Search NASA⌕ Search

SEARCH · Search NASA

Results for “activation volume”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Response of local vascular volumes to lower body negative pressure stress

The present study involved an intravenous injection of radioactive iodinated serum albumin, equilibration of this isotope within the vascular space, and the continuous measurement of isotope activity over selected anatomical areas before, during and following multiple human LBNP tests. Both rate and magnitude of vascular pooling were distinctly different within each of five selected lower body anatomical areas. In the upper body, all areas except the abdomen showed depletions from their resting vascular volumes during LBNP. The presence of uniquely different pooling patterns in the lower body, the apparent stability of abdominal vascular volumes, and a possible decrease in cerebral blood volume during LBNP represent the major findings of this study.

Wolthuis, R. A.↗

Magnetic Resonance Imaging-Based Radiation-Absorbed Dose Estimation of {sup 166}Ho Microspheres in Liver Radioembolization

Purpose: To investigate the potential of magnetic resonance imaging (MRI) for accurate assessment of the three-dimensional {sup 166}Ho activity distribution to estimate radiation-absorbed dose distributions in {sup 166}Ho-loaded poly (L-lactic acid) microsphere ({sup 166}Ho-PLLA-MS) liver radioembolization. Methods and Materials: MRI, computed tomography (CT), and single photon emission CT (SPECT) experiments were conducted on an anthropomorphic gel phantom with tumor-simulating gel samples and on an excised human tumor-bearing liver, both containing known amounts of {sup 166}Ho-PLLA-MS. Three-dimensional radiation-absorbed dose distributions were estimated at the voxel level by convolving the {sup 166}Ho activity distribution, derived from quantitative MRI data, with a {sup 166}Ho dose point-kernel generated by MCNP (Monte Carlo N-Particle transport code) and from Medical Internal Radiation Dose Pamphlet 17. MRI-based radiation-absorbed dose distributions were qualitatively compared with CT and autoradiography images and quantitatively compared with SPECT-based dose distributions. Both MRI- and SPECT-based activity estimations were validated against dose calibrator measurements. Results: Evaluation on an anthropomorphic phantom showed that MRI enables accurate assessment of local {sup 166}Ho-PLLA-MS mass and activity distributions, as supported by a regression coefficient of 1.05 and a correlation coefficient of 0.99, relating local MRI-based mass and activity calculations to reference values obtained with a dose calibrator. Estimated MRI-based radiation-absorbed dose distributions of {sup 166}Ho-PLLA-MS in an ex vivo human liver visually showed high correspondence to SPECT-based radiation-absorbed dose distributions. Quantitative analysis revealed that the differences in local and total amounts of {sup 166}Ho-PLLA-MS estimated by MRI, SPECT, and the dose calibrator were within 10%. Excellent agreement was observed between MRI- and SPECT-based dose-volume histograms. Conclusions: Quantitative MRI was demonstrated to provide accurate three-dimensional {sup 166}Ho-PLLA-MS activity distributions, enabling localized intrahepatic radiation-absorbed dose estimation by convolution with a {sup 166}Ho dose point-kernel for liver radioembolization treatment optimization and evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Conceptual Design of DUNE Near Detector Superconducting Magnet System

The Deep Underground Neutrino Experiment (DUNE) has formed a near detector design group (NDDG) tasked with delivering a CDR by the end of 2019. The DUNE Near Detectors will be housed in an underground hall on the Fermilab site. The two main detector systems are a liquid argon detector and a high-pressure gas time projection chamber (HPgTPC). The HPgTPC requires a magnet that generates a 0.5 T solenoidal magnetic field in a large volume of 6 m diameter, and 5 m length. Herein, we present a superconducting magnet system design. We investigated: an open air core magnet with three coils, and a five coils system having two active fringe field shielding coils. Coils positions were optimized to obtain the specified field homogeneity in the magnet good field region, while minimizing the Lorentz forces and the superconductor volume. We discuss the magnetic, mechanical, and thermal conceptual designs.

