Search NASA⌕ Search

SEARCH · Search NASA

Results for “Testing Procedure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

ATLS-stowage and deployment testing of medical supplies and pharmaceuticals

The objective is to evaluate stowage and deployment methods for the Health Maintenance Facility (HMF) during microgravity. The specific objectives of this experiment are: (1) to evaluate the stowage and deployment mechanisms for the medical supplies; and (2) to evaluate the procedures for performing medical scenarios. To accomplish these objectives, the HMF test mini-racks will contain medical equipment mounted in the racks; and self-contained drawers with various mechanisms for stowing and deploying items. The medical supplies and pharmaceuticals will be destowed, handled, and restowed. The in-flight test procedures and other aspects of the KC-135 parabolic flight test to simulate weightlessness are presented.

Gosbee, John↗

Ten-Ecosystem Study

Remote sensing methodology developed for the Nationwide Forestry Applications Program utilize computer data processing procedures for performing inventories from satellite imagery. The Ten-Ecosystem Study (TES) was developed to test the processing procedures in an intermediate-sized application study. The results of TES indicate that LANDSAT multispectral imagery and associated automatic data processing techniques can be used to distinguish softwood, hardwood, grassland, and water and make inventory of these classes with an accuracy of 70 percent or better. The technical problems encountered during the TES and the solutions and insights to these problems are discussed. The TES experience is useful in planning subsequent inventories utilizing remote sensing technology.

Mazade, A. V.↗

Preparing GMAT for Operational Maneuver Planning of the Advanced Composition Explorer (ACE)

The General Mission Analysis Tool (GMAT) is an open-source space mission design, analysis and trajectory optimization tool. GMAT is developed by a team of NASA, private industry, public and private contributors. GMAT is designed to model, optimize and estimate spacecraft trajectories in flight regimes ranging from low Earth orbit to lunar applications, interplanetary trajectories and other deep space missions. GMAT has also been flight qualified to support operational maneuver planning for the Advanced Composition Explorer (ACE) mission. ACE was launched in August, 1997 and is orbiting the Sun-Earth L1 libration point. The primary science objective of ACE is to study the composition of both the solar wind and the galactic cosmic rays. Operational orbit determination, maneuver operations and product generation for ACE are conducted by NASA Goddard Space Flight Center (GSFC) Flight Dynamics Facility (FDF). This paper discusses the entire engineering lifecycle and major operational certification milestones that GMAT successfully completed to obtain operational certification for the ACE mission. Operational certification milestones such as gathering of the requirements for ACE operational maneuver planning, gap analysis, test plans and procedures development, system design, pre-shadow operations, training to FDF ACE maneuver planners, shadow operations, Test Readiness Review (TRR) and finally Operational Readiness Review (ORR) are discussed. These efforts have demonstrated that GMAT is flight quality software ready to support ACE mission operations in the FDF.

Trajectory analysis↗

Preparing General Mission Analysis Tool for Operational Maneuver Planning of the Advanced Composition Explorer Mission

The General Mission Analysis Tool (GMAT) is an open-source space mission design, analysis and trajectory optimization tool. GMAT is developed by a team of NASA, private industry, public and private contributors. GMAT is designed to model, optimize and estimate spacecraft trajectories in flight regimes ranging from low Earth orbit to lunar applications, interplanetary trajectories and other deep space missions. GMAT has also been flight qualified to support operational maneuver planning for the Advanced Composition Explorer (ACE) mission. ACE was launched in August, 1997 and is orbiting the Sun-Earth L1 libration point. The primary science objective of ACE is to study the composition of both the solar wind and the galactic cosmic rays. Operational orbit determination, maneuver operations and product generation for ACE are conducted by NASA Goddard Space Flight Center (GSFC) Flight Dynamics Facility (FDF). This paper discusses the entire engineering lifecycle and major operational certification milestones that GMAT successfully completed to obtain operational certification for the ACE mission. Operational certification milestones such as gathering of the requirements for ACE operational maneuver planning, gap analysis, test plans and procedures development, system design, pre-shadow operations, training to FDF ACE maneuver planners, shadow operations, Test Readiness Review (TRR) and finally Operational Readiness Review (ORR) are discussed. These efforts have demonstrated that GMAT is flight quality software ready to support ACE mission operations in the FDF.

mission design↗

Test Bed for Investigating Anomalous Pump Behavior in a Single Phase Mechanically Pumped Flow Loop and Lessons Learned

