Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thick Target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Photochemically induced deposition of protective alumina coatings onto UV emitting phosphors for Xe excimer discharge lamps

Highlights: • A UV-reactor for the pH induced precipitation of inorganic material is described. • The photolysis of Azide (N{sub 3}{sup −}) leads to a steady pH increase used for precipitation. • A UV induced Al(OH){sub 3} precipitation is used to craft Al{sub 2}O{sub 3} coatings onto YPO{sub 4}:Bi. • The influence of Al{sub 2}O{sub 3} coated onto YPO{sub 4}:Bi with different thicknesses is discussed. • SEM, VUV-spectroscopy and ESA measurements were performed on Al{sub 2}O{sub 3} coated samples. - Abstract: This work concerns the particle coating of the UV-C emitting phosphor YPO{sub 4}:Bi, targeting a stability enhancement of the phosphor material for Xe excimer lamp operation. To this end, the material is coated by the wide band gap material Al{sub 2}O{sub 3}. In order to obtain a thin and homogeneous coating layer, a novel process based on the photochemical cleavage of NaN{sub 3} in water was developed. This results in a slow and continuous enhancement of the pH value due to ongoing NaOH formation, which results in the precipitation of Al(OH){sub 3} from an Al{sub 2}(SO{sub 4}){sub 3} {sub ×} 18H{sub 2}O solution. It turned out that the obtained particle coatings are of much better quality, i.e. homogeneity, compared to coatings made from a wet-chemical homogeneous precipitation process. The morphology and electrochemical properties of Al{sub 2}O{sub 3} coated YPO{sub 4}:Bi are discussed on the basis of optical spectroscopy, ESA measurements, and SEM/EDX investigations.

36 MATERIALS SCIENCE↗

Stress and magnetoelastic properties control of amorphous Fe{sub 80}B{sub 20} thin films during sputtering deposition

In situ stress measurements during sputtering deposition of amorphous Fe{sub 80}B{sub 20} films are used to control their stress and magnetoelastic properties. The substrate curvature induced by the deposited film is measured optically during growth and quantitatively related to the deposition induced accumulated stress. The resulting magnetic properties are later correlated with the measured stress for a wide range of sputtering pressures [(2-25)x10{sup -3} mbar]. A significant tensile stress develops at the film-substrate interface during the early growth stages (initial 2-3 nm). At a critical thickness, a transition is observed from tensile to compressive stress, which is associated with amorphous island coalescence. By further increasing the thickness, a compressive stress follows, which is related to the local distortion induced by the ion peening effect. The Monte Carlo simulations of the sputtering process describe quantitatively the experimental results as a function of the Ar pressure and target bias voltage.

36 MATERIALS SCIENCE↗

Thermal transport properties of polycrystalline tin-doped indium oxide films

Thermal diffusivity of polycrystalline tin-doped indium oxide (ITO) films with a thickness of 200 nm has been characterized quantitatively by subnanosecond laser pulse irradiation and thermoreflectance measurement. ITO films sandwiched by molybdenum (Mo) films were prepared on a fused silica substrate by dc magnetron sputtering using an oxide ceramic ITO target (90 wt %In{sub 2}O{sub 3} and 10 wt %SnO{sub 2}). The resistivity and carrier density of the ITO films ranged from 2.9x10{sup -4} to 3.2x10{sup -3} {omega} cm and from 1.9x10{sup 20} to 1.2x10{sup 21} cm{sup -3}, respectively. The thermal diffusivity of the ITO films was (1.5-2.2)x10{sup -6} m{sup 2}/s, depending on the electrical conductivity. The thermal conductivity carried by free electrons was estimated using the Wiedemann-Franz law. The phonon contribution to the heat transfer in ITO films with various resistivities was found to be almost constant ({lambda}{sub ph}=3.95 W/m K), which was about twice that for amorphous indium zinc oxide films.

