Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Applications of parameter estimation in the study of spinning airplanes

Spinning airplanes offer challenges to estimating dynamic parameters because of the nonlinear nature of the dynamics. In this paper, parameter estimation techniques are applied to spin flight test data for estimating the error in measuring post-stall angles of attack, deriving Euler angles from angular velocity data, and estimating nonlinear aerodynamic characteristics. The value of the scale factor for post-stall angles of attack agrees closely with that obtained from special wind-tunnel tests. The independently derived Euler angles are seen to be valid in spite of steep pitch angles. Estimates of flight derived nonlinear aerodynamic parameters are evaluated in terms of the expected fit error.

W Taylor, L., Jr.↗

The Mass–Concentration Relation and the Stellar-to-halo Mass Ratio in the CFHT Stripe 82 Survey

We present a new measurement of the mass–concentration relation and the stellar-to-halo mass ratio over the halo-mass range 5 × 10{sup 12} to 2 × 10{sup 14} M {sub ⊙}. To achieve this, we use weak lensing measurements from the Canada–France–Hawaii Telescope Stripe 82 Survey (CS82), combined with the central galaxies from the redMaPPer cluster catalog and the LOWZ/CMASS galaxy sample of the Sloan Digital Sky Survey-III Baryon Oscillation Spectroscopic Survey Tenth Data Release. The stacked lensing signals around these samples are modeled as a sum of contributions from the central galaxy, its dark matter halo, and the neighboring halos, as well as a term for possible centering errors. We measure the mass–concentration relation: c{sub 200c}(M)=A(((M{sub 200c})/(M{sub 0}))){sup B} with A = 5.24 ± 1.24, B = −0.13 ± 0.10 for 0.2 < z < 0.4, and A = 6.61 ± 0.75, B = −0.15 ± 0.05 for 0.4 < z < 0.6. These amplitudes and slopes are completely consistent with predictions from recent simulations. We also measure the stellar-to-halo mass ratio for our samples, and find results consistent with previous measurements from lensing and other techniques.

79 ASTRONOMY AND ASTROPHYSICS↗

Measuring interstellar grains from the haloes of binary X-ray sources

Coherent forward scattering of X-rays by interstellar grains creates a halo around the X-ray image of a compact source. The fractional halo brightness at 2 keV is typically of order 10% moderately reddened galactic sources. The angular brightness distribution of the halo, which extends over several arcminutes, indicates the size distribution of the grains, and the spectrum of the halo indicates the composition of the grains. The halo will persist for several hours after the point source vanishes during an eclipse of a binary source; this provides a way to avoid systematic errors in measuring halo brightness due to an extended point response function of the X-ray telescope. Indeed, it is possilbe to infer the size distribution and composition of the grains without an imaging X-ray telescope by observing the time-dependence of the halo spectrum during eclipse.

Xu, Y.↗

Error-correcting Bacon-Shor code with continuous measurement of noncommuting operators

We analyze the continuous operation of the nine-qubit error correcting Bacon-Shor code with all noncommuting gauge operators measured at the same time. The error syndromes are continuously monitored using cross-correlations of sets of three measurement signals. We calculate the logical error rates due to $X$, $Y$ and $Z$ errors in the physical qubits and compare the continuous implementation with the discrete operation of the code. We find that both modes of operation exhibit similar performances when the measurement strength from continuous measurements is sufficiently strong. Here, we also estimate the value of the crossover error rate of the physical qubits, below which continuous error correction gives smaller logical error rates. Continuous operation has the advantage of passive monitoring of errors and avoids the need for additional circuits involving ancilla qubits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Functional representation of tissue phantom ratios for photon fields

Purpose: The tissue phantom ratio (TPR) is a common dosimetric quantity used in photon dose calculations. For small photon fields with side lengths less than 4 cm, TPR data hardly exist in literature. In this work, a self-contained functional representation of TPR is proposed, valid for the whole range of clinically relevant depth and field sizes. This is especially useful for small fields shaped by multileaf collimators. Methods: TPRs were measured for quadratic fields with side lengths between 0.4 and 18 cm. The measured data were fitted to a physically meaningful function taking electron buildup, buildup of scattered photons, beam attenuation, and beam hardening into account. The achievable accuracy was tested against measurement and data from the literature. Results: A set of parameters for the proposed function was derived for 6 and 10 MV beams. The comparison of the calculated and the measured data generally yielded a difference of less than 1%. For field sizes below 2 cm, a systematic discrepancy between the author's data and those from Cheng et al. [Med. Phys 34, 3149-3157 (2007)] was found. Conclusions: With the proposed model, TPRs can be calculated for the full range of field sizes and depths required by treatment planning system algorithms and monitor unit check programs with very high accuracy. The method is also useful in detecting and reducing errors in measurement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurements of the electron density and degree of plasma ionization in a plasma target based on a linear electric discharge in hydrogen

