Search NASA⌕ Search

SEARCH · Search NASA

Results for “read performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,585 records · Page 88

Global Radiological Source Sorting, Tracking, and Monitoring Project: Phase I Final Report

As a proof of concept tested in an operational context, the Global Radiological Source Sorting, Tracking, and Monitoring (GRadSSTraM) Project successfully demonstrated that radio frequency identification (RFID) and Web 2.0* technologies can be deployed to track controlled shipments between the United States and the European Union. Between November 2009 and May 2010, a total of 19 shipments were successfully shipped from Oak Ridge National Laboratory (ORNL) by the U.S. Postal Service (USPS) and tracked to their delivery at England's National Physical Laboratory (NPL) by the United Kingdom Royal Mail. However, the project can only be viewed as a qualified success as notable shortcomings were observed. Although the origin and terminus of all RFID-enabled shipments were recorded and no shipments were lost, not all the waypoints between ORNL and NPL were incorporated into the pilot. Given limited resources, the project team was able to install RFID listeners/actuators at three waypoints between the two endpoints. Although it is likely that all shipments followed the same route between ORNL and NPL, it cannot be determined beyond question that all 19 shipments were routed on identical itineraries past the same three waypoints. The pilot also raises the distinct possibility that unattended RFID tracking alone, without positive confirmation that a tagged item has been properly recorded by an RFID reader, does not meet a rigorous standard for shipping controlled items. Indeed, the proof of concept test strongly suggests that a multifaceted approach to tracking may be called for, including tracking methods that are capable of reading and accepting multiple inputs for individual items [e.g., carrier-provided tracking numbers, Universal Product Codes (UPCs), and RFID tags]. For controlled items, another apparent requirement is a confirmation feature, human or otherwise, which can certify that an item's RFID tag, UPC, or tracking number has been recorded.

42 ENGINEERING↗

Comparison of MPEG-1 digital videotape with digitized sVHS videotape for quantitative echocardiographic measurements

Digital format is rapidly emerging as a preferred method for displaying and retrieving echocardiographic studies. The qualitative diagnostic accuracy of Moving Pictures Experts Group (MPEG-1) compressed digital echocardiographic studies has been previously reported. The goals of the present study were to compare quantitative measurements derived from MPEG-1 recordings with the super-VHS (sVHS) videotape clinical standard. Six reviewers performed blinded measurements from still-frame images selected from 20 echocardiographic studies that were simultaneously acquired in sVHS and MPEG-1 formats. Measurements were obtainable in 1401 (95%) of 1486 MPEG-1 variables compared with 1356 (91%) of 1486 sVHS variables (P <.001). Excellent agreement existed between MPEG-1 and sVHS 2-dimensional linear measurements (r = 0.97; MPEG-1 = 0.95[sVHS] + 1.1 mm; P <.001; Delta = 9% +/- 10%), 2-dimensional area measurements (r = 0.89), color jet areas (r = 0.87, p <.001), and Doppler velocities (r = 0.92, p <.001). Interobserver variability was similar for both sVHS and MPEG-1 readings. Our results indicate that quantitative off-line measurements from MPEG-1 digitized echocardiographic studies are feasible and comparable to those obtained from sVHS.