36 MATERIALS SCIENCE↗

Thomson parabola spectrometry for gold laser-generated plasmas

The plasma generated from thin gold films irradiated in high vacuum at high intensity ({approx}10{sup 15} W/cm{sup 2}) laser shot is characterized in terms of ion generation through time-of-flight techniques and Thomson parabola spectrometry. Gold ions and protons, accelerated in forward direction by the electric field developed in non-equilibrium plasma, have been investigated. Measurements, performed at PALS laboratory, give information about the gold charge states distributions, the ion energy distributions and the proton acceleration driven as a function of film thickness, laser parameters, and angular emission. The ion diagnostics of produced plasma in forward direction permits to understand some mechanisms developed during its expansion kinetics. The role of the focal position of a laser beam with respect to the target surface, plasma properties, and the possibility to accelerate protons up to energies above 3 MeV has been presented and discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of fabrication conditions on phase formation and properties of epitaxial (PbMg{sub 1/3}Nb{sub 2/3}O{sub 3}){sub 0.67}-(PbTiO{sub 3}){sub 0.33} thin films on (001) SrTiO{sub 3}

The pulsed laser deposition process of 300 nm thick films of Pb(Mg{sub 1/3}Nb{sub 2/3})O{sub 3}){sub 0.67}-(PbTiO{sub 3}){sub 0.33} on (001)-oriented SrTiO{sub 3} was studied by varying deposition pressure, substrate deposition temperature, laser fluence on the target and target-substrate distance. Perovskite phase pure, (001)-oriented, epitaxial smooth films were obtained in a narrow range of deposition parameters. The ferroelectric and dielectric properties of films fabricated within this parameter range still vary significantly. This shows the sensitivity of the system for growth conditions. The best film has a polarization value close to that expected for a (001) poled, stress free single crystal film. All films show deposition conditions dependent variations in the self-bias field. The self-bias is very stable during long cycling for films made at optimum deposition conditions. The piezoelectric coefficients of the films are strongly reduced with respect to bulk single crystal values due to the film clamping. The properties variations are ascribed to changes in the grain boundary properties in which film defects are expected to accumulate. Notably slight off-stoichiometry may cause localized screening charges, affecting specifically the polarization and dielectric constant.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hydro-instability growth of perturbation seeds from alternate capsule-support strategies in indirect-drive implosions on National Ignition Facility

Hydrodynamic instability growth of the capsule support membranes (or “tents”) and fill tubes has been studied in spherical, glow discharge polymer plastic capsule implosions at the National Ignition Facility (NIF). In NIF implosions, the capsules are supported by tents because the nominal 10-μm thick fill tubes are not strong enough to support capsules by themselves. After it was recognized that the tents had a significant impact of implosion stability, new support methods were investigated, including thicker, 30-μm diameter fill tubes and cantilevered fill tubes, as described in this article. A new “sub-scale” version of the existing x-ray radiography platform was developed for measuring growing capsule perturbations in the acceleration phase of implosions. It was calibrated using hydrodynamic growth measurements of pre-imposed capsule modulations with Legendre modes of 60, 90, 110, and 140 at convergence ratios up to ~2.4. Subsequent experiments with 3-D perturbations have studied instability growth of 10-μm and 30-μm thick fill tubes to compare them with 30-nm thick tent perturbations at convergence ratios up to ~3. In other experiments, the perturbations from cantilevered fill tubes were measured and compared to the tent perturbations. The cantilevered fill tubes were supported by 12-μm thick SiC rods, offset by 100 μm, 200 μm, and 300 μm from the capsule surfaces. Based on these experiments, 30-μm thick fill tubes and 300-μm offset cantilevered fill tubes were recommended for further tests using layered deuterium-tritium implosions. In conclusion, the effects of x-ray shadowing during the drive and oxygen-induced perturbations during target assembly produced additional seeds for instabilities and were also measured in these experiments.

