Search NASA⌕ Search

SEARCH · Search NASA

Results for “Testing Procedure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

A Real-Time ANPC Inverter Digital Twin with Integrated Design-For-Trust

The demand for renewable energy has increased over the last few years, and so has the demand for greater expectations within the energy market. This increasing trend has been accompanied by more significant usage of internet-connected devices (IoT), leading to critical electrical infrastructure being connected to the internet. Implementing internet connectivity with such devices and systems provides benefits such as improving the system's performance, facilitating irregularity and anomaly mitigation, and providing additional situational awareness for enhanced decision-making. However, enhancing the connected system with IoT introduces a drawback – a greater vulnerability to cyber-attacks. Cyber-attacks targeting critical infrastructure in the electrical sector have occurred in the United States and Ukraine. These cyber-attacks highlight and expose vulnerabilities that a system inherits when connecting to the internet. These attacks left thousands of customers without electricity for hours until operators could regain control of the electric utility grid. Therefore, to address the vulnerabilities of an internet-connected power electronic device, this work focused on the hardware layer of the system. Implementing a cyber-control system inside the hardware layer can significantly reduce the possibility of an attacker patching malicious controller firmware into a photovoltaic grid-connected inverter, thus mitigating the likelihood that the inverter becomes inactive a cyber-attack scenario. With this mitigation technique, if a cyberattack is successful and an attacker gains control of the network, a cyber-defense technique is in place to mitigate the impact of the cyber-attack. This additional protection layer was developed based on an innovative concept known as Digital Twin (DT). A DT, in this case, replicates an Active-Neutral Point Clamped (ANPC) inverter and was designed using a hardware language known as VHDL (Very High-Speed Integrated Circuit Hardware Description Language) and applied to Field-Programmable-GateArray (FPGA). The DT is embedded within the FPGA and contained in a controller board, the UCB (Unified Controller Board), developed by the University of Arkansas electrical engineering team. This UCB also contains two Digital Signal Processors (DSPs) responsible for generating associated signals to control an authentic physical inverter. These DSP signals are received and processed by the FPGA that implements the DT of an ANPC; in other words, it simulates in realtime the expected output of an actual ANPC inverter using the signals from the DSP. When a new firmware is ready to be patched, the DT provides output signals simulating behavior that a real ANPC inverter would generate with the new firmware. The new firmware is tested to check if it meets all the operational requirements established using a Design-For-Trust technique (DFTr). If the new firmware fails in at least one of the DFT tests, it is considered malicious and must be rejected. This work is divided into sections, such as Background, which explains the pieces that were used and the strategy behind this work; Process and Procedure, which explains the methodology that was adopted to prove the reliability and effectiveness of this work; Results and Discussion, where the simulations and results are described and explained; followed by Conclusion and Future work section, which concludes this work and adds possible future projects to continue this work further.

do Amaral Custodio, Paulo Vitor↗

FY25 status report on the addition of candidate materials in Class B Code Case

This report provides the time-dependent allowable stress calculation strategy leveraging the limited creep rupture tests data generated to support the allowable stress for 100,000 hours in American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (BPVC), Section II, Part D. A variable confidence index procedure to extrapolate material properties to support 500,000 hours design life is discussed. Time-dependent allowable stresses for Class B component design and analysis are presented for Grade 1 and Grade 2 of Alloy 625. The presented data extrapolation and allowable stress calculation method will support new material addition using limited creep rupture data in the new ASME Boiler and BPVC, Section III, Division 5, Class B rules.

Part D↗

A three-layer magnetic shielding for the MAIUS-1 mission on a sounding rocket

Bose-Einstein-Condensates (BECs) can be used as a very sensitive tool for experiments on fundamental questions in physics like testing the equivalence principle using matter wave interferometry. Since the sensitivity of these experiments in ground-based environments is limited by the available free fall time, the QUANTUS project started to perform BEC interferometry experiments in micro-gravity. After successful campaigns in the drop tower, the next step is a space-borne experiment. The MAIUS-mission will be an atom-optical experiment that will show the feasibility of experiments with ultra-cold quantum gases in microgravity in a sounding rocket. The experiment will create a BEC of 10{sup 5} {sup 87}Rb-atoms in less than 5 s and will demonstrate application of basic atom interferometer techniques over a flight time of 6 min. The hardware is specifically designed to match the requirements of a sounding rocket mission. Special attention is thereby spent on the appropriate magnetic shielding from varying magnetic fields during the rocket flight, since the experiment procedures are very sensitive to external magnetic fields. A three-layer magnetic shielding provides a high shielding effectiveness factor of at least 1000 for an undisturbed operation of the experiment. The design of this magnetic shielding, the magnetic properties, simulations, and tests of its suitability for a sounding rocket flight are presented in this article.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EPRI/DOE High Burnup Fuel Sister Pin Test Plan Simplification and Visualization

