Search NASA⌕ Search

SEARCH · Search NASA

Results for “high availability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Applications of data mining technology to enhance O and M: automatic planning of electrical isolation with deep learning - 255

Data mining technology is now readily available, thanks to high powered, low cost computing resource and useful coding tools. We study several applications of data mining to enhance operation and maintenance (O and M), such as abnormality prediction, efficiency diagnosis, document traceability, image recognition, etc. In field support, we try automatic planning of electrical isolation with deep learning. Currently, a skilled engineer plans electrical isolation procedure with hundreds of the circuit diagrams and the related documents, taking man-hours. If this task becomes automatic, it is very efficient. The automatic planning has two issues. One is much calculation time of electrical circuit simulator, searching billions of electrical conducting paths. The other is interpretation of human fuzzy information, such as ease of work. Deep learning is helpful to resolve them. We performed a model case study of the electrical isolation. We applied a deep neural network (DNN) for dropping in the calculation time. We trained the circuit diagrams and the responses of the circuit simulator to the DNN, constructing an efficient path search algorithm in the DNN. The calculation time of the DNN was shorter by a factor of 32 for the model case, compared with that of the electrical circuit simulator. We applied a deep Q-network (DQN) for the interpretation of fuzzy information. The DQN optimized isolation procedure from the viewpoint of the work load with the equipment layout, related doses, and values of wet bulb globe temperature (WBGT) to prevent heatstroke. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Equipping Neural Network Surrogates with Uncertainty for Propagation in Physical Systems

Coarse-grained or filtered models typically rely on closure models to account for unresolved scales. For instance, large eddy simulation for modeling turbulent fluid flows explicitly resolves the largest scales, but requires modeling closure terms to account for the sub-filter scales. With the vast amount of data available from high-fidelity simulations, there are unique opportunities to leverage data-driven modeling techniques to formulate expressive and flexible closure models. Despite their flexibility, data-driven models struggle in domain shift settings, i.e. when deployed in configurations not captured in the training dataset. In particular, the efficacy of neural network surrogates is difficult to assess a priori due to the deterministic, point-estimate nature of predictions. In high-consequence applications, such models require reliable uncertainty estimates in the data-informed and out-of-distribution regimes. To quantify uncertainties in both regimes, we employ Bayesian neural networks which are able to capture both epistemic and aleatoric uncertainties. We will discuss challenges associated with the training and evaluation of these networks. Furthermore, we will discuss uncertainty embedding strategies to enable efficient sampling and propagation of uncertainty through high-fidelity simulations.

Bayesian neural networks↗

Recent QCD Results

The study of the inelastic scattering of hadrons has progressed in the last decade. With the availability of high-statistics data sets from HERA and the Tevatron, our understanding of high energy and high jet multiplicity events has become rather precise. In this Proceedings, I present an overview of recent jet-only results, as well as measurements of events which combine both jets and a W or Z boson.

Lincoln, Don↗

GaTe semiconductor for radiation detection

GaTe semiconductor is used as a room-temperature radiation detector. GaTe has useful properties for radiation detectors: ideal bandgap, favorable mobilities, low melting point (no evaporation), non-hygroscopic nature, and availability of high-purity starting materials. The detector can be used, e.g., for detection of illicit nuclear weapons and radiological dispersed devices at ports of entry, in cities, and off shore and for determination of medical isotopes present in a patient.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Way Beyond Widgets: Delivering Integrated Lighting Design in Actionable Solutions