43 PARTICLE ACCELERATORS↗

Inhibition of HMGB1 mediates neuroprotection of traumatic brain injury by modulating the microglia/macrophage polarization

Highlights: • Treatment with GL could improve the neurological function recovery and reduce the lesion volume after TBI. • Administration of GL could inhibit the release and expression of HMGB1. • Treatment with GL could inhibit M1 phenotype while promoted M2 phenotype activation of microglia/macrophages after TBI. Microglia/Macrophages have a double-edged role in secondary brain damage after traumatic brain injury (TBI) depending on polarization toward proinflammatory M1 or anti-inflammatory M2 phenotypes. Recently, high-mobility group box 1 (HMGB1) was found to influence the polarization of macrophages. In this study, glycyrrhizin (GL), an inhibitor of HMGB1, was used to investigate whether the inhibition of HMGB1 could modulate microglia/macrophage polarization after TBI. The results showed that treatment with GL improved the neurological function recovery, reduced the lesion volume, and inhibited the release and expression of HMGB1 after TBI. In addition, the administration of GL suppressed M1 phenotype activation and promoted M2 phenotype activation of microglia/macrophages. In conclusion, the results suggested that GL attenuated TBI by inhibiting M1 phenotype while inducing M2 phenotype activation of microglia/macrophages, at least partly through inhibiting HMGB1. Also, targeting HMGB1 to modulate the microglia/macrophage polarization should be one potential therapeutic approach for TBI.

60 APPLIED LIFE SCIENCES↗

Breaking the Energy Barrier of Heavy Metal Ion Diffusion in Micropores with Mesoporous 3D Graphene for Fast and Efficient Cu2+ Removal

Efficient removal of heavy metals from water critically depends not only on adsorption capacity but also on ion diffusion kinetics and the associated energy barriers. In conventional carbon adsorbents, severe diffusion confinement within micropores restricts ion transport, resulting in sluggish adsorption kinetics and large apparent activation energies despite high specific surface areas. Here, we demonstrate that this fundamental limitation is overcome by engineering meso/macroporous architectures in the 3D graphene materials synthesized via our discovered alkali-metal reactions with\\\\r\\\\n2\\\\r\\\\nCO. The unique 3D graphene materials possess defect-rich graphene frameworks with interconnected meso/macroporous networks, exhibiting simultaneously high surface area and greatly enhanced meso/macropore volume that enable efficient access to adsorption sites. As a result, the Cu2+ adsorption on 3D graphene proceeds with very low activation energies (4.98 kJ mol–1), which is almost 4 times smaller than on activated carbon (23.1 kJ mol–1). This finding offers a promising platform for efficient and sustainable water purification.

25 ENERGY STORAGE↗

Tumor Delineation Based on Time-Activity Curve Differences Assessed With Dynamic Fluorodeoxyglucose Positron Emission Tomography-Computed Tomography in Rectal Cancer Patients

Purpose: To develop an unsupervised tumor delineation method based on time-activity curve (TAC) shape differences between tumor tissue and healthy tissue and to compare the resulting contour with the two tumor contouring methods mostly used nowadays. Methods and Materials: Dynamic positron emission tomography-computed tomography (PET-CT) acquisition was performed for 60 min starting directly after fluorodeoxyglucose (FDG) injection. After acquisition and reconstruction, the data were filtered to attenuate noise. Correction for tissue motion during acquisition was applied. For tumor delineation, the TAC slope values were k-means clustered into two clusters. The resulting tumor contour (Contour I) was compared with a contour manually drawn by the radiation oncologist (Contour II) and a contour generated using a threshold of the maximum standardized uptake value (SUV; Contour III). Results: The tumor volumes of Contours II and III were significantly larger than the tumor volumes of Contour I, with both Contours II and III containing many voxels showing flat TACs at low activities. However, in some cases, Contour II did not cover all voxels showing upward TACs. Conclusion: Both automated SUV contouring and manual tumor delineation possibly incorrectly assign healthy tissue, showing flat TACs, as being malignant. On the other hand, in some cases the manually drawn tumor contours do not cover all voxels showing steep upward TACs, suspected to be malignant. Further research should be conducted to validate the possible superiority of tumor delineation based on dynamic PET analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-402: Y-90 Microspheres (SIR Spheres) for Treatment of Liver Metastasis : Technique

