Search NASA⌕ Search

SEARCH · Search NASA

Results for “System Study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Poster — Thur Eve — 19: Performance assessment of a 160-leaf beam collimation system

In this study, the performance of the new beam collimation system with 160 leaves, each with a 5 mm leaf width projected at isocenter, is evaluated in terms of positional accuracy and plan/delivery quality. Positional accuracy was evaluated using a set of static and dynamic MLC/jaw delivery patterns at different gantry angles, dose rates, and MLC/jaw speeds. The impact on IMRT plan quality was assessed by comparing against a previous generation collimation system using the same optimization parameters, while delivery quality was quantified using a combination of patient-specific QA measurements with ion chambers, film, and a bi-planar diode array. Positional accuracy for four separate units was comparable. The field size accuracy, junction width, and total displacement over 16 cm leaf travel are 0.3 ± 0.2 mm, 0.4 ± 0.3 mm, and 0.5 ± 0.2 mm, respectively. The typical leaf minor offset is 0.05 ± 0.04 mm, and MLC hysteresis effects are 0.2 ± 0.1 mm over 16 cm travel. The dynamic output is linear with MU and MLC/jaw speed, and is within 0.7 ± 0.3 % of the planning system value. Plan quality is significantly improved both in terms of target coverage and OAR sparing due, in part, to the larger allowable MLC and jaw speeds. γ-index pass rates for the patient-specific QA measurements exceeded 97% using criteria of 2%/2 mm. In conclusion, the performance of the Agility system is consistent among four separate installations, and is superior to its previous generations of collimation systems.

07 ISOTOPE AND RADIATION SOURCES↗

Properly Understanding the Impacts of Distributed Resources on Distribution Systems

The subject paper discusses important impacts of distributed resources on distribution networks and feeders. These include capacity, line losses, voltage regulation, and central system support (such as volt/var via central generators and substation) as the number, placement and penetration levels of distributed resources are varied. Typically, the impacts of distributed resources on the distribution system are studied by using steady-state rather than dynamic analysis tools. However, the response time and transient impacts of both system equipment (such as substation/feeder capacitors) and distributed resources needs to be taken into account and only dynamic analysis will provide the full impact results. ORNL is wrapping up a study of distributed resources interconnected to a large distribution system considering the above variables. A report of the study and its results will be condensed into a paper for this panel session. The impact of distributed resources will vary as the penetration level reaches the capacity of the distribution feeder/system. The question is how high of a penetration of distributed resource can be accommodated on the distribution feeder/system without any major changes to system operation, design and protection. The impacts most surely will vary depending upon load composition, distribution and level. Also, it is expected that various placement of distributed resources will impact the distribution system differently.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Capacity Utilization Study for Aviation Security Cargo Inspection Queuing System

In this paper, we conduct performance evaluation study for an aviation security cargo inspection queuing system for material flow and accountability. The queuing model employed in our study is based on discrete-event simulation and processes various types of cargo simultaneously. Onsite measurements are collected in an airport facility to validate the queuing model. The overall performance of the aviation security cargo inspection system is computed, analyzed, and optimized for the different system dynamics. Various performance measures are considered such as system capacity, residual capacity, throughput, capacity utilization, subscribed capacity utilization, resources capacity utilization, subscribed resources capacity utilization, and number of cargo pieces (or pallets) in the different queues. These metrics are performance indicators of the system s ability to service current needs and response capacity to additional requests. We studied and analyzed different scenarios by changing various model parameters such as number of pieces per pallet, number of TSA inspectors and ATS personnel, number of forklifts, number of explosives trace detection (ETD) and explosives detection system (EDS) inspection machines, inspection modality distribution, alarm rate, and cargo closeout time. The increased physical understanding resulting from execution of the queuing model utilizing these vetted performance measures should reduce the overall cost and shipping delays associated with new inspection requirements.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Tolerance Studies of the Mu2e Solenoid System

The muon-to-electron conversion experiment at Fermilab is designed to explore charged lepton flavor violation. It is composed of three large superconducting solenoids, namely, the production solenoid, the transport solenoid, and the detector solenoid. Each subsystem has a set of field requirements. Tolerance sensitivity studies of the magnet system were performed with the objective of demonstrating that the present magnet design meets all the field requirements. Systematic and random errors were considered on the position and alignment of the coils. The study helps to identify the critical sources of errors and which are translated to coil manufacturing and mechanical support tolerances.

