Search NASA⌕ Search

SEARCH · Search NASA

Results for “ionization potentials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

TPSAS-NF1676L-33911-DND

Future NASA missions for space exploration require key technological elements that must provide sustainability, survivability and operational envelope in extreme environments, such as the high and low extremes in pressures and temperatures, ionizing radiations, chemical and/or physical corrosion, and hypervelocity particles. Advanced multifunctional materials enable revolutionary design schemes for future aerospace vehicles and structures for the extreme environments of NASA missions. Recent studies of nanocomposite materials have shown the potential for both structural integrity and multifunctional capabilities, such as sensing, actuating, health monitoring, radiation shielding, energy harvesting, thermal management, and thermal protection in extreme environments. After the advent of carbon nanotube (CNT) in 1991, scientists predicted that boron and nitrogen, carbons immediate neighbors on the periodic chart, might also form perfect nanotubes, namely boron nitride nanotubes (BNNTs). The discovery and progress of a new catalyst-free method for synthesizing highly crystalline, very long, and small diameter BNNTs under a high temperature and pressure (HTP) environment have enabled new applications for multifunctional materials. The white color BNNTs offer extraordinary properties including neutron radiation shielding, piezoelectricity, electrostriction, high thermal oxidative stability (>800?C in air), not present in CNTs, as well as excellent mechanical strength and toughness, equivalent to CNTs. The characteristics of the novel BNNTs and their composites along with CNT composites are discussed in this presentation along with their potential aerospace applications in extreme environments.

Cheol Park↗

TPSAS-NF1676L-35440-DND

Future NASA missions for space exploration require key technological elements that must provide sustainability, survivability and operational envelope in extreme environments, such as the high and low extremes in pressures and temperatures, ionizing radiations, chemical and/or physical corrosion, and hypervelocity particles. Advanced multifunctional materials enable revolutionary design schemes for future aerospace vehicles and structures for the extreme environments of NASA missions. Recent studies of nanocomposite materials have shown the potential for both structural integrity and multifunctional capabilities, such as sensing, actuating, health monitoring, radiation shielding, energy harvesting, thermal management, and thermal protection in extreme environments. After the advent of carbon nanotube (CNT) in 1991, scientists predicted that boron and nitrogen, carbon's immediate neighbors on the periodic chart, might also form perfect nanotubes, namely boron nitride nanotubes (BNNTs). The discovery and progress of a new catalyst-free method for synthesizing highly crystalline, very long, and small diameter BNNTs under a high temperature and pressure (HTP) environment have enabled new applications for multifunctional materials. The white color BNNTs offer extraordinary properties including neutron radiation shielding, piezoelectricity, electrostriction, high thermal oxidative stability(>800 C in air), not present in CNTs, as well as excellent mechanical strength and toughness, equivalent to CNTs. The characteristics of the BNNTs and their composites along with CNT composites are discussed in this presentation along with their potential aerospace applications in extreme environments.

Cheol Park↗

High Temperature Pressure (HTP) Boron Nitride Nanotube (BNNT): Discovery and Commercialization

Future NASA missions for space exploration require key technological elements that must provide sustainability, survivability and operational envelope in extreme environments, such as the high and low extremes in pressures and temperatures, ionizing radiations, chemical and/or physical corrosion, and hypervelocity particles. Advanced multifunctional materials enable revolutionary design schemes for future aerospace vehicles and structures for the extreme environments of NASA missions. Recent studies of nanocomposite materials have shown the potential for both structural integrity and multifunctional capabilities, such as sensing, actuating, health monitoring, radiation shielding, energy harvesting, thermal management, and thermal protection in extreme environments. After the advent of carbon nanotube (CNT) in 1991, scientists predicted that boron and nitrogen, carbons immediate neighbors on the periodic chart, might also form perfect nanotubes, namely boron nitride nanotubes (BNNTs). The discovery and progress of a new catalyst-free method for synthesizing highly crystalline, very long, and small diameter BNNTs under a high temperature and pressure (HTP) environment have enabled new applications for multifunctional materials. The white color BNNTs offer extraordinary properties including neutron radiation shielding, piezoelectricity, electrostriction, high thermal oxidative stability (>800C in air), not present in CNTs, as well as excellent mechanical strength and toughness, equivalent to CNTs. The characteristics of the BNNTs and their composites along with CNT composites are discussed in this presentation along with their potential aerospace applications in extreme environments.