Previously, energy-efficiency strategies for commercial spaces have focused on using efficient equipment without providing specific detailed instructions. Designs by experts in their fields are an energy-efficiency product in its own right. A new national program has developed interactive application-specific lighting designs for widespread use in four major commercial sectors. This paper will describe the technical basis for the solutions, energy efficiency and cost-savings methodology, and installations and measurement/verification to-date. Lighting designs have been developed for five types of retail stores (big box, small box, grocery, specialty market, and pharmacy) and are planned for the office, healthcare, and education sectors as well. Nationally known sustainable lighting designers developed the designs using high-performance commercially available products, daylighting, and lighting controls. Input and peer review was received by stakeholders, including manufacturers, architects, utilities, energy-efficiency program sponsors (EEPS), and end-users (i.e., retailers). An interactive web tool delivers the lighting solutions and analyzes anticipated energy savings using project-specific inputs. The lighting solutions were analyzed against a reference building using the space-by-space method as allowed in the Energy Standard for Buildings Except Low-Rise Residential Buildings (ASHRAE 2004) co-sponsored by the American Society of Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE) and the Illuminating Engineering Society of North America (IESNA). The results showed that the design vignettes ranged from a 9% to 28% reduction in the allowed lighting power density. Detailed control strategies are offered to further reduce the actual kilowatt-hour power consumption. When used together, the lighting design vignettes and control strategies show a modeled decrease in energy consumption (kWh) by 33% to 50% below the baseline design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Performance I/O: HDF5 for Lattice QCD

Practitioners of lattice QCD/QFT have been some of the primary pioneer users of the state-of-the-art high-performance-computing systems, and contribute towards the stress tests of such new machines as soon as they become available. As with all aspects of high-performance-computing, I/O is becoming an increasingly specialized component of these systems. In order to take advantage of the latest available high-performance I/O infrastructure, to ensure reliability and backwards compatibility of data files, and to help unify the data structures used in lattice codes, we have incorporated parallel HDF5 I/O into the SciDAC supported USQCD software stack. Here we present the design and implementation of this I/O framework. Our HDF5 implementation outperforms optimized QIO at the 10-20% level and leaves room for further improvement by utilizing appropriate dataset chunking.

Kurth, Thorsten↗

High-Performance I/O: HDF5 for Lattice QCD

Practitioners of lattice QCD/QFT have been some of the primary pioneer users of the state-of-the-art high-performance-computing systems, and contribute towards the stress tests of such new machines as soon as they become available. As with all aspects of high-performance-computing, I/O is becoming an increasingly specialized component of these systems. In order to take advantage of the latest available high-performance I/O infrastructure, to ensure reliability and backwards compatibility of data files, and to help unify the data structures used in lattice codes, we have incorporated parallel HDF5 I/O into the SciDAC supported USQCD software stack. Here we present the design and implementation of this I/O framework. Our HDF5 implementation outperforms optimized QIO at the 10-20% level and leaves room for further improvement by utilizing appropriate dataset chunking.

97 MATHEMATICS AND COMPUTING↗

High-pressure liquid chromatography of aromatic amines

Analysis made on commercially available liquid chromatograph demonstrates high-pressure liquid chromatographic conditions for separation of approximately 50 aromatic amines ranging from simple aniline derivatives to complex multiring di- and tri-amines.

Young, P. R.↗

Radiochemistry Research and Training, UC Davis

The report contains a summary of the accomplishments made during the R2@UCDavis proposal. In brief we proposed to develop new and highly innovative radiotracer methods and to enhance training opportunities to ensure the future availability of human resources for highly specialized fields of radiotracer development chemistry and clinical nuclear medicine research and allied disciplines. The overall scientific objectives of this proposal were to utilize “click” chemistry to facilitate fast and site-specific radiolabeling. Progress was made on all initial goals presented. This funding has to date resulted in publications in high impact journals such as Acta Biomaterialia, Molecular Imaging and Biology, Nuclear Medicine and Biology and most recently Environmental Science and technology, and it is anticipated that through the collaborations established during the time course of this funding that future research will be published in clinically relevant journals such as Science Translational Medicine and the Journal of Nuclear Medicine. Trainees involved in this proposal have gone on to further their careers in both academia, industry and the private sector. The collaborative forums established during the time course of this funding will ensure the future availability of human resources for highly specialized fields of radiotracer development chemistry and clinical nuclear medicine research and allied disciplines.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Chemical stability of high-temperature superconductors

A review of the available studies on the chemical stability of the high temperature superconductors (HTS) in various environments was made. The La(1.8)Ba(0.2)CuO4 HTS is unstable in the presence of H2O, CO2, and CO. The YBa2Cu3O(7-x) superconductor is highly susceptible to degradation in different environments, especially water. The La(2-x)Ba(x)CuO4 and Bi-Sr-Ca-Cu-O HTS are relatively less reactive than the YBa2Cu3O(7-x). Processing of YBa2Cu3O(7-x) HTS in purified oxygen, rather than in air, using high purity noncarbon containing starting materials is recommended. Exposure of this HTS to the ambient atmosphere should also be avoided at all stages during processing and storage. Devices and components made out of these oxide superconductors would have to be protected with an impermeable coating of a polymer, glass, or metal to avoid deterioration during use.

