At least 1,585 records · Page 88

Systematic uncertainties in the Monte Carlo calculation of ion chamber replacement correction factors

In a previous study [Med. Phys. 35, 1747-1755 (2008)], the authors proposed two direct methods of calculating the replacement correction factors (P{sub repl} or p{sub cav}p{sub dis}) for ion chambers by Monte Carlo calculation. By ''direct'' we meant the stopping-power ratio evaluation is not necessary. The two methods were named as the high-density air (HDA) and low-density water (LDW) methods. Although the accuracy of these methods was briefly discussed, it turns out that the assumption made regarding the dose in an HDA slab as a function of slab thickness is not correct. This issue is reinvestigated in the current study, and the accuracy of the LDW method applied to ion chambers in a {sup 60}Co photon beam is also studied. It is found that the two direct methods are in fact not completely independent of the stopping-power ratio of the two materials involved. There is an implicit dependence of the calculated P{sub repl} values upon the stopping-power ratio evaluation through the choice of an appropriate energy cutoff {Delta}, which characterizes a cavity size in the Spencer-Attix cavity theory. Since the {Delta} value is not accurately defined in the theory, this dependence on the stopping-power ratio results in a systematic uncertainty on the calculated P{sub repl} values. For phantom materials of similar effective atomic number to air, such as water and graphite, this systematic uncertainty is at most 0.2% for most commonly used chambers for either electron or photon beams. This uncertainty level is good enough for current ion chamber dosimetry, and the merits of the two direct methods of calculating P{sub repl} values are maintained, i.e., there is no need to do a separate stopping-power ratio calculation. For high-Z materials, the inherent uncertainty would make it practically impossible to calculate reliable P{sub repl} values using the two direct methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characteristics of Flow Field for Supersonic Oxygen Multijets with Various Laval Nozzle Structures

The Laval nozzle is used widely in steelmaking processes to increase the velocity of an oxygen jet up to approximately 2 Mach numbers. The present research is aimed at determining the effect of the Laval nozzle structure on a supersonic oxygen jet flow field. Both one-dimensional isoentropic flow theory and a characteristic-line method were used to design five-hole oxygen lances of two types and, applicable to oxygen multijets, to analyze their flow field characteristics by a series of numerical simulations and experimental studies. When compared to the conventional oxygen lance designed according to the one-dimensional isoentropic flow theory, the new oxygen lance designed with employment of the characteristic-line method is more effective in both suppressing the shock wave generation and improving the initial axial velocity of oxygen jets under the same test conditions. As a result, a larger impaction cavity was generated by the new oxygen lance and the mass transfer within oxygen, liquid slag, and molten steel was enhanced.

36 MATERIALS SCIENCE↗

Dose-Volume Histogram Predictors of Chronic Gastrointestinal Complications After Radical Hysterectomy and Postoperative Concurrent Nedaplatin-Based Chemoradiation Therapy for Early-Stage Cervical Cancer

Purpose: The purpose of this study was to evaluate dose-volume histogram (DVH) predictors for the development of chronic gastrointestinal (GI) complications in cervical cancer patients who underwent radical hysterectomy and postoperative concurrent nedaplatin-based chemoradiation therapy. Methods and Materials: This study analyzed 97 patients who underwent postoperative concurrent chemoradiation therapy. The organs at risk that were contoured were the small bowel loops, large bowel loop, and peritoneal cavity. DVH parameters subjected to analysis included the volumes of these organs receiving more than 15, 30, 40, and 45 Gy (V15-V45) and their mean dose. Associations between DVH parameters or clinical factors and the incidence of grade 2 or higher chronic GI complications were evaluated. Results: Of the clinical factors, smoking and low body mass index (BMI) (<22) were significantly associated with grade 2 or higher chronic GI complications. Also, patients with chronic GI complications had significantly greater V15-V45 volumes and higher mean dose of the small bowel loops compared with those without GI complications. In contrast, no parameters for the large bowel loop or peritoneal cavity were significantly associated with GI complications. Results of the receiver operating characteristics (ROC) curve analysis led to the conclusion that V15-V45 of the small bowel loops has high accuracy for prediction of GI complications. Among these parameters, V40 gave the highest area under the ROC curve. Finally, multivariate analysis was performed with V40 of the small bowel loops and 2 other clinical parameters that were judged to be potential risk factors for chronic GI complications: BMI and smoking. Of these 3 parameters, V40 of the small bowel loops and smoking emerged as independent predictors of chronic GI complications. Conclusions: DVH parameters of the small bowel loops may serve as predictors of grade 2 or higher chronic GI complications after postoperative concurrent nedaplatin-based chemoradiation therapy for early-stage cervical cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A weighted ℓ{sub 1}-minimization approach for sparse polynomial chaos expansions

