On Harmonizing Today’s Regulated Tariffs and Future Dynamic Electricity Pricing

A novel method for harmonizing the advantages of dynamic retail electricity pricing with the protections of regulated electricity tariffs is discussed and demonstrated. The method socializes and protects customers from long-term locational price variability that is unfair to those customers who are, by no fault of their own, served at congested locations on a distribution system. However, the method preserves short-term (e.g., diurnal) price variability that might induce helpful, mitigative responses from retail electricity customers. Because the method causes actual price recovery to track a customer class’s approved, regulated price recovery, the method may remove regulators’ objections to dynamic electricity pricing and thereby hasten adoption of market-based retail electricity pricing and transactive energy systems.

Consumer protection, Demand response, Market resea↗

Anodizing of High Electrically Stressed Components

Anodizing creates an aluminum oxide coating that penetrates into the surface as well as builds above the surface of aluminum creating a very hard ceramic-type coating with good dielectric properties. Over time and use, the electrical carrying components (or spools in this case) experience electrical breakdown, yielding undesirable x-ray dosages or failure. The spool is located in the high vacuum region of a rod pinch diode section of an x-ray producing machine. Machine operators have recorded decreases in x-ray dosages over numerous shots using the reusable spool component, and re-anodizing the interior surface of the spool does not provide the expected improvement. A machine operation subject matter expert coated the anodized surface with diffusion pump oil to eliminate electrical breakdown as a temporary fix. It is known that an anodized surface is very porous, and it is because of this porosity that the surface may trap air that becomes a catalyst for electrical breakdown. In this paper we present a solution of mitigating electrical breakdown by oiling. We will also present results of surface anodizing improvements achieved by surface finish preparation and surface sealing. We conclude that oiling the anodized surface and using anodized hot dip sealing processes will have similar results.

Anodizing, sealing, dielectric strength, surface q↗

Extracting Baseline Electricity Usage Using Gradient Tree Boosting

To understand how specific interventions affect a process observed over time, we need to control for the other factors that influence outcomes. Such a model that captures all factors other than the one of interest is generally known as a baseline. In our study of how different pricing schemes affect residential electricity consumption, the baseline would need to capture the impact of outdoor temperature along with many other factors. In this work, we examine a number of different data mining techniques and demonstrate Gradient Tree Boosting (GTB) to be an effective method to build the baseline. We train GTB on data prior to the introduction of new pricing schemes, and apply the known temperature following the introduction of new pricing schemes to predict electricity usage with the expected temperature correction. Our experiments and analyses show that the baseline models generated by GTB capture the core characteristics over the two years with the new pricing schemes. In contrast to the majority of regression based techniques which fail to capture the lag between the peak of daily temperature and the peak of electricity usage, the GTB generated baselines are able to correctly capture the delay between the temperature peak and the electricity peak. Furthermore, subtracting this temperature-adjusted baseline from the observed electricity usage, we find that the resulting values are more amenable to interpretation, which demonstrates that the temperature-adjusted baseline is indeed effective.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Joint Management and Optimization of Residential Natural Gas and Electricity Distribution Networks Coupled via Fuel Cells

The interesting properties of natural gas as well as the growing electric power demand worldwide have led to increasing attention to natural-gas-based distributed generation applications in electric distribution systems. This paper goes over the interdependency between a residential natural gas network and an electric distribution network that are coupled via fuel cells. The modeling of the gas network is introduced first, and then the algorithm for gas flow study is presented. The optimal placement and sizing of fuel cell based distributed generation systems are formulated to minimize the losses in both the gas and electric distribution networks, subject to their model constraints. In addition to this, in order to capture the probabilistic nature of the optimization problem under study, the K-means clustering algorithm is applied to the gas and electricity demands to determine hourly load states and their corresponding probabilities. Furthermore, simulation studies are carried out on an integrated system consisting of the IEEE 69-bus distribution feeder and a radial 27-node natural gas network to verify the developed optimization model and the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coordinated Scheduling for Interdependent Electric Power and Natural Gas Infrastructures