Laser interferometry methods were used to measure the density of free electrons and degree of plasma ionization in a hydrogen target intended for experiments on determining energy losses of heavy ion beams in an ionized matter. It is shown that the linear electron density can be varied in the range from 3.3 Multiplication-Sign 10{sup 17} to 1.3 Multiplication-Sign 10{sup 18} cm{sup -2} by varying the initial plasma parameters (the hydrogen pressure in the target and the discharge current). The error in measuring the linear electron density in the entire range of the varied plasma parameters was less than 1%. The maximum degree of plasma ionization achieved at the initial gas pressure of 1 mbar was 0.62 {+-} 0.05.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-J-177: A Computational Approach for Determination of Anisotropic PTV Margins Based On Statistical Shape Analysis for Prostate Cancer Radiotherapy

Purpose: Our aim of this study was to propose a computational approach for determination of anisotropic planning target volume (PTV) margins based on statistical shape analysis with taking into account time variations of clinical target volume (CTV) shapes for the prostate cancer radiation treatment planning (RTP). Methods: Systematic and random setup errors were measured using orthogonal projection and cone beam computed tomography (CBCT) images for data of 20 patients, who underwent the intensity modulated radiation therapy for prostate cancer. The low-risk, intermediate-risk, and high-risk CTVs were defined as only a prostate, a prostate plus proximal 1-cm seminal vesicles, and a prostate plus proximal 2-cm seminal vesicles, respectively. All CTV regions were registered with a reference CTV region with a median volume to remove the effect of the setup errors, and converted to a point distribution models. The systematic and random errors for translations of CTV regions were automatically evaluated by analyzing the movements of centroids of CTV regions. The random and systematic errors for shape variations of CTV regions were obtained from covariance matrices based on point distributions for the CTV contours on CBCT images of 72 fractions of 10 patients. Anisotropic PTV margins for 6 directions (right, left, anterior, posterior, superior and inferior) were derived by using Yoda’s PTV margin model. Results: PTV margins with and without shape variations were 5.75 to 8.03 mm and 5.23 to 7.67 mm for low-risk group, 5.87 to 8.33 mm and 5.23 to 7.67 mm for intermediate-risk group, and 5.88 to 8.25 mm and 5.29 to 7.82 mm for highrisk group, respectively. Conclusion: The proposed computational approach could be feasible for determination of the anisotropic PTV margins with taking into account CTV shape variations for the RTP.

60 APPLIED LIFE SCIENCES↗

Solar concentrator panel and gore testing in the JPL 25-foot space simulator

The optical imaging characteristics of parabolic solar concentrator panels (or gores) have been measured using the optical beam of the JPL 25-foot space simulator. The simulator optical beam has been characterized, and the virtual source position and size have been determined. These data were used to define the optical test geometry. The point source image size and focal length have been determined for several panels. A flux distribution of a typical solar concentrator has been estimated from these data. Aperture photographs of the panels were used to determine the magnitude and characteristics of the reflecting surface errors. This measurement technique has proven to be highly successful at determining the optical characteristics of solar concentrator panels.

Dennison, E. W.↗

Evidence for B - → τ - ν ¯ τ with a Hadronic Tagging Method Using the Full Data Sample of Belle

In this work, we measure the branching fraction of B - → τ - ν ¯ τ using the full Υ ( 4 S ) data sample containing 772 × 10 6 B B ¯ pairs collected with the Belle detector at the KEKB asymmetric-energy e + e - collider. Events with B B ¯ pairs are tagged by reconstructing one of the B mesons decaying into hadronic final states, and B - → τ - ν ¯ τ candidates are detected in the recoil. We discover evidence for B - → τ - ν ¯ τ with a significance of 3.0 standard deviations including systematic errors and measure a branching fraction B ( B - → τ - ν ¯ τ ) = [ 0.72 - 0.25 + 0.27 ( stat ) ± 0.11 ( syst ) ] × 10 - 4 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

In situ measurements of BrO during AASE II

BrO measured from the NASA ER-2 during Airborne Arctic Stratospheric Expedition (AASE) II exhibited a mean value (for 20-minute averages) of 5.4 +/- 0.3 pptv, with a standard deviation of 3.1 pptv. Ratios of BrO to available inorganic bromine (Br(sub y)) show only slight increases in polar regions relative to midlatitudes. A comparison between observed latitudinal and diurnal variations of this same ratio and that calculated by photochemical models shows reasonable agreement in behavior, but significant discrepancies in magnitude. It is unclear whether this difference is due to errors in measurements, models or both.