This work proposes a method for sparse polynomial chaos (PC) approximation of high-dimensional stochastic functions based on non-adapted random sampling. We modify the standard ℓ{sub 1}-minimization algorithm, originally proposed in the context of compressive sampling, using a priori information about the decay of the PC coefficients, when available, and refer to the resulting algorithm as weightedℓ{sub 1}-minimization. We provide conditions under which we may guarantee recovery using this weighted scheme. Numerical tests are used to compare the weighted and non-weighted methods for the recovery of solutions to two differential equations with high-dimensional random inputs: a boundary value problem with a random elliptic operator and a 2-D thermally driven cavity flow with random boundary condition.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-Fidelity RF Gun Simulations with the Parallel 3D Finite Element Particle-In-Cell Code Pic3P

SLAC's Advanced Computations Department (ACD) has developed the first parallel Finite Element 3D Particle-In-Cell (PIC) code, Pic3P, for simulations of RF guns and other spacecharge dominated beam-cavity interactions. Pic3P solves the complete set of Maxwell-Lorentz equations and thus includes space charge, retardation and wakefield effects from first principles. Pic3P uses higher-order Finite Element methods on unstructured conformal meshes. A novel scheme for causal adaptive refinement and dynamic load balancing enable unprecedented simulation accuracy, aiding the design and operation of the next generation of accelerator facilities. Application to the Linac Coherent Light Source (LCLS) RF gun is presented.

43 PARTICLE ACCELERATORS↗

The role of correlation in the ground state energy of confined helium atom

We analyze the ground state energy of helium atom confined by spherical impenetrable walls, and the role of the correlation energy in the total energy. The confinement of an atom in a cavity is one way in which we can model the effect of the external pressure on an atom. The calculations of energy of the system are carried out by the variational method. We find that the correlation energy remains almost constant for a range values of size of the boxes analyzed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Injection locking of a high power ultraviolet laser diode for laser cooling of ytterbium atoms

We developed a high-power laser system at a wavelength of 399 nm for laser cooling of ytterbium atoms with ultraviolet laser diodes. The system is composed of an external cavity laser diode providing frequency stabilized output at a power of 40 mW and another laser diode for amplifying the laser power up to 220 mW by injection locking. The systematic method for optimization of our injection locking can also be applied to high power light sources at any other wavelengths. Our system does not depend on complex nonlinear frequency-doubling and can be made compact, which will be useful for providing light sources for laser cooling experiments including transportable optical lattice clocks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Entanglement generation between distant atoms by Lyapunov control

We show how to apply Lyapunov control design to the problem of entanglement creation between two atoms in distant cavities connected by optical fibers. The Lyapunov control design is optimal in the sense that the distance from the target state decreases monotonically and exponentially, and the concurrence increases accordingly. This method is far more robust than simple geometric schemes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-F-T-645: To Test Spatial Anddosimetric Accuracy of Small Cranial Target Irradiation Based On 1.5 T MRIscans Using Static Arcs with MLCDefined Fields

Purpose: To test spatial and dosimetric accuracy of small cranial target irradiation based on 1.5 T MRI scans using static arcs with MLC-defined fields Methods: A plastic (PMMA) phantom simulating a small brain lesion was mounted on a GammaKnife headframe equipped with MRI localizer. The lesion was a 3 mm long, 3.175 mm diameter cylindrical cavity filled with MRI contrast. Radiochromic film passing through the cavity was marked with pin pricks at the cavity center. The cavity was contoured on an MRI image and fused with CT to simulate treatment of a lesion not visible on CT. The transfer of the target to CT involved registering the MRI contrast cannels of the localizer that were visible on both modalities. Treatments were planned to deliver 800 cGy to the cavity center using multiple static arcs with 5.0×2.4 mm MLC-defined fields. The phantom was aligned on a STx accelerator by registering the conebeam CT with the planning CT. Films from coronal and sagittal planes were scanned and evaluated using ImageJ software Results: Geographic errors in treatment based on 1.5 T scans agreed within 0.33, −0.27 and 1.21 mm in the vertical, lateral and longitudinal dimensions, respectively. The doses delivered to the cavity center were 7.2% higher than planned. The dose distributions were similar to those of a GammaKnife. Conclusion: Radiation can be delivered with an accelerator at mm accuracy to small cranial targets based on 1.5 MRI scans fused to CTs using a standard GammaKnife headframe and MRI localizer. MLC-defined static arcs produce isodose lines very similar to the GammaKnife.

