Optimization-Based Estimation of Microgrid Equivalent Parameters for Voltage and Frequency Dynamics.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Explore the source record for details and available documents.
Homogenized fuel assembly (FA) data is a typical input data for nodal codes. Generating that data, however, could be time-consuming. One of promising ways to mitigate the computational burden of generating macroscopic cross-sections is to use trained artificial neural network (ANN) models for predicting nuclear data. However, there is a challenge to make the model support variable FA geometry. In this work, two most common types of FA were combined in one ANN model. Since there could be multiple ways of converting 2-dimensional FA data into 1-dimensional input vector for ANN, three different approaches of data flattening were evaluated. The input parameters included each fuel pin enrichment, fuel temperature, moderator temperature and boron concentration. The output parameters were 2-group macroscopic cross-sections (XS) and pin power distribution (HFF). A fully connected deep neural network (DNN) model was trained and tested using pre-generated data obtained with lattice physics code STREAM. The results of this study showed no statistically significant difference in the accuracy of XS and HFF generation for all 3 tested input vector orders. This means that fully connected DNN for XS generation demonstrated input sequence invariance. Results of comparing predicted XS data with reference solutions were found sufficiently close considering the reduction of computation time offered by ANN. Mean relative difference (MRD) for all output XS parameters was found below 0.7%, while HFF MRD was found higher compared to XS values, in some cases slightly exceeding 1%, mostly near guide tube locations. (authors)
FRAM (Fixed-energy Response-function Analysis with Multiple efficiency) is a program developed at Los Alamos National Laboratory that determines actinide isotopic composition by analyzing gamma-ray spectra of special nuclear material. This report documents the creations of the parameter sets and the performance (bias and precision) of FRAM version 6.1, scheduled for release in late 2019 – early 2020.
This report presents an analysis of the performance of deployable energy systems comprised of wind energy systems integrated with diesel generators, photovoltaic systems, and battery storage to meet the load requirements of a representative U.S. Army forward operating base. The analysis is conducted using HOMER, a microgrid analysis software that can search through a wide range of parameters to design and optimize microgrid power systems. The search parameters include the system architecture, the wind and solar resources, and the availability of diesel fuel. The results of the analysis measure the relative performance of the different systems and environments in terms of the overall transportation cost to deploy the system and the ability to provide resilience in terms of meeting mission critical loads.
Abstract not provided.
Explore the source record for details and available documents.
Farming is using more of the land surface, as population increases and agriculture is increasingly applied for non-nutritional purposes such as biofuel production. This agricultural expansion exerts an increasing impact on the terrestrial carbon cycle. In order to understand the impact of such processes, the Community Land Model (CLM) has been augmented with a CLM-Crop extension that simulates the development of three crop types: maize, soybean, and spring wheat. The CLM-Crop model is a complex system that relies on a suite of parametric inputs that govern plant growth under a given atmospheric forcing and available resources. CLM-Crop development used measurements of gross primary productivity (GPP) and net ecosystem exchange (NEE) from AmeriFlux sites to choose parameter values that optimize crop productivity in the model. In this paper, we calibrate these parameters for one crop type, soybean, in order to provide a faithful projection in terms of both plant development and net carbon exchange. Calibration is performed in a Bayesian framework by developing a scalable and adaptive scheme based on sequential Monte Carlo (SMC). The model showed significant improvement of crop productivity with the new calibrated parameters. We demonstrate that the calibrated parameters are applicable across alternative years and different sites.
The Horizontal Test Stand (HTS) SRF Cavity and Cryomodule 1 (CM1) of eight 9-cell, 1.3GHz SRF cavities are operating at Fermilab. For the cryogenic control system, how to hold liquid level constant in the cryostat by regulation of its Joule-Thompson JT-valve is very important after cryostat cool down to 2.0 K. The 72-cell cryostat liquid level response generally takes a long time delay after regulating its JT-valve; therefore, typical PID control loop should result in some cryostat parameter oscillations. This paper presents a type of PID parameter self-optimal and Time-Delay control method used to reduce cryogenic system parameters oscillation.
