Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantum technologies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Magnetic force driven six degree-of-freedom active vibration isolation system using a phase compensated velocity sensor

A six-axis active vibration isolation system (AVIS) is developed using voice coil actuators. Point contact configuration is employed to have an easy assembly of eight voice coil actuators to an upper and a base plates. The velocity sensor, using an electromagnetic principle that is commonly used in the vibration control, is investigated since its phase lead characteristic causes an instability problem for a low frequency vibration. The performances of the AVIS are investigated in the frequency domain and finally validated by comparing with the passive isolation system using the atomic force microscope images.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Short pulse, high power microwave radiation source with a laser-induced sheet plasma mirror

We have demonstrated the short pulse, high power microwave radiation source using an ultraviolet laser-induced sheet plasma mirror in a gas-filled x-band rectangular waveguide from the conventional microwave sources and components. A laser-induced sheet plasma with an overdense plasma acts as a plasma mirror. The long pulse propagating in the gas-filled waveguide was sliced by the sheet plasma mirror at two different points along the waveguide. We observed about twice the power of the pulse by adding the two sliced microwave pulses produced by this scheme. A maximum peak power of 200 kW with a pulse duration of 10 ns (full width at half maximum) from the long microwave pulse source with a pulse duration of 0.8 mus was observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion energy distribution near a plasma meniscus for multielement focused ion beams

The axial ion energy spread near a plasma meniscus for multielement focused ion beams is investigated experimentally in atomic and molecular gaseous plasmas of krypton, argon, and hydrogen by tailoring the magnetic field in the region. In the case of magnetic end plugging, the ion energy spread reduces by approx50% near the meniscus as compared to the bulk plasma, thereby facilitating beam focusing. A quadrupole filter can be used to control the mean energy of the ions. Comparison with standard Maxwellian and Druyvesteyn distributions with the same mean energy indicates that the ion energy distribution in the meniscus is deficient in the population of low and high energy tail ions, resulting in a Gaussian-like profile with a spread of approx4 and approx5 eV for krypton and argon ions, respectively. By carefully tuning the wave power, plasma collisionality, and the magnetic field in the meniscus, the spread can be made lower than that of liquid metal ion sources, for extracting focused ion beams of other elements with adequate current density, for research and applications in nanosystems

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advanced photoelectric effect experiment beamline at Elettra: A surface science laboratory coupled with Synchrotron Radiation

We report the main characteristics of the advanced photoelectric effect experiments beamline, operational at Elettra storage ring, featuring a fully independent double branch scheme obtained by the use of chicane undulators and able to keep polarization control in both linear and circular mode. The paper describes the novel technical solutions adopted, namely, (a) the design of a quasiperiodic undulator resulting in optimized suppression of higher harmonics over a large photon energy range (10-100 eV), (b) the thermal stability of optics under high heat load via cryocoolers, and (c) the end station interconnected setup allowing full access to off-beam and on-beam facilities and, at the same time, the integration of users' specialized sample growth chambers or modules.

43 PARTICLE ACCELERATORS↗

Modulated transverse off-plane dust-lattice wave packets in hexagonal two-dimensional dusty plasma crystals

The propagation of nonlinear dust-lattice waves in a two-dimensional hexagonal crystal is investigated. Transverse (off-plane) dust grain oscillatory motion is considered in the form of a backward propagating wave packet whose linear and nonlinear characteristics are investigated. An evolution equation is obtained for the slowly varying amplitude of the first (fundamental) harmonic by making use of a two-dimensional lattice multiple scales technique. An analysis based on the continuum approximation (spatially extended excitations compared to the lattice spacing) shows that wave packets will be modulationally stable and that dark-type envelope solitons (density holes) may occur in the long wavelength region. Evidence is provided of modulational instability and of the occurrence of bright-type envelopes (pulses) at shorter wavelengths. The role of second neighbor interactions is also investigated and is shown to be rather weak in determining the modulational stability region. The effect of dissipation, assumed negligible in the algebra throughout the article, is briefly discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nanoposition sensors with superior linear response to position and unlimited travel ranges

