Search NASA⌕ Search

SEARCH · Search NASA

Results for “fitting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Application of a Multiscale Model of Tantalum Deformation at Megabar Pressures

A new multiscale simulation tool has been developed to model the strength of tantalum under high-pressure dynamic compression. This new model combines simulations at multiple length scales to explain macroscopic properties of materials. Previously known continuum models of material response under load have built upon a mixture of theoretical physics and experimental phenomenology. Experimental data, typically measured at static pressures, are used as a means of calibration to construct models that parameterize the material properties; e.g., yield stress, work hardening, strain-rate dependence, etc. The pressure dependence for most models enters through the shear modulus, which is used to scale the flow stress. When these models are applied to data taken far outside the calibrated regions of phase space (e.g., strain rate or pressure) they often diverge in their predicted behavior of material deformation. The new multiscale model, developed at Lawrence Livermore National Laboratory, starts with interatomic quantum mechanical potential and is based on the motion and multiplication of dislocations. The basis for the macroscale model is plastic deformation by phonon drag and thermally activated dislocation motion and strain hardening resulting from elastic interactions among dislocations. The dislocation density, {rho}, and dislocation velocity, {nu}, are connected to the plastic strain rate {var_epsilon}{sup p}, via Orowan's equation: {var_epsilon}{sup p} = {rho}b{nu}/M, where b is the Burger's vector, the shear magnitude associated with a dislocation, and M is the Taylor factor, which accounts for geometric effects in how slip systems accommodate the deformation. The evolution of the dislocation density and velocity is carried out in the continuum model by parameterized fits to smaller scale simulations, each informed by calculations on smaller length scales down to atomistic dimensions. We apply this new model for tantalum to two sets of experiments and compare the results with more traditional models. The experiments are based on the Barnes's technique in which a low density material loads against a metal surface containing a pre-imposed rippled pattern. The loaded sample is Rayleigh-Taylor unstable and the rippled amplitudes grow with time. The rate of growth differs depending on the material strength, with stronger materials growing less, even to the point of saturation. One set of experiments was conducted at the pRad facility at LANSCE at Los Alamos National Laboratory in 2007 using high-explosive (HE) driven tantalum samples. The other set of experiments was done at the Omega laser at the Laboratory for Laser Energetics at the University of Rochester, which used high-powered lasers to create plasmas to dynamically compress a rippled tantalum sample. The two techniques provide data at different pressures and strain rates: The HE technique drives the samples at around 2 x 10{sup 5} s{sup -1} strain rate and pressures near 500 kbar, while the laser technique hits strain rates around 2 x 10{sup 7} s{sup -1} and pressures close to 1.4 Mbar. The most recent laser experiments were conducted in February 2010 and they present a sample of the data in Figure 1, which shows a face-on radiograph at a time of 65 ns after the laser was turned on. From this radiograph, they measure the growth factor which is defined to be the change in amplitude of the ripples relative to their initial amplitude. Figure 2 shows the resulting growth factors along with various model fits. The error bars are typically 20-25%. Only the multiscale model predictions match the experimental measurements. The growth factors via the HE technique are determined from multiple side-on proton radiography images and thus provide a full growth curve per single experiment. A sample growth curve is shown in Figure 3, also with various model fits and error bars estimated at 25%. It should be noted that by 7.5 {micro}s the growth in this sample has exceeded the initial target thickness indicating that localizations not captured in the overall simulation have probably become dominant, i.e., the target is likely breaking up. Application of the multiscale dislocation dynamics model as implemented in the Ares hydrodynamics code shows excellent agreement with both the pRad and Omega data. They also compare the Steinberg-Lund (SL), Preston-Tonks-Wallace (PTW), and Stainberg-Guinan (SG) models with the data. The PTW and SG models provide good fits to the pRad data but over-predict the growth (underestimate the strength) on the laser platform. The SL model under-predicts the pRad data and over-predicts the Omega data. The excellent agreement of the multiscale model with the data over two orders of magnitude in strain rate and more than a factor of two in pressure lends credibility to the model. They continue to stress the model by conducting experiments at 5 Mbars and beyond at the National Ignition Facility at LLNL in the near future.

