Search NASA⌕ Search

SEARCH · Search NASA

Results for “data collection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Bay Ridge Gardens - Mixed-Humid Affordable Multifamily Housing Deep Energy Retrofit

Under this project, Newport Partners (as part of the BA-PIRC research team) evaluated the installation, measured performance, and cost-effectiveness of efficiency upgrade measures for a tenant-in-place DER at the Bay Ridge multifamily (MF) development in Annapolis, Maryland. The design and construction phase of the Bay Ridge project was completed in August 2012. This report summarizes system commissioning, short-term test results, utility bill data analysis, and analysis of real-time data collected over a one-year period after the retrofit was complete. The Bay Ridge project is comprised of a 'base scope' retrofit which was estimated to achieve a 30%+ savings (relative to pre-retrofit) on 186 apartments, and a 'DER scope' which was estimated to achieve 50% savings (relative to pre-retrofit) on a 12-unit building. The base scope was applied to the entire apartment complex, except for one 12-unit building which underwent the DER scope. A wide range of efficiency measures was applied to pursue this savings target for the DER building, including improvements/replacements of mechanical equipment and distribution systems, appliances, lighting and lighting controls, the building envelope, hot water conservation measures, and resident education. The results of this research build upon the current body of knowledge of multifamily retrofits. Towards this end, the research team has collected and generated data on the selection of measures, their estimated performance, their measured performance, and risk factors and their impact on potential measures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bay Ridge Gardens – Mixed Humid Affordable Multifamily Housing Deep Energy Retrofit: Annapolis, Maryland - Building America Case Study: Whole-House Solutions for Existing Homes [Fact Sheet]

Under this project, Newport Partners (as part of the BA-PIRC research team) evaluated the installation, measured performance, and cost-effectiveness of efficiency upgrade measures for a tenant-in-place DER at the Bay Ridge multifamily (MF) development in Annapolis, Maryland. The design and construction phase of the Bay Ridge project was completed in August 2012. This report summarizes system commissioning, short-term test results, utility bill data analysis, and analysis of real-time data collected over a one-year period after the retrofit was complete. The Bay Ridge project is comprised of a "base scope" retrofit which was estimated to achieve a 30%+ savings (relative to pre-retrofit) on 186 apartments, and a "DER scope" which was estimated to achieve 50% savings (relative to pre-retrofit) on a 12-unit building. The base scope was applied to the entire apartment complex, except for one 12-unit building which underwent the DER scope. A wide range of efficiency measures was applied to pursue this savings target for the DER building, including improvements/replacements of mechanical equipment and distribution systems, appliances, lighting and lighting controls, the building envelope, hot water conservation measures, and resident education. The results of this research build upon the current body of knowledge of multifamily retrofits. Towards this end, the research team has collected and generated data on the selection of measures, their estimated performance, their measured performance, and risk factors and their impact on potential measures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Disaggregating Hot Water Use and Predicting Hot Water Waste in Five Test Homes

While it is important to make the equipment (or 'plant') in a residential hot water system more efficient, the hot water distribution system also affects overall system performance and energy use. Energy wasted in heating water that is not used is estimated to be on the order of 10 to 30 percent of total domestic hot water (DHW) energy use. This field monitoring project installed temperature sensors on the distribution piping (on trunks and near fixtures) and programmed a data logger to collect data at 5 second intervals whenever there was a hot water draw. This data was used to assign hot water draws to specific end uses in the home as well as to determine the portion of each hot water that was deemed useful (i.e., above a temperature threshold at the fixture). Five houses near Syracuse NY were monitored. Overall, the procedures to assign water draws to each end use were able to successfully assign about 50% of the water draws, but these assigned draws accounted for about 95% of the total hot water use in each home. The amount of hot water deemed as useful ranged from low of 75% at one house to a high of 91% in another. At three of the houses, new water heaters and distribution improvements were implemented during the monitoring period and the impact of these improvements on hot water use and delivery efficiency were evaluated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fast Charging Electric Vehicle Research & Development Project