Bansal, Narottam P.↗

Nuclear Data Sheets for A = 75

The experimental nuclear spectroscopic data for known nuclides of mass number 75 (Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Se, Br, Kr, Rb, Sr) have been evaluated and presented together with Adopted properties for levels and γ rays. New high-spin data are available for {sup 75}Ga, and {sup 75}Rb; and lifetime data for high-spin states in {sup 75}Br and {sup 75}Kr. For ΔJ =1, M1+E2 transitions in two rotational bands in {sup 75}Kr, several B(E2)(W.u.) values are anomalously high, deviating by 2–3 σ values from currently accepted RUL(E2) = 300. In the opinion of the evaluators, there is need to remeasure level lifetimes and multipole mixing ratios in {sup 75}Kr to resolve this serious discrepancy. New precise single-particle transfer cross section data are available for {sup 75}Ga, {sup 75}Ge, {sup 75}As and {sup 75}Se from several different reactions (2009Ka06,2008Sc03); these data give information for occupancy of valence neutron orbitals in the ground states of target nuclides: {sup 76}Ge, {sup 76}Se and {sup 78}Se. No significant new data since the 1999 NDS for A = 75 have been reported for {sup 75}As and {sup 75}Se. No data are yet available for excited states in {sup 75}Co, {sup 75}Ni and {sup 75}Sr. For {sup 75}Fe, only the isotopic identification is made with one observed event. The radioactive decay schemes of {sup 75}Co and {sup 75}Ni are unknown while those for {sup 75}Rb and {sup 75}Sr are incomplete. This work supersedes the data presented in the previous NDS evaluation of A = 75 published by 1999Fa05.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dosimetric characterization and output verification for conical brachytherapy surface applicators. Part I. Electronic brachytherapy source

Purpose: Historically, treatment of malignant surface lesions has been achieved with linear accelerator based electron beams or superficial x-ray beams. Recent developments in the field of brachytherapy now allow for the treatment of surface lesions with specialized conical applicators placed directly on the lesion. Applicators are available for use with high dose rate (HDR){sup 192}Ir sources, as well as electronic brachytherapy sources. Part I of this paper will discuss the applicators used with electronic brachytherapy sources; Part II will discuss those used with HDR {sup 192}Ir sources. Although the use of these applicators has gained in popularity, the dosimetric characteristics including depth dose and surface dose distributions have not been independently verified. Additionally, there is no recognized method of output verification for quality assurance procedures with applicators like these. Existing dosimetry protocols available from the AAPM bookend the cross-over characteristics of a traditional brachytherapy source (as described by Task Group 43) being implemented as a low-energy superficial x-ray beam (as described by Task Group 61) as observed with the surface applicators of interest. Methods: This work aims to create a cohesive method of output verification that can be used to determine the dose at the treatment surface as part of a quality assurance/commissioning process for surface applicators used with HDR electronic brachytherapy sources (Part I) and{sup 192}Ir sources (Part II). Air-kerma rate measurements for the electronic brachytherapy sources were completed with an Attix Free-Air Chamber, as well as several models of small-volume ionization chambers to obtain an air-kerma rate at the treatment surface for each applicator. Correction factors were calculated using MCNP5 and EGSnrc Monte Carlo codes in order to determine an applicator-specific absorbed dose to water at the treatment surface from the measured air-kerma rate. Additionally, relative dose measurements of the surface dose distributions and characteristic depth dose curves were completed in-phantom. Results: Theoretical dose distributions and depth dose curves were generated for each applicator and agreed well with the measured values. A method of output verification was created that allows users to determine the applicator-specific dose to water at the treatment surface based on a measured air-kerma rate. Conclusions: The novel output verification methods described in this work will reduce uncertainties in dose delivery for treatments with these kinds of surface applicators, ultimately improving patient care.