The extensive installation of gas-fired power plants in many parts of the world has led electric systems to depend heavily on reliable gas supplies. The use of gas-fired generators for peak load and reserve provision causes high intraday variability in withdrawals from high-pressure gas transmission systems. Such variability can lead to gas price fluctuations and supply disruptions that affect electric generator dispatch, electricity prices, and threaten the security of power systems and gas pipelines. These infrastructures function on vastly different spatio-temporal scales, which prevents current practices for separate operations and market clearing from being coordinated. Here in this article, we apply new techniques for control of dynamic gas flows on pipeline networks to examine day-ahead scheduling of electric generator dispatch and gas compressor operation for different levels of integration, spanning from separate forecasting, and simulation to combined optimal control. We formulate multiple coordination scenarios and develop tractable physically accurate computational implementations. These scenarios are compared using an integrated model of test networks for power and gas systems with 24 nodes and 24 pipes, respectively, which are coupled through gas-fired generators. The analysis quantifies the economic efficiency and security benefits of gas-electric coordination and dynamic gas system operation.

03 NATURAL GAS↗

Time-Lapse Electrical Geophysical Monitoring of Amendment-Based Biostimulation

Biostimulation is increasingly used to accelerate microbial remediation of recalcitrant groundwater contaminants. Effective application of biostimulation requires successful emplacement of amendment in the contaminant target zone. Verification of remediation performance requires postemplacement assessment and contaminant monitoring. Sampling based approaches are expensive and provide low-density spatial and temporal information. Time-lapse electrical resistivity tomography (ERT) is an effective geophysical method for determining temporal changes in subsurface electrical conductivity. Because remedial amendments and biostimulation-related biogeochemical processes often change subsurface electrical conductivity, ERT can complement and enhance sampling-based approaches for assessing emplacement and monitoring biostimulation-based remediation. Field studies demonstrating the ability of time-lapse ERT to monitor amendment emplacement and behavior were performed during a biostimulation remediation effort conducted at the Department of Defense Reutilization and Marketing Office (DRMO) Yard, in Brandywine, Maryland, United States. Geochemical fluid sampling was used to calibrate a petrophysical relation in order to predict groundwater indicators of amendment distribution. The petrophysical relations were field validated by comparing predictions to sequestered fluid sample results, thus demonstrating the potential of electrical geophysics for quantitative assessment of amendment-related geochemical properties. Crosshole radar zero-offset profile and borehole geophysical logging were also performed to augment the data set and validate interpretation. In addition to delineating amendment transport in the first 10 months after emplacement, the time-lapse ERT results show later changes in bulk electrical properties interpreted as mineral precipitation. Results support the use of more cost-effective surfacebased ERT in conjunction with limited field sampling to improve spatial and temporal monitoring of amendment emplacement and remediation performance.

amendment↗

Thermal Energy Storage and its Potential Applications in Solar Thermal Power Plants and Electricity Storage

With the rapid growth of renewable power generation, economically storing large quantities of solar- and wind-generated electricity may become as important as renewable power itself. The combination of renewable power generation and energy storage can overcome the variability of renewable power generation alone and create the opportunity for renewable generation to provide base-load electricity.For peak power usage, the integration of renewable power and storage of excess electricity has several significant and positive impacts: expanding the renewable energy portion of total electricity generation, improving the peak-load response, and coordinating the electricity supply and demand over the grid. Several energy storage approaches exist, with mechanical, chemical, and electricalmethods either in use now or being developed. Comparing their efficiencies as well as their economic uses for different scales and applications helps determine the right technology for the right purpose. This paper will study the possibility of using thermal energy storage as a means for electricity storage, and compare it to other energy storage methods including batteries, flywheels, compressed air, and pumped hydropower.