42 ENGINEERING↗

Characterization of fast electron divergence and energy spectrum from modeling of angularly resolved bremsstrahlung measurements

Characteristics of fast electrons generated in an intense laser-solid target interaction are studied by modeling angularly resolved bremsstrahlung measurements with a hybrid Particle-In-Cell code, Large Scale Plasmas. The experiment was enacted using the 50 TW Leopard laser at the Nevada Terawatt Facility. A 100 μm thick Cu foil was irradiated by the 15 J, 0.35 ps laser at a peak laser intensity of 2 × 10 19 W/cm 2 . Bremsstrahlung produced by transport and recirculation of the fast electrons in the foil was measured with two differential filter-stack x-ray spectrometers at 22° and 40° from the laser axis. The two-spectrometer signals simultaneously fit by varying single slope temperatures (T hot ) and divergence angles (θ) enable for determining T hot and θ to be 1.1 ± 0.3 MeV and 15° ± 8°, respectively. The T hot inferred from the bremsstrahlung signals agrees with that from an escaped electron measurement, implying that that the bremsstrahlung is predominantly produced by the transport of the high energy fast electrons in the first pass.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of Direct Drive Capsule Fill-Tube Assembly Survivability in Support of the 100 GBar Campaign

Capsule fill-tube target assemblies (CFTAs) for direct-drive have been demonstrated in the past for Laser for Laboratory Energetics (LLE) cryogenic layering studies, evolving and building upon successful deliveries for NIF. The current 100 GigaBar (GBar) campaign requires increased tolerances over prior CFTA work in terms of robustness, cleanliness, reduced fill tube diameter and glue size. To tackle these challenges, GA and LLE are developing a direct drive CFTA that survives all fabrication activities, from assembly, qualification testing and transport to cryogenic layering and target chamber insertion at the OMEGA laser facility. Approximately 55 CFTAs of two main designs have been constructed and tested to date, building off the current LLE cryogenic layering study CFTA design (typically 870 µm diameter x 25 µm thick wall capsule). Variations of glass fill tubes sizes from 30, 20 and 10 µm diameter, which are inserted and glued into the capsule. Testing protocols were developed to enable comparison of different designs against one another and evaluate their robustness at room temperature. The testing protocols include pressure checks, resonant vibration mode sweeps, runout and vibration testing to a power spectral density (PSD) input. In this paper we will compare the different design tradeoffs, measurements and results including glue fillets, sag of the fill tubes under gravity, runout and hysteresis, ringdown response, X-ray imaging of the pipette wall thicknesses, and scanning electron microscope (SEM) images taken of failed fill tubes and glue joints. Assessment of the modal vibration modeling for the designs will be compared against the vibration data. Lastly, a design recommendation is put forth meeting the design constraints, which consists of a polymicro composite tube and 10 µm fill tube, ensuring survivability at cryogenic temperatue, a higher first mode resonance and smaller fuel volume.

100 GBar↗

Computation of the Strain Induced Critical Current Reduction in the 16 T Nb 3 Sn Test Facility Dipole

A test facility dipole is being developed at LBNL, targeting a 16 T field in a 144 mm wide aperture. The magnet uses a block design, with two double-pancake coils. In order to minimize motion under the large Lorentz forces, the coils are preloaded against a thick aluminum shell and iron yoke using bladder and key technology. It is then crucial to verify that the performance of the magnet is not degraded due to strain induced on the Nb 3 Sn conductor during assembly, cool-down and powering. The critical current of extracted strands was measured in a varying background magnetic field and as a function of the applied longitudinal strain. Finite element analysis was used to extract the strain state inside the superconducting strands during magnet assembly and operation. This strain was then compared to the measurements to evaluate potential reversible and irreversible effects on the magnet performances. Here the results suggest that the magnet can reach 16 T with sufficient margin, with no irreversible degradation in the high field region.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Sci—Thur AM: YIS - 07: Design and production of 3D printed bolus for electron radiation therapy