36 MATERIALS SCIENCE↗

Expressing precision and bias in calorimetry

The calibration and calibration verification of a nuclear calorimeter represents a substantial investment of time in part because a single calorimeter measurement takes of the order of 2 to 24h to complete. The time to complete a measurement generally increases with the size of the calorimeter measurement well. It is therefore important to plan the sequence of measurements rather carefully so as to cover the dynamic range and achieve the required accuracy within a reasonable time frame. This work will discuss how calibrations and their verification has been done in the past and what we consider to be good general practice in this regard. A proposed approach to calibration and calibration verification is presented which, in the final analysis, makes use of all the available data - both calibration and verification collectively - in order to obtain the best (in a best fit sense) possible calibration. The combination of sample variance and percent recovery are traditionally taken as sufficient to capture the random (precision) and systematic (bias) contributions to the uncertainty in a calorimetric assay. These terms have been defined as well as formulated for a basic calibration. It has been tradition to assume that sensitivity is a linear function of power. However, the availability of computer power and statistical packages should be utilized to fit the response function as accurately as possible using whatever functions are deemed most suitable. Allowing for more flexibility in the response function fit will enable the calibration to be updated according to the results from regular validation measurements through the year. In a companion paper to be published elsewhere we plan to discuss alternative fitting functions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A survey of techniques to estimate the uncertainty in material parameters.

When estimating parameters for a material model from experimental data collected during a separate effects physics experiment, the quality of fit is only a part of the required data. Also necessary is the uncertainty in the estimated parameters so that uncertainty quantification and model validatino can be performed at the full system level. The uncertainty and quality of fit of the data are many times not available and should be considered when fitting the data to a specified model. There are many techniques available to fit data to a material model and a few of them are presented in this work using a simple acoustical emission dataset. The estimated parameters and the affiliated uncertainty will be estimated using a variety of techniques and compared.

36 MATERIALS SCIENCE↗

Effect of numerical parameters on characterizing the hardening behavior of ductile uniaxial tension specimens.

Many problems of practical importance involve ductile materials that undergo very large strains, in many cases to the point of failure. Examples include structures subjected to impact or blast loads, energy absorbing devices subjected to significant crushing, cold-forming manufacturing processes and others. One of the most fundamental pieces of data that is required in the analysis of this kind of problems is the fit of the uniaxial stress-strain curve of the material. A series of experiments where mild steel plates were punctured with a conical indenter provided a motivation to characterize the true stress-strain curve until the point of failure of this material, which displayed significant ductility. The hardening curve was obtained using a finite element model of the tensile specimens that included a geometric imperfection in the form of a small reduction in the specimen width to initiate necking. An automated procedure iteratively adjusted the true stress-strain curve fit used as input until the predicted engineering stress-strain curve matched experimental measurements. Whereas the fitting is relatively trivial prior to reaching the ultimate engineering stress, the fit of the softening part of the engineering stress-stain curve is highly dependent on the finite element parameters such as element formulation and initial geometry. Results by two hexahedral elements are compared. The first is a standard, under-integrated, uniform-strain element with hourglass control. The second is a modified selectively-reduced-integration element. In addition, the effects of element size, aspect ratio and hourglass control characteristics are investigated. The effect of adaptively refining the mesh based on the aspect ratio of the deformed elements is also considered. The results of the study indicate that for the plate puncture problem, characterizing the material with the same element formulation and size as used in the plate models is beneficial. On the other hand, using different element formulations, sizes or initial aspect ratios can lead to unreliable results.