43 PARTICLE ACCELERATORS↗

Energy, economic, and environmental analysis of integration of thermal energy storage into district heating systems using waste heat from data centres

Data centres produce waste heat, which can be utilized in district heating systems. However, the mismatch between data centres’ heat supply and district heating systems’ heat demands limits its utilization. Further, high peak loads increase the operation cost of district heating systems. This study aimed to solve these problems by introducing thermal energy storages. A water tank and a borehole thermal energy storage system were selected as the short-term and long-term thermal energy storage, respectively. Energy, economic, and environmental indicators were introduced to evaluate different solutions. The case study was a campus district heating system in Norway. Results showed that the water tank could shave the peak load by 31% and save the annual energy cost by 5%. The payback period was lower than 15 years when the storage efficiency remained higher than 80%. However, it had no obvious benefits in terms of mismatch relieving and CO emissions reduction. In contrast, the borehole thermal energy storage increased the waste heat utilization rate to 96% and reduced the annual CO emissions by 8%. However, the payback period was more than 17 years. These results provide guidelines for the retrofit of district heating systems, where data centres’ waste heat is available.

25 ENERGY STORAGE↗

Vascular smooth cell proliferation in perfusion culture of porcine carotid arteries

Objective of this study was to develop a novel in vitro artery culture system to study vascular smooth muscle cell (SMC) proliferation of porcine carotid arteries in response to injury, basic fibroblast growth factor (FGF2), and FGF2 conjugated with cytotoxin saporin (SAP). Perfusion-cultured porcine carotid arteries remained contractile in response to norepinephrine and relaxant to acetylcholine for up to 96 h. SMC proliferation of cultured arteries was detected by bromodeoxyuridine incorporation in both non-injured and balloon-injured arteries. In the inner layer of the vessel wall near the lumen, SMC proliferation were less than 10% in uninjured vessels, 66% in injured vessels, 80% in injured vessels with FGF2 treatment, and 5% in injured vessels with treatment of FGF2-SAP. Thus, the cultured porcine carotid arteries were viable; and the injury stimulated SMC proliferation, which was significantly enhanced by FGF2 and inhibited by FGF2-SAP.

60 APPLIED LIFE SCIENCES↗

Structural ordering at solid-liquid interfaces in Al-Sm system: A molecular-dynamics study

The structural ordering at solid-liquid interfaces far from equilibrium is studied with molecular dynamics simulations for the Al-Sm system. Using the van-Hove self-correlation function as the criterion to identify attachment/detachment events that occur at the interface, we are able to determine the time-dependent interface position, and characterize the detailed interfacial structure ordering surrounding the attached atoms. For the interface between an undercooled Al90Sm10 liquid and a metastable cubic structure, the solid induces the crystalline order of the cubic phase in the liquid layers, promoting the continuous growth of the crystal phase. When the same liquid is put in contact with f.c.c. Al, Sm from the liquid can still attach to the solid interface despite its insolubility in the Al lattice. Non-f.c.c. order is revealed surrounding the attached Sm atoms. Lastly, we show that the local structure ordering at interface is highly correlated to solid packing and liquid ordering.

