Emission-angle and polarization-rotation effects in the lensed CMB

Lensing of the CMB is an important effect, and is usually modelled by remapping the unlensed CMB fields by a lensing deflection. However the lensing deflections also change the photon path so that the emission angle is no longer orthogonal to the background last-scattering surface. We give the first calculation of the emission-angle corrections to the standard lensing approximation from dipole (Doppler) sources for temperature and quadrupole sources for temperature and polarization. We show that while the corrections are negligible for the temperature and E-mode polarization, additional large-scale B-modes are produced with a white spectrum that dominates those from post-Born field rotation (curl lensing). On large scales about one percent of the total lensing-induced B-mode amplitude is expected to be due to this effect. However, the photon emission angle does remain orthogonal to the perturbed last-scattering surface due to time delay, and half of the large-scale emission-angle B modes cancel with B modes from time delay to give a total contribution of about half a percent. While not important for planned observations, the signal could ultimately limit the ability of delensing to reveal low amplitudes of primordial gravitational waves. We also derive the rotation of polarization due to multiple deflections between emission and observation. The rotation angle is of quadratic order in the deflection angle, and hence negligibly small: polarization typically rotates by less than an arcsecond, orders of magnitude less than a small-scale image rotates due to post-Born field rotation (which is quadratic in the shear). The field-rotation B modes dominate the other effects on small scales.

79 ASTRONOMY AND ASTROPHYSICS↗

Errors in radial velocity variance from Doppler wind lidar

A high-fidelity lidar turbulence measurement technique relies on accurate estimates of radial velocity variance that are subject to both systematic and random errors determined by the autocorrelation function of radial velocity, the sampling rate, and the sampling duration. Our paper quantifies the effect of the volumetric averaging in lidar radial velocity measurements on the autocorrelation function and the dependence of the systematic and random errors on the sampling duration, using both statistically simulated and observed data. For current-generation scanning lidars and sampling durations of about 30 min and longer, during which the stationarity assumption is valid for atmospheric flows, the systematic error is negligible but the random error exceeds about 10%.

54 ENVIRONMENTAL SCIENCES↗

The effect of line damping, magneto-optics and parasitic light on the derivation of sunspot vector magnetic fields

The least square fitting of Stokes observations of sunspots using a Milne-Eddington-Unno model appears to lead, in many circumstances, to various inconsistencies such as anomalously large doppler widths and, hence, small magnetic fields which are significantly below those inferred solely from the Zeeman splitting in the intensity profile. It is found that the introduction of additional physics into the model such as the inclusion of damping wings and magneto-optic birefrigence significantly improves the fit to Stokes parameters. Model fits excluding the intensity profile, i.e., of both magnitude as well as spectral shape of the polarization parameters alone, suggest that parasitic light in the intensity profile may also be a source of inconsistencies. The consequences of the physical changes on the vector properties of the field derived from the Fe I lambda 6173 line for the 17 November 1975 spot as well as on the thermodynamic state are discussed. A Doppler width delta lambda (D) - 25mA is bound to be consistent with a low spot temperature and microturbulence, and a damping constant of a = 0.2.

Skumanich, A.↗

Utilizing Quantum Cascade Lasers for Ultranarrow Velocity Resolution and Quantum-State Selectivity in Molecular Beam Scattering and Spectroscopy

Here, we demonstrate the capability of a narrow linewidth quantum cascade laser (QCL) to selectively excite a very narrow velocity range of nitric oxide (σ ≤ 7(3) m/s) with a pure ro-vibrational quantum state. By implementing a counter-propagating geometry, the molecules are selectively excited according to the Doppler shift of the ro-vibrational transition frequency such that the velocity width associated with the excited molecules depends only on the QCL linewidth. We demonstrate a velocity distribution limited by the effective linewidth of our free-running QCL (Γ = 3.2 MHz). Our development provides a cost-effective, flexible approach to resolve quantum-state selective chemical dynamics with excellent velocity resolution in a wide variety of molecules with infrared-active transitions. This technique has been formulated to provide ultrahigh collisional energy resolution in molecular beams to delineate final quantum-state product pairs in studies of molecular collisions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Planck 2013 results. XXVII. Doppler boosting of the CMB: Eppur si muove