36 MATERIALS SCIENCE↗

Milky Way Tomography IV: Dissecting Dust

We use SDSS photometry of 73 million stars to simultaneously obtain best-fit main-sequence stellar energy distribution (SED) and amount of dust extinction along the line of sight towards each star. Using a subsample of 23 million stars with 2MASS photometry, whose addition enables more robust results, we show that SDSS photometry alone is sufficient to break degeneracies between intrinsic stellar color and dust amount when the shape of extinction curve is fixed. When using both SDSS and 2MASS photometry, the ratio of the total to selective absorption, R{sub V}, can be determined with an uncertainty of about 0.1 for most stars in high-extinction regions. These fits enable detailed studies of the dust properties and its spatial distribution, and of the stellar spatial distribution at low Galactic latitudes (|b| < 30{sup o}). Our results are in good agreement with the extinction normalization given by the Schlegel et al. (1998, SFD) dust maps at high northern Galactic latitudes, but indicate that the SFD extinction map appears to be consistently overestimated by about 20% in the southern sky, in agreement with recent study by Schlafly et al. (2010). The constraints on the shape of the dust extinction curve across the SDSS and 2MASS bandpasses disfavor the reddening law of O'Donnell (1994), but support the models by Fitzpatrick (1999) and Cardelli et al. (1989). For the latter, we find a ratio of the total to selective absorption to be R{sub V} = 3.0 {+-} 0.1(random) {+-} 0.1 (systematic) over most of the high-latitude sky. At low Galactic latitudes (|b| < 5{sup o}), we demonstrate that the SFD map cannot be reliably used to correct for extinction because most stars are embedded in dust, rather than behind it, as is the case at high Galactic latitudes. We analyze three-dimensional maps of the best-fit R{sub V} and find that R{sub V} = 3.1 cannot be ruled out in any of the ten SEGUE stripes at a precision level of {approx} 0.1 - 0.2. Our best estimate for the intrinsic scatter of R{sub V} in the regions probed by SEGUE stripes is {approx} 0.2. We introduce a method for efficient selection of candidate red giant stars in the disk, dubbed 'dusty parallax relation', which utilizes a correlation between distance and the extinction along the line of sight. We make these best-fit parameters, as well as all the input SDSS and 2MASS data, publicly available in a user-friendly format. These data can be used for studies of stellar number density distribution, the distribution of dust properties, for selecting sources whose SED differs from SEDs for high-latitude main sequence stars, and for estimating distances to dust clouds and, in turn, to molecular gas clouds.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Gamma ray spectroscopy employing divalent europium-doped alkaline earth halides and digital readout for accurate histogramming

A scintillator radiation detector system according to one embodiment includes a scintillator; and a processing device for processing pulse traces corresponding to light pulses from the scintillator, wherein pulse digitization is used to improve energy resolution of the system. A scintillator radiation detector system according to another embodiment includes a processing device for fitting digitized scintillation waveforms to an algorithm based on identifying rise and decay times and performing a direct integration of fit parameters. A method according to yet another embodiment includes processing pulse traces corresponding to light pulses from a scintillator, wherein pulse digitization is used to improve energy resolution of the system. A method in a further embodiment includes fitting digitized scintillation waveforms to an algorithm based on identifying rise and decay times; and performing a direct integration of fit parameters. Additional systems and methods are also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Battery Life Data Analysis

The FreedomCar Partnership has established life goals for batteries. Among them is a 15 year calendar life. The software and the underlying methodology attempt to predict cell and battery life using, at most, two years of test data. The software uses statistical models based on data from accelerated aging experiments to estimate cell life. The life model reflects the average cell performance under a given set of stress conditions with time. No specific form of the life model is assumed. The software will fit the model to experimental data. An error model, reflecting the cell-to-cell variability and measurement errors, is included in the software. Monte Carlo simulations, based on the developed models, are used to assess Lack-of-fit and develop uncertainty limis for the average cell life. The software has three operating modes: fit only, fit and simulation and simulation only. The user is given these options by means of means and alert boxes.

Source record↗

Grid Frequency Extreme Event Analysis and Modeling: Preprint

Sudden losses of generation or load can lead to instantaneous changes in electric grid frequency and voltage. Extreme frequency events pose a major threat to grid stability. As renewable energy sources supply power to grids in increasing proportions, it becomes increasingly important to examine when and why extreme events occur to prevent destabilization of the grid. To better understand frequency events, including extrema, historic data were analyzed to fit probability distribution functions to various frequency metrics. Results showed that a standard Cauchy distribution fit the difference between the frequency nadir and prefault frequency (f_(C-A)) metric well, a standard Cauchy distribution fit the settling frequency (f_B) metric well, and a standard normal distribution fit the difference between the settling frequency and frequency nadir (f_(B-C)) metric very well. Results were inconclusive for the frequency nadir (f_C) metric, meaning it likely has a more complex distribution than those tested. This probabilistic modeling should facilitate more realistic modeling of grid faults.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fourier domain dynamic correction method for complex optical fringes in laser spectrometers