NASA Discipline Cardiopulmonary↗

CRUQS: A Miniature Fine Sun Sensor for Nanosatellites

A new miniature fine Sun sensor has been developed that uses a quadrant photodiode and housing to determine the Sun vector. Its size, mass, and power make it especially suited to small satellite applications, especially nanosatellites. Its accuracy is on the order of one arcminute, and it will enable new science in the area of nanosatellites. The motivation for this innovation was the need for high-performance Sun sensors in the nanosatellite category. The design idea comes out of the LISS (Lockheed Intermediate Sun Sensor) used by the sounding rocket program on their solar pointing ACS (Attitude Control System). This system uses photodiodes and a wall between them. The shadow cast by the Sun is used to determine the Sun angle. The new sensor takes this concept and miniaturizes it. A cruciform shaped housing and a surface-mount quadrant photodiode package allow for a two-axis fine Sun sensor to be packaged into a space approx.1.25xl x0.25 in. (approx.3.2x2.5x0.6 cm). The circuitry to read the photodiodes is a simple trans-impedance operational amplifier. This is much less complex than current small Sun sensors for nanosatellites that rely on photo-arrays and processing of images to determine the Sun center. The simplicity of the circuit allows for a low power draw as well. The sensor consists of housing with a cruciform machined in it. The cruciform walls are 0.5-mm thick and the center of the cruciform is situated over the center of the quadrant photodiode sensor. This allows for shadows to be cast on each of the four photodiodes based on the angle of the Sun. A simple operational amplifier circuit is used to read the output of the photodiodes as a voltage. The voltage output of each photodiode is summed based on rows and columns, and then the values of both rows or both columns are differenced and divided by the sum of the voltages for all four photodiodes. The value of both difference over sums for the rows and columns is compared to a table or a polynomial fit (depending on processor power and accuracy requirements) to determine the angle of the Sun in the sensor frame.

Heatwole, Scott↗

Q2 Report for FY25 Theory and Simulation Performance Target: Development of an integrated modeling framework for fusion reactor design and assessment

This report describes the work and activities carried out towards the completion of each of the following milestones in FY25 Q2: 1. Demonstrate workflow for generating self-consistent CESOL plasma profiles + first wall and divertor loading prediction and generate the CAT plasma and neutron loading needed for further engineering analysis: $\circ$ Run CESOL with BOUT++/Hermes-3 and immersed boundary condition to directly map to wall: • Run BOUT++/Hermes-3 through the IPS workflow to find radial particle and energy diffusivities to match either the Eich or the physics-based scaling of the SOL heat flux width, and • Expand source of first wall heat flux to include charged particles, neutrals, and radiation from the core+edge. 2. Generate medium fidelity parametrized CAD: $\circ$ Develop the TRACER tool to read an existing CAD, regenerate the geometry based on vertex location and connectivity information, define vertex translation and parameters needed for scaling the CAD, and $\circ$ Utilize the FreeGS code to determine CAT PF coil placement, including minimizing the number of coils, coil current, and electromechanical stresses. 3. Utilize plasma loading for engineering analysis: $\circ$ Couple the plasma loading to input for OpenFOAM and demonstrate initial test of thermal analysis of CAT first wall loading with typical DCLL blanket component cooling boundary conditions. 4. Demonstrate nuclear analysis: $\circ$ Apply initial analysis of tritium transport in DCLL blanket by evaluating spatially resolved tritium generation rates, tritium diffusion and convection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Small, Inexpensive Combined NOx Sensor and O2 Sensor

It has been successfully demonstrated in this program that a zirconia multilayer structure with rhodium-based porous electrodes performs well as an amperometric NOx sensor. The sensitivity of the sensor bodies operating at 650 to 700 C is large, with demonstrated current outputs of 14 mA at 500 ppm NOx from sensors with 30 layers. The sensor bodies are small (4.5 x 4.2 x 3.1 mm), rugged, and inexpensive. It is projected the sensor bodies will cost $5 - $10 in production. This program has built on another successful development program for an oxygen sensor based on the same principles and sponsored by DOE. This oxygen sensor is not sensitive to NOx. A significant technical hurdle has been identified and solved. It was found that the 100% Rh electrodes oxidize rapidly at the preferred operating temperatures of 650 - 700 C, and this oxidation is accompanied by a volume change which delaminates the sensors. The problem was solved by using alloys of Rh and Pt. It was found that a 10%/90% Rh/Pt alloy dropped the oxidation rate of the electrodes by orders of magnitude without degrading the NOx sensitivity of the sensors, allowing long-term stable operation at the preferred operating temperatures. Degradation in the sensor output caused by temperature cycling was identified as a change in resistance at the junction between the sensor body and the external leads attached to the sensor body. The degradation was eliminated by providing strong mechanical anchors for the wire and processing the junctions to obtain good electrical bonds. The NOx sensors also detect oxygen and therefore the fully-packaged sensor needs to be enclosed with an oxygen sensor in a small, heated zirconia chamber exposed to test gas through a diffusion plug which limits the flow of gas from the outside. Oxygen is pumped from the interior of the chamber to lower the oxygen content and the combination of measurements from the NOx and oxygen sensors yields the NOx content of the gas. Two types of electronic control units were designed and built. One control unit provides independent constant voltages to the NOx and oxygen sensors and reads the current from them (that is, detects the amount of test gas present). The second controller holds the fully-assembled sensor at the desired operating temperature and controllably pumps excess oxygen from the test chamber. While the development of the sensor body was a complete success, the development of the packaging was only partially successful. All of the basic principles were demonstrated, but the packaging was too complex to optimize the operation within the resources of the program. Thus, no fully-assembled sensors were sent to outside labs for testing of cross-sensitivities, response times, etc. Near the end of the program, Sensata Technologies of Attleboro, MA tested the sensor bodies and confirmed the CeramPhysics measurements as indicated in the following attached letter. Sensata was in the process of designing their own packaging for the sensor and performing cross-sensitivity tests when they stopped all sensor development work due to the automotive industry downturn. Recently Ceramatec Inc. of Salt Lake City has expressed an interest in testing the sensor, and other licensing opportunities are being pursued.

