Search NASA⌕ Search

SEARCH · Search NASA

Results for “Verification study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Verification of MCNP5-1.60 and MCNP6.1 for Criticality Safety Applications

To verify that both MCNP5-1.60 and MCNP6.1 are performing correctly for criticality safety applications, several suites of verification/validation benchmark problems were run in early 2013. Results from these benchmark suites were compared with results from previously verified versions of MCNP5.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Coarse-grained simulations of vortex dynamics and transition in complex high-Re flows

Turbulent flow complexity in applications in engineering, geophysics and astrophysics typically requires achieving accurate and dependable large scale predictions of highly nonlinear processes with under-resolved computer simulation models. Laboratory observations typically demonstrate the end outcome of complex non-linear three-dimensional physical processes with many unexplained details and mechanisms. Carefully controlled computational experiments based on the numerical solution of the conservation equations for mass, momentum, and energy, provide insights into the underlying flow dynamics. Relevant computational fluid dynamics issues to be addressed relate to the modeling of the unresolved tlow conditions at the subgrid scale (SGS) level - within a computational cell, and at the supergrid (SPG) scale - at initialization and beyond computational boundaries. SGS and SPG information must be prescribed for closure of the equations solved numerically. SGS models appear explicitly or implicitly as additional source tenns in the modified flow equations solved by the numerical solutions being calculated, while SPG models provide the necessary set of initial and boundary conditions that must be prescribed to ensure unique well-posed solutions. From this perspective, it is clear that the simulation process is inherently determined by the SGS and SPG information prescription process. On the other hand, observables in laboratory experiments are always characterized by the finite scales of the instrumental resolution of measuring/visualizing devices, and subject as well to SPG issues. It is thus important to recognize the inherently intrusive nature of observations based on numerical or laboratory experiments. Ultimately, verification and validation (V & V) frameworks and appropriate metrics for the specific problems at hand are needed to establish predictability of the simulation model. Direct numerical simulation (DNS) - resolving all relevant space/time scales, is prohibitively expensive in the foreseeable future for most practical flows of interest at moderate-to-high Reynolds number (Re). On the other end of the simulation spectrum are the Reynolds-Averaged Navier-Stokes (RANS) approaches - which model the turbulent effects. In the coarsegrained large eddy simulation (LES) strategies, the large energy containing structures are resolved, the smaller structures are filtered out, and unresolved SGS effects are modeled. By necessity - rather than choice, LES effectively becomes the intermediate approach between DNS and RANS. Extensive work has demonstrated that predictive simulations of turbulent velocity fields are possible using a particular LES denoted implicit LES (ILES), using the class of nonoscillatory finite-volume (NFV) numerical algorithms. Use of the modified equation as framework for theoretical analysis, demonstrates that leading truncation tenns associated with NFV methods provide implicit SGS models of mixed anisotropic type and regularized motion of discrete observables. Tests in fundamental applications ranging from canonical to very complex flows indicate that ILES is competitive with conventional LES in the LES realm proper - flows driven by large scale features. High-Re flows are vortex dominated and governed by short convective timescales compared to those of diffusion, and kinematically characterized at the smallest scales by slender worm vortices with insignificant internal structure. This motivates nominally inviscid ILES methods capable of capturing the high-Re dissipation dynamics and of handling vortices as shocks in shock capturing schemes. Depending on flow regimes, initial conditions, and resolution, additional modeling may be needed to emulate SGS driven physics, such as backscatter, chemical reaction, material mixing, and near-wall flow-dynamics - where typically-intertwined SGS/SPG issues need to be addressed. A major research focus is recognizing when additional explicit models and/or numerical treatments are needed and ensuring that mixed explicit and implicit SGS models can effectively act in collaborative rather than interfering fashion. We survey our present understanding of the theoretical basis of lLES, including connections with the classical LES and finite-scale dynamics perspectives. Examples from recent lLES studies are presented, including canonical turbulence test cases and shock driven turbulence; relevant V & V issues are demonstrated in this context.