With the advancement in nanotechnology, the ability of positioning/measuring at subnanometer scale has been one of the most critical issues for the nanofabrication industry and researchers using scanning probe microscopy. Commercial nanopositioners have achieved direct measurements at the scale of 0.01 nm with capacitive sensing metrology. However, the commercial sensors have small dynamic ranges (up to only a few hundred micrometers) and are relatively large in size (centimeters in the transverse directions to the motion), which is necessary for healthy signal detections but making it difficult to use on smaller devices. This limits applications in which large materials (on the scale of centimeters or greater) are handled with needs of subnanometer resolutions. What has been done in the past is to combine the fine and coarse translation stages with different dynamic ranges to simultaneously achieve long travel range and high spatial resolution. In this paper, we present a novel capacitive position sensing metrology with ultrawide dynamic range from subnanometer to literally any practically desired length for a translation stage. This sensor will greatly simplify the task and enhance the performance of direct metrology in a hybrid translational stage covering translation tasks from subnanometer to centimeters.

36 MATERIALS SCIENCE↗

Analysis and calibration of absorptive images of Bose-Einstein condensate at nonzero temperatures

We describe the method allowing quantitative interpretation of absorptive images of mixtures of Bose-Einstein condensate and thermal atoms which reduces possible systematic errors associated with evaluation of the contribution of each fraction and eliminates arbitrariness of most of the previous approaches. By using known temperature dependence of the BEC fraction, the analysis allows precise calibration of the fitting results. The developed method is verified in two different measurements and compares well with theoretical calculations and with measurements performed by another group.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Particle model analyses of N{sub 2}O dilution with He on electrical characteristics of radio-frequency discharges

The electrical characteristics (voltage, electric field, charged particle densities, dissipated power, particle energy, etc.) are analyzed in the case of low pressure (0.5 and 1 Torr) radio-frequency (rf) discharges in nitrous oxide (N{sub 2}O)/Helium (He) mixtures. An optimized and validated particle model has been used for these analyses in the case of gradual dilutions of N{sub 2}O with He buffer gas. A specific care is carried on the power density evolution and variation which show a complex behavior as a function of He proportion (up to 85%). These analyses are based on a microscopic approach enabling one to show the contribution of the different inelastic processes mainly between electrons and respectively N{sub 2}O and He gases. This approach enables also one to show the discharge region (the positive column or the plasma region) where the power is preferentially dissipated. The power density variation is found to be mainly proportional to the electron density variation. The latter is dependent on the different processes occurring between the charged particles [i.e., electrons, negative ions (O{sup -} and NO{sup -}), and positive ions (N{sub 2}O{sup +} and He{sup +})] and the neutral gas mixture (N{sub 2}O and He). Furthermore, the particle model shows the role of the electron-He collisions on the variation in the electron energy and distribution. This allows more particularly explaining the effects of N{sub 2}O dilution with He on the dissipated power variation in terms of creation and loss of electrons through collision processes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Filamentation in argon microwave plasma at atmospheric pressure

Filamentation in an argon plasma is studied using a microwave cavity at atmospheric pressure. We show that the size and gas temperature of the filaments increase with the power absorbed by the plasma. The appearance of an additional filament occurs at specific values of the absorbed power. Each new filament appears with a smaller diameter than that of its parent filament but the sum of the diameters of all filaments evolves linearly with the absorbed power. A secondary filament emerges from a set of microfilaments created by a perturbation of the electric field (a slight increase in the incident power above a threshold value). This perturbation occurs over a larger radius than that of the parent filament. By resorting to modeling, we found that the filamentation process involves either a decrease in the effective frequency for momentum-transfer collisions, i.e., a lower electron temperature, or an increase in the electron density. We could show that a small change in the relative positions occupied by two filaments in the microwave cavity requires a strong variation in the electron temperature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of electron temperature and density on ion-dust bremsstrahlung spectrum in dusty plasmas