A method is provided for Fourier domain dynamic correction of optical fringes in a laser spectrometer. The method includes Fourier transforming a background spectrum contaminated with the optical fringes to obtain baseline fringes in a frequency domain. The method includes partitioning the baseline fringes in the frequency domain to obtain partitioned baseline fringes. The method includes reconstructing the partitioned baseline fringes as separate spectra. The method includes constructing a fitting model to approximate the background spectrum by assigning a first and a second free parameter to each of partitioned baseline fringe components to respectively allow for drift and amplitude adjustments during a fitting of the fitting model. The method includes applying the fitting model to a newly acquired spectrum to provide an interpretation of the newly acquired spectrum having a reduced influence of spectral contamination on concentration retrieval.

Teng, Cheyenne↗

Machine-Learning Assisted Identification of Battery Life Models

Predictive battery life models are commonly utilized to extrapolate degradation trends observed during accelerated aging tests for simulation of degradation in real-world applications. Thus, fitting accelerated aging data as accurately as possible and with low uncertainty is crucial for making believable projections of battery lifetime, but it is challenging to identify algebraic expressions that accurately fit multivariate degradation trends. A review of models published in literature reveal some common expressions for fitting calendar aging data, which is only dependent on temperature and state-of-charge, but no consistency across many models for fitting cycle aging data, indicating the need for a statistically rigorous data driven approach for developing empirical models. This talk will describe a machine-learning assisted method for identification of predictive battery life models utilizing bilevel optimization and symbolic regression. Bilevel optimization with cross-validation is used to statistically determine cell- and stress-dependent model parameters, while symbolic regression identifies both linear and multiplicative candidate expressions to predict stress-dependent degradation rates by selecting low-order subsets of features from a generated feature library. Because model expressions are identified empirically, it is crucial to ensure resulting models behave according to physical expectations, so the stability of models for interpolation or extrapolation is interrogated qualitatively through simulation and quantitatively through cross-validation and uncertainty quantification via bootstrap resampling. This model identification approach substantially improves upon models identified purely using expert judgement in terms of both accuracy and uncertainty. Model simulation and validation is then conducted by deriving a state-equation form of the predictive model, enabling simulation of battery aging under dynamic stresses. This enables validation of the predictive battery model on lab-based tests with varying conditions or on drive-cycle or application-cycle testing protocols. Parameter uncertainty can be carried forward into model simulation, giving lifetime estimates and confidence windows for cell- or system-level lifetime. The financial impact of battery model uncertainty can be estimated by incorporating uncertainty into a technoeconomic model.

