Search NASA⌕ Search

SEARCH · Search NASA

Results for “image simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

WE-EF-207-05: Monte Carlo Dosimetry for a Dedicated Cone-Beam CT Head Scanner

Purpose: Cone-Beam CT (CBCT) is an attractive platform for point-of-care imaging of traumatic brain injury and intracranial hemorrhage. This work implements and evaluates a fast Monte-Carlo (MC) dose estimation engine for development of a dedicated head CBCT scanner, optimization of acquisition protocols, geometry, bowtie filter designs, and patient-specific dosimetry. Methods: Dose scoring with a GPU-based MC CBCT simulator was validated on an imaging bench using a modified 16 cm CTDI phantom with 7 ion chamber shafts along the central ray for 80–100 kVp (+2 mm Al, +0.2 mm Cu). Dose distributions were computed in a segmented CBCT reconstruction of an anthropomorphic head phantom with 4×10{sup 5} tracked photons per scan (5 min runtime). Circular orbits with angular span ranging from short scan (180° + fan angle) to full rotation (360°) were considered for fixed total mAs per scan. Two aluminum filters were investigated: aggressive bowtie, and moderate bowtie (matched to 16 cm and 32 cm water cylinder, respectively). Results: MC dose estimates showed strong agreement with measurements (RMSE<0.001 mGy/mAs). A moderate (aggressive) bowtie reduced the dose, per total mAs, by 20% (30%) at the center of the head, by 40% (50%) at the eye lens, and by 70% (80%) at the posterior skin entrance. For the no bowtie configuration, a short scan reduced the eye lens dose by 62% (from 0.08 mGy/mAs to 0.03 mGy/mAs) compared to full scan, although the dose to spinal bone marrow increased by 40%. For both bowties, the short scan resulted in a similar 40% increase in bone marrow dose, but the reduction in the eye lens was more pronounced: 70% (90%) for the moderate (aggressive) bowtie. Conclusions: Dose maps obtained with validated MC simulation demonstrated dose reduction in sensitive structures (eye lens and bone marrow) through combination of short-scan trajectories and bowtie filters. Xiaohui Wang and David Foos are employees of Carestream Health.

60 APPLIED LIFE SCIENCES↗

QUBIC II: Spectral polarimetry with bolometric interferometry

Bolometric interferometry is a novel technique that has the ability to perform spectral imaging. A bolometric interferometer observes the sky in a wide frequency band and can reconstruct sky maps in several sub-bands within the physical band in post-processing of the data. This provides a powerful spectral method to discriminate between the cosmic microwave background (CMB) and astrophysical foregrounds. In this paper, the methodology is illustrated with examples based on the Q & U Bolometric Interferometer for Cosmology (QUBIC) which is a ground-based instrument designed to measure the B-mode polarization of the sky at millimeter wavelengths. We consider the specific cases of point source reconstruction and Galactic dust mapping and we characterize the point spread function as a function of frequency. We study the noise properties of spectral imaging, especially the correlations between sub-bands, using end-to-end simulations together with a fast noise simulator. Finally, we conclude showing that spectral imaging performance are nearly optimal up to five sub-bands in the case of QUBIC.

79 ASTRONOMY AND ASTROPHYSICS↗

MO-DE-BRA-05: EUTEMPE-RX: Combining E-Learning and Face-To-Face Training to Build Expert Knowledge, Skills and Competences for Medical Physicists in Diagnostic and Interventional Radiology

