Search NASA⌕ Search

SEARCH · Search NASA

Results for “comparisons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

A quantitative comparison of the fingerprint of twinned microstructures through surface and three-dimensional techniques

Assessing the fingerprint of a material’s microstructure is key for supporting materials design. With the emergence of a wide range of 3D characterization techniques, it is critical to understand the main differences in fingerprints reconstructed from 2D and 3D datasets. To this end, we introduce a graph-based microstructure reconstruction framework that enables structural comparisons of twin domain networks in high purity Ti using 3D and 2D electron backscatter diffraction. Insights into the structure of the twin networks are facilitated by combining statistical analysis of twin crystallography with visual and graphical analysis of the novel graph abstractions of the twins. We demonstrate that compared to 3D reconstructions, conventional 2D views of twinning miss key aspects of the microstructure including the high interconnectivity of domains into networks that span the full reconstruction volume. The reduced cross-grain and in-grain twin connectivity typically observed in 2D has notable implications on our understanding of how twinning mediates the plastic response of microstructures and how twin networks evolve. It is thus clear that 3D characterization is critical for accurately inferring both twin network morphologies as well as the key unit processes facilitating network formation.

36 MATERIALS SCIENCE↗

Comparison of short-range order in irradiated dysprosium titanates

Abstract The structural response of Dy 2 TiO 5 oxide under swift heavy ion irradiation (2.2 GeV Au ions) was studied over a range of structural length scales utilizing neutron total scattering experiments. Refinement of diffraction data confirms that the long-range orthorhombic structure is susceptible to ion beam-induced amorphization with limited crystalline fraction remaining after irradiation to 8 × 10 12 ions/cm 2 . In contrast, the local atomic arrangement, examined through pair distribution function analysis, shows only subtle changes after irradiation and is still described best by the original orthorhombic structural model. A comparison to Dy 2 Ti 2 O 7 pyrochlore oxide under the same irradiation conditions reveals a different behavior: while the dysprosium titanate pyrochlore is more radiation resistant over the long-range with smaller degree of amorphization as compared to Dy 2 TiO 5 , the former involves more local atomic rearrangements, best described by a pyrochlore-to-weberite-type transformation. These results highlight the importance of short-range and medium-range order analysis for a comprehensive description of radiation behavior.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis of 85Kr: a comparison at the 10-14 level using micro-liter samples

The isotopic abundance of 85Kr in the atmosphere, currently at the level of 10211, has increased by orders of magnitude since the dawn of nuclear age. With a half-life of 10.76 years, 85Kr is of great interest as tracers for environmental samples such as air, groundwater and ice. Atom Trap Trace Analysis (ATTA) is an emerging method for the analysis of rare krypton isotopes at isotopic abundance levels as low as 10214 using krypton gas samples of a few micro-liters. Both the reliability and reproducibility of the method are examined in the present study by an inter-comparison among different instruments. The 85Kr/Kr ratios of 12 samples, in the range of 10213 to 10210, are measured independently in three laboratories: a low-level counting laboratory in Bern, Switzerland, and two ATTA laboratories, one in Hefei, China, and the other in Argonne, USA. The results are in agreement at the precision level of 5%.

MASS SPECTROMETRY↗

Complexation of NpO2+ with N-methyl-iminodiacetic Acid: in Comparison with Iminodiacetic and Dipicolinic Acids

Complexation of Np(V) with N-methyl-iminodiacetic acid (MIDA) in 1 M NaClO{sub 4} solution was studied with multiple techniques including potentiometry, spectrophotometry, and microcalorimetry. The 1:2 complex, NpO{sub 2}(MIDA){sub 2}{sup 3-} was identified for the first time in aqueous solution. The correlation between its optical absorption properties and symmetry was discussed, in comparison with Np(V) complexes with two structurally related nitrilo-dicarboxylic acids, iminodiacetic acid (IDA) and dipicolinic acid (DPA). The order of the binding strength (DPA > MIDA > IDA) is explained by the difference in the structural and electronic properties of the ligands. In general, the nitrilo-dicarboxylates form stronger complexes with Np(V) than oxy-dicarboxylates due to a much more favorable enthalpy of complexation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

How reliable are efficiency measurements of perovskite solar cells? The first inter-comparison, between two accredited and eight non-accredited laboratories