This is a proof-of-concept study demonstrating the capacity for modulated electron radiation therapy (MERT) using 3D printed bolus. Previous reports have involved bolus design using an electron pencil beam model and fabrication using a milling machine. In this study, an in-house algorithm is presented that optimizes the dose distribution with regard to dose coverage, conformity and homogeneity within planning target volume (PTV). The algorithm uses calculated result of a commercial electron Monte Carlo dose calculation as input. Distances along ray lines from distal side of 90% isodose to distal surface of PTV are used to estimate the bolus thickness. Inhomogeneities within the calculation volume are accounted for using coefficient of equivalent thickness method. Several regional modulation operators are applied to improve dose coverage and uniformity. The process is iterated (usually twice) until an acceptable MERT plan is realized, and the final bolus is printed using solid polylactic acid. The method is evaluated with regular geometric phantoms, anthropomorphic phantoms and a clinical rhabdomyosarcoma pediatric case. In all cases the dose conformity is improved compared to that with uniform bolus. The printed boluses conform well to the surface of complex anthropomorphic phantoms. For the rhabdomyosarcoma patient, the MERT plan yields a reduction of mean dose by 38.2% in left kidney relative to uniform bolus. MERT using 3D printed bolus appears to be a practical, low cost approach to generating optimized bolus for electron therapy. The method is effective in improving conformity of prescription isodose surface and in sparing immediately adjacent normal tissues.

60 APPLIED LIFE SCIENCES↗

SU-E-J-222: Feasibility Study of MRI-Only Proton Therapy Planning

Purpose: To assess the dosimetric equivalence of MRI based proton planning vs. single energy x-ray CT. Methods: 8 glioblastoma patients were imaged with CT and MRI after surgical resection. T1-weighted 3DMPRAGE was used to delineate the GTV, which was subsequently rigidly registered to the CT volume. A pseudoCT was generated from the aligned MRI by combining segmentation and atlas-based approaches. The spatial resolution both for pseudo- and real CT was 0.6×0.6×2.5mm. Three orthogonal proton beams were simulated on the pseudoCT. Two co-planar beams were set on the axial plane. The third one was planned parallel to the cranio-caudal (CC) direction. Each beam was set to cover the GTV at 98% of the nominal dose (18Gy). The proton plan was copied and transferred to the real CT, including aperture/compensator geometry. Dose comparison between pseudoCT and CT plan was performed beam-by-beam by quantifying the range shift of dose profile on each slice of the GTV. The GTV’s V{sub 98} was computed for the CT. Results: For beams in axial plane the median absolute value of the range shift was 0.3mm, with 0.9mm and 1.4mm as 95th percentile and maximum, respectively. Worst scenarios were found for the CC beam, where we measured 1.1mm (median), 2.7mm (95thpercentile) and 5mm (maximum). Regardless the direction, beams passing through the surgical site, where metal (Titanium MRI-compatible) staples were present, were mostly affected by range shift. GTV’s V{sub 98} for CT was not lower than 99.3%. Conclusion: The study showed the clinical feasibility of an MRI-alone proton plan. Advantages include the possibility to rely on better soft tissue contrast for target and organs at risk delineation without the need of further CT scan and image registration. Additional investigation is required in presence of metal implants along the beam path and to account for partial volume effects due to slice thickness.

60 APPLIED LIFE SCIENCES↗

SU-F-T-79: Monte Carlo Investigation of Optimizing Parameters for Modulated Electron Arc Therapy