The research and development project supported the engineering, design and implementation of on-road Electric Vehicle (“EV”) charging technologies. It included development of potential solutions for DC fast chargers (“DCFC”) capable of converting high voltage AC power to the DC power required by EVs. Additional development evaluated solutions related to the packaging of power electronic components and enclosure design, as well as for the design and evaluation of EV charging stations. Research compared different charging technologies to identify optimum applications in a municipal fleet. This project collected EV usage data and generated a report demonstrating that EVs, when supported by adequate charging infrastructure, are capable of replacing traditional internal combustion vehicles in many municipal applications. The project’s period of performance has demonstrated various methods of incorporating EVs into a municipal environment, and has identified three general categories for EV applications: Short Commute: Defined as EVs performing in limited duration, routine commutes. - Long Commute: Defined as tasks that require EVs to operate in longer daily mileage patterns. - Critical Needs: Defined as the need for EVs to be ready at every moment for indefinite periods. Together, the City of Charlottesville, VA (the “City”) and Aker Wade Power Technologies, LLC (“Aker Wade”) concluded that the EV has a viable position in many municipal fleets but with limited recommendation for use in Critical Needs applications such as Police fleets. The report also documented that, compared to internal combustion vehicles, BEVs have lower vehicle-related greenhouse gas (“GHG”) emissions and contribute to a reduction of air pollution in urban areas. The enhanced integration of EVs in a municipal fleet can result in reduced demand for imported oil and reduced municipal operating costs. The conclusions indicated in the project’s Engineering Report (see Attachment A) are intended to assist future implementation of electric vehicle technology. They are based on the cited research and on the empirical data collected and presented. The report is not expected to represent the entire operating conditions of any of the equipment under consideration within this project, and tested equipment may operate differently under other conditions.

42 ENGINEERING↗

Bay Ridge Gardens - Mixed Humid Affordable Multifamily Housing Deep Energy Retrofit

Under this project, Newport Partners (as part of the BA-PIRC research team) evaluated the installation, measured performance, and cost effectiveness of efficiency upgrade measures for a tenant-in-place deep energy retrofit (DER) at the Bay Ridge multifamily development in Annapolis, Maryland. This report summarizes system commissioning, short-term test results, utility bill data analysis, and analysis of real-time data collected over a one-year period after the retrofit was complete. The Bay Ridge project is comprised of a "base scope" retrofit which was estimated to achieve a 30%+ savings (relative to pre-retrofit) on 186 apartments, and a "DER scope" which was estimated to achieve 50% savings (relative to pre-retrofit) on a 12-unit building. A wide range of efficiency measures was applied to pursue this savings target for the DER building, including improvements/replacements of mechanical equipment and distribution systems, appliances, lighting and lighting controls, the building envelope, hot water conservation measures, and resident education. The results of this research build upon the current body of knowledge of multifamily retrofits. Towards this end, the research team has collected and generated data on the selection of measures, their estimated performance, their measured performance, and risk factors and their impact on potential measures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Disaggregating Hot Water Use and Predicting Hot Water Waste in Five Test Homes

While it is important to make the equipment (or "plant") in a residential hot water system more efficient, the hot water distribution system also affects overall system performance and energy use. Energy wasted in heating water that is not used is estimated to be on the order of 10%-30% of total domestic hot water (DHW) energy use. This field monitoring project installed temperature sensors on the distribution piping (on trunks and near fixtures) in five houses near Syracuse, NY, and programmed a data logger to collect data at 5 second intervals whenever there was a hot water draw. This data was used to assign hot water draws to specific end uses in the home as well as to determine the portion of each hot water that was deemed useful (i.e., above a temperature threshold at the fixture). Overall, the procedures to assign water draws to each end use were able to successfully assign about 50% of the water draws, but these assigned draws accounted for about 95% of the total hot water use in each home. The amount of hot water deemed as useful ranged from low of 75% at one house to a high of 91% in another. At three of the houses, new water heaters and distribution improvements were implemented during the monitoring period and the impact of these improvements on hot water use and delivery efficiency were evaluated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CSULA Hydrogen Refueling Facility Performance Evaluation and Optimization

Throughout its history, Cal State LA has been in the forefront of advanced energy and transportation technologies. The station is located at the intersection of two major highways in Los Angeles region and has a convenient access. It is capable of producing up to 60 kg/day and can fuel 15-20 vehicles per day. Cal State LA had partnered with DOE to establish a robust station operation and performance data collection program. This consisted of equipping the station with additional instrumentation and collecting fueling performance data for several years. The data was further furnished to NREL for processing and agglomeration with data from other stations. In addition to fueling, maintenance and failure events were shared as well as hydrogen purity reports. The station has also undergone several upgrades in fueling protocols and hardware for improved performance and code compliance.