60 APPLIED LIFE SCIENCES↗

Systematic effects in neutron coincidence and multiplicity counting

Correlated neutron counting, including neutron coincidence and multiplicity counting, is an important tool in nuclear material accountancy verification. The accuracy of such measurements is of interest to the safeguards community because as the accuracy of NDA improves, the number of samples that are required to undergo destructive analysis (DA) decreases. The accuracy of a neutron mUltiplicity measurement can be affected by a number of variables. Monte Carlo neutron transport simulations with MCNPX have been performed to understand how the properties of the sample affect the count rate. These resultant count rates have been analyzed with the 'point model' in order to determine the effect on the deduced plutonium mass. The sample properties that have been investigated are density, sample position within the detector cavity, moisture content, isotopic composition, plutonium to total actinide ratio and heavy metal fraction. These parameters affect the Singles, Doubles and Triples count rates in different ways. In addition, different analysis methods use these measured quantities in different combinations, so that the final sensitivity of the {sup 240}Pu mass to each parameter also depends on the analysis method used. For example, the passive calibration curve method only used the Doubles rate to produce the {sup 240}Pu mass and so is not sensitive to changes in the Singles rate (to first order). The analysis methods considered here were passive calibration curve (non-multiplication corrected), known alpha (multiplication corrected) and multiplicity with known efficiency. The effects were studied on both a small mass MOX sample (1 g Pu) and a large MOX sample (6000 g Pu) both measured in high efficiency neutron multiplicity counters. In order to determine the final effect of each parameter it is necessary to know not only the sensitivity of the plutonium mass to that parameter, but also the range over which the parameter can realistically vary. Some estimates are given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method to planarize three-dimensional structures to enable conformal electrodes

Methods for fabricating three-dimensional PIN structures having conformal electrodes are provided, as well as the structures themselves. The structures include a first layer and an array of pillars with cavity regions between the pillars. A first end of each pillar is in contact with the first layer. A segment is formed on the second end of each pillar. The cavity regions are filled with a fill material, which may be a functional material such as a neutron sensitive material. The fill material covers each segment. A portion of the fill material is etched back to produce an exposed portion of the segment. A first electrode is deposited onto the fill material and each exposed segment, thereby forming a conductive layer that provides a common contact to each the exposed segment. A second electrode is deposited onto the first layer.

36 MATERIALS SCIENCE↗

Emittance characterization of a hot-cavity laser ion source at Holifield Radioactive Ion Beam Facility

The first investigation of the transverse emittance of a hot-cavity laser ion source based on all-solid-state Ti:sapphire lasers is presented. The emittances of {sup 63}Cu ion beams generated by three-photon resonant ionization are measured and compared with that of the {sup 69}Ga and {sup 39}K ion beams resulting from surface ionization in the same ion source. A self-consistent unbiased elliptical exclusion method is adapted for noise reduction and emittance analysis. Typical values of the rms and 90% fractional emittances of the Cu ion beams at 20 keV energy are found to be about 2 and 8 {pi} mm mrad, respectively, for the ion currents of 2-40 nA investigated. The emittances of the laser-produced Cu ion beams are smaller than those of the surface-ionized Ga and K ion beams.

43 PARTICLE ACCELERATORS↗

HINS Superconducting Lens and Cryostat Performance

Fermi National Accelerator Laboratory is involved in the development of a 60 MeV superconducting linac. This linac is part of the High Intensity Neutrino Source (HINS) R&D Program. The initial beam acceleration in the front end section of the linac is achieved using room temperature spoke cavities, each of which is combined with a superconducting focusing solenoid. These solenoid magnets are cooled with liquid helium at 4.5K, operate at 250 A and have a maximum magnetic field strength of 7.5 T. A prototype solenoid cryostat was built and tested at the Fermilab Magnet Test Facility. This paper discusses the test results of the prototype and compares the measured and estimated performance of the cryostat. We also present the methods and results for measuring and fiducializing the axis of the solenoid lens.