The EPRI/DOE High Burnup Confirmatory Data Project (herein called the "Demo") is a multi-year, multi-entity confirmation demonstration test with the purpose of providing quantitative and qualitative data to show how high-burnup fuel ages in dry storage over a ten-year period. The Demo involves obtaining 32 assemblies of high-burnup PWR fuel of four common cladding alloys from the North Anna Nuclear Power Plant, drying them according to standard plant procedures, and then storing them in an NRC-licensed TN-3 2B cask on the North Anna dry storage pad for ten years. After the ten-year storage time, the cask will be opened and the rods will be examined for signs of aging. Twenty-five rods from assemblies of similar claddings, in-reactor placement, and burnup histories (herein called "sister rods") have been shipped from the North Anna Nuclear Power Plant and are currently being nondestructively tested at Oak Ridge National Laboratory. After the non-destructive testing has been completed for each of the twenty-five rods, destructive analysis will be performed at ORNL, PNNL, and ANL to obtain mechanical data. Opinions gathered from the expert interviews, ORNL and PNNL Sister Rod Test Plans, and numerous meetings has resulted in the Simplified Test Plan described in this document. Some of the opinions and discussions leading to the simplified test plan are included here. Detailed descriptions and background are in the ORNL and PNNL plans in the appendices . After the testing described in this simplified test plan h as been completed , the community will review all the collected data and determine if additional testing is needed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

On Distribution Grid Optimal Power Flow Development and Integration

Due to changes in electric distribution grid operation, new operation regimes have been recommended. Distribution grid optimal power flow (DOPF) has received tremendous attention in the research community, yet it has not been fully adopted across the utility industry. Our paper recognizes this problem and suggests a development and integration procedure for DOPF. We propose development of DOPF as a three step procedure of 1) processing the grid, 2) obtaining a tractable solution, and 3) implementing multiple solution algorithms and benchmarking them to improve application reliability. For the integration of DOPF, we demonstrate how a DOPF federate may be developed that can be integrated in a co-simulation environment to mimic the real-world conditions and hence improve its practicality to be deployed in the field. To demonstrate the efficacy of the proposed methods, tests on IEEE 123 bus system are performed where the usage of tractable formulation in DOPF algorithm development and its comparison to the benchmark solution are demonstrated.

Hanif, Sarmad↗

Simplified Predictive Models for CO 2 Sequestration Performance Assessment: Research Topical Report on Task #4 - Reduced-Order Method (ROM) Based Models

Reduced-order models provide a means for greatly accelerating the detailed simulations that will be required to manage CO 2 storage operations. In this work, we investigate the use of one such method, POD-TPWL, which has previously been shown to be effective in oil reservoir simulation problems. This method combines trajectory piecewise linearization (TPWL), in which the solution to a new (test) problem is represented through a linearization around the solution to a previously-simulated (training) problem, with proper orthogonal decomposition (POD), which enables solution states to be expressed in terms of a relatively small number of parameters. We describe the application of POD-TPWL for CO 2 -water systems simulated using a compositional procedure. Stanford’s Automatic Differentiation-based General Purpose Research Simulator (AD-GPRS) performs the full-order training simulations and provides the output (derivative matrices and system states) required by the POD-TPWL method. A new POD-TPWL capability introduced in this work is the use of horizontal injection wells that operate under rate (rather than bottom-hole pressure) control. Simulation results are presented for CO 2 injection into a synthetic aquifer and into a simplified model of the Mount Simon formation. Test cases involve the use of time-varying well controls that differ from those used in training runs. Results of reasonable accuracy are consistently achieved for relevant well quantities. Runtime speedups of around a factor of 370 relative to full- order AD-GPRS simulations are achieved, though the preprocessing needed for POD-TPWL model construction corresponds to the computational requirements for about 2.3 full-order simulation runs. A preliminary treatment for POD-TPWL modeling in which test cases differ from training runs in terms of geological parameters (rather than well controls) is also presented. Results in this case involve only small differences between training and test runs, though they do demonstrate that the approach is able to capture basic solution trends. The impact of some of the detailed numerical treatments within the POD-TPWL formulation is considered in an Appendix.

