Search NASA⌕ Search

SEARCH · Search NASA

Results for “USER EXPERIENCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Advancing $otsdaq$ for Optimized Data Acquisition

High-energy physics (HEP) experiments demand data acquisition (DAQ) systems capable of orchestrating complex detector operations, high data throughput, and responsive, real-time feedback. Traditional systems often have steep learning curves, making onboarding difficult for new users. The Off-The-Shelf Data Acquisition $otsdaq$ framework was developed to address these issues by providing a modular and flexible interface that is easier to operate while remaining customizable enough for experimental setups. As the upcoming Mu2e experiment prepares for deployment, improving stability, usability, and performance has become increasingly critical. Our work enhances $otsdaq$ with features that streamline visualization, correct data metrics, improve debugging workflows, and stabilize the user interface.

Mohammed, Ali (ORCID:0009000860386626)↗

CMS Analysis and Data Reduction with Apache Spark

Experimental Particle Physics has been at the forefront of analyzing the world's largest datasets for decades. The HEP community was among the first to develop suitable software and computing tools for this task. In recent times, new toolkits and systems for distributed data processing, collectively called "Big Data" technologies have emerged from industry and open source projects to support the analysis of Petabyte and Exabyte datasets in industry. While the principles of data analysis in HEP have not changed (filtering and transforming experiment-specific data formats), these new technologies use different approaches and tools, promising a fresh look at analysis of very large datasets that could potentially reduce the time-to-physics with increased interactivity. Moreover these new tools are typically actively developed by large communities, often profiting of industry resources, and under open source licensing. These factors result in a boost for adoption and maturity of the tools and for the communities supporting them, at the same time helping in reducing the cost of ownership for the end-users. In this talk, we are presenting studies of using Apache Spark for end user data analysis. We are studying the HEP analysis workflow separated into two thrusts: the reduction of centrally produced experiment datasets and the end-analysis up to the publication plot. Studying the first thrust, CMS is working together with CERN openlab and Intel on the CMS Big Data Reduction Facility. The goal is to reduce 1 PB of official CMS data to 1 TB of ntuple output for analysis. We are presenting the progress of this 2-year project with first results of scaling up Spark-based HEP analysis. Studying the second thrust, we are presenting studies on using Apache Spark for a CMS Dark Matter physics search, comparing Spark's feasibility, usability and performance to the ROOT-based analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Genome-Scale 13 C Fluxomics Modeling for Metabolic Engineering of Saccharomyces cerevisiae .

Synthetic biology is a rapidly developing field that pursues the application of engineering principles and development approaches to biological engineering. Synthetic biology is poised to change the way biology is practiced, and has important practical applications: for example, building genetically engineered organisms to produce biofuels, medicines, and other chemicals. Traditionally, synthetic biology has focused on manipulating a few genes (e.g., in a single pathway or genetic circuit), but its combination with systems biology holds the promise of creating new cellular architectures and constructing complex biological systems from the ground up. Enabling this merge of synthetic and systems biology will require greater predictive capability for modeling the behavior of cellular systems, and more comprehensive data sets for building and calibrating these models. The so-called "-omics" data sets can now be generated via high throughput techniques in the form of genomic, proteomic, transcriptomic, and metabolomic information on the engineered biological system. Of particular interest with respect to the engineering of microbes capable of producing biofuels and other chemicals economically and at scale are metabolomic datasets, and their insights into intracellular metabolic fluxes. Metabolic fluxes provide a rapid and easy to understand picture of how carbon and energy flow throughout the cell. Furthermore, we present a detailed guide to performing metabolic flux analysis and modeling using the open source JBEI Quantitative Metabolic Modeling (jQMM) library. This library allows the user to transform metabolomics data in the form of isotope labeling data from a 13 C labeling experiment into a determination of cellular fluxes that can be used to develop genetic engineering strategies for metabolic engineering.The jQMM library presents a complete toolbox for performing a range of different tasks of interest in metabolic engineering. Various different types of flux analysis and modeling can be performed such as flux balance analysis, 13 C metabolic flux analysis, and two-scale 13 C metabolic flux analysis (2S- 13 C MFA). 2S- 13 C MFA is a novel method that determines genome-scale fluxes without the need of every single carbon transition in the metabolic network. In addition to several other capabilities, the jQMM library can make model based predictions for how various genetic engineering strategies can be incorporated toward bioengineering goals: it can predict the effects of reaction knockouts on metabolism using both the MoMA and ROOM methodologies. In this chapter, we will illustrate the use of the jQMM library through a step-by-step demonstration of flux determination and knockout prediction in a complex eukaryotic model organism: Saccharomyces cerevisiae ( S. cerevisiae ). Included with this chapter is a digital Jupyter Notebook file that provides a computable appendix showing a self-contained example of jQMM usage, which can be changed to fit the user's specific needs. As an open source software project, users can modify and extend the code base to make improvements at will, allowing them to share their development work and contribute back to the jQMM modeling community.