43 PARTICLE ACCELERATORS↗

An overview of modeling methods for thermal mixing and stratification in large enclosures for reactor safety analysis

Thermal mixing and stratification phenomena play major roles in the safety of reactor systems with large enclosures, such as containment safety in current fleet of LWRs, long-term passive containment cooling in Gen III+ plants including AP-1000 and ESBWR, the cold and hot pool mixing in pool type sodium cooled fast reactor systems (SFR), and reactor cavity cooling system behavior in high temperature gas cooled reactors (HTGR), etc. Depending on the fidelity requirement and computational resources, 0-D steady state models (heat transfer correlations), 0-D lumped parameter based transient models, 1-D physical-based coarse grain models, and 3-D CFD models are available. Current major system analysis codes either have no models or only 0-D models for thermal stratification and mixing, which can only give highly approximate results for simple cases. While 3-D CFD methods can be used to analyze simple configurations, these methods require very fine grid resolution to resolve thin substructures such as jets and wall boundaries. Due to prohibitive computational expenses for long transients in very large volumes, 3-D CFD simulations remain impractical for system analyses. For mixing in stably stratified large enclosures, UC Berkeley developed 1-D models basing on Zuber’s hierarchical two-tiered scaling analysis (HTTSA) method where the ambient fluid volume is represented by 1-D transient partial differential equations and substructures such as free or wall jets are modeled with 1-D integral models. This allows very large reductions in computational effort compared to 3-D CFD modeling. This paper will present an overview on important thermal mixing and stratification phenomena in large enclosures for different reactors, major modeling methods and their advantages and limits, potential paths to improve simulation capability and reduce analysis uncertainty in this area for advanced reactor system analysis tools.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Electrostatic Barriers to Nanoparticle Accessibility of a Porous Matrix

Translocation from one cavity to another through a narrow constriction (i.e., a “hole”) represents the fundamental elementary process underlying hindered mass transport of nanoparticles and macromolecules within many natural and synthetic porous materials, including intracellular environments. This process is complex and may be influenced by long-range (e.g., electrostatic) particle–wall interactions, transient adsorption/desorption, surface diffusion, and hydrodynamic effects. In this study, we used a three-dimensional (3D) tracking method to explicitly visualize the process of nanoparticle diffusion within periodic porous nanostructures, where electrostatic interactions were mediated via ionic strength. The effects of electrostatic interactions on nanoparticle transport were surprisingly large. For example, an increase in the Debye length of only a few nanometers (in a material with a hole diameter of ~100 nm) increased the mean cavity escape time 3-fold. A combination of computational and experimental analyses indicated that this hindered cavity escape was due to an electrostatic energy barrier in the region of the hole, which was quantitatively explained using DLVO theory. These findings explicitly demonstrate that the cavity escape process was barrier-limited and dominated by electrostatic effects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Resection Followed by Stereotactic Radiosurgery to Resection Cavity for Intracranial Metastases

Purpose: In patients who undergo resection of central nervous system metastases, whole brain radiotherapy (WBRT) is added to reduce the rates of recurrence and neurologic death. However, the risk of late neurotoxicity has led many patients to decline WBRT. We offered adjuvant stereotactic radiosurgery (SRS) or stereotactic radiotherapy (SRT) as an alternative to select patients with resected brain metastases. Methods and Materials: We performed a retrospective review of patients who underwent brain metastasis resection followed by SRS/SRT. WBRT was administered only as salvage treatment. Patients had one to four brain metastases. The dose was 15-18 Gy for SRS and 22-27.5 Gy in four to six fractions for SRT. Target margins were typically expanded by 1 mm for rigid immobilization and 3 mm for mask immobilization. SRS/SRT involved the use of linear accelerator radiosurgery using the IMRT 21EX or Helical Tomotherapy unit. Results: Between December 1999 and January 2007, 30 patients diagnosed with intracranial metastases were treated with resection followed by SRS or SRT to the resection cavity. Of the 30 patients, 4 (13.3%) developed recurrence in the resection cavity, and 19 (63%) developed recurrences in new intracranial sites. The actuarial 12-month survival rate was 82% for local recurrence-free survival, 31% for freedom from new brain metastases, 67% for neurologic deficit-free survival, and 51% for overall survival. Salvage WBRT was performed in 14 (47%) of the 30 patients. Conclusion: Our results suggest that for patients with newly diagnosed brain metastases treated with surgical resection, postoperative SRS/SRT to the resection cavity is a feasible option. WBRT can be reserved as salvage treatment with acceptable neurologic deficit-free survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technical Note: Multipurpose CT, ultrasound, and MRI breast phantom for use in radiotherapy and minimally invasive interventions