Purpose: In 2013, the EURATOM authorities of the European Commission decided to support the Horizon2020 project submission ‘EUTEMPE-RX’ that aimed for a new set of course modules to train medical physicists in diagnostic and interventional radiology to expert level with small group deep learning. Each module would consist of 2 phases: an e-learning and a face-to-face phase, each phase requiring typically 40h of participant time. Methods: The European Federation (EFOMP) and 13 European partners, all of them selected for their excellent scientific and/or educational skills, led the 12 course modules. A quality manual ensured the quality of course content and organization. Educational workshops familiarized the teachers with e-learning techniques and methods for assessment. Content was set in accordance with the EC document RP174 that lists learning outcomes in terms of knowledge, skills and competences (KSCs) for different specialties and levels of medical physics. Surveys for stake holder satisfaction were prepared. Results: Today the course modules are being realized. The modules cover most of the KSCs in RP174 document. Teachers have challenged the participants with unique tasks: case studies in medical physics leadership, Monte Carlo simulation of a complete x-ray imaging chain, development of a task specific QA protocol, compilation of optimization plans, simulation tasks with anthropomorphic breast models, etc. Participants undertook practical sessions in modern hospitals and visited a synchrotron facility, a calibration lab, screening organizations, etc. Feedback form quality surveys was very positive and constructive. A sustainability plan has been worked out. Conclusion: The modules have enabled the participants to develop their KSCs and cope with challenges in medical physics. The sustainability plan will be implemented to continue the unique combined e-learning and face to face training at high level training in diagnostic and interventional radiology also beyond Europe. The EUTEMPE-RX project is funded by the Horizon2020 - EURATOM program of the European Commission.

60 APPLIED LIFE SCIENCES↗

Surface determination through atomically resolved secondary-electron imaging

We report that unique determination of the atomic structure of technologically relevant surfaces is often limited by both a need for homogeneous crystals and ambiguity of registration between the surface and bulk. Atomically resolved secondary-electron imaging is extremely sensitive to this registration and is compatible with faceted nanomaterials, but has not been previously utilized for surface structure determination. Here we show a detailed experimental atomic-resolution secondary-electron microscopy analysis of the c(6 x 2) reconstruction on strontium titanate (001) coupled with careful simulation of secondary-electron images, density functional theory calculations and surface monolayer-sensitive aberration-corrected plan-view high-resolution transmission electron microscopy. Our work reveals several unexpected findings, including an amended registry of the surface on the bulk and strontium atoms with unusual seven-fold coordination within a typically high surface coverage of square pyramidal TiO 5 units. Lastly, dielectric screening is found to play a critical role in attenuating secondary-electron generation processes from valence orbitals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Image resolution: Its significance in a wildland area

The information content of simulated space photos as a function of various levels of image resolution was determined by identifying major vegetation-terrain types in a series of images purposely degraded optically to different levels of ground resolution resolvable distance. Comparison of cumulative interpretation results with actual ground truth data indicates that although there is definite decrease in interpretability as ground resolvable distance increases, some valuable information is gained by using even the poorest aerial photography. Developed is the importance of shape and texture for correct identification of broadleaf or coniferous vegetation types and the relative unimportance of shape and texture for the recognition of grassland, water bodies, and nonvegetated areas. Imagery must have a ground resolvable distance of at least 50 feet to correctly discriminate between primary types of woody vegetation.

Lauer, D. T.↗

Black-box optimization of CT acquisition and reconstruction parameters: a reinforcement learning approach

Protocol optimization is critical in Computed Tomography (CT) for achieving desired diagnostic image quality while minimizing radiation dose. Due to the inter-effect of influencing CT parameters, traditional optimization methods rely on the testing of exhaustive combinations of these parameters. This poses a notable limitation due to the impracticality of exhaustive parameter testing. This study introduces a novel methodology leveraging Virtual Imaging Trials (VITs) and reinforcement learning to more efficiently optimize CT protocols. Computational phantoms with liver lesions were imaged using a validated CT simulator and reconstructed with a novel CT reconstruction Toolkit. The optimization parameter space included tube voltage, tube current, reconstruction kernel, slice thickness, and pixel size. The optimization process was done using a Proximal Policy Optimization (PPO) agent which was trained to maximize the Detectability Index (d’) of the liver lesion for each reconstructed image. Results showed that our reinforcement learning approach found the absolute maximum d’ across the test cases while requiring 79.7% fewer steps compared to an exhaustive search, demonstrating both accuracy and computational efficiency, offering a efficient and robust framework for CT protocol optimization. The flexibility of the proposed technique allows for use of varying image quality metrics as the objective metric to maximize for. Our findings highlight the advantages of combining VIT and reinforcement learning for CT protocol management.