Cheol Park↗

Experimental study of ECH pre-ionization on J-TEXT

An experimental study on electron cyclotron heating (ECH) pre-ionization has been conducted on J-TEXT in support of the joint experiment research for ITER plasma initiation. In this experiment, ECH power was injected to the vessel before the application of loop voltage ionize the neutral gas and form the initial plasma or so-called pre-plasma. The impact of several significant factors, such as magnetic field configuration, pre-fill gas pressure, ECH toroidal injection angle and ECH power on the evolution of pre-plasma are systematically studied, aiming to identify shared features, clarify their potential relationship and optimize the discharge parameters to generate a rather high pre-plasma density. By separating ECH power from the inductive start-up, the effect of pre-plasma on tokamak start-up can be observed. A dynamic magnetic configuration facilitates the transition of pre-plasma to tokamak plasma. To assess the influence of pre-plasma density on tokamak start-up, two kinds of magnetic field configurations are examined. While the effect of different pre-plasma densities on tokamak start-up is negligible, a significant difference is observed between pure ohmic start-up and start-up with pre-ionization. The studies presented here show evolutionary trends and threshold values needed to optimize ECH pre-ionization and also a feasible way to improve pre-plasma density and a configuration to stabilize pre-plasma for transition. Eventually, these results may contribute to multi-machine research and physics analysis that can assist ITER with its optimal preparation for first plasma operation.

ECH↗

DEEPLY EMBEDDED PROTOSTELLAR POPULATION IN THE 20 km s{sup −1} CLOUD OF THE CENTRAL MOLECULAR ZONE

We report the discovery of a population of deeply embedded protostellar candidates in the 20 km s{sup −1} cloud, one of the massive molecular clouds in the Central Molecular Zone (CMZ) of the Milky Way, using interferometric submillimeter continuum and H{sub 2}O maser observations. The submillimeter continuum emission shows five 1 pc scale clumps, each of which further fragments into several 0.1 pc scale cores. We identify 17 dense cores, among which 12 are gravitationally bound. Among the 18 H{sub 2}O masers detected, 13 coincide with the cores and probably trace outflows emanating from the protostars. There are also 5 gravitationally bound dense cores without H{sub 2}O maser detection. In total, the 13 masers and 5 cores may represent 18 protostars with spectral types later than B1 or potentially growing more massive stars at earlier evolutionary stages, given the non-detection in the centimeter radio continuum. In combination with previous studies of CH{sub 3}OH masers, we conclude that the star formation in this cloud is at an early evolutionary phase, before the presence of any significant ionizing or heating sources. Our findings indicate that star formation in this cloud may be triggered by a tidal compression as it approaches pericenter, similar to the case of G0.253+0.016 but with a higher star formation rate, and demonstrate that high angular resolution, high-sensitivity maser, and submillimeter observations are promising techniques to unveil deeply embedded star formation in the CMZ.

79 ASTRONOMY AND ASTROPHYSICS↗

New loading method for high precision Sm isotope analysis of nuclear materials using thermal ionization mass spectrometry

This work demonstrates an analytical protocol for high precision Sm isotope analysis by thermal ionization mass spectrometry (TIMS) using a Pt activator. Here, the method permits precise measurements of small aliquots (1–20 ng) of Sm on single Re filament using a modified static-total evaporation technique. This study represents the first attempt to use such protocols for Sm isotope analyses while reducing the loading size of Sm for TIMS. The method could potentially be deployed to study geological, meteorites and lunar samples containing low Sm concentrations, to monitor neutron irradiation exposure based on 149,150 Sm, or to measure Sm isotopic composition in other types of nuclear samples.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Feasibility Study of Glass Dosimeter for In Vivo Measurement: Dosimetric Characterization and Clinical Application in Proton Beams

Purpose: To evaluate the suitability of the GD-301 glass dosimeter for in vivo dose verification in proton therapy. Methods and Materials: The glass dosimeter was analyzed for its dosimetrics characteristic in proton beam. Dosimeters were calibrated in a water phantom using a stairlike holder specially designed for this study. To determine the accuracy of the glass dosimeter in proton dose measurements, we compared the glass dosimeter and thermoluminescent dosimeter (TLD) dose measurements using a cylindrical phantom. We investigated the feasibility of the glass dosimeter for the measurement of dose distributions near the superficial region for proton therapy plans with a varying separation between the target volume and the surface of 6 patients. Results and Discussion: Uniformity was within 1.5%. The dose-response has good linearity. Dose-rate, fading, and energy dependence were found to be within 3%. The beam profile measured using the glass dosimeter was in good agreement with the profile obtained from the ionization chamber. Depth-dose distributions in nonmodulated and modulated proton beams obtained with the glass dosimeter were estimated to be within 3%, which was lower than those with the ionization chamber. In the phantom study, the difference of isocenter dose between the delivery dose calculated by the treatment planning system and that measured by the glass dosimeter was within 5%. With in vivo dosimetry, the calculated surface doses overestimated measurements by 4%-16% using glass dosimeter and TLD. Conclusion: It is recommended that bolus be added for these clinical cases. We also believe that the glass dosimeter has considerable potential for use with in vivo patient proton dosimetry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

What happens when spins meet for ionizing radiation dosimetry?