battery↗

XAFS Investigation of Uranium Binding by Seawater-Contacted Amidoxime Adsorbents

Extraction of uranium from seawater constitutes an important avenue for ensuring nuclear fuel availability beyond the coming century. With a predicted 100 years of uranium remaining in terrestrial ores, efficient extraction of the 4.5 billion tons of uranium dissolved in ocean water would enable access to an effectively limitless supply. More near-term benefits include establishment of a backstop technology, preventing runaway price inflation for this critical resource. The current state-of-the-art material for seawater extraction of uranium is a polymeric adsorbent composed of a robust trunk material subsequently surface functionalized by copolymerization of polyacrylonitrile and a hydrophilic comonomer. Treatment of this material with hydroxylamine results in the formation of poly-amidoxime functionalities which have been known to bind strongly with uranium since the early 1980's. Despite more than three decades of investigation, many questions remain unanswered regarding how these adsorbents bind uranium in seawater. The physical characteristics of the polymer prohibit many classical characterization techniques, while most spectroscopic approaches are impeded by the relatively low concentration of uranium compared to the polymer itself and other metals extracted by the adsorbent. The traditional approach has been to investigate small molecule analogues of uranyl - dioxouranium (VI), the form of uranium present in seawater - as bound by amidoxime or amidoxime derivatives, and assert the findings to be representative of the larger polymer system. Computational efforts have also been recently leveraged to a similar end. This approach is not without difficulty, as it has been routinely proposed that the treatment with hydroxylamine and subsequent alkaline conditioning results in formation of a cyclic imide dioxime site, which is truly responsible for uranium binding, as opposed to the 'open chain' amidoxime. Further complications ensue from considering the possibility of cooperative binding interactions from the different hydrophilic comonomers which are known to be necessary for optimizing uranium capacity. Finally, application of different surface polymerization techniques has the potential to directly affect the morphology of the surface polymer by influencing the degree of grafting, extent of polymer crosslinking, and polymer density. The impact of these morphological considerations on the uranyl binding environment cannot be easily replicated with small molecule studies or by computation. Ultimately, the precise binding environment of uranium is unknown, but constitutes critical knowledge for the design and engineering of advanced adsorbent materials capable of selective extraction of uranium from seawater. Analysis of the EXAFS fits reveals three of the four polymer morphologies appear to bind uranium in different chemical environments, none of which were predicted by crystallographic study or computational investigation, challenging numerous long-held assumptions. Both AI-8 and AN/HEA spectra possess features which could be attributable to cooperative binding of uranium by comonomers, but this cannot be definitively determined by EXAFS without further investigation. Unlike AF-1, neither AI-8 or AN/HEA require an adjacent μ{sup 2}-oxo-bridged transition metal to obtain a reasonable fit. The fit for Cyclic AF-1 is refined to almost identical parameters to the fit of the original AF-1 adsorbent, with the only difference is the contracting of the light elements in the second coordination sphere. It is thus proposed that the DMSO and heat treatment of the AF-1 fiber does very little to change the uranium binding site, and any differences in uptake are more readily explained by changes in the morphology of the graft polymer. There is no evidence for cyclic amidoxime functionality contributing significantly to the extraction of uranium from seawater, and efforts to maximize the number of these binding sites should be discontinued. While molecular interactions necessarily occur in adsorption processes, these results clearly reveal physical phenomena at the mesoscale play a critical role in adsorbent behavior, even to the extent that the binding environment differs from those predicted by small molecule studies. In contrast to the current paradigm where chemical functionality is varied, improvements in the performance of polymer-based amidoxime-functionalized adsorbents for extraction of uranium from seawater need also be pursued through interrogation and modulation of bulk morphology and improvements in polymer hydrophilicity. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Study of Plastic Scintillator Properties for Radioactive Sources Dosimetry - Paper 108

Plastic scintillator is a simple material which has the density close to that of human soft tissue (1.06 g/cm{sup 3}). Its energy response is close to that of human soft tissue and it is relatively energy independent. This prospect provide a desired characteristics in measuring dose by plastic scintillator either for radiation monitoring or personal dosimeter. Generally the energy calibration of organic scintillator will be done by using gamma ray sources. The positions of Compton edge in pulse height spectra, which have known energy values will be identified. However the Compton edge normally is very broad and difficult to determine the point corresponding to that particular Compton electron energies. Many researchers used several fitting functions and Monte Carlo simulations to determine the position of Compton edge. For example, Proctor and Wellman (2012) used a straight line fit to the linear part of Compton edge and extrapolated to zero count. While L. Swiderski et al. used a method based on a back-scattered coincidence measurement to measure in a wide energy range the position of Compton edge in organic scintillators. For a simple and quick approach of calibration, we used a Gauss-error function to fit the Compton edge region of interest by assumed that the location of maximum energy of Compton electrons is half-height of the Compton maximum (CM). The reasons is because the CM position could be determined easily from the spectra throughout wide energy range. Interpreting gamma dose rates from accumulated plastic scintillation detector spectra is often a complex task because the probability of a full energy deposition event in the detector is often negligible. Despite no full energy peaks in plastic scintillator spectra, several attempts have been made by the other researchers to obtain the dose from the energy distribution spectra of gamma radiation. For example, Proctor and Wellman used the modified spectrum dose index (SDI) to calculate the exposure rates by multiplying the energy corresponding to its channel and all products are summed before multiply by a calibration constant to yield an exposure rate. While Lobdell and Hertel calculated dose using a response matrix based on spectral unfolding technique. From these points of view, we have made an attempt to correlate the counts obtained in scintillator with absorbed dose or ambient dose equivalent. We aimed to calibrate the plastic scintillator energy deposition for dose, by correlate the counts obtained with a particular value of dose. By designed the scintillator to measure at 1 cm tissue depth might be helpful to be used as radiation monitoring or personal dosimeter since the energy response of plastic scintillator is relatively energy independent compared to that of inorganic scintillators. The energy calibration proposed from simple fitting approach had been verified with calculated spectra. This might be considered as a practical approach for technician or radiation workers with sufficient accuracy. The linear behavior of counts per absorbed dose give promising to calibrate scintillator energy deposition to read dose (equivalent dose or absorbed dose) for photons. Thus the scintillator could provide both the energy and dose response simultaneously, which may important in some radiation field of measurements. Currently the scintillator is able to give dose rate value for gamma sources of Cs-137 and Mn-54. The number of counts per unit absorbed dose would likely to vary somewhat with photon energy, although the plastic scintillator should have a tissue dose response that is relatively energy independent. Further analysis will be done on conversion factor parameters so that it could be used in such situations where the radiation field is complex or unknown. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The DESI DR1 Peculiar Velocity Survey: Growth Rate Measurements from the Galaxy Power Spectrum