14 SOLAR ENERGY↗

Review of recent studies on nanoscale electrical junctions and contacts: Quantum tunneling, current crowding, and interface engineering

The study of charge carrier transport at nanoscale electrical contacts is crucial for the development of next-generation electronics. In this study, we review recent modeling efforts on quantum tunneling, current crowding, and contact resistance across electrical interfaces with nanometer scale dimensions. A generalized self-consistent model for quantum tunneling induced electron transport in metal–insulator–metal (MIM) junctions is summarized. Rectification of a dissimilar MIM junction is reviewed. A modified two-dimensional (2D) transmission line model is used to investigate the effects of spatially varying specific contact resistivity along the contact length. The model is applied to various types of electrical contacts, including ohmic contacts, MIM junction based tunneling contacts, and 2D-material-based Schottky contacts. Roughness engineering is recently proposed to offer a possible paradigm for reducing the contact resistance of 2D-material-based electrical contacts. Contact interface engineering, which can mitigate current crowding near electrical contacts by spatially designing the interface layer thickness or properties, without requiring an additional material or component, is briefly reviewed. Tunneling engineering is suggested to eliminate severe current crowding in highly conductive ohmic contacts by introducing a thin tunneling layer or gap between the contact members. Furthermore, unsolved problems and challenges are also discussed.

2D materials↗

Electric field control of magnon spin currents in an antiferromagnetic insulator

Pure spin currents can be generated via thermal excitations of magnons. These magnon spin currents serve as carriers of information in insulating materials, and controlling them using electrical means may enable energy efficient information processing. Here, we demonstrate electric field control of magnon spin currents in the antiferromagnetic insulator Cr 2 O 3 . We show that the thermally driven magnon spin currents reveal a spin-flop transition in thin-film Cr 2 O 3 . Crucially, this spin-flop can be turned on or off by applying an electric field across the thickness of the film. Using this tunability, we demonstrate electric field–induced switching of the polarization of magnon spin currents by varying only a gate voltage while at a fixed magnetic field. We propose a model considering an electric field–dependent spin-flop transition, arising from a change in sublattice magnetizations via a magnetoelectric coupling. These results provide a different approach toward controlling magnon spin current in antiferromagnets.

36 MATERIALS SCIENCE↗

Electrically Conductive and Protective Coating for Planar SOFC Stacks

Ferritic stainless steels are preferred interconnect materials for intermediate temperature SOFCs because of their resistance to oxidation, high formability and low cost. However, their protective oxide layer produces Cr-containing volatile species at SOFC operating temperatures and conditions, which can cause cathode poisoning. Electrically conducting spinel coatings have been developed to prevent cathode poisoning and to maintain an electrically conductive pathway through SOFC stacks. However, this coating is not compatible with the formation of stable, hermetic seals between the interconnect frame component and the ceramic cell. Thus, a new aluminizing process has been developed by PNNL to enable durable sealing, prevent Cr evaporation, and maintain electrical insulation between stack repeat units. Hence, two different types of coating need to have stable operation of SOFC stacks. This paper will focus on the electrically conductive coating process. Moreover, an advanced coating process, compatible with a non-electrically conductive coating will be

Choi, Jung-Pyung↗

BEEAM (Building Electrical Efficiency Analysis Model) [SWR-20-107]

Modern high-performance buildings exhibit an increasing number of building loads that use direct current (DC) electricity internally, rather than alternating current (AC), due to the advent of low-cost computing and advanced power electronics. Powering DC devices from the AC grid requires AC/DC power conversion, which introduces energy losses and reduces efficiency. As DC loads proliferate, the cumulative wasted energy associated with hundreds of millions of AC/DC converters has become one of the broadest energy savings opportunities in buildings. DC power distribution systems have been proposed as an elegant and transformative solution to the problem of DC devices. In a DC distribution system, the building's wires carry DC electricity, rather than AC; and a few centralized, highly efficient AC/DC converters replace the many smaller, less efficient converters that serve individual DC loads. Unfortunately, the trade-offs associated with DC distribution systems are not well understood. Reported energy savings associated with DC power distribution differ widely and have not been well validated. The Building Electrical Efficiency Analysis Model (BEEAM) is a Modelica library that simulates the efficiency of building electrical distribution systems using harmonic power flow. BEEAM can model a wide variety of building distribution topologies, including three-phase AC, single-phase AC, unipolar DC, bipolar DC, and hybrid networks under both balanced and unbalanced load conditions. BEEAM accurately models power electronic converter losses, provides granular estimates of losses throughout the distribution system, and properly models efficiency at part load conditions. Users can package BEEAM within a functional mockup unit (FMU), enabling co-simulation with other modeling platform, such as EnergyPlus. In summary, BEEAM provides a tool suite for fair and accurate comparison of the efficiency of building electrical distribution systems, including AC, DC, and hybrid systems.