58 GEOSCIENCES↗

Monitoring/Verification using DMS: TATP Example

Field-rugged and field-programmable differential mobility spectrometry (DMS) networks provide highly selective, universal monitoring of vapors and aerosols at detectable levels from persons or areas involved with illicit chemical/biological/explosives (CBE) production. CBE sensor motes used in conjunction with automated fast gas chromatography with DMS detection (GC/DMS) verification instrumentation integrated into situational operations management systems can be readily deployed and optimized for changing application scenarios. The feasibility of developing selective DMS motes for a 'smart dust' sampling approach with guided, highly selective, fast GC/DMS verification analysis is a compelling approach to minimize or prevent the use of explosives or chemical and biological weapons in terrorist activities. Two peroxide-based liquid explosives, triacetone triperoxide (TATP) and hexamethylene triperoxide diamine (HMTD), are synthesized from common chemicals such as hydrogen peroxide, acetone, sulfuric acid, ammonia, and citric acid (Figure 1). Recipes can be readily found on the Internet by anyone seeking to generate sufficient quantities of these highly explosive chemicals to cause considerable collateral damage. Detection of TATP and HMTD by advanced sensing systems can provide the early warning necessary to prevent terror plots from coming to fruition. DMS is currently one of the foremost emerging technologies for the separation and detection of gas-phase chemical species. This is due to trace-level detection limits, high selectivity, and small size. DMS separates and identifies ions at ambient pressures by utilizing the non-linear dependence of an ion's mobility on the radio frequency (rf) electric field strength. GC is widely considered to be one of the leading analytical methods for the separation of chemical species in complex mixtures. Advances in the technique have led to the development of low-thermal-mass fast GC columns. These columns are capable of completing runs in less than 3 minutes. Fast GC columns are also more compact than their traditional counterparts. An earlier collaborative effort involving these authors optimized a handheld, fast GC/DMS, equipped with a non-rad ionization source, for the detection of TATP (Figure 2). The unit combines the separation capabilities of GC with the selectivity of DMS. Analytes are identified both by their elution time from the column and by the characteristic response in the DMS spectrum. Analysis times required to obtain results for these analytes are approximately 80 seconds for TATP and 160 seconds for HMTD (Figure 3). The limit of detection for both TATP and HMTD is approximately 1 ng/{micro}L. Substances that could interfere with the detection of peroxide-based explosives have been studied. Both the GC elution time and the DMS spectral peak locations were unique and do not hinder the detection of either TATP or HMTD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Environmental Characterization Scans Using Sodium-Iodide Gamma Spectroscopy to Determine Ra-226 Concentration in Surface Soil - 16326

The recent natural gas drilling boom has brought heightened attention to the issue of TENORM waste management. Radioactive residues from the extraction, treatment, and purification of materials containing uranium and thorium, or their progeny, pose a public health hazard primarily in the form of ground water contamination. Hydraulic fracturing can liberate formation waters from shale; the high salinity of which can cause radium to move with the water to the surface. The disposal and handling of this water has been a subject of public controversy. For soil remediation projects, radium-226 is generally one of the radionuclides of concern due to its alpha emissions. However performing a survey scan for Ra-226 is difficult because its photon emissions are low energy and have minimal probability of emission per decay (186.2 keV, 3.3% abundance). Additionally resolving its emission from U-235 (185.7 keV, 57% abundance) with field instrumentation is not feasible. Therefore detection of Ra-226 relies on the presence and photon emissions of its progeny. This paper outlines methodology for calculating the minimum detectable concentration of Ra-226 in characterization scans using a sodium-iodide detector array coupled with a multi-channel analyzer. Using progeny ingrowth as a detection proxy requires knowing decay time in order to determine progeny emission rates. Knowledge of site history, process, and prior survey results can be key in determining an accurate decay time. However in the absence of such information in-situ measurements can be used to estimate decay time by comparing observed progeny emission ratios against established values. These values are determined using Oak Ridge National Laboratory's ORIGEN-ARP program to generate photon energy spectra for Ra-226 and its progeny at specified time intervals. Once decay time is established, the detector's minimum detectable concentration can be calculated by synthesizing the expected emission spectra and Los Alamos National Laboratory's Monte Carlo N-Particle transport code to simulate detector response. Traditionally, one of the steps in calculating a system's minimum detectable concentration is to place an appropriate button source under the detector, record the response, and then move the source by a specified increment. This process is repeated until the detector's spatial efficiency has been mapped. Due to the impracticality of performing this with Ra-226 button sources of varying decay times, Monte Carlo N-Particle transport code was utilized to determine the detector's spatial efficiency. A dime sized source with the established emission spectra was placed into the center of a rectangle of soil. This rectangle, including the source, was used as a lattice element to fill the region of space below the detector. The simulation was designed to track the energy distribution of pulses created in the sodium iodide crystal using the F8 tally, and was setup to isolate each source; thereby correlating detector response to source position. The simulation output required post-processing to determine conversion factors from counts per second to disintegrations per second. Post-processing accounted for subtraction of the Compton continuum, and average the data over the scanning pattern to obtain the expected spatial sensitivity during a characterization study. This was performed for the following photo-peaks: 609 keV (Bi-214), and 1764 keV (Bi-214). For calculation of the scan minimum detectable concentration, the surveyor efficiency coefficient from NUREG 1507 was supplanted in favor of a scan speed deviation factor. This was used because the detector utilizes computerized data collection (spatial and spectral). This report finds that, for two shielded 10.16 cm x 10.16 cm x 40.64 cm sodium-iodide crystals with integrated multi-channel analyzers, the minimum detectable concentration in surface soils is less than 1 pCi per gram Ra-226 for a 1 second survey measurement. These results assume a volumetric source with a maximum depth of 15.24 cm and a minimum decay time of 21 days. Verification of the system's capabilities was performed by sending soil samples from scanned areas, and locations where in-situ measurements were performed, to an independent laboratory for analysis. The laboratory results demonstrated that scanned area was principally comprised of soil containing less than 1 pCi per gram Ra-226. This borders the system MDC and it underestimated the concentration of radium in the soil. The probable causes of this is escape of radon gas from the surface soil. Radon is the daughter of radium, and has a high mobility in soil. If the gas escapes, then the progeny used as the detection proxy will be present in lower than expected concentrations. Radionuclide identification using high volume sodium-iodide crystals in low level characterization scans is demonstrated to be possible. Further system refinement will focus on developing a methodology to estimate a radon escape factor for site specific use. Accounting for radon escape in the top 15.24 cm of soil will allow the system to better estimate Ra-226 concentrations in soil. This is a significant advancement over the gross counting statistics used in most studies to satisfy MARSSIM survey requirements, because it will increase stakeholder confidence. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimized, Budget-constrained Monitoring Well Placement Using DREAM