Fenwick, David [Duke University Medical Center]↗

Experiments at Scale with In-Situ Visualization Using ParaView/Catalyst in RAGE

In this paper I describe some numerical experiments performed using the ParaView/Catalyst in-situ visualization infrastructure deployed in the Los Alamos RAGE radiation-hydrodynamics code to produce images from a running large scale 3D ICF simulation on the Cielo supercomputer at Los Alamos. The detailed procedures for the creation of the visualizations using ParaView/Catalyst are discussed and several images sequences from the ICF simulation problem produced with the in-situ method are presented. My impressions and conclusions concerning the use of the in-situ visualization method in RAGE are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetoacoustic tomography with magnetic induction for high-resolution bioimepedance imaging through vector source reconstruction under the static field of MRI magnet

Purpose: Magnetoacoustic tomography with magnetic induction (MAT-MI) is an imaging modality to reconstruct the electrical conductivity of biological tissue based on the acoustic measurements of Lorentz force induced tissue vibration. This study presents the feasibility of the authors' new MAT-MI system and vector source imaging algorithm to perform a complete reconstruction of the conductivity distribution of real biological tissues with ultrasound spatial resolution. Methods: In the present study, using ultrasound beamformation, imaging point spread functions are designed to reconstruct the induced vector source in the object which is used to estimate the object conductivity distribution. Both numerical studies and phantom experiments are performed to demonstrate the merits of the proposed method. Also, through the numerical simulations, the full width half maximum of the imaging point spread function is calculated to estimate of the spatial resolution. The tissue phantom experiments are performed with a MAT-MI imaging system in the static field of a 9.4 T magnetic resonance imaging magnet. Results: The image reconstruction through vector beamformation in the numerical and experimental studies gives a reliable estimate of the conductivity distribution in the object with a ∼1.5 mm spatial resolution corresponding to the imaging system frequency of 500 kHz ultrasound. In addition, the experiment results suggest that MAT-MI under high static magnetic field environment is able to reconstruct images of tissue-mimicking gel phantoms and real tissue samples with reliable conductivity contrast. Conclusions: The results demonstrate that MAT-MI is able to image the electrical conductivity properties of biological tissues with better than 2 mm spatial resolution at 500 kHz, and the imaging with MAT-MI under a high static magnetic field environment is able to provide improved imaging contrast for biological tissue conductivity reconstruction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PDSS/IMC CIS user's guide

The Spacelab Payload Development Support System PDSS Image Motion Compensator (IMC) computer interface simulation (CIS) user's manual is given. The software provides a real time interface simulation for the following IMC subsystems: the Dry Rotor Reference Unit, the Advanced Star/Target Reference Optical sensor, the Ultra Violet imaging telescope, the Wisconson Ultraviolet Photopolarimetry Experiment, the Cruciform Power distributor, and the Spacelab Experiment Computer Operating System.

Source record↗

SU-E-J-136: Investigation Into Robustness of Stopping Power Calculated by DECT and SECT for Proton Therapy Treatment Planning

Purpose: To investigate the robustness of dual energy CT (DECT) and single energy CT (SECT) proton stopping power calibration techniques and quantify the associated errors when imaging a phantom differing in chemical composition to that used during stopping power calibration. Methods: The CIRS tissue substitute phantom was scanned in a CT-simulator at 90kV and 140kV. This image set was used to generate a DECT proton SPR calibration based on a relationship between effective atomic number and mean excitation energy. A SECT proton SPR calibration based only on Hounsfield units (HUs) was also generated. DECT and SECT scans of a second phantom of known density and chemical composition were performed. The SPR of the second phantom was calculated with the DECT approach (SPR-DECT),the SECT approach (SPR-SECT) and finally the known density and chemical composition of the phantom (SPR-ref). The DECT and SECT image sets were imported into the Pinnacle{sup 3} research release of proton therapy treatment planning. The difference in dose when exposed to a common pencil beam distribution was investigated. Results: SPR-DECT was found to be in better agreement with SPR-ref than SPR- SECT. The mean difference in SPR for all materials was 0.51% for DECT and 6.89% for SECT. With the exception of Teflon, SPR-DECT was found to agree with SPR-ref to within 1%. Significant differences in calculated dose were found when using the DECT image set or the SECT image set. Conclusion: The DECT calibration technique was found to be more robust to situations in which the physical properties of the test materials differed from the materials used during SPR calibration. Furthermore, it was demonstrated that the DECT and SECT SPR calibration techniques can Result in significantly different calculated dose distributions.