Frank, Stephen↗

The direct-current response of electrically conducting fractures excited by a grounded current source

Hydraulic fracture stimulation of low permeability reservoir rocks is an established and cross–cutting technology for enhancing hydrocarbon production in sedimentary formations and increasing heat exchange in crystalline geothermal systems. Whereas the primary measure of success is the ability to keep the newly generated fractures sufficiently open, long–term reservoir management requires a knowledge of the spatial extent, morphology, and distribution of the fractures — knowledge primarily informed by microseismic and ground deformation monitoring. To minimize the uncertainty associated with interpreting such data, we investigate through numerical simulation the usefulness of direct-current (DC) resistivity data for characterizing subsurface fractures with elevated electrical conductivity by considering a geophysical experiment consisting of a grounded current source deployed in a steel cased borehole. In doing so, the casing efficiently energizes the fractures with steady current. Finite element simulations of this experiment for a horizontal well intersecting a small set of vertical fractures indicate that the fractures manifest electrically in (at least) two ways: (1) a local perturbation in electric potential proximal to the fracture set, with limited farfield expression and (2) an overall reduction in the electric potential along the borehole casing due to enhanced current flow through the fractures into the surrounding formation. The change in casing potential results in a measurable effect that can be observed far from fractures themselves. Under these conditions, our results suggest that farfield, timelapse measurements of DC potentials can be interpreted by simple, linear inversion for a Coulomb charge distribution along the borehole path, including a local charge perturbation due to the fractures. As a result, this approach offers an inexpensive method for detecting and monitoring the time-evolution of electrically conducting fractures while ultimately providing an estimate of their effective conductivity — the latter providing an important measure independent of seismic methods on fracture shape, size, and hydraulic connectivity.

30 DIRECT ENERGY CONVERSION↗

A parametric analysis of oilfield design factors affecting the detectability and characterization of electrically conductive hydrofracks

Electrical responses in the vicinity of energized steel-cased well sources offer significant potential for monitoring induced fractures. However, the high complexity of well-fracture-host models spanning multiple length scales compels analysts to simplify their numerical models due to enormous computational costs. This consequently limits our understanding regarding monitoring capabilities and the limitations of electrical measurements on realistic hydraulically fracturing systems. In this paper, we use the hierarchical finite element approach to construct geoelectric models in which geometrically complex fractures and steel-cased wells are discretely represented in 3D conducting media without sacrificing the model realism and computation efficiency. We have discovered systematic numerical analyses of the electrical responses to evaluate the influences of borehole material conductivity and the source type as well as the effects of well geometry, conductivity contrast, source location, fracture growth, and fracture propagation. Furthermore, the numerical results indicate that the borehole material property has a strong control on the electrical potentials along the production and monitoring wells. The monopole source located at a steel-cased well results in a current density distribution that decays away from the source location throughout the well length, whereas the dipole source produces a current density that dominates mainly along the dipole length. Moreover, the conductivity contrast between the fractures and host does not change the overall pattern of the electrical potentials but varies its amplitude. The fracture models near different well systems indicate that the well geometry controls the entire distribution of potentials, while the characteristics of the voltage difference profiles along the wells before and after fracturing are insensitive to the well geometry and the well in which the source is located. Further, the hydraulic-fracturing models indicate that the voltage differences along the production well before and after fracturing have strong sensitivity to fracture growth and fracture set propagation.

58 GEOSCIENCES↗

Coherent homodyne detection for amplified cross-beam electric-field induced second harmonic

The electric-field induced second harmonic (E-FISH) signal sensing is commonly used as a nonlinear optical technique to probe electric fields inside a plasma region. Cross-beam E-FISH is being investigated to improve spatial resolution by defining the interaction volume via a controlled geometry of two overlapping noncolinear optical beams. This drastic reduction in interaction length of the electric field and laser region results in a significant signal reduction. Here, to overcome this signal reduction, we introduce coherent amplification of the cross-beam E-FISH signal by mixing the low E-FISH signal with a phase-locked bright local oscillator. We demonstrate enhancement of the signal. By introducing a local oscillator we can now derive the polarity of the measured electric field through the phase of the homodyne signal. To illustrate the technique, we, for the first time, to the best of our knowledge, measure the magnitude and the direction of the electric field in a cold atmospheric pressure plasma jet, which dynamically follows the profile of the applied bias current.