36 MATERIALS SCIENCE↗

Chemical Stabilization and Electrochemical Destabilization of the Iron Keggin Ion in Water

The iron Keggin ion is identified as a structural building block in both magnetite and ferrihydrite, two important iron oxide phases in nature and in technology. Discrete molecular forms of the iron Keggin ion that can be both manipulated in water and chemically converted to the related metal oxides are important for understanding growth mechanisms, in particular non-classical nucleation in which cluster building units are preserved in the aggregation and condensation processes. Here we describe two iron Keggin ion structures, formulated [Bi6FeO4Fe12O12(OH)12(CF3COO)10(H2O)2]3+ and [Bi6FeO4Fe12O12(OH)12(CF3COO)12]1+. Experimental and simulated X-ray scattering studies show indefinite stability of these clusters in water from pH 1-3. The tridecameric iron Keggin-ion core is protected from hydrolysis by a synergistic effect of the capping Bi3+-cations and the trifluoroacetate ligands that respectively bond to the iron and bridge to the bismuth. By introducing electrons to the aqueous solution of clusters, we achieve complete separation of bismuth from the cluster, and the iron Keggin ion rapidly converts to magnetite and/or ferrihydrite, depending on the mechanism of reduction. In this strategy, we take advantage of the easily accessible reduction potential and crystallization energy of bismuth. Reduction was executed in bulk by chemical means, by voltammetry, and by secondary effects of transmission electron microscopy imaging of solutions. Prior, we showed a less stable analogue of the iron Keggin cluster converted to ferrihydrite simply upon dissolution. The prior and currently studied clusters with a range of reactivity provide a chemical system to study molecular cluster metal oxide conversion processes in detail.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Strongly coupled dusty plasmas: finite and extended systems

Systems of confined microspheres in a gaseous plasma environment are studied. These systems of trapped 'dust' particles can form extended structures where the size of the system is much larger than interparticle distance. With specially tailored confinement potentials also finite arrangements of microspheres can be formed. In these systems the structure and dynamics dramatically depend on the exact particle number. Here, three-dimensional finite systems of microspheres, so-called Yukawa balls, are investigated and their structural properties are discussed with respect to the realized configurations of ground and metastable states.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Impacts of Distinct Flexibility Enhancements on the Value and Dynamics of Natural Gas Power Plant Operations

The rapid increase of renewable generation and its anticipated continued growth requires greater operational flexibility in modern power systems. Previous studies explored the addition of more flexible resources to improve system flexibility, but this may also be achieved at lower cost by enhancing existing power plants via flexibility retrofits. Potential flexibility upgrades to existing thermal plants include modifications that enable faster ramp rates, increase maximum load levels, decrease minimum load levels, and provide faster and lower cost startup operations. In this paper, we focus on improvements to existing natural gas combined cycle generators, and apply a unit commitment model to analyze the impact that each specific upgrade has on their operational dynamics and profitability from both the system perspective and from the asset owner perspective. We show that the value of each type of flexibility improvement varies depending on the capacity factor and usage pattern of the generator before the upgrade, and that the relative benefit of each type of flexibility varies. We demonstrate diminishing returns to increased flexibility when upgrading multiple generators simultaneously. Sensitivity tests for several shares of renewable generation, different generation mixes and different net load realizations confirm the generality of the results shown.

03 NATURAL GAS↗

Standardizing Performance Metrics for Building-Level Electrical Distribution Systems

Building-level electrical distribution systems comprise a myriad of current-carrying equipment, conversion devices, and protection devices that deliver power from the utility or local distributed energy resources to end-use building loads. Electric power has traditionally been generated, transmitted, and distributed in alternating current (AC). However, the last decade has seen a significant increase in the integration of native direct current (DC) equipment that has elevated the importance of DC distribution systems. Numerous studies have comparatively examined the performance of various electrical distribution systems in buildings but have failed to achieve uniform conclusions, primarily because of a lack of consistent and analogous performance evaluation methods. This paper aims to fill this gap by providing a standard set of metrics and measurement boundaries to consistently evaluate the performance of AC, DC, or hybrid AC/DC electrical distribution systems. The efficacy of the proposed approach is evaluated on a representative medium-sized commercial office building model with AC distribution and an equivalent hybrid AC/DC and DC distribution model, wherein the AC distribution model is concluded to be the most efficient. The simulation results show variation in computed metrics with different selected boundaries that verify the effectiveness of the proposed approach in ensuring consistent computation of the performance of building-level electrical distribution systems. This paper provides an initial set of guidelines for building energy system stakeholders to adopt appropriate solutions, thus leading to more efficient energy systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low‐Volume Cores for Fabrication of Compact, Versatile, and Intelligent Soft Systems