47 OTHER INSTRUMENTATION↗

A bespoke model of Arctic river basins based on hillslope delineation: Model Archive

This dataset is a model archive of the paper A bespoke model of Arctic river basins based on hillslope delineation (in prep), which introduces a watershed decomposition and parameterization method for large scale permafrost hydrology simulation. With this dataset, this study aims to address the research question: whether a computationally efficient hillslope-based modeling framework can reliably simulate discharge at Arctic river-basin scales. This dataset contains model input and output data for five modeling scenarios at a study site located in the Sagavanirktok River basin. The five modeling scenarios include three modeling cases under temperate conditions using full 3D, decomposed 3D, and decomposed 2D modeling strategies; and two modeling cases under actual Arctic conditions with permafrost using full 3D and decomposed 2D modeling strategies. Simulations were performed using the Advanced Terrestrial Simulator (ATS, v1.6 for three temperate scenarios and v1.5 for two Arctic scenarios), a physics-rich integrated surface–subsurface hydrologic model with cryo-hydrology features. For the three temperate models, simulations were conducted for the period of 10/01/1993 - 09/30/2002; and for the two Arctic models, simulations were conducted for the period of 01/01/1994 - 12/31/2002. To facilitate reproducibility of simulations, all datasets are organized hierarchically. The dataset contains: (1) Mesh files (.exo) for full 3D model, decomposed 3D models, and decomposed 2D models, located in huc/190604020802_gauge15906000/mesh/. Mesh files can be visualized through Paraview or read by Python. (2) Climate forcings (.h5) for full 3D model and decomposed 3D/2D models are located in huc/190604020802_gauge15906000/daymet_onePiece/, and huc/190604020802_gauge15906000/vp_pr_revised_daymet_1980_2006_with_wind/ separately. Accessible by Python. (3) Raw measured gage discharge (.csv) from USGS, located in huc/190604020802_gauge15906000/gaged_basin15906000_discharge_usgs/. Accessible by Python. (4) Delineated subdomain raster (.tif) and shape files (.shp), and the final parameterized results (.npy) for decomposed models, located in huc/190604020802_gauge15906000/data_preprocessed-meshing. Accessible by Python. (5) Temperate models are located in nonpermaf_huc190604020802_gauge15906000/, which includes three cases: decomposed 2D models (inside model_0*-hillslope_*), decomposed 3D models (inside model_1*-subcatchment_*), and full 3D model (inside model_2*-onepiece_*). Two step spin-up results (checkpoint_final.h5) are located in model_*1-*_spinup_steadystate and model_*2-*_spinup_cycle, separately, which are used to initialize real transient models. The input files (.xml) and output results (.dat) of the real transient models are located in model_*3-*_transient/. Especially, for two example hillslope models (ID=-11 and 11), additional h5py files are included in model_03-hillslope_transient/hillslope-11/, model_03-hillslope_transient/hillslope11, model_13-subcatchment_transient/subcatchment-11/, model_13-subcatchment_transient/subcatchment/11, respectively, which are used to plot the saturation figure (Figure 5) in the manuscript. Accessible by Python. (6) Arctic models are located in huc190604020802_gauge15906000/, which includes two cases: decomposed 2D models (inside model_04-hillslope_transient), and full 3D model (inside model_05-onepiece_transient_mannp1_ra). Three step spin-up results (checkpoint_final.h5) are located in model_01-column_freezeup/, model_02-column_spinup/, model_03-hillslope_spinup/, respectively, which are used to initialize real 2D transient hillslope models. The input files (.xml) and output results (.dat) of transient 2D hillslope models are located in model_04-hillslope_transient/. The input files (.xml) and output results (.dat) of the full 3D transient model is located in model_05-onepiece_transient_mannp1_ra/. The full 3D transient model is initialized by model_02-column_spinup/. Accessible by Python. (7) The MOSART routed discharge results (.csv) under Arctic conditions is located in huc190604020802_gauge15906000/MOSART/. Accessible by Python. (8) All Python codes (.py) used to parameterize full 3D model to decomposed 2D models are located in script/. These codes fit with watershed workflow (a watershed delineation tool) v1.4 under the branch gaob/v1.4 from https://github.com/gaobhub/watershed-workflow.git.