The large-scale structure of the Universe and its evolution encapsulate a wealth of cosmological information. A powerful means of unlocking this knowledge lies in measuring the auto-power spectrum and/or the cross-power spectrum of the galaxy density and momentum fields, followed by the estimation of cosmological parameters based on these spectrum measurements. In this study, we generalize the cross-power spectrum model to accommodate scenarios where the density and momentum fields are derived from distinct galaxy surveys. The growth rate of the large-scale structures of the Universe, commonly represented as $fσ_8$, is extracted by jointly fitting the monopole and quadrupole moments of the auto-density power spectrum, the monopole of the auto-momentum power spectrum, and the dipole of the cross-power spectrum. Our estimators, theoretical models and parameter-fitting framework have been tested using mocks, confirming their robustness and accuracy in retrieving the fiducial growth rate from simulation. These techniques are then applied to analyze the power spectrum of the DESI Bright Galaxy Survey and Peculiar Velocity Survey, and the fit result of the growth rate is $fσ_8=0.440^{+0.080}_{-0.096}$ at effective redshift $z_{\rm eff}=0.07$. By synthesizing the fitting outcomes from correlation functions, maximum likelihood estimation and power spectrum, yields a consensus value of $fσ_8(z_{\rm eff}=0.07) = 0.450 ^{+0.055}_{-0.055}$, and correspondingly we obtain $γ=0.580^{+0.110}_{-0.110}$, $Ω_\mathrm{m}=0.301^{+0.011}_{-0.011}$ and $σ_8=0.834^{+0.032}_{-0.032}$. The measured $fσ_8$ and $γ$ are consistent with the prediction of the $Λ$ Cold Dark Matter Model and General Relativity.

Qin, F. [Marseille, CPPM] (ORCID:0000000179507864)↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme

The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector. *************************************** AUTHOR = Slater, Bethany University of Liverpool b.slater2@liverpool.ac.uk TITLE = Enhancing Sterile Neutrino Oscillation Sensitivities using SBND-PRISM at the Short-Baseline Neutrino Programme PAGES = 218 NOTE = Ph.D. University of Liverpool March 2026 ABSTRACT = The Short-Baseline Neutrino (SBN) Programme at Fermilab is comprised of two detectors, SBND and ICARUS, placed at $110$\,m and $600$\,m along the Booster Neutrino Beam at Fermilab. The key physics aim of the programme is to definitively test the sterile neutrino hypothesis, a proposed fourth flavour of neutrino that may explain certain experimental anomalies seen regarding standard model neutrino oscillations. To be able to detect the existence of sterile neutrinos, the uncertainties of the programme must be well constrained. To enable this, a robust analysis must be constructed that can consistently identify the correct values of systematic parameters and generate accurate predictions of what the neutrino energy spectrum at ICARUS should look like. SBND's design allows for the introduction of a technique called PRISM. In PRISM, the detector is divided into regions of different off axis angles from the beam, forming different samples where systematics impact each one in a distinct way. This allows any fits performed to obtain a better understanding of the correct value of the systematic parameters. The first analysis included in this thesis focuses on the improvements seen to the sensitivity of SBN to sterile oscillation parameters when using a PRISM configuration instead of treating SBND as a single whole. Focusing on the $5\sigma$ exclusion contour from the $\numu$ disappearance channel using three PRISM samples, an improvement on the order of $30$\,\% is seen, extending the parameter space for which the null hypothesis can be excluded. This thesis also presents a series of mock data studies comparing the abilities of SBND and PRISM analyses, concluding that in the case of simple changes between Monte Carlo (MC) and data, PRISM produces predictions of the ICARUS event rate spectrum that are more accurate and have smaller uncertainties. When moving to more realistic mock data, using different models to create the mock data than were used for the MC, the postfit predictions at ICARUS had a smaller difference between the postfit and mock data reconstructed energy spectra across all mock data samples tested. Finally, a covariance matrix defined by the maximum discrepancy between the postfit and mock data spectra at ICARUS from each of the SBND and PRISM fits across all the samples was constructed. The resultant $1\sigma$ fractional error induced by this bias systematic on the postfit spectrum has a smaller magnitude for PRISM than SBND, with the improvements ranging from $2.21$\,\% to $6.26$\,\% depending on the mock data samples. This summarises the reduction in systematic error when using PRISM instead of treating SBND as a single detector.

