to the final AM transmitter carrier output frequency.

42 ENGINEERING↗

SU-F-19A-11: Retrospective Evaluation of Thermal Coverage by Thermobrachytherapy Seed Arrangements of Clinical LDR Prostate Implants

Purpose: The superiority of a properly-administered combination of radiation therapy and hyperthermia over radiation alone in treatment of human cancers has been demonstrated in multiple studies examining radiobiology, local control, and survival. Unfortunately, hyperthermia is not yet a common modality in oncology practice, due in part to the technical difficulty of heating a deep-seated target volume to sufficient temperature. To address this problem, our group has invented a thermobrachytherapy (TB) seed based on a commonly-used low dose-rate permanent brachytherapy seed for implant in solid tumors. Instead of the tungsten radiographic marker of the standard seed, the TB seed contains one of a self-regulating ferromagnetic alloy. Placement of a patient implanted with such seeds in an oscillating magnetic field generates heat via induction of eddy currents. We present the results of studies of the capability of clinically-realistic TB seed arrangements to adequately heat defined target volumes. Methods: Seed distributions for several past LDR prostate permanent implant brachytherapy patients were reproduced in the finite element analysis software package COMSOL Multiphysics 4.4, with the difference that TB seeds were modelled, rather than the radiation-only seeds actually used for their treatments. The implant geometries were mainly of the modified peripheral loading type; a range of prostatic volumes and blood perfusion rates likely to be seen in a clinical setting were examined. Results: According to the simulations, when distributed to optimize radiation dose, TB seeds also produce sufficient heat to provide thermal coverage of the target given proper selection of the magnetic field strength. However, the thermal distributions may be improved by additional use of hyperthermia-only seeds. Conclusion: A dual-modality seed intended as an alternative to and using the same implantation apparatus and technique as the standard LDR permanent implant seed has been successfully evaluated for its ability to provide sufficient hyperthermia in clinically-realistic implants. This work was partially supported by the National Institutes of Health (NIH) STTR Grant No. R41 CA153631-01A1.

60 APPLIED LIFE SCIENCES↗

TH-E-209-00: Radiation Dose Monitoring and Protocol Management

Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilities over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.

60 APPLIED LIFE SCIENCES↗

TH-E-209-01: Fluoroscopic Dose Monitoring and Patient Follow-Up Program at Massachusetts General Hospital

Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilities over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.

60 APPLIED LIFE SCIENCES↗

TH-E-209-02: Dose Monitoring and Protocol Optimization: The Pediatric Perspective

Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilities over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.

60 APPLIED LIFE SCIENCES↗