08 HYDROGEN↗

Actionable Capability for Social and Economic Systems (ACSES)

The foundation of the Actionable Capability for Social and Economic Systems (ACSES) project is a useful regional-scale social-simulation system. This report is organized into five chapters that describe insights that were gained concerning the five key feasibility questions pertaining to such a system: (1) Should such a simulation system exist, would the current state of data sets or collectible data sets be adequate to support such a system? (2) By comparing different agent-based simulation systems, is it feasible to compare simulation systems and select one appropriate for a given application with agents behaving according to modern social theory rather than ad hoc rule sets? (3) Provided that a selected simulation system for a region of interest could be constructed, can the simulation system be updated with new and changing conditions so that the universe of potential outcomes are constrained by events on the ground as they evolve? (4) As these results are constrained by evolving events on the ground, is it feasible to still generate surprise and emerging behavior to suggest outcomes from novel courses of action? (5) As these systems may for the first time require large numbers (hundreds of millions) of agents operating with complexities demanded of modern social theories, can results still be generated within actionable decision cycles?

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Real-time fracture monitoring in Engineered Geothermal Systems with seismic waves

As proposed, the main effort in this project is the development of software capable of performing real-time monitoring of micro-seismic activity recorded by an array of sensors deployed around an EGS. The main milestones are defined by the development of software to perform the following tasks: • Real-time micro-earthquake detection and location • Real-time detection of shear-wave splitting • Delayed-time inversion of shear-wave splitting These algorithms, which are discussed in detail in this report, make possible the automatic and real-time monitoring of subsurface fracture systems in geothermal fields from data collected by an array of seismic sensors. Shear wave splitting (SWS) is parameterized in terms of the polarization of the fast shear wave and the time delay between the fast and slow shear waves, which are automatically measured and stored. The measured parameters are then combined with previously measured SWS parameters at the same station and used to invert for the orientation (strike and dip) and intensity of cracks under that station. In addition, this grant allowed the collection of seismic data from several geothermal regions in the US (Coso) and Iceland (Hengill) to use in the development and testing of the software.

15 GEOTHERMAL ENERGY↗

Final technical report

As proposed, the main effort in this project is the development of software capable of performing real-time monitoring of micro-seismic activity recorded by an array of sensors deployed around an EGS. The main milestones are defined by the development of software to perform the following tasks: • Real-time micro-earthquake detection and location • Real-time detection of shear-wave splitting • Delayed-time inversion of shear-wave splitting These algorithms, which are discussed in detail in this report, make possible the automatic and real-time monitoring of subsurface fracture systems in geothermal fields from data collected by an array of seismic sensors. Shear wave splitting (SWS) is parameterized in terms of the polarization of the fast shear wave and the time delay between the fast and slow shear waves, which are automatically measured and stored. The measured parameters are then combined with previously measured SWS parameters at the same station and used to invert for the orientation (strike and dip) and intensity of cracks under that station. In addition, this grant allowed the collection of seismic data from several geothermal regions in the US (Coso) and Iceland (Hengill) to use in the development and testing of the software.

15 GEOTHERMAL ENERGY↗

From Qualitative to Quantitative AOP: A Case Study of Neurodegeneration

Adverse outcome pathways (AOPs) include a sequence of events that connect a molecular-level initiating event with an adverse outcome at the cellular level for human health endpoints, or at the population level for ecological endpoints. When there is enough quantitative understanding of the relationships between key events in an AOP, a mathematical model may be developed to connect key events in a quantitative AOP (qAOP). Ideally, a qAOP will reduce the time and resources spent for chemical toxicity testing and risk assessment and enable the extrapolation of data collected at the molecular-level by in vitro assays, for example, to predict whether an adverse outcome may occur. Here, we review AOPs in the AOPWiki, an AOP repository, to determine best practices that would facilitate conversion from AOP to qAOP. Then, focusing on a particular case study, acetylcholinesterase inhibition leading to neurodegeneration, we describe specific methods and challenges. Examples of challenges include the availability and collection of quantitative data amenable to model development, the lack of studies that measure multiple key events, and model accessibility or transferability across platforms. We conclude with recommendations for improving key event and key event relationship descriptions in the AOPWiki that facilitate the transition of qualitative AOPs to qAOPs.