Slater, Bethany [Liverpool U.]↗

Surface Complexation Model for Strontium Sorption to Amorphous Silica and Goethite

Strontium sorption to amorphous silica and goethite was measured as a function of pH and dissolved strontium and carbonate concentrations at 25 C. Strontium sorption gradually increases from 0 to 100% from pH 6 to 10 for both phases and requires multiple outer-sphere surface complexes to fit the data. All data are modeled using the triple layer model and the site-occupancy standard state; unless stated otherwise all strontium complexes are mononuclear. Strontium sorption to amorphous silica in the presence and absence of dissolved carbonate can be fit with tetradentate Sr{sup 2+} and SrOH{sup +} complexes on the {beta}-plane and a monodentate Sr{sup 2+} complex on the diffuse plane to account for strontium sorption at low ionic strength. Strontium sorption to goethite in the absence of dissolved carbonate can be fit with monodentate and tetradentate SrOH{sup +} complexes and a tetradentate binuclear Sr{sup 2+} species on the {beta}-plane. The binuclear complex is needed to account for enhanced sorption at high strontium surface loadings. In the presence of dissolved carbonate additional monodentate Sr{sup 2+} and SrOH{sup +} carbonate surface complexes on the {beta}-plane are needed to fit strontium sorption to goethite. Modeling strontium sorption as outer-sphere complexes is consistent with quantitative analysis of extended X-ray absorption fine structure (EXAFS) on selected sorption samples that show a single first shell of oxygen atoms around strontium indicating hydrated surface complexes at the amorphous silica and goethite surfaces. Strontium surface complexation equilibrium constants determined in this study combined with other alkaline earth surface complexation constants are used to recalibrate a predictive model based on Born solvation and crystal-chemistry theory. The model is accurate to about 0.7 log K units. More studies are needed to determine the dependence of alkaline earth sorption on ionic strength and dissolved carbonate and sulfate concentrations for the development of a robust surface complexation database to estimate alkaline earth sorption in the environment.

54 ENVIRONMENTAL SCIENCES↗

Giant dipole resonance parameters with uncertainties from photonuclear cross sections

Updated values and corresponding uncertainties of isovector giant dipole resonance (IVGDR or GDR) model parameters are presented that are obtained by the least-squares fitting of theoretical photoabsorption cross sections to experimental data. The theoretical photoabsorption cross section is taken as a sum of the components corresponding to excitation of the GDR and quasideuteron contribution to the experimental photoabsorption cross section. The present compilation covers experimental data as of January 2010. - Highlights: {yields} Experimental {sigma} ({gamma}, abs) or a sum of partial cross sections are taken as input to the fitting. {yields} Data include contributions from photoproton reactions. {yields} Standard (SLO) or modified (SMLO) Lorentzian approaches are used for formulating GDR models. {yields} Spherical or axially deformed nuclear shapes are used in GDR least-squares fit. {yields} Values and uncertainties of the SLO and SMLO GDR model parameters are tabulated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