-Omics data↗

Forward Physics Facility

High-energy collisions at the High-Luminosity Large Hadron Collider will produce a large number of particles along the beam collision axis, outside of the acceptance of existing LHC experiments. The proposed Forward Physics Facility (FPF), to be located 617--682 meters from the ATLAS interaction point along the beam collision axis and shielded by concrete and rock, will host a suite of experiments to probe Standard Model processes and search for physics beyond the Standard Model. The FPF is supported by a rapidly growing user community of 400 physicists, and four pathfinder detectors that are currently operating at the LHC have already yielded promising results, including the first direct detection of collider neutrinos. Here we provide an Executive Summary, and then briefly summarize the status of the FPF, including its rich science case, the facility itself, the proposed FPF experiments and their technical readiness, the preliminary schedule and budget profile, and plans for international participation. Submitted to the DOE/NSF HEPAP Particle Physics Projects Prioritization Panel~(P5)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hydrogen Permeation Analysis Tool

There is a rising need for the measurement and understanding of hydrogen transport properties in materials for the energy and transportation industries. The Hydrogen Permeation Analysis Tool (HyPAT) provides a user friendly interface for batch analysis of dynamic hydrogen permeation data to calculate the transport properties permeability, solubility, and diffusivity. A built in literature database provides an easy comparison to known values. A common method for measuring these hydrogen transport properties is dynamic pressure rise permeation experiments, for example, those done in the Static Gas Absorption and Permeation (SGAP) experiment at INL. Most laboratories develop individual, in-house codes for data analysis. HyPAT provides a platform that can be adopted by other user groups for such experimental analysis and significantly reduce personnel time spent performing data analysis.

Fuerst, ThomasF↗

Inter-slice bidirectional registration-based segmentation of the prostate gland in MR and CT image sequences

Purpose: Accurate segmentation and volume estimation of the prostate gland in magnetic resonance (MR) and computed tomography (CT) images are necessary steps in diagnosis, treatment, and monitoring of prostate cancer. This paper presents an algorithm for the prostate gland volume estimation based on the semiautomated segmentation of individual slices in T2-weighted MR and CT image sequences. Methods: The proposedInter-Slice Bidirectional Registration-based Segmentation (iBRS) algorithm relies on interslice image registration of volume data to segment the prostate gland without the use of an anatomical atlas. It requires the user to mark only three slices in a given volume dataset, i.e., the first, middle, and last slices. Next, the proposed algorithm uses a registration algorithm to autosegment the remaining slices. We conducted comprehensive experiments to measure the performance of the proposed algorithm using three registration methods (i.e., rigid, affine, and nonrigid techniques). Results: The results with the proposed technique were compared with manual marking using prostate MR and CT images from 117 patients. Manual marking was performed by an expert user for all 117 patients. The median accuracies for individual slices measured using the Dice similarity coefficient (DSC) were 92% and 91% for MR and CT images, respectively. The iBRS algorithm was also evaluated regarding user variability, which confirmed that the algorithm was robust to interuser variability when marking the prostate gland. Conclusions: The proposed algorithm exploits the interslice data redundancy of the images in a volume dataset of MR and CT images and eliminates the need for an atlas, minimizing the computational cost while producing highly accurate results which are robust to interuser variability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Data Science and Computation for Rapid and Dynamic Compression Experiment Workflows at Experimental Facilities, September 8-11, 2020. Workshop Report