60 APPLIED LIFE SCIENCES↗

In Situ Real-Time Radiographic Study of Thin Film Formation Inside Rotating Hollow Spheres

Hollow spheres with uniform coatings on the inner surface have applications in optical devices, time- or site controlled drug release, heat storage devices, and target fabrication for inertial confinement fusion experiments. The fabrication of uniform coatings, which is often critical for the application performance, requires precise understanding and control over the coating process and its parameters. Here, we report on in-situ real-time radiography experiments that provide critical spatio-temporal information about the distribution of fluids inside hollow spheres during uniaxial rotation. Image analysis and computer fluid dynamics simulations were used to explore the effect of liquid viscosity and rotational velocity on the film uniformity. The data were then used to demonstrate the fabrication of uniform sol-gel chemistry derived porous polymer films inside 2mm inner diameter diamond shells.

aerogel↗

Digital Lunar Exploration Sites (DLES) Terrain Crafting

Humans will soon be returning to the surface of the Moon with NASA’s Artemis program. The Artemis program is an international collaboration that will consist of a complex series of space systems and missions to explore the lunar surface and pave the way for the future exploration of Mars. NASA and its partners rely heavily on simulation for lighting and navigation studies as well as training astronauts, flight controllers, and mission support staff. The NASA Exploration Systems Simulations (NExSyS) team in the Simulation and Graphics Branch (ER7) in the Engineering Directorate at NASA’s Johnson Space Center has built up many simulation products to support this effort, one of which is the Digital Lunar Exploration Sites (DLES). DLES is a collection of products used to simulate and render the lunar surface in a digital environment. We discussed and presented an overview of the DLES products at the 2022 IEEE Aerospace Conference in Big Sky, MT with a paper titled "Digital Lunar Exploration Sites". This “DLES Terrain Crafting” paper will expand on the information previously provided in “DLES” paper and dive deeper into the details of the terrain crafting process and the toolsets used to support this task. The best digital data currently available of the lunar surface is provided by the Lunar Reconnaissance Orbiter (LRO). Its Lunar Orbiter Laser Altimeter (LOLA) achieves an impressive resolution of 5m per pixel at the Lunar South Pole (LSP) and can generate datasets covering a large continuous region near the LSP. There are a few additional methods, such as Shape from Shading which can infer higher resolution data (up to 1m per pixel) from the LRO Narrow Angle Camera (NAC) images. However, surface-based simulations require higher-resolution data, and this paper will discuss the process of enhancing the terrain to meet that need. The process begins with capturing statistical data of craters in the regions of interest using images provided by the LRO NAC. This data is then used to scatter artificial features which are not captured in the truth data, resulting in an enhanced DEM with a much higher resolution of 20cm per pixel. Many tools were built up to assist in the creation of these artificial Digital Elevation Models (DEM), which this paper will discuss in detail. DEMs themselves are a very powerful representation of a planetary surface, and many operations and tools can utilize the data they contain. This paper includes a description of the rendering of the lunar surface in a graphics engine, generation of contact patches to simulate tire to ground interaction, and ray tracing utilities to model Line of Sight (LOS) interactions with the terrain. This paper will also explore some new tool sets currently under development which aim to utilize Machine Learning (ML) to assist in the identification of craters from LRO NAC imagery. While this is not a novel idea, the NExSyS team is developing a unique approach which may result in more robust identification of crater characteristics.