Our velocity relative to the rest frame of the cosmic microwave background (CMB) generates a dipole temperature anisotropy on the sky which has been well measured for more than 30 years, and has an accepted amplitude of v/c = 1.23 × 10 -3 , or v = 369 s -1 . In addition to this signal generated by Doppler boosting of the CMB monopole, our motion also modulates and aberrates the CMB temperature fluctuations (as well as every other source of radiation at cosmological distances). This is an order 10 -3 effect applied to fluctuations which are already one part in roughly 10 5 , so it is quite small. Nevertheless, it becomes detectable with the all-sky coverage, high angular resolution, and low noise levels of the Planck satellite. Here we report a first measurement of this velocity signature using the aberration and modulation effects on the CMB temperature anisotropies, finding a component in the known dipole direction, ( l,b ) = (264°,48°), of 384 km s -1 ± 78 km s -1 (stat.) ± 115 km s -1 (syst.). This is a significant confirmation of the expected velocity.

79 ASTRONOMY AND ASTROPHYSICS↗

The confrontation between general relativity and experiment

Experiments that test the foundations of gravitation theory in terms of the Einstein equivalence principle are discussed along with solar system tests of general relativity at the post-Newtonian level. These include classical (light-deflection, time delay and perihelion shift) tests as well as tests of the strong equivalence principle. The binary pulsar is discussed as an extra-solar-system gravitational testing ground, and attention is given to the multipolarity of the waves and the amount of radiation damping. The mass function, periastron shift, redshift-Doppler parameter and rate of change of the orbit period (Pb) of the binary pulsar are also considered, and it is suggested that the measurement of Pb represents the first observation of the effects of gravitational radiation.

Will, C. M.↗

Comparison of predicted engine core noise with current and proposed aircraft noise certification requirements

Predicted engine core noise levels for subsonic CTOL aircraft engines are compared with measured total aircraft noise levels and to current and proposed federal noise certification requirements. Comparisons are made at FAR-36 measuring stations and take into consideration both full and cutback power operations at takeoff. The spectral shape used for the prediction of core noise is identified as the spectral envelope, with a peak at 400 Hz which is assumed to be shifted in flight by a Doppler shift in frequency. Preceived noise levels are computed for appropriate engine power settings at desired flight conditions, and reductions in sideline noise levels are made to account for jet and airframe shielding effects. Results indicate that core noise can provide a barrier to the proposed EPA stage 4 and 5 federal noise rules for wide-body aircraft, with the most severe core noise problem occurring at takeoff and sideline measuring stations.

Von Glahn, U. H.↗

Strong electron heat flux modes in Jupiter's foreshock

Analysis of Voyager plasma wave data from the Jovian foreshock has revealed the existence of a new oscillation with center frequency below fp and typically lying above the upper limit Doppler shift frequency for ion acoustic waves. The properties of these waves are consistent with modes generated by a strong electron heat flux in an unmagnetized plasma. Such modes become unstable when the effective drift velocity exceeds n(cold)/(hot) exp 1/2 times the thermal speed of the hot component. The occasional simultaneous appearance of more than one frequency band is a possible indication of multiple magnetic connection with the shock.

Moses, S. L.↗

From Mars to Greenland: Charting gravity with space and airborne instruments - Fields, tides, methods, results

This symposium on space and airborne techniques for measuring gravity fields, and related theory, contains papers on gravity modeling of Mars and Venus at NASA/GSFC, an integrated laser Doppler method for measuring planetary gravity fields, observed temporal variations in the earth's gravity field from 16-year Starlette orbit analysis, high-resolution gravity models combining terrestrial and satellite data, the effect of water vapor corrections for satellite altimeter measurements of the geoid, and laboratory demonstrations of superconducting gravity and inertial sensors for space and airborne gravity measurements. Other papers are on airborne gravity measurements over the Kelvin Seamount; the accuracy of GPS-derived acceleration from moving platform tests; airborne gravimetry, altimetry, and GPS navigation errors; controlling common mode stabilization errors in airborne gravity gradiometry, GPS/INS gravity measurements in space and on a balloon, and Walsh-Fourier series expansion of the earth's gravitational potential.

Colombo, Oscar L.↗

The upper convective boundary layer

Progress made in understanding of the physics of the upper boundary layer of the sun, its influence on frequencies of five-minute oscillations, and its role in the excitation of the oscillations, are reviewed. The approaches taken for the seismological diagnosis of the properties of the layer are discussed. Information concerning the properties of the layer are obtained from Michelson Doppler imagery high-resolution data. The structure of the convective boundary layer is discussed considering high-resolution observations, three dimensional numerical simulations, the mean stratification of the convective layers, and the effects of momentum transfer by convection. The effects of convection on the oscillation frequencies, mode excitation, and mode damping, are discussed.