Abstract This study introduces the low‐volume core (LVC) fabrication method, which enables the monolithic molding of compact, complex, versatile, and intelligent soft robotic systems. This method uses thin and flexible thermoplastic sheets to mold internal chambers in soft fluidic actuators, valves, and circuits. The LVC fabrication method creates low‐volume networks in soft actuators (LV‐net actuators) that can be made with compact and complex geometries, enabling both low actuation volume input and multi‐degree‐of‐freedom actuators. LVC fabrication can also be used for compact, completely soft, and monolithic logic components (valves with low‐volume core, also called as LV valves) to provide directional resistance as well as a switching mechanism that enables fluidic logic in soft systems. The compatibility of the fabrication methods for both soft actuators and valves facilitates the creation of compact, integrated, and versatile soft robotic systems with embodied intelligence. This study introduces two examples of such intelligent soft robotic systems that integrate both LV‐net actuators and LV valves to demonstrate capability for complex system fabrication.

Yu, Qifan↗

CO2-Binding Organic Liquids Gas Capture with Polarity-Swing-Assisted Regeneration Full Technology Feasibility Study B1 - Solvent-based Systems

PNNL, Fluor Corporation and Queens University (Kingston, ON) successfully completed a three year comprehensive study of the CO2BOL water-lean solvent platform with Polarity Swing Assisted Regeneration (PSAR). This study encompassed solvent synthesis, characterization, environmental toxicology, physical, thermodynamic and kinetic property measurements, Aspen Plus™ modeling and bench-scale testing of a candidate CO2BOL solvent molecule. Key Program Findings The key program findings are summarized as follows: • PSAR favorably reduced stripper duties and reboiler temperatures with little/no impact to absorption column • >90% CO2 capture was achievable at reasonable liquid-gas ratios in the absorber • High rich solvent viscosities (up to 600 cP) were successfully demonstrated in the bench-scale system. However, the projected impacts of high viscosity to capital cost and operational limits compromised the other levelized cost of electricity benefits. • Low thermal conductivity of organics significantly increased the required cross exchanger surface area, and potentially other heat exchange surfaces. • CO2BOL had low evaporative losses during bench-scale testing • There was no evidence of foaming during bench scale testing • Current CO2BOL formulation costs project to be $35/kg • Ecotoxicity (Water Daphnia) was comparable between CO2BOL and MEA (169.47 versus 103.63 mg/L) • Full dehydration of the flue gas was determined to not be economically feasible. However, modest refrigeration (13 MW for the 550 MW reference system) was determined to be potentially economically feasible, and still produce a water-lean condition for the CO2BOLs (5 wt% steady-state water loading). • CO2BOLs testing with 5 wt% water loading did not compromise anhydrous performance behavior, and showed actual enhancement of CO2 capture performance. • Mass transfer of CO2BOLs was not greatly impeded by viscosity • Facile separation of antisolvent from lean CO2BOL was demonstrated on the bench cart • No measurable solvent degradation was observed over 4 months of testing – even with 5 wt% water present

Heldebrant, David J↗

Antiferromagnetic, metal-insulator, and superconducting phase transitions in underdoped cuprates: Slave-fermion t-J model in the hopping expansion