EARTH SCIENCE > CRYOSPHERE↗

Synchronous and Cogged Fan Belt Performance Assessment

The GSA Regional GPG Team commissioned the National Renewable Energy Laboratory (NREL) to perform monitoring of cogged V-belts and synchronous belts on both a constant volume and a variable air volume fan at the Byron G. Rodgers Federal Building and U.S. Courthouse in Denver, Colorado. These motor/fan combinations were tested with their original, standard V-belts (appropriately tensioned by an operation and maintenance professional) to obtain a baseline for standard operation. They were then switched to the cogged V-belts, and finally to synchronous belts. The power consumption by the motor was normalized for both fan speed and air density changes. This was necessary to ensure that the power readings were not influenced by a change in rotational fan speed or by the power required to push denser air. Finally, energy savings and operation and maintenance savings were compiled into an economic life-cycle cost analysis of the different belt options.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

NANO.PTML model for read-across prediction of nanosystems in neurosciences. computational model and experimental case of study

Abstract Neurodegenerative diseases involve progressive neuronal death. Traditional treatments often struggle due to solubility, bioavailability, and crossing the Blood-Brain Barrier (BBB). Nanoparticles (NPs) in biomedical field are garnering growing attention as neurodegenerative disease drugs (NDDs) carrier to the central nervous system. Here, we introduced computational and experimental analysis. In the computational study, a specific IFPTML technique was used, which combined Information Fusion (IF) + Perturbation Theory (PT) + Machine Learning (ML) to select the most promising Nanoparticle Neuronal Disease Drug Delivery (N2D3) systems. For the application of IFPTML model in the nanoscience, NANO.PTML is used. IF-process was carried out between 4403 NDDs assays and 260 cytotoxicity NP assays conducting a dataset of 500,000 cases. The optimal IFPTML was the Decision Tree (DT) algorithm which shown satisfactory performance with specificity values of 96.4% and 96.2%, and sensitivity values of 79.3% and 75.7% in the training (375k/75%) and validation (125k/25%) set. Moreover, the DT model obtained Area Under Receiver Operating Characteristic (AUROC) scores of 0.97 and 0.96 in the training and validation series, highlighting its effectiveness in classification tasks. In the experimental part, two samples of NPs (Fe 3 O 4 _A and Fe 3 O 4 _B) were synthesized by thermal decomposition of an iron(III) oleate (FeOl) precursor and structurally characterized by different methods. Additionally, in order to make the as-synthesized hydrophobic NPs (Fe 3 O 4 _A and Fe 3 O 4 _B) soluble in water the amphiphilic CTAB (Cetyl Trimethyl Ammonium Bromide) molecule was employed. Therefore, to conduct a study with a wider range of NP system variants, an experimental illustrative simulation experiment was performed using the IFPTML-DT model. For this, a set of 500,000 prediction dataset was created. The outcome of this experiment highlighted certain NANO.PTML systems as promising candidates for further investigation. The NANO.PTML approach holds potential to accelerate experimental investigations and offer initial insights into various NP and NDDs compounds, serving as an efficient alternative to time-consuming trial-and-error procedures.

