Search NASA⌕ Search

SEARCH · Search NASA

Results for “basic parameter model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

User's Guide for RESRAD-OFFSITE

The RESRAD-OFFSITE code can be used to model the radiological dose or risk to an offsite receptor. This User’s Guide for RESRAD-OFFSITE Version 3.1 is an update of the User’s Guide for RESRAD-OFFSITE Version 2 contained in the Appendix A of the User’s Manual for RESRAD-OFFSITE Version 2 (ANL/EVS/TM/07-1, DOE/HS-0005, NUREG/CR-6937). This user’s guide presents the basic information necessary to use Version 3.1 of the code. It also points to the help file and other documents that provide more detailed information about the inputs, the input forms and features/tools in the code; two of the features (overriding the source term and computing area factors) are discussed in the appendices to this guide. Section 2 describes how to download and install the code and then verify the installation of the code. Section 3 shows ways to navigate through the input screens to simulate various exposure scenarios and to view the results in graphics and text reports. Section 4 has screen shots of each input form in the code and provides basic information about each parameter to increase the user’s understanding of the code. Section 5 outlines the contents of all the text reports and the graphical output. It also describes the commands in the two output viewers. Section 6 deals with the probabilistic and sensitivity analysis tools available in the code. Section 7 details the various ways of obtaining help in the code.

61 RADIATION PROTECTION AND DOSIMETRY↗

Reduced order models for thermal analysis : final report : LDRD Project No. 137807.

This LDRD Senior's Council Project is focused on the development, implementation and evaluation of Reduced Order Models (ROM) for application in the thermal analysis of complex engineering problems. Two basic approaches to developing a ROM for combined thermal conduction and enclosure radiation problems are considered. As a prerequisite to a ROM a fully coupled solution method for conduction/radiation models is required; a parallel implementation is explored for this class of problems. High-fidelity models of large, complex systems are now used routinely to verify design and performance. However, there are applications where the high-fidelity model is too large to be used repetitively in a design mode. One such application is the design of a control system that oversees the functioning of the complex, high-fidelity model. Examples include control systems for manufacturing processes such as brazing and annealing furnaces as well as control systems for the thermal management of optical systems. A reduced order model (ROM) seeks to reduce the number of degrees of freedom needed to represent the overall behavior of the large system without a significant loss in accuracy. The reduction in the number of degrees of freedom of the ROM leads to immediate increases in computational efficiency and allows many design parameters and perturbations to be quickly and effectively evaluated. Reduced order models are routinely used in solid mechanics where techniques such as modal analysis have reached a high state of refinement. Similar techniques have recently been applied in standard thermal conduction problems e.g. though the general use of ROM for heat transfer is not yet widespread. One major difficulty with the development of ROM for general thermal analysis is the need to include the very nonlinear effects of enclosure radiation in many applications. Many ROM methods have considered only linear or mildly nonlinear problems. In the present study a reduced order model is considered for application to the combined problem of thermal conduction and enclosure radiation. The main objective is to develop a procedure that can be implemented in an existing thermal analysis code. The main analysis objective is to allow thermal controller software to be used in the design of a control system for a large optical system that resides with a complex radiation dominated enclosure. In the remainder of this section a brief outline of ROM methods is provided. The following chapter describes the fully coupled conduction/radiation method that is required prior to considering a ROM approach. Considerable effort was expended to implement and test the combined solution method; the ROM project ended shortly after the completion of this milestone and thus the ROM results are incomplete. The report concludes with some observations and recommendations.