Electron spin resonance (ESR) and magnetic resonance imaging (MRI) can be used to measure radiation dose deposited in different milieu through its effects. Radiation can break chemical bonds and if they produce stable free radicals, ESR can measure their concentration through their spins and a dose can be inferred. Ionizing radiation can also promote polymerization and in this case proton relaxation times can be measured and an image weighed by T2 can be produced giving spatial information about dose. A review of the basics of these applications is presented concluding with an end-to-end test using a composite Gel-Alanine phantom to validate 3-dimensionally dose distribution delivered in a simulation of Volume Modulated Arch Therapy on the simultaneous treatment of multiple brain metastases. The results obtained with the gel and alanine dosimeters are consistent with the expected by the treatment planning system, showing the potential of this multidosimetric approach and validating dosimetrically the multiple brain metastases treatment using VMAT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling weakly-ionized plasmas in magnetic field: A new computationally-efficient approach

Despite its success at simulating accurately both non-neutral and quasi-neutral weakly-ionized plasmas, the drift-diffusion model has been observed to be a particularly stiff set of equations. Recently, it was demonstrated that the stiffness of the system could be relieved by rewriting the equations such that the potential is obtained from Ohm's law rather than Gauss's law while adding some source terms to the ion transport equation to ensure that Gauss's law is satisfied in non-neutral regions. Although the latter was applicable to multicomponent and multidimensional plasmas, it could not be used for plasmas in which the magnetic field was significant. This paper hence proposes a new computationally-efficient set of electron and ion transport equations that can be used not only for a plasma with multiple types of positive and negative ions, but also for a plasma in magnetic field. Because the proposed set of equations is obtained from the same physical model as the conventional drift-diffusion equations without introducing new assumptions or simplifications, it results in the same exact solution when the grid is refined sufficiently while being more computationally efficient: not only is the proposed approach considerably less stiff and hence requires fewer iterations to reach convergence but it yields a converged solution that exhibits a significantly higher resolution. The combined faster convergence and higher resolution is shown to result in a hundredfold increase in computational efficiency for some typical steady and unsteady plasma problems including non-neutral cathode and anode sheaths as well as quasi-neutral regions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single-Cell Metabolic Profiling: Metabolite Formulas from Isotopic Fine Structures in Heterogeneous Plant Cell Populations

Characterization of the metabolic heterogeneity in cell populations requires the analysis of single cells. Most current methods in single-cell analysis rely on cell manipulation, potentially altering the abundance of metabolites in individual cells. Small sample volume and the chemical diversity of metabolites are additional challenges in single-cell metabolomics. Here, we describe the combination of fiber-based laser ablation electrospray ionization (f-LAESI) with 21 tesla Fourier transform ion cyclotron resonance mass spectrometry (21TFTICR-MS) for in situ single-cell metabolic profiling in plant tissue. Single plant cells infected by bacteria were selected and sampled directly from the tissue without cell manipulation through mid-infrared ablation with a fine optical fiber tip for ionization by f-LAESI. Finally, ultrahigh performance 21T-FTICR-MS enabled the simultaneous capture of isotopic fine structures (IFSs) for 47 known and 11 unknown compounds, thus elucidating their elemental compositions from single cells, and providing information on metabolic heterogeneity in the cell population.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Skipper-CCD sensors for the Oscura experiment: requirements and preliminary tests

Oscura is a proposed multi-kg skipper-CCD experiment designed for a dark matter (DM) direct detection search that will reach unprecedented sensitivity to sub-GeV DM-electron interactions with its 10 kg detector array. Oscura is planning to operate at SNOLAB with 2070 m overburden, and aims to reach a background goal of less than one event in each electron bin in the 2–10 electron ionization-signal region for the full 30 kg-year exposure, with a radiation background rate of 0.01 dru.[1 dru (differential rate unit) corresponds to 1 event/kg/day/keV.] In order to achieve this goal, Oscura must address each potential source of background events, including instrumental backgrounds. In this work, we discuss the main instrumental background sources and the strategy to control them, establishing a set of constraints on the sensors' performance parameters. We present results from the tests of the first fabricated Oscura prototype sensors, evaluate their performance in the context of the established constraints and estimate the Oscura instrumental background based on these results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Issues in Low Dose Radiation Biology: The Controversy Continues. A Perspective

Both natural and man-made sources of ionizing radiation contribute to human exposure and consequently pose a risk to human health. Much of this is unavoidable, e.g., natural background radiation, and as the use of radiation in modern medicine and industry increases so does the potential health risk. This perspective reflects the author’s view of current issues in low dose radiation biology research, highlights some of the controversies therein, and suggests areas of future research to address these issues. The views expressed here are the authors own and do not represent any institution, organization or funding body.