Defining the ideal suite of monitoring technologies to be deployed at a carbon capture and storage (CCS) site presents a challenge to project developers, financers, insurers, regulators and other stakeholders. The monitoring, verification, and accounting (MVA) toolkit offers a suite of technologies to monitor an extensive range of parameters across a wide span of spatial and temporal resolutions, each with their own degree of sensitivity to changes in the parameter being monitored. Understanding how best to optimize MVA budgets to minimize the time to leak detection could help to address issues around project risks, and in turn help support broad CCS deployment. This paper presents a case study demonstrating an application of the Designs for Risk Evaluation and Management (DREAM) tool using an ensemble of CO 2 leakage scenarios taken from a previous study on leakage impacts to groundwater. Impacts were assessed and monitored as a function of pH, total dissolved solids (TDS), and trace metal concentrations of arsenic (As), cadmium (Cd), chromium (Cr), and lead (Pb). Using output from the previous study, DREAM was used to optimize monitoring system designs based on variable sampling locations and parameters. The algorithm requires the user to define a finite budget to limit the number of monitoring wells and technologies deployed, and then iterates well placement and sensor type and location until it converges on the configuration with the lowest time to first detection of the leak averaged across all scenarios. To facilitate an understanding of the optimal number of sampling wells, DREAM was used to assess the marginal utility of additional sampling locations. Based on assumptions about monitoring costs and replacement costs of degraded water, the incremental cost of each additional sampling well can be compared against its marginal value in terms of avoided aquifer degradation. Applying this method, DREAM identified the most cost-effective ensemble with 14 monitoring locations. Here, while this preliminary study applied relatively simplistic cost and technology assumptions, it provides an exciting proof-of-concept for the application of DREAM to questions of cost-optimized MVA system design that are informed not only by site-specific costs and technology options, but also by reservoir simulation results developed during site characterization and operation.