Purpose: Electron arc therapy provides excellent dose distributions for treating superficial tumors along curved surfaces. However this modality has not received widespread application due to the lack of needed advancement in electron beam delivery, accurate electron dose calculation and treatment plan optimization. The aim of the current work is to investigate possible parameters that can be optimized for electron arc (eARC) therapy. Methods: The MCBEAM code was used to generate phase space files for 6 and 12MeV electron beam energies from a Varian trilogy machine. An Electron Multi-leaf collimator eMLC of 2cm thickness positioned at 82 cm source collimated distance was used in the study. Dose distributions for electron arcs were calculated inside a cylindrical phantom using the MCSIM code. The Cylindrical phantom was constructed with 0.2cm voxels and a 15cm diameter. Electron arcs were delivered with two different approaches. The first approach was to deliver the arc as segments of very small field widths. In this approach we also tested the impact of the segment size and the arc increment angle. The second approach is to deliver the arc as a sum of large fields each covering the whole target as seen from the beam eye view. Results: In considering 90 % as the prescription isodose line, the first approach showed a region of buildup proceeding before the prescription zone. This build up is minimizing with the second approach neglecting need for bolus. The second approach also showed less x-ray contamination. In both approaches the variation of the segment size changed the size and location of the prescription isodose line. The optimization process for eARC could involve interplay between small and large segments to achieve desired coverage. Conclusion: An advanced modulation of eARCs will allow for tailored dose distribution for superficial curved target as with challenging scalp cases.

60 APPLIED LIFE SCIENCES↗

Static and Dynamic Ultrasound Imaging of the Iliotibial Band/Fascia Lata: Brief Review of Current Literature and Gaps in Knowledge

Purpose of the Review: The physiopathology of iliotibial band syndrome (ITBS) remains obscure and ultrasound (US) imaging could be a low-cost modality improving our understanding of this condition as well as its diagnosis and management. This brief review synthesizes the up-to-date knowledge on static and dynamic US imaging measurements of the fascia lata and iliotibial band (ITB) in both asymptomatic individuals and patients with ITBS. Recent Findings: Mean ITB thickness values for asymptomatic individuals ranged from 1.10 to 1.95 mm. Only three studies with very small sample size focused on ITBS patients and no quantitative data were reported. All dynamic US imaging studies involved asymptomatic participants. One study demonstrated a lateral movement of the ITB relative to the femoral condyle and a group of investigators showed 3D displacement of the fascia lata. No study could be found on ITB loose connective tissue measurements. Summary: This review clearly indicates a paucity of research in the field of static and dynamic US measures. Measuring the loose connective tissue that lies between the deep fascia layers could be an interesting target to help our understanding of ITBS and improve care for the patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Developing Platinum-Group-Metal-Free Catalysts for Oxygen Reduction Reaction in Acid: Beyond the Single Metal Site

This project is to develop M (x) -N-C catalysts with dense multiple metal center (MMC) sites to meet the DOE 2025 activity target of 0.044 mA/cm 2 at 0.9 V IR-free ., as well as other goals such as durability. We have made important contributions to both catalyst development and fundamental understandings of the active sites in M-N-C catalysts in this project. We successfully made M (x) -N-C catalysts with some multiple metal center (MMC) sites by combining ionothermal carbonization with chemical vapor deposition (CVD). These catalysts, however, are not as active as the most active single-atom Fe-N-C catalysts made by the similar CVD process, owing likely to the low site density and the presence of inorganic Fe species such as iron carbides and nanoparticles. The most significant accomplishments we achieved in this project are: (1) we unraveled the formation pathway of Fe-N 4 sites during pyrolysis step-by-step and identified the trans-metalation mechanism, in collaboration with Deborah Myers and her colleagues at Argonne National Laboratory (ANL); (2) inspired by this finding, we pioneered the CVD synthesis of M-N-C catalysts (M = Mn, Fe, and Co), in which the Fe-N-C catalyst by CVD demonstrated an ORR activity of 33 mA/cm 2 at 0.9 V in H 2 -O 2 proton exchange membrane fuel cells (PEMFCs), very close to the ultimate goal of 35 mA/cm 2 of our project. This catalyst is the first Fe-N-C catalyst that contains only D1 sites without the D2 sites; whereas D1 and D2 sites have been always identified by Mossbauer in previous Fe-N-C catalysts. This finding helps to understand what the D1 and D2 sites are and their roles in catalyzing the ORR. (3) by improving the mass transport of the carbon matrix prior to the CVD process, the revised Fe-N-C catalyst made by CVD delivered a maximum power density of 0.53 W/cm 2 in H 2 -air PEMFCs. The improvement strategy was partly inspired by the computational modeling work by Adam Weber from LBNL, the Co-PI of this project, by developing, coding, and exercising a continuum level model of transport phenomena within a PGM-free catalyst layer. The model demonstrated that local resistances combined with limited site density of the PGM-free catalyst can result in limiting currents and poor polarization performance. The model also gave design guidance for impact of ECSA and overall catalyst-layer thickness. However, both Fe-N-C and Co-N-C catalysts developed by CVD showed poor durability in PEMFCS, in comparison with the traditional M-N-C catalysts synthesized via regular pyrolysis process. Consequently, we did not achieve the proposed durability targets. Despite so, we believe the FeNC-CVD catalysts with the poor durability and D1 sites only provides an excellent platform to understand the degradation mechanism of Fe-N-C in PEMFCs, the most important challenge in the development of M-N-C catalysts.