Mishra, Srikanta↗

Fast and Accurate Core Analysis by the Full-Immersion Pressure-Pulse Decay: Part 1—Theory

Summary Core-scale measurements are considered the ground truth that oil and gas or electric utility companies use to predict the migration of fluids such as oil, natural gas, carbon dioxide, or brine deep underground during their extraction or injection operations. To provide a greater understanding of petrophysical properties of low-permeability geologic formations such as shales and tight gas sandstones, this study introduces a novel core-analysis procedure. The technique follows conventional pressure-pulse-decay permeametry, where the pressure in an inlet chamber adjacent to a cylindrical core plug undergoes a rapid pressurization, the system is shut in, and the pressure reaches a new equilibrium. However, unlike a standard unidirectional pressure-pulse decay, the full-immersion pressure-pulse decay (Hannon 2019) applies a pressure disturbance to the entire outer surface area of the sample. This article covers the numerical simulator designed to model flow through an anisotropic porous sample in this scenario. The model assumes distinct but uniform permeabilities along the radial and axial directions of the cylindrical plug sample. When extracting a plug vertically (or perpendicular to bedding), the permeability along the radial direction associates with the horizontal permeability (i.e., parallel to bedding), whereas in the axial direction, flow occurs perpendicular to bedding (a vertical permeability). Investigations of these model outputs demonstrate an approximately 20-fold decrease in time to complete a full-immersion experiment compared with conventional pressure-pulse decay. Furthermore, the pressure-decay curves resulting from the full-immersion method have slightly different shapes than those resulting from other unidimensional transient methods. These differences begin to demonstrate that, under achievable experimental conditions, the analysis of pressure data from one full-immersion test could enable the simultaneous estimation of the apparent permeabilities parallel and perpendicular to bedding of a cylindrical sample in addition to its porosity. A follow-up article finalizes the proof of this capability with a parameter-estimation procedure and presents experimental verification through a proof-of-concept study. Described in greater detail in that article, the parameter estimator requires multiple forward simulations to analyze the data, which behooves minimizing the compute time for each simulation. By using an alternating direction implicit time-marching scheme and a structured but variably spaced grid, the numerical simulator built for this purpose provides a forward model output with suitable accuracy in approximately 0.5 seconds.

Energy & Fuels↗

Improved Mobility Control for Carbon Dioxide (CO{sub 2}) Enhanced Oil Recovery Using Silica-Polymer-Initiator (SPI) Gels

SPI gels are multi-component silicate based gels for improving (areal and vertical) conformance in oilfield enhanced recovery operations, including water-floods and carbon dioxide (CO{sub 2}) floods, as well as other applications. SPI mixtures are like-water when pumped, but form light up to very thick, paste-like gels in contact with CO{sub 2}. When formed they are 3 to 10 times stronger than any gelled polyacrylamide gel now available, however, they are not as strong as cement or epoxy, allowing them to be washed / jetted out of the wellbore without drilling. This DOE funded project allowed 8 SPI field treatments to be performed in 6 wells (5 injection wells and 1 production well) in 2 different fields with different operators, in 2 different basins (Gulf Coast and Permian) and in 2 different rock types (sandstone and dolomite). Field A was in a central Mississippi sandstone that injected CO{sub 2} as an immiscible process. Field B was in the west Texas San Andres dolomite formation with a mature water-alternating-gas miscible CO{sub 2} flood. Field A treatments are now over 1 year old while Field B treatments have only 4 months data available under variable WAG conditions. Both fields had other operational events and well work occurring before/ during / after the treatments making definitive evaluation difficult. Laboratory static beaker and dynamic sand pack tests were performed with Ottawa sand and both fields’ core material, brines and crude oils to improve SPI chemistry, optimize SPI formulations, ensure SPI mix compatibility with field rocks and fluids, optimize SPI treatment field treatment volumes and methods, and ensure that strong gels set in the reservoir. Field quality control procedures were designed and utilized. Pre-treatment well (surface) injectivities ranged from 0.39 to 7.9 MMCF/psi. The SPI treatment volumes ranged from 20.7 cubic meters (m{sup 3}, 5460 gallons/ 130 bbls) to 691 m{sup 3} (182,658 gallons/ 4349 bbls). Various size and types of chemical/ water buffers before and after the SPI mix ensured that pre-gelled SPI mix got out into the formation before setting into a gel. SPI gels were found to be 3 to 10 times stronger than any commercially available cross-linked polyacrylamide gels based on Penetrometer and Bulk Gel Shear Testing. Because of SPI’s unique chemistry with CO{sub 2}, both laboratory and later field tests demonstrated that multiple, smaller volume SPI treatments maybe more effective than one single large SPI treatment. CO{sub 2} injectivities in injection well in both fields were reduced by 33 to 70% indicating that injected CO{sub 2} is now going into new zones. This reduction has lasted 1+ year in Field A. Oil production increased and CO{sub 2} production decreased in 5 Field A production wells, offsets to Well #1 injector, for a total of about 2,250 m{sup 3} (600,000 gallons/ 14,250 bbls) of incremental oil production- a $140 / SPI bbl return. Treated marginal production well, Field A Well #2, immediately began showing increased oil production totaling 238 m{sup 3} (63,000 gallons/ 1500 BBLs) over 1 year and an immediate 81% reduced gas-oil ratio.