47 OTHER INSTRUMENTATION↗

Kilovoltage Intrafraction Monitoring for Prostate Intensity Modulated Arc Therapy: First Clinical Results

Purpose: Most linear accelerators purchased today are equipped with a gantry-mounted kilovoltage X-ray imager which is typically used for patient imaging prior to therapy. A novel application of the X-ray system is kilovoltage intrafraction monitoring (KIM), in which the 3-dimensional (3D) tumor position is determined during treatment. In this paper, we report on the first use of KIM in a prospective clinical study of prostate cancer patients undergoing intensity modulated arc therapy (IMAT). Methods and Materials: Ten prostate cancer patients with implanted fiducial markers undergoing conventionally fractionated IMAT (RapidArc) were enrolled in an ethics-approved study of KIM. KIM involves acquiring kV images as the gantry rotates around the patient during treatment. Post-treatment, markers in these images were segmented to obtain 2D positions. From the 2D positions, a maximum likelihood estimation of a probability density function was used to obtain 3D prostate trajectories. The trajectories were analyzed to determine the motion type and the percentage of time the prostate was displaced {>=}3, 5, 7, and 10 mm. Independent verification of KIM positional accuracy was performed using kV/MV triangulation. Results: KIM was performed for 268 fractions. Various prostate trajectories were observed (ie, continuous target drift, transient excursion, stable target position, persistent excursion, high-frequency excursions, and erratic behavior). For all patients, 3D displacements of {>=}3, 5, 7, and 10 mm were observed 5.6%, 2.2%, 0.7% and 0.4% of the time, respectively. The average systematic accuracy of KIM was measured at 0.46 mm. Conclusions: KIM for prostate IMAT was successfully implemented clinically for the first time. Key advantages of this method are (1) submillimeter accuracy, (2) widespread applicability, and (3) a low barrier to clinical implementation. A disadvantage is that KIM delivers additional imaging dose to the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intrafraction Motion in Stereotactic Body Radiation Therapy for Non-Small Cell Lung Cancer: Intensity Modulated Radiation Therapy Versus Volumetric Modulated Arc Therapy

Purpose: Stereotactic body radiation therapy (SBRT) for early-stage inoperable non-small cell lung cancer (NSCLC) patients delivers high doses that require high-precision treatment. Typically, image guidance is used to minimize day-to-day target displacement, but intrafraction position variability is often not corrected. Currently, volumetric modulated arc therapy (VMAT) is replacing intensity modulated radiation therapy (IMRT) in many departments because of its shorter delivery time. This study aimed to evaluate whether intrafraction variation in VMAT patients is reduced in comparison with patients treated with IMRT. Methods and Materials: NSCLC patients (197 IMRT and 112 VMAT) treated with a frameless SBRT technique to a prescribed dose of 3 × 18 Gy were evaluated. Image guidance for both techniques was identical: pretreatment cone beam computed tomography (CBCT) (CBCT{sub precorr}) for setup correction followed immediately before treatment by postcorrection CBCT (CBCT{sub postcorr}) for verification. Then, after either a noncoplanar IMRT technique or a VMAT technique, a posttreatment (CBCT{sub postRT}) scan was acquired. The CBCT{sub postRT} and CBCT{sub postcorr} scans were then used to evaluate intrafraction motion. Treatment delivery times, systematic (Σ) and random (σ) intrafraction variations, and associated planning target volume (PTV) margins were calculated. Results: The median treatment delivery time was significantly reduced by 20 minutes (range, 32-12 minutes) using VMAT compared with noncoplanar IMRT. Intrafraction tumor motion was significantly larger for IMRT in all directions up to 0.5 mm systematic (Σ) and 0.7 mm random (σ). The required PTV margins for IMRT and VMAT differed by less than 0.3 mm. Conclusion: VMAT-based SBRT for NSCLC was associated with significantly shorter delivery times and correspondingly smaller intrafraction motion compared with noncoplanar IMRT. However, the impact on the required PTV margin was small.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-J-137: Intrafractional Change of the Relationship Between Internal Fiducials and External Breathing Signal in Pancreatic Cancer Stereotactic Body Radiation Therapy