Perovskite materials have generated significant interest from academia and industry as a potential component in next-generation, high-efficiency, low-cost, photovoltaic (PV) devices. The record efficiency reported for perovskite solar cells has risen rapidly, and is now more than 22%. However, due to their complex dynamic behaviour, the process of measuring the efficiency of perovskite solar cells appears to be much more complicated than for other technologies. It has long been acknowledged that this is likely to greatly reduce the reliability of reported efficiency measurements, but the quantitative extent to which this occurs has not been determined. To investigate this, we conduct the first major inter-comparison of this PV technology. The participants included two labs accredited for PV performance measurement (CSIRO and NREL) and eight PV research laboratories. We find that the inter-laboratory measurement variability can be almost ten times larger for a slowly responding perovskite cell than for a control silicon cell. We show that for such a cell, the choice of measurement method, far more so than measurement hardware, is the single-greatest cause for this undesirably large variability. We provide recommendations for identifying the most appropriate method for a given cell, depending on its stabilization and degradation behaviour. Moreover, the results of this study suggest that identifying a consensus technique for accurate and meaningful efficiency measurements of perovskite solar cells will lead to an immediate improvement in reliability. This, in turn, should assist device researchers to correctly evaluate promising new materials and fabrication methods, and further boost the development of this technology.

14 SOLAR ENERGY↗

The levelized cost of exergy: a technoeconomic framework for energy system comparison

While the levelized costs of electricity and heat have been quantified before, these two metrics cannot be directly compared, due to the different exergy content of heat and work. To address this, we develop a levelized cost of exergy (LCOEx) framework that enables direct comparisons between energy sources and processes. We find that moderate- and high-grade heat have an LCOEx that is comparable to electricity (5–10 ¢ per kWh ex ), while low-grade heat sources have much higher LCOEx values (>50 ¢ per kWh ex ). The LCOEx of a system's output is affected by (i) the LCOEx of the system input, (ii) the CAPEX of the system, and (iii) the exergetic efficiency of the system. We use our framework to identify which processes are already achieved with relatively high cost effectiveness (production of fuels, hydrogen, and ammonia) and which have room for improvement (dehumidification, food production).

08 HYDROGEN↗

Comparison of SiC MOSFET‐based and GaN HEMT‐based high‐efficiency high‐power‐density 7.2 kW EV battery chargers

As two exemplary candidates of wide‐bandgap devices, SiC MOSFETs and GaN HEMTs are regarded as successors of Si devices in medium‐to‐high‐voltage (>1200 V) and low‐voltage (<650 V) domains, respectively, thanks to their excellent switching performance and thermal capability. With the introduction of 650 V SiC MOSFETs and GaN HEMTs, the two technologies are in direct competition in <650 V domains, such as Level 2 battery chargers for electric vehicles (EVs). This study applies 650 V SiC and GaN to two 240 VAC/7.2 kW EV battery chargers, respectively, aiming to provide a head‐to‐head comparison of these two devices in terms of overall efficiency, power density, thermal performance, and cost. The charger essentially is an indirect matrix converter with a dual‐active‐bridge stage handling the power factor correction and power delivery simultaneously. These two chargers utilise the same control strategy, varying the phase‐shift and switching frequency to cover the wide input range (80–260 VAC) and wide output range (200 V–450 VDC). Experimental results indicated that at the same efficiency level, the GaN charger is smaller, more efficient and cheaper, while the SiC charger has a better thermal performance.

Taylor, Allan↗

Planck intermediate results. XXI. Comparison of polarized thermal emission from Galactic dust at 353 GHz with interstellar polarization in the visible