Using the G and K dwarfs from the Sloan Extension for Galactic Understanding and Exploration (SEGUE) survey, we determine the metallicity distributions of cool stars in the Milky Way disk system. This portion of the Sloan Digital Sky Survey (SDSS) contains spectra for approximately 41,500 G and 23,800 K dwarfs, a significantly larger sample, both numerically and spatially, than previous spectroscopic analyses. Comparison of these two spectral types, and their variation in metallicity with respect to Galactic position, provides important guidance for models of the formation and chemical evolution of the Milky Way's thick-disk component. SEGUE has a well-defined, quantitative target-selection algorithm, based on ugriz photometry and proper motions; this allows us to adjust our spectroscopic sample such that it accurately represents the underlying Milky Way populations.Combining atmospheric parameters, determined by an optimized version of the SEGUE Stellar Parameter Pipeline, with various isochrones, we calculate the distance to each star, accurate to {approx}12%. We then quantify the variation in metallicity with respect to spatial position from the Galactic center (R) and the plane of the Galaxy (|Z|). Our unbiased observations of G and K dwarfs provide valuable constraints for chemical and dynamical Galaxy evolution models, with particular utility for thin- and thick-disk formation theory. Although our uncertainties in the radial metallicity gradient are large, we are consistent with the results from Cheng et al., estimating a negative gradient below |Z| of 1 kpc that flattens above this height. Both spectral types also exhibit a consistent decrease in [Fe/H] with increasing |Z|, approximately -0.3 dex/kpc. Comparison with the sample of Lee et al., which distinguishes between the thin and thick disk using [{alpha}/Fe], suggests that this gradient reflects the transition in G and K dwarfs from a thin-disk dominated sample at small |Z| to a sample consisting primarily of thick-disk stars above |Z| of 1 kpc. We compare our distributions to those of two different models of the Galaxy: the population synthesis model TRILEGAL (Girardi et al. 2004) and that of Schoenrich & Binney which simulates chemical and dynamical evolution. Both models show little change in [Fe/H] with respect to |Z| and are unable to replicate the metallicity distributions we observe above |Z| of 0.5 kpc. This result is not surprising, as the existing chemical constraints on Galaxy models are limited to the solar neighborhood, which is thin-disk dominated.
Highlights: • Deformation processing map was developed for a 12Cr10Ni precipitation hardenable martensitic stainless steel and optimized hot working parameters were suggested to obtain defect free products. • The ‘stable’ domain of the processing maps were correlated to the dynamic recrystallization in the austenite phase and further confirmed by detailed microstructural investigations. • The DRx domain showed a refinement of the martensite packet size and of the prior transformation austenite grain size, essential to obtain the desired mechanical properties. - Abstract: Optimization of hot working parameters and corresponding microstructure control were explored in a 12Cr-10Ni precipitation hardenable martensitic stainless steel. From hot compression tests, 1073–1373 K (800°–1100 °C) and five (0.001–10 s{sup −1}) different strain rates, processing maps were developed, and various domains of microstructure evolution (in the austenite phase) were identified. The stable domain of the processing maps appeared to indicate dynamic recrystallization (DRx) in the austenite phase: as evident by the appearance of inflection point in the strain hardening rate versus flow stress plots. The suspected DRx domain was further confirmed by detailed microstructural investigations of the respective water-quenched specimens. The DRx domain showed a refinement of the martensite packet size and of the prior transformation austenite grain size. The later was shown with optical microstructure and reconstructed (modelled) microtexture data of the prior austenite grains. Additionally, the DRx domain showed a significant difference in activation energy as estimated from appropriate constitutive modelling.
This paper proposes a hybrid policy for a stochastic inventory system facing regular demand and surge demand. The combination of two different demand patterns can be observed in many areas, such as healthcare inventory and humanitarian supply chain management. The surge demand has a lower arrival rate but higher demand volume per arrival. The solution approach proposed in this paper incorporates the level crossing method and mixed integer programming technique to optimize the hybrid inventory policy with both regular orders and emergency orders. The level crossing method is applied to obtain the equilibrium distributions of inventory levels under a given policy. The model is further transformed into a mixed integer program to identify an optimal hybrid policy. A sensitivity analysis is conducted to investigate the impact of parameters on the optimal inventory policy and minimum cost. Numerical results clearly show the benefit of using the proposed hybrid inventory model. The model and solution approach could help healthcare providers or humanitarian logistics providers in managing their emergency supplies in responding to surge demands.