Artemis↗

A sampling procedure to guide the collection of narrow-band, high-resolution spatially and spectrally representative reflectance data

A multistage sampling procedure using image processing, geographical information systems, and analytical photogrammetry is presented which can be used to guide the collection of representative, high-resolution spectra and discrete reflectance targets for future satellite sensors. The procedure is general and can be adapted to characterize areas as small as minor watersheds and as large as multistate regions. Beginning with a user-determined study area, successive reductions in size and spectral variation are performed using image analysis techniques on data from the Multispectral Scanner, orbital and simulated Thematic Mapper, low altitude photography synchronized with the simulator, and associated digital data. An integrated image-based geographical information system supports processing requirements.

Brand, R. R.↗

Domain Adaptation for Measurements of Strong Gravitational Lenses

Upcoming surveys are predicted to discover galaxy-scale strong lenses on the order of 10\textsuperscript{5}, making deep learning methods necessary in lensing data analysis. Currently, there is insufficient real lensing data to train deep learning algorithms, but the alternative of training only on simulated data results in poor performance on real data. Domain Adaptation may be able to bridge the gap between simulated and real datasets. We utilize domain adaptation for the estimation of Einstein radius ($\Theta_E$) in simulated galaxy-scale gravitational lensing images with different levels of observational realism. We evaluate two domain adaptation techniques - Domain Adversarial Neural Networks (DANN) and Maximum Mean Discrepancy (MMD). We train on a source domain of simulated lenses and apply it to a target domain of lenses simulated to emulate noise conditions in the Dark Energy Survey (DES). We show that both domain adaptation techniques can significantly improve the model performance on the more complex target domain dataset. This work is the first application of domain adaptation for a regression task in strong lensing imaging analysis. Our results show the potential of using domain adaptation to perform analysis of future survey data with a deep neural network trained on simulated data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Domain Adaptation for Measurements of Strong Gravitational Lenses

Upcoming surveys are predicted to discover galaxy-scale strong lenses on the order of $10^5$, making deep learning methods necessary in lensing data analysis. Currently, there is insufficient real lensing data to train deep learning algorithms, but the alternative of training only on simulated data results in poor performance on real data. Domain Adaptation may be able to bridge the gap between simulated and real datasets. We utilize domain adaptation for the estimation of Einstein radius ($\Theta_E$) in simulated galaxy-scale gravitational lensing images with different levels of observational realism. We evaluate two domain adaptation techniques - Domain Adversarial Neural Networks (DANN) and Maximum Mean Discrepancy (MMD). We train on a source domain of simulated lenses and apply it to a target domain of lenses simulated to emulate noise conditions in the Dark Energy Survey (DES). We show that both domain adaptation techniques can significantly improve the model performance on the more complex target domain dataset. This work is the first application of domain adaptation for a regression task in strong lensing imaging analysis. Our results show the potential of using domain adaptation to perform analysis of future survey data with a deep neural network trained on simulated data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel lobster-eye imaging system based on Schmidt-type objective for X-ray-backscattering inspection

This paper presents a novel lobster-eye imaging system for X-ray-backscattering inspection. The system was designed by modifying the Schmidt geometry into a treble-lens structure in order to reduce the resolution difference between the vertical and horizontal directions, as indicated by ray-tracing simulations. The lobster-eye X-ray imaging system is capable of operating over a wide range of photon energies up to 100 keV. In addition, the optics of the lobster-eye X-ray imaging system was tested to verify that they meet the requirements. X-ray-backscattering imaging experiments were performed in which T-shaped polymethyl-methacrylate objects were imaged by the lobster-eye X-ray imaging system based on both the double-lens and treble-lens Schmidt objectives. The results show similar resolution of the treble-lens Schmidt objective in both the vertical and horizontal directions. Moreover, imaging experiments were performed using a second treble-lens Schmidt objective with higher resolution. The results show that for a field of view of over 200 mm and with a 500 mm object distance, this lobster-eye X-ray imaging system based on a treble-lens Schmidt objective offers a spatial resolution of approximately 3 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-177: Clinical Experience with Spirometer Guided Breath Hold Lung SBRT