NASA’s Europa Clipper mission is tasked with investigating the habitability of this icy moon of Jupiter and determining if it is capable of supporting life. The suite of powerful instruments necessary for this mission, combined with the harsh environment, require an elaborate single phase, mechanically pumped flow loop (MPFL) to redistribute waste heat around the spacecraft, thus minimizing energy requirements and avoiding the need for constant heating of the propulsion tanks. At the heart of this MPFL is a pump which will circulate fluid for the entirety of the 12-year mission; however, during initial qualification testing, anomalous behavior raised serious concerns regarding the pump and system design. Due to the critical nature of the pump, a major investigation was launched to evaluate the pump, system design, and the testing methodology employed to investigate this anomaly. This investigation resulted in a highly detailed analysis of the test loop, revised procedures, and the isolation/removal of variables impacting the quality of the observed pump behavior. The resulting test loop permitted comprehensive monitoring of the pump in the MPFL, including: flow rate, inlet and outlet static pressures, temperature, power consumption, and pump speed. Additionally, the investigation of the anomaly revealed several key lessons learned and helped institute a new set of best practices for future MPFL tests.

Miers, Collier↗

RCCS Testing with the Water-based NSTF: Year-1 Single-Phase Results

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large scale test facility has been constructed to generate validation data for passive decay heat removal systems of advanced reactors. Located at Argonne National Laboratory, the Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS). This report serves as a summary of the single-phase testing results obtained during the programs first year of matrix testing. An introduction to the high-level program objectives is first presented, followed by a brief summary of facility design, instrumentation, and control systems. Details of the NQA-1 driven test method are included, which govern the programs quality assurance requirements and provide a background for the testing strategy and procedures. Checkout activities, including verification of gross system mass and energy balances, heat loss quantification, and isothermal facility characterization, were performed early in the first year and results presented in this report. These tests have identified relevant facility characteristics such as K-factors, frictional pressure losses, parasitic heat loss rates, and transient heating response. Results are then presented from four accepted matrix tests where the facility established a steady-state, single-phase mode of flow operation. All matrix tests were performed with an identical top-level procedure: first initiating a heater power ramp to target levels, and then holding power levels constant until the facilities structural members and network piping reached thermal equilibrium. Upon obtaining stable thermal and hydraulic conditions, active cooling was initiated off of the bulk storage tank to maintain constant riser inlet temperatures of 30°C. This steady-state period was then held for a minimum required duration, at which point the heaters were ramped down and test concluded. The two baseline tests completed reflect conditions prototypic to the full scale plant at both normal operation, and design basis Depressurized Loss of Forced Cooling (DLOFC) conditions. These parameters are defined by full RCCS decay heat loads of 1.4 MWt and 2.1 MWt, which translate to NSTF scale thermal power levels of 34.4 kWt and 51.6 kWt, respectively. Two additional tests were also conducted, which repeated baseline cases but included modification by single parameter variations in decay heat load, or heater power, at 700 kWt, and 2.8 MWt. Finally, a scoping test was performed to demonstrate the facilities ability to operate in a two-phase mode of operation. The facility successfully operated for a 3-hour period at this mode, reaching peak inventory temperatures of 105°C and condensing approximately 50 gallons of boil-off inventory. The testing parameters for this demonstration were based off the design basis DLOFC condition, and will be the reference for new baseline cases as the program moves forward with two-phase matrix testing.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Improved silicon carbide for advanced heat engines

The development of silicon carbide materials of high strength was initiated and components of complex shape and high reliability were formed. The approach was to adapt a beta-SiC powder and binder system to the injection molding process and to develop procedures and process parameters capable of providing a sintered silicon carbide material with improved properties. The initial effort was to characterize the baseline precursor materials, develop mixing and injection molding procedures for fabricating test bars, and characterize the properties of the sintered materials. Parallel studies of various mixing, dewaxing, and sintering procedures were performed in order to distinguish process routes for improving material properties. A total of 276 modulus-of-rupture (MOR) bars of the baseline material was molded, and 122 bars were fully processed to a sinter density of approximately 95 percent. Fluid mixing techniques were developed which significantly reduced flaw size and improved the strength of the material. Initial MOR tests indicated that strength of the fluid-mixed material exceeds the baseline property by more than 33 percent. the baseline property by more than 33 percent.