Purpose: The use of respiratory gating for management of breathing motion during stereotactic body radiation therapy (SBRT) relies on a consistent relationship between the breathing signal and the actual position of the internal target. This relationship was investigated in patients treated for pancreatic cancer. Methods: Four patients with pancreatic cancer undergoing SBRT that had implanted fiducials in the tumor were included in this study. Treatment plans were generated based on the exhale phases (30–70%) from the pre-treatment 4DCT. The margin between the internal target volume (ITV) and the planning target volume was three mm. After patient setup using cone-beam CT, simultaneous fluoroscopic imaging and breathing motion monitoring were used during at least three breathing cycles to verify the fiducial position and to optimize the gating window. After treatment, fluoroscopic images were acquired for verification purposes and exported for retrospective analyses. Fiducial positions were determined using a template-matching algorithm. For each dataset, we established a linear relationship between the fiducial position and the anterior-posterior (AP) breathing signal. The relationships before and after treatment were compared and the dose distribution impact evaluated. Results: Seven pre- and post-treatment fluoroscopic pairs were available for fiducial position analyses in the superior-inferior (SI) and left-right (LR) directions, and five in the AP direction. Time between image acquisitions was typically six to eight minutes. An average absolute change of 1.2±0.7 mm (range: 0.1–1.7) of the SI fiducial position relative to the external signal was found. Corresponding numbers for the LR and AP fiducial positions were 0.9±1.0 mm (range: 0.2–3.0) and 0.5±0.4 mm (range: 0.2–1.2), respectively. The dose distribution impact was small in both the ITV and organs-at-risk. Conclusion: The relationship change between fiducial position and external breathing signal has been observed to be about 1 mm in four pancreas SBRT patients, leading to small dose distribution impact. Pettersson and Cervino are funded by a Varian Medical Systems grant.

60 APPLIED LIFE SCIENCES↗

A Preliminary Feasibility Study on Multi-Cavity Cryomodule Integration for the Electron Ion Collider Energy Recover Linac Cooler

The Electron-Ion Collider (EIC) is a state-of-the-art accelerator designed for collisions between highly polarized electrons and ions. To achieve optimal luminosity, the ion beam is cooled using an electron beam sourced from an energy recovery linac (ERL). In the current ERL baseline design, one BNL type RF cavity is used per cryomodule, leading to spatial and cost challenges. This study examines the feasibility of using more compact PERLE (Powerful Energy Recovery Linac for Experiments) type cavities, which can house multiple cavities within a single cryomodule, by evaluating their Beam Breakup (BBU) instability performance. Higher Order Modes (HOM) parameters were obtained through frequency scaling, assuming constant quality factor Q_L, R/Q, and linearly scaling HOM frequencies. To predict the BBU threshold current and ensure accuracy, two different BBU tracking simulations are used for cross-verification. Although the reduced footprint of PERLE-type cavities is advantageous, maintaining sufficient damping of HOMs remains crucial. Finally, we compare the HOM damping efficiency of both cavity types and suggest a pathway forward.

Deitrick, K.↗

A Greenhouse-Gas Information System: Monitoring and Validating Emissions Reporting and Mitigation

This study and report focus on attributes of a greenhouse-gas information system (GHGIS) needed to support MRV&V needs. These needs set the function of such a system apart from scientific/research monitoring of GHGs and carbon-cycle systems, and include (not exclusively): the need for a GHGIS that is operational, as required for decision-support; the need for a system that meets specifications derived from imposed requirements; the need for rigorous calibration, verification, and validation (CV&V) standards, processes, and records for all measurement and modeling/data-inversion data; the need to develop and adopt an uncertainty-quantification (UQ) regimen for all measurement and modeling data; and the requirement that GHGIS products can be subjected to third-party questioning and scientific scrutiny. This report examines and assesses presently available capabilities that could contribute to a future GHGIS. These capabilities include sensors and measurement technologies; data analysis and data uncertainty quantification (UQ) practices and methods; and model-based data-inversion practices, methods, and their associated UQ. The report further examines the need for traceable calibration, verification, and validation processes and attached metadata; differences between present science-/research-oriented needs and those that would be required for an operational GHGIS; the development, operation, and maintenance of a GHGIS missions-operations center (GMOC); and the complex systems engineering and integration that would be required to develop, operate, and evolve a future GHGIS.

54 ENVIRONMENTAL SCIENCES↗

CASL Institutional Computing Report, CY2013 [Slides]

• FY14: Mini-PIRTs conducted on challenge problems to provide subject matter input on important physics models, experimental data, and figures of merit – Progression problem 6, CIPS, PCI – RIA and LOCA up next • Tailor “generic” VUQ plan (FY14 milestone) to each challenge problem – Appendix to challenge problem charters • FY15: Full implementation of probabilistic model calibration capability – Complete implementation of GPMSA in QUESO – Complete verification tests of sampling algorithms in QUESO – Complete Dakota-QUESO interface • FY15: Demonstrate dimension reduction capability for large input spaces – Hybrid sampling methods for ESM dimension reduction and probabilistic calibration.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SAM Code Development for Source Term Modeling in Fluoride-salt-cooled High-temperature Reactors