60 APPLIED LIFE SCIENCES↗

Measurement of the production and elliptic flow of (anti)nuclei in Xe-Xe collisions at √sNN = 5.44 TeV

Measurements of (anti)deuteron and (anti) 3He production in the rapidity range |𝑦|<0.5 as a function of the transverse momentum and event multiplicity in Xe-Xe collisions at a center-of-mass energy per nucleon-nucleon pair of √𝑠𝑁⁢𝑁=5.44 TeV are presented. The coalescence parameters 𝐵2 and 𝐵3 are measured as a function of the transverse momentum per nucleon. The ratios between (anti)deuteron and (anti) 3He yields and those of (anti)protons and pions are reported as a function of the mean charged-particle multiplicity density and compared with two implementations of the statistical hadronization model and with coalescence predictions. The elliptic flow of (anti)deuterons is measured for the first time in Xe-Xe collisions and shows features similar to those already observed in Pb-Pb collisions, i.e., the mass ordering at low transverse momentum and the meson-baryon grouping at intermediate transverse momentum. The production of nuclei is particularly sensitive to the chemical freeze-out temperature of the system created in the collision, which is extracted from a grand-canonical-ensemble-based thermal fit, performed for the first time including light nuclei along with light-flavor hadrons in Xe-Xe collisions. The extracted chemical freeze-out temperature 𝑇chem=(154.2±1.1) MeV in Xe-Xe collisions is similar to that observed in Pb-Pb collisions and close to the crossover temperature predicted by lattice quantum chromodynamics calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Small, Inexpensive Combined NOx and O2 Sensor

It has been successfully demonstrated in this program that a zirconia multilayer structure with rhodium-based porous electrodes performs well as an amperometric NO{sub x} sensor. The sensitivity of the sensor bodies operating at 650 to 700 C is large, with demonstrated current outputs of 14 mA at 500 ppm NO{sub x} from sensors with 30 layers. The sensor bodies are small (4.5 x 4.2 x 3.1 mm), rugged, and inexpensive. It is projected the sensor bodies will cost $5-$10 in production. This program has built on another successful development program for an oxygen sensor based on the same principles and sponsored by DOE. This oxygen sensor is not sensitive to NO{sub x}. A significant technical hurdle has been identified and solved. It was found that the 100% Rh electrodes oxidize rapidly at the preferred operating temperatures of 650-700 C, and this oxidation is accompanied by a volume change which delaminates the sensors. The problem was solved by using alloys of Rh and Pt. It was found that a 10%/90% Rh/Pt alloy dropped the oxidation rate of the electrodes by orders of magnitude without degrading the NO{sub x} sensitivity of the sensors, allowing long-term stable operation at the preferred operating temperatures. Degradation in the sensor output caused by temperature cycling was identified as a change in resistance at the junction between the sensor body and the external leads attached to the sensor body. The degradation was eliminated by providing strong mechanical anchors for the wire and processing the junctions to obtain good electrical bonds. The NO{sub x} sensors also detect oxygen and therefore the fully-packaged sensor needs to be enclosed with an oxygen sensor in a small, heated zirconia chamber exposed to test gas through a diffusion plug which limits the flow of gas from the outside. Oxygen is pumped from the interior of the chamber to lower the oxygen content and the combination of measurements from the NO{sub x} and oxygen sensors yields the NO{sub x} content of the gas. Two types of electronic control units were designed and built. One control unit provides independent constant voltages to the NOx and oxygen sensors and reads the current from them (that is, detects the amount of test gas present). The second controller holds the fully-assembled sensor at the desired operating temperature and controllably pumps excess oxygen from the test chamber. While the development of the sensor body was a complete success, the development of the packaging was only partially successful. All of the basic principles were demonstrated, but the packaging was too complex to optimize the operation within the resources of the program. Thus, no fully-assembled sensors were sent to outside labs for testing of cross-sensitivities, response times, etc. Near the end of the program, Sensata Technologies of Attleboro, MA tested the sensor bodies and confirmed the CeramPhysics measurements as indicated in the following attached letter. Sensata was in the process of designing their own packaging for the sensor and performing cross-sensitivity tests when they stopped all sensor development work due to the automotive industry downturn. Recently Ceramatec Inc. of Salt Lake City has expressed an interest in testing the sensor, and other licensing opportunities are being pursued.