Whalen, Thomas J.↗

Experimental system for the control of surgically induced infections

The development tests to be performed on the experimental system are described in detail. The test equipment, conditions, and procedures are given. The portable clean room tests include assembly, collapsability, portability, and storage; laminar flow rate; static pressure; air flow pattern; and electrostatic buildup. The other tests are on the ventilation system, human factors evaluation, electrical subsystem, and material compatibility.

Tevebaugh, M. D.↗

Permanent and separable aerospace tubing/ fitting evaluation program, volume 1

The tube fitting evaluation program was conducted to develop a standard overall test program including methods, procedures, and equipment as well as recommended test sequences for qualifying fitting/tubing assemblies. The program consisted of testing the MS flareless (separable) fitting and utilizing the results as baseline data from which all other fittings will be evaluated. Five separable designs and five permanent designs were tested in three sizes with two types of tubing materials. The basic design requirements were 4,000 psi operating pressure within the temperature range of minus 65 F to plus 450 F while also being compatible with 21-6-9 and titanium 3Al-2.5V tubing alloys.

Ursell, C. R.↗

Calibrated Ancillary System (CAS) user's guide, volume 5

The Calibrated Ancillary System (CAS) provides real-time parameters from the orbiter downlink (ancillary data) to the Goddard Space Flight Center (GSFC). This user's guide contains the introduction to the equipment, operation, general procedures, and specific procedures of CAS. Volume 5 describes the testing user mission planning procedures including the bulletin board system and ancillary products procedures. Instructions for viewing the SDT/TDT (shuttle data tape/telemetry descriptor tape) data base and the file management menu are also given.

Source record↗

Technical Evaluation Motor No. 7 (TEM-7)

The Technical Evaluation Motor No. 7 (TEM-7) test was a full-scale, full duration static test firing of a high performance motor-configuration solid rocket motor with nozzle vectoring. The final test report documents the procedures, performance, and results of the static test firing of TEM-7. All observations, discussions, conclusions, and recommendations included in the report are complete and final except for the TEM-7 fixed housing unbond investigation. A presentation and discussion of TEM-7 performance, anomalies, and test result concurrence with the objectives outlined in CTP-0107, Rev A, Space Shuttle Technical Evaluation Motor No. 7 (TEM-7) Static Fire Test Plan are included.

Hughes, Phil↗

Technical Evaluation Motor No. 10 (TEM-10)

Technical Evaluation Motor No. 10 (TEM-10) was static fired on 27 Apr. 1993 at the Thiokol Corporation full-scale motor static test bay, T-24. This final test report documents the procedures, performance, and results of the static test firing of TEM-10. All observations, discussions, conclusions, and recommendations contained are final. Included is a presentation and discussion of TEM-10 performance, anomalies, and test results in concurrence with the objectives outlined in CTP-0110, Revision D, Space Shuttle Technical Evaluation Motor No. 10 (TEM-10) Static Fire Test Plan.

Source record↗

The effects of pilot stress factors on handling quality assessments during US/German helicopter agility flight tests

Flight tests were conducted with two helicopters to study and evaluate the effects of helicopter characteristics and pilot and task demands on performance in nap-of-the-Earth flight. Different, low-level slalom courses were set up and were flown by three pilots with different levels of flight experience. A pilot rating questionnaire was used to obtain redundant information and to gain more insight into factors that influence pilot ratings. The flight test setups and procedures are described, and the pilot ratings are summarized and interpreted in close connection with the analyzed test data. Pilot stress is discussed. The influence of demands on the pilot, of the helicopter characteristics, and of other stress factors are outlined with particular emphasis on how these factors affect handling-qualities assessment.

Pausder, H. J.↗

The effects of pilot stress factors on handling quality assessments during US/German helicopter agility flight tests

Flight tests were conducted with two helicopters to study and evaluate the effects of helicopter characteristics and pilot and task demands on performance in nap-of-the-earth flight. Different, low-level slalom courses were set up and were flown by three pilots with different levels of flight experience. A pilot rating questionnaire was used to obtain redundant information and to gain more insight into factors that influence pilot ratings. The flight test setups and procedures are described, and the pilot ratings are summarized and interpreted in close connection with the analyzed test data. Pilot stress is discussed. The influence of demands on the pilot, of the helicopter characteristics, and of other stress factors are outlined with particular emphasis on how these factors affect handling-qualities assessment. Previously announced in STAR as N83-13114