The SAM code is under development and supported by DOE-NE’s Nuclear Energy Advanced Modeling and Simulation program as a modern system-level modeling and simulation tool for advanced non-light water reactor safety analyses. These advanced reactor concepts incorporate novel and improved approaches to achieve safety and economic feasibility. Many concepts leverage higher operating temperatures for improved efficiency with a variety of coolants and structural materials to support those needs. Such design choices may also pose unique radiological source term risks. There are continuous efforts to incorporate new physics and phenomena relevant to advanced reactor concepts, including capabilities to enable system-level source term modeling. The Pebble-Bed Fluoride-salt-cooled High-temperature Reactor (PB-FHR) is a promising candidate among advanced nuclear reactor concepts with its improved passive safety characteristics and high thermal efficiency. In addition to past efforts to support the development and utilization of SAM for PB-FHR safety analysis, the species transport modeling capabilities in SAM have been extended to simulate source term phenomena in concepts like the PB-FHR. The PB-FHR concept utilizes pebble-form TRISO fuel and FLiBe salt coolant to provide robust barriers to the release of almost all fission products and radiological source terms. However, tritium poses a unique radiological risk due to its significant production from neutron interactions with 6 Li and 9 Be in the FLiBe as well as its high mobility at elevated temperatures where it can permeate through structural metals. Secondly, the use of graphite at elevated temperatures poses the risk of oxidation damage to any structural components or fuel pebbles that are exposed to accidental air ingress. This report summarizes progress made in modeling these phenomena in SAM, which leverages the system-level multi-physics thermal hydraulic simulation to support an effective engineering-scale source term modeling capability. A tritium transport model is developed to simulate the various transport pathways in FHR and MSR concepts and is presented through verification and validation examples as well as demonstrations simulating experimental test loops and reference plant FHR models. A graphite oxidation model is also introduced to calculate local oxidation rates and is presented with initial validation results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Validation of Weather Forecasting Products

Meteorological modeling plays a pivotal role in operational safety and emergency response at the Savannah River Site (SRS). This study focuses on verifying the Regional Atmospheric Modelling System (RAMS) Version 4.3 through Mean Bias Error (MBE) and Root Mean Square Error (RMSE) analyses of temperature, dew point, and wind speed over a decade. Using observed data from SRS, we assessed RAMS' accuracy, revealing seasonal biases and error trends. Results indicate RAMS' strengths in mild weather conditions but challenges during seasonal extremes and wind speed predictions due to measurement disparities. Future research aims to expand verification to other models and parameters, advocating for enhanced forecasting accuracy crucial for safeguarding personnel and community well-being.

42 ENGINEERING↗

Space Geodesy and Geochemistry Applied to the Monitoring, Verification of Carbon Capture and Storage

This award was a training grant awarded by the U.S. Department of Energy (DOE). The purpose of this award was solely to provide training for two PhD graduate students for three years in the general area of carbon capture and storage (CCS). The training consisted of course work and conducting research in the area of CCS. Attendance at conferences was also encouraged as an activity and positive experience for students to learn the process of sharing research findings with the scientific community, and the peer review process. At the time of this report, both students have approximately two years remaining of their studies, so have not fully completed their scientific research projects.

54 ENVIRONMENTAL SCIENCES↗

On the Verification of Deep Reinforcement Learning Solution for Intelligent Operation of Distribution Grids

Capabilities of deep reinforcement learning (DRL) in obtaining fast decision policies in high dimensional and stochastic environments have led to its extensive use in operational research, including the operation of distribution grids with high penetration of distributed energy resources (DER). However, the feasibility and robustness of DRL solutions are not guaranteed for the system operator, and hence, those solutions may be of limited practical value. This paper proposes an analytical method to find feasibility ellipsoids that represent the range of multi-dimensional system states in which the DRL solution is guaranteed to be feasible. Empirical studies and stochastic sampling determine the ratio of the discovered to the actual feasible space as a function of the sample size. In addition, the performance of logarithmic, linear, and exponential penalization of infeasibility during the DRL training are studied and compared in order to reduce the number of infeasible solutions

Hosseini, Mohammad Mehdi↗

Multi-System Verification of Registrations for Image-Guided Radiotherapy in Clinical Trials