Kosovichev, Alexander G.↗

Coronal Structures in Cool Stars

Many papers have been published that further elucidate the structure of coronas in cool stars as determined from EUVE, HST, FUSE, Chandra, and XMM-Newton observations. In addition we are exploring the effects of coronas on the He I 1083081 transition that is observed in the infrared. Highlights of these are summarized below including publications during this reporting period and presentations. Ground-based magnetic Doppler imaging of cool stars suggests that active stars have active regions located at high latitudes on their surface. We have performed similar imaging in X-ray to locate the sites of enhanced activity using Chandra spectra. Chandra HETG observations of the bright eclipsing contact binary 44i Boo and Chandra LETG observations for the eclipsing binary VW Cep show X-ray line profiles that are Doppler-shifted by orbital motion. After careful analysis of the spectrum of each binary, a composite line-profile is constructed by adding the individual spectral lines. This high signal-to-noise ratio composite line-profile yields orbital velocities for these binaries that are accurate to 30 km/sec and allows their orbital motion to be studied at higher time resolutions. In conjunction with X-ray lightcurves, the phase-binned composite line-profiles constrain coronal structures to be small and located at high latitudes. These observations and techniques show the power of the Doppler Imaging Technique applied to X-ray line emission.

Oliversen, Ronald↗

Smallsat Navigation via the Deep Space Network: Inner Solar Systems Missions

The space industry has seen an explosion in the number of operational SmallSats in Earth orbit, with a natural interest in extending SmallSat capabilities outside of low Earth orbit. As with larger missions, near-term deep-space SmallSats will rely on the Deep Space Network or similar facilities. Given the predicted growth in the number of deep space missions, effective use of DSN resources will be more critical than ever. Our investigation provides an initial survey of expected inner Solar System navigation performance for DSN radiometric data types, from two-way Doppler and ranging to one-way equivalents, including delta differential one-way range and alternative tracking strategies.

Wood, Lincoln J.↗

Velocity measurements and free-shear-layer instabilities in a rotating liquid metal

The dynamics of rotating flows in magnetohydrodynamics (MHD) are expected to play an important role in astrophysical accretion disks, specifically via the generation of the magnetorotational instability (MRI). The Princeton MRI experiment, a Taylor-Couette device with split axial endcap rings and with a gallium-indium-tin working fluid, was constructed to study rotating MHD flows in the laboratory. This work uses an ultrasound Doppler velocimetry (UDV) diagnostic to measure internal fluid velocities of the mean background flow and also of fluctuations driven by instabilities in this experiment. Mean azimuthal velocities have been measured to show the effect of an applied axial magnetic field. For moderate magnetic field strengths, with the Elsasser number less than 1, the azimuthal velocity at a point, normalized to the inner cylinder velocity, is constant for a given Alfven speed normalized to the inner cylinder velocity. In the Elsasser much greater than 1 regime, the shear at the split in the endcaps extends axially as a free Shercliff layer through the full height of the experiment. When the inner endcap ring rotates faster than the outer endcap ring, the free shear layer produces a Kelvin-Helmholtz instability with an eigenmode that fills the experimental volume when Elsasser is greater than 1, or when there is sufficient background rotation so that the Rossby number is greater than 2.35. When the inner endcap ring rotates slower than the outer endcap ring, the Kelvin-Helmholtz instability is present in the absence of an applied magnetic field or background rotation. Using a linear eigenmode analysis of a free shear layer, the threshold for the appearance of the Kelvin-Helmholtz instability is presented as a competition between Rayleigh's centrifugal instability, which is driven by a negative radial gradient in the specific angular momentum, and the Kelvin-Helmholtz instability, which is driven by the velocity shear. Both instabilities act to smooth out the shear layer. While the eigenmodes of the centrifugal instability are confined to the free shear layer, allowing quiet flow in the bulk of the fluid when that instability dominates, the eigenmodes of the Kelvin-Helmholtz instability fill the fluid volume, creating large-amplitude coherent velocity fluctuations throughout.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of perturbations and a meal on superior mesenteric artery flow in patients with orthostatic hypotension