47 OTHER INSTRUMENTATION↗

Engineering CAM Photosynthetic Machinery into Bioenergy Crops for Biofuels Production in Marginal Environments

CAM provides an excellent opportunity to engineer enhanced photosynthetic performance and water-use efficiency (WUE) into bioenergy crops. Our vision was to understand the enzymatic and regulatory pathways required for CAM in order to engineer CAM photosynthetic machinery into Arabidopsis and Populus. Major advances were made in understanding the molecular “parts list” necessary for engineering CAM through the sequencing the genomes and transcriptomes of several model and agronomically important CAM species including Agave, Ananas, Clusia, Kalanchoe, Mesembryanthemum, and Opuntia. Comparison of diel co-expression network analyses in Agave, Ananas, and Kalanchoe with expression patterns in C 3 photosynthesis species revealed the rescheduling of gene expression associated with stomatal opening and closing and led to the identification of many candidate CAM-related genes for further functional testing. Both RNAi-mediated gene silencing and CRISPR/Cas genome editing for gene knockout were used to investigate over 70 CAM-related enzymes, regulatory kinases/phosphatases, and transporters and 25 transcription factors implicated in playing key regulatory roles in CAM. Knockdown of key C 4 cycle enzymes within the carboxylation and decarboxylation modules of CAM not only perturbed CAM itself, but also altered the expression of core circadian clock components demonstrating that loss of CAM function also perturbs the central circadian clock and alters the regulatory patterns of key guard cell signaling genes that are linked with the characteristic inverse pattern of stomatal opening and closing during CAM. An advanced system for joining D.AN fragments from a universal library was developed that automatically maintains open reading frames (ORFs) and does not require linkers, adaptors, regions of sequence homology, amplification (or mutation for domestication) of fragments to function systems for the construction of gene circuits. Alternatively, Gibson assembly was used to create gene circuits consisting of up to 15 unique gene expression cassettes expressing either the core C 4 cycle of CAM comprising carboxylation or decarboxylation modules or both modules together. The expression of each gene cassette was driven by a drought-stress inducible 5’ regulatory region or promoter (and cognate 3’ terminator region) from A. thaliana so that CAM gene expression would be enhanced under conditions of water-deficit stress. These gene circuits were introduced into the C 3 photosynthesis model species A. thaliana. Expression of the nocturnal carboxylation module resulted in increased biomass and seed yield arising from net CO 2 fixation at night and malate accumulation typical of a CAM plant along with daytime CO 2 fixation typical of a C 3 photosynthesis plant. To create a leaf anatomy suited for the optimal performance of CAM in a C 3 photosynthesis plant, increased tissue succulence was engineered in A. thaliana (and Nicotiana sylvestris), which also improved biomass and seed yield and drought attenuation and improved salinity tolerance. The basic CAM Biodesign principles described in this report can be extended to increase the productivity and WUE of food and bioenergy crops and are expected to have broad applicability and ensure sustainable biofuel feedstock production in the face of the global climate crisis.

59 BASIC BIOLOGICAL SCIENCES↗

Implanted Dosimeters Identify Radiation Overdoses During IMRT for Prostate Cancer

