Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Critical Current Stability of 2G REBCO Tape for Space-Flight HTS Leads

High reliability is an essential requirement for all spaceflight hardware. XRISM, a follow-on mission to the Hitomi x-ray observatory, also uses 2G REBCO tapes as current leads for the superconducting magnets that are a key component of the Adiabatic Demagnetization Refrigerator (ADR) that cools the detector array. While the Hitomi Soft X-ray Spectrometer (SXS) worked flawlessly in orbit, during its development there were indications that the critical current of its specialized REBCO tapes could degrade over time when exposed to normal-humidity air. To demonstrate that the updates to the XRISM HTS lead assemblies had mitigated this risk, a series of tests were carried out to measure the stability of Ic of dozens of samples over a period greater than the flight assemblies were exposed to air during integration and test. The test rig allowed not only the measurement of the sample Ic, but also the localization of the voltage rise as the current approached Ic. We will discuss the trends in the critical current of the samples, as well as localization of lower Ic regions.

Edgar R. Canavan↗

Thermal links and position resolution in multi-absorber hydra microcalorimeters

The “hydra” style of position-sensitive, multi-absorber microcalorimeter is used in some imaging x-ray spectroscopy detector arrays to thermally multiplex multiple pixels to one sensor, thereby enabling readout of larger arrays for a given number of sensor readout channels. We describe the benefit of choosing a set of thermal conductance values for the links between absorbers and sensor such that the probability of misidentifying the absorber hit location is minimized while still achieving a specified x-ray energy resolution for all pixels. We illustrate the benefit of this approach as applied in our current prototype 25-pixel hydra magnetic microcalorimeter arrays for the Lynx x-ray astrophysics mission concept.

microcalorimeter↗

Development of Concurrent Artificially-Intelligent Spectrometry and Adaptive Lidar System (CASALS) for Swath Mapping From Space

We present the design and performance of a Concurrent Artificially-intelligent Spectrometry and Adaptive Lidar System (CASALS) for 3D imaging from Space. With a single fast wavelength tuning laser, CASALS accomplishes a 1,200 resolvable spots swath mapping by grating dispersion wavelength steering. Any subset of these 1,200 spots can be selected by wavelength switching. The validation operating principle was accomplished and reported in IGASS-2022. With configurable base design, we report the designs and progress of the CASALS airplane campaign with 256 contiguous ground spots. It is accomplished with a single fast tuning lase at 1040-nm, 1.152MHz tuning rate, and pulse modulated 2-ns on each wavelength. Return pulses are mapped to an eight-pixel detector array with single-photon sensitivity. The lidar returns are time-multiplexed to two outputs that are digitized with two 1-GSPS-digitizer. A grating spectrometer rejects solar background noise spatially and spectrally. We are developing a 1040-nm CASALS intended for multiple LEO orbit missions: Earth Venture Mission on ESPA Grande, STV Mission on ESPA Grande SmallSat, STV Mission on spacecraft equivalent to ICESat power (SWaP,) and splitting the laser beam requires higher laser pulse energy.

ranging lidar↗

Development of a Generic Small-Satellite Payload for On-Orbit Characterization and Evaluation of Novel Radiation-Shielding Materials

There is a need for lightweight and novel radiation shielding for small satellites operating in LEO and beyond. Current state of the art shielding materials include aluminum and polyethylene, or no shielding due to weight and dimensional considerations. New materials are being developed which may offer advantages over current options. These materials include novel lightweight composites impregnated with metallic nanoparticles, chitin-derived bioplastics, and aerogel-family materials. A compact experiment platform that allows the simultaneous testing of a number of potential shielding materials will be useful in comparing and validating them. The effort now underway seeks to develop a miniaturized, modularized payload which will allow testing of materials using 1U CubeSat form factor modules with four scintillator radiation detectors arrayed behind four sample material windows exposed to space. The first proposed mission will utilize a 2U payload volume to host two test quartets enabling eight materials to be tested. Such a test platform can potentially be used as a hosted payload on a variety of spacecraft to test other materials in the future.