01 COAL, LIGNITE, AND PEAT↗

Experimental Assessment of a Novel Touchless Interface for Intraprocedural Imaging Review

Purpose: To examine the feasibility of a novel technology platform that enables real-time touchless interaction with radiology images in both a simulated and an actual clinical setting. Materials and Methods: This platform offers three different modes for image interaction. The gesture recognition mode uses a depth camera to detect the user’s hand gestures which are translated to image manipulation commands. The light projection mode uses the same camera to detect finger point-and-tap movements above the icons which are projected on a surface to activate the commands. The capacitive sensing mode is enabled by a handheld, portable device, over which finger movements are detected by capacitive sensors to control the image review. Following initial feedback, light projection and capacitive sensing modes were selected for further testing by comparing with the conventional mode of image interaction in time trials for performing a series of standardized image manipulation tasks. Finally, the usability of the technology platform was examined in actual clinical procedures. Results: The light projection and the capacitive sensing modes were evaluated in the time trials and exhibited 60% and 71% reduction in time, respectively, relative to the control mode (p < 0.001). Clinical feasibility for this platform was demonstrated in three actual interventional radiology cases. Conclusion: Accessing, navigating, and extracting relevant information from patient images intraprocedurally are cumbersome and time-consuming tasks that affect safety, efficiency, and decision-making during image-guided procedures. This study demonstrated that the novel technology addressed this issue by allowing touchless interaction with these images in the sterile field.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Self-calibration performance in stereoscopic PIV acquired in a transonic wind tunnel

Three stereoscopic PIV experiments have been examined to test the effectiveness of self-calibration under varied circumstances. Furthermore, we our measurements taken in a streamwise plane yielded a robust self-calibration that returned common results regardless of the specific calibration procedure, but measurements in the crossplane exhibited substantial velocity bias errors whose nature was sensitive to the particulars of the self-calibration approach. Self-calibration is complicated by thick laser sheets and large stereoscopic camera angles and further exacerbated by small particle image diameters and high particle seeding density. In spite of the different answers obtained by varied self-calibrations, each implementation locked onto an apparently valid solution with small residual disparity and converged adjustment of the calibration plane. Thus, the convergence of self-calibration on a solution with small disparity is not sufficient to indicate negligible velocity error due to the stereo calibration.

47 OTHER INSTRUMENTATION↗

On modeling subgrid-scale macro-structures in narrow twisted channels

Porosity-based subgrid topography models often fail to capture the effects of subgrid-scale topographic features in the interior of coarse grid cells. Existing approaches that modify bottom roughness or a drag coefficient are inadequate for macro-structures (large emergent or submerged obstacles) in subgrid-scale narrow twisted channels. Such structures partially block the cross-sectional area and provide enhanced topographic dissipation – effects that are not well represented by a drag coefficient that scales on a coarse-grid cell-averaged velocity and the cell volume. The relative alignment between mesh and flow further complicates this problem as it makes the subgrid model sensitive to mesh design. In the present study, three new approaches for simulating subgrid-scale macro-structures in narrow channels are proposed. The interior partial-blocking effect of structures is modeled as reduction of grid face-area. The sheltering of flow volumes around obstacles, which leads to topographic dissipation, is modeled by reducing the cell volume in the momentum equation (only). A mesh-shift procedure is designed to optimize mesh alignment for identifiable subgrid features. Combining the three subgrid methods improves the approximation of surface elevation and in-channel flow rate with a coarse-grid model. Tests are conducted for channelized flow using both synthetic domains and real marsh topography. Finally, the new methods reduce the overall mesh dependency of the subgrid model and provides stronger physical connection between effects of macro-structures and their geometry at coarse grid scales.