Morgan, William F.↗

The origin of double-peaked narrow lines in active galactic nuclei. II. Kinematic classifications for the population at z < 0.1

We present optical long-slit observations of the complete sample of 71 Type 2 active galactic nuclei (AGNs) with double-peaked narrow emission lines at z < 0.1 in the Sloan Digital Sky Survey. Double-peaked emission lines are produced by a variety of mechanisms including disk rotation, kiloparsec-scale dual AGNs, and narrow-line region (NLR) kinematics (outflows or inflows). We develop a novel kinematic classification technique to determine the nature of these objects using long-slit spectroscopy alone. We determine that 86% of the double-peaked profiles are produced by moderate-luminosity AGN outflows, 6% are produced by rotation, and 8% are ambiguous. While we are unable to directly identify dual AGNs with long-slit data alone, we explore their potential kinematic classifications with this method. We also find a positive correlation between the NLR size and luminosity of the AGN NLRs (R {sub NLR}∝ L{sub [O III]}{sup 0.21±0.05}), indicating a clumpy two-zone ionization model for the NLR.

79 ASTRONOMY AND ASTROPHYSICS↗

The induced environment around Space Station

The potential impact of the International Space Station on its immediate environment is discussed, summarizing the results of recent investigations by NASA working groups. Consideration is given to the neutral-gas environment, induced photon emission, particulate contamination, the ionized environment, the Induced-environment Monitoring Package proposed for inclusion in the Space Station equipment, and recommendations for further research. Diagrams, drawings, graphs, and tables of numerical data are provided.

Torr, Marsha R.↗

Chemical Characterization and Thermal Stressing Studies of Perfluorohexane Fluids for Space-Based Applications

Perfluorohexane (PFH), C6F14, is a perfluorocarbon fluid. Several PFH fluids with different isomer concentrations were evaluated for use in an upcoming NASA space experiment. Samples tested included two commercially obtained high-purity n-perfluorohexane (n-PFH) fluids and a technical grade mixture of C6F14 branched and linear isomers (FC-72(TradeMark)). These fluids were evaluated for exact chemical composition, impurity purity and high temperature degradation behavior (pyrolysis). Our investigation involved simulated thermal stressing studies of PFH fluids under conditions likely to occur in the event of an atmospheric breach within the International Space Station (ISS) and subsequent exposure of the vapors to the high temperature and catalyst present in its Trace Contaminant Control Subsystem (TCCS). Exposure to temperatures in the temperature range of 200-450 C in an inert or oxidizing atmosphere, with and without the presence of catalyst was investigated. The most aggressive conditions studied were exposure of PFH vapors to 450 C in air and in the presence of TCCS (palladium) catalyst. Gas chromatography-mass spectrometry (GC-MS) and gas chromatography (GC) analyses were conducted on the perfluorohexane samples before and after pyrolysis. The FC-72 and n-PFH samples showed no significant degradation following pyrolysis even under the most aggressive study conditions. Some trace level impurities associated with the PFH samples such as linear perfluorocarbon monohydrides or monoiodides were destroyed by pyrolysis at the upper limit. Other trace level impurities such as olefinic or cycloolefinic perfluorocarbons were converted into oxidation products by pyrolysis. The purity of PFH following pyrolysis actually increased slightly as a consequence since these trace contaminants were effectively scrubbed from the samples. However, since the initial concentrations of the thermally-impacted impurities were so low, the net effect was trivial. A potential byproduct of exposure of perfluorohexane fluids to high temperatures is the production of perfluoroisobutene (PFiB), which is extremely toxic. An ultra-high sensitivity PFiB-specific analysis based on GC-MS with negative ion chemical ionization (NICI) detection was used to evaluate the samples following thermal stressing. The perfluorohexanes examined here under conditions reflective of the ISS TCCS environment showed no signs of PFiB production with an analytical detection limit of 10 part per billion (ppb v/v).