Purpose: To develop a Novel 4D MRI Technique that is feasible for realtime liver tumor tracking during radiotherapy. Methods: A volunteer underwent an abdominal 2D fast EPI coronal scan on a 3.0T MRI scanner (Siemens Inc., Germany). An optimal set of parameters was determined based on image quality and scan time. A total of 23 slices were scanned to cover the whole liver in the test scan. For each scan position, the 2D images were retrospectively sorted into multiple phases based on breathing signal extracted from the images. Consequently the 2D slices with same phase numbers were stacked to form one 3D image. Multiple phases of 3D images formed the 4D MRI sequence representing one breathing cycle. Results: The optimal set of scan parameters were: TR= 57ms, TE= 19ms, FOV read= 320mm and flip angle= 30°, which resulted in a total scan time of 14s for 200 frames (FMs) per slice and image resolution of (2.5mm,2.5mm,5.0mm) in three directions. Ten phases of 3D images were generated, each of which had 23 slices. Based on our test scan, only 100FMs were necessary for the phase sorting process which may lower the scan time to 7s/100FMs/slice. For example, only 5 slices/35s are necessary for a 4D MRI scan to cover liver tumor size ≤ 2cm leading to the possibility of tumor trajectory tracking every 35s during treatment. Conclusion: The novel 4D MRI technique we developed can reconstruct a 4D liver MRI sequence representing one breathing cycle (7s/ slice) without an external monitor. This technique can potentially be used for real-time liver tumor tracking during radiotherapy.
Purpose: Rigid 2D-3D registration is an alternative to 3D-3D registration for cases where largely bony anatomy can be used for patient positioning in external beam radiation therapy. In this article, the authors evaluated seven similarity measures for use in the intensity-based rigid 2D-3D registration using a variation in Skerl's similarity measure evaluation protocol. Methods: The seven similarity measures are partitioned intensity uniformity, normalized mutual information (NMI), normalized cross correlation (NCC), entropy of the difference image, pattern intensity (PI), gradient correlation (GC), and gradient difference (GD). In contrast to traditional evaluation methods that rely on visual inspection or registration outcomes, the similarity measure evaluation protocol probes the transform parameter space and computes a number of similarity measure properties, which is objective and optimization method independent. The variation in protocol offers an improved property in the quantification of the capture range. The authors used this protocol to investigate the effects of the downsampling ratio, the region of interest, and the method of the digitally reconstructed radiograph (DRR) calculation [i.e., the incremental ray-tracing method implemented on a central processing unit (CPU) or the 3D texture rendering method implemented on a graphics processing unit (GPU)] on the performance of the similarity measures. The studies were carried out using both the kilovoltage (kV) and the megavoltage (MV) images of an anthropomorphic cranial phantom and the MV images of a head-and-neck cancer patient. Results: Both the phantom and the patient studies showed the 2D-3D registration using the GPU-based DRR calculation yielded better robustness, while providing similar accuracy compared to the CPU-based calculation. The phantom study using kV imaging suggested that NCC has the best accuracy and robustness, but its slow function value change near the global maximum requires a stricter termination condition for an optimization method. The phantom study using MV imaging indicated that PI, GD, and GC have the best accuracy, while NCC and NMI have the best robustness. The clinical study using MV imaging showed that NCC and NMI have the best robustness. Conclusions: The authors evaluated the performance of seven similarity measures for use in 2D-3D image registration using the variation in Skerl's similarity measure evaluation protocol. The generalized methodology can be used to select the best similarity measures, determine the optimal or near optimal choice of parameter, and choose the appropriate registration strategy for the end user in his specific registration applications in medical imaging.
A stochastic approach based on generalized polynomial chaos (gPC) is used to quantify the error in large-eddy simulation (LES) of a spatially evolving mixing layer flow and its sensitivity to different simulation parameters, viz., the grid stretching in the streamwise and lateral directions and the subgrid-scale (SGS) Smagorinsky model constant (C{sub S}). The error is evaluated with respect to the results of a highly resolved LES and for different quantities of interest, namely, the mean streamwise velocity, the momentum thickness, and the shear stress. A typical feature of the considered spatially evolving flow is the progressive transition from a laminar regime, highly dependent on the inlet conditions, to a fully developed turbulent one. Therefore, the computational domain is divided in two different zones (inlet dependent and fully turbulent) and the gPC error analysis is carried out for these two zones separately. An optimization of the parameters is also carried out for both these zones. For all the considered quantities, the results point out that the error is mainly governed by the value of the C{sub S} constant. At the end of the inlet-dependent zone, a strong coupling between the normal stretching ratio and the C{sub S} value is observed. The error sensitivity to the parameter values is significantly larger in the inlet-dependent upstream region; however, low-error values can be obtained in this region for all the considered physical quantities by an ad hoc tuning of the parameters. Conversely, in the turbulent regime the error is globally lower and less sensitive to the parameter variations, but it is more difficult to find a set of parameter values leading to optimal results for all the analyzed physical quantities. A similar analysis is also carried out for the dynamic Smagorinsky model, by varying the grid stretching ratios. Comparing the databases generated with the different subgrid-scale models, it is possible to observe that the error cost function computed for the streamwise velocity and for the momentum thickness is not significantly sensitive to the used SGS closure. Conversely, the prediction of the shear stress is much more accurate when using a dynamic subgrid-scale model and the variance of the error is lower in magnitude.