Purpose: The purpose of this presentation is to discuss the radiation safety and dosimetric technique used for the therapeutic procedure using Y-90 microspheres through intra -arterial administration on patients with liver metastasis Methods: The radiation dosimetry, technique and safety aspects of 14 patients with primary and metastatic liver cancer, treated with Y-90 microsphere (SIR spheres) are discussed. The liver and tumor volumes were determined using the CT and MR scans . The images were imported into the treatment planning system and the liver and tumor volumes and the volume of the liver affected were outlined and the volume calculation was performed using the software. The lung shunt fraction (LSF) and tumor to liver uptake ratio (TLR) were determined using the nuclear medicine SPECT imaging with Tc-99m MAA. The absorbed dose to the target volume in liver was calculated using the following equation:Dose ? (Gy) = C x E? x 5.92 x 10-6 (Gy/s) x T(1/2)(days) x 1.44 x 8.64 x 104 (s) The distribution of activity in the tumor bed was confirmed by post Y-90 administration imaging using the Bremsstrahlung peak at 30% window. The patient and the procedure room were surveyed and radiation safety instructions were given to the patient Results: The tumor volume ranged from 77 cc to 700 cc, tumor to liver uptake ranged from 3 to 12. The lung shunt fraction varied from 1.08% to 9.0%. The activity administered ranged from 1.0GBq to 2.5 GBq, . The radiation survey in contact with the patient ranged from 1.8 mR/hr to 2.5 mR/hr and reading at 1 meter was less than 0.2 mR/hr Conclusion: The technique for radiation dosimetry and radiation safety for Y-90 microsphere therapy is established. The post treatment imaging helped to confirm the distribution of Y-90 microspheres inside the tumor bed.

60 APPLIED LIFE SCIENCES↗

Reconciling Contrasting Relationships Between Relative Dispersion and Volume-Mean Radius of Cloud Droplet Size Distributions

Cloud droplet spectral relative dispersion is critical to parameterizations of cloud radiative properties, warm-rain initiation, and aerosol-cloud interactions in models; however, there is no consistent relationship between relative dispersion and volume-mean radius in literature, which hinders improving relative dispersion parameterization and calls for physical explanation. Here we show, by analyzing aircraft observations of cumulus clouds during Routine AAF [Atmospheric Radiation Measurement (ARM) Aerial Facility] Clouds with Low Optical Water Depths (CLOWD) Optical Radiative Observations, that the correlation between relative dispersion and volume-mean radius changes from positive to negative as volume-mean radius increases. With the new observation, we postulate that the sign of the correlation is determined by whether or not condensation (evaporation) occurs simultaneously with significant new activation (deactivation). The hypothesis is validated by simulations of both an adiabatic cloud parcel model and a parcel model accounting for entrainment-mixing. A new quantity, first bin strength, is introduced to quantify this new observation. Theoretical analysis of truncated gamma and modified gamma size distributions further supports the hypothesis and reconciles the contrasting relationships between relative dispersion and volume-mean radius, including the results in polluted fog observations. The results could shed new light on the so-called “twilight zone” between cloudy and cloud-free air, which in turn affects evaluation of aerosol-cloud interactions and retrieval of aerosol optical depth.

Lu, Chunsong↗

Characterizing Interference in Radio Astronomy Observations through Active and Unsupervised Learning

In the process of observing signals from astronomical sources, radio astronomers must mitigate the effects of manmade radio sources such as cell phones, satellites, aircraft, and observatory equipment. Radio frequency interference (RFI) often occurs as short bursts (< 1 ms) across a broad range of frequencies, and can be confused with signals from sources of interest such as pulsars. With ever-increasing volumes of data being produced by observatories, automated strategies are required to detect, classify, and characterize these short "transient" RFI events. We investigate an active learning approach in which an astronomer labels events that are most confusing to a classifier, minimizing the human effort required for classification. We also explore the use of unsupervised clustering techniques, which automatically group events into classes without user input. We apply these techniques to data from the Parkes Multibeam Pulsar Survey to characterize several million detected RFI events from over a thousand hours of observation.