42 ENGINEERING↗

Optics of colloidal quantum-confined CdSe nanoscrolls

Nanostructures in the form of 1.2-nm-thick colloidal CdSe nanoplatelets rolled into scrolls are investigated. The morphology of these scrolls is analysed and their basic geometric parameters are determined (diameter 29 nm, longitudinal size 100 – 150 nm) by TEM microscopy. Absorption and photoluminescence spectra of these objects are recorded, and the luminescence decay kinetics is studied. It is shown that the optical properties of CdSe nanoscrolls differ significantly from the properties of CdSe quantum dots and that these nanoscrolls are attractive for nanophotonic devices due to large oscillator strengths of the transition, small widths of excitonic peaks and short luminescence decay times. Nanoscrolls can be used to design hybrid organic–inorganic pure-color LEDs with a high luminescence quantum yield and low operating voltages. (optics and technology of nanostructures)

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The Enterprise Derivative Application: Flexible Software for Optimizing Manufacturing Processes

The Enterprise Derivative Application (EDA) implements the enterprise-derivative analysis for optimization of an industrial process (Allgood and Manges, 2001). It is a tool to help industry planners choose the most productive way of manufacturing their products while minimizing their cost. Developed in MS Access, the application allows users to input initial data ranging from raw material to variable costs and enables the tracking of specific information as material is passed from one process to another. Energy-derivative analysis is based on calculation of sensitivity parameters. For the specific application to a steel production process these include: the cost to product sensitivity, the product to energy sensitivity, the energy to efficiency sensitivity, and the efficiency to cost sensitivity. Using the EDA, for all processes the user can display a particular sensitivity or all sensitivities can be compared for all processes. Although energy-derivative analysis was originally designed for use by the steel industry, it is flexible enough to be applied to many other industrial processes. Examples of processes where energy-derivative analysis would prove useful are wireless monitoring of processes in the petroleum cracking industry and wireless monitoring of motor failure for determining the optimum time to replace motor parts. One advantage of the MS Access-based application is its flexibility in defining the process flow and establishing the relationships between parent and child process and products resulting from a process. Due to the general design of the program, a process can be anything that occurs over time with resulting output (products). So the application can be easily modified to many different industrial and organizational environments. Another advantage is the flexibility of defining sensitivity parameters. Sensitivities can be determined between all possible variables in the process flow as a function of time. Thus the dynamic development of the process can be tracked over time and optimized. EDA is a uniquely flexible and efficient way for planners to choose the most productive way of optimizing production while minimizing costs. The purpose of this document is to describe energy-derivative analysis and the operation of the application. The first section is an introduction of the concept, followed in Section 2 by a detailed description of the analysis approach. The third section provides a general overview of the operation of the application. The detailed description of the application is described in Section 4, using the still mill operation as an example. Conclusions regarding the utility of the EDA and the effectiveness of the implementation follow in Section 5. Appendix A describes details of setting up the process flow model and Appendix B provides information on overcoming an error that occurred in using the application on a PC that did not have Visual Basic installed.

02 PETROLEUM↗

Fracture-tough, corrosion-resistant bearing steels

The fundamental principles allowing design of stainless bearing steels with enhanced toughness and stress corrosion resistance has involved both investigation of basic phenomena in model alloys and evaluation of a prototype bearing steel based on a conceptual design exercise. Progress in model studies has included a scanning Auger microprobe (SAM) study of the kinetics of interfacial segregation of embrittling impurities which compete with the kinetics of alloy carbide precipitation in secondary hardening steels. These results can define minimum allowable carbide precipitation rates and/or maximum allowable free impurity contents in these ultrahigh strength steels. Characterization of the prototype bearing steel designed to combine precipitated austenite transformation toughening with secondary hardening shows good agreement between predicted and observed solution treatment response including the nature of the high temperature carbides. An approximate equilibrium constraint applied in the preliminary design calculations to maintain a high martensitic temperature proved inadequate, and the solution treated alloy remained fully austenitic down to liquid nitrogen temperature rather than transforming above 200 C. The alloy can be martensitically transformed by cryogenic deformation, and material so processed will be studied further to test predicted carbide and austenite precipitation behavior. A mechanistically-based martensitic kinetic model was developed and parameters are being evaluated from available kinetic data to allow precise control of martensitic temperatures of high alloy steels in future designs. Preliminary calculations incorporating the prototype stability results suggest that the transformation-toughened secondary-hardening martensitic-stainless design concept is still viable, but may require lowering Cr content to 9 wt. pct. and adding 0.5 to 1.0 wt. pct. Al. An alternative design approach based on strain-induced martensitic transformation during cryogenic forming, thus removing the high martensitic constraint, may permit alloy compositions offering higher fracture roughness.