The Planck survey provides unprecedented full-sky coverage of the submillimetre polarized emission from Galactic dust. In addition to the information on the direction of the Galactic magnetic field, this also brings new constraints on the properties of dust. The dust grains that emit the radiation seen by Planck in the submillimetre also extinguish and polarize starlight in the visible. Comparison of the polarization of the emission and of the interstellar polarization on selected lines of sight probed by stars provides unique new diagnostics of the emission and light scattering properties of dust, and therefore of the important dust model parameters, composition, size, and shape. Using ancillary catalogues of interstellar polarization and extinction of starlight, we obtain the degree of polarization, p V , and the optical depth in the V band to the star, τ V . Toward these stars we measure the submillimetre polarized intensity, P S , and total intensity, I S , in the Planck 353 GHz channel. We compare the column density measure in the visible, E ( B - V ), with that inferred from the Planck product map of the submillimetre dust optical depth and compare the polarization direction (position angle) in the visible with that in the submillimetre. For those lines of sight through the diffuse interstellar medium with comparable values of the estimated column density and polarization directions close to orthogonal, we correlate properties in the submillimetre and visible to find two ratios, R S/V = ( P S /I S )/( p V /τ V ) and R P/p = P S / p V , the latter focusing directly on the polarization properties of the aligned grain population alone. We find R S/V = 4.2, with statistical and systematic uncertainties 0.2 and 0.3, respectively, and R P/p = 5.4 MJy sr -1 , with uncertainties 0.2 and 0.3 MJy sr -1 , respectively. Our estimate of R S/V is compatible with predictions based on a range of polarizing dust models that have been developed for the diffuse interstellar medium. This estimate provides new empirical validation of many of the common underlying assumptions of the models, but is not yet very discriminating among them. However, our estimate of R P/p is not compatible with predictions, which are too low by a factor of about 2.5. This more discriminating diagnostic, R P/p , indicates that changes to the optical properties in the models of the aligned grain population are required. These new diagnostics, together with the spectral dependence in the submillimetre from Planck , will be important for constraining and understanding the full complexity of the grain models, and for interpreting the Planck thermal dust polarization and refinement of the separation of this contamination of the cosmic microwave background.

79 ASTRONOMY AND ASTROPHYSICS↗

Systematic comparison between line integrated densities measured with interferometry and polarimetry at JET

A systematic comparison between the line integrated electron density derived from interferometry and polarimetry at JET has been carried out. For the first time the reliability of the measurements of the Cotton-Mouton effect has been analyzed for a wide range of main plasma parameters and the possibility to evaluate the electron density directly from polarimetric data has been studied. The purpose of this work is to recover the interferometric data with the density derived from the measured Cotton-Mouton effect, when the fringe jump phenomena occur. The results show that the difference between the line integrated electron density from interferometry and polarimetry is with one fringe (1.143x10{sup 19} m{sup -2}) for more than 90% of the cases. It is possible to consider polarimetry as a satisfactory alternative method to interferometry to measure the electron density and it could be used to recover interferometric signal when a fringe jumps occurs, preventing difficulties for the real-time control of many experiments at the JET machine.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-Time Parameter Estimation Method Applied to a MIMO Process and its Comparison with an Offline Identification Method

An experiment based method is proposed for parameter estimation of a class of linear multivariable systems. The method was applied to a pressure-level control process. Experimental time domain input/output data was utilized in a gray-box modeling approach. Prior knowledge of the form of the system transfer function matrix elements is assumed to be known. Continuous-time system transfer function matrix parameters were estimated in real-time by the least-squares method. Simulation results of experimentally determined system transfer function matrix compare very well with the experimental results. For comparison and as an alternative to the proposed real-time estimation method, we also implemented an offline identification method using artificial neural networks and obtained fairly good results. The proposed methods can be implemented conveniently on a desktop PC equipped with a data acquisition board for parameter estimation of moderately complex linear multivariable systems.

99 GENERAL AND MISCELLANEOUS↗

Comparison of photoexcited p-InAs THz radiation source with conventional thermal radiation sources

P-type InAs excited by ultrashort optical pulses has been shown to be a strong emitter of terahertz radiation. In a direct comparison between a p-InAs emitter and conventional thermal radiation sources, we demonstrate that under typical excitation conditions p-InAs produces more radiation below 1.2 THz than a globar. By treating the globar as a blackbody emitter we calibrate a silicon bolometer which is used to determine the power of the p-InAs emitter. The emitted terahertz power was found to be 98{+-}10 nW in this experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison theory of Lorentzian distance with applications to spacelike hypersurfaces

In this paper we summarize some comparison results for the Lorentzian distance function in spacetimes, with applications to the study of the geometric analysis of the Lorentzian distance on spacelike hypersurfaces. In particular, we will consider spacelike hypersufaces whose image under the immersion is bounded in the ambient spacetime and derive sharp estimates for the mean curvature of such hypersurfaces under appropriate hypotheses on the curvature of the ambient spacetime. The results in this paper are part of our recent work, where complete details and further related results may be found.