Avery D Brock↗

CODEX Optical Design and Alignment

The COronal Diagnostic EXperiment (CODEX) is a Heliophysics mission to measure the density, temperature, and velocity of the electrons in the solar corona with the primary goal of improving our understanding of the physical conditions of the solar wind in the acceleration region. The temperature and velocity measurement requires much higher signal-to-noise ratio than the density measurements. In solar coronagraphs, the diffraction of the solar disk light due to the occulting element is the dominant source of noise. Therefore, to further suppress the diffracted sun light with respect to the existing coronagraphs is a critical element of the CODEX design. To minimize the stray light due to diffraction, the selected optical design is a two-stage standard coronagraph with an external occulter, an internal occulter, and a Lyot stop. What is unique for this design is that a focal mask was inserted at the telescope focal plane. It works together with the field lens suppressing the stray light down by ~ another order of magnitude as compared to a traditional three-stage approach. During the optical design, a Fourier Transform based beam propagation software, i.e., GLAD, was used to model the beam path through the full coronagraph, from the external occulter to the detector array. All diffraction sensitive elements: external occulter, internal occulter, focal mask, and Lyot stop were carefully modeled and optimized. As a result, the requirement of achieving a stray light level which is one order of magnitude lower than F-corona was satisfied. On the other hand, to achieve the final suppression, a precision optical alignment is another must. This paper also presents our creative alignment procedure: using the combination of metrology, precision alignment equipment, and real time diffraction ring monitoring to minimize the diffraction. The final test results show that the suppression ratio (B/B 0 ) reaches 10 -11 level, which is equivalent to one order of magnitude lower than F-corona.

CODEX optical design and alignment↗

Development of a Universal Small-Satellite Payload for On-Orbit Characterization and Evaluation of Novel Radiation-Shielding Materials

There is a need for novel lightweight radiation shielding materials for small satellites operating in LEO and beyond. Current commonly used shielding materials include aluminum and polyethylene, though often no additional shielding than that provided by structure is used due to mass and dimensional constraints. New materials are being developed which may offer advantages over these current solutions. These materials include novel lightweight composites impregnated with metallic nanoparticles, chitin-derived bioplastics, and aerogel-family materials. A compact CubeSat experiment payload that allows the simultaneous testing of numerus potential shielding materials would be useful to enable material comparison and efficacy validation. An effort currently underway seeks to develop such a miniaturized modularized payload, which will enable the testing of materials in 1U CubeSat form factor modules, with each module hosting four scintillator radiation detectors arrayed behind four sample material windows exposed to space. The first proposed mission will utilize a 2U payload volume to host two test quartets enabling eight materials to be tested. Such a test platform can potentially be used as a hosted payload on a variety of spacecraft to test additional materials in the future

Luke Idziak↗

Method and apparatus for two-dimensional spectroscopy

Preferred embodiments of the invention provide for methods and systems of 2D spectroscopy using ultrafast, first light and second light beams and a CCD array detector. A cylindrically-focused second light beam interrogates a target that is optically interactive with a frequency-dispersed excitation (first light) pulse, whereupon the second light beam is frequency-dispersed at right angle orientation to its line of focus, so that the horizontal dimension encodes the spatial location of the second light pulse and the first light frequency, while the vertical dimension encodes the second light frequency. Differential spectra of the first and second light pulses result in a 2D frequency-frequency surface equivalent to double-resonance spectroscopy. Because the first light frequency is spatially encoded in the sample, an entire surface can be acquired in a single interaction of the first and second light pulses.