Olson, Gregory B.↗

Five-Year Wilkinson Microwave Anisotropy Probe Observations: Data Processing, Sky Maps, and Basic Results

We present new full-sky temperature and polarization maps in five frequency bands from 23 to 94 GHz, based on data from the first five years of the Wilkinson Microwave Anisotropy Probe (WMAP) sky survey. The new maps are consistent with previous maps and are more sensitive. The five-year maps incorporate several improvements in data processing made possible by the additional years of data and by a more complete analysis of the instrument calibration and in-flight beam response. We present several new tests for systematic errors in the polarization data and conclude that W-band polarization data is not yet suitable for cosmological studies, but we suggest directions for further study. We do find that Ka-band data is suitable for use; in conjunction with the additional years of data, the addition of Ka band to the previously used Q- and V-band channels significantly reduces the uncertainty in the optical depth parameter, tau. Further scientific results from the five-year data analysis are presented in six companion papers and are summarized in Section 7 of this paper. With the five-year WMAP data, we detect no convincing deviations from the minimal six-parameter ACDM model: a flat universe dominated by a cosmological constant, with adiabatic and nearly scale-invariant Gaussian fluctuations. Using WMAP data combined with measurements of Type Ia supernovae and Baryon Acoustic Oscillations in the galaxy distribution, we find (68% CL uncertainties): OMEGA(sub b)h(sup 2) = 0.02267(sup +0.00058)(sub -0.00059), OMEGA(sub c)h(sup 2) = 0.1131 plus or minus 0.0034, OMEGA(sub logical and) = 0.726 plus or minus 0.015, ns = .960 plus or minus 0.013, tau = 0.84 plus or minus 0.016, and DELTA(sup 2)(sub R) = (22.445 plus or minus 0.096) x 10(exp -9) at k = 0.002 Mpc(exp -1). From these we derive sigma(sub 8) = 0.812 plus or minus 0.026, H(sub 0) = 70.5 plus or minus 1.3 kilometers per second Mpc(exp -1), OMEGA(sub b) = 0.0456 plus or minus 0.0015, OMEGA(sub c) = .228 plus or minus 0.013, OMEGA(sub m)h(sup 2) = 0.1358(sup +0.0037)(sub -0.0036), z reion = 10.9 plus or minus 1.4, and t(sub 0) = 13.72 plus or minus 0.12 Gyr. The new limit on the tensor-to-scalar ration is r less than 0.22 (95% CL), while the evidence for a running spectral index is insignificant, dn(sub s)/d ln k = -0.028 plus or minus 0.020 (68% CL). We obtain tight, simultaneous limits on the (constant) dark energy equation of state and the spatial curvature of the universe: -0.14 less than 1 + w less than 0.12 (95% CL) and -0.0179 less than OMEGA(sub k) less than 0.0081 (95% CL). The number of relativistic degrees of freedom, expressed in units of the effective number of neutrino species, is found to be N(sub eff) = 4.4 plus or minus 1.5 (69% CL), consistent with the standard value of 3.04. Models with N(sub eff) = 0 are disfavored at greater than 99% confidence. Finally, new limits on physically motivated primordial non-Gaussianity parameters are -9 less than f(sup local)(sub NL) less than 111 (95% CL) and -151 less than f(sup equal)(sub NL) less than 253 (95% CL) for the local and equilateral models, respectively.