08 HYDROGEN↗

Lentiviral-mediated transfer of CDNF promotes nerve regeneration and functional recovery after sciatic nerve injury in adult rats

Highlights: •CDNF was successfully transfected by a lentiviral vector into the distal sciatic nerve. •CDNF improved S-100, NF200 expression and nerve regeneration after sciatic injury. •CDNF improved the remyelination and thickness of the regenerated sciatic nerve. •CDNF improved gastrocnemius muscle weight and sciatic functional recovery. -- Abstract: Peripheral nerve injury is often followed by incomplete and unsatisfactory functional recovery and may be associated with sensory and motor impairment of the affected limb. Therefore, a novel method is needed to improve the speed of recovery and the final functional outcome after peripheral nerve injuries. This report investigates the effect of lentiviral-mediated transfer of conserved dopamine neurotrophic factor (CDNF) on regeneration of the rat peripheral nerve in a transection model in vivo. We observed notable overexpression of CDNF protein in the distal sciatic nerve after recombinant CDNF lentiviral vector application. We evaluated sciatic nerve regeneration after surgery using light and electron microscopy and the functional recovery using the sciatic functional index and target muscle weight. HE staining revealed better ordered structured in the CDNF-treated group at 8 weeks post-surgery. Quantitative analysis of immunohistochemistry of NF200 and S-100 in the CDNF group revealed significant improvement of axonal and Schwann cell regeneration compared with the control groups at 4 weeks and 8 weeks after injury. The thickness of the myelination around the axons in the CDNF group was significantly higher than in the control groups at 8 weeks post-surgery. The CDNF group displayed higher muscle weights and significantly increased sciatic nerve index values. Our findings suggest that CDNF gene therapy could provide durable and stable CDNF protein concentration and has the potential to enhance peripheral nerve regeneration, morphological and functional recovery following nerve injury, which suggests a promising strategy for peripheral nerve repair.