DeCamp, Matthew F↗

Phenotypic Expression in Wheat Revealed Using FT-IR Microspectroscopy

Wheat selected for cultivation through the centuries has a glume that is 'soft' instead of 'tough' as naturally occurring. In production, this is desirable because it enables mechanical threshing with efficient separation of kernel from the head of each stalk without damaging the kernel. FT-IR microspectroscopy provides chemically based, objective assessment of genetic expression by measuring the extent of genetic expression. In the Microbeam Molecular Spectroscopy Laboratory, Manhattan, KS, an imaging FT-IR microspectrometer with a detector array focused on the image plane was used to obtain spectral data from dissected glume specimens of nine tough and eleven soft wheat cultivars in a rectangular mapping pattern. With cellulose as the substrate, the extent of lignification is measurable from the ratio of the lignin (1508 cm{sup -1}) baseline adjusted band area to the representative cellulosic (1370 cm{sup -1}) band area. A distinction between soft and tough glumes is obtained in numerical terms. Using a band ratio minimizes variation due to thickness differences. While analyzing mapped sections of glume, care is taken to avoid tabulation of spectral data from vascular bundles. Inclusion of these data would to avoid tabulation of spectral data from vascular bundles. Inclusion of these data would bias the analysis toward the composition of highly lignified vascular bundles. Spatially resolved focal plane array FT-IR microspectroscopy reveals the extent of glume lignification that is coincident with the toughness trait. This enables breeders to rank the degree of lignin expression and discriminate between soft and tough breeding results.

09 BIOMASS FUELS↗

IDENTIFICATION OF HIGH-SPIN STATES IN NEUTRON-RICH 88,90,92Kr AND 86Se

Level schemes of even-even neutron-rich {sup 88-92}Kr and {sup 86}Se have been investigated by measuring triple-{gamma} coincidence data from the spontaneous fission of {sup 252}Cf with the Gammasphere detector array. The level scheme of {sup 88}Kr has been extended up to 7169 keV state. Several new excited states with new transitions have been identified in {sup 90,92}Kr and {sup 86}Se. Spins and parities have been assigned to levels in these nuclei by following regional systematics and angular correlation measurements. The level structures of the N = 52, 54, Se, Kr, and Sr isotones are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A new technique for measuring astrophysically important (alpha,p) reactions

Studying ({alpha},p) reactions of astrophysical interest with radioactive beams presents serious challenges because of the difficult nature of the target. We have developed a new approach for the measurement of ({alpha},p) reactions using heavy ion beams in inverse kinematics and have measured the {sup 4}He({sup 19}F,{sup 1}H){sup 22}Ne reaction as a demonstration. {sup 19}F beams were used at the Holifield Radioactive Ion Beam Facility (HRIBF) tandem accelerator in Oak Ridge National Laboratory (ORNL) to bombard a large scattering chamber filled with {sup 4}He gas. Recoiling protons from the reactions were detected by the large area annular silicon strip detector array (SIDAR). The {sup 19}F({alpha},p) and {sup 19}F({alpha},p') excitation functions were measured over the energy range of E{sub c.m.} {approx} 1-2.1 MeV, demonstrating the viability of the technique

43 PARTICLE ACCELERATORS↗

Application of Spatially Resolved High Resolution Crystal Spectrometry to ICF Plasmas

High resolution (λ/Δ λ ~ 10 000) 1D imaging x-ray spectroscopy using a spherically bent crystal and a 2D hybrid pixel array detector is used world wide for Doppler measurements of ion-temperature and plasma flow-velocity profiles in magnetic confinement fusion plasmas. Meter sized plasmas are diagnosed with cm spatial resolution and 10 ms time resolution. This concept can also be used as a diagnostic of small sources, such as inertial confinement fusion plasmas and targets on x-ray light source beam lines, with spatial resolution of micrometers, as demonstrated by laboratory experiments using a 250-μm 55 Fe source, and by ray-tracing calculations. Throughput calculations agree with measurements, and predict detector counts in the range 10-8 -10-6 times source x-rays, depending on crystal reflectivity and spectrometer geometry. Results of the lab demonstrations, application of the technique to the National Ignition Facility (NIF), and predictions of performance on NIF will be presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Majorana Demonstrator

A brief review of the history and neutrino physics of double beta decay is given. A description of the MAJORANA DEMONSTRATOR research and development program, including background reduction techniques, is presented in some detail. The application of point contact (PC) detectors to the experiment is discussed, including the effectiveness of pulse shape analysis. The predicted sensitivity of a PC detector array enriched to 86% to 76Ge is given.