42 ENGINEERING↗

Electrically tunable nonlinear light generation in plasmonic tunnel junctions

Active and efficient control of nonlinear optical processes is essential for integrated photonics, with applications in signal processing, ultrafast switching, and quantum light manipulation. While nanophotonic structures are powerful for enhancing nonlinearities, achieving wide-range electrical tunability has remained a challenge. Plasmonic tunnel junctions offer a unique path to bridge this gap because they combine extreme optical field confinement with direct electrical control in a single nanoscale device. Here, we report the first, to our knowledge, demonstration of electrically tunable second-harmonic generation (SHG) in plasmonic tunnel junctions. Using ultra-stable epitaxial heterostructures, we achieve reproducible modulation of SHG with depths up to ∼500% and magnitudes above 1.3V −1 . We identify two mechanisms, electric-field-induced SHG (EFISH) and ion migration, that can either compete or cooperate depending on junction thickness and bias, enabling both broad tunability and ferroelectric-like hysteretic switching. These findings establish plasmonic tunnel junctions as a platform for electrically controlled nonlinear optics, with potential for nanoscale light sources, reconfigurable modulators, and neuromorphic photonic devices..

42 ENGINEERING↗

MODELING OF ENHANCED AIR DEHUMIDIFICATION THROUGH ELECTRICALLY CHARGED VAPOR CAPTURING ELECTROSTATIC DROPLETS

This paper investigated the potential of a new electrostatic-based water vapor separation system for humidity control in buildings. The Electrospray Vortical Flow eXchanger (EVFX) consists of small electrically charged water droplets released inside air vortexes to attract water vapor molecules, effectively wiping out the humidity from the air. Larger droplets are then removed at the outer wall of the vortex. If a water molecule is placed in a gradient electric field, such a polar molecule experiences a dielectrophoresis force, which moves the molecules and produces a vapor concentration gradient. When the vapor density exceeds the saturation level, nucleation occurs. A thermodynamic model that captures this phenomenon was described in this paper. Electrosprayed droplets were initially charged close to their maximum electrical charge dictated by the Rayleigh limit; these droplets were used as nucleation centers. The high electric charge decreased the pressure of the vapor, which was in equilibrium with the droplets. This enhanced the charged droplets' nucleation and growth that depleted the vapor phase near the droplets, which was compensated for by the dielectrophoresis flow and diffusion. Significant water vapor condensation was predicted for small droplets at a high electrical charge. Beyond a specific droplet size, while the condensation of water vapor was still theoretically possible, it was somewhat limited because the further growth of the large charged droplets was inhibited due to their high inherent water vapor pressure near the surface. A case study illustrated the potentials and limitation of the EVFX for droplets charged to the Rayleigh limit, for which the effective range of diameters resulted between 10 nm up to few micron.

Morcelli, Stefano↗

Application of Spatial Data Modeling and Geographical Information Systems (GIS) for Identification of Potential Siting Options for Various Electrical Generation Sources