60 APPLIED LIFE SCIENCES↗

Aerosol-Assisted Solid Debris Collection for the National Ignition Facility

The National Ignition Facility (NIF) has been completed and has made its first shots on-target. While upcoming experiments will be focused on achieving ignition, a variety of subsequent experiments are planned for the facility, including measurement of cross sections, astrophysical measurements, and investigation of hydrodynamic instability in the target capsule. In order to successfully execute several of these planned experiments, the ability to collect solid debris following a NIF capsule shot will be required. The ability to collect and analyze solid debris generated in a shot at the National Ignition Facility (NIF) will greatly expand the number of nuclear reactions studied for diagnostic purposes. Currently, reactions are limited to only those producing noble gases for cryogenic collection and counting with the Radchem Apparatus for Gas Sampling (RAGS). The radchem solid collection diagnostic has already been identified by NIF to be valuable for the determination and understanding of mix generated in the target capsule's ablation. LLNL is currently developing this solid debris collection capability at NIF, and is in the stage of testing credible designs. Some of these designs explore the use of x-ray generated aerosols to assist in collection of solid debris. However, the variety of harsh experimental conditions this solid collection device will encounter in NIF are challenging to replicate. Experiments performed by Gary Grim et al. at Sandia National Laboratory's RHEPP1 facility have shown that ablation causes a cloud of material removed from an exposed surface to move normal to and away from the surface. This ablation is certain to be a concern in the NIF target chamber from the prompt x-rays, gamma rays, etc. generated in the shot. The cloud of ablated material could interfere with the collection of the desired reaction debris by slowing down the debris so that the kinetic energy is too low to allow implantation, or by stopping the debris from reaching the collection device entirely. Our goal is to use this primary ablation wave to our advantage, by the creation of ionized alkali metal halide salt aerosols. This technique is similar to that used by many particle accelerator groups for gas-jet transport. Ideally the salt would be ablated from a substrate, encounter the reaction debris, agglomerate, and be collected for further study. We have done studies at laser and pulsed-power facilities (Titan laser at LLNL, Trident laser at LANL, Zebra z-pinch at Nevada Terawatt Facility) evaluating the hardiness of materials for placement in the NIF target chamber, as well as testing aerosol generation by the incident x-rays generated in device shots. To test this method's potential success in the NIF environment, we have tested KCl, KI, RbI, and CsI films of 1 and 2 um linear thickness on aluminum and silicon wafer substrates in these aforementioned facilities, at varied distances. These salts do ablate in the presence of sufficient x-ray fluence. Further analysis to quantify the final ablation depth as a function of x-ray fluence is ongoing. Half of each sample was masked with a thick tungsten foil for photon opacity. KCl was the most difficult salt to ablate, from comparing the tungsten-masked side of the samples to the unmasked side of the samples. This is likely due to KCl's absorbance peak being at lower wavelengths than that of KI, {approx}160 nm vs. {approx}220 nm, respectively. Samples with and without collimation were tested to identify if any condensation of these ablated salts occurred after ablation. Visual inspection of the silicon wafer witness plates placed parallel to the direction of the incident photons showed that a vapor was deposited on the wafers next to the collimators. Further analysis with EDS in the case of the collimated samples conclusively identified the vapor as CsI. We also intend to examine samples of bare substrate exposed to the same experimental conditions for post-shot change via SEM images, optical microscopy, and atomic force microscopy (AFM). Furthermore, tests with separated isotopes may be done to reduce background contamination. When sample optimization is complete, we plan to develop a 'catcher' device for these desorbed aerosols. Current ideas include biased grids to either attract the ionized particles to the grid, or repel them towards a collection device.

36 MATERIALS SCIENCE↗

Update Direct-Strike Lightning Environment for Stockpile-to-Target Sequence: Supplement LLNL Subcontract #B568621 Lightning Protection at the Yucca Mountain Waste Storage Facility

The University of Florida has surveyed all relevant publications reporting lightning damage to metals, metals which could be used as components of storage containers for nuclear waste materials. We show that even the most severe lightning could not penetrate the stainless steel thicknesses proposed for nuclear waste storage casks.

42 ENGINEERING↗

Hybrid indirect-drive/direct-drive target for inertial confinement fusion

A hybrid indirect-drive/direct drive for inertial confinement fusion utilizing laser beams from a first direction and laser beams from a second direction including a central fusion fuel component; a first portion of a shell surrounding said central fusion fuel component, said first portion of a shell having a first thickness; a second portion of a shell surrounding said fusion fuel component, said second portion of a shell having a second thickness that is greater than said thickness of said first portion of a shell; and a hohlraum containing at least a portion of said fusion fuel component and at least a portion of said first portion of a shell; wherein said hohlraum is in a position relative to said first laser beam and to receive said first laser beam and produce X-rays that are directed to said first portion of a shell and said fusion fuel component; and wherein said fusion fuel component and said second portion of a shell are in a position relative to said second laser beam such that said second portion of a shell and said fusion fuel component receive said second laser beam.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