Purpose: To provide quantitative information on the image registration differences from multiple systems for image-guided radiotherapy (IGRT) credentialing and margin reduction in clinical trials. Methods and Materials: Images and IGRT shift results from three different treatment systems (Tomotherapy Hi-Art, Elekta Synergy, Varian Trilogy) have been sent from various institutions to the Image-Guided Therapy QA Center (ITC) for evaluation for the Radiation Therapy Oncology Group (RTOG) trials. Nine patient datasets (five head-and-neck and four prostate) were included in the comparison, with each patient having 1-4 daily individual IGRT studies. In all cases, daily shifts were re-calculated by re-registration of the planning CT with the daily IGRT data using three independent software systems (MIMvista, FocalSim, VelocityAI). Automatic fusion was used in all calculations. The results were compared with those submitted from institutions. Similar regions of interest (ROIs) and same initial positions were used in registrations for inter-system comparison. Different slice spacings for CBCT sampling and different ROIs for registration were used in some cases to observe the variation of registration due to these factors. Results: For the 54 comparisons with head-and-neck datasets, the absolute values of differences of the registration results between different systems were 2.6 {+-} 2.1 mm (mean {+-} SD; range 0.1-8.6 mm, left-right [LR]), 1.7 {+-} 1.3 mm (0.0-4.9 mm, superior-inferior [SI]), and 1.8 {+-} 1.1 mm (0.1-4.0 mm, anterior-posterior [AP]). For the 66 comparisons in prostate cases, the differences were 1.1 {+-} 1.0 mm (0.0-4.6 mm, LR), 2.1 {+-} 1.7 mm (0.0-6.6 mm, SI), and 2.0 {+-} 1.8 mm (0.1-6.9 mm, AP). The differences caused by the slice spacing variation were relatively small, and the different ROI selections in FocalSim and MIMvista also had limited impact. Conclusion: The extent of differences was reported when different systems were used for image registration. Careful examination and quality assurance of the image registration process are crucial before considering margin reduction using IGRT in clinical trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A synthetic diamond diode in volumetric modulated arc therapy dosimetry

Purpose: The aim of this work is to investigate the behavior of a single crystal diamond diode (SCDD) for volumetric modulated arc therapy (VMAT) dose verifications. This delivery technique is one of the most severe test of a dosimeter performance due to the modulation of the dose rate achieved by simultaneously changing the velocity of the gantry and the position of the collimator leaves. The performed measurements with VMAT photon beams can therefore contribute to an overall global validation of the device to be used in dose distribution verifications.Methods: The SCDD response to 6 MVRX has been tested and compared with reference ionization chambers and treatment planning system (TPS) calculations in different experiments: (a) measurements of output factors for small field sizes (square fields of side ranging between 8 mm and 104 mm) by SCDD and A1SL ionization chamber; (b) angular dependence evaluation of the entire experimental set-up by SCDD, A1SL, and Farmer ionization chambers; and (c) acquisition of dose profiles for a VMAT treatment of a pulmonary disease in latero-lateral and gantry-target directions by SCDD and A1SL ionization chamber.Results: The output factors measured by SCDD favorably compare with the ones obtained by A1SL, whose response is affected by the lack of charged particle equilibrium and by averaging effect when small fields are involved. From the experiment on angular dependence, a good agreement is observed among the diamond diode, the ion chambers, and the TPS. In VMAT profiles, the absorbed doses measured by SCDD and A1SL compare well with the TPS calculated ones. An overall better agreement is observed in the case of the diamond dosimeter, which is also showing a better accuracy in terms of distance to agreement in the high gradient regions.Conclusions: Synthetic diamond diodes, whose performance were previously studied for conformal and IMRT radiotherapy techniques, were found to be suitable detectors also for dosimetric measurements in volumetric arc therapy treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ITER Central Solenoid Coil Insulation Qualification

An insulation system for ITER Central Solenoid must have sufficiently high electrical and structural strength. Design efforts to bring stresses in the turn and layer insulation within allowables failed. It turned out to be impossible to eliminate high local tensile stresses in the winding pack. When high local stresses can not be designed out, the qualification procedure requires verification of the acceptable structural and electrical strength by testing. We built two 4x4 arrays of the conductor jacket with two options of the CS insulation and subjected the arrays to 1.2 million compressive cycles at 60 MPa and at 76 K. Such conditions simulated stresses in the CS insulation. We performed voltage withstand tests and after end of cycling we measured the breakdown voltages between in the arrays. After that we dissectioned the arrays and studied micro cracks in the insulation. We report details of the specimens’ preparation, test procedures and test results.

Applied↗