Avallone, L. M.↗

Design and analysis of a torsion braid pendulum displacement transducer

The dynamic properties at various temperatures of braids impregnated with polymer can be measured by using the braid as the suspension of a torsion pendulum. This report describes the electronic and mechanical design of a torsional braid pendulum displacement transducer which is an advance in the state of the art. The transducer uses a unique optical design consisting of refracting quartz windows used in conjunction with a differential photocell to produce a null signal. The release mechanism for initiating free torsional oscillation of the pendulum has also been improved. Analysis of the precision and accuracy of the transducer indicated that the maximum relative error in measuring torsional amplitude was approximately 0. A serious problem inherent in all instruments which use a torsional suspension was analyzed: misalignment of the physical and torsional axes of the torsional member which results in modulation of the amplitude of the free oscillation.

Rind, E.↗

Stereo depth distortions in teleoperation

In teleoperation, a typical application of stereo vision is to view a work space located short distances (1 to 3m) in front of the cameras. The work presented here treats converged camera placement and studies the effects of intercamera distance, camera-to-object viewing distance, and focal length of the camera lenses on both stereo depth resolution and stereo depth distortion. While viewing the fronto-parallel plane 1.4 m in front of the cameras, depth errors are measured on the order of 2cm. A geometric analysis was made of the distortion of the fronto-parallel plane of divergence for stereo TV viewing. The results of the analysis were then verified experimentally. The objective was to determine the optimal camera configuration which gave high stereo depth resolution while minimizing stereo depth distortion. It is found that for converged cameras at a fixed camera-to-object viewing distance, larger intercamera distances allow higher depth resolutions, but cause greater depth distortions. Thus with larger intercamera distances, operators will make greater depth errors (because of the greater distortions), but will be more certain that they are not errors (because of the higher resolution).

Diner, Daniel B.↗

EXPERIMENTAL DETERMINATION OF THE RATE CONSTANT FOR THE ASSOCIATIVE DETACHMENT REACTION H{sup -} + H -> H{sub 2} + e {sup -} AT 300 K

We have determined the rate constant for the associative detachment reaction of hydride ions with hydrogen atoms (H{sup -} + H -> H{sub 2} + e {sup -}) at 300 K to be 2.0 (+-0.6) x 10{sup -9} cm{sup 3} s{sup -1}, where the error bars represent the total absolute error and include 1sigma of the measured values; the error analysis is described in the Appendix. Experiments were carried out in a flowing afterglow instrument using the well-characterized reactions of Cl{sup -} + H and OH{sup -} + H to calibrate the concentration of hydrogen atoms. Our measurement represents a significant improvement over previous determinations and will reduce uncertainties in cosmological models that rely on this reaction rate constant.

79 ASTRONOMY AND ASTROPHYSICS↗

Individual Load Model Parameter Estimation in Distribution Systems Using Load Switching Events

There currently exists a mature literature on modeling the aggregate load of a distribution feeder by making use of measurements at its feeder-head at substation. The primary application of such feeder-aggregated load models is in sub-transmission or transmission system analysis. However, there is a growing need in practice also to model each individual load across the feeder. If available, such individual load models have applications in power distribution system analysis, e.g., to better integrate distributed energy resources or to improve power quality and reliability. Motivated by this observation, in this paper, we propose a new method for individual load modeling in power distribution systems. It works by using the measurements only at the feeder-head. It takes an innovative approach to analyzing the load switching events across the distribution feeder itself, instead of or in addition to relying on upstream voltage events that are commonly used in feeder-aggregated load modeling. By tracking the downstream load switching events, the proposed method can make a robust estimation of the ZIP load model parameters for all individual loads. The proposed method is examined on small illustrative test-feeders as well as the IEEE 33-bus test system under various operating scenarios. The adverse impact of errors in measurements and system parameters are also investigated on the performance of the developed load modeling method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