Hinshaw, G.↗

FIVE-YEAR WILKINSON MICROWAVE ANISOTROPY PROBE OBSERVATIONS: DATA PROCESSING, SKY MAPS, AND BASIC RESULTS

We present new full-sky temperature and polarization maps in five frequency bands from 23 to 94 GHz, based on data from the first five years of the Wilkinson Microwave Anisotropy Probe (WMAP) sky survey. The new maps are consistent with previous maps and are more sensitive. The five-year maps incorporate several improvements in data processing made possible by the additional years of data and by a more complete analysis of the instrument calibration and in-flight beam response. We present several new tests for systematic errors in the polarization data and conclude that W-band polarization data is not yet suitable for cosmological studies, but we suggest directions for further study. We do find that Ka-band data is suitable for use; in conjunction with the additional years of data, the addition of Ka band to the previously used Q- and V-band channels significantly reduces the uncertainty in the optical depth parameter, {tau}. Further scientific results from the five-year data analysis are presented in six companion papers and are summarized in Section 7 of this paper. With the five-year WMAP data, we detect no convincing deviations from the minimal six-parameter {lambda}CDM model: a flat universe dominated by a cosmological constant, with adiabatic and nearly scale-invariant Gaussian fluctuations. Using WMAP data combined with measurements of Type Ia supernovae and Baryon Acoustic Oscillations in the galaxy distribution, we find (68% CL uncertainties): {omega} {sub b} h {sup 2} = 0.02267{sup +0.00058} {sub -0.00059}, {omega} {sub c} h {sup 2} = 0.1131 {+-} 0.0034, {omega}{sub {lambda}} = 0.726 {+-} 0.015, n{sub s} = 0.960 {+-} 0.013, {tau} = 0.084 {+-} 0.016, and {delta}{sub R}{sup 2} = (2.445{+-}0.096)x10{sup -9} at k = 0.002 Mpc{sup -1}. From these we derive {sigma}{sub 8} = 0.812 {+-} 0.026, H {sub 0} = 70.5 {+-} 1.3 km s{sup -1} Mpc{sup -1}, {omega} {sub b} = 0.0456 {+-} 0.0015, {omega} {sub c} = 0.228 {+-} 0.013, {omega} {sub m} h {sup 2} = 0.1358{sup +0.0037} {sub -0.0036}, z {sub reion} = 10.9 {+-} 1.4, and t {sub 0} = 13.72 {+-} 0.12 Gyr. The new limit on the tensor-to-scalar ratio is r < 0.22(95%CL), while the evidence for a running spectral index is insignificant, dn{sub s} /dln k = -0.028 {+-} 0.020 (68% CL). We obtain tight, simultaneous limits on the (constant) dark energy equation of state and the spatial curvature of the universe: -0.14 < 1 + w < 0.12(95%CL) and -0.0179 < {omega} {sub k} < 0.0081(95%CL). The number of relativistic degrees of freedom, expressed in units of the effective number of neutrino species, is found to be N {sub eff} = 4.4 {+-} 1.5 (68% CL), consistent with the standard value of 3.04. Models with N {sub eff} = 0 are disfavored at >99.5% confidence. Finally, new limits on physically motivated primordial non-Gaussianity parameters are -9 < f {sup local} {sub NL} < 111 (95% CL) and -151 < f {sup equil} {sub NL} < 253 (95% CL) for the local and equilateral models, respe0013ctive.

79 ASTRONOMY AND ASTROPHYSICS↗

Disposable Electrochemical Immunosensor Diagnosis Device Based on Nanoparticle Probe and Immunochromatographic Strip