The effects of electron temperature and density on the ion-dust grain bremsstrahlung process in dusty plasmas are studied. The ion-dust bremsstrahlung radiation cross section is obtained as a function of the dust charge, dust radius, Debye length, collision energy, radiation energy, electron density, and electron temperature by using the Born approximation. It is shown that the ion-dust bremsstrahlung radiation cross section decreases with an increase in the electron density in dusty plasmas. It is also shown that the electron temperature suppresses the bremsstrahlung radiation cross section. In addition, the effect of electron temperature on the ion-dust bremsstrahlung process is found to be more significant than the effect of electron density in dusty plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of rf power on electron density and temperature, neutral temperature, and T{sub e} fluctuations in an inductively coupled plasma

Atomic clocks that fly on global-navigation satellites such as global positioning system (GPS) and Galileo employ light from low-temperature, inductively coupled plasmas (ICPs) for atomic signal generation and detection (i.e., alkali/noble-gas rf-discharge lamps). In this application, the performance of the atomic clock and the capabilities of the navigation system depend sensitively on the stability of the ICP's optical emission. In order to better understand the mechanisms that might lead to instability in these rf-discharge lamps, and hence the satellite atomic clocks, we studied the optical emission from a Rb/Xe ICP as a function of the rf power driving the plasma. Surprisingly, we found that the electron density in the plasma was essentially independent of increases in rf power above its nominal value (i.e., 'rf-power gain') and that the electron temperature was only a slowly varying function of rf-power gain. The primary effect of rf power was to increase the temperature of the neutrals in the plasma, which was manifested by an increase in Rb vapor density. Interestingly, we also found evidence for electron temperature fluctuations (i.e., fluctuations in the plasma's high-energy electron content). The variance of these fluctuations scaled inversely with the plasma's mean electron temperature and was consistent with a simple model that assumed that the total electron density in the discharge was independent of rf power. Taken as a whole, our results indicate that the electrons in alkali/noble-gas ICPs are little affected by slight changes in rf power and that the primary effect of such changes is to heat the plasma's neutral species.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Three-dimensional model of magnetized capacitively coupled plasmas

A three-dimensional plasma model is used to understand the characteristics of magnetized capacitively coupled plasma discharges. The simulations consider plasmas generated using high frequency (13.5 MHz) and very high frequency (162 MHz) sources, electropositive (Ar) and electronegative (O{sub 2}) gases, and spatially uniform and nonuniform magnetic fields. Application of a magnetic field parallel to the electrodes is found to enhance the plasma density due to improved electron confinement and shift the plasma due to the ExB drift. The plasma is electrically symmetric at 162 MHz so it drifts in opposite directions adjacent to the two electrodes due to the ExB drift. On the other hand, the 13.5 MHz plasma is electrically asymmetric and it predominantly moves in one direction under the influence of the ExB drift. The ExB drift focuses the plasma into a smaller volume in regions with convex magnetic field lines. Conversely, the ExB drift spreads out the plasma in regions with concave magnetic field lines. In a magnetized O{sub 2} plasma, the overall plasma is found to move in one direction due to the ExB drift while the plasma interior moves in the opposite direction. This behavior is linked to the propensity of negative ions to reside in regions of peak plasma potential, which moves closer to the chamber center opposite to the ExB drift direction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Retarding potential and induction charge detectors in tandem for measuring the charge and mass of nanodroplets

The determination of the mass of a nanoparticle via time-of-flight typically requires a direct measurement of its charge. This can be done with a differential retarding potential analyzer and an induction charge detector operating in tandem. The spectrometer described in this article selects a particle with a specified retarding potential from a beam and directs it to an induction charge detector where both its velocity and charge are measured. The retarding potential, velocity, and charge also yield the particle's mass. The particle is analyzed without the need to collect it, and therefore can be employed in a subsequent experiment. The high charge sensitivity of the induction charge detector and the capability for working at low retarding potentials make the characterization of electrosprayed nanodroplets possible for the first time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The role of He in enhancing the intensity and lifetime of H and D emissions from laser-induced atmospheric-pressure plasma