Oak Ridge National Laboratory (ORNL) initiated an internal National Electric Generation Siting Study, which is an ongoing multiphase study addressing several key questions related to our national electrical energy supply. This effort has led to the development of a tool, OR-SAGE (Oak Ridge Siting Analysis for power Generation Expansion), to support siting evaluations. The objective in developing OR-SAGE was to use industry-accepted approaches and/or develop appropriate criteria for screening sites and employ an array of Geographic Information Systems (GIS) data sources at ORNL to identify candidate areas for a power generation technology application. The initial phase of the study examined nuclear power generation. These early nuclear phase results were shared with staff from the Electric Power Research Institute (EPRI), which formed the genesis and support for an expansion of the work to several other power generation forms, including advanced coal with carbon capture and storage (CCS), solar, and compressed air energy storage (CAES). Wind generation was not included in this scope of work for EPRI. The OR-SAGE tool is essentially a dynamic visualization database. The results shown in this report represent a single static set of results using a specific set of input parameters. In this case, the GIS input parameters were optimized to support an economic study conducted by EPRI. A single set of individual results should not be construed as an ultimate energy solution, since US energy policy is very complex. However, the strength of the OR-SAGE tool is that numerous alternative scenarios can be quickly generated to provide additional insight into electrical generation or other GIS-based applications. The screening process divides the contiguous United States into 100 x 100 m (1-hectare) squares (cells), applying successive power generation-appropriate site selection and evaluation criteria (SSEC) to each cell. There are just under 700 million cells representing the contiguous United States. If a cell meets the requirements of each criterion, the cell is deemed a candidate area for siting a specific power generation form relative to a reference plant for that power type. Some SSEC parameters preclude siting a power plant because of an environmental, regulatory, or land-use constraint. Other SSEC assist in identifying less favorable areas, such as proximity to hazardous operations. All of the selected SSEC tend to recommend against sites. The focus of the ORNL electrical generation source siting study is on identifying candidate areas from which potential sites might be selected, stopping short of performing any detailed site evaluations or comparisons. This approach is designed to quickly screen for and characterize candidate areas. Critical assumptions supporting this work include the supply of cooling water to thermoelectric power generation; a methodology to provide an adequate siting footprint for typical power plant applications; a methodology to estimate thermoelectric plant capacity while accounting for available cooling water; and a methodology to account for future ({approx}2035) siting limitations as population increases and demands on freshwater sources change. OR-SAGE algorithms were built to account for these critical assumptions. Stream flow is the primary thermoelectric plant cooling source evaluated in this study. All cooling was assumed to be provided by a closed-cycle cooling (CCC) system requiring makeup water to account for evaporation and blowdown. Limited evaluations of shoreline cooling and the use of municipal processed water (gray) cooling were performed. Using a representative set of SSEC as input to the OR-SAGE tool and employing the accompanying critical assumptions, independent results for the various power generation sources studied were calculated.

01 COAL, LIGNITE, AND PEAT↗

Recovery Act: Johnston Rhode Island Combined Cycle Electric Generating Plant Fueled by Waste Landfill Gas

The primary objective of the Project was to maximize the productive use of the substantial quantities of waste landfill gas generated and collected at the Central Landfill in Johnston, Rhode Island. An extensive analysis was conducted and it was determined that utilization of the waste gas for power generation in a combustion turbine combined cycle facility was the highest and best use. The resulting project reflected a cost effective balance of the following specific sub-objectives. 1) Meet environmental and regulatory requirements, particularly the compliance obligations imposed on the landfill to collect, process and destroy landfill gas. 2) Utilize proven and reliable technology and equipment. 3) Maximize electrical efficiency. 4) Maximize electric generating capacity, consistent with the anticipated quantities of landfill gas generated and collected at the Central Landfill. 5) Maximize equipment uptime. 6) Minimize water consumption. 7) Minimize post-combustion emissions. To achieve the Project Objective the project consisted of several components. 1) The landfill gas collection system was modified and upgraded. 2) A State-of-the Art gas clean up and compression facility was constructed. 3) A high pressure pipeline was constructed to convey cleaned landfill gas from the clean-up and compression facility to the power plant. 4) A combined cycle electric generating facility was constructed consisting of combustion turbine generator sets, heat recovery steam generators and a steam turbine. 5) The voltage of the electricity produced was increased at a newly constructed transformer/substation and the electricity was delivered to the local transmission system. The Project produced a myriad of beneficial impacts. 1) The Project created 453 FTE construction and manufacturing jobs and 25 FTE permanent jobs associated with the operation and maintenance of the plant and equipment. 2) By combining state-of-the-art gas clean up systems with post combustion emissions control systems, the Project established new national standards for best available control technology (BACT). 3) The Project will annually produce 365,292 MWh's of clean energy. 4) By destroying the methane in the landfill gas, the Project will generate CO{sub 2} equivalent reductions of 164,938 tons annually. The completed facility produces 28.3 MWnet and operates 24 hours a day, seven days a week.

09 BIOMASS FUELS↗