Doran, G.↗

Effect of intermittent standing and walking on physiological changes induced by head-down bed rest

Continuous exposure to gravity may not be necessary to prevent compromised physiological function resulting from exposure to microgravity. However, minimum gravity (G) exposure requirements, effectiveness of passive Gz versus activity in a G field, and optimal G stimulus amplitude, duration, and frequency are unknown. To partially address these questions, a 4-day, 6 degree head-down bed rest (HDBR) study (one ambulatory control day, 4 full HDBR days, one recovery day) was conducted. Nine males, 30-50 yr, were subjected to four different +1 Gz (head-foot) exposure protocols (periodic standing or controlled walking for 2 or 4 h/day in 15 min doses), plus a continuous HDBR (0 Gz) control. Standing 4 h completely prevented and standing 2 h partially prevented post-HDBR orthostatic intolerance. Both walking conditions (2 h and 4 h) attenuated the decrease in peak VO2 and prevented the increased urinary Ca2+ excretion associated with HDBR. Both 4 h conditions (standing and walking) attenuated plasma volume loss during HDBR. It was concluded that various physiological systems benefit differentially from passive +1 Gz or activity in +1 Gz and the duration (2 h vs. 4 h) of the stimulus may be an important moderating factor.

Vernikos, J.↗

Ionic-content-driven restructuring of spirobisindane ionene networks: implications for mechanics, self-healing, and gas transport

Polymers of intrinsic microporosity (PIMs) offer exceptional gas permeability but remain brittle and susceptible to physical aging, limiting their durability in separation applications. Here, we introduce a reconfigurable microporous polymer network that uniquely integrates permanent PIM microporosity with autonomous, intrinsic self-healing driven by imidazolium-based ionic motifs. Spirobisindane units generate the intrinsic free-volume architecture, while an imidazolium-containing polyamide ionene supplies dynamic ionic and hydrogen-bonding interactions that reorganize under mild activation. Incorporation of imidazolium-based ionic liquids further tunes cohesion, mobility, and densification, enabling the network to relax, re-associate, and retain microporosity without structural collapse. Through a comprehensive multiscale approach combining spectroscopy, scattering, thermal and mechanical characterization with all-atom molecular dynamics and density functional theory calculations, we elucidate how ionic content, as a single control parameter that reshapes free-volume distributions, modulates local coordination environments, and governs relaxation and healing kinetics. At intermediate ionic loadings, the networks achieve rapid, repeatable self-healing while maintaining CO$_2$ selectivity, demonstrating an optimal balance between segmental mobility and structural integrity. By establishing how hierarchical ionic interactions couple structure, dynamics, and transport in microporous ionene networks, this work provides generalizable design rules for adaptive soft-matter systems that require simultaneous mechanical resilience, reconfigurability, and selective gas transport.

36 MATERIALS SCIENCE↗

Scalable Preparation of Ternary Hierarchical Silicon Oxide-Nickel-Graphite Composites for Lithium-Ion Batteries

Silicon monoxide is a promising anode candidate because of its high theoretical capacity and good cycle performance. To solve the problems associated with this material, including large volume changes during charge-discharge processes, we report a ternary hierarchical silicon oxide–nickel–graphite composite prepared by a facile two-step ball-milling method. The composite consists of nano-Si dispersed silicon oxides embedded in nano-Ni/graphite matrices (Si@SiOx/Ni/graphite). In the composite, crystalline nano-Si particles are generated by the mechanochemical reduction of SiO by ball milling with Ni. These nano-Si dispersed oxides have abundant electrochemical activity and can provide high Li-ion storage capacity. Furthermore, the milled nano-Ni/graphite matrices stick well to active materials and interconnect to form a crosslinked framework, which functions as an electrical highway and a mechanical backbone so that all silicon oxide particles become electrochemically active. Owing to these advanced structural and electrochemical characteristics, the composite enhances the utilization efficiency of SiO, accommodates its large volume expansion upon cycling, and has good ionic and electronic conductivity. The composite electrodes thus exhibit substantial improvements in electrochemical performance. This ternary hierarchical Si@SiOx/Ni/graphite composite is a promising candidate anode material for high-energy lithium-ion batteries. Additionally, the mechanochemical ball-milling method is low cost and easy to reproduce, indicating potential for the commercial production of the composite materials.