42 ENGINEERING↗

The attractive concept of simplicity in environmental impact assessment: Perceptions of outcomes in southeastern Brazil

Pressures are mounting for the simplification of environmental impact assessment (EIA). This phenomenon is drawing increasing scholarly attention, but studies have not gone far beyond speculating what could happen as a result of recently implemented or proposed regulatory changes. This paper takes a more longitudinal look at simplified EIAs. The main objective was to analyze the perceived outcomes of a number of simplified EIA processes, using Brazil as the empirical context. More specifically, this paper aimed at understanding: 1) how simplified EIAs have been conceptualized and implemented in southeastern Brazil; and 2) how developers and civil servants in that region perceive the outcomes of simplified EIAs. This study adopted a sequential mixed method research approach. Data was collected through literature reviews, 261 telephone-based interviews and 10 face-to-face interviews. Degrees of EIA simplification can vary significantly within and across jurisdictions. In any case, simplification is often framed as a win-win solution to EIA ineffectiveness, through which regulatory and procedural changes are made to ease the process, while, at the same time, maintaining or providing better environmental protection. This approach is more frequently applied to potentially low-impact processes. Chi-square tests of the data collected through telephone interviews in the Brazilian state of Minas Gerais indicated that developers tend to perceive EIA processes as difficult and slow regardless of how simplified it is. Most civil servants, who were directly involved in the implementation of simplified EIAs in state environmental agencies, argued that simplified EIAs are driven mostly by environmental agencies, as these institutions have long been unable to cope with an ever-increasing load of license applications. Policy outcomes of simplified EIAs in the territory are not sufficiently monitored by state agencies. Civil servants revealed concerns about the potential long term effects of EIA simplification on the ground, as they have had limited resources for audits and inspections. - Highlights: •Simplified EIA is conceptualized. •We analyze how simplified EIA is implemented and perceived in Brazil. •Developers perceived EIA as difficult and slow regardless of how simplified it was. •State agencies' low institutional capacity is a key driver of simplification. •Policy outcomes of simplified EIAs in the territory are not monitored.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Use of proton beams with breast prostheses and tissue expanders

Since the early 2000s, a small but rapidly increasing number of patients with breast cancer have been treated with proton beams. Some of these patients have had breast prostheses or tissue expanders in place during their courses of treatment. Procedures must be implemented to plan the treatments of these patients. The density, kilovoltage x-ray computed tomography numbers (kVXCTNs), and proton relative linear stopping powers (pRLSPs) were calculated and measured for several test sample devices. The calculated and measured kVXCTNs of saline were 1% and 2.4% higher than the values for distilled water while the calculated RLSP for saline was within 0.2% of the value for distilled water. The measured kVXCTN and pRLSP of the silicone filling material for the test samples were approximately 1120 and 0.935, respectively. The conversion of kVXCTNs to pRLSPs by the treatment planning system standard tissue conversion function is adequate for saline-filled devices but for silicone-filled devices manual reassignment of the pRLSPs is required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Learning an Eddy Viscosity Model Using Shrinkage and Bayesian Calibration: A Jet-in-Crossflow Case Study

In this paper, we demonstrate a statistical procedure for learning a high-order eddy viscosity model (EVM) from experimental data and using it to improve the predictive skill of a Reynolds-averaged Navier–Stokes (RANS) simulator. The method is tested in a three-dimensional (3D), transonic jet-in-crossflow (JIC) configuration. The process starts with a cubic eddy viscosity model (CEVM) developed for incompressible flows. It is fitted to limited experimental JIC data using shrinkage regression. The shrinkage process removes all the terms from the model, except an intercept, a linear term, and a quadratic one involving the square of the vorticity. The shrunk eddy viscosity model is implemented in an RANS simulator and calibrated, using vorticity measurements, to infer three parameters. The calibration is Bayesian and is solved using a Markov chain Monte Carlo (MCMC) method. A 3D probability density distribution for the inferred parameters is constructed, thus quantifying the uncertainty in the estimate. The phenomenal cost of using a 3D flow simulator inside an MCMC loop is mitigated by using surrogate models (“curve-fits”). A support vector machine classifier (SVMC) is used to impose our prior belief regarding parameter values, specifically to exclude nonphysical parameter combinations. The calibrated model is compared, in terms of its predictive skill, to simulations using uncalibrated linear and CEVMs. Finally, we find that the calibrated model, with one quadratic term, is more accurate than the uncalibrated simulator. The model is also checked at a flow condition at which the model was not calibrated.