How to avoid multiple scattering in strongly scattering SANS and USANS samples

Small Angle Neutron Scattering (SANS) and Ultra Small Angle Neutron Scattering (USANS) are the only available experimental techniques to provide seamless non-destructive measurements of the geometry of the accessible and inaccessible pore structure of rocks from sub-nanopore size to the scale of macropores. They have therefore become the measurement of choice for tight reservoir rocks such as organic rich shales. A simplifying assumption in the analysis is, however, that during the path of neutrons through the sample each neutron is only scattered once. Shales are samples with a high scattering power and Multiple Scattering (MS) may occur which requires special modelling for deconvolution of the results. The approach to avoid MS is to simply reduce the sample thickness to <0.15–0.5 mm. Here, in this work, we present a systematic method on wavelength selection and preparation of samples to optimise extraction of microstructural data and minimise parasitic errors. Experimentally measured SAS transmission (TSAS) values are used as a practical criterion for estimation of the extent of MS. Generous beamtime allocations allowed robust testing revealing that sample thicknesses can be twice as thick as predicted using the standard protocol. Analysing thicker samples is particularly beneficial for statistically relevant characterisation of heterogeneous samples making the new protocol the method of choice for such samples.

(U)SANS↗

MEASUREMENT OF COSMIC MICROWAVE BACKGROUND POLARIZATION POWER SPECTRA FROM TWO YEARS OF BICEP DATA

Background Imaging of Cosmic Extragalactic Polarization (BICEP) is a bolometric polarimeter designed to measure the inflationary B-mode polarization of the cosmic microwave background (CMB) at degree angular scales. During three seasons of observing at the South Pole (2006 through 2008), BICEP mapped {approx}2% of the sky chosen to be uniquely clean of polarized foreground emission. Here, we present initial results derived from a subset of the data acquired during the first two years. We present maps of temperature, Stokes Q and U, E and B modes, and associated angular power spectra. We demonstrate that the polarization data are self-consistent by performing a series of jackknife tests. We study potential systematic errors in detail and show that they are sub-dominant to the statistical errors. We measure the E-mode angular power spectrum with high precision at 21 <= l <= 335, detecting for the first time the peak expected at l {approx} 140. The measured E-mode spectrum is consistent with expectations from a LAMBDACDM model, and the B-mode spectrum is consistent with zero. The tensor-to-scalar ratio derived from the B-mode spectrum is r = 0.02{sup +0.31}{sub -0.26}, or r < 0.72 at 95% confidence, the first meaningful constraint on the inflationary gravitational wave background to come directly from CMB B-mode polarization.

79 ASTRONOMY AND ASTROPHYSICS↗

Sensitivity analysis for airborne and spaceborne DIAL measurements of H2O profiles

Random and systematic error sourses are presently analyzed for atmospheric H2O detection in the vicinity of the 720 nm absorption bands with Differential Absorption Lidar (DIAL). Attention is given to the random errors due to undertainties in the measurement of the lidar signal and noise that are associated with the background and detector dark currents. Systematic errors are related to Doppler broadening due to backscattering from air molecules, the pressure shift of H2O lines, laser line distortions, spectral impurities, and laser tuning errors. Global measurements of H2O profiles from spaceborne DIAL systems are achievable with 200 m vertical x 10 km horizontal during nighttime, and 250 m vertical x 20 km horizontal during daytime.

Ismail, Syed↗

Stochastic Error Cancellation in Analog Quantum Simulation

Analog quantum simulation is a promising path towards solving classically intractable problems in many-body physics on near-term quantum devices. However, the presence of noise limits the size of the system and the length of time that can be simulated. In our work, we consider an error model in which the actual Hamiltonian of the simulator differs from the target Hamiltonian we want to simulate by small local perturbations, which are assumed to be random and unbiased. We analyze the error accumulated in observables in this setting and show that, due to stochastic error cancellation, with high probability the error scales as the square root of the number of qubits instead of linearly. We explore the concentration phenomenon of this error as well as its implications for local observables in the thermodynamic limit. Moreover, we show that stochastic error cancellation also manifests in the fidelity between the target state at the end of time-evolution and the actual state we obtain in the presence of noise. This indicates that, to reach a certain fidelity, more noise can be tolerated than implied by the worst-case bound if the noise comes from many statistically independent sources.

Analog quantum simulation↗