Our aims were to evaluate to role of superior mesenteric blood flow in the pathophysiology of orthostatic hypotension in patients with generalized autonomic failure. METHODS: Twelve patients with symptomatic neurogenic orthostatic hypotension and 12 healthy controls underwent superior mesenteric artery flow measurements using Doppler ultrasonography during head-up tilt and tilt plus meal ingestion. Autonomic failure was assessed using standard tests of the function of the sympathetic adrenergic, cardiovagal and postganglionic sympathetic sudomotor function. RESULTS: Superior mesenteric flow volume and time-averaged velocity were similar in patients and controls at supine rest; however, responses to cold pressor test and upright tilt were attenuated (p < 0.05) in patients compared to controls. Head-up tilt after the meal evoked a profound fall of blood pressure and mesenteric blood flow in the patients; the reduction of mesenteric blood flow correlated (r = 0.89) with the fall of blood pressure in these patients, providing another manifestation of failed baroreflexes. We make the novel finding that the severity of postprandial orthostatic hypotension regressed negatively with the postprandial increase in mesenteric flow in patients with orthostatic hypotension. CONCLUSION: Mesenteric flow is under baroreflex control, which when defective, results in, or worsens orthostatic hypotension. Its large size and baroreflexivity renders it quantitatively important in the maintenance of postural normotension. The effects of orthostatic stress can be significantly attenuated by reducing the splanchnic-mesenteric volume increase in response to food. Evaluation of mesenteric flow in response to eating and head-up tilt provide important information on intra-abdominal sympathetic adrenergic function, and the ability of the patient to cope with orthostatic stress.

Non-NASA Center↗

High-resolution CH stretch spectroscopy of jet-cooled cyclopentyl radical: First insights into equilibrium structure, out-of-plane puckering, and IVR dynamics

First, high-resolution sub-Doppler infrared spectroscopic results for cyclopentyl radical (C 5 H 9 ) are reported on the α-CH stretch fundamental with suppression of spectral congestion achieved by adiabatic cooling to T rot ≈ 19(4) K in a slit jet expansion. Surprisingly, cyclopentyl radical exhibits a rotationally assignable infrared spectrum, despite 3N – 6 = 36 vibrational modes and an upper vibrational state density (ρ ≈ 40–90 #/cm –1 ) in the critical regime (ρ ≈ 100 #/cm –1 ) necessary for onset of intramolecular vibrational relaxation (IVR) dynamics. Such high-resolution data for cyclopentyl radical permit detailed fits to a rigid-rotor asymmetric top Hamiltonian, initial structural information for ground and vibrationally excited states, and opportunities for detailed comparison with theoretical predictions. Specifically, high level ab initio calculations at the coupled-cluster singles, doubles, and perturbative triples (CCSD(T))/ANO0, 1 level are used to calculate an out-of-plane bending potential, which reveals a C 2 symmetry double minimum 1D energy surface over a C 2v transition state. Here, the inversion barrier [V barrier ≈ 3.7(1) kcal/mol] is much larger than the effective moment of inertia for out-of-plane bending, resulting in localization of the cyclopentyl wavefunction near its C 2 symmetry equilibrium geometry and tunneling splittings for the ground state too small (<1 MHz) to be resolved under sub-Doppler slit jet conditions. The persistence of fully resolved high-resolution infrared spectroscopy for such large cyclic polyatomic radicals at high vibrational state densities suggests a “deceleration” of IVR for a cycloalkane ring topology, much as low frequency torsion/methyl rotation degrees of freedom have demonstrated a corresponding “acceleration” of IVR processes in linear hydrocarbons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Marine Corps Base Camp Lejeune New River Estuary - Acoustic Doppler Current Profiler (ADCP) Results