We describe a disposable electrochemical immunosensor diagnosis device that is based on the immunochromatographic strip technique and an electrochemical immunoassay based on quantum dot (QD, CdS@ZnS) labels. The device takes advantage of the speed and low-cost of the conventional immunochromatographic strip test and the high-sensitivity of the nanoparticle-based electrochemical immunoassay. A sandwich immunoreaction was performed on the immunochromatographic strip, and the captured QD labels in the test zone were determined by highly sensitive stripping voltammetric measurement of the dissolved metallic component (cadmium) with a disposable-screen-printed electrode, which is embedded underneath the membrane on the test zone. The new device coupled with a portable electrochemical analyzer shows great promise for in-field and point-of-care quantitative testing of disease-related protein biomarkers. The parameters (e.g., voltammetric measurement of QD labels, antibody immobilization, the loading amount of QD-antibody, and the immunoreaction time) that govern the sensitivity and reproducibility of the device were optimized with IgG model analyte. The voltammetric response of the optimized device is highly linear over the range of 0.1 to 10 ng mL-1 IgG, and the limit of detection is estimated to be 30 pg mL-1 in association with a 7-min immunoreaction time. The detection limit was improved to 10 pg mL-1 using a 20-min immunoreaction time. The new disposable electrochemical diagnosis device thus provides a more user-friendly, rapid, clinically accurate, less expensive, and quantitative tool for protein detection.

59 BASIC BIOLOGICAL SCIENCES↗

Calibration of ITER Instant Power Neutron Monitors: Recommended Scenario of Experiments at the Reactor

Instant power is a key parameter of the ITER. Its monitoring with an accuracy of a few percent is an urgent and challenging aspect of neutron diagnostics. In a series of works published in Problems of Atomic Science and Technology, Series: Thermonuclear Fusion under a common title, the step-by-step neutronics analysis was given to substantiate a calibration technique for the DT and DD modes of the ITER. A Gauss quadrature scheme, optimal for processing “expensive” experiments, is used for numerical integration of {sup 235}U and {sup 238}U detector responses to the point sources of 14-MeV neutrons. This approach allows controlling the integration accuracy in relation to the number of coordinate mesh points and thus minimizing the number of irradiations at the given uncertainty of the full monitor response. In the previous works, responses of the divertor and blanket monitors to the isotropic point sources of DT and DD neutrons in the plasma profile and to the models of real sources were calculated within the ITER model using the MCNP code. The neutronics analyses have allowed formulating the basic principles of calibration that are optimal for having the maximum accuracy at the minimum duration of in situ experiments at the reactor. In this work, scenarios of the preliminary and basic experimental ITER runs are suggested on the basis of those principles. It is proposed to calibrate the monitors only with DT neutrons and use correction factors to the DT mode calibration for the DD mode. It is reasonable to perform full calibration only with {sup 235}U chambers and calibrate {sup 238}U chambers by responses of the {sup 235}U chambers during reactor operation (cross-calibration). The divertor monitor can be calibrated using both direct measurement of responses at the Gauss positions of a point source and simplified techniques based on the concepts of equivalent ring sources and inverse response distributions, which will considerably reduce the amount of measurements. It is shown that the monitor based on the average responses of the horizontal and vertical neutron chambers remains spatially stable as the source moves and can be used in addition to the staff monitor at neutron fluxes in the detectors four orders of magnitude lower than on the first wall, where staff detectors are located. Owing to low background, detectors of neutron chambers do not need calibration in the reactor because it is actually determination of the absolute detector efficiency for 14-MeV neutrons, which is a routine out-of-reactor procedure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mechanistic within-host mathematical model of inhalational anthrax

We present a mathematical model of the dynamics of Bacillus anthracis bacteria within the lymph nodes and blood of a host, following inhalation of an initial dose of spores. We also incorporate the dynamics of protective antigen, which is the binding component of the anthrax toxin produced by the bacteria. The model offers a mechanistic description of the early infection dynamics of inhalational anthrax, while its stochastic nature allows us to study the probabilities of different outcomes (for example, how likely it is that the infection will be cleared for a given inhaled dose of spores) in order to explain dose-response data for inhalational anthrax. The model is calibrated via a Bayesian approach, using in vivo data from New Zealand white rabbit and guinea pig infection studies, enabling within-host parameters to be estimated. We also leverage incubation-period data from the Sverdlovsk 1979 anthrax outbreak to show that the model can accurately describe human time-to-symptoms data under reasonable parameter regimes. Finally, we derive a simple approximate formula for the probability of symptom onset before time t, assuming that the number of inhaled spores has a Poisson distribution.