The application of high pressure to materials has enabled discoveries in scientific fields such as planetary science, materials science, and materials synthesis. Recent advances in X-ray user light sources and other facilities, co-location and integration of user facilities with high-pressure drivers, availability of high-performance computing (HPC) platforms, and the development of new data science techniques have created opportunities for, and challenges in, advancing data analytics for rapid and dynamic compression experiments. To address these challenges, harness the emerging technology now available, and expedite scientific discovery, Los Alamos National Laboratory (LANL) hosted a virtual workshop entitled “Data Science and Computation for Rapid and Dynamic Compression Workflows at Experimental Facilities” from September 8 to 11, 2020. The workshop included 95 registered scientists and analytics experts from 15 universities, 9 United States (US) national laboratories, 5 US and European X-ray light sources, neutron sources such as the Los Alamos Neutron Science Center (LANSCE), other big science facilities such as the National Ignition Facility (NIF), and an industry representative. The workshop included 31 invited talks and 4 lightning talks by students and postdocs.

36 MATERIALS SCIENCE↗

SYS-5620-Project - Achieving Robust Laser Performance utilizing Historical Shot Experiments - A Systems Engineering Proposal

The National Ignition Facility (NIF) at Lawrence Livermore National Laboratory precisely guides, amplifies, reflects, and focuses 192 powerful laser beams into a target about the size of a pencil eraser in a few billionths of a second, delivering more than 2 million joules of ultraviolet energy and 500 trillion watts of peak power. A crucial goal of the system is to trigger precise implosions of fuel capsules. This is achieved by delivering all 192 beams at user-specified times and locations on the target, minimizing any deviation from the requested performance. Power requirements can vary substantially on each experiment and the facility supports numerous amplifier pumping configurations and their attendant nonlinear effects. To achieve the tight performance required across such a broad array of configurations, constant comparison of measured and requested power delivery are tracked and long-term trends analyzed as a guide to understanding future performance. A very common question asked is given the current state of the laser today – how well would a similar experiment from the past perform today? Additionally, if one were to specify an alternate amplifier configuration using today’s model would and damage limits be exceeded and would there be an increase in performance. The physics model used to make these predictions and equipment protection checks is called the Virtual Beamline (VBL). VBL is used with an incoming desired pulse shape and energy to be delivered on target, and then does an iterative solve to predict the needed injected pulse in the front-end of the system to achieve this result. To effectively guide and predict future NIF experiment performance, laser scientists explore current amplifier configurations and compare them with historical data utilizing a tool called the Reverify Toolbox.

42 ENGINEERING↗

Summary of recent experiments on focusing of target-normal-sheath-accelerated proton beam with a stack of conducting foils

We present a summary of recent experiments on focusing of laser target-normal-sheath-accelerated (TNSA) proton beam with a stack of thin conducting foils. The experiments were performed using the Phelix laser (GSI-Darmstadt) and the Titan laser, Lawrence Livermore National Laboratory. The phenomena consistent with self-collimation (or weak self-focusing) of TNSA protons were experimentally observed for the first time at the Phelix laser user facility, in a specially engineered structure ('lens') consisting of a stack of 300 thin aluminum foils separated by 50 μm vacuum gaps. Follow up experiments using the Titan laser obtained results consistent with the collimation/focusing observed in the initial experiments using the Phelix. The Titan experiments employed improved, 25 μm- and 50 μm-gap targets and the new fine mesh diagnostic. All the experiments were carried out in a “passive environment,” i.e., no external fields were applied, and no neutralization plasma or injection of secondary charged particles was imposed. A plausible interpretation of the observed phenomena is that the combination of magnetic self-pinch forces generated by the beam current together with the simultaneous reduction of the repulsive electrostatic forces due to the conducting foils inhibits radial expansion of the beam.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cross-talk compensation in atomic force microscopy