61 RADIATION PROTECTION AND DOSIMETRY↗

Nuclear Data Sheets for A=85

Evaluated experimental data are presented for 13 known nuclides of mass 85 (Zn, Ga, Ge, As, Se, Br, Kr, Rb, Sr, Y, Zr, Nb, Mo). Since the previous 1990 evaluation of A=85, {sup 85}Zn, {sup 85}Ga, {sup 85}Ge and {sup 85}nuclides are newly added here. Excited state data for {sup 85}Se, {sup 85}Zr have become available from radioactive decay and in–beam γ–ray studies. New and improved high–spin data are available for {sup 85}Br, {sup 85}Kr, {sup 85}Rb, {sup 85}Y, {sup 85}Nb and {sup 85}Mo. New direct and precise measurement of atomic masses of {sup 85}Ge, {sup 85}As, {sup 85}Se, {sup 85}Br, {sup 85}Rb, {sup 85}Zr, {sup 85}Nb and {sup 85}Mo have greatly improved the landscape of β decay–Q values and separation energies in this mass region. In spite of extensive experimental work on the isobaric nuclei of this mass chain several deficiencies remain. No excited states are known in {sup 85}Zn, {sup 85}Ga, {sup 85}As. Only a few excited state are assigned in {sup 85}Ge from {sup 85}Ga β– decay. From radioactivity studies, the decay schemes of {sup 85}Zn and {sup 85}Mo are not known, and those for {sup 85}Ga, {sup 85}Ge, {sup 85}As and 10.9–s isomer of {sup 85}Zr are incomplete. Level lifetimes are not known for excited states in {sup 85}Se, {sup 85}Br, {sup 85}Nb and {sup 85}Mo. The {sup 85}Tc nuclide has not been detected in fragmentation experiments at GANIL, alluding to its unbound nature for proton emission. The {sup 85}Kr, {sup 85}Rb, {sup 85}Sr, and {sup 85}Y nuclides remain the most extensively studied from many different reactions and decays. The evaluation of A=85 nuclides has been done after a span of 23 years, thus includes an extensive amount of new data for almost each nuclide. This work supersedes the data for A=85 nuclides presented in earlier full NDS publication by J. Tepel in 1980Te04 and a later one published in an update mode by H. Sievers in 1991Si01.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DATASET RELEASE AND QUALITY CONTROL REVIEW OF LIVERMORE NEVADA NETWORK (LNN) RECORDINGS OF A SUBSET OF NEVADA NUCLEAR SECURITY SITE NUCLEAR EXPLOSIONS FROM 1979 TO 1992.

Geophysical research on historical nuclear tests is an important aspect of future monitoring capabilities in seismic research. This research is challenging due to the limited number of digital seismic recordings during the peak of nuclear testing (1945-1992). These limited records are unique and non-reproducible data with potential high research impact. Releasing available nuclear explosion seismic records to the explosion monitoring community is thus of high value and is the motivation for this dataset release. The target of this effort was on compilation and quality control of regional seismic records of nuclear explosions recorded on Lawrence Livermore National Laboratory stations ELK, KNB, LAC, and MNV, known collectively as the Livermore National Network (LNN) (Figure 1). LNN was established in the early 1960s for the primary purpose of monitoring underground nuclear testing at the former Nevada Test Site (NTS), now known as the Nevada Nuclear Security Site (NNSS) following the signing of the Limited Test Ban Treaty (LTBT). LNN consisted initially of short-period vertical component Benioff’s recorded on film located at Mina, NV (MNV) and Kanab, Utah (KNB). LNN added two additional stations at Landers, CA (LAC) and Elko, NV (ELK) in 1967 and upgraded equipment to broadband seismometers recorded on frequency modulation (FM) tapes from 1967-1979, followed by digital recordings after 1979 (Jarpe, 1989). The digital recordings were on a variety of now obsolete media, including 9-track, Exabyte, and DAT tapes. Jarpe (1989) describes the seismic station instrumentation details over the period of deployment. LNN recorded valuable non-repeatable unique data of several hundreds of nuclear explosions at NNSS, as well as earthquakes and chemical and mining explosions (Walter, 2020). The details of these nuclear tests are provided in the Department of Energy Report NV-209 Rev 16 (DOE, 2015).

58 GEOSCIENCES↗