59 BASIC BIOLOGICAL SCIENCES↗

Predictability and reduced order modeling in stochastic reaction networks.

Many systems involving chemical reactions between small numbers of molecules exhibit inherent stochastic variability. Such stochastic reaction networks are at the heart of processes such as gene transcription, cell signaling or surface catalytic reactions, which are critical to bioenergy, biomedical, and electrical storage applications. The underlying molecular reactions are commonly modeled with chemical master equations (CMEs), representing jump Markov processes, or stochastic differential equations (SDEs), rather than ordinary differential equations (ODEs). As such reaction networks are often inferred from noisy experimental data, it is not uncommon to encounter large parametric uncertainties in these systems. Further, a wide range of time scales introduces the need for reduced order representations. Despite the availability of mature tools for uncertainty/sensitivity analysis and reduced order modeling in deterministic systems, there is a lack of robust algorithms for such analyses in stochastic systems. In this talk, we present advances in algorithms for predictability and reduced order representations for stochastic reaction networks and apply them to bistable systems of biochemical interest. To study the predictability of a stochastic reaction network in the presence of both parametric uncertainty and intrinsic variability, an algorithm was developed to represent the system state with a spectral polynomial chaos (PC) expansion in the stochastic space representing parametric uncertainty and intrinsic variability. Rather than relying on a non-intrusive collocation-based Galerkin projection [1], this PC expansion is obtained using Bayesian inference, which is ideally suited to handle noisy systems through its probabilistic formulation. To accommodate state variables with multimodal distributions, an adaptive multiresolution representation is used [2]. As the PC expansion directly relates the state variables to the uncertain parameters, the formulation lends itself readily to sensitivity analysis. Reduced order modeling in the time dimension is accomplished using a Karhunen-Loeve (KL) decomposition of the stochastic process in terms of the eigenmodes of its covariance matrix. Subsequently, a Rosenblatt transformation relates the random variables in the KL decomposition to a set of independent random variables, allowing the representation of the system state with a PC expansion in those independent random variables. An adaptive clustering method is used to handle multimodal distributions efficiently, and is well suited for high-dimensional spaces. The spectral representation of the stochastic reaction networks makes these systems more amenable to analysis, enabling a detailed understanding of their functionality, and robustness under experimental data uncertainty and inherent variability.

59 BASIC BIOLOGICAL SCIENCES↗

A workflow for segmenting soil and plant X-ray computed tomography images with deep learning in Google’s Colaboratory

X-ray micro-computed tomography (X-ray μCT) has enabled the characterization of the properties and processes that take place in plants and soils at the micron scale. Despite the widespread use of this advanced technique, major limitations in both hardware and software limit the speed and accuracy of image processing and data analysis. Recent advances in machine learning, specifically the application of convolutional neural networks to image analysis, have enabled rapid and accurate segmentation of image data. Yet, challenges remain in applying convolutional neural networks to the analysis of environmentally and agriculturally relevant images. Specifically, there is a disconnect between the computer scientists and engineers, who build these AI/ML tools, and the potential end users in agricultural research, who may be unsure of how to apply these tools in their work. Additionally, the computing resources required for training and applying deep learning models are unique, more common to computer gaming systems or graphics design work, than to traditional computational systems. To navigate these challenges, we developed a modular workflow for applying convolutional neural networks to X-ray μCT images, using low-cost resources in Google’s Colaboratory web application. Here we present the results of the workflow, illustrating how parameters can be optimized to achieve best results using example scans from walnut leaves, almond flower buds, and a soil aggregate. We expect that this framework will accelerate the adoption and use of emerging deep learning techniques within the plant and soil sciences.