25 ENERGY STORAGE↗

Temporal-spatial analysis of U.S.-Mexico border environmental fine and coarse PM air sample extract activity in human bronchial epithelial cells

Particulate matter less than 10 {mu}m (PM10) has been shown to be associated with aggravation of asthma and respiratory and cardiopulmonary morbidity. There is also great interest in the potential health effects of PM2.5. Particulate matter (PM) varies in composition both spatially and temporally depending on the source, location and seasonal condition. El Paso County which lies in the Paso del Norte airshed is a unique location to study ambient air pollution due to three major points: the geological land formation, the relatively large population and the various sources of PM. In this study, dichotomous filters were collected from various sites in El Paso County every 7 days for a period of 1 year. The sampling sites were both distant and near border crossings, which are near heavily populated areas with high traffic volume. Fine (PM2.5) and Coarse (PM10-2.5) PM filter samples were extracted using dichloromethane and were assessed for biologic activity and polycyclic aromatic (PAH) content. Three sets of marker genes human BEAS2B bronchial epithelial cells were utilized to assess the effects of airborne PAHs on biologic activities associated with specific biological pathways associated with airway diseases. These pathways included in inflammatory cytokine production (IL-6, IL-8), oxidative stress (HMOX-1, NQO-1, ALDH3A1, AKR1C1), and aryl hydrocarbon receptor (AhR)-dependent signaling (CYP1A1). Results demonstrated interesting temporal and spatial patterns of gene induction for all pathways, particularly those associated with oxidative stress, and significant differences in the PAHs detected in the PM10-2.5 and PM2.5 fractions. Temporally, the greatest effects on gene induction were observed in winter months, which appeared to correlate with inversions that are common in the air basin. Spatially, the greatest gene expression increases were seen in extracts collected from the central most areas of El Paso which are also closest to highways and border crossings.

60 APPLIED LIFE SCIENCES↗

Evaluation of Cavity Collapse and Surface Crater Formation for Selected Lawrence Livermore National Laboratory Underground Nuclear Tests - 2010

This report evaluates collapse evolution for selected Lawrence Livermore National Laboratory (LLNL) underground nuclear tests at the Nevada National Security Site (NNSS, formerly called the Nevada Test Site). The work is being done at the request of Navarro-Interra LLC, and supports environmental restoration efforts by the Department of Energy, National Nuclear Security Administration for the Nevada Site Office. Safety decisions must be made before a surface crater area, or potential surface crater area, can be reentered for any work. Our statements on cavity collapse and surface crater formation are input into their safety decisions. These statements do not include the effects of erosion that may modify the surface collapse craters over time. They also do not address possible radiation dangers that may be present. Subject matter experts from the LLNL Containment Program who had been active in weapons testing activities performed these evaluations. Information used included drilling and hole construction, emplacement and stemming, timing and sequence of the selected test and nearby tests, geology, yield, depth of burial, collapse times, surface crater sizes, cavity and crater volume estimations, and ground motion. Both classified and unclassified data were reviewed. Various amounts of information are available for these tests, depending on their age and other associated activities. Lack of data can hamper evaluations and introduce uncertainty. We make no attempt to quantify this uncertainty.

54 ENVIRONMENTAL SCIENCES↗

FIRST THREE-DIMENSIONAL RECONSTRUCTIONS OF CORONAL LOOPS WITH THE STEREO A+B SPACECRAFT. III. INSTANT STEREOSCOPIC TOMOGRAPHY OF ACTIVE REGIONS

Here we develop a novel three-dimensional (3D) reconstruction method of the coronal plasma of an active region by combining stereoscopic triangulation of loops with density and temperature modeling of coronal loops with a filling factor equivalent to tomographic volume rendering. Because this method requires only a stereoscopic image pair in multiple temperature filters, which are sampled within {approx}1 minute with the recent STEREO/EUVI instrument, this method is about four orders of magnitude faster than conventional solar rotation-based tomography. We reconstruct the 3D density and temperature distribution of active region NOAA 10955 by stereoscopic triangulation of 70 loops, which are used as a skeleton for a 3D field interpolation of some 7000 loop components, leading to a 3D model that reproduces the observed fluxes in each stereoscopic image pair with an accuracy of a few percents (of the average flux) in each pixel. With the stereoscopic tomography we infer also a differential emission measure distribution over the entire temperature range of T {approx} 10{sup 4}-10{sup 7}, with predictions for the transition region and hotter corona in soft X-rays. The tomographic 3D model provides also large statistics of physical parameters. We find that the extreme-ultraviolet loops with apex temperatures of T{sub m} {approx}< 3.0 MK tend to be super-hydrostatic, while hotter loops with T{sub m} {approx} 4-7 MK are near-hydrostatic. The new 3D reconstruction model is fully independent of any magnetic field data and is promising for future tests of theoretical magnetic field models and coronal heating models.