Purpose: Tumor motion in lung SBRT is typically managed by creating an internal target volume (ITV) based on 4D-CT information. Another option, which may reduce lung dose and imaging artifact, is to use a breath hold (BH) during simulation and delivery. Here we evaluate the reproducibility of tumor position at repeated BH using a newly released spirometry system. Methods: Three patients underwent multiple BH CT’s at simulation. All patients underwent a BH cone beam CT (CBCT) prior to each treatment. All image sets were registered to a patient’s first simulation CT based on local bony anatomy. The gross tumor volume (GTV), and the diaphragm or the apex of the lung were contoured on the first image set and expanded in 1 mm increments until the GTVs and diaphragms on all image sets were included inside an expanded structure. The GTV and diaphragm margins necessary to encompass the structures were recorded. Results: The first patient underwent 2 BH CT’s and fluoroscopy at simulation, the remaining patients underwent 3 BH CT’s at simulation. In all cases the GTV’s remained within 1 mm expansions and the diaphragms remained within 2 mm expansions on repeat scans. Each patient underwent 3 daily BH CBCT’s. In all cases the GTV’s remained within a 2 mm expansions, and the diaphragms (or lung apex in one case) remained within 2 mm expansions at daily BH imaging. Conclusions: These case studies demonstrate spirometry as an effective tool for limiting tumor motion (and imaging artifact) and facilitating reproducible tumor positioning over multiple set-ups and BH’s. This work was partially supported by Qfix.

60 APPLIED LIFE SCIENCES↗

Cone-Beam Computed Tomography Internal Motion Tracking Should Be Used to Validate 4-Dimensional Computed Tomography for Abdominal Radiation Therapy Patients

Purpose: To demonstrate that fiducial tracking during pretreatment Cone-Beam CT (CBCT) can accurately measure tumor motion and that this method should be used to validate 4-dimensional CT (4DCT) margins before each treatment fraction. Methods and Materials: For 31 patients with abdominal tumors and implanted fiducial markers, tumor motion was measured daily with CBCT and fluoroscopy for 202 treatment fractions. Fiducial tracking and maximum-likelihood algorithms extracted 3-dimensional fiducial trajectories from CBCT projections. The daily internal margin (IM) (ie, range of fiducial motion) was calculated for CBCT and fluoroscopy as the 5th-95th percentiles of displacement in each cardinal direction. The planning IM from simulation 4DCT (IM{sub 4DCT}) was considered adequate when within ±1.2 mm (anterior–posterior, left–right) and ±3 mm (superior–inferior) of the daily measured IM. We validated CBCT fiducial tracking as an accurate predictive measure of intrafraction motion by comparing the daily measured IM{sub CBCT} with the daily IM measured by pretreatment fluoroscopy (IM{sub pre-fluoro}); these were compared with pre- and posttreatment fluoroscopy (IM{sub fluoro}) to identify those patients who could benefit from imaging during treatment. Results: Four-dimensional CT could not accurately predict intrafractional tumor motion for ≥80% of fractions in 94% (IM{sub CBCT}), 97% (IM{sub pre-fluoro}), and 100% (IM{sub fluoro}) of patients. The IM{sub CBCT} was significantly closer to IM{sub pre-fluoro} than IM{sub 4DCT} (P<.01). For patients with median treatment time t < 7.5 minutes, IM{sub CBCT} was in agreement with IM{sub fluoro} for 93% of fractions (superior–inferior), compared with 63% for the t > 7.5 minutes group, demonstrating the need for patient-specific intratreatment imaging. Conclusions: Tumor motion determined from 4DCT simulation does not accurately predict the daily motion observed on CBCT or fluoroscopy. Cone-beam CT could replace fluoroscopy for pretreatment verification of simulation IM{sub 4DCT}, reducing patient setup time and imaging dose. Patients with treatment time t > 7.5 minutes could benefit from the addition of intratreatment imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