59 BASIC BIOLOGICAL SCIENCES↗

Parametrization and Benchmark of Long-Range Corrected DFTB2 for Organic Molecules

In this paper, we present the parametrization and benchmark of long-range corrected second-order density functional tight binding (DFTB), LC-DFTB2, for organic and biological molecules. The LC-DFTB2 model not only improves fundamental orbital energy gaps but also ameliorates the DFT self-interaction error and overpolarization problem, and further improves charge-transfer excited states significantly. Electronic parameters for the construction of the DFTB2 Hamiltonian as well as repulsive potentials were optimized for molecules containing C, H, N, and O chemical elements. We use a semiautomatic parametrization scheme based on a genetic algorithm. With the new parameters, LC-DFTB2 describes geometries and vibrational frequencies of organic molecules similarly well as third-order DFTB3/3OB, the de facto standard parametrization based on a GGA functional. Finally, LC-DFTB2 performs well also for atomization and reaction energies, however, slightly less satisfactorily than DFTB3/3OB.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CONSTRAINT ON THE PARAMETERS OF THE INVERSE COMPTON SCATTERING MODEL FOR RADIO PULSARS

The inverse Compton scattering (ICS) model can explain various pulse profile shapes and the diversity of the pulse profile evolution based on the mechanism where the radio emission is generated through ICS between secondary relativistic particles and radio waves from polar gap avalanches. In this paper, we study the parameter space of the ICS model for 15 pulsars that share the common pulse profile evolution phenomenon, where the pulse profiles are narrower at higher observing frequencies. Two key parameters, the initial Lorentz factor and the energy loss factor of secondary particles, are constrained using the least-squares fitting method, where we fit the theoretical curve of the 'beam-frequency mapping' of the ICS model to the observed pulse widths at multiple frequencies. The uncertainty of the inclination and viewing angles are taken into account in the fitting process. It is found that the initial Lorentz factor is larger than 4000, and the energy loss factor is between 20 and 560. The Lorentz factor is consistent with the prediction of the inner vacuum gap model. Such high-energy loss factors suggest significant energy loss for secondary particles at altitudes of a few tens to hundreds of kilometers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-F-16A-02: Simulation of a Medical Linear Accelerator for Teaching Purposes

Purpose: Detailed functioning of linear accelerator physics is well known. Less well developed is the basic understanding of how the adjustment of the linear accelerator's electrical components affects the resulting radiation beam. Other than the text by Karzmark, there is very little literature devoted to the practical understanding of linear accelerator functionality targeted at the radiotherapy clinic level. The purpose of this work is to describe a simulation environment for medical linear accelerators with the purpose of teaching linear accelerator physics. Methods: Varian type lineacs were simulated. Klystron saturation and peak output were modelled analytically. The energy gain of an electron beam was modelled using load line expressions. The bending magnet was assumed to be a perfect solenoid whose pass through energy varied linearly with solenoid current. The dose rate calculated at depth in water was assumed to be a simple function of the target's beam current. The flattening filter was modelled as an attenuator with conical shape, and the time-averaged dose rate at a depth in water was determined by calculating kerma. Results: Fifteen analytical models were combined into a single model called SIMAC. Performance was verified systematically by adjusting typical linac control parameters. Increasing klystron pulse voltage increased dose rate to a peak, which then decreased as the beam energy was further increased due to the fixed pass through energy of the bending magnet. Increasing accelerator beam current leads to a higher dose per pulse. However, the energy of the electron beam decreases due to beam loading and so the dose rate eventually maximizes and the decreases as beam current was further increased. Conclusion: SIMAC can realistically simulate the functionality of a linear accelerator. It is expected to have value as a teaching tool for both medical physicists and linear accelerator service personnel.