Purpose: In this paper we show that optimization-based autofocus may be used to overcome the instabilities that have, until now, made high-resolution theoretically-exact tomographic reconstruction impractical. To our knowledge, this represents the first successful use of theoretically-exact reconstruction in helical micro computed tomography (micro-CT) imaging. We show that autofocus-corrected, theoretically-exact helical CT is a viable option for high-resolution micro-CT imaging at high cone-angles ({approx}50 deg.). The elevated cone-angle enables better utilization of the available X-ray flux and therefore shorter image acquisition time than conventional micro-CT systems. Methods: By using the theoretically-exact Katsevich 1PI inversion formula, we are not restricted to a low-cone-angle regime; we can in theory obtain artefact-free reconstructions from projection data acquired at arbitrary high cone-angles. However, this reconstruction method is sensitive to misalignments in the tomographic data, which result in geometric distortion and streaking artefacts. We use a parametric model to quantify the deviation between the actual acquisition trajectory and an ideal helix, and use an autofocus method to estimate the relevant parameters. We define optimal units for each parameter, and use these to ensure consistent alignment accuracy across different cone-angles and different magnification factors. The tomographic image is obtained from a set of virtual projections in which software correction for hardware misalignment has been applied. Results: We make significant modifications to the autofocus method that allow this method to be used in helical micro-CT reconstruction, and show that these developments enable theoretically-exact reconstruction from experimental data using the Katsevich 1PI (K1PI) inversion formula. We further demonstrate how autofocus-corrected, theoretically-exact helical CT reduces the image acquisition time by an order of magnitude compared to conventional circular scan micro-CT. Conclusions: Autofocus-corrected, theoretically-exact cone-beam reconstruction is a viable option for reducing acquisition time in high-resolution micro-CT imaging. It also opens up the possibility of efficiently imaging long objects.
In this work, the experimental conditions and parameters necessary to optimize the long-distance (≥ 60 Å) Double Electron-Electron Resonance (DEER) measurements of biomacromolecules labeled with Gd(III) tags are analyzed. The specific parameters discussed are the temperature, microwave band, the separation between the pumping and observation frequencies, pulse train repetition rate, pulse durations and pulse positioning in the electron paramagnetic resonance spectrum. It was found that: (i) in optimized DEER measurements, the observation pulses have to be applied at the maximum of the EPR spectrum; (ii) the optimal temperature range for Ka-band measurements is 14-17 K, while in W-band the optimal temperatures are between 6-9 K; (iii) W-band is preferable to Ka-band for DEER measurements. Recent achievements and the conditions necessary for short-distance measurements (<15 Å) are also briefly discussed.
Characterization of the AlMgB14-based coatings revealed their semi-crystalline nature; as a single phase, AlMgB 14 appears amorphous. Combining this material with TiB2 through comminution of very fine-scale powders (~100 nm), produces a bulk solid that exceeds the hardness of its respective constituent phases. Through physical vapor deposition processing, the resulting nanocomposite coating combines the wear resistance characteristic of hard materials (e.g. the AlMgB 14 ) with a regenerating lubricant. Within the top layers (10-20 nm) of the nanocomposite coating, the same TiB2 phase used to enhance the strength and provide ductility to the otherwise brittle AlMgB 14 material reacts with available oxygen to form boron oxide. As the atoms of TiB 2 continue to react, layers of boric acid begin to form at the surface. This affords an exceptionally low coefficient of friction (as low as 0.02) to the coating. Physical vapor deposition processing parameters were evaluated and optimized during the project to minimize the difficulties common to transitioning a laboratory-scale process or technology to a salable product. Coating process times and temperatures, process gas flows and ramp rates, and a number of other adjustable parameters were optimized based on the results of testing and coating characterization. The overriding goal of all of these efforts was a repeatable coating process that yields the benefits observed in the laboratory, independent of the intended product or market.