Purpose: Image-guided dose-escalated radiotherapy is the standard of care for the treatment of prostate cancer. Although many published methods are available that account for prostate motion during delivery, evidence demonstrating that the planned dose is actually delivered on a daily basis is lacking. We report our initial clinical experience using implantable dosimeters to quantify and adjust the dose received during intensity-modulated radiotherapy (IMRT). Methods and Materials: A total of 20 patients undergoing IMRT with cone-beam computed tomography (CT) image guidance for prostate cancer had the dose verification system with radiopaque metal-oxide-semiconductor field effect transistor dosimeters implanted before treatment planning. All patients underwent planning with CT simulation in the supine position with custom immobilization, and the implanted dosimeters were located in the IMRT plans. The predicted dose for each dosimeter was defined and compared with the wireless readings before and after each treatment session. Investigations by physicians and medical physicists were initiated for two or more discrepancies >6% for any five consecutive fractions or for any discrepancy {>=}10%. Results: Using implanted in vivo dosimeters, dose measurements consistently >6% greater than the predicted values were observed during treatment for 3 of 20 prostate cancer patients who received IMRT with daily image guidance. A review of the daily cone-beam CT images revealed acceptable alignment of the prostate target volumes and implanted dosimeters but identified significant anatomic changes within the treated region. Repeat CT simulation and RT planning was performed, with resolution of the dose discrepancies in all 3 cases with the adoption of a new IMRT plan. Conclusions: Our report illustrates the potential effect of implanted in vivo dosimetry for prostate IMRT and emphasizes the importance of careful planning and delivery with attention to systematic shifts or anatomic changes that could alter the dose distributions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Peak2Patch: High-Fidelity Functional Group Identification through Attention-Based Fusion of Infrared and Mass Spectra

Identifying molecular structure based on spectroscopic readings is a key task in a variety of chemical and biological applications. Common spectroscopy techniques, such as Infrared (IR) Spectroscopy and Mass Spectrometry (MS), provide detailed information on the structure of molecular compounds but nonetheless require expert-level knowledge to decode. Machine learning has emerged as a potential solution for automating structure prediction from chemical spectra; however, current approaches generally focus on single sensor modalities, neglecting to leverage the complementary information contained within differing spectra. In this paper, we introduce Peak2Patch, a novel approach to fusion-enhanced prediction of functional groups from IR and mass spectra. First, we perform a detailed comparison of backbone networks for encoding both sparse mass spectra and dense IR spectra and demonstrate the superior performance of transformer neural networks over current state-of-the-art convolutional neural networks. Second, we evaluate three broad categories of fusion: early (raw feature), middle (deep feature), and late (decision) fusion, demonstrating the potential of a deep feature fusion-based approach. Lastly, we present Peak2Patch, our attention-based fusion scheme, which leverages cross-attention to mix features between encoded tokens of the two modalities. We validate our approach on a publicly available multimodal spectroscopic data set of 790k simulated molecules, demonstrating a large improvement in functional group prediction over both the previous state-of-the-art and our own strong single-modal baselines.

Jacobson, Philip [Sandia National Laboratories (SN↗

DNABERT-S: pioneering species differentiation with species-aware DNA embeddings

SUMMARY: We introduce DNABERT-S, a tailored genome model that develops species-aware embeddings to naturally cluster and segregate DNA sequences of different species in the embedding space. Differentiating species from genomic sequences (i.e. DNA and RNA) is vital yet challenging, since many real-world species remain uncharacterized, lacking known genomes for reference. Embedding-based methods are therefore used to differentiate species in an unsupervised manner. DNABERT-S builds upon a pre-trained genome foundation model named DNABERT-2. To encourage effective embeddings to error-prone long-read DNA sequences, we introduce Manifold Instance Mixup (MI-Mix), a contrastive objective that mixes the hidden representations of DNA sequences at randomly selected layers and trains the model to recognize and differentiate these mixed proportions at the output layer. We further enhance it with the proposed Curriculum Contrastive Learning (C2LR) strategy. Empirical results on 28 diverse datasets show DNABERT-S's effectiveness, especially in realistic label-scarce scenarios. For example, it identifies twice more species from a mixture of unlabeled genomic sequences, doubles the Adjusted Rand Index (ARI) in species clustering, and outperforms the top baseline's performance in 10-shot species classification with just a 2-shot training. AVAILABILITY AND IMPLEMENTATION: Model, codes, and data are publically available at https://github.com/MAGICS-LAB/DNABERT_S.