43 PARTICLE ACCELERATORS↗

Density Functional Theory Calculation of Bonding and Charge Parameters for Molecular Dynamics Studies of [FeFe] Hydrogenases

We have developed and tested molecular mechanics parameters for [FeS] clusters found in known [FeFe] hydrogenases. Bond stretching, angle bending, dihedral and improper torsion parameters for models of the oxidized and reduced catalytic H-cluster, [4Fe4S]{sup +,2+}Cys{sub 4}, [4Fe4S]{sup +,2+}Cys{sub 3}His, and [2Fe2S]{sup +,2+}Cys{sub 4}, were calculated solely from Kohn-Sham density functional theory and Natural Population Analysis. Circumsphere analysis of the cubane clusters in the energy-minimized structure of the full Clostridium pasteurianum hydrogenase I showed the resulting metallocluster structures to be similar to known cubane structures. All clusters were additionally stable in molecular dynamics simulations over the course of 1.0 ns in the fully oxidized and fully reduced enzyme models. Normal modes calculated by quasiharmonic analysis from the dynamics data show unexpected couplings among internal coordinate motions, which may reflect the effects of the protein structure on metallocluster dynamics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cosmology and astrophysics from relaxed galaxy clusters – V. Consistency with cold dark matter structure formation

This is the fifth in a series of papers studying the astrophysics and cosmology of massive, dynamically relaxed galaxy clusters. Our sample comprises 40 clusters identified as being dynamically relaxed and hot in Papers I and II of this series. Here we use constraints on cluster mass profiles from X-ray data to test some of the basic predictions of cosmological structure formation in the cold dark matter (CDM) paradigm. In addition, we present constraints on the concentration–mass relation for massive clusters, finding a power-law mass dependence with a slope of κ m = –0.16 ± 0.07, in agreement with CDM predictions. For this relaxed sample, the relation is consistent with a constant as a function of redshift (power-law slope with 1 + z of κ ζ = –0.17 ± 0.26), with an intrinsic scatter of σln c = 0.16 ± 0.03. We investigate the shape of cluster mass profiles over the radial range probed by the data (typically ~50 kpc–1 Mpc), and test for departures from the simple Navarro–Frenk–White (NFW) form, for which the logarithmic slope of the density profile tends to –1 at small radii. Specifically, we consider as alternatives the generalized NFW (GNFW) and Einasto parametrizations. For the GNFW model, we find an average value of (minus) the logarithmic inner slope of β = 1.02 ± 0.08, with an intrinsic scatter of σ β = 0.22 ± 0.07, while in the Einasto case we constrain the average shape parameter to be α = 0.29 ± 0.04 with an intrinsic scatter of σ α = 0.12 ± 0.04. Our results are thus consistent with the simple NFW model on average, but we clearly detect the presence of intrinsic, cluster-to-cluster scatter about the average.

79 ASTRONOMY AND ASTROPHYSICS↗

Long-time mean-square displacements in proteins

We propose a method for obtaining the intrinsic, long-time mean square displacement (MSD) of atoms and molecules in proteins from finite-time molecular dynamics (MD) simulations. Typical data from simulations are limited to times of 1 to 10 ns, and over this time period the calculated MSD continues to increase without a clear limiting value. The proposed method consists of fitting a model to MD simulation-derived values of the incoherent intermediate neutron scattering function, I inc (Q,t), for finite times. The infinite-time MSD, r 2 , appears as a parameter in the model and is determined by fits of the model to the finite-time I inc (Q,t). Specifically, the r 2 is defined in the usual way in terms of the Debye-Waller factor as I(Q,t = ∞) = exp( –Q 2 r 2 /3). The method is illustrated by obtaining the intrinsic MSD r 2 of hydrated lysozyme powder (h = 0.4 g water/g protein) over a wide temperature range. The intrinsic r 2 obtained from data out to 1 and to 10 ns is found to be the same. In conclusion, the intrinsic r 2 is approximately twice the value of the MSD that is reached in simulations after times of 1 ns which correspond to those observed using neutron instruments that have an energy resolution width of 1 μeV.

59 BASIC BIOLOGICAL SCIENCES↗