Sinitsyn, Dennis↗

Search for Very High-energy Gamma Rays from the Northern Fermi Bubble Region with HAWC

We present a search for very high-energy gamma-ray emission from the Northern Fermi Bubble region using data collected with the High Altitude Water Cherenkov gamma-ray observatory. The size of the data set is 290 days. No significant excess is observed in the Northern Fermi Bubble region, so upper limits above 1 TeV are calculated. The upper limits are between 3×10{sup −7} GeV cm{sup −2} s{sup −1} sr{sup −1} and 4×10{sup −8} GeV cm{sup −2} s{sup −1} sr{sup −1}. The upper limits disfavor a proton injection spectrum that extends beyond 100 TeV without being suppressed. They also disfavor a hadronic injection spectrum derived from neutrino measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

Science subsystem

Instrumentation of science subsystem of Mariner- Mars 1964 mission - data collection instruments and data processing

SPACECRAFT INSTRUMENTATION↗

Earth Observatory Satellite system definition study. Report 5: System design and specifications. Volume 5: Specification for EROS operations control center

The functional, performance, and design requirements for the Operations Control Center (OCC) of the Earth Observatory Satellite (EOS) system are presented. The OCC controls the operations of the EOS satellite to acquire mission data consisting of: (1) thematic mapper data, (2) multispectral scanner data on EOS-A, or High Resolution Pointable Imager data on EOS-B, and (3) data collection system (DCS) data. The various inputs to the OCC are identified. The functional requirements of the OCC are defined. The specific systems and subsystems of the OCC are described and block diagrams are provided.

Source record↗

State criminal justice telecommunications (STACOM). Volume 1: Executive summary

Techniques for identifying user requirements and network designs for criminal justice networks on a state wide basis are discussed. Topics covered include: methods for determining data required; data collection and survey; data organization procedures, and methods for forecasting network traffic volumes. Developed network design techniques center around a computerized topology program which enables the user to generate least cost network topologies that satisfy network traffic requirements, response time requirements and other specified functional requirements. The developed techniques were applied in Texas and Ohio, and results of these studies are presented.

Fielding, J. E.↗

Development of a bedrest muscle stress apparatus

In attempting further to define the deleterious effects of spaceflight on the human body, measurement systems and techniques were devised to determine the loss of skeletal muscle strength and tone as a result of spaceflight exposure. In order to determine how the muscle degradation process progresses with time during nonuse, a system for measuring muscle stress during bedrest was developed. The Bedrest Muscle Stress Apparatus is configured to slip snugly over the foot board of a standard hospital bed. Data collected with this device correlated well with pre- and post-bedrest data collected with the original skeletal muscle stress apparatus.

Booher, C. R.↗

Post senescent grass canopy remote sensing

Analysis of in situ collected spectral reflectance data from a dormant or senescent grass canopy showed a direct relationship existed between spectral reflectance and biomass for the 0.50-0.80 micron spectral region. The data, collected four weeks after the end of the growing season, indicated that post senescent remote sensing of grass canopy biomass is possible and helps to elucidate the spectral contribution of recently dead vegetation in mixed live/dead canopy situations.

Tucker, C. J.↗

Dual charge-coupled device /CCD/, astronomical spectrometer and direct imaging camera. II - Data handling and control systems

The data collection system for the MASCOT (MIT Astronomical Spectrometer/Camera for Optical Telescopes) is described. The system relies on an RCA 1802 microprocessor-based controller, which serves to collect and format data, to present data to a scan converter, and to operate a device communication bus. A NOVA minicomputer is used to record and recall frame images and to perform refined image processing. The RCA 1802 also provides instrument mode control for the MASCOT. Commands are issued using STOIC, a FORTH-like language. Sufficient flexibility has been provided so that a variety of CCDs can be accommodated.

Dewey, D.↗