In this work, calibration and correction of cross-talk in atomic force microscopy (AFM) is demonstrated. Several reasons and effects of this inherent problem on experimental results are discussed. We propose a general procedure that can be used on most AFM systems to compensate for cross-talk on the cantilever bending and twisting signals. The method utilizes two initial experiments on a flat surface to achieve an affine transformation between the measured signals and the actual signals. Using this transformation directly on the voltage signals allows us to remove the detrimental effects of cross-talk on AFM-based force measurement experiments. The achieved transformation matrix can be turned into a simple circuit and applied online, by users who have access to the raw signals in the AFM head. As a case study, a lateral deflection based mechanical characterization test for a poly(methyl methacrylate) microfiber that is suspended on a trench is investigated in terms of the effectiveness of the cross-talk compensation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation and performance of SIBYLS: a dual endstation small-angle X-ray scattering and macromolecular crystallography beamline at the Advanced Light Source

The SIBYLS beamline (12.3.1) of the Advanced Light Source at Lawrence Berkeley National Laboratory, supported by the US Department of Energy and the National Institutes of Health, is optimized for both small-angle X-ray scattering (SAXS) and macromolecular crystallography (MX), making it unique among the world's mostly SAXS or MX dedicated beamlines. Since SIBYLS was commissioned, assessments of the limitations and advantages of a combined SAXS and MX beamline have suggested new strategies for integration and optimal data collection methods and have led to additional hardware and software enhancements. Features described include a dual mode monochromator [containing both Si(111) crystals and Mo/B 4 C multilayer elements], rapid beamline optics conversion between SAXS and MX modes, active beam stabilization, sample-loading robotics, and mail-in and remote data collection. These features allow users to gain valuable insights from both dynamic solution scattering and high-resolution atomic diffraction experiments performed at a single synchrotron beamline. Key practical issues considered for data collection and analysis include radiation damage, structural ensembles, alternative conformers and flexibility. SIBYLS develops and applies efficient combined MX and SAXS methods that deliver high-impact results by providing robust cost-effective routes to connect structures to biology and by performing experiments that aid beamline designs for next generation light sources.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser Ablation Reducer Application

The LARA code imports laser ablation experiments data and reduces the data according to mass and IC gain standards selected by the user. It produces graphics illustrating the results, and writes output data to file. The LARA code was developed in R, and is run within a session of RStudio.

Samperton, KyleM.↗

ROSE

Developed at Lawrence Livermore National Laboratory (LLNL), ROSE is an open source compiler infrastructure to build source-to-source program transformation and analysis tools for large-scale C (C89 to C23), C++ (C++98 to C++23), UPC, Fortran (Fortran4, 66, 77, 95, 2003), OpenMP, Java, Python, and Binary applications. ROSE users range from experienced compiler researchers to library and tool developers who may have minimal compiler experience. ROSE is particularly well suited for building custom tools for static analysis, program optimization, arbitrary program transformation, domain-specific optimizations, complex loop optimizations, performance analysis, and cyber-security. ROSE is: A library (and set of associated tools) to quickly and easily apply compiler techniques to one's code in order to improve application performance and developer productivity. A research and development compiler infrastructure for for writing custom source-to-source translators to perform source code transformations, analysis, and optimizations. Is

Pinnow, NathanT [Lawrence Livermore National Labor↗

A Slag Management Toolset for Determining Optimal Coal Gasification Temperatures

Abstract Gasifier operation is an intricate process because of the complex relationship between slag chemistry and temperature, limitations of feedstock materials, and operational preference. High gasification temperatures increase refractory degradation, while low gasification temperatures can lead to slag buildup on the gasifier sidewall or exit, either of which are problematic during operation. Maximizing refractory service life and gasifier performance require finding an optimized operating temperature range which is a function of the coal slag chemistry and viscosity. Gasifier operators typically use a slag’s viscosity-temperature relationship and/or ash-fusion fluid temperature to determine the gasification temperature range. NETL has built a slag management toolset to determine the optimal temperature range for gasification of a carbon feedstock. This toolset is based on a viscosity database containing experimental data, and a number of models used to predict slag viscosity as a function of composition and temperature. Gasifier users typically have no scientific basis for selecting an operational temperature range for gasification, instead using experience to select operational conditions. The use of the toolset presented in this paper provides a basis for estimating or modifying carbon feedstock slags generated from ash impurities in carbon feedstock.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CROCUS Air Quality Data at Northeastern Illinois University Rooftop