42 ENGINEERING↗

Integrated Water Gas Shift Membrane Reactors Utilizing Novel, Non Precious Metal Mixed Matrix Membrane

Nanoparticles of zeolitic imidazolate frameworks and other related hybrid materials were prepared by modifying published synthesis procedures by introducing bases, changing stoichiometric ratios, or adjusting reaction conditions. These materials were stable at temperatures >300 °C and were compatible with the polymer matrices used to prepare mixed- matrix membranes (MMMs). MMMs tested at 300 °C exhibited a >30 fold increase in permeability, compared to those measured at 35 °C, while maintaining H 2 /CO 2 selectivity. Measurements at high pressure (up to 30 atm) and high temperature (up to 300 °C) resulted in an increase in gas flux across the membrane with retention of selectivity. No variations in permeability were observed at high pressures at either 35 or 300 °C. CO 2 -induced plasticization was not observed for Matrimid®, VTEC, and PBI polymers or their MMMs at 30 atm and 300 °C. Membrane surface modification by cross-linking with ethanol diamine resulted in an increase in H 2 /CO 2 selectivity at 35 °C. Spectrometric analysis showed that the cross-linking was effective to temperatures <150 °C. At higher temperatures, the cross-linked membranes exhibit a H 2 /CO 2 selectivity similar to the uncross-linked polymer. Performance of the polybenzimidazole (PBI) hollow fibers prepared at Santa Fe Science and Technology (SFST, Inc.) showed increased flux and selectivity at 300 °C, which is comparable to a flat PBI membrane. A water-gas shift reactor has been built and currently being optimized for testing under DOE conditions.

36 MATERIALS SCIENCE↗

Analysis of the MST-16 crimp process on cold 304L stainless steel

The purpose of this report is to assess the quality of the MST-16 crimp process through a series of cold experiments and metallographic analyses. Common practice in MST-16 uses a mechanical crimp on 304L stainless steel tubes to prevent radioactive contamination from escaping the tube interior for a variety of experiments. The crimped tubes must pass a leak check to demonstrate their radiological safety. Cold (i.e. non-radioactive samples) 304L tube samples were tested using two different approved crimping devices to assess the quality of the crimps. Each crimp was leak checked, followed by destructive metallographic analysis to determine the quality of both the crimp equipment and procedures used by MST-16 personnel.

42 ENGINEERING↗

Radiological Considerations Supporting the American Medical Isotope Producer Niowave

This report provides a summary of work performed by Savannah River National Laboratory (SRNL) during FY22 in support of Niowave, an American Medical Isotope Production (AMIP) facility. SRNL served in a technical support role, funded by NA-231, supporting Niowave in the beginning of non radiological functional testing of their airport facility in FY22. Through this agreement, SRNL provides Niowave access to subject matter experts (SMEs) for questions that may arise during the drafting of engineering plans, facility policies, and/or response procedures. This report summarizes discussions between SRNL and Niowave about guidance concerning issues with the floor of the hot cells, dispersible removable contamination (beta emitting fission product), hot cell operation specifically utilization of cameras or mirrors, and the process for removing contaminated waste from the hot cell. Lessons learned and other various resources provided to Niowave by SRNL during FY22 are referenced in this report. This work was funded through NNSA’s Office of Material Management and Minimization, Conversion Office (NA-231).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Recovery and Enhanced Upgrading of Rare Earth Elements from Coal-Based Resources: Bioleaching and Precipitation

Rare earth elements (REEs) are of great importance to modern society and their reliable supply is a major concern of many industries that utilize them in metal alloys, semiconductors, electrical equipment, and defense equipment. REEs in the coal waste have been revealed to be an alternative resource for REEs production. In this study, the extraction, recovery, and upgrading of the REEs from coal waste has been realized with the bioleaching and precipitation processes. Reliable and sustainable acid and oxidant production from the oxidation of the pyrite with Acidithiobacillus ferrooxidans to generate acid for leaching were realized in this research. The acidified bioleaching solution was used to extract REEs from coal waste, with 13–14% yields for most REE elements (~72 h of leaching). However, recovery for longer duration tests was significant higher (varies from 40–60% for individual REEs). After extraction, precipitation and separation processes were designed with the aid of Visual Minteq calculations and modeling to concentrate the REEs. With the procedures designed in this research, a final REEs precipitate product containing 36.7% REEs was produced.

01 COAL, LIGNITE, AND PEAT↗