Purpose: To develop a multipurpose gel-based breast phantom consisting of a simulated tumor with realistic imaging properties in CT, ultrasound and MRI, or a postsurgical cavity on CT. Applications for the phantom include: deformable image registration (DIR) quality assurance (QA), autosegmentation validation, and localization testing and training for minimally invasive image-guided procedures such as those involving catheter or needle insertion. Methods: A thermoplastic mask of a typical breast patient lying supine was generated and then filled to make an array of phantoms. The background simulated breast tissue consisted of 32.4 g each of ballistic gelatin (BG) powder and Metamusil™ (MM) dissolved in 800 ml of water. Simulated tumors were added using the following recipe: 12 g of barium sulfate (1.4% v/v) plus 0.000 14 g copper sulfate plus 0.7 g of MM plus 7.2 g of BG all dissolved in 75 ml of water. The phantom was evaluated quantitatively in CT by comparing Hounsfield units (HUs) with actual breast tissue. For ultrasound and MRI, the phantoms were assessed based on subjective image quality and signal-difference to noise (SDNR) ratio, respectively. The stiffness of the phantom was evaluated based on ultrasound elastography measurements to yield an average Young’s modulus. In addition, subjective tactile assessment of phantom was performed under needle insertion. Results: The simulated breast tissue had a mean background value of 24 HU on CT imaging, which more closely resembles fibroglandular tissue (40 HU) as opposed to adipose (−100 HU). The tumor had a mean CT number of 45 HU, which yielded a qualitatively realistic image contrast relative to the background either as an intact tumor or postsurgical cavity. The tumor appeared qualitatively realistic on ultrasound images, exhibiting hypoechoic characteristics compared to background. On MRI, the tumor exhibited a SDNR of 3.7. The average Young’s modulus was computed to be 15.8 ± 0.7 kPa (1 SD). Conclusions: We have developed a process to efficiently and inexpensively produce multipurpose breast phantoms containing simulated tumors visible on CT, ultrasound, and MRI. The phantoms have been evaluated for image quality and elasticity and can serve as a medium for DIR QA, autosegmentation QA, and training for minimally invasive procedures.

60 APPLIED LIFE SCIENCES↗

Initial Efficacy Results of RTOG 0319: Three-Dimensional Conformal Radiation Therapy (3D-CRT) Confined to the Region of the Lumpectomy Cavity for Stage I/ II Breast Carcinoma

Purpose: This prospective study (Radiation Therapy Oncology Group 0319) examines the use of three-dimensional conformal external beam radiotherapy (3D-CRT) to deliver accelerated partial breast irradiation (APBI). Initial data on efficacy and toxicity are presented. Methods and Materials: Patients with Stage I or II breast cancer with lesions {<=}3 cm, negative margins and with {<=}3 positive nodes were eligible. The 3D-CRT was 38.5 Gy in 3.85 Gy/fraction delivered 2x/day. Ipsilateral breast, ipsilateral nodal, contralateral breast, and distant failure (IBF, INF, CBF, DF) were estimated using the cumulative incidence method. Mastectomy-free, disease-free, and overall survival (MFS, DFS, OS) were recorded. The National Cancer Institute Common Terminology Criteria for Adverse Events, version 3, was used to grade acute and late toxicity. Results: Fifty-eight patients were entered and 52 patients are eligible and evaluable for efficacy. The median age of patients was 61 years with the following characteristics: 46% tumor size <1 cm; 87% invasive ductal histology; 94% American Joint Committee on Cancer Stage I; 65% postmenopausal; 83% no chemotherapy; and 71% with no hormone therapy. Median follow-up is 4.5 years (1.7-4.8). Four-year estimates (95% CI) of efficacy are: IBF 6% (0-12%) [4% within field (0-9%)]; INF 2% (0-6%); CBF 0%; DF 8% (0-15%); MFS 90% (78-96%); DFS 84% (71-92%); and OS 96% (85-99%). Only two (4%) Grade 3 toxicities were observed. Conclusions: Initial efficacy and toxicity using 3D-CRT to deliver APBI appears comparable to other experiences with similar follow-up. However, additional patients, further follow-up, and mature Phase III data are needed to evaluate the extent of application, limitations, and value of this particular form of APBI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