99 GENERAL AND MISCELLANEOUS↗

Characterizing Interference in Radio Astronomy Observations through Active and Unsupervised Learning

In the process of observing signals from astronomical sources, radio astronomers must mitigate the effects of man-made radio sources such as cell phones, satellites, aircraft, and observatory equipment. Radio frequency interference (RFI) often occurs as short bursts (< 1 ms) across a broad range of frequencies, and can be confused with signals from sources of interest such as pulsars. With ever-increasing volumes of data being produced by observatories, automated strategies are required to detect, classify, and characterize these short “transient” RFI events. We investigate an active learning approach in which an astronomer labels events that are most confusing to a classifier, minimizing the human effort required for classification. We also explore the use of unsupervised clustering techniques, which automatically group events into classes without user input. We apply these techniques to data from the Parkes Multibeam Pulsar Survey to characterize several million detected RFI events from over a thousand hours of observation

Doran, G.↗

Image processing of multiphase images obtained via X-ray microtomography: A review

Easier access to X-ray microtomography (μCT) facilities has provided much new insight from high-resolution imaging for various problems in porous media research. Pore space analysis with respect to functional properties usually requires segmentation of the intensity data into different classes. Image segmentation is a nontrivial problem that may have a profound impact on all subsequent image analyses. This review deals with two issues that are neglected in most of the recent studies on image segmentation: (i) focus on multiclass segmentation and (ii) detailed descriptions as to why a specific method may fail together with strategies for preventing the failure by applying suitable image enhancement prior to segmentation. In this way, the presented algorithms become very robust and are less prone to operator bias. Three different test images are examined: a synthetic image with ground-truth information, a synchrotron image of precision beads with three different fluids residing in the pore space, and a μCT image of a soil sample containing macropores, rocks, organic matter, and the soil matrix. Image blur is identified as the major cause for poor segmentation results. Other impairments of the raw data like noise, ring artifacts, and intensity variation can be removed with current image enhancement methods. Bayesian Markov random field segmentation, watershed segmentation, and converging active contours are well suited for multiclass segmentation, yet with different success to correct for partial volume effects and conserve small image features simultaneously.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Caudate Lobe: The Blind Spot in Radioembolization or an Overlooked Opportunity?

PurposeThe caudate lobe (CL) is impartial to the functional left and right hemi-liver and has outspoken inter-individual differences in arterial vascularization. Unfortunately, this complexity is not specifically taken into account during radioembolization treatment (RE), potentially resulting in under- or overtreatment of the CL. The objective of this study was to evaluate the CL coverage in RE and determine the detection rate of the CL arteries on CT angiography during work-up.MethodsIn all consecutive patients who underwent RE treatment between May 2012–January 2015, {sup 99m}Tc-MAA SPECT/CT and posttreatment scans ({sup 90}Y-bremsstrahlung SPECT/CT, {sup 90}Y-PET/CT, or {sup 166}Ho-SPECT/CT) were reviewed for activity in the CL. Pretreatment CT angiographies were reviewed for the visibility of the CL arteries.ResultsEighty-two patients were treated. In 32/82 (39 %) the CL was involved. In 6/32 (19 %) patients, no activity was seen on the posttreatment scan in the CL, whereas in 40/50 (80 %) patients without CL tumor involvement, the CL was treated. {sup 99m}Tc-MAA SPECT/CT and final posttreatment scans were discordant in 16/78 (21 %). {sup 99m}Tc-MAA SPECT/CT had a positive and negative predictive value of 94 % and 46 %, respectively, for activity in the CL after RE. In untreated CLs, significant hypertrophy was observed with a median volume increase of 33 % (p = 0.02). CL arteries were seldom visible on the pretreatment CT; the identification rate was 12–17 %.ConclusionCurrently in RE treatments, targeting or sparing of the CL is highly erratic and independent of tumor involvement. Intentional treatment or bypassing of the CL seems worthwhile to either improve tumor coverage or enhance the functional liver remnant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