Zhou, Zhihan↗

SU-E-T-638: Evaluation and Comparison of Landauer Microstar (OSLD) Readers

Purpose: To evaluate and compare characteristic performance of a new Landauer nanodot Reader with the previous model. Methods: In order to calibrate and test the reader, a set of nanodots were irradiated using a Varian Truebeam Linac. Solid water slabs and bolus were used in the process of irradiation. Calibration sets of nanodots were irradiated for radiation dose ranges: 0 to 10 and 20 to 1000 cGy, using 6MV photons. Additionally, three sets of nanodots were each irradiated using 6MV, 10MV and 15MV beams. For each beam energy, and selected dose in the range of 3 to 1000 cGy, a pair of nanodots was irradiated and three readings were obtained with both readers. Results: The analysis shows that for 3 photon beam energies and selected ranges of dose, the calculated absorbed dose agrees well with the expected value. The results illustrate that the new Microstar II reader is a highly consistent system and that the repeated readings provide results with a reasonably small standard deviation. For all practical purposes, the response of system is linear for all radiation beam energies. Conclusion: The Microstar II nanodot reader is consistent, accurate, and reliable. The new hardware design and corresponding software contain several advantages over the previous model. The automatic repeat reading mechanism, that helps improve reproducibility and reduce processing time, and the smaller unit size that renders ease of transport, are two of such features. Present study shows that for high dose ranges a polynomial calibration equation provides more consistent results. A 3rd order polynomial calibration curve was used to analyze the readings of dosimeters exposed to high dose range radiation. It was observed that the results show less error compared to those calculated by using linear calibration curves, as provided by Landauer system software for all dose ranges.

60 APPLIED LIFE SCIENCES↗

Monitoring physical and chemical parameters of Delaware Bay waters with an ERTS-1 data collection platform

The author has identified the following significant results. Evaluation of the probe performances during the initial phase indicates that the dissolved oxygen sensor available as part of the package is not sufficiently reliable for long term operation. The turbidity probe requires frequent visits to the site to maintain it in proper operating condition. The cost of these visits would have to be weighed against the information obtained. The conductivity/salinity, temperature, pH, and depth indicators have worked extremely well over the course of the study. Monthly cleanings would maintain all these probes in top operating condition. Currently the accuracy of each measurement returned via satellite is being compared to the accuracy of the probe reading and water samples analyzed in the laboratory.

Klemas, V.↗

OF MICROBES AND MEN: A SPECIAL REPORT IN THE JOURNAL FOR MINORITY MEDICAL STUDENTS

In support of the mission for the Office of Science and the Office of Biological and Environmental Research (BER), Spectrum Publishers proposes an editorial project to inform and educate minority undergraduate students in the sciences, minority medical students and minority medical residents of the opportunities and challenges available to them as they complete their training. This editorial project will take the form of a 32-page insert in the Journal for Minority Medical Students. The subject matter will be determined by BER based on mission requirements. The material will be compiled, assembled, edited, revised, designed, printed and distributed as a total package with a vast majority of the work performed by our staff. Our objective is to provide the special report without added (and burdensome) work to the BER staff. The 32-page report will be distributed to our readership of 10,000 future scientists and physicians. In addition, we will prepare the insert so that it can also be used by BER as a stand-alone piece and outreach tool. After publication, we will solicit feedback from our readers through our unique Campus Rep Program of students strategically located on campuses across the nation who will provide valuable editorial feedback. This innovative program will give BER a quick read on the effectiveness of its message. The total cost for this mission-related project is only $30,000.00. Based on our earlier experience with DOE, we are confident that this level of funding will be sufficient to develop an effective educational campaign.

59 BASIC BIOLOGICAL SCIENCES↗

Magnetoelectric coupling at metal surfaces

Magnetoelectric coupling allows the magnetic state of a material to be changed by an applied electric field. To date, this phenomenon has mainly been observed in insulating materials such as complex multiferroic oxides. Bulk metallic systems do not exhibit magnetoelectric coupling, because applied electric fields are screened by conduction electrons. We demonstrate strong magnetoelectric coupling at the surface of thin iron films using the electric field from a scanning tunnelling microscope, and are able to write, store and read information to areas with sides of a few nanometres. Our work demonstrates that high-density, non-volatile information storage is possible in metals.

36 MATERIALS SCIENCE↗