This dataset is from the Department of Energy Office of Science funded project, Community Research on Urban and Climate Science (CROCUS) (https://crocus-urban.org/). The AQT (Vaisala AQT530) instrument provides observations on meteorological conditions, including particulate matter (PM2.5, PM10), gas species concentrations (NO, NO2, O3, CO), and environment temperature and moisture. These measurements are critical for understanding air quality. These measurements are useful for understanding changes in aerosol properties, air quality research, and comparing to model experiments especially in urban environments.Datasets are stored in the netCDF data format, and we we encourage users to make use the associated toolkits available from Unidata (https://www.unidata.ucar.edu/software/netcdf/), Project Pythia (https://foundations.projectpythia.org/core/data-formats/netcdf-cf.html), and our “Instrument Cookbooks” (https://crocus-urban.github.io/instrument-cookbooks) for more information on how to process the metadata-rich datasets.

54 ENVIRONMENTAL SCIENCES↗

Project X: Accelerator Reference Design

Project X is a high-intensity proton facility being developed to support a world-leading program of Intensity Frontier physics over the next two decades at Fermilab. Project X is an integral part of the U.S. Intensity Frontier Roadmap as described in the P5 report of May 2008 [1] and within the Fermilab Strategic Plan of November 2011 [2]. This document represents Part I of the “Project X Book” describing the Project X accelerator facility and the broad range of physics research opportunities enabled by Project X. Parts II and III provide in-depth descriptions of the physics research program, both within and beyond particle physics [3]. The primary elements of the U.S. program to be supported by Project X include: Neutrino Experiments: Experimental studies of neutrino oscillations and neutrino interaction physics with ultra-intense neutrino beams provided by a high-power proton source with energies up to 120 GeV, utilizing near detectors at the Fermilab site and massive detectors at distant underground laboratories. Goal: At least 2 MW of proton beam power at any energy between 60 to 120 GeV; several hundred kW of proton beam power on target at 8 GeV. Kaon, Muon, Nucleon, and Neutron Precision Experiments: World-leading experiments studying ultra-rare kaon decays, searching for muon-to-electron conversion and nuclear electron dipole moments (EDMs), and exploring neutron properties at very high precision. Goal: MW-class proton beams supporting multiple experiments at 1 and 3 GeV, with flexible capability for providing distinct beam formats to concurrent users while allowing simultaneous operations with the neutrino program. Material Science and Nuclear Energy Applications: High-intensity accelerator, spallation, target and transmutation technology demonstrations will provide critical input into the design of future energy systems, including next generation fission reactors, nuclear waste transmutation systems and future thorium fuel-cycle power systems. Possible applications of muon spin rotation techniques provide sensitive probes of the magnetic structure of materials. Goal: Provide MW-class proton beams at 1 GeV, coupled with novel targets required to support a broad range of materials science and energy applications. Platform for Evolution to Future Frontier Facilities: A high-intensity proton source will strengthen and modernize the Fermilab injector complex, providing a robust platform upon which to build future frontier facilities. The Neutrino Factory and Muon Collider are examples that would provide world-leading capabilities at the Intensity and Energy Frontiers for many decades to come. Goal: Provide a straightforward upgrade path for a 4 MW, low-duty-factor source of protons at energies between 5 and 15 GeV. These four elements are expected to form the basis of the Mission Need statement required for the Department of Energy (DOE) Critical Decision 0 (CD-0), and represent the fundamental design criteria for Project X. The following chapters present the Reference Design for the Project X accelerator facility. The Reference Design is based on a continuous wave (CW) superconducting (SC) linac providing up to 1 and 3 MW of beam power at 1 and 3 GeV respectively. A pulsed linac provides acceleration of roughly 4% of the beam delivered from the CW linac to the 8 GeV injection energy of the existing Recycler/Main Injector complex. Upgrades to the Recycler and Main Injector support a factor of three increase, beyond current capabilities, in proton beam power at 60 to 120 GeV. The Reference Design represents a facility that will be unique in the world with unmatched capabilities for the delivery of very high beam power, with flexible beam formats, to multiple users at multiple energies. The utilization of linacs within the Project X facility enables capabilities beyond what is achievable with circular accelerators. It is anticipated that the final configuration and operating parameters of the complex will be further refined through the R&D program in advance of CD-2.