79 ASTRONOMY AND ASTROPHYSICS↗

Evolution of the bounded magnetized jet and comparison with Helimak experiments

Magnetized jets are important features of many systems of physical interest. To date, most interest has focused on solar and space physics and astrophysical applications, and hence the unbounded magnetized jet, and its cousin, the unbounded magnetized wake, have received the most attention. This work presents calculations of a bounded, magnetized jet for a laboratory experiments in the Helimak device [K. W. Gentle and H. He, Plasma Sci. Technol. 10, 284 (2008)]. The Helimak device has a toroidal magnetic field with a controlled velocity flow that represents jets in bounded systems. Experimental and theoretical features include three spatial dimensions, the inclusion of resistivity and viscosity, and the presence of no-slip walls. The results of the linearized model are computed with a Chebyshev-{tau} algorithm. The bounding walls stabilize the ideal varicose mode found in unbounded magnetized jets. The ideal sinuous mode persists in the bounded system. A comparison theorem is proved showing that two-dimensional modes are more unstable than the corresponding three-dimensional modes for any given set of system parameters. This result is a generalization of the hydrodynamic Squires theorem. An energy-stress theorem indicates that the Maxwell stress is crucial for the growth of the instability. The results of the analysis are consistent with the observed plasma fluctuations with in the limits of using a simple model for the more complex measured jet velocity flow profile. The working gas is singly ionized argon and the jet velocity profile is accurately measured with Doppler shift spectroscopy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison between experiment and simulation for argon inductively coupled plasma

In order to include the nonlocal characteristics of electrons and investigate the inductively coupled plasma (ICP) resources more completely, we have developed a hybrid Monte Carlo (MC)/fluid hybrid model and calculated the axial and radial distributions of electron density, electron temperature, plasma potential, and electron energy distribution functions (EEDFs) of Ar discharge in a planar ICP. Furthermore, to make the model more practical, we still incorporate the effects of metastable atoms, whose sets of rate coefficients and density are, respectively, calculated through the electron MC part and fluid module. Besides, the corresponding Langmuir probe measurements are used to compare these data to validate the simulated results. Under all the selected discharge powers and pressures, the theoretically simulated and experimentally measured quantity profiles agree reasonably with each other, embodied in the generally identical magnitude ranges and spatial distributions. Furthermore, the interpretations about their detailed differences are given, which are based on the designs of both experimental schematic and model configuration. The analysis implements that the inclusions of electron-electron collision and a neutral density distribution into the hybrid model are likely to improve the comparison between the model predictions and experiment diagnostics. Furthermore, the evolution of plasma parameters and EEDFs with discharge conditions is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electromagnetic Modelling of Dielectric Loads in front of an ICRH ITER Array using TOPICA and HFSS codes for comparison

The antenna scattering (S-matrix) or impedance matrix at location where the antenna is connected to the power system is of crucial importance to assess compliance with power handling requirements and to design the tuning-and-matching system. The electrical behaviour of an Ion Cyclotron Resonance Heating (ICRH) ITER antenna in front of an infinite isotropic load was assessed numerically using the HFSSR and TOPICA codes for comparison. The calculations were performed at 45 MHz, for various thicknesses of the vacuum layer, various relative permittivities {epsilon}' for dielectric medium without losses ({epsilon}'' = 0),{epsilon}' ranging from 81 to 1000 and for various conductive losses {epsilon}'' = {sigma}/{epsilon}{sub 0}{center_dot}{omega}, for electrolyte medium ({epsilon}' = 81),{epsilon}'' ranging from 0 to 1000. The numerical results obtained with TOPICA and HFSS codes show a good overall agreement in case of vacuum, dielectric and electrolyte mediums. The best absorption of the fast magneto-sonic (Alfven) waves into the loads (i.e. the minimum of the module of antenna input reflection coefficient S11) is obtained around {epsilon}' = 400 for dielectric medium and around {epsilon}'' = 400 for electrolyte case.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ITER ICRF Antenna Reduced-Scale Mock-up EM Simulations and Comparisons with the Measurements

A reduced-scale mock-up of one ITER ICRF antenna triplet has been recently built, featuring the optimized front-end geometry, an optimized 4-port junction and the implementation of a service stub. Provision is made to adapt the frequency response of the antenna by acting on the 4-port junction arms lengths, the service stub length as well as the position of its inclusion in the circuit. Variable antenna loading is achieved by moving a salted water tank in front of the antenna. A summary of the first measurements carried out on this mockup is reported in a companion paper. The EM simulations of the mock-up are done with CST Microwave Studio registered. The geometry of the mock-up is converted from a CAD file and all essential details are included in the model. S parameters of the mock-up are calculated in a large frequency range covering the ITER ICRF antenna frequency band for different geometries of the mock-up and distances to the load. Results of the simulations and systematic comparisons with the measurements are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