Aguayo, Estanislao↗

The Majorana Demonstrator search for neutrinoless double beta decay

The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, modular, HPGe detector array with a mass of 44.8-kg (29.7 kg enriched 88% in 76Ge) to search for neutrinoless double beta decay in 76Ge. The next generation of tonnescale Ge-based neutrinoless double beta decay searches will probe the neutrino mass scale in the inverted-hierarchy region. The MAJORANA DEMONSTRATOR is envisioned to demonstrate a path forward to achieve a background rate at or below 1 count/tonne/year in the 4 keV region of interest around the Q-value of 2039 keV. The MAJORANA DEMONSTRATOR follows a modular implementation to be easily scalable to the next generation experiment. First data taken with the DEMONSTRATOR are introduced here.

Cuesta, C.↗

Fuel cell

A fuel cell comprising a membrane electrode assembly, and an IR transmissive window for thermographic analysis of a surface of the membrane electrode assembly is described. The test fuel cell provides a method of monitoring a fuel cell, and capturing a thermographic profile of said fuel cell with an IR detector array, while simultaneously measuring the electrochemical output of the cell, including current, voltages and half cell potentials.

30 DIRECT ENERGY CONVERSION↗

Verification Data Pattern Recognition and Change Detection at the Neutron Instrument Level

As the pressure on International Atomic Energy Agency (IAEA) safeguards resources increases, there is a drive to essentially “do more with less.” New ways of using current verification instrumentation and visualizing the collected data are needed, coupled with maintaining and sustaining the current safeguards instrumentation fleet. This paper explores how to innovate with current safeguards neutron instrumentation using data-driven algorithms at the instrument level. A concept is described for upgrading current neutron counting systems with modern electronics by leveraging electronics developments in other fields (e.g., high-energy physics) to facilitate full list mode data acquisition and, therefore, expand existing analyses to pattern recognition and change detection at the instrument level. The aim is to advance correlated neutron counting by improving the reliability of detecting nuclear material diversion and, at the same time, to improve the sustainability of those systems. It is likely that upgrading existing systems with new hardware and software is more cost-effective than replacing systems with other novel systems that might meet this need. A specific project example is highlighted in which a system was upgraded by retrofitting the standard uranium neutron collar detector with new electronics; as a result, verification data can be analyzed in new ways. A new neutron analysis method, the “List Mode Response Matrix,” has been developed to analyze every pulse train from the detector array and thus enable the verification of spatial information about the assay item for safeguards inspections. This project has improved the reliability of resolving individual fuel pin locations within a given fresh fuel assembly and the percentage of partial defects detected. Herein, the overall concept of upgrading current neutron counting systems is discussed with respect to the potential increase in analysis capabilities. In addition, the details and results of the list mode collar project are discussed.

Worrall, Louise G.↗

Modular low cost trackerless spectral sensor

A photodiode sensor device and systems. The photodiode sensor device includes a housing portion. The housing portion includes a cylindrical enclosure. A window is disposed at a first end of the housing portion. A filter wheel is within the housing portion. A motor positioned within the housing is adjacent the filter wheel opposite the window. The motor is attached to the filter wheel. A photodiode sensor within the housing portion intermediate the first photodiode sensor and the window. The first photodiode sensor receives filtered light incident on the window and transmit a signal associated with sensed parameters of the filtered light. Also, a hemispherical dome for diffusing the light to a collimating lens has a grating, a focusing lens, and a linear detector array. An exit port transmits light to the collimating lens. The sensor array is opposite the grating for sensing the diffused light.

14 SOLAR ENERGY↗

Method and apparatus for evaluating superconducting tunnel junction detector noise versus bias voltage

A technique for characterizing the noise behavior of a superconducting tunnel junction (STJ) detector as a function of its applied bias voltage Vb by stepping the STJ's bias voltage across a predetermined range and, at each applied bias, making multiple measurements of the detector's current, calculating their mean and their standard deviation from their mean, and using this standard deviation as a measure of the STJ detector's noise at that applied bias. Because the method is readily executed under computer control, it is particularly useful when large numbers of STJ detectors require biasing, as in STJ detector arrays In a preferred implementation, the STJ is measured under computer control by attaching it to a digital spectrometer comprising a digital x-ray processor (DXP) coupled to a preamplifier that can set the STJ's bias voltage Vb using a digital-to-analog converter (DAC) controlled by the DXP.

Warburton, William K.↗