Holmes, Stephen D.↗

Application of pixel-cell detector technology for Advanced Neutron Beam Monitors

Application of Pixel-Cell Detector Technology for Advanced Neutron Beam Monitors Specifications of currently available neutron beam detectors limit their usefulness at intense neutron beams of large-scale national user facilities used for the advanced study of materials. A large number of neutron-scattering experiments require beam monitors to operate in an intense neutron beam flux of >10E+7 neutrons per second per square centimeter. For instance, a 4 cm x 4 cm intense beam flux of 6.25 x 10E+7 n/s/cm2 at the Spallation Neutron Source will put a flux of 1.00 x 10E+9 n/s at the beam monitor. Currently available beam monitors with a typical efficiency of 1 x 10E-4 will need to be replaced in less than two years of operation due to wire and gas degradation issues. There is also a need at some instruments for beam position information that are beyond the capabilities of currently available He-3 and BF3 neutron beam monitors. ORDELA, Inc.’s research under USDOE SBIR Grant (DE-FG02-07ER84844) studied the feasibility of using pixel-cell technology for developing a new generation of stable, long-life neutron beam monitors. The research effort has led to the development and commercialization of advanced neutron beam detectors that will directly benefit the Spallation Neutron Source and other intense neutron sources such as the High Flux Isotope Reactor. A prototypical Pixel-Cell Neutron Beam Monitor was designed and constructed during this research effort. This prototype beam monitor was exposed to an intense neutron beam at the HFIR SNS HB-2 test beam site. Initial measurements on efficiency, uniformity across the detector, and position resolution yielded excellent results. The development and test results have provided the required data to initiate the fabrication and commercialization of this next generation of neutron-detector systems. ORDELA, Inc. has (1) identified low-cost design and fabrication strategies, (2) developed and built pixel-cell detectors and instrumented a 64-pixel-cell detector to specifications for the Cold-Neutron Chopper Spectrometer and POWGEN instruments, (3) investigated the general characteristics of this technology, (4) studied pixel-cell configurations and arrived at an optimized modular design, and (5) evaluated fabrication costs of mass production for these configurations. The resulting technology will enable a complete line of pixel-cell-based neutron detectors to be commercially under available. ORDELA, Inc has a good track history of application of innovative technology into the marketplace. Our commercialization record reflects this. For additional information, please contact Daniel Kopp at ORDELA, Inc. at +1 (865) 483-8675 or check our website at www.ordela.com.

36 MATERIALS SCIENCE↗

Metal Bellows Valve Reliability Testing

Swagelok B ® series metal bellows-sealed valves were tested for their cycle performance longevity to evaluate their use in tritium service. The valves selected differed in the size of their pneumatic actuator and the stem tip material. Valves tested had one of three actuator sizes (1C, 3C, or 5C) and one of two stem tip materials: a cobalt-based metal, Stellite™, and a polyimide material, Vespel ® . An automated valve manifold was constructed, allowing for the simultaneous cycling of a total of 10 valves. Automation controls allowed for user inputs, controlling the number of valve cycles per test and the number of tests per experiment. Valves installed on the valve testing manifold to be cycled following a valve frequency test plan. After a defined number cycles, the valves would undergo leak testing using an inline leak detector. The inline helium leak detector provided qualitative detection of any failing or failed valves. If a valve had failed, a leak rate greater than at 1.0 x 10 -7 std cc He/sec, the valve would be removed from the manifold and quantitative leak rate measurements made. After specific cycling milestones were reached, quantitative valve leak rate measurements were performed to assess the adequacy of the qualitative measurement method. Valve evaluation began with initial leak tests: valve inlet/outlet seat rates and total body leak rate. The as received 1C valves, with PTFE stem tips, passed initial leak tests; however, stem tips replacements with either metal or polyimide stem tips essentially created valves which failed subsequent leak tests and were not subject to valve cycling. The 3C actuated valves had been cycled 150,000 times, resulting in 60% of the Stellite™ and Vespel ® tipped valves still passing the leak rate criteria. Failure analysis on the other 40% has yet to be conducted. Eight of the 5C valves had reached 150,000 cycles with 80% of the valves passing the leak rate criteria: two Vespel ® tipped 5C valves failed leak rate testing after 120,000 cycles.

36 MATERIALS SCIENCE↗