Arnold, William A.↗

The OASIS Mission

The Orbiting Astrophysical Observatory in Space (OASIS) is a mission to investigate Galactic Cosmic Rays (GCRs), a major feature of our galaxy. OASIS will use measurements of GCRs to determine the cosmic ray source, where they are accelerated, to investigate local accelerators and to learn what they can tell us about the interstellar medium and the processes that occur in it. OASIS will determine the astrophysical sources of both the material and acceleration of GCRs by measuring the abundances of the rare actinide nuclei and make direct measurements of the spectrum and anisotropy of electrons at energies up to approx.10 TeV, well beyond the range of the Fermi and AMS missions. OASIS has two instruments. The Energetic Trans-Iron Composition Experiment (ENTICE) instrument measures elemental composition. It resolves individual elements with atomic number (Z) from 10 to 130 and has a collecting power of 60m2.str.yrs, >20 times larger than previous instruments, and with improved resolution. The sample of 10(exp 10) GCRs collected by ENTICE will include .100 well-resolved actinides. The High Energy Particle Calorimeter Telescope (HEPCaT) is an ionization calorimeter that will extend the electron spectrum into the TeV region for the first time. It has 7.5 sq m.str.yrs of collecting power. This talk will describe the scientific objectives of the OASIS mission and its discovery potential. The mission and its two instruments which have been designed to accomplish this investigation will also be described.

Adams, James H., Jr.↗

AS-2, a novel inhibitor of p53-dependent apoptosis, prevents apoptotic mitochondrial dysfunction in a transcription-independent manner and protects mice from a lethal dose of ionizing radiation

Highlights: • A bidentate HQ derivative, AS-2, suppresses p53-dependent apoptosis by DNA damage. • AS-2 does not significantly affect nuclear p53 response. • UV-excited blue emission of AS-2 clearly showed its extranuclear localization. • AS-2 prevents mitochondrial dysfunction despite the increase of mitochondrial p53. • AS-2 protects mice from a radiation dose that causes lethal hematopoietic syndrome. - Abstract: In a previous study, we reported that some tetradentate zinc(II) chelators inhibit p53 through the denaturation of its zinc-requiring structure but a chelator, Bispicen, a potent inhibitor of in vitro apoptosis, failed to show any efficient radioprotective effect against irradiated mice because the toxicity of the chelator to mice. The unsuitability of using tetradentate chelators as radioprotectors prompted us to undertake a more extensive search for p53-inhibiting agents that are weaker zinc(II) chelators and therefore less toxic. Here, we show that an 8-hydroxyquinoline (8HQ) derivative, AS-2, suppresses p53-dependent apoptosis through a transcription-independent mechanism. A mechanistic study using cells with different p53 characteristics revealed that the suppressive effect of AS-2 on apoptosis is specifically mediated through p53. In addition, AS-2 was less effective in preventing p53-mediated transcription-dependent events than pifithrin-μ (PFTμ), an inhibitor of transcription-independent apoptosis by p53. Fluorescence visualization of the extranuclear distribution of AS-2 also supports that it is ineffective on the transcription-dependent pathway. Further investigations revealed that AS-2 suppressed mitochondrial apoptotic events, such as the mitochondrial release of intermembrane proteins and the loss of mitochondrial membrane potential, although AS-2 resulted in an increase in the mitochondrial translocation of p53 as opposed to the decrease of cytosolic p53, and did not affect the apoptotic interaction of p53 with Bcl-2. AS-2 also protected mice that had been exposed to a lethal dose of ionizing radiation. Our findings indicate that some types of bidentate 8HQ chelators could serve as radioprotectors with no substantial toxicity in vivo.

60 APPLIED LIFE SCIENCES↗

Design Characteristics to Eliminate the Need for Parameter Optimization in Nanoflow ESI-MS

The sampling efficiency in electrospray ionization-mass spectrometry (ESI-MS) can be improved by decreasing the liquid flow rate to the nanoflow regime, where it is possible to draw a large fraction of the ESI plume into the mass spectrometer. This mode of operation is typically more difficult than ESI-MS at higher flow rates because it requires careful optimization of a number of parameters to achieve optimal sampling efficiency. In this work, we screened the relative impact on signal intensity and spray stability of factors that included sprayer position, spray electrode protrusion, sprayer tip shape, spray angle relative to the MS inlet, nebulizer gas flow rate, ESI potential, and means for generating the electric field to initiate electrospray. Based on the screening results, we explore the possibility of providing fixed optimal values for many of the key source parameters to eliminate much of the tuning that is required for conventional nanoflow sources. This approach has potential to greatly simplify nanoflow ESI-MS, while providing optimized sensitivity, stability, and robustness, with decreased variability between analyses. .

77 NANOSCIENCE AND NANOTECHNOLOGY↗