Critical military training and testing on lands along the nation’s coastal and estuarine shorelines are increasingly placed at risk because of development pressures in surrounding areas, impairments due to other anthropogenic disturbances, and increasing requirements for compliance with environmental regulations. The U.S. Department of Defense (DoD) intends to enhance and sustain its training and testing assets and to optimize its stewardship of natural resources through the development and application of an ecosystem-based management approach on DoD installations. To accomplish this goal, particularly for installations in estuarine/coastal environments, the Strategic Environmental Research and Development Program (SERDP) launched the Defense Coastal/Estuarine Research Program (DCERP) as a minimum 10-year effort at Marine Corps Base Camp Lejeune (MCBCL) in North Carolina. The results of the first six years of the program (DCERP1) are presented here.The overarching objectives of DCERP are to: (1) understand the effects of military training activities, infrastructure development, and other coastal military installations; (2) develop models, tools, and indicators to evaluate ecosystem health; and (3) recommend adaptive management strategies to sustain ecosystem natural resources within the context of an active military installation.This data package contains a zipfile of results from Acoustic Doppler Current Profilers (ADCPs) used to collect current profiles throughout the New River Estuary in 2009: Teledyne RD Instrument’s acoustic Doppler current profilers (ADCPs) were deployed throughout the NRE to understand current flows and tidal extent. (Current velocity and water level data collected by the ADCPs were also used to validate a hydrodynamic model of the NRE.) Two ADCPS were deployed by Marker 12 and the Highway 172 bridge from late-February to early-July 2009. These ADCPs were attached to steel frames that rested on the sediment surface with the ADCP looking upward to make full water column profiles of water velocity minus a 1-m blanking between the instrument and sediment surface. Also attached to the steel frames were conductivity-temperature-depth (CTD) sensors, which provided concomitant salinity, temperature, and water depth data with the ADCP current measurements. Two ADCPS were also deployed in close proximity to the AVPs in Stones and Morgan Bays from mid-July to mid-December 2009. These ADCPs were deployed flush to the estuary floor to maximize the full vertical sampling capability at these shallow stations and the AVPs collected coincidental temperature, salinity, and depth measurements. For all deployments, the ADCPs were programmed in fast ping-rate mode 12 using 20 pings per ensemble and collected profiles in 10-cm bins every 6 minutes yielding a standard deviation in velocity measurements of 1.27 cm s-1. Current velocity and water level data were analyzed to understand the tidal influence on circulation within the NRE. Harmonic analyses were performed to extract the dominant tidal constituents from the velocity and depth records using T-tide run in MATLAB (Pawlowicz et al., 2002). These measurements of tidal amplitude and phase were then used to validate the high-resolution Advanced Circulation (ADCIRC) Model of the NRE region.

54 ENVIRONMENTAL SCIENCES↗

Phase noise in pulsed Doppler lidar and limitations on achievable single-shot velocity accuracy

The smaller sampling volumes afforded by Doppler lidars compared to radars allows for spatial resolutions at and below some sheer and turbulence wind structure scale sizes. This has brought new emphasis on achieving the optimum product of wind velocity and range resolutions. Several recent studies have considered the effects of amplitude noise, reduction algorithms, and possible hardware related signal artifacts on obtainable velocity accuracy. We discuss here the limitation on this accuracy resulting from the incoherent nature and finite temporal extent of backscatter from aerosols. For a lidar return from a hard (or slab) target, the phase of the intermediate frequency (IF) signal is random and the total return energy fluctuates from shot to shot due to speckle; however, the offset from the transmitted frequency is determinable with an accuracy subject only to instrumental effects and the signal to noise ratio (SNR), the noise being determined by the LO power in the shot noise limited regime. This is not the case for a return from a media extending over a range on the order of or greater than the spatial extent of the transmitted pulse, such as from atmospheric aerosols. In this case, the phase of the IF signal will exhibit a temporal random walk like behavior. It will be uncorrelated over times greater than the pulse duration as the transmitted pulse samples non-overlapping volumes of scattering centers. Frequency analysis of the IF signal in a window similar to the transmitted pulse envelope will therefore show shot-to-shot frequency deviations on the order of the inverse pulse duration reflecting the random phase rate variations. Like speckle, these deviations arise from the incoherent nature of the scattering process and diminish if the IF signal is averaged over times greater than a single range resolution cell (here the pulse duration). Apart from limiting the high SNR performance of a Doppler lidar, this shot-to-shot variance in velocity estimates has a practical impact on lidar design parameters. In high SNR operation, for example, a lidar's efficiency in obtaining mean wind measurements is determined by its repetition rate and not pulse energy or average power. In addition, this variance puts a practical limit on the shot-to-shot hard target performance required of a lidar.

Mcnicholl, P.↗

Note: Frequency-conversion photonic Doppler velocimetry with an inverted circulator

Photonic Doppler velocimetry (PDV) is a fiber-based interferometer used in dynamic compression research. Conventional PDV systems are simple to construct but do not perform well in all measurement conditions, while universal PDV systems that support many different configurations are complex and expensive. A simpler approach is the use of external, inverted circulators which can be added and removed in a modular fashion. This technique permits frequency-conversion measurements with a conventional PDV system. Using a correction to remove baseline effects, frequency conversion systems can resolve low velocity transients that conventional PDV cannot.