We study a system of doped antiferromagnet in three dimensions at finite temperatures using the t-J model, a canonical model of strongly correlated electrons. We employ the slave-fermion representation of electrons, in which an electron is described as a composite of a charged spinless holon and a chargeless spinon. We introduce two kinds of U(1) gauge fields on links as auxiliary fields, one describing resonating valence bonds of antiferromagnetic nearest-neighbor spin pairs and the other for nearest-neighbor hopping amplitudes of holons and spinons in the ferromagnetic channel. To perform a numerical study of the system, we integrate out the fermionic holon field by using the hopping expansion in powers of the hopping amplitude, which is legitimate for the region in and near the insulating phase. The resultant effective model is described in terms of bosonic spinons, two U(1) gauge fields, and a collective field for hole pairs. We study this model by means of Monte Carlo simulations, calculating the specific heat, spin correlation functions, and instanton densities. We obtain a phase diagram in the hole concentration-temperature plane, which is in good agreement with that observed recently for clean and homogeneous underdoped samples.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Role of Solvents on the Thermodynamics and Kinetics of Forming Frustrated Lewis Pairs

To enhance our understanding of the role of solvent on the thermodynamics and kinetics of forming Frustrated Lewis pairs (FLP), we carried out a systematic simulation study on these systems in dichloromethane and toluene solvents. These molecular systems are of particular interest due to their relevance in the catalytic hydrogenation and hydrogen storage processes. While the computed structural observables for both molecules are very similar, the slow molecular reorientation was consistent with the size of the species. The computed free energy profiles for the FLP in both solvents show similar gross characteristics but differ in details. We observe two well-defined contact and a solvent-separated regions with different well depths and barrier heights to dissociation. The kinetics of solute-pair interconversion was studied using transition state theory, comparing Kramers and Grote Hynes treatment of the dynamic response of the solvent. These rate results were used to predict solvent effects on dynamical features of contact solute-pair association. This work was supported by the US Department of Energy, Office of Basic Energy Sciences, Division of Chemical Sciences, Geosciences, and Biosciences. Pacific Northwest National Laboratory (PNNL) is a multiprogram national laboratory operated for DOE by Battelle. The calculations were carried out using computer resources provided by BES. Method development benefits M86304. The scientific understanding of the systems studied benefits F63768

Dang, Liem X↗

The Role of Concentrating Solar Power Toward High Renewable Energy Penetrated Power Systems

Achieving high renewable energy penetrated power systems requires considerable operational flexibility to hedge the variability and uncertainty of variable renewable energy (VRE) generation. Compared with VRE sources, concentrating solar power (CSP) is an emerging controllable renewable generation technique that utilizes solar thermal power to generate electricity. The operational dispatchability of CSP would contribute to the power system transition toward high renewable penetration. In this paper, we explore how the generation portfolio will change toward high renewable energy penetrations, how much cost is involved, and what role CSP will play in realizing a high renewable energy penetrated power system. This study relies on a stochastic two-stage generation and transmission expansion planning model with CSP plants. The model captures the uncertainty and variability of renewable generation and the flexibility limits of thermal plants. With the target of achieving a renewable-dominated minimum-cost system with an expected renewable energy penetration level, the investments of both generation and transmission facilities are optimized. A case study on IEEE test systems with renewable technology cost data in 2050 is performed to analyze the value of CSP toward high renewable energy penetrated power systems.

14 SOLAR ENERGY↗

Using occupant interaction with advanced lighting systems to understand opportunities for energy optimization: Control data from a hospital NICU

For this study, lighting system control data from five patient rooms in a neonatal intensive care unit (NICU) over a 25-week monitoring period were analyzed to better understand how the NICU staff and families interacted with an automatic tunable lighting system (variable spectrum and intensity) with manual override options. The data were analyzed to determine the amount of time spent in available lighting modes, estimate energy consumption, and to observe any patterns in how the lighting system was being used by occupants. Further analysis revealed opportunities for optimizing the system for occupant needs and energy savings. The patient room occupants were clearly engaged in using the lighting system throughout the 24-hour day to meet needs and preferences. Giving occupants control over the lighting system did not result in a considerable increase in energy use. Implementing a time-out would minimize the extended periods of time when the lights were left on without need at the highest brightness level, further decreasing energy use. This analysis reveals the potential of lighting control data to contribute to energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