Pausder, H.-J.↗

High-resolution surface photometry of elliptical galaxies

High-resolution CCD surface photometry profiles have been obtained for a sample of 42 nearby elliptical and SO galaxies as a first step in a program to investigate their central structure and core properties. A comparison of the present profiles to those of other observers shows that the accuracy of the central surface brightnesses is to better than 0.02 mag rms. Central resolution is limited by the atmospheric seeing PSF which is measured for each profile. A hybrid Fourier deconvolution procedure has been developed to correct the surface photometry for seeing in a model-independent way. Tests of the procedure on simulated galaxy images show that intrinsic core radii equal to the seeing FWHM or larger can be recovered from the observations. Application of the deconvolution procedure to the observed galaxies yields surface photometry profiles of slightly sub-arc second resolution.

Lauer, T. R.↗

Application of a two-equation turbulence model for high speed compressible flows using unstructured grids

Application of a two-equation compressible turbulence model for practical hypersonic flows 18 presented. The solution algorithm is based on solving all of the governing equations simultaneously. Application of the solution procedure to several test cases for compressible flows show good agreement with theoretical predictions and/or other computational results. The solution procedure is employed to investigate the effects of turbulence in Type III and Type IV shock-shock interactions in hypersonic flows in association with adaptive unstructured grids. Computational results for these cases are compared with available experimental data.

Vemaganti, Gururaja R.↗

Optical Testing of Diamond Machined, Aspheric Mirrors for Groundbased, Near-IR Astronomy

The Infrared Multi-Object Spectrometer (IRMOS) is a facility-class instrument for the Kitt Peak National Observatory 4 and 2.1 meter telescopes. IRMOS is a near-IR (0.8-2.5 micron) spectrometer and operates at approximately 80 K. The 6061-T651 aluminum bench and mirrors constitute an athermal design. The instrument produces simultaneous spectra at low- to mid-resolving power (R=lambda/delta lambda= 300-3000) of approximately 100 objects in its 2.8 x 2.0 arcmin field. We describe ambient and cryogenic optical testing of the IRMOS mirrors across a broad range in spatial frequency (figure error, mid-frequency error, and microroughness). The mirrors include three rotationally symmetric, off-axis conic sections, one off-axis biconic, and several flat fold mirrors. The symmetric mirrors include convex and concave prolate and oblate ellipsoids. They range in aperture from 94x86 mm to 286x269 mm and in f-number from 0.9 to 2.4. The biconic mirror is concave and has a 94x76 mm aperture, R(sub x)=377 mm, k(sub x)=0.0778, R(sub y)=407 mm, and k(sub y)=0.1265 and is decentered by -2 mm in X and 227 mm in Y. All of the mirrors have an aspect ratio of approximately 6:1. The surface error fabrication tolerances are less than 10 nm RMS microroughness, 'best effort' for mid-frequency error, and less than 63.3 nm RMS figure error. Ambient temperature (approximately 293 K) testing is performed for each of the three surface error regimes, and figure testing is also performed at approximately 80 K. Operation of the ADE Phaseshift MicroXAM white light interferometer (micro-roughness) and the Bauer Model 200 profilometer (mid-frequency error) is described. Both the sag and conic values of the aspheric mirrors make these tests challenging. Figure testing is performed using a Zygo GPI interferometer, custom computer generated holograms (CGH), and optomechanical alignment fiducials. Cryogenic CGH null testing is discussed in detail. We discuss complications such as the change in prescription with temperature and thermal gradients. Correction for the effect of the dewar window is also covered. We discuss the error budget for the optical test and alignment procedure. Data reduction is accomplished using commercial optical design and data analysis software packages. Results from CGH testing at cryogenic temperatures are encouraging thus far.

Chambers, V. John↗

Ballistic Impact Testing of Aluminum 2024 and Titanium 6Al-4V for Material Model Development

An experimental program is underway to develop a consistent set of material property and impact test data, and failure analysis, for a variety of materials that can be used to develop improved impact failure and deformation models. Unique features of this set of data are that all material property information and impact test results are obtained using identical materials, the test methods and procedures are extensively documented and all of the raw data is available. This report describes ballistic impact testing which has been conducted on aluminum (Al) 2024 and titanium (Ti) 6Al-4vanadium (V) sheet and plate samples of different thicknesses and with different types of projectiles, one a regular cylinder and one with a more complex geometry incorporating features representative of a jet engine fan blade.

Pereira, J. Michael↗