A series of measurements have been performed on the time dependences of the intensities of helium, hydrogen, and deuterium emission lines from the corresponding laser-induced helium plasma at atmospheric pressure for two different He flow rates. The prolonged H{sub a}lpha and H{sub b}eta emissions along with their constant intensity ratio over a relatively extended period indicate the need to provide an alternative excitation mechanism other than the well-known thermal excitation process in a hot plasma. This additional excitation mechanism is also related to the metastable excited state of a He atom as indicated by the similar characteristics of the observed time dependence of the emission intensities. The enhanced intensity and lifetime of He emission at a high He flow rate was explained in terms of the collision-induced increase in the number of He atoms excited to above the 2 {sup 1}S{sub 0} metastable state, which was also responsible for the delayed excitation of H and D atoms via an energy transfer mechanism involving a Penning-like chemi-ionization process. Finally, the benefits of He-assisted delayed excitation of H and D atoms and the aforementioned enhanced intensity and lifetime at a high He flow rate were demonstrated by the achievement of clearly resolved H{sub a}lpha and D{sub a}lpha emission lines.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast discharge in a plasma gun with hemispherical insulator

A method of creation of hot dense plasma is proposed. It is based on cumulation of a shockwave, which originates on a hemispherical surface of insulator of plasma gun. The results of first experiments are presented. The shock wave is driven by fast electrical discharge (dI/dt>10{sup 12} A/s). The inductive storage with semiconductor opening switch is used as a current driver. Time resolved pin-hole images and vacuum ultraviolet (vuv) spectra are studied. Shockwaves from hemispherical insulator with 4 mm radius create plasma with a form of column about 1 mm diameter and 3-4 mm length. vuv spectra contain the lines of Ar ions that corresponds to the electron temperature about 20 eV. Possible practical application is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sizing and burn time measurements of micron-sized metal powders

Detailed ignition and combustion mechanisms are needed to develop optimized propellant and energetic formulations using micron-sized metal powders, such as aluminum. Combustion researchers have traditionally used relatively coarse metal particles to characterize the burn time dependence on particle size. However, measurements of burn times for particles below 10 {mu}m in diameter are still needed for aluminum powders and other metal fuels. The apparatus described here sizes the particles just before the ignition event, providing a direct correlation between individual particle size and its burn time. Two lasers were utilized: a 785 nm laser diode for sizing the particles and a 125 W CO{sub 2} laser for particle ignition. The particles crossed the 785 nm laser beam just before crossing the CO{sub 2} laser beam. The particle size was determined from the amplitude of the scattered 785 nm light pulse. The burn time was determined from the duration of the visible light emission produced from the ignited particle. The in situ measured particle size distributions compared well with the size distributions measured for the same powders by a commercial instrument using low angle laser light scattering. Our measurements with two nominally spherical aluminum powders, suggest that the burn times increase from 0.5 to {approx}2.5 ms as the particle diameters increase from 3 to 8 {mu}m.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Digital ratemeter with fast response

Digital ratemeter that operates according to a self-adjusting algorithm, which at low rates automatically switches from a preset count to the preset time method, is proposed. It combines the good properties of both methods concerning the accuracy of the measured average counting rate and the response time to sudden changes of rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative displacement measurement of a nanotube cantilever with nanometer accuracy using epifluorescence microscopy

A method to measure the deflection of a nanotube cantilever with nanometer accuracy in an air or liquid environment is presented. We attached fluorescent dyes at the end of a nanotube to detect its deflection. The nanotube cantilever was fabricated with a multiwalled carbon nanotube that is attached to the end of an electrochemically etched tungsten tip, and it was imaged in an epifluorescence microscope system. The fluorescence intensity distribution of the fluorescent particles at the end of the nanotube was approximated with a Gaussian and fitted by least-squares method. Finally, we were able to measure the displacement of the nanotube cantilever during electrostatic actuation with positional accuracy of a few nanometers. This technique can be applied to a manipulator or a force transducer on related a few piconewton